SAV SystemsProduct Catalogue
www.sav-systems.comRev: 4.0 08/2012
FlatStation HIUs and Energy meters
HVAC Commissioning ModulesDHW and BCW Manifolds
About SAV Systems
SAV has been operating in the UK since 1988.
SAV Systems is a leading provider of innovative building services solutions designed to boost energy efficiency and cut carbon emissions.
Products vary from sophisticated mini-CHP systems to simple water meters, but all are purpose-developed to serve a better internal environment and a greener world.
Used as individual products, or integrated into custom-designed systems, the SAV range makes a perfect partner for low energy technologies from renewables to central plant and even district heating systems.
It’s a full family of choice sourced from some of the world’s leading specialist companies - our Partners in Technology. Product groups cover the full spectrum of modern building services.
www.sav-systems.com
UK CUSTOMER SUPPORT CENTRE SAV Systems, Scandia House, Boundary Road, Woking, Surrey GU21 5BX Telephone: +44 (0)1483 771910 EMAIL: [email protected]
GENERAL INFORMATION: Office Hours: 9.00am - 5.00pm Monday to Friday.
FLATSTATION HIUs
Page
n Overview 4
n 1 Series BS 5
n 1 Series DS fully insulated 6
n 3 Series BS 7
n 3 Series BS Basic 8
n 5 Series BS 9
n 5 Series DS 10
n 5 Series DS fully insulated 11
n 7 Series BS 12
n 7 Series DS 13
n 7 Series DS fully insulated 14
4
n SAV FLATSTATIONS
OverviewUltra-compact SAV FlatStations supply instant hot water in individual dwellingsserved by central plant. It’s a safe, simple, cost-effective solution that’sengineered for high operational reliability. Creating hot water only on demand(just like a combi) maximizes the energy saving potential of a central boiler andmodern multiple heat source technology. Low return temperatures draw themaximum efficiency from condensing boilers, heat pumps and solar panels.
A single 59 kW Module can produce 21 litres of hot water per minute.
Partners in Technology
Termix - Part of the Danfoss Group leads the world in
instantaneous hot water technology – a logical extension of
its internationally renowned range of controls. This technology
makes a perfect synergy with SAV’s modular approach to building services and
enables us to develop solutions for British projects from apartment blocks and
sheltered housing units to schools and hospitals.
www.termix.biz
FAR Rubinetterie S.p.A. has a proud 30 year history in
the design and manufacture of components for heating,
plumbing and sanitary systems.
www.far.eu
The above documents are available for
download by visiting our website at:
www.sav-systems.com
alternatively a printed copy can be
obtained by calling 01483 771910.
FlatStation HIUs Brochure
and Design Guide
Instantaneous Water Heaters
System Benefits
• Designed for low cabon systems - low returntemperatures
• Independent of the energy source – ideal for use with central gas, oil-fired boilers, CHP units, solar energy etc.
• Only three rising pipes required
• Minimum heat loss in circuit
• Enables accurate energy billing for individual apartments
• No hot water storage tank required
• No formation of lime scale in the heat exchanger
• Full heating comfort - and ample hot water on tap
• Minimum space required for installation
• Simple, but efficient design ensures high operational reliability
Literature
5
n SAV FLATSTATIONS - 1 SERIES
SAV FlatStations - 1 Series BS
Instantaneous water heater for flats and single-family houses
Circuit diagram - example
Technical parameters:Nominal pressure: PN 16DH supply temperature: Tmax = 120 °CDCW static pressure: pmin = 0,5 barBrazing material (HEX): Copper
Weight incl. cover: 10 - 12 kg (incl. packing)
Cover: Grey-lacquered steel sheet
Dimensions (mm):Without cover:H 428 x W 312 x D 155 (1-BS-35;40;59)H 468 x W 312 x D 155 (1-BS-75;90)
With cover:H 430 x W 315 x D 165 (1-BS-35;40;59) H 470 x W 315 x D 165 (1-BS-75;90)
Connections:1 Domestic cold water (DCW)2 Domestic hot water (DHW)3 District heating (DH) supply4 District heating (DH) return
Connections sizes:DH + DCW + DHW: G ¾” (ext. thread)
Options:
bar)-
tion set
DHW: Capacity examples, 10°C/50°C
FlatStation typeDHW
CapacitykW
Supply
Primary°C
Return
Primary°C
Pressure loss
PrimarykPa
Flow rate
Secondary l/m
FlatStation typeDHW
Capacity kW
Supply
Primary°C
Return
Primary°C
Pressure loss
PrimarykPa
Flowrate
Secondaryl/m
1-BS-351-BS-40
29.3 60 23.0 20 10.5
1-BS-59
34.7 60 24.4 20 12.438.2 60 25.2 45 13.7 47.1 60 26.8 45 16.937.8 70 20.0 20 13.6 45.1 70 21.3 20 16.252.3 70 22.4 45 18.8 65.6 70 23.8 45 23.5
1-BS-751-BS-90
60 60 23.0 35 21.3 - - - - - -66 60 24.0 45 23.8 - - - - - -80 70 20.3 35 28.8 - - - - - -90 70 21.0 45 32.3 - - - - - -
DHW
DCW
DHsupply
DHreturn
Wall
DHsupply
DHreturn
DHW
DCW
Circ.
1 Series BS – with safety valve
B Plate heat exchanger DHW2 Non-return valve4 Safety valve6 Thermostatic/non-return
valve7 Thermostatic valve21 To be ordered separately
1 Series BS
B Plate heat exchanger DHW7 Thermostatic valve
6
n SAV FLATSTATIONS - 1 SERIES
SAV FlatStations - 1 Series DS Fully Insulated
Instantaneous water heater for flats and single-family houses
B
72
9
Technical data table
Technical parameters:
max
min
Weight incl. cover: (incl. packing)
Cover: Grey full-insulation
Dimensions (mm):
Connections:
3 District heating �ow (DH) 4 District heating return (DH)
Connections sizes:
Options:
bar)-
tion set
(GTU)
DHW: Capacity examples
FlatStation type
Supply �ow
Primary
Return �ow
Primary
Pressure loss
Primary kPa
Tap
13.316.617.721.810.512.614.818
loadl/m
1-DS-351-DS-40
32,3 2040,343 20
24,3 20
41 20
DH supplyDHW
Seen from above
CWM DH return
B Water heater9 Strainer72 IHPT
DHW: Capacity examples
FlatStation type
Supply �ow
Primary
Return �ow
Primary
Pressure loss
Pr imar y kPa
Tap load l/m
1-DS-59
32,3 2222,2 30
20322032
34 23,4 2044 24,1 32
2032
13.315.715.720.120.623.312.315.917.322.2
7
n SAV FLATSTATIONS - 3 SERIES
A Heat exchangerM Electrical wiring box2 Single check valve4 Safety valve7 Thermostatic valve9 Strainer
DHF
DHR
Circuit diagram - example
Technical parameters:Nominal pressure: PN 10*DH supply temperature: Tmax = 120 °CBrazing material (HEX): Copper* PN 16 versions are available on enquiry
Weight incl. cover: 25 kg (incl. packing)
Cover: White-lacquered steel sheet
Dimensions (mm):Without cover:H 750 x W 525 x D 330With cover:H 800 x W 540 x D 430
Connections sizes:DH + HE: G ¾” (int. thread)
Options:White-lacquered steel coverRoom thermostatSensor for DHW cylinder
Heating: Capacity examples
FlatStation typeHeating Capacity
kW
Heating circuitPrimary
°C
Heating circuitSecondary
°C
Pressure lossPrimary
kPa
Flow rateSecondary
l/m
Residualpump head
kPa
3-BS-1015 80/53 50/70 50 10.7 1215 80/41 40/60 30 11.3 128 80/66 65/75 40 12.2 10
3-BS-1520 80/53 50/70 50 15.1 2120 80/41 40/60 35 15.1 2110 80/66 65/75 50 15.2 21
3-BS-2025 80/53 50/70 35 18.9 1625 80/41 40/60 25 18.9 1613 80/66 65/75 35 19.8 13
26 Manometer31 Di�erential pressure controller38 Expansion tank41 Fitting piece, energy meter48 Air escape, manual69 On/o� valve
10 Circulation pump14 Sensor pocket, energy meter18 Thermometer20 Filling/drain valve21 To be ordered separately24 Delivered loose with unit
Cylinder
FL
HFL
HRL
Cylinder
RL
Border of delivery
Connections:
SAV FlatStations - 3 Series BS
Indirect FlatStation for flats and single-family houses
8
n SAV FLATSTATIONS - 3 SERIES
Circuit diagram - example
Technical parameters:
Weight incl. cover:
Cover:
Dimensions (mm):
Connections: Connections sizes:
Options:
1 Ball valve4 Safety valve7 Thermostatic valve9 Strainer
24 Delivered loose with unit26 Manometer31 Differential pressure controller38 Expansion tank
10 Circulator pump14 Sensor pocket, energy meter18 Thermometer20 Filling/drain valve
48 Air escape, manuel69 On/off valve
41 Fitting piece energy meter
1.
1
47
9
910
14
1820
24
264 bar
31 38
18
DHR
DHF
HRL
HFL
A
Heatexchanger41
48
48
48
Wiring BoxElectrical
M
69M
Heating: Capacity examples
FlatStation typeHeatingCapacity
kW
Supply flow
Primary°C
Heating Circuit
°C
Pressure loss
PrimarykPa
Pressure loss
SecondarykPa
Flow rate
Primaryl/m
Flow rate
Secondaryl/m
3-BS-15-B18 70 60/35 25 20 7.4 10.320 80 70/40 25 20 7.2 9.5515 90 80/60 25 20 8.4 10.5
3-BS-30-B30 70 60/35 35 20 12.3 17.234 80 70/40 35 20 12.2 16.328 90 80/60 35 20 15.8 21.3
3-BS-40-B45 70 60/35 45 20 18.4 25.850 80 70/40 45 20 17.9 23.935 90 80/60 45 20 19.7 26.6
SAV FlatStations - 3 Series BS Basic
Heating Only - Indirect FlatStation for flats and single-family houses
9
n SAV FLATSTATIONS - 5 SERIES
SAV FlatStations - 5 Series BS
Direct FlatStation for flats and single family houses
Circuit diagram - example
Technical parameters:Nominal pressure: PN 10DH supply temperature: Tmax = 120 °CDCW static pressure: pmin = 0,5 barBrazing material (HEX): Copper
Weight incl. cover: 20 kg (incl. packing)
Cover: White- lacquered steel sheet
Dimensions (mm):Without cover:H 760 x W 525 x D 110 (150) mmWith cover (mount on wall variant):H 800 x W 540 x D 242 mm
Connections:1 District heating (DH) supply2 District heating (DH) return3 Domestic hot water (DHW)4 Domestic cold water (DCW)5 Heating (HE) supply 6 Heating (HE) return
Connections sizes:DH + HE: G ¾” (int. thread) DCW + DHW: G ¾” (int. thread)
Options:
(on the wall)
circulation set
DHW: Capacity examples
type
DHW Capacity
kWPrimary
°CPrimary
°C
DCW / DHW°C
Pressure lossPrimary
kPa
Flow rate
l/m33 60 20 10/45 25 13.540 70 20 10/50 25 15.150 60 20 10/45 40 20.558 70 20 10/50 40 20.865 60 20 10/45 35 26.675 70 20 10/50 3568 60 20 10/45 30 27.685 70 20 10/50 30 28.7
B Water heater1 Ball valve2A Single check valve, WRAS7 Thermostatic valve9 Strainer14 Sensor pocket, energy meter31 Di�erential pressure controller41 Fitting piece, energy meter69 On / o� valve
10
n SAV FLATSTATIONS - 5 SERIES
SAV FlatStations - 5 Series DS
Direct FlatStation for flats and single family houses
Circuit diagram - example
Technical parameters:Nominal pressure: PN 10DH supply temperature: Tmax = 120 °CDCW static pressure: pmin = 1 barBrazing material (HEX): CopperMax pri. di�. pressure Pmax = 6 barDHW setting range: T = 45-65 °C
Weight incl. cover: 20 kg (incl. packing)
Cover: White-lacquered steel sheet
Dimensions (mm):Without coverH 510 x W 528 x D 240 With cover (mounted on wall variant)H 550 x W 540 x D 360
Connections:1 District heating (DH) supply2 District heating (DH) return3 Domestic hot water (DHW)4 Domestic cold water (DCW) 5 Heating (HE) supply6 Heating (HE) return
Connections sizes:DH + HE: G ¾” (int. thread) DCW + DHW: G ¾” (int. thread)
Options:Mounting rail with ball valvesWhite-lacquered stainless steel cover (on the wall)Safety valve (10 bar)Safety valve with thermostatic circulation setThermostatic circulation setPressure compensation valve (GTU)Room thermostatThermometerBall valves
DHW: Capacity examples
FlatStationtype
DHW Capacity
kW
Supply �ow
Primary°C
Return �ow
primary °C
DHW °C
Pressure loss
Primary kPa*
DHW Tap load
l/m
5-DS-35-10-C5-DS-40-10-C
32,3 60 19 10/45 22 13.340,3 60 20 10/45 32 16.636,5 70 18 10/50 20 13.255 70 21 10/50 39 19.8
5-DS-59-10-C
32,3 55 19 10/45 22 13.338 55 20 10/45 30 15.7
32,3 60 16 10/45 18 13.347 60 18 10/45 32 19.4
39,5 70 16 10/50 20 14.359 70 19 10/50 33 21.3
Front view Side view
Heating: Capacity examples
HeatingCapacity
kW
HeatingCircuit ∆t
°C
Pressureloss*kPa
Flow ratel/m
10 20 25 7.25-DS-xx-10-C 10 30 25 4.8
15 30 25 7.2
FlatStationtype
Non-standard sizes available on request
11
n SAV FLATSTATIONS - 5 SERIES
SAV FlatStations - 5 Series DS Fully Insulated
Direct FlatStation for flats and single family houses
Circuit diagram - example
Technical parameters:Nominal pressure: PN 10DH supply temperature: Tmax = 120 °CDCW static pressure: p min = 1 barBrazing material (HEX): CopperMax pri.
Weight incl. cover:
Insulation cover:
Dimensions (mm):
Connections: Connections sizes:
Options:
B Heat exchangerM Electrical wiring box2A Single check valve, WRAS 2C Single check valve incl. circulation pipe9 Strainer14 Sensor pocket, energy meter21 To be ordered separately31 41 Fitting piece, energy meter ¾” x 110 mm63 Sieve69 72 TPV
DHW
HWC
DHsupply
DHreturn
HEsupply
HEreturn
DCW
DHW: Capacity examples Heating: Capacity examples
MountingrailOption
528
100 180 60
70
560
518
1 2 3 4
5 6
45
255
12
n SAV FLATSTATIONS - 7 SERIES
SAV FlatStations - 7 Series BS
Indirect flatstation for flats and single family houses
Electrical wiring box
24
Connections sizes: G ¾” (int. thread)
Circuit diagram - example
Technical parameters:Nominal pressure: PN 10*DH supply temperature: Tmax = 120 °CDCW static pressure: pmin = 0,5 barBrazing material (HEX): Copper* PN 16 versions are available on enquiry
Weight incl. cover: 35 kg (incl. packing)
Cover: White- lacquered steel
Dimensions (mm):Without cover:H 810 x W 525 x D 360With cover:H 800 x W 540 x D 430
9 Strainer10 Circulation pump14 Sensor pocket, heat meter18 Thermometer20 Filling/drain valve24 Delivered loose with unit26 Manometer31 Di�erential pressure controller38 Expansion vessel41 Fitting piece, heat meter48 Air escape, manual69 On / o� valve
Connections:1 District heating (DH) supply2 District heating (DH) return3 Domestic hot water (DHW)4 Domestic cold water (DCW)5 Heating (HE) supply6 Heating (HE) return
DHW: Capacity examples, 10°C/50°C Heating: Capacity examples
FlatStationtype
DHWCapacity
kW
SupplyflowPri.°C
ReturnflowPri.°C
DHW/DCW
°C
Pressure lossPri.*kPa
DHW Tap loadl/m
FlatStationtype
HeatingCapacity
kW
Supply flow Pri.
°C
Heatingcircuit
°C
PressurelossPri.*kPa
PressurelossSec.kPa
FlowratePri.l/m
FlowrateSec.l/m
Available pump
pressureSec.kPa
7-BS-35-xx
7-BS-40-xx33 60 19 10/45 25 13.9
7-BS-xx-105 80 35/25 10 15 1.4 7.5 20
41 70 19 10/50 25 15.2 18 80 70/40 40 20 8.3 9.1 15
7-BS-59-xx50 60 21 10/45 40 21.2 20 90 70/40 30 20 6.5 10 1560 70 21 10/50 35 22.2
7-BS-xx-209 80 35/25 10 15 2.5 13.5 30
7-BS-75-xx60 60 20 10/45 30 25.3 29 80 70/40 40 15 12.9 14.6 3075 70 20 10/50 30 27.8 33 90 70/40 30 20 10.6 16.6 25
7-BS-xx-4013 80 35/25 10 15 3.6 19.5 2546 80 70/40 35 20 20.6 23.1 1550 90 70/40 25 20 16.1 25.1 15
A Plate heat exchanger HEB Water heater1 Ball valve2A Single check valve, WRAS2B Double check valve, WRAS4 Safety valve6 Thermostatic/non-return
valve7 Thermostatic valve
DHW
DCW
DHsupply
DHreturn
HEsupply
HEreturn
* Heat meter not included
Options:
Jacob Jensen)
safety valve discharge piping
check valve
heating
controls
circuit
13
n SAV FLATSTATIONS - 7 SERIES
SAV FlatStations - 7 Series DS
Indirect FlatStation for flats and single family houses
Circuit diagram - example
Technical parameters:Nominal pressure: PN 10*DH supply temperature: Tmax = 120 °CDCW static pressure: pmin = 1 barBrazing material (HEX): Copper* PN 16 versions are available on enquiry
Max pri. di�. pressure: Pmax = 6 barDHW setting range: T = 45-65 °C
Weight incl. cover: 29 kg (incl. packing)
Cover: White-lacquered steel sheet
Dimensions (mm):Without cover:H 750 x W 528 x D 420With cover:H 800 x W 540 x D 430
H 800 x W 540 x D 385H 650 x W 425 x D 420
Alternative dimensions (with hook-on cover):
Connections:1 District heating (DH) supply2 District heating (DH) return3 Domestic hot water (DHW)4 Domestic cold water (DCW)5 Heating (HE) supply6 Heating (HE) return
Connections sizes:All connections: G ¾” (int. thread)
Options:Booster pump (increases DH �ow)Separate mixing circuitWhite-lacquered steel coverSafety valve (10 bar)Safety valve with thermostatic circulation setThermostatic circulation setPressure compensation valve (GTU)Electronic controllerRoom thermostatConnection for circulation
DHW: Capacity examples
FlatStationtype
DHW Capacity
kW
Supply/Return �ow
primary °C
DHW °C
Pressure loss
Primary kPa*
DHW Tap load
l/min
7-DS-35-xx-C7-DS-40-xx-C
32,3 60/19,8 10/45 23 13.340,3 60/20,7 10/45 33 16.636,5 70/19,1 10/50 20 13.255 70/21,5 10/50 39 19.9
7-DS-59-xx-C
32,3 55/21,9 10/45 26 13.338 55/22,2 10/45 34 15.7
32,3 60/19,6 10/45 20 13.347 60/19,6 10/45 34 19.4
39,5 70/19 10/50 20 14.359 70/19,2 10/50 34 21.3
Side viewFront view
Heating: Capacity examples
FlatSta-tiontype
HeatingCapacity
kW
Supply / Return �ow pri-
mary °C
Heating circuit
°C
Flow rate
primary l/min
dp min kPa
Flow rate secon-dary l/min
Residual pump
head kPa
7-DS-xx-12-C12 70/40 60/35 5.9 30 7.0 2524 90/45 70/40 7.8 45 11.7 20
7-DS-xx-20-C19 70/40 60/35 9.2 30 11.0 3535 90/45 70/40 11.2 45 17.0 20
7-DS-xx-35-C31 70/40 60/35 15.1 30 18.0 2550 90/45 70/40 15.9 45 24.3 15
* Heat meter not included
14
n SAV FLATSTATIONS - 7 SERIES
SAV FlatStations - 7 Series DS Fully Insulated
Indirect flatstation for flats and single family houses
Circuit diagram - example
Technical parameters:
Weight incl. cover:
Insulation:
Dimensions (mm):
2B Single check valve, WRAS2C Double check valve, WRAS 4 Safety valve7 Thermostatic valve9 Strainer10 Circulation pump14 Sensor pocket, heat meter20 Filling/drain valve21 To be ordered separately24 Delivered loose with unit26 Manometer31
controller38 Expansion vessel41 Fitting piece, energy meter48 Air escape, manual63 Sieve69 72 TPV valve
Connections: Connections sizes:
Options:
DHW: Capacity examples
A Plate heat exchanger HEB Plate heat exchanger DHWM Electrical wiring box1 Ball valve2A Single check valve incl.
circulation pipe
DHW
DCW
Circ.
DHsupply
DHreturn
HEsupply
HEreturn
Heating: Capacity examples
DHW & BCW MANIFOLDS
Page
n DHW & BCW Manifolds 16
n Community Heating Solutions 20
16
n DHW & BCW MANIFOLDS
DOMESTIC HOT WATER AND BOOSTED COLD WATER
Description:
Domestic Hot & cold
CODE:
SAV FloCon - 940
PAGE
17
PAGE
17
PAGE
18
PAGE
18
PAGE
19
Description:
Domestic Hot or Cold manifold
CODE:
SAV FloCon - 937
Description:
Single port Branch manifold with either
Hot or Cold water meter & PRV
CODE:
SAV FloCon - 850
Description:
Multi port Branch manifold with either
Hot or cold water meter & PRV
CODE:
SAV FloCon - 852
Description:
Domestic manifold assembly with
mixer valve
CODE:
SAV FloCon - 144
17
n DHW & BCW MANIFOLDS& $ $ $ $ $$$ $!
++,-.$"+/$"01$(%'%+ 231-+'+!
SAV FloCon - 940/937 - Domestic hot and cold manifold assemblies
! ! !
!
Dimension table
Ports Manifold 20-mm
Manifold 25-mm
Manifold 32 mm
A B A B A B
2 230 97 252 101 328 118
3 275 97 297 101 373 118
4 320 97 342 101 418 118
5 365 97 387 101 463 118
6 410 97 432 101 508 118
Note: Manifold assemblies are available with larger port allocations and for 40 & 50-mm systems on request
Dimension tolerances are ± 5-mm
!! !
Technical Data
! ! ! 20-mm 25-mm 32-mm Manifold Port flow See graph below Manifold Material DZR Brass Manifold Suitability Domestic and heating systems Centre between ports 45-mm 45-mm 70-mm Maximum operating pressure 10 bar 10 bar 10 bar Maximum operating temperature 95 "C 95 "C 95 "C
!
Manifold Flow Characteristics
20 & 25-mm manifold 32-mm Manifold
! !!
18
n DHW & BCW MANIFOLDS! ! ! ! ! !
!
++,-.$"+/$"01$(%'%+ 231-+'+!
SAV FloCon - 850 - Branch Manifold Assembly
BBrraanncchh mmaannii ffoo llddss ccaann bbee ssuuppppll ii eedd ffoorr ssiinnggllee aanndd oorr mmuull tt ii ppoorr tt hhoott oorr ccoolldd wwaatteerr aappppll ii ccaatt iioonnss.. TThhee ssyysstteemm mmaakkeess pprroovv ii ssiioonn ffoorr eeii tthheerr ssiinnggllee oorr ddoouubbllee cchheecckk vvaall vvee aappppll ii ccaatt iioonnss ffoorr uussee wwii tthh SSAAVV ssttaannddaarrdd wwaatteerr mmeetteerrss oorr CCll iieenntt ssuuppppll ii eedd FFrreeee ii ssssuuee mmeetteerrss
Dimension table
Ports Manifold 32-mm Manifold 40-mm Manifold 50-mm AA BB AA BB AA BB MMeetteerr 1155--mmmm MMeetteerr 2200--mmmm MMeetteerr 2255--mmmm
11 663300 -- 665500 -- -- -- 22 661155 227755 771188 330000 880000 331100 33 771155 227755 881188 330000 990000 331100 44 881155 227755 991188 330000 11000000 331100 55 991155 227755 11001188 330000 11110000 331100
Note: MMaanniiffoolldd aasssseemmbbll iieess aarree aavvaaii llaabbllee wwiitthh llaarrggeerr ppoorrtt aall llooccaattiioonnss.. DDiimmeennssiioonn BB iiss bbaasseedd oonn SSAAVV ssttaannddaarrdd wwaatteerr mmeettrreess.. WWhheerree ffrreeee iissssuuee mmeetteerrss aarree ttoo bbee pprroovviiddeedd aa ssppaacceerr ppiieeccee wwii ll ll bbee ff iitttteedd bbaasseedd oonn CCll iieennttss ssppeecciiff iiccaattiioonn.. IIff ssoo
rreeqquuiirreedd,, SSAAVV ccaann ff iitt tthhee ffrreeee iissssuuee wwaatteerr mmeetteerr bbuutt ddooeess nnoott aacccceepptt rreessppoonnssiibbii ll ii ttyy ffoorr nnoonn SSAAVV eeqquuiippmmeenntt ff iitttteedd
Technical Data
Reference Manifold 32-mm Manifold 40-mm Manifold 50-mm
11 IIVV 3322--mmmm ++ sstt rraaiinneerr IIVV 4400--mmmm ++ sstt rraaiinneerr IIVV 5500--mmmm ++ sstt rraaiinneerr
22 PPRRVV DDNN--3322 11 ttoo 66 bbaarr
MMaatteerr iiaall DDZZRR BBrraassss WWoorrkkiinngg tteemmppeerraattuurree 77550CC
PPRRVV DDNN--4400 11 ttoo 66 bbaarr MMaatteerr iiaall DDZZRR BBrraassss
WWoorrkkiinngg tteemmppeerraattuurree 77550CC
PPRRVV DDNN--5500 11 ttoo 66 bbaarr MMaatteerr iiaall DDZZRR BBrraassss
WWoorrkkiinngg tteemmppeerraattuurree 77550CC 33 SSttaarr tt MMaannii ffoo lldd 3322--mmmm SSttaarr tt MMaannii ffoo lldd 4400--mmmm SSttaarr tt MMaannii ffoo lldd 5500--mmmm
44 CChheecckk VVaall vvee ((OOpptt iioonnaall )) CChheecckk VVaall vvee ((OOpptt iioonnaall )) CChheecckk VVaall vvee ((OOpptt iioonnaall ))
55 -- 66 DDNN--1155 IIVV wwii tthh iinntteeggrraatteedd cchheecckk vvaall vvee aanndd ddrraaiinn ppooiinntt
DDNN--2200 IIVV wwii tthh iinntteeggrraatteedd cchheecckk vvaall vvee aanndd ddrraaiinn ppooiinntt
DDNN--2255 IIVV wwii tthh iinntteeggrraatteedd cchheecckk vvaall vvee aanndd ddrraaiinn ppooiinntt
77 1155--mmmm HHoott oorr ccoolldd wwaatteerr mmeetteerr CCllaassss BB
2200--mmmm HHoott oorr ccoolldd wwaatteerr mmeetteerr CCllaassss BB
2255--mmmm HHoott oorr ccoolldd wwaatteerr mmeetteerr CCllaassss BB
PPoorr tt ssppaacc iinngg SSttaannddaarrdd ddiissttaannccee bbeettwweeeenn ppoorrttss iiss 110000--mmmm.. 220000--mmmm ssppaacciinngg ccaann bbee pprroovviiddeedd iiff rreeqquuiirreedd
19
n DHW & BCW MANIFOLDS
! ! ! ! ! !
! ,,-./$",,)$"01$(%'%, 231.,',!
SAV FloCon - 144 - Mixer Valve manifold assembly
Dimension Table
Ports Manifold 20-mm Manifold 25-mm
AA BB CC DD AA BB CC DD
22 336655 335500 338800 336600
33 441100 339955 442255 440055
44 445555 444400 447700 445500
55 550000 448855 551155 449955
66 554455 553300
119900 221100
556600 554400
225500 222255
TThhee aabboovvee mmaannii ffoo lldd AAsssseemmbbllyy ii ss aavvaaii ll aabbllee iinn dd ii ff ffeerreenntt ppoorr tt ccoonnff iigguurraatt iioonnss..
Technical Data
MMaannii ffoo lldd SSii zzee DDNN--2200 oorr DDNN--2255
MMaannii ffoo lldd MMaatteerr iiaall DDZZRR BBrraassss
MMaannii ffoo lldd ssuu ii ttaabbii ll ii ttyy DDoommeesstt ii cc
CCeenntt rreess bbeettwweeeenn ppoorr tt ss 4455--mmmm
MMaaxx ooppeerraatt iinngg pprreessssuurree 66 bbaarr
TThheerrmmoossttaatt ii cc mmiixxeerr MMaaxx iinnppuutt tteemmppeerraattuurree 9955 0CC SSeett tt iinngg rraannggee 2277 –– 6655 0CC
20
n COMMUNITY HEATING SOLUTIONS
COMMUNITY HEATING SOLUTIONS
PAGE
Datasheetcoming soon
PAGE
21
PAGE
23
Description:
DHW & Heating flow manifold assembly
with motorised 2-Port valve, energy
meter.
CODE:
SAV FloCon - 1158
Description:
Hot and cold branch manifold
assemblies with energy meter in
insulated enclosure
CODE:
SAV FloCon - 992
PAGE
22
Description:
Heating differential By-Pass Assembly
CODE:
SAV FloCon - 986
Description:
FlatStation with UFH manifold assembly
and Hot & cold water manifold
CODE:
SAV FloCon - 969
! ! ! ! ! !!
+ + + + + +!
SAV FloCon - 992 – PHE/UFH/Hot-Cold water combination
Features
This combination of Hot and cold water meters is housed in an insulated galvanised sheet steel
enclosure and includes an energy meter to monitor energy usage. The enclosure is
provided with a removable lid with quick release clips to ensure good sealing.
The hot water meter circuit includes a LockShield bypass control valve to provide
trickle flow.
Each Water meter circuit comprises of: IV DN-20 with strainer
PRV DN-20 IV DN-20
Water meter DN-20 IV DN-20 with Drain & NRV
Technical Data
Hot / Cold water Meter DN-20
Max flow 0.29 l/sec
Assembly suitability Hot/Cold water metering Class B
Maximum operating pressure 10 bar
Maximum operating temperature 95 "C
Water pump characteristics
21
n COMMUNITY HEATING SOLUTIONS
22
n COMMUNITY HEATING SOLUTIONS! ! ! ! ! !
!
, , , , ,!
SAV FloCon - 986 – Heating differential by-pass assembly
Technical Data
Features
Designed for apartment block heating, district heating plants and central heating systems the By-pass assembly has a self-acting differential pressure relief controller designed to open on rising differential pressure. The controller has a control valve, an actuator with one control diaphragm and handle for differential pressure setting.
By-pass assembly DN-32
Differential Pressure controller DN-15
Controller setting range 0.1 - 1.2 bar
Temperature - Circulation water / glycolic
water up to 30%: -25 … 130 °C
23
n COMMUNITY HEATING SOLUTIONS! ! ! ! ! !
!
* **(.$"/0$(%'%* 120,*'*!
SAV FloCon - 969 – PHE/UFH/Hot-Cold water combination
Technical Data
MMaaxxiimmuumm ooppeerraattiinngg pprreessssuurree 1100 bbaarr
MMaaxxiimmuumm ooppeerraattiinngg tteemmppeerraattuurree 9955 1CC
Approximate Weight
FFrraammee 1155 kkgg
HHoott--CCoolldd mmaanniiffoollddss ((44--PPoorrtt)) 44 kkgg
FFllaattSSttaattiioonn SSeerriieess 55 2200 kkgg
Flat Station Series 7 3355 jjgg
UUFFHH ((66 PPoorrtt)) 1155 kkgg
Space Requirement
(For full dimensions see relevant data sheet) Height Depth Frame Width
Manifold
22 ttoo 66 ppoorrtt HHoott--CCoolldd MMaanniiffoolldd aassssyy 227700 222200
MMaanniiffoolldd DDNN--2200
LLaarrggeerr mmaanniiffoolldd ssiizzeess aavvaaiiaabbllee oonn rreeqquueesstt DDiissttaannccee bbeettwweeeenn ppoorrttss
4455--mmmm
Determined by FlatStation width. IInn ccaasseess wwhheerree tthhee ppoorrtt rreeqquuiirreemmeenntt eexxcceeeeddss tthhee
aavvaaii llaabbllee wwiiddtthh aann aalltteerrnnaattiivvee ddeessiiggnn ccaann bbee ccoonnssiiddeerreedd
PHE
SSeerriieess 55 880000 330000 554400
SSeerriieess 77 880000 448800 554400
UFH
22 ttoo 77 ppoorrtt UUFFHH mmaanniiffoolldd aasssseemmbbllyy 880000 119900
Determined by Flat Station wwiiddtthh.. IInn ccaasseess wwhheerree tthhee ppoorrtt rreeqquuiirreemmeenntt eexxcceeeeddss aavvaaii llaabbllee
wwiiddtthh aann aalltteerrnnaattiivvee ddeessiiggnn ccaann bbee ccoonnssiiddeerreedd
HVAC COMMISSIONING MODULES
Page
n HVAC Commissioning Modules 26
26
n HVAC COMMISSIONING MODULES
PASSIVE
Description:
Heating - Radiant Panels
CODE:
876
Description:
Heating - Radiators
CODE:
840
Description:
UFH with Pump Kit
CODE:
501
PAGE
27
PAGE
28
PAGE
29
27
n HVAC COMMISSIONING MODULES& % % % %%% %!
++,-.$"++'%$"/0$(%'%+ 120-+'+!
SAV FloCon - 876 - Heating / Radiant panel Manifold assemblies
Dimension table
Ports Manifold 20-mm Manifold 25-mm
AA BB AA BB
22 223300 225522
33 227755 229977
44 332200 334422
55 336655 338877
66 441100
7700
443322
8800
NNoottee:: MMaanniiffoolldd aasssseemmbbll iieess aarree aavvaaii llaabbllee wwiitthh llaarrggeerr ppoorrtt aall llooccaattiioonnss oonn rreeqquueesstt
Technical Data
MMaannii ffoo lldd SSii zzee 2200--mmmm 2255--mmmm MMaannii ffoo lldd PPoorr tt ff llooww SSeeee ggrraapphh bbeellooww MMaannii ffoo lldd MMaatteerr iiaall BBrraassss MMaannii ffoo lldd FF llooww --MMuull tt ii FFaarr RReettuurrnn -- LLoocckkSShhiieelldd CCeenntt rree bbeettwweeeenn ppoorr tt ss 4455--mmmm 4455--mmmm MMaaxx iimmuumm ooppeerraatt iinngg pprreessssuurree 1100 bbaarr 1100 bbaarr MMaaxx iimmuumm ooppeerraatt iinngg tteemmppeerraattuurree 9955 3CC 9955 3CC
Manifold Flow Characteristics
FAR MultiFar manifold
FAR balancing manifold
28
n HVAC COMMISSIONING MODULES! ! ! ! !
!
,,-./$",0$"12$(%'%, 342.,',!
SAV FloCon - 840 – Radiator Heating Manifold
Dimension table
Ports Manifold 25-mm
Manifold 32-mm
AA BB AA BB
22 ttoo 44 660000 660000
55 ttoo 88 880000 880000
221100
225500
NNoottee:: MMaanniiffoolldd aasssseemmbbll iieess aarree aavvaaii llaabbllee wwiitthh llaarrggeerr ppoorrtt aall llooccaattiioonnss oonn rreeqquueesstt..
Technical Data
Manifold 25-mm Manifold 32-mm
FFeeaattuurreess
SSttaannddaarrdd mmaannii ffoo lldd aasssseemmbbll iieess aarree ff ii tt tteedd wwii tthh aann IIVV oonn tthhee ff llooww aanndd aa CCoommmmiissssiioonniinngg sseett wwii tthh ff llooww sstt rraaiinneerr oonn tthhee rreettuurrnn.. AA bbyy--ppaassss vvaall vvee,, DDOOCC &&
AAAAVV oonn tthhee FF llooww aanndd MMAAVV && ddrraaiinn oonn tthhee rreettuurrnn ii ss pprroovv iiddeedd ffoorr ff lluusshhiinngg aanndd vveenntt iinngg.. DDii ff ffeerreenntt ccoommbbiinnaatt iioonnss ttoo ssuu ii tt ssyysstteemm rreeqquuii rreemmeennttss aarree aavvaaii ll aabbllee oonn
rreeqquueesstt .. MMaannii ffoo lldd PPoorr tt ff llooww SSeeee FF llooww cchhaarr tt ss bbeellooww
MMaaxx mmaannii ffoo lldd ff llooww 00..5544 ll //sseecc 11..1122 ll //sseecc
MMaannii ffoo lldd ssuu ii ttaabbii ll ii ttyy HHeeaatt iinngg
CCeenntt rreess bbeettwweeeenn ppoorr tt ss 4455 -- mmmm 7700 -- mmmm
MMaaxx iimmuumm ooppeerraatt iinngg pprreessssuurree 1100 bbaarr 1100 bbaarr MMaaxx iimmuumm ooppeerraatt iinngg
tteemmppeerraattuurree 9955 4CC 9955 4CC
Manifold Flow Characteristics
2255––mmmm MMaannii ffoo lldd 3322--mmmm MMaannii ffoo lldd
29
n HVAC COMMISSIONING MODULES! ! ! ! !
!
+ + + + +!
SAV FloCon - 501 – UFH Heating Manifold
TThhee UUFFHH ssyysstteemm ii ss ddeessiiggnneedd ffoorr ccoonnnneecctt iioonn ttoo aa pprr iimmaarryy ff llooww && rreettuurrnn.. AA sseeccoonnddaarryy cc ii rrccuullaattoorr ttoo eeff ffeecctt ii vveell yy dd ii sstt rr iibbuuttee aa sseett wwaatteerr tteemmppeerraattuurree ccaann bbee pprroovv iiddeedd ii ff rreeqquuii rreedd.. TThhee ssyysstteemm tteemmppeerraattuurree ii ss ccoonntt rroo ll ll eedd bbyy aa tthheerrmmoossttaatt ii cc mmiixxeerr ttoo bb lleenndd wwaatteerr ff rroomm tthhee rreettuurrnn cc ii rrccuuii tt wwii tthh hhoott wwaatteerr ff rroomm tthhee bbooii lleerr .. AA sseeccuurr ii ttyy tthheerrmmoossttaatt oonn tthhee ff llooww eennssuurreess tthhaatt eexxcceessssii vveell yy hh iigghh tteemmppeerraattuurree wwaatteerr ccaannnnoott eenntteerr tthhee ssyysstteemm sshhoouulldd tthhee mmiixxeerr vvaall vvee ffaaii ll .. TToo eennhhaannccee ccoonntt rroo ll aann eelleecctt rroonniicc CCoonntt rroo ll ll eerr ffoorr tthheerrmmoossttaatt ii cc ccoonntt rroo ll ooff tthhee ppoorr tt oouutt lleettss aanndd bbooii ll eerr ccoonntt rroo ll ccaann bbee pprroovv iiddeedd..
Dimensions
PPoorrttss 22 33 44 55 66
DDiimmeennssiioonn AA 115500 220000 225500 330000 335500
NNoottee:: MMaanniiffoolldd aasssseemmbbll iieess aarree aavvaaii llaabbllee wwiitthh llaarrggeerr ppoorrtt aall llooccaattiioonnss oonn rreeqquueesstt
Technical Data MMaannii ffoo lldd 2255--mmmm
MMaannii ffoo lldd PPoorr tt ff llooww SSeeee FF llooww cchhaarr tt ss bbeellooww
MMaaxx mmaannii ffoo lldd ff llooww 00..5544 ll //sseecc
MMaannii ffoo lldd ssuu ii ttaabbii ll ii ttyy UUnnddeerr FF lloooorr HHeeaatt iinngg
CCeenntt rreess bbeettwweeeenn ppoorr tt ss 5500 -- mmmm
MMaaxx iimmuumm ooppeerraatt iinngg pprreessssuurree 1100 bbaarr MMaaxx iimmuumm ooppeerraatt iinngg
tteemmppeerraattuurree 9955 4CC
Manifold Flow Characteristics 2255––mmmm MMaannii ffoo lldd GGrruunnddffooss ppuummpp AAllpphhaa == 1155 6600
31
ENERGY METERING SYSTEMS
Page
n Overview 32
n WatchMan™ Software 33
n Prepayment Systems 34
n Energy Meters 35
n Data Loggers & Accessories 36
n Wireless Meter Reading 37
n Communication Options 37
n Water Meters 38
32
nWatchMan™ METERING AND MONITORING SYSTEMS
OverviewSAV Watchman metering and monitoring systems provide a low cost solution to building energy monitoring and management.
Energy is commonly wasted in buildings due to poor system operation e.g. heating systems that overheat the building,lights that are left switched on, hot water that is generated but never used, excessive flow temperatures etc. It is notunknown for such losses to account for up to 50% of a building's energy costs. In most cases, this wastage occursbecause it is not cost effective to pay someone to monitor and manage energy usage.
SAV's Watchman system is available in three formats. WatchMan Billing produces individual tenant invoices, automatically,on a monthly basis, WatchMan aM&T gives full energy reporting and targeting as well as an individual tenant invoicesand WatchMan Loadtracker gives 'real time' feedback on the status of the SAV CHP central plant system.
System Benefits
• Operators can view the data in the “big picture” of a whole building and at micro level in relation to an individual apartment.
• Automated meter reading combined with Watchman softwarecollects and validates the data. Data that needs special attentionis automatically “quarantined” before further processing.
• Validated data is automatically analysed. Checks ensure that thebuildings are functioning in an energy- efficient way,consumption data is controlled against budgets, and benchmarksare made between comparable buildings.
• Areas where efficiency doesn’t meet the expected are identified,and problems analysed by drilling down into the data.
• Accurate data leads easily to accurateenergy bills. All relevant information issent on to a billing system, whereinvoices are created.
Partner in Technology
The WatchMan team partners SAV Systems with NRGi of
Denmark, combining proven skills in systems engineering
with Europe’s finest energy management software and
systems support.
NRGi is now recognized as the leading Danish “Carbon
Consultant”. Its specialist divisions span the complete
range of energy solutions - from district heating schemes to biomass fuels,
from building energy management systems to low energy white goods.
The company is a front runner in developing systems and services that save energy
and cut CO2 emissions.
www.nrgi.dk
WatchMan Brochure
aM&T Design Guide
The above documents are available for
download by visiting our website at:
www.sav-systems.com
alternatively a printed copy can be
obtained by calling 020 8979 4153.
Literature
Building services metering hardware and monitoring targetting software
33
nWatchMan™ SOFTWARE
WatchMan™ BillingA simple yet powerful software billing package. Hosted by the SAV servers,access is gained via any internet connection using your own username andpassword. Once online any meter connected to the system, electricity, gas, water, energy etc can be seen and read, dating right back to when the system first became live. The meter usage can be viewed in tabular or graphical format. Manual readings can be added onto the system if required.
Each month a full set of tenant bills are automatically generated and sent via email to a designated address.
WatchMan™ aM&TBuilding on the Watchman Billing package, Watchman aM&T (automaticmonitoring and targeting) adds sophisticated energy monitoring andanalysis. The energy monitoring package increases the flexibility, strengthand energy saving capability of the Watchman software. Customisableenergy reports are the cornerstone of the aM&T system allowing the user to view the energy use and set budgets but importantly to also comparevalues between months, apartments, buildings, benchmarks etc.
The software allows for individually taylored bills or invoices to beconfigured. The invoice can include bespoke payment and address details and can also include company logo's and other additional bespokeinformation. Once configured, the software automatically generates a full set of tenant bills each month or quarter, as required, and can then email them to a designated address.
CO2 consumption can also be detailed and compared against target or budget.
The software also allows for alarms to be created and configured by the user. The alarms can take the form of an email or text message and canbe assigned to different personnel. The alarms can take many forms, as anexample, the software could raise an alarm should a daily maximum flowrate be exceeded, potentially indicating a leak. Alternatively an alarm couldbe triggered if the temperature of the primary flow drops, suggesting that the boilers have tripped etc. Often you’ll know of a problem beforeyour tenants!
WatchMan™ LoadTrackerFor more information, please see our LoadTracker literature.
Mr A B S AMpleSAMple StreetSAMple t ownAB1 2CD
Block H
Moving Home? Call us on 0845 270 7008 up to 7 days before you move with your account number, meter reading and new address.
66761 421
Scottish power energy r etail l td. r egistered o !ce: 1 Atlantic Quay Glasgow G2 8S p.r egistered in Scotland n o 190287. VA t n o GB 659 3720 08.
Date: 07/07/09
package: Standard*
Before you contact us
Please have your meter readings ready before telephoning our customer services centre.
t el n o: 0845 7 292 292
w e may record calls for security and training purposes. w e are open Monday to Friday 8am - 7pm, Saturday 9am - 1pm.
w eb Site: www.scottishpower.co.uk
email: [email protected]
Your electricity number is:
S 01 801 00310 1304 6870 062
Any additional supply numbers are shown overleaf.
Account Number: 1234 5678 100For period: 9/03/09 to 01/07/09
Your electricity charges £153.67
Your energy charges £137.24
Your water charges -£10.62
VAT £13.87
Your total now due is £291.29
please see the reverse of this page for a full breakdown of your charges.
This amount is now due for payment.
Thankyou for being a ScottishPower customer.
t his is not a tax invoice.
Pay now and save!
You could receive a discount of up to £37.50 on your next gas and electricity bill if you pay within 10 days of the date above. Thats a saving of £150 a year for paying your bill on time!
pay your bill quickly and easily at www.scottishpower.co.uk or by calling our self-service Debit Card payment line on 0845 270 0162 with your account number, and card details. Any prompt payer discount will appear on the next bill that you receive.
r eference (Account n umber)
1234 5678 100
r BS Collection Account
12-34-56
Credit Account number
123 4560
Amount due n o fee payable at po counter
£291.29Cheque acceptable at po counter
CASH
CHeQU eS
£
158 208
24
Cashier’s stamp and initials
Signature
Date
Mr A B S AMpleSAMple StreetSAMple t ownAB1 2CD
Please do not write or mark below this line or fold this counterfoil
SAIC
Ltd
013
55 8
4500
Bank Giro Credit
n PREPAYMENT SYSTEMS
34
Prepayment Systems
SAV offers a prepayment system for Pay-As-You-Go heating and hotwater for domestic properties. The tenant has a discrete prepaymentcard reader installed within their apartment which displays theirremaining credit and their meter reading. The display unitcommunicates wirelessly with a prepayment unit fitted to the heatingnetwork. The prepayment unit takes meter data from the apartmentsheat meter and when the customer has used all their credit, the valvewill shut, preventing the customer from getting into arrears.
The customer can initiate emergency credit, which ensures they do notrun out of heat whilst topping up their card. The card is topped up at alocal shop point. The top up is added to the credit on the system andany emergency credit is automatically deducted. Once the card istopped up, the valve will reopen. Changes in tariff are updatedautomatically when a customer tops up their card. The system includesa number of anti-tamper devices.
Customer display
Mr A B S AMpleSAMple StreetSAMple t ownAB1 2CD
Block H
Moving Home? Call us on 0845 270 7008 up to 7 days before you move with your account number, meter reading and new address.
66761 421
Scottish power energy r etail l td. r egistered o !ce: 1 Atlantic Quay Glasgow G2 8S p.r egistered in Scotland n o 190287. VA t n o GB 659 3720 08.
Date: 07/07/09
package: Standard*
Before you contact us
Please have your meter readings ready before telephoning our customer services centre.
t el n o: 0845 7 292 292
w e may record calls for security and training purposes. w e are open Monday to Friday 8am - 7pm, Saturday 9am - 1pm.
w eb Site: www.scottishpower.co.uk
email: [email protected]
Your electricity number is:
S 01 801 00310 1304 6870 062
Any additional supply numbers are shown overleaf.
Account Number: 1234 5678 100For period: 9/03/09 to 01/07/09
Your electricity charges £153.67
Your energy charges £137.24
Your water charges -£10.62
VAT £13.87
Your total now due is £291.29
please see the reverse of this page for a full breakdown of your charges.
This amount is now due for payment.
Thankyou for being a ScottishPower customer.
t his is not a tax invoice.
Pay now and save!
You could receive a discount of up to £37.50 on your next gas and electricity bill if you pay within 10 days of the date above. Thats a saving of £150 a year for paying your bill on time!
pay your bill quickly and easily at www.scottishpower.co.uk or by calling our self-service Debit Card payment line on 0845 270 0162 with your account number, and card details. Any prompt payer discount will appear on the next bill that you receive.
r eference (Account n umber)
1234 5678 100
r BS Collection Account
12-34-56
Credit Account number
123 4560
Amount due n o fee payable at po counter
£291.29Cheque acceptable at po counter
CASH
CHeQU eS
£
158 208
24
Cashier’s stamp and initials
Signature
Date
Mr A B S AMpleSAMple StreetSAMple t ownAB1 2CD
Please do not write or mark below this line or fold this counterfoil
SAIC
Ltd
013
55 8
4500
Bank Giro Credit
Partner in Technology
The Pay-As-You-Go heating and hot water system is a partnership withInsite Energy. It is not available as hardware only. Insite Energy offers arange of metering and billing services, including Pay-As-You-Go andcredit based billing as well as heating maintenance. Our credit billingpayment options include direct debit, internet payments, telephonepayments, as well as cash payments through the Post Office andPayzone networks. Our services are supported by our 24/7 UK callcentre with multilingual capability.
www.insite-energy.co.uk
Prepayment unit
35
n ENERGY METERS
Flow rate range (qp m3/h) 0.6 - 2.5
Nominal diameter (mm) 15 - 20
Delta t 0 - 90 oC
EEC Approval EN1434 - MID
Flow rate range (qp m3/h) 0.6 - 6
Nominal diameter (mm) 15 - 32
Operating pressure (PN) 16/25 bar
Temperature range (oC) 5 - 130
Sonometer™ 1100 features:• Ultrasonic flow sensor
• Calculator for measuring flow rate,temperature and energy consumption
• Integral high power radio output (if required)
• Combined outputs - MBus and pulse orradio and MBus etc
• Outputs available Mbus, pulse, RS232,RS485, Analogue (4-20mA)
• Battery lifetime – 11 or 16 years, 230Vmains option.
• RHI compliant
The Sonometer™ 1100 is an ultrasoniccompact heat meter especiallydesigned for heating, cooling orcombined heating/cooling applicationin local and district heating systems.The meter is fully MID approved andhas programmable internal datastorage intervals.
microCLIMA thermal energymeter features:
• Single jet or coaxial NON MAGNETICmechanical meter, PN16 rated
• Not magnetic but inductive transmission.Suitable for all kinds of water.
• MID Certified (EN1434)
• High accuracy electronic display with a 10 year battery life
• VS M-Bus output interface (it can powersupply the entire meter); available alsowith 2 PULSE IN.
The microCLIMA compact thermalenergy meter is designed forheating or heating and coolingapplications. The unit conforms tothe latest MID standard, is batterypowered (10 year life) and has anMBus output suitable for remotedata reading and storage.
36
n DATALOGGERS & ACCESSORIES
AMBUS
• Fully digital MBus masters (dataloggers) for small, medium or large projects.
• 25, 60, 120 or 250 M-Bus devices connectable to one Izar Center
• Automatic transmission of meter data via internet connection using integratedLAN interface or external analog/GSM/GPRS modem
• Automatic meter identification by searching the M-Bus network
• Fast and standardized up-to-date communication interfaces
• (Remote) reading and configuration via USB, RS232/modem or LAN interface
• Alarm functionality on consumption and on instantaneous values withnotification (email, SMS)
• Compact housing with rail-mounting possibility
• M-Bus master and level converter in one device. IZAR CENTER (without memory)can also be used as M-Bus repeater (amplifier)
• Cascadable to connect more devices or to build up larger M-Bus networks
• Also available as pre-configured system with or without modem in IP 65 or IP 66 installation housing
Izar Center 25, 60, 120 & 250
AMBUS is an internet compatible ultra versatile datalogger and MBusmanagement centre. It complies with the MBus standard EN1434-3. It is capableof handling 125 or 250 MBus meters (slaves) and is suitable for both commercialand residential installations.
The unit has a large and easy to read touch-screen and a user friendly intuitiveinterface. The unit can monitor and manage the MBus network allowing both instant and automatic reading of networked meters, data storage and communication.
It is extremely versatile and offers a variety of communication options. Meter data isautomatically stored on an integral SD card that can be removed and simply insertedinto a PC or laptop and the data transferred into Microsoft Excel. Unauthorisedaccess to the card is restricted via the internal padlock.
Frequent or remote readings can be carried out through the integral LAN,analogue modem or GSM connections (GSM is optional). An integral web server is also included for access via the internet.
The units compatibility with Microsoft Excel eliminates the need for expensiveoperating software.
A robust housing ensures protection of the unit and enables wall mounting.
37
nWIRELESS METER READING
Hydro radio software: Allows meters of virtually all types, electricity, energy, gas,oil, water etc. Modern client-server architecture, displays an easy to read graphicaltable view of data. Allows for manually read meters values to be inputted as wellas recording meter usage automatically from the docked hand held PC.
Powerful integrated Oracle database can store customer details if required.Monthly/yearly consumption analysis, including configurable alarms. Import,export and backup database functionality. Allows for configuration of the hand held PC.
Hydro Radio Software
Radio to MBus converter - 868. The 868is used for stationary reading of Hydro-radio energy meters, the unit converts an 868 MHz wireless transmission to a twowire direct hard wired MBus connection to a data-logger i.e. 25M and Izar centre.
Internal memory for buffering up to 1000 radio consumption meters.
Internal antenna and LED indicators.
Up to 400m outdoor range and 30m indoor range, 2400 and 9600 baudconnection speed. IP44 rated enclosure.
Landline connection kits (Analogue and
broadband) and GPRS connection kits are
also available, please contact the office
for detail and prices.
Radio to MBus Converter
n COMMUNICATION OPTIONS
38
nWATER METERS
SizeQN TRP-Sealed TRP-Sealed TBR-Wet TBR-Wet Couplings Cartonm3/h Cold 30ºC Hot 90ºC Cold 30ºC Hot 90ºC
1/2” 1.5 See List See List See List See List See List 18
3/4” 2.5 See List See List See List See List See List 18
1” 3.5 See List See List See List See List See List 6
1 1/4” 5.0 See List See List See List See List See List 6
PULSE EMITTER: CD SD Meters can be supplied with standard pulse emitter (1pulse/10L).
The meter can be supplied also pre-equipped for pulse emitter.
CD SD TOP meters are CEE certified B class.
PULSE EMITTER: not available
CD SD Top meters are CEE certified B class.
CD ONE Single Jet Water MeterSEALED REGISTER (TRP) OR WET DIAL (TBR)
SizeQN
Couplings Cartonm3/h
Cold 30ºC Hot 90ºC
1/2” 1.5 See List See List See List 18
3/4” 2.5 See List See List See List 18
CD SD Super Dry Single Jet Water MeterMagnetic Transmission
SizeQN
Couplings Cartonm3/h
Cold 30ºC Hot 90ºC
1/2” 1.5 See List See List See List 20
3/4” 2.5 See List See List See List 20
CD SD Top Super Dry Single Jet Water MeterMagnetic Transmission. Frontal Counter for Easy Reading
PULSE EMITTER: MVM can be supplied with standard or inductive bi-directional pulse emitter
MVM is proposed certified up to R315 (for 1/2 “) and up to 200 for the other sizes. Other ration
on request.
SizeQN
Couplings Cartonm3/h
Cold 50ºC
1/2” 2.5 See List See List
3/4” 4.0 See List See List
1” 6.3 See List See List
MVM Positive Displacement MeterMagnetic Transmission
NEW DIGITAL EASY-READ
PULSE EMITTER: CD ONE TRP Meters can be supplied with standard or static bi-directional pulse emitter.
CD ONE TRP is MID certified R160 (up to 1” - Max water temperature: 50C)
CD ONE TRP (hot water) and CD ONE TBR (cold – hot water) are CEE certified B class (up to 1” size)
NEW
39
nWATER METERS
SizeQN TRP-Sealed TRP-Sealed Couplingsm3/hr Cold 30ºC Hot 90ºC
1/2” 1.5 See List See List See List
3/4” 2.5 See List See List See List
1” 3.5 See List See List See List
1 1/4” 5 See List See List See List
1 1/2” 10 See List See List See List
2” 15 See List See List See List
2”Flanged 15 See List See List See List
PULSE EMITTER: DS TRP Meters can be supplied with standard or static bi-directional pulse emitter.
DS TRP (hot water) is MID certified R160 (up to 1” - Max water temperature: 50C)
DS Multi Jet Water MeterSealed Register (TRP)
Size QN Hot 120ºC QNmm m3/hr
Cold 30ºC Hot 90ºC(Pulsed Output) m3/hr
50 25 See List See List See List 15
65 40 See List See List See List 25
80 100 See List See List See List 32
100 125 See List See List See List 60
125 125 See List See List See List 100
150 225 See List See List See List 150
200 325 See List See List See List 250
250-500 AVAILABLE TO ORDER
PULSE EMITTER: WMAPMeters are pre-equipped with standard and opto output.WAP METERS are CEE cetified class B (cold water)WMAP METERS 120C are PTB certified
Temperature sensors, pressuresensors and sensor pockets
are also available
WMAP Woltmann MeterAxial helix Woltmann meter with interchangeable mechanism
40
n NOTES
41
n NOTES
42
n NOTES
Helping Building Services Engineers Apply Low Carbon Technologies
SAV Systems’ technical team can help specifiers to successfully integrate modules into their projects. Specially prepared design guides are also available.
SAV Systems modules are delivered pre-packaged and pre-tested to integrate easily into modern, fast-track construction programmes.
Heat recovery ventilation systems (HRVS)
LoadTracker combined heat and power (CHP)
(AM&T) Automatic Monitoring and Targeting
FlatStation HIUs & Energy meters
HVAC Commissioning Modules
Manifolds, flexible pipe and actuators
Isolation, balancing valves and water meters
UK CUSTOMER SUPPORT CENTRE SAV Systems, Scandia House, Boundary Road, Woking, Surrey GU21 5BX Telephone: +44 (0)1483 771910 EMAIL: [email protected]