8
The first look at sagitta resolution vs momentum (F. Cerutti –E. Meoni –S. Rosati - A. Policicchio- S. Ventura) easure of sagitta resolution on barrel and beam momentum for a dat ng conditions: Energy beam 250 GeV, MDT Main Ths -40mV- Trigger 10X10 – BIL Rot ON/OFF- Magnet current 0A/600 A ber: 600681(73Kevt) – 600682(97Kevt) – 600722(30Kevt)- 50Kevt)- 600724(32Kevt)- 600725(71 Kevt) icular: MBPL magnet at 600A BIL rotation OFF (P and sagitta measur.) MBPL magnet at 0A BIL rotation OFF (Alignment BIL rot. vs. Barr

First measure of sagitta resolution on barrel and beam momentum for a data set

  • Upload
    lan

  • View
    25

  • Download
    0

Embed Size (px)

DESCRIPTION

The first look at sagitta resolution vs momentum (F. Cerutti –E. Meoni –S. Rosati - A. Policicchio- S. Ventura). First measure of sagitta resolution on barrel and beam momentum for a data set Operating conditions: Energy beam 250 GeV, MDT Main Ths -40mV- - PowerPoint PPT Presentation

Citation preview

Page 1: First measure of sagitta resolution on barrel and  beam momentum for a data set

The first look at sagitta resolution vs momentum

(F. Cerutti –E. Meoni –S. Rosati - A. Policicchio- S. Ventura)First measure of sagitta resolution on barrel and beam momentum for a data set

Operating conditions: Energy beam 250 GeV, MDT Main Ths -40mV- Trigger 10X10 –

BIL Rot ON/OFF- Magnet current 0A/600 A

Run number: 600681(73Kevt) – 600682(97Kevt) – 600722(30Kevt)-600723(50Kevt)- 600724(32Kevt)- 600725(71 Kevt)

In particular: 600724 MBPL magnet at 600A BIL rotation OFF (P and sagitta measur.)600725 MBPL magnet at 0A BIL rotation OFF (Alignment BIL rot. vs. Barrel )

Page 2: First measure of sagitta resolution on barrel and  beam momentum for a data set

T0 fitsBIL rot ml=1 mezzanine=2BIL2 ml=2 mezzanine=2

BML2 ml=2 mezzanine=2 BOL2 ml=2 mezzanine=3

T0 fits computed grouping TDC spectra of channels inthe same mezzanine

Fermi-Dirac distribution

Applied a cut on ADC counts:accepted hits withADC > 45

Page 3: First measure of sagitta resolution on barrel and  beam momentum for a data set

Residual Distributions

BIL rot ml=1 BOL2 ml=2

mm

mmmmmm

R-T relation produced by Rome3 with calib for the run 600379:BIL Rot ON, ± 10degree, 18 June.(for drift distences smaller than 2mm used a linear r-t relation)

Events reconstructed with athena 8.5.0

Systematic error at level of 50m related to temperatureeffects and t0 effects

mm

mm

BIL2 ml=1 mm

mm

Page 4: First measure of sagitta resolution on barrel and  beam momentum for a data set

Barrel sagitta

mm

BOL

BML

BIL

Selected track segments in the jura-side chambers (most illuminated)

Sigma 68 m

Page 5: First measure of sagitta resolution on barrel and  beam momentum for a data set

Beam Profile on RPC phi-strips

BML2 rdoublr=1 BML2 rdoublr=2

We select the most illuminated phi-strips: at least one hit in this strip for RPC rdoublr=1 (behind the MDT)and one for RPC rdoublr=2 (beyond the MDT) in BML station.

Page 6: First measure of sagitta resolution on barrel and  beam momentum for a data set

P measurement B(600A) B(0A)

Momentum

GeV

)0,()600,()(3.0)(

ABABTmBLGeVP

entbilrotsegmentbarrelsegm

Mean=233 GeVSigma=15 GeV

BL=3.54 Tm

Page 7: First measure of sagitta resolution on barrel and  beam momentum for a data set

Sagitta Distribution (RPC cuts + Pcut)

ooo XxXxp ln0038.01MeV6.13 osm ZZ

ZZZZS tan13

2312..

Multiple scattering contribute to sagitta resolution:

For p=233 GeV (Sms)=29 m

Sigma 63 m

P > 215 GeV

mSSS msmeasi 56)()()( 22

mm

Page 8: First measure of sagitta resolution on barrel and  beam momentum for a data set

Final observation…

Phi-strip position (mm)

Sagi

tta(

m)