    TECHNICAL DATA SHEET PUBLISHED AUGUST 2011

    FLO-GROUT 1General purpose cementitious grout

    PRODUCT FEATURES

    Flo-grout 1is a single pack, high strength, non-shrink,cementitious grout.

    Flo-grout 1 consists of a blend of modied specialcements and ne graded aggregates. It is free fromcorrosive substances and chlorides.

    Flo-grout 1 has excellent ow properties and has apositive expansion during setting. It is designed for gap

    widths of 10 100mm, but may be bulked out for widergaps.

    The expansion and strength properties of Flo-grout 1

    make it ideal for the assembly grouting of machine beds,tracks, crane rails and transformers. The material is alsosuitable for grouting of stanchion bases, struts, railingsand guardrail assemblies

    MATERIALS SUPPLIED

    25 kg paper sacks.

    STORAGE

    Protect from frost and store under dry warehouseconditions at a temperature between 10C and 30C.

    When stored as above, and used within 6 months of thedate shown on the packaging, the activity of the reducingagent added will be maintained and the mixed productwill contain no more than 0.0002% (2ppm) solublechromium (VI) on the total dry weight of the cement.

    SHELF LIFE

    12 months in unopened bags and stored under goodconditions.

    COVERAGEA 25 kg bag using 4.1 litres of clean water will yieldapprox. 13.3 litres.

    SPECIFIED THICKNESS RANGE

    10 100mm in a single layer.

    For greater thicknesses 2 6mm washed and driedpea gravel should be added to the Flo-grout 1 at 1:1

    by weight.

    Typical properties @ 4.1 litres / 25 kg(fowable consistency)

    Compressive strength (N/mm)BS EN 12390-3: 2002 1 Day 3 Days 7 Days 28 Days

    > 15.0> 35.0> 45.0> 60.0

    Maximum particle size / mm 1

    Pourable life @ 20C / minutes 30

    Setting time / minutes Initial set: Final set:

    260320

    Free expansion / % 0.90

    Gap width / mmMaximum ow / mm @ 20C

    150mm head 250mm head

    10 400 10

    20 1000 20

    30 1500 30

    40 2500 40

    50 3000 50

    TECHNICAL INFORMATION

  • 5/28/2018 Flo-grout 1

    2/2

    Don Construction Products Ltd Churnetside Business Park, Station Road,Cheddleton, Leek, Staffs, ST13 7RS, UK T: +44 (0) 1538 361799

    Note:

    We endeavour to ensure that any information, advice or recommendation we may give in product literature is accurate and

    correct. However, because we have no control over where and how products are applied, we cannot accept any liability

    arising from the use of the products.

    www.dcp-int.com

    APPLICATION INSTRUCTIONS

    SURFACE PREPARATION

    The substrate should be sound, clean and free fromcontamination. Concrete and steel surfaces should be

    mechanically etched to ensure good bonding. Removablemetal shims should be lightly coated with suitable release

    oil or grease.

    Pre-soak the concrete surface with clean water for aminimum of 4 hours before grouting. All surplus watermust be removed before grouting.

    MIXING

    The following water additions should be used dependingon the required consistency:

    Flowable: 4.1 litres per 25 kg bag

    Fluid: 4.4 litres per 25 kg bag

    1 - 2 bags of material should be slowly added to themeasured quantity of water whilst mixing using a slowspeed drill and power whisk. Mix for 3 - 5 minutes.Allow to stand for 1 minute before use. Larger quantitiesshould be mixed using a high shear mixer. Do not mix

    more material than can be used in 30 minutes. Do notuse colloidal type mixers.

    APPLICATION

    Flo-grout 1 can be applied normally at temperaturesbetween 5C and 35C.

    Good concreting practice with regard to placing at lowand high temperatures should be observed. For machine

    base plate grouting, ensure that all bolt pockets are xedbefore grouting between substrate and base.

    Continuous grout ow is essential. Sufcient materialmust be available to ensure continuity of the operation.Pouring should be from one side of the base plate toeliminate the entrapment of air. The pouring side should

    be raised by means of a hopper or grout box to maintaina minimum 150mm head of grout at all times.

    For larger applications Flo-grout 1 can be placed bymeans of pumping. The use of a heavy-duty diaphragmpump is suitable for this purpose.

    Please contact our Technical Department for furtheradvice.

    WORKING TIME

    Following mixing, material should be placed within30 minutes to gain the full benet of the expansionsystem.

    CURING

    All exposed surfaces must be adequately cured. The useof Setseal 6curing agent is recommended. Alternativelywet hessian or continuous ne water spray may beused.

    Shuttering should be struck after 24 hours. If the air

    temperature has fallen below 5C, shuttering should beleft in place for at least 36 hours.

    Do not place when the substrate temperature is below5C or when the ambient temperature is 5C andfalling. Protect from frost. Do not exceed the maximum

    recommended water content and only use clean water.

    The use of warm water is recommended at low

    temperatures to accelerate strength development.At elevated temperatures, the use of cold water isrecommended.

    CLEANING

    Wash tools with water immediately after use.

    HEALTH AND SAFETY

    Refer to the product Material Safety Data Sheets beforeusing Flo-grout 1.

    GENERAL GUIDANCE

    This data sheet is for general guidance purposes only andmay contain information that is inappropriate for certainconditions of use. Accordingly, all recommendationsand suggestions are made without guarantee. Furtherinformation is available from our Technical Department.