Flash Back Arrestors& Safety Devices
www.ftipv.com
RF53N, -DN, -NU, -U, -NSK – BRASS FBA
CONTROLLINGPRESSURE & VACUUM
Pro
duc
t In
form
atio
nTe
chic
al D
ata
C5
sub
ject
to
cha
nge
SAFETY DEVICES
Ø 24 mm(0.95 inch)
ca. 8
2 m
m(3
.2 in
ch)
RF53N
Ø 24 mm(0.95 inch)
ca. 1
01 m
m(4
.0 in
ch)
RF53DN
ca. 1
10 m
m(4
.3 in
ch)
RF53NSK
Ø 24 mm(0.95 inch)
ca. 8
2 m
m(3
.2 in
ch)
RF53NU
Ø 24 mm(0.95 inch)
ca. 8
2 m
m(3
.2 in
ch)
RF53U
The best Flashback Arrestors in the world• a large surface area flame arrestor FA of stainless steel
construction extinguishes any dangerous flashback entering the device in any direction
• a temperature sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperatureof the arrestors reaches a dangerous level
• a spring loaded non-return valve NV prevents slow or sudden reverse gas flow forming explosive mixtures in thegas supply
• a filter at the gas inlet protects the arrestor against dirtcontamination, extending the service life
• a pressure relief valve vents excessive pressure and sootto the atmosphere protecting the hose from bursting andthe flame arrestor from clogging up thus maintaining theflow rate (only RF53DN)
Operation / Usage• RF Flashback Arrestors are used to protect gas cylinders
and pipeline outlet points (hoses and any equipment)against dangerous reverse gas flow and flashbacks.
• for pipeline outlets and single cylinders: Models RF53N, RF53DNand RF53NSK
• for torches of burners with high flow: Model RF53NU
• for cutting machines with high flow: Model RF53U
• WITT Flashback Arrestors may be mounted in any position /orientation
• only one piece of equipment may be connected to a singleFlashback Arrestor
• the maximum ambient / working temperature is 70 °C
Maintenance• annual testing of the non-return valve, body leak tightness
and flow capacity is recommended
• WITT is happy to supply special test equipment
• Flashback Arrestors are only to be serviced by the manu-facturer. The dirt filter may be replaced by competent staff
ApprovalsCompany certified according to ISO 9001:2000 and ISO 14001
WITT RF Flashback Arrestors for reliable protection against dangerous reverse gas flow and flashbacks according to EN 730 / ISO 5175-1 Certified and under surveillance
Every Arrestor 100% tested.
Models
Safety devices RF53N RF53DN RF53NSK RF53NU RF53U
Flame arrestor FA X X X X X
Non-return valve NV X X X X X
Temperature sensitive cut-off valve TV
X X X X
191191842062191]g[ thgieW
Approval DVGW NG-4390BL0422
40/300/ABZ/MABMAB lavorppA
RC – sgnir-O ;RBN – laes evlaV ;leets sselniatS – rotserra emalF ;ssarB – gnisuoHlairetaM
Ø 24 mm(0.95 inch)
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
RF53N, -DN, -NU, -U, -NSK – BRASS FBA
CONTROLLINGPRESSURE & VACUUM
Tech
nica
l Dat
a
SAFETY DEVICES
RF53NSK
Conversion factors:Acetylene x 1,04Butane x 0,68Natural gas x 1,25Methane x 1,33Propane x 0,80Oxygen x 0,95Town gas x 1,54Hydrogen x 3,75
Conversion factors:Acetylene x 1,04Butane x 0,68Natural gas x 1,25Methane x 1,33Propane x 0,80Oxygen x 0,95Town gas x 1,54Hydrogen x 3,75
Flow diagram for air (20 °C – 68 °F)
Inlet pressure: Pv (bar) Opening pressure: 30 mbar
Sta
ndar
d v
olim
e flo
w [N
m3 /
h](1
013
mb
ar –
14.
7 p
si, 0
°C
– 3
2 °F
)
C5su
bjec
t to
chan
ge
RF53NRF53NURF53URF53DN Flow 10% less
Flow diagram for air (20 °C – 68 °F)
Inlet pressure: Pv (bar) Opening pressure: 30 mbar
Sta
ndar
d v
olim
e flo
w [N
m3 /
h](1
013
mb
ar –
14.
7 p
si, 0
°C
– 3
2 °F
)
Models
Safety devices RF53N RF53DN RF53NSK RF53NU RF53U
Gases max. working pressure [bar]
Acetylene (A) 1.5 1.5 1.5 1.5
Town gas (C) 5.0 5.0 5.0 5.0 5.0
Natural gas (M) 5.0 5.0 5.0 5.0 5.0
0.50.50.50.30.5)P( GPL
Hydrogen (H) 3.0 5.0 3.0 3.0
Connections Order-No.
G 3/8 LH 145.012 145.041 145SK.002 145.034 145.003
530.541340.541610.541HL 2/1 G
G 1/4 LH 145.009
Models
Safety dev ices RF53N RF53 DN RF53NSK RF53NU RF53U
Gases max. working pressure [bar]
Oxygen (O) 30.0 10.0 20.00 30.0 30.0
Compressed air (D) 30.0 10.0 20.00 30.0 30.0
Connections Order-No.
G 1/4 RH 145.021 145.048 145SK.008* 145.036 145.004
G 3/8 RH 145.022 145.049 145SK.001* 145.037 145.005
600.541830.541050.541320.541HR 2/1 G
*RF53NSK with coupling body according to EN 561 – for coupling probes SK100
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
RF85-10, RF85-30 – BRASS FBA
CONTROLLINGPRESSURE & VACUUM
Pro
duc
t in
fora
mti
on
Tech
nica
l dat
a
H4
sub
ject
to
cha
nge
FLASHBACK ARRESTORS RF 53 N / 85-10 / 85-30
Ø 24 mm
ca. 8
2 m
m
Ø 84 mm
ca. 1
88 m
m
TestsEvery WITT Arrestor is tested individually for body leaks, non-return valvefunktion and is subjected to flashback testing at the maximum rated operating pressure in accordance with ISO standards or those of thecountry of sale.
MaintenanceNo maintenance is required. Nevertheless it is recommended that at annual intervals the units are tested with clean dry air or nitrogen for body leakage and against reverse flow. Test specifications and test equipment available on request.
InstallationThe WITT Automatic Flashback Arrestor may be installed at regulator orpipeline outlets. For pipeline use a shut-off valve should be fitted immediately upstream of the arrestor. If there is a danger from water vapour being carried with the gas, then a seperator should be installedupstream. Not more than one process unit may be connected to oneflashback arrestor. It may be mounted horizontally, vertically or any other position. The maximum working temperature is 70° C.
RepairsDetective units as well as units with temperature activated cut-off valve closed should only be serviced by the manufacture or his authorised local representative as it requires full testing including flashback testing after reassembly. The change of the dirt filter is notpart of this requirement and can easily be carried out.
Ø 34 mm
ca. 1
06 m
m
Description:
The WITT Automatic Flashback Arrestors RF 53 N,85-10 and 85-30 incorporate:
• Large surface mesh filter to remove dirt particles from the gas to improve service life ofthe arrestor.
• Spring loaded non-return valve to prevent slowor sudden backfeeding. It is protected fromflashbacks by the downstream arrestor element.
• Large surface area flame arrestor of sintered stainless steel to extinguish any flashback entering the device in any direction. The cylindrical shape gives high flow capacity.
• Temperature activated valve to cut-off the gassupply before the internal temperature reaches a dangerous level. The sealing element is shrouded from flashbacks and the valve closesin the same direction as the gas flow ensuringthat it cannot be re-opened by the gas inletpressure.
WITT Automatic Flashback Arrestors RF 53 N, 85-10 and 85-30 conform to EN 730-1, ISO 5175and other national standards.
RF 53 N
85-10
85-30
Fuel weight housing- seal- RF 53 N 85-10 85-30max. work press Connections approval [g] material material Part No. Part No. Part No.[bar]
5840 MAB5,1 enelytecANatural Gas 5,0
G 3/8 LHNG-4390BL0422 191
145.012 143.002LPGG 1/2 LH
(RF 53 N) (RF 53 N)145.016 143.008RF 53 N RF 53 N, 85-10 5,0
900.541HL 4/1 G85-30 3,5G 3/4 LH 147.00185-10 HydrogenG 1 LH
BAM 0385 434 Brass NBR / CR147.003RF 53 N 3,0 NG-4390BL0421 (85-10)
85-30 )01-58(0,5 01-5885-30 4,0
310.341120.541HR 4/1 GG 3/8 RH
4.580
145.022 143.016Air / OxygenG 1/2 RH
BAM 0890 (85-30)
145.023 143.019G 3/4 RH
NG-4390AS0749
147.00530,0G 1 RH
(85-30)
147.006
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
RF85-10, RF85-30 – BRASS FBA
CONTROLLINGPRESSURE & VACUUM
Tech
nica
l dat
a
FLASHBACK ARRESTORS RF 53 N / 85-10 / 85-30
RF 53 N
85-10
Convesion factors:Acetylene x 1,04Butane x 0,68Natural Gas x 1,25Methane x 1,33Propane x 0,80Oxygen x 0,95Town Gas x 1,54Hydrogen x 3,75
85-30
Pressure drop diagram for Air (20 °C)
Inlet pressure: Pv [bar]/Opening pressure 20 mbar
No
rmal
vo
lum
e flo
w [N
m3 /
h](1
013
mb
ar -
14.
7 p
si, 0
°C
- 3
2°F
)N
orm
al v
olu
me
flow
[Nm
3 /h]
(101
3 m
bar
- 1
4.7
psi
, 0°
C -
32°
F)
No
rmal
vo
lum
e flo
w [N
m3 /
h](1
013
mb
ar -
14.
7 p
si, 0
°C
- 3
2°F
)
H4
sub
ject
to
cha
nge
Inlet pressure: Pv [bar]/Opening pressure 20 mbar
Inlet pressure: Pv [bar]/Opening pressure 20 mbar
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
SUPER 55, SUPER 85 – RESETTABLE FBA
CONTROLLINGPRESSURE & VACUUM
Pro
duc
t In
form
atio
n
SAFETY DEVICES
D6
sub
ject
to
cha
nge
Benefits
• extinguish dangerous flashbacks with sintered stainless steel elements FA
• immediately cut off the gas supply, and therefore prevent dangerous further work after any flashback or gas backflow via pressure sensitive cut-off valve PV
• extinguish sustained backfire – via temperature sensitive cut-off valve TV
• avoid the formation of explosive mixtures in the gassupply – via non-return valves NV
• indicate flashbacks and gas backflow optically – via red alarm mark
• allow simple resumption of work after the cause ofhazard has been removed – via resetting the sleeve
• offer long service life due to protection against dirt – via filter at gas inlet
Operation / Usage
• the Flashback Arrestors are used against gas backflow and flashback at pipeline outlets and singlecylinder equipment.Super 85 for high flow
• the Flashback Arrestors can be installed independentof the orientation but according to gas flow
• each blowpipe should have its own Flashback Arrestor
• maximum ambient / working temperature is 70 °C / 158 °F
Maintenance
• annual testing of the non-return valve, leak tightnessand flow capacity is recommended
• WITT is happy to supply testing equipment
• Flashback Arrestors are only be serviced by the manufacturer. The dirt filter may be replaced by competent staff
Approvals
Company certified according to ISO 9001:2000 and ISO 14001
From the product range „Super“, one of the best flashback arrestors in the world. For reliable protection against dangerous gas backflow and flashback according to EN 730 / ISO 5175-1. Certified and under surveillance
Every Arrestor 100% tested.
58 REPUS55 REPUS
red alarmmark
STOPOPERATE
Ø 27.5 mm(1.08 inch)
app
rox.
119
mm
(4.6
8 in
ch)
red alarmmark
STOPOPERATE
Ø 33.5 mm(1.32 inch)
app
rox.
150
mm
(5.9
1 in
ch)
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
SUPER 55, SUPER 85 – RESETTABLE FBA
CONTROLLINGPRESSURE & VACUUM
Tech
nica
l Dat
a
D6
subj
ect t
o ch
ange
SAFETY DEVICES
SUPER 55
SUPER 85
Conversion factors:Acetylene x 1.04Butane x 0.68Natural Gas x 1.25Methane x 1.33Propane x 0.80Oxygen x 0.95Town gas x 1.54Hydrogen x 3.75
Conversion factors:Acetylene x 1.04Butane x 0.68Natural Gas x 1.25Methane x 1.33Propane x 0.80Oxygen x 0.95Town gas x 1.54Hydrogen x 3.75
0.05
0 0
0.1 0.2 0.3 0.4 0.6 1.0 1.5 2 3 4 6 10 15 20 25 30
P=Pv
P=0.3 bar
P=0.6 bar
P=Pv
P=0.6 bar
P=0.3 bar1
2
3
4
5
6
7
8
9
10
10
40
50
60
70
80
90
100
110
120
130
150
Flow diagram for air (20 °C / 68 °F)
Flow diagram for air (20 °C / 68 °F)
0.05
0 0
0.1 0.2 0.3 0.4 0.6 1.0 1.5 2 3 4 6 10 15 20 25 30
P=Pv
P=0.3 bar
P=0.6 bar
P=Pv
P=0.6 bar
P=0.3 bar20
40
60
80
100
120
140
160
180
200
220
240
260
2
4
6
8
10
12
14
16
18
20
Inlet pressure: Pv [bar] Opening pressure: 30 mbar
Sta
ndar
d v
olu
me
flow
[Nm
3 /h]
(101
3 m
bar
/ 1
4.7
psi
, 0 °
C /
32
°F)
Sta
ndar
d v
olu
me
flow
[Nm
3 /h]
(101
3 m
bar
/ 1
4.7
psi
, 0 °
C /
32
°F)
Inlet pressure: Pv [bar] Opening pressure: 30 mbar
Super 55
Super 85
Gas typemax. working pressure
[bar]
Acetylene (A) 1.5
Hydrogen (H) 3.0
LPG (P)
Town Gas (C) 5.0
Natural Gas, Methane (M)
Oxygen (O)
Non-flammable gases (D) 30.0
Acetylene (A) 1.5Hydrogen (H) 4.0Propane (P)Town Gas (C) Natural Gas, Methane (M) 5.0Ethylene (E)Oxygen (O)Non-flammable gases (D) 30.0
Approval
BAM/ZBA/003/04
BAM/ZBA/003/04
Housingmaterial
Brass
Brass
Sealmaterial
Elastomer
Elastomer
ConnectionEN 560[inch]
G 3/8 LH
G 1/4 RH
G 3/8 RH
G 3/8 LH
G 1/4 RH
G 3/8 RH
146.001
146.003
146.002
148.002
148.013
148.016
Order-No.
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
RF53N-ES, F53N-ES – STAINLESS STEEL FBA
CONTROLLINGPRESSURE & VACUUM
Pro
duc
t In
form
atio
n /
Tech
nica
l Dat
a
L7su
bje
ct t
o c
hang
e
SAFETY DEVICES
approx. 68 mm(2.7 inch)
Ø 2
5 m
m(1
inch
)
F53N-ES / F53N/H-ESRF53N-ES / RF53N/H-ES
The best Flashback Arrestors in the world
• a large surface area flame arrestor FA of stainless steelconstruction extinguishes any dangerous flashback entering the device in any direction
• a temperature sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestors reaches a dangerous level
• a spring loaded non-return valve NV prevents slow or sudden reverse gas flow forming explosive mixtures in thegas supply
• a filter at the gas inlet protects the arrestor against dirt contamination, extending the service life (RF53N-ES)
Operation / Usage• Flashback Arrestors are used to protect gas cylinders and
pipeline outlet points (hoses and any equipment) againstdangerous reverse gas flow (RF53N-ES) and flashbacks
• without non-return valve (F53N-ES) for lower working pressures i.e. before and after analysers
• ideal for use with corrosive gases in the chemical industry,process technology or in the laboratory area
• WITT Flashback Arrestors may be mounted in any position / orientation
• the maximum ambient / working temperature is 70 °C / 158 °F
Maintenance• annual testing of the non-return valve, body leak tightness
and flow capacity is recommended
• WITT is happy to supply special test equipment
• Flashback Arrestors are only to be serviced by the manu-facturer. The dirt filter may be replaced by competent staff
Approvals
Company certified according to ISO 9001:2000 and ISO 14001
WITT Flashback Arrestors for reliable protection against dangerous reverse gas flow and flashbacks according to EN 730 / ISO 5175-1 Certified and under surveillance
Every Arrestor 100% tested.
Other connections available on request
Safety devices F53N F53N/H
X
–
X
181
BAM/ZBA/003/04
Housing – Stainless steel;Flame arrestor – Stainless steel;
Seal – Elastomer
max. working pressure [bar]
–
5.0
5.0
5.0
3.0
–
145.059
–
max. working pressure [bar]
9.0
145.106
–
Order-No.
–
–
12.0
8.0
9.0
1.5
5.0
5.0
5.0
3.0
–
145.001
145.031
30.0
30.0
145.116
145.024
–
–
–
–
–
–
12.0
8.0
9.0
9.0
145.107
145.121
RF53N RF53N/H
X
X
X
195
Model …-ES
Flame arrestor FA
Non-return valve NV
Temperature sensitvecut-off valve TV
Weight [g]
Approval BAM
Material
Gases
Acetylene (A)
Town gas (C)
Natural gas (M)
LPG (P)
Hydrogen (H)
Ethylene (E)
Connections
1/4” NPT F
3/8” NPT F
Gases
Oxygen (O)
Compressed air (D)
Connections
1/4” NPT F
3/8” NPT F
Order-No.
30.0
30.0
145.157
–
–
–
–
–
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
RF53N-ES, F53N-ES – STAINLESS STEEL FBA
CONTROLLINGPRESSURE & VACUUM
Tech
nica
l Dat
a
SAFETY DEVICES
RF53N/H-ES145.107145.121
Conversion factors:Acetylene x 1.04Butane x 0.68Natural gas x 1.25Methane x 1.33Propane x 0.80Oxygen x 0.95Town gas x 1.54Hydrogen x 3.75
Conversion factors:Acetylene x 1.04Butane x 0.68Natural gas x 1.25Methane x 1.33Propane x 0.80Oxygen x 0.95Town gas x 1.54Hydrogen x 3.75
Conversion factors:Acetylene x 1.04Butane x 0.68Natural gas x 1.25Methane x 1.33Propane x 0.80Oxygen x 0.95Town gas x 1.54Hydrogen x 3.75
L7su
bje
ct t
o c
hang
e
RF53N-ES145.001145.031145.116145.024
Flow diagram for air (20 °C / 68 °F)
Flow diagram for air (20 °C / 68 °F)
0.05
0
0.1 0.2 0.3 0.4 0.6 1.0
1
2
3
4
5
6
7
8
9 P=Pv
P=0.3 bar
P=0.6 bar
Inlet pressure: Pv [bar] Opening pressure: 30 mbar
Inlet pressure: Pv [bar]
Sta
ndar
d v
olu
me
flow
[Nm
3 /h]
(101
3 m
bar
/ 1
4.7
psi
, 0 °
C /
32
°F)
Inlet pressure: Pv [bar] Opening pressure: 30 mbar
Sta
ndar
d v
olu
me
flow
[Nm
3 /h]
(101
3 m
bar
/ 1
4.7
psi
, 0 °
C /
32
°F)
Sta
ndar
d v
olu
me
flow
[Nm
3 /h]
(101
3 m
bar
/ 1
4.7
psi
, 0 °
C /
32
°F)
Flow diagram for air (20 °C / 68 °F)
F53N-ES145.059145.157
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
RF85-10N-ES, F85-10N-ES – STAINLESS STEEL FBA
CONTROLLINGPRESSURE & VACUUM
Pro
duc
t In
form
atio
n /
Tech
nica
l Dat
a
L7su
bje
ct t
o c
hang
e
SAFETY DEVICES
The best Flashback Arrestors in the world• a large surface area flame arrestor FA of stainless steel
construction extinguishes any dangerous flashback entering the device in any direction
• a temperature sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestors reaches a dangerous level
• a spring loaded non-return valve NV prevents slow or sudden reverse gas flow forming explosive mixtures in thegas supply
• a filter at the gas inlet protects the arrestor against dirt contamination, extending the service life (only RF85-10N-ES)
Operation / Usage• Flashback Arrestors are used to protect gas cylinders
and pipeline outlet points (hoses and any equipment) with high flow against dangerous reverse gas flow (RF85-10N-ES) and flashbacks
• without non-return valve (F85-10N-ES) for lower workingpressures with low pressure drop i.e. before and after analysers
• ideal for use with corrosive gases in the chemical industry,process technology or in the laboratory area
• WITT Flashback Arrestors may be mounted in any position / orientation
• the maximum ambient / working temperature is 70 °C / 158 °F
Maintenance• annual testing of the non-return valve, body leak
tight-ness and flow capacity is recommended
• WITT is happy to supply special test equipment
• Flashback Arrestors are only to be serviced by the manufacturer. The dirt filter may be replaced by competent staff
ApprovalsCompany certified according to ISO 9001:2000 and ISO 14001
WITT Flashback Arrestors for reliable protection against dangerous reverse gas flow and flashbacks according to EN 730 / ISO 5175-1 Certified and under surveillance
Every Arrestor 100% tested.
Other connections available on request
approx. 97 mm(3.82 inch)
Ø 3
4 m
m(1
.34
inch
)
approx. 106 mm(4.17 inch)
Ø 3
4 m
m(1
.34
inch
)
Safety devices F85-10N F85-10N/H
X
–
X
385
BAM/ZBA/003/04
Housing – Stainless steel;Flame arrestor – Stainless steel;
Seal – Elastomer
max. working pressure [bar]
–
5.0
5.0
5.0
4.0
5.0
143.028
143.122
–
–
max. working pressure [bar]
9.0
143.100
–
–
–
Order-No.
–
–
10.0
5.0
10.0
1.5
5.0
5.0
5.0
4.0
5.0
143.061
143.069
143.031
143.048
30.0
30.0
143.101
143.119
143.163
143.134
–
–
–
–
–
–
–
–
10.0
5.0
10.0
9.0
143.077
143.087
–
143.076
RF85-10N RF85-10N/H
X
X
X
385
Model …-ES
Flame arrestor FA
Non-return valve NV
Temperature sensitivecut-off valve TV
Weight [g]
Approval BAM
Material
Gases
Acetylene (A)
Town gas (C)
Natural gas (M)
LPG (P)
Hydrogen (H)
Ethylene (E)
Connections
1/4” NPT F
3/8” NPT F
9/16”-18UNF VCR
7/8” -14UNF VCR
Gases
Oxygen (O)
Compressed air (D)
Connections
1/4” NPT F
3/8” NPT F
9/16”-18UNF VCR
7/8” -14UNF VCR
Order-No.
30.0
30.0
143.149
143.198
–
–
–
–
–
–
–
–
F85-10N-ES / F85-10N/H-ESRF85-10N-ES / RF85-10N/H-ES
RF85-10N-ES VCRRF85-10N/H-ES VCR
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
RF85-10N-ES, F85-10N-ES – STAINLESS STEEL FBA
CONTROLLINGPRESSURE & VACUUM
Tech
nica
l Dat
a
SAFETY DEVICES
RF85-10N/H-ES143.076143.077143.087
Conversion factors:Acetylene x 1.04Butane x 0.68Natural gas x 1.25Methane x 1.33Propane x 0.80Oxygen x 0.95Town gas x 1.54Hydrogen x 3.75
Conversion factors:Acetylene x 1.04Butane x 0.68Natural gas x 1.25Methane x 1.33Propane x 0.80Oxygen x 0.95Town gas x 1.54Hydrogen x 3.75
Conversion factors:Acetylene x 1.04Butane x 0.68Natural gas x 1.25Methane x 1.33Propane x 0.80Oxygen x 0.95Town gas x 1.54Hydrogen x 3.75
L7su
bje
ct t
o c
hang
e
RF85-10N-ESRF85-10N-ES VCR143.031143.048143.061143.069143.101143.119143.134143.163
Flow diagram for air (20 °C / 68 °F)
Flow diagram for air (20 °C / 68 °F)
Inlet pressure: Pv [bar] Opening pressure: 30 mbar
Inlet pressure: Pv [bar]
Sta
ndar
d v
olu
me
flow
[Nm
3 /h]
(101
3 m
bar
/ 1
4.7
psi
, 0 °
C /
32
°F)
Inlet pressure: Pv [bar] Opening pressure: 30 mbar
Sta
ndar
d v
olu
me
flow
[Nm
3 /h]
(101
3 m
bar
/ 1
4.7
psi
, 0 °
C /
32
°F)
Sta
ndar
d v
olu
me
flow
[Nm
3 /h]
(101
3 m
bar
/ 1
4.7
psi
, 0 °
C /
32
°F)
Flow diagram for air (20 °C / 68 °F)
F85-10N-ES143.028143.122143.149143.198
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
RF85-30N-ES, RF85-30N/H-ES – STAINLESS STEEL FBA
CONTROLLINGPRESSURE & VACUUM
Pro
du
ct In
form
atio
n /
Tec
hn
ical
Dat
a
K7
sub
ject
to c
hang
e
Other connections available on request
SAFETY DEVICES
WITT Flashback Arrestors for reliable protection against dangerous reverse gas flow and flashbacks according to EN 730 / ISO 5175-1 Certified and under surveillance
Every Arrestor 100% tested.
Benefits
• a large surface area flame arrestor FA of stainless steel construction extinguishes any dangerous flashback entering the device in any direction
• a temperature sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestors reaches a dangerous level
• a spring loaded non-return valve NV prevents slow or sudden reverse gas flow forming explosive mixtures in the gas supply
• a filter at the gas inlet protects the arrestor against dirt contamination, extending the service life
Operation / Usage
• Flashback Arrestors are used to protect gas cylinders and pipeline outlet points (hoses and any equipment) against dangerous reverse gas flow and flashbacks
• ideal for use with corrosive gases in the chemical industry, process technology or in the laboratory area
• for pipeline outlets and single cylinders with high users for example supply units for gas cutting machines
• WITT Flashback Arrestors may be mounted in any position / orientation
• only one piece of equipment may be connected to a single Flashback Arrestor
• the maximum ambient / working temperature is 70 °C / 158 °F
Maintenance
• annual testing of the non-return valve, body leak tightness and flow capacity is recommended
• WITT is happy to supply special test equipment
• Flashback Arrestors are only to be serviced by the manufacturer. The dirt filter may be replaced by competent staff
Approvals
Company certified according to ISO 9001:2000 and ISO 14001CE-marked according to: - PED 97/23/EG
Model Safety devices RF85-30N-ES RF85-30N/H-ES
Flame arrestor FA X X
Non-return valve NV X X
Temperature sensitive cut-off valve TV X X
Weight [g] 4455 4344
Material Housing – Stainless steel;
Flame arrestor – Stainless steel; Seal – Elastomer
Gases max. working pressure [bar]
Acetylene (A) 1.5 –
Town gas (C) 5.0 –
Natural gas (M) 5.0 8.0
LPG (P) 3.5 5.0
Hydrogen (H) 4.0 11.0
Ethylene (E) 4.0 –
Connections Order-No.
3/4“ NPT F 147.027 147.039
1“ NPT F – 147.047
Gases max. working pressure [bar]
Oxygen (O) 30.0 –
Compressed air (D) 30.0 –
Connections Order-No.
3/4“ NPT F 147.028 –
RF85-30N-ESRF85-30N/H-ES
Ø 84 mm
appr
ox. 1
62 m
m
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
RF85-30N-ES, RF85-30N/H-ES – STAINLESS STEEL FBA
CONTROLLINGPRESSURE & VACUUM
K7
sub
ject
to c
hang
e
Tec
hn
ical
Dat
a
SAFETY DEVICES
RF85-30N-ES 147.027147.028
RF85-30N/H-ES 147.039147.047
Flow diagram for air (20 °C / 68 °F)
Sta
ndar
d vo
lum
e flo
w [N
m3 /h
] (1
013
mba
r / 1
4.7
psi,
0 °C
/ 32
°F
)
Flow diagram for air (20 °C / 68 °F)
Inlet pressure: PV [bar] Opening pressure: 10 mbar
0.05
0 0
0.1 0.2 0.3 0.4 0.6 1.0 1.5 2 3 4 6 10
P=Pv
P=0.3 bar
P=0.6 bar
P=0.6 bar
P=0.3 bar
202
4
6
8
10
12
14
16
18
20
406080
100120
140160180200220240260
280300320340360
380400
12
P=Pv
Sta
ndar
d vo
lum
e flo
w [N
m3 /h
] (1
013
mba
r / 1
4.7
psi,
0 °C
/ 32
°F
)
Conversion factors: Acetylene x 1.04 Butane x 0.68 Natural Gas x 1.25 Methane x 1.33 Propane x 0.80 Oxygen x 0.95 Town gas x 1.54 Hydrogen x 3.75
Conversion factors: Acetylene x 1.04 Butane x 0.68 Natural Gas x 1.25 Methane x 1.33 Propane x 0.80 Oxygen x 0.95 Town gas x 1.54 Hydrogen x 3.75
Inlet pressure: PV [bar] Opening pressure: 10 mbar
0.05
0
p=p
p=0.6 bar
p=0.3 bar
p=p
p=0.6 bar
p=0.3 bar
70
50
60
40
30
20
10
200
300
400
600
500
800
700
900
1000
0
100
1100
1200
v
v80
0.1 0.2 0.3 0.6 1.0 1.5 2 3 4 6 8 10 20 3015
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
F100N-ES – FBA FOR HIGH PRESSURE HYDROGEN
CONTROLLINGPRESSURE & VACUUM
Pro
du
ct In
form
atio
n /
Tec
hn
ical
Dat
a
K7
sub
ject
to c
hang
e
Other connections available on request
SAFETY DEVICES
WITT Flashback Arrestors for reliable protection against dangerous flashbacks according to EN 730 / ISO 5175-1, for hydrogen (H2) up to 17 bar. Every Arrestor 100% tested.
Benefits
• a large surface area flame arrestor FA of stainless steel construction extinguishes any dangerous flashback entering the device in any direction
• a temperature sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestors reaches a dangerous level
Operation / Usage
• the Flashback Arrestors are used to protect gas cylinders and pipeline outlet points (hoses and any equipment) against flashbacks at highest working pressures up to 17 bar, at hydrogen in case of flame spraying
• ideal for use with corrosive gases in the chemical industry, or process technology
• WITT Flashback Arrestors may be mounted in any position / orientation
• the maximum ambient / working temperature is 70 °C / 158 °F
Maintenance
• annual testing of the body leak tightness and flow capacity is recommended
• Flashback Arrestors are only to be serviced by the manufacturer
Approvals Company certified according to ISO 9001:2000 and ISO 14001
Model
Safety devices F100-17N-ES
Flame arrestor FA X
Temperature sensitive cut-off valve TV X
Weight [g] 1236
Material Housing – Stainless steel;
Flame arrestor – Stainless steel; Seal – Elastomer
Gases max. working pressure [bar]
Hydrogen (H) 17.0
Connections Order-No.
1/2“ NPT F 210.000012
F100-17N-ES 210.000012
Sta
ndar
d vo
lum
e flo
w [N
m3 /h
] (1
013
mba
r / 1
4.7
psi,
0 °C
/ 32
°F
Inlet pressure: PV [bar]
F100N-ES
Flow diagram for hydrogen (20 °C / 68 °F)
appr
ox. 4
8 m
m
approx. 103 mm
0
0
P=Pv
P=0.3 bar5
1510
20253035404550556065707580859095
100
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
P=0.9 bar
P=1.5 bar
P=3 bar
P=5 bar
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
FN12 & FN40 – FOR ACETYLENE
CONTROLLINGPRESSURE & VACUUM
Pro
duc
t In
form
atio
nTe
chni
cal D
ata
L5su
bje
ct t
o c
hang
e
SAFETY DEVICES
Ø 70 mm(2.75 inch)
ca. 1
60 m
m(6
.30
inch
)
Ø 70 mm(2.75 inch)
ca. 2
00 m
m(7
.87
inch
)
Decomposition Arrestors
WITT Decomposition Arrestors for reliable protection against decomposition of acetylene and flashbacksEvery Arrestor 100% tested. Certified and under surveillance
The best Decomposition Arrestors in the world
• a large surface area flame arrestor FA of stainlesssteel construction:- stops dangerous decomposition of acetylene
independent from flow direction- extinguishes any dangerous flashback entering
the device in any direction• a temperature sensitive cut-off valve TV extin-
guishes sustained flashbacks long before the internal temperature of the arrestor reaches a dangerous level
Operation / Usage
• as a Decomposition Arrestor in low pressure pipe-lines for protection from cylinder equipment andbundles
• as a safety device (FN40) to protect against flash-backs in accordance to EN 730
• as a safety device to protect pipelines in supply systems
• FN40 for double flow capacity• WITT Decomposition Arrestors may be moun-
ted in any position / orientation• the maximum ambient / working temperature
is 70 °C / 158 °F
Maintenance• it is recommended that an annual body leakage
test is performed• Decomposition Arrestors are only to be serviced
by the manufacturer
ApprovalsCompany certified according to ISO 9001:2000and ISO 14001 CE-marked according to:- PED 97/23/EG
ModelMax. working pressure
[barg]Housing-Material
Seal-Material
Weight[g]
Connection[inch]
Order-No.
Acetylene (A) 1.5 bar
Brass Elastomer
3091 G 1.1/2 RH 021.001
300.120HR 2/1.1 G6483rab 5.1)A( enelytecA
600.120HR 2/1.1 G6483rab 0.3)H( negordyH
Natural gas (M) 2.0 barLPG (P) 1.5 bar
3846 G 1.1/2 RH 021.008
FN12BAM/ZBA/003/04
FN40
FN40
FN40
Other connections available on request
FN40FN12
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
FN12 & FN40 – FOR ACETYLENE
CONTROLLINGPRESSURE & VACUUM
Tech
nica
l Dat
a
SAFETY DEVICES
FN12 Flow diagram for air (20 °C / 68 °F)
Inlet pressure: Pv [bar]
Sta
ndar
d v
olu
me
flow
[Nm
3 /h]
(101
3 m
bar
/ 1
4.7
psi
, 0 °
C /
32
°F)
FN40 Flow diagram for air (20 °C / 68 °F)
Inlet pressure: Pv [bar]
Sta
ndar
d v
olu
me
flow
[Nm
3 /h]
(101
3 m
bar
/ 1
4.7
psi
, 0 °
C /
32
°F)
L5su
bje
ct t
o c
hang
e
Flame arrestor FA Melting body fromtemperature sensitivecut-off valve TV
Temperature sensitivecut-off valve
Conversion factors:Acetylene x 1.04Natural Gas x 1.25Methane x 1.33Propane x 0.80Hydrogen x 3.75
Conversion factors:Acetylene x 1.04
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
HDS 17 – FOR ACETYLENE
CONTROLLINGPRESSURE & VACUUM
Pro
duc
t In
form
atio
nTe
chni
cal D
ata
B6
sub
ject
to
chan
ge
SAFETY DEVICES
Ø 50 mm(1.97 inch)
ca. 1
52 m
m(5
.98
inch
)
Automatic Quick Acting Shut-Off Device HDS17
WITT Automatic Quick Acting Shut-Off Devices (slam shut valves) for reliable protection against dangerous decomposition of acetylene in high pressure pipelines in accordance to EN ISO 14114 Every Arrestor 100% tested. Certified and under surveillance
The best Automatic Quick Acting Shut-Off Devicesin the world
• a pressure sensitive piston valve stops explosivedecomposition of acetylene
• immediately cuts off the gas supply in case of decomposition of acetylene
Operation / Usage
• as an Automatic Quick Acting Shut-Off Device according to EN ISO 14114 in high pressure pipelines, which are immediately supplied by more than six cylinders
• WITT Automatic Quick Acting Shut-Off Devicesmay be mounted in any position / orientation
• the maximum ambient / working temperature is 70 °C / 158 °F
Maintenance• it is recommended that an annual body leakage
test is performed
• Automatic Quick Acting Shut-Off Devices are onlyto be serviced by the manufacturer
Approvals
Manufactured in accordance to EN ISO 15615
Company certified according to ISO 9001:2000 and ISO 14001
ModelMax.
working pressure[barg]
Materials Weight [g]
Connection[inch] Order-No.
HDS17BAM/ZBA/003/04 Acetylene (A) 25.0 bar
Aluminium / galvanised steel,
chromed, Elastomer
1797 G 3/4 RH 017.001
Other connections available on request
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
HDS 17 – FOR ACETYLENE
CONTROLLINGPRESSURE & VACUUM
Tech
nica
l Dat
a
SAFETY DEVICES
HDS17 Flow diagram for acetylene (20 °C / 68 °F)
Pressure difference: ΔP [bar]
Stan
dard
vol
ume
flow
[Nm
3/h]
(101
3 m
bar /
14.
7 ps
i, 0
°C /
32 °F
)
B6
sub
ject
to
chan
ge
pressure sensitivepiston valve
f.t.i. ltd t: 01892 669939 f: 01892 669594 e: [email protected] w: www.ftipv.com
f.t.i ltd – head office
unit 13, april court, sybron way, jarvis brook, east sussex. tn6 3dz
t: 01892 669939 f: 01892 669594 e:[email protected] www.ftipv.com