FIRE RETARDANT SYSTEMS AND SOLUTIONS

Marketed by :

Page 2: FIRE RETARDANT SYSTEMS AND SOLUTIONS

INTRODUCTION• We at Multi kilfire believe strongly in the adage “PREVENTION IS BETTER

THAN CURE”. Active Fire Systems which include hydrants, sprinklers & smoke detectors, come into play only after the fire breaks out; whereas Passive Systems help in preventing and retarding fires. While Passive systems cannot be considered to be an alternative to Active systems, they definitely rationalize the need for extensive deployment of Active Systems. A marriage between both types of systems is not only physically safer but also more cost effective.

Page 3: FIRE RETARDANT SYSTEMS AND SOLUTIONS

PRODUCTS APPROVED BY:

• Raytheon U.S.A.• Tata Consulting

Engineers• Rolls Royce U.K.• BHEL• MECON

• M. N. Dastur & Co.

• DEISIN• DCL• FICHTNER• EIL

Page 4: FIRE RETARDANT SYSTEMS AND SOLUTIONS

FIRE RETARDANT COATING FOR ELECTRICAL CABLES – KF600

Page 5: FIRE RETARDANT SYSTEMS AND SOLUTIONS

EFFECTIVENESS OF FIRE RETARDANT COATING

Functions by limiting the oxygen drawn from the atmosphere, thereby inhibiting the combustion and heat build-up process in the immediate vicinity of the cable insulation.

The coating converts the bunch of cables into one coated cable and compartmentalizes an uncoated fire zone from the coated non – fire zone.

Dissipates the heat generated by the fire and thereby prevents heat conduction.

Page 6: FIRE RETARDANT SYSTEMS AND SOLUTIONS

TECHNICAL DATA Physical Properties –

Ph – 6 to 8, Odourless, touch dry – 45 mins; hard dry 72 hrs. Flammability as per IEEE – 383 / 10810-Part 53. Fire Survival as per IEC – 331-21 ( One hour) Flexibility, adhesion as per IS – 101 and IS 10810 Part 50. Current Carrying Capacity. (Ampacity and Insulation test) Anti Termite / Anti Rodent. Toxicity as per IEC – 754. (Halogen Content) Limiting Oxygen Index as per ASTM – D 2863-1991 Flame Propagation as per IEC 332-3 Category A Heat Ageing as per IS 5831 Test for Asbestos content. Chemical Resistance Test. Oil immersion test. Water Immersion Test

Page 7: FIRE RETARDANT SYSTEMS AND SOLUTIONS

RECOMMENDED DIMENSIONS & AREAS – CABLE COATING KF 600

Page 8: FIRE RETARDANT SYSTEMS AND SOLUTIONS

SOME PHOTOGRAPHS

Page 9: FIRE RETARDANT SYSTEMS AND SOLUTIONS

COATING ILLUSTRATION

Page 10: FIRE RETARDANT SYSTEMS AND SOLUTIONS

LIVE DEMONSTRATION

Page 11: FIRE RETARDANT SYSTEMS AND SOLUTIONS

FIRE SPREAD TEST KF 600AT UKAI TPS

Page 12: FIRE RETARDANT SYSTEMS AND SOLUTIONS
Page 13: FIRE RETARDANT SYSTEMS AND SOLUTIONS
Page 14: FIRE RETARDANT SYSTEMS AND SOLUTIONS
Page 15: FIRE RETARDANT SYSTEMS AND SOLUTIONS

IEEE – 383 FLAMMABILITY TESTAT ERDA, BARODA

Page 16: FIRE RETARDANT SYSTEMS AND SOLUTIONS

TEST CHAMBER

Page 17: FIRE RETARDANT SYSTEMS AND SOLUTIONS

INSIDE TEST CHAMBER

Page 18: FIRE RETARDANT SYSTEMS AND SOLUTIONS

WRAPPING BURLAP ON COATED CABLE- 2.45 M LONG

Page 19: FIRE RETARDANT SYSTEMS AND SOLUTIONS

BURLAP TIED AT 1 M FROM BOTTOM

Page 20: FIRE RETARDANT SYSTEMS AND SOLUTIONS

BURLAP LIT

Page 21: FIRE RETARDANT SYSTEMS AND SOLUTIONS

SOME

INSTALLATION

PHOTOGRAPHS

Page 22: FIRE RETARDANT SYSTEMS AND SOLUTIONS

CONTROL PANEL - SUZLON

Page 23: FIRE RETARDANT SYSTEMS AND SOLUTIONS

ADITYA BIRLA, ULTRATECH CEMENT, TADAPATRI

Page 24: FIRE RETARDANT SYSTEMS AND SOLUTIONS

GSPCL

Page 25: FIRE RETARDANT SYSTEMS AND SOLUTIONS

JSPL

Page 26: FIRE RETARDANT SYSTEMS AND SOLUTIONS

KF 604 – FIRE STOP BARRIERS.

Page 27: FIRE RETARDANT SYSTEMS AND SOLUTIONS

NOMENCLATURE – DIFFERENT NAMES

• FIRE STOP COMPOUND• FIRE STOP BARRIER• FIRE SEALING SYSTEM• FIRE PENETRATION SEALING SYSTEM• FIRE COMPARTMENTILISATION• FIREPROOF SEALING• FPSS

Page 28: FIRE RETARDANT SYSTEMS AND SOLUTIONS

DESCRIPTION

THESE ARE MORTAR-TYPE FIRE BARRIERS, WITH A THREE HOUR FIRE RATING, WHICH ARE INSTALLED IN OPENINGS (FLOOR / WALL) WHERE CABLES / CABLE TRAYS PASS FROM ONE ROOM TO THE OTHER OR FOR SEALING OPENINGS UNDER ELECTRIC SWITCH GEAR, LIKE HT AND LT CONTROL PANELS. THEY PREVENT FIRE FROM SPREADING FROM ONE ROOM TO THE OTHER.

Page 29: FIRE RETARDANT SYSTEMS AND SOLUTIONS

TECHNICAL DATAThe system has been successfully tested at the only approved CSIR Laboratory for such a product at CBRI, Rourkee. The parameters tested for is highlighted hereunder:

a. Impact Test b. Accelerated Ageing. c. Water Absorption. d. Vibration Test. e. Fire Resistance Evaluation. f. Hose Stream evaluation. g. F – Rating h. T – Rating.

Page 30: FIRE RETARDANT SYSTEMS AND SOLUTIONS

Single Component non – combustible system. Designed for 3 (three) hour fire rating. Segregates / compartmentalizes fire and non – fire zones. Compatible with all types of cable jacketing material. No effect due to vibration, impact and radiation. Mechanically strong and can bear drop loads. Retrofitting very easy without special tools. Conforms to Indian and International standards. No imported components. Indigenously developed. Maintenance free. Asbestos free. Expected life – will last the life of the cable.

Page 31: FIRE RETARDANT SYSTEMS AND SOLUTIONS

FIRE TEST AT CBRI ROURKEE

• Electrical cables are extensively used in all major industries. These are mostly run through underground cable tunnels, trenches, overhead cable trays and ducts. Any fire incidence in the vicinity of these may result in spread of fire along the cable trays as modern production facilities demand long run of power and control cables all over the Plant area.

Page 32: FIRE RETARDANT SYSTEMS AND SOLUTIONS

FIRE TEST AT CBRI ROURKEE

• The fire safety can be enhanced by providing Fire Stop Barriers at different intervals and by sealing the openings.

• The complete cable Barrier should be thoroughly evaluated before its installation for providing compartmentation

Page 33: FIRE RETARDANT SYSTEMS AND SOLUTIONS

FIRE TEST AT CBRI ROURKEE• We sponsored the Project to evaluate the

performance of our cable Fire Barrier KF-604 with respect to furnace heating conditions and other appropriate procedures specified in relevant Standards.

• The Fire Research Laboratory at Rourkee approved by CSIR Laboratory has established standard facilities conforming to various National and International Standards for evaluating Fire Resistance of different type of systems.

Page 34: FIRE RETARDANT SYSTEMS AND SOLUTIONS

TYPE TEST SAMPLE FOR TESTING AT CBRI, ROURKEE

Page 35: FIRE RETARDANT SYSTEMS AND SOLUTIONS

KF-604 BEING READIED FOR FIRE TEST AT C.B.R.I. ROORKEE

Page 36: FIRE RETARDANT SYSTEMS AND SOLUTIONS

ILLUSTRATIONS

Page 37: FIRE RETARDANT SYSTEMS AND SOLUTIONS

WALL AND FLOOR OPENINGS

ILLUSTRATION OF BARRIER INSTALLATION IN

WALL OPENING ILLUSTRATION OF BARRIER INSTALLATION

IN FLOOR OPENING

Page 38: FIRE RETARDANT SYSTEMS AND SOLUTIONS

LIVE DEMONSTRATIONS

Page 39: FIRE RETARDANT SYSTEMS AND SOLUTIONS

FLOOR OPENING

Page 40: FIRE RETARDANT SYSTEMS AND SOLUTIONS
Page 41: FIRE RETARDANT SYSTEMS AND SOLUTIONS
Page 42: FIRE RETARDANT SYSTEMS AND SOLUTIONS
Page 43: FIRE RETARDANT SYSTEMS AND SOLUTIONS
Page 44: FIRE RETARDANT SYSTEMS AND SOLUTIONS

WALL OPENING

Page 45: FIRE RETARDANT SYSTEMS AND SOLUTIONS
Page 46: FIRE RETARDANT SYSTEMS AND SOLUTIONS

SOME INSTALLATIONS

Page 47: FIRE RETARDANT SYSTEMS AND SOLUTIONS

POWDER MIXED WITH WATER TO MAKE ATTA LIKE DOUGH

Page 48: FIRE RETARDANT SYSTEMS AND SOLUTIONS
Page 49: FIRE RETARDANT SYSTEMS AND SOLUTIONS

AT WANAKBORI TPS – WALL OPENING

Page 50: FIRE RETARDANT SYSTEMS AND SOLUTIONS
Page 51: FIRE RETARDANT SYSTEMS AND SOLUTIONS

WALL OPENING INSTALLATION AT BALCO

Page 52: FIRE RETARDANT SYSTEMS AND SOLUTIONS
Page 53: FIRE RETARDANT SYSTEMS AND SOLUTIONS

WALL OPENING INSTALLATION AT ADITYA BIRLA - ULTRATECH POWER PLANT OF AP CEMENT AT

TADAPATRI A.P.

Page 54: FIRE RETARDANT SYSTEMS AND SOLUTIONS
Page 55: FIRE RETARDANT SYSTEMS AND SOLUTIONS

FLOOR OPENING INSTALLATION AT RAICHUR TPS

Page 56: FIRE RETARDANT SYSTEMS AND SOLUTIONS
Page 57: FIRE RETARDANT SYSTEMS AND SOLUTIONS

OUR CLIENTSPOWER PLANTS

SRL CLIENT PLANT / LOCATION

1 Gujarat Electricity Board Wanakbori, Ukai, Gandhinagar TPS.

2 Rajasthan Electricity Board Kota TPS

3 Andhra Pradesh Electricity Board Vijaywada, Ramagundam TPS

4 Tamilnadu Electricity Board Kadampari (Hydro)

5 Nuclear Power Corporation Narora, Kakrapar, Kaiga & Kalpakkam. NFC & IGCAR

6 Bhakra Beas Management Board Nangal, Ganguwal & Kotla

Page 58: FIRE RETARDANT SYSTEMS AND SOLUTIONS

SRL CLIENT PLANT / LOCATION

7 M.P. State Electricity Board Sanjay Gandhi TPS, Birsinghpur.

8 Karnataka Power Corp. Ltd. Raichur TPS

9 Ahmedabad Elect. Co. Ltd. Sabarmati TPS, Vatva Gas

10 ---- DO --- Project Division Vijaywada TPS, Kothagundam TPS, Basin Bridge Gas, Jindal Tractbel gas

11 Gujarat Ind. Power Co. Ltd. Baroda, Mangrol

12 Tata Power Ltd Chembur, Sewri, Bhira, Khopoli

13 Rolls Royce Industrial Power Kakinada

Page 59: FIRE RETARDANT SYSTEMS AND SOLUTIONS

SRL CLIENT PLANT/ LOCATION

14 Crompton Greaves Ltd Godavari gas project

15 Neyveli Lignite Corp. Ltd. Neyveli

16 GE Power Kondapalli

17 BHEL Basin Bridge Gas Turbine, Vizag & Lehra Mohabbat

18 L & T IPCL Gandhar CPP, Usha Martin CPP

19 Tata Chemicals Okha

20 Thermax Torrent Power Plant

21 Gujarat Power Gen. Ltd. Bharuch

22 UB Engineering Ltd. Raichur TPS

Page 60: FIRE RETARDANT SYSTEMS AND SOLUTIONS

SRL CLIENT PLANT/ LOCATION

23 Tata Projects Ltd ACC Wadi TPS

24 BSES Ltd. GSECL CPP Dhuvaran

25 Wartsila Tata Power Belgaum

26 BALCO CPP [NTPC] Korba

CEMENT PLANTS

27 Ambuja Cement Kodinar, Ropar, Darlaghat

28 Maratha Cement Chandrapur

29 Vikram Cement Jawad

30 Ultra tech – Aditya Birla Chittorgarh, Tadapatri, Grasim, Hirmi

Page 61: FIRE RETARDANT SYSTEMS AND SOLUTIONS

SRL CLIENT PLANT/ LOCATION

31 ACC [Through L & T] Jamul, Kymore

32 Birla White Cement Kharia Khangar

FERTILIZER PLANTS

33 Gujarat State Fertilizer Co. Baroda, Sikka

34 National Fertilizer Nangal

35 Shriram Fertilizer Kota

36 Rourkela Fertilizer Rourkela

37 KRIBHCO CO-OP Ltd. Hazira

Page 62: FIRE RETARDANT SYSTEMS AND SOLUTIONS

SRL CLIENT PLANT/ LOCATION

PETRO CHEMICALS & REFINERIES

38 Indian Oil Corporation Ltd. Baroda, Panipat, Mathura

39 GACL Baroda

40 Numaligarh Refinery Numaligarh [ Through Blue Star]

41 Indian Petrochemicals Ltd. Baroda, Nagothane, Dahej

42 Gujarat heavy Chemicals Ltd. Veraval

43 Rayalseema Alkalies Rayalseema

44 Digboi Refinery [Thru L&T and BHPV]

DIGBOI

Page 63: FIRE RETARDANT SYSTEMS AND SOLUTIONS

SRL CLIENT PLANT/ LOCATION

PETRO CHEMICALS & REFINERIES

45 Chennai Petroleum [ thru L&T, Punj Lloyd, Nitson & Amitsu]

Chennai

46 IOCL [Panipat] thru L&T, Daelim Panipat

47 Deepak Nitrite Ltd. Nandesari - Vadodara

STEEL PLANTS

48 Steel Authority of India Ltd. Bhilai, Rourkela, Burnpur.

49 Essar Steel Hazira and Jamnagar

50 Rashtriya ispat Nigam Vishakhapatnam

51 Jindal Steel & Power Raigarh, Chhattisgarh

Page 64: FIRE RETARDANT SYSTEMS AND SOLUTIONS

SRL CLIENT PLANT/ LOCATION

THROUGH COMPANIES UNDER SUB-CONTRACT

52 Bells CEREBRUS Ltd., BHEL Bhilai

53 ABB, MUKAND, EPIL, SIEMENS, PHILIPS, ANDREW YULE, MECON

Rourkela

54 L & T TISCO, Jamshedpur

55 BHEL, MECON Vishakhapatnam

56 Llyod Insulation Ltd. Bhilai

57 Technico [ I ] Pvt. Ltd. TISCO, Jamshedpur

58 Mahati Electrics Pune Raichur TPS

59 Driplex Water Engg Ltd Neyveli Lignite

60 Ahluwalia Const India Ltd. Reliance Power, M.P.

Page 65: FIRE RETARDANT SYSTEMS AND SOLUTIONS

SRL CLIENT PLANT/ LOCATION

OTHERS

58 GRASIM Nagda

59 AMUL Dairy Anand - Gujarat

60 Heavy Water Plant Tuticorin, RCF, Alibaug

61 BHEL, ELECON Open Cast Mines, Ramagundam

62 Hotel LEELA Mumbai

63 Electrical Sub-stations Surat, CESC Kolkata, Asoj, Soja, Limdi, Kasor, Karamsad. MSTCL, Pune.