Upload
ozakyus
View
216
Download
0
Embed Size (px)
Citation preview
8/11/2019 fire dec
1/2
03 AUTOMATION
FIRE DETECTION UNITITDAC-14P-4
Fire detection system is one of the most important marine systems, since its functionality is directly connected with thesafety of people and equipment. As such, it must provide reliable notification of f ire and warn the responsible persons, inorder to prevent fire spreading and potential catastrophic consequences.
Inelteh's fire detection unit ITDAC-14P-4 features:
conventional fire detection system4 fire detection linesautomatic and/or manual alarm output activationseparate and independent outputs for crew and passengersoutputs 24V DC - fire bells can be directly connected
type approved by Croatian Register of Shipping
OUTPUT CONTACTfor VENTILATIONBLOCKING
MANUAL CALL
POINTS
IN CASE OF FIRE
BREAK GLASS
IN CASE OF FIRE
BREAK GLASS
SMOKE
DETECTORS
HEAT
DETECTORS
FIRE DETECTION UNIT
ITDAC-14P-4
OUTPUT FOR BELLS IN CREW'S AREA
OUTPUT FOR BELLS IN PASSENGERS' AREAPOWER SUPPLY: 24V DC
24V DC
24V DC
4 lines
LINE FAILURE
POWER
FAILURE
ALARM OUTPUT
ACTIVATED
POWER
TEST
ITDAC-14P-4FIRE DETECTION UNITRIJEKA - CROATIA
ALARMCREW
ALARMPASSENGERS
LINE 4
LINE 3
LINE 2
LINE 1
All dimensions are in mm.
FIRE DETECTION UNIT ITDAC-14P-4
power supply: 24V DC (18-32V DC) current consumption (without bells ): 200mA max. number of smoke and heat detectors in single line: 17 max. number of manual call points in single line is unlimited power failure signalization: LED + buzzer; built-in battery with automatic charging
output contact for ventilation blocking: Voltage-free contact 5A/250V AC, activated as long as one of f ire detectors is in alarm state and/or whenalarm output is manually activated
alarm output for crew: output 24V DC 1A max; activation: automatically (after 2 min if alarm isn't accepted) and/or manually alarm output for passengers: 24V DC 1A max; activation: manually flush (IP22, weight: 0.9kg) or bulkhead (IP54, weight: 7kg) mounting
ENGINEERING FOR ELECTRONIC EQUIPMENT AND SYSTEMS
144
300
320
144
300
260
DEPTH IS 107mm.
138
138 CONSOLE
CUT-OUT
30
1658
7xPG13.5+1xPG16
8/11/2019 fire dec
2/2
OPTICAL SMOKE DETECTOR
BELL CEADEL 165
power supply: 8.5-33V DC quick and reliable detection of smoke on the light scatter principle performs well in detecting black and white smoke with LED indication bulkhead mounting or wall mounting (on box with cable glands)
approved for use in marine environment by GL, DNV, BV, LR, ABS, CCS IP protection: according to EN 54-7:2000
MANUAL CALL POINT
conventional, with voltage-free contact and resistor elementtest-key for alarm simulation construction: ABS spare glass (on request) bulkhead mounting for indoor (IP42) or outdoor (IP66) use weight: 0.36kg (IP42 version) or 0.46kg (IP 66 version)
power supply: 24V DC current consumption: 0.3A sound pressure: 98dB / 1m IP protection: IP66 weight: 1.6kg
for applications where smoke detectors are unsuitable in environments that are dirty or smoky under normal conditions for temperature 65C or for temperature 80C (kitchen) power supply: 8.5-33V DC quick and reliable sensing of air temperature, using single thermis tor with LED indication bulkhead mounting or wall mounting (on box with cable glands) approved for use in marine environment by GL, DNV, BV, LR, ABS, CCS IP protection: according to EN 54-7:2000
HEAT DETECTOR
2xPG13.5
O6
220
204
120
82
for wall mounting
DEPTH: 132; WEIGHT: 0.7kg
All dimensions are in mm.
6.5
13
91
DEPTH: 76
IN CASE OF FIRE
BREAK GLASS
110 (for IP66)
110(forIP66)
87 (for IP42)
87(forIP42)
2xPG13.5
DEPTH: 53 (for IP42)
or 65 (for IP66)
O100
72
O5
52
for bulkhead mounting
WEIGHT: 0.14kg
Optical smoke and heatdetectors, dimensions:
Ljubljanska cesta 7, HR-51000 Rijeka / Croatia / tel. ++385 51 274 536 / fax 712 122 / [email protected] / www.inelteh.hr
O168