FIRE RATED CABLE FIRE RATED CABLE
Saving Lives !
Axyl Fire Performance Cables are manufactured and approved to meet the international standards for FIre System.Designed and Manufactured in UK, Axyl Cables are in compliance with international standards for Fire Resistance and Flame Retardance testing. Axyl Cables are approved and complies with Low Somoke & Zero Halogen Emission gases under fire condition.
All the details are printed on the cable along the entire length with time & date of manufacture and a unique quality assurance batch number for full traceability.
“ Easy Strip Sheath & Insulation | Save Installation time & Money ”
KEY BENEFITS
• Fast to Install with Superb Working Flexibility • Twisted Conductors for added data protection• Red,White & Black Outer Sheaths Available• 100m, 200m, 500m and Special lengths available• Conductor Size: 0.5mm2, 0.75mm2, 1.0mm2, 1.5mm2, 2.5mm2 & 4.0mm2• Aluminium Foil Screen for EMC Protection• Low Smoke & Zero Halogen• Voltage Rating 300V/500V• Supplied on Robust Black Reels.
LPCB Ref. 682e/01LPCB CER No. 682e-(cl-3)
Axyl Fire Cables are LPCB approved to BS 6387:2013 CWZ¤ C- 180 mnts at 950°C (upto ±40°C) fire only.¤ W- 30 mnts at 650°C (upto ±40°C) fire with water spray applied for final 15mnts.¤ Z- 15 mnts at 950°C (upto ±40°C) with fire & mechanical shock applied every 30 sec throughout the test
BS EN 50200:201530 mnts under fire conditions at 830ºC (upto ±40°C) with mechanical shock applied every 5 mnts to the same cable sample throughout the 30 mnt test.
BS EN 60754-1:2014-Zero Halogen EmissionsEmission of less than 0.5% of corrosive & acid gas when under fire conditions.
BS EN 61034-2:2005-Low Smoke EmissionMeeting at least 60% residual light transmission while cable is under fire conditions.
BS EN 60332-1-2 :2004Cable flame retardancy test for limiting propagation of fire.
Manufactured in United K ingdom
“The fastest fire cable to install”
www.exentureglobal.com [email protected] +971 4 320 6419
Manufactured in United K ingdom
Axyl Cables are available in a variety of multiple core combinationsand is available in 100m, 200m, 500m reels and other special lengthsare available.
Supplied On Robust Plastic Reels for : • Safe and Easy handling• Better Reeling and Damage resistant• Weather and Moisture resistant
Manufacturers Recommended Installation Guide Lines
Recommended metal clip spacing 300mm Horizontal and 400mm Vertical.Recommended Cable Tray Fastening - Metal Tie and spacing should be every 1.5 metres.
Installation Temperatures:Minimum installation Temperature : 0 °CMaximum installation Temperature : 70 °C
Operating Temperature:Minimum -40 °C to Maximum +90 °C.The cable should not be flexed or bent when either the cable or operatingtemperature is below therecommended minimum or above the maximum recommended installation temperatures.
Minimum Bend Radius = 6 x DiameterPlastic clips or ties must not be used as the sole means of support for fire cable.
Low Smoke Zero HalogenOuter Sheath
Solid Copper Conductor Cores
Polyester Backed Co polymer Aluminium Foil
Aluminum Foil, bonded tothe Outer Sheath
Fire ResistantLow Smoke Zero Halogen Silicone Insulation
0.8mm Drain Wire
Conductor Size All Cables have 0.80mm Drain Wire
1.00mm² = 1.13mm Dia AX-FP210-R100 AX-FP310-R100 AX-FP410-R1001.50mm² AX-FP215-R100 AX-FP315-R100 AX-FP415-R1002.50mm² AX-FP225-R100 AX-FP325-R100 AX-FP425-R100
White 2 Cores 3 Cores 4 Cores1.00mm² = 1.13mm Dia AX-FP210-W100 AX-FP310-W100 AX-FP410-W1001.50mm² AX-FP215-W100 AX-FP315-W100 AX-FP415-W1002.50mm² AX-FP225-W100 AX-FP325-W100 AX-FP425-W100
Red Sheath 2 Cores 3 Cores 4 Cores
* All conductors are solid Copper* Shown above is the nominal cross sectional area (r²) in mm² and the diameter in mm of the copper conductor Core.* Note: 3&4 Core Cable comes with suffix “/H”at the end i.e.- AX-FP315H, AX-FP415H
www.exentureglobal.com [email protected]
Manufactured in United K ingdom
Exenture Europe B.V.Starnmeerstraat 1-3, Hoofddorp | 2131 AE - NetherlandsTel : 0031235546043
Exenture Middle East FZCG-29, Technohub | Dubai Silicon OasisPO: 643812 | Dubai
Technical Specifications
LPCB Certified to Fire Resistance Standard EN 50200:2015Fire Resistance Standard BS 6387:2013 CWZHalogen Emission Standard EN 60754-1:2014Low Smoke Standard EN 61034-2:2005Single Cable Retardancy EN 60332-1-2:2004
Materials Conductors Plain Annealed CopperCore Installation Fire Resistant Ceramic SiliconeOuter Sheath Low Smoke HFFR Materials
Insulation Colour Code to Harmonised BS 7629-1:2015 Working Voltage Core to Core 500V
Core to Drain 300VTest Voltage 5,000V Types Outer Sheath Colours Red, White or Black
Number of Cores 2, 3 & 4 CoreInner Cores CSA - mm² 0.50, 0.75, 1.0, 1.5, 2.5 & 4.0mm² Nominal
Nominal Resistance 0.50mm² CSA 36.2 Ohms / 1 Km Maximum (+/- 5%) 0.75mm² CSA 24.6 Ohms / 1 Km
1.00mm² CSA 18.1 Ohms / 1 Km1.50mm² CSA 12.2 Ohms / 1 Km 2.50mm² CSA 7.50 Ohms / 1 Km
Minimum Bend Radius Radius = 6 x Diameter Operating Temp. Minimum/Maximum - 40°C to +90°C Installation Temp. Minimum/Maximum 0°C to +70°C Voltage Drop 0.50mm² CSA 83 Ohms mV / A / m (DC or Single Phase AC) 0.75mm² CSA 62 Ohms mV / A / m
1.00mm² CSA 44 Ohms mV / A / m1.50mm² CSA 29 Ohms mV / A / m2.50mm² CSA 18 Ohms mV / A / m
Approximate 2 Core 0.50mm² / TBCmm Overall Diameter 0.75mm² / TBCmm
1.00mm² / 6.7mm1.50mm² / 6.9mm2.50mm² / 7.9mm
3 Core 0.50mm² / TBCmm0.75mm² / TBCmm1.00mm² / TBCmm1.50mm² / TBCmm2.50mm² / TBCmm
4 Core 0.50mm² / TBCmm0.75mm² / TBCmm1.00mm² / TBCmm1.50mm² / TBCmm2.50mm² / TBCmm
Approximate 2 Core 0.50mm² TBC Kg / 100 m Weights 0.75mm² 6.9 Kg / 100 m
1.00mm² 7.9 Kg / 100 m1.50mm² 8.6 Kg / 100 m2.50mm² 13.5 Kg / 100 m
3 Core 0.50mm² TBC Kg / 100 m0.75mm² 8.2 Kg / 100 m1.00mm² 9.3 Kg / 100 m1.50mm² 12.6 Kg / 100 m2.50mm² 18.5 Kg / 100 m
4 Core 0.50mm² TBC Kg / 100 m0.75mm² 8.6 Kg / 100 m1.00mm² 10.3 Kg / 100 m1.50mm² 13.8 Kg / 100 m2.50mm² 21.5 Kg / 100 m
Current Rating Cable Clipped 0.50mm² TBC (Current Ratings listed are at 30°C (DC or Single Phase AC) 0.75mm² TBC Refer to BS7671/EE Wiring 1.00mm² 15A Regulations for de-rating factor.) 1.50mm² 19A
2.50mm² 27AEnclosed 0.50mm² TBC(DC or Single Phase AC) 0.75mm² TBC
1.00mm² 13A1.50mm² 16A2.50mm 23A
Capacitance Rating 0.75mm² CSA2 Core Core to Core - Average TBC3 Core 4 Core ~ Core to Core - Average TBC
1.5mm² CSA2 Core Core to Core - Average 70 pF/m3 Core 4 Core ~ Core to Core - Average 75 pF/m
2.5mm² CSA2 Core Core to Core - Average 80 pF/m3 Core4 Core ~ Core to Core - Average 85 pF/m
Va 186 Version:1.4 Issued: 03/01/2017