6
FIRE PUMP EXHAUST INSULATION: ENSURING UL 2000 COMPLIANCE Firwin Corp is a leading manufacturer of custom insulation products for diesel and gas engines, exhaust systems, and industrial applications.

FIRE PUMP EXHAUST INSULATION: ENSURING UL 2000 COMPLIANCE · 2020. 10. 25. · UL 2200 standard is the most applicable, as it lists the requirements for stationary engine generator

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FIRE PUMP EXHAUST INSULATION: ENSURING UL 2000 COMPLIANCE · 2020. 10. 25. · UL 2200 standard is the most applicable, as it lists the requirements for stationary engine generator

FIRE PUMP EXHAUST INSULATION: ENSURING UL 2000 COMPLIANCE

Firwin Corp is a leading manufacturer of custom insulation products for diesel and gas engines, exhaust systems, and industrial applications.

Page 2: FIRE PUMP EXHAUST INSULATION: ENSURING UL 2000 COMPLIANCE · 2020. 10. 25. · UL 2200 standard is the most applicable, as it lists the requirements for stationary engine generator

Fire Pump Exhaust Insulation: Ensuring UL 2000 Compliance

Firwin Corporation Email: [email protected] www.firwin.com

2

Follow Us:

WHAT IS A FIRE PUMP?Fire pumps are used to supply high pressure water flow to fire sprinkler safety systems. These systems are typically found in high-rise buildings, storage warehouses, or any area where the local municipal water system is not able to provide sufficient water pressure to the fire sprinkler system to be approved by a third-party testing agency like the Underwriters Laboratory (UL) to ensure that they will perform as expected. While fire pumps are typically electrically powered, they will also feature a backup power source, such as a diesel or gas engine, so that they will function during a power outage.

Due to the high temperatures generated by these engines, fire pump systems often require insulation blankets to cover the engine’s hot exhaust components, to protect personnel and

maintain a comfortable ambient heat in the area surrounding the fire pump system.

In this e-book, we’ll discuss UL standards, fire pump insulation, and how to keep your facility as safe as possible.

Page 3: FIRE PUMP EXHAUST INSULATION: ENSURING UL 2000 COMPLIANCE · 2020. 10. 25. · UL 2200 standard is the most applicable, as it lists the requirements for stationary engine generator

Fire Pump Exhaust Insulation: Ensuring UL 2000 Compliance

Firwin Corporation Email: [email protected] www.firwin.com

3

Follow Us:

UL LISTEDUnderwriters Laboratories is an independent body that inspects and certifies an expansive range of products by subjecting them to a comprehensive series of safety tests.

UL handles a wide variety of standards for industrial and construction equipment, so it’s important to know which standards apply to fire safety equipment. UL 2200 standard is the most applicable, as it lists the requirements for stationary engine generator assemblies.

Manufacturers have parts and components certified by UL to assure customers that the products are safe, operate as expected, and can meet the high-performance demands of fire safety situations. Conversely, a UL listing also shows buyers that the manufacturer operates at a higher standard in accordance with UL guidelines.

UL tests fire pumps and related equipment to make sure they can be relied upon in a fire emergency. Engines, couplings, pumps, and other critical fire equipment are each tested separately to

determine their efficacy and longevity in fire safety applications. Removable insulation blankets should also be UL approved, as

they are an integral part of any fire pump safety system.

Page 4: FIRE PUMP EXHAUST INSULATION: ENSURING UL 2000 COMPLIANCE · 2020. 10. 25. · UL 2200 standard is the most applicable, as it lists the requirements for stationary engine generator

Fire Pump Exhaust Insulation: Ensuring UL 2000 Compliance

Firwin Corporation Email: [email protected] www.firwin.com

4

Follow Us:

FIRE PUMP EXHAUST INSULATIONExposed engine and exhaust components from a fire pump’s engine can pose safety risks if left unprotected. The high temperatures generated by these engines run the risks of:

� Personnel injury due to contact with exposed engine and exhaust components

� High ambient heat around the area of the fire pump, making working conditions difficult or impossible

� Damage to heat-sensitive cables and sensors

To best protect against these risks, exposed engine components should be covered with insulation blankets. Removable insulation blankets can easily cover the exhaust and engine components to shield workers from direct contact and lower the ambient temperature in the space.

As part of the overall fire protection system, all insulation coverings need to meet the same safety standards as other fire safety equipment to keep your system UL-compliant; so it’s important that all removable insulation blankets meet UL 2200 requirements.

Ultimately, removable insulation blankets and covers are a vital part of any strategy

to maintain fire pump exhaust compliance, safety, and operation.

Page 5: FIRE PUMP EXHAUST INSULATION: ENSURING UL 2000 COMPLIANCE · 2020. 10. 25. · UL 2200 standard is the most applicable, as it lists the requirements for stationary engine generator

Fire Pump Exhaust Insulation: Ensuring UL 2000 Compliance

Firwin Corporation Email: [email protected] www.firwin.com

5

Follow Us:

FIRWIN’S FIRE PUMP INSULATION EXPERTISEAs a UL 2200-listed manufacturer, Firwin has a long history of successful fire pump insulation projects. You can find our removable insulation blankets on fire pump systems in department stores, high rises, and industrial facilities at hundreds of sites throughout North America. We start every project by giving you access to a generic fire pump exhaust drawing that can be easily modified to match your facility’s exhaust system. Our team can help adjust the fire pump drawing to ensure every relevant component is covered.

From this drawing, we can provide you with a fast and accurate quote that allows you to successfully anticipate the insulation component of the fire pump protection system. Our experience with different fire pump systems ensures we can give accurate estimates should you require a quote when there’s little information available about your facility’s system.

SPECIFY FIRWIN FOR YOUR NEXT FIRE PUMP INSULATION PROJECTIt’s important to make sure that all your Fire Pump System’s components meet UL 2200 standards. Firwin insulation blankets are UL 2200-compliant. Our experience with different fire pump systems ensures that we can give accurate estimates should you require a quote even when there’s little information yet available about your facility’s system.

Contact our team today to learn more about Firwin and our insulation blankets, or request a quote to get an accurate estimate from one of our expert technicians.

Page 6: FIRE PUMP EXHAUST INSULATION: ENSURING UL 2000 COMPLIANCE · 2020. 10. 25. · UL 2200 standard is the most applicable, as it lists the requirements for stationary engine generator

Firwin Corporation is a leading manufacturer of custom insulation products for diesel and gas engines & exhaust systems, and industrial applications. Our two main product lines are removable and reusable insulation blankets (also known as removable insulation covers and removable insulation jackets) and permanent Hard Coat™ composite insulation. We also stock a wide range of off-the-shelf high temperature tapes and sleeves.

We service a diverse range of industries, providing insulation solutions for applications such as diesel and gas powered generating stations, gensets, on-road and off-road vehicles, as well as industrial applications such as process and steam line valves, flanges, and piping.

Firwin Corporation 1685 Flint Road, Toronto, ON M3J 2W8 Toll Free: 1.877.347.9467 Tel: 416.745.9389 Fax: 416.745.0782 Email: [email protected] www.firwin.com

About Us

Request information about Firwin’s

Insulation Solutions

REQUEST INFORMATION >>