  N:\WP\GENERAL\ABELL\2 014\Memo \Flange Procedures Memo 31071 4.doc MEMORANDUM SCOPUS ENGINEERING LIMITED To: All Surveyors From: Scopus QA/QC Subject: Flange Survey Requirements Date: 31/07/14 Reference: Flange Survey Requirements There have been instances recently where TP flanges have been calculated incorrectly. In some cases this has caused Pipework to be fabricated dimensionally incorrect and subsequent rework required. Upon investigation the surveyed Flanges have had a thickness of 0mm input during Survey calculations causing the 3D Asbuilt position of the Flange to be incorrect. The investigation also revealed that no log file data showing the input Flange thickness of 0mm was  present in the relevant field. Input of the correct Flange thickness, Interrogating flange survey data and log files, being aware that some data may be missing and making corrective action prior to formal issue of results is of  paramount importance and the responsibility of both Surveyor and Su rvey checker. All Scopus surveyors are therefore reminded that all dimensional control surveys, processing, finalising and issuing of formal results must be in accordance with Scopus LRQA ISO 9001 2008 accreditation and in house procedure SCOP-DSC-003. It is of the utmost importance that ALL Survey results are correct at time of issue and any incorrect input of data identified and corrected pre issue. Included is a ty pical example of Flange data input with 0mm thickness which in turn places the surveyed Flange in an incorrect position- correct input of data also included  Note- the Survey Program Code is currently being modified to prevent a thickness of 0mm being entered. However, prior to the issue of the updated Survey Program ALL Surveyors must be aware of the issues noted above and ensure input of 0mm or incorrect input of Flange thickness are identified and corrected prior to the formal issue of Survey results.

Flange Thickness

Embed Size (px)

Citation preview

Page 1: Flange Thickness

8/11/2019 Flange Thickness

http://slidepdf.com/reader/full/flange-thickness 1/3

 

MEMORANDUM SCOPUS ENGINEERING LIMITED

To: All Surveyors From: Scopus QA/QC

Subject: Flange Survey Requirements Date: 31/07/14

Reference: Flange Survey Requirements

There have been instances recently where TP flanges have been calculated incorrectly. In some

cases this has caused Pipework to be fabricated dimensionally incorrect and subsequent rework

required.

Upon investigation the surveyed Flanges have had a thickness of 0mm input during Survey

calculations causing the 3D Asbuilt position of the Flange to be incorrect.

The investigation also revealed that no log file data showing the input Flange thickness of 0mm was

 present in the relevant field.

Input of the correct Flange thickness, Interrogating flange survey data and log files, being aware that

some data may be missing and making corrective action prior to formal issue of results is of

 paramount importance and the responsibility of both Surveyor and Survey checker.

All Scopus surveyors are therefore reminded that all dimensional control surveys, processing,

finalising and issuing of formal results must be in accordance with Scopus LRQA ISO 9001 2008

accreditation and in house procedure SCOP-DSC-003.

It is of the utmost importance that ALL Survey results are correct at time of issue and any incorrect

input of data identified and corrected pre issue.

Included is a typical example of Flange data input with 0mm thickness which in turn places the

surveyed Flange in an incorrect position- correct input of data also included

 Note- the Survey Program Code is currently being modified to prevent a thickness of 0mm being

entered.

However, prior to the issue of the updated Survey Program ALL Surveyors must be aware of the

issues noted above and ensure input of 0mm or incorrect input of Flange thickness are identified and

corrected prior to the formal issue of Survey results.

Page 2: Flange Thickness

8/11/2019 Flange Thickness

http://slidepdf.com/reader/full/flange-thickness 2/3

  GENERAL REQUIREMENTS FOR MIRRORING A SURVEYED FLANGE

0mm 

Thickness 

entered 

When checking survey be aware 

that if  flange data for thickness is 

entered 

as 

0mm 

there 

will 

be 

no 

field 

for 

thickness 

in 

log 

file. 

F01 of 

 surveyed

 flange

 

E. 

406419 

N. 204776 

EL.+24727 

C012 ‐ Direction Survey Point 

Scripted flange in incorrect position. 

When 

flange 

thickness 

is 

entered 

as 

0mm, 

the 

scripted 

position 

of  

mirrored 

flange 

is 

incorrect. 

Flange m01 

C014 ‐ Bolt Survey Points

C013 ‐

Face 3 Survey

 Points

 

Incorrect Thickness Entered

Page 3: Flange Thickness

8/11/2019 Flange Thickness

http://slidepdf.com/reader/full/flange-thickness 3/3

  GENERAL REQUIREMENTS FOR MIRRORING A SURVEYED FLANGE

Correct 

Thickness 

entered 

Flange thickness entered as 

measured by taping on site. 

Scripted flange in correct position. 

Mirroring 

flange 

by 

thickness, 

raised 

face, and 

gasket sum. 

C013 ‐ Face 3 Survey Points 

Flange m01 

C014 ‐ Bolt

 Survey

 Points

F01 of  surveyed flange 

E. 

406454 

N. 

204776 

EL.+24729 

Correct Thickness Entered 

C012  – Direction Survey Point