4
FIRE ALARM SYSTEMS

FIRE ALARM SYSTEMS - ALFAMAXeng.alfamax.com.tr/dosyalar/Alfamax_FireAlarm_English.pdf · 2016. 9. 5. · AXDZ-01 AX DB-01 Detector Base For l-1001, l-1002, l-1003, l-1004 dedectors

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • FIRE ALARM SYSTEMS

  • AXDZ-01AX DB-01 Detector Base

    For l-1001, l-1002, l-1003, l-1004 dedectors.

    l-1003Addressable Heat Detector

    Double Led

    l-1004Intelligent Ultraviolet Flame

    DetectorDetect a 3cm flame at 6 meters.

    l-1002Intelligent Multi SensorTwin LED for 360 vision

    l-1006Addressable Sounderallows easy installation

    l-1006 FAddressable Sounder and Strobe

    Strobe provided by high intensity LED cluster

    l-1005Adressable Manual Call Point

    Addressable Manual Call Point (MCP) with re-settable (non breakable) glass

    l-1001Addressable Optical (Photoelectric)

    Smoke DetectorDouble Led

    I-1050Addressable Sounder Circuit

    ModuleRegional siren operating or mute

    feature

    I-1051Intelligent Single Input/Output ModuleEnsures that all relay controls. Available

    with 220 volts.

    I-1054Isolator Module

    be used after each 20 detectorsIsolates a designated area

    I-1053Addressable Zone Monitor Unit

    15 Convetional dedectors to collectin one address

    I-1052Addressable Input Module

    Be connected device on / of the monitoring and contro module.

    l-1000-11 Loop Addressable Fire Alarm Panel

    l-1000-22 Loop Addressable Fire Alarm Panel

    l-1000-33 Loop Addressable Fire Alarm Panel

    l-1000-44 Loop Addressable Fire Alarm Panel

    • 240x123 Big Screen• 250x4 Address Capacity

    • 32 Zone, 2 Siren Line • Recessed and surface type mounting

    options

    l-1000-1RRepeater PanelCompatible Whit

    l-1000-1, l-1000-2, l-1000-3, l-1000-4

    Recessed and surface type mounting

    l-1007Addressable Natural Gas Detector

    24 VDC, Relay output

    l-1008Addressable LPG Gas Detector

    24 VDC, Relay output

    l-1009Addressable Carbon Monoxid Gas

    Detector24 VDC, Relay output

    ADDRESSABLEFIRE ALARM

    SYSTEMS

  • C-1005Conventional Manual Call Point

    Manual call Point (MCP) with re-set-table (non breaking) glass

    AXDZ-01Standard Detector Base

    For C-1002, C1003, C-1004

    C-1003Dual Convenctional Heat Detector

    Double Led

    C-1007Natural Gas Detector

    Gas-controlled, 12 / 24V DC or 220V AC supply, regional alarm

    signal and relay outputs.

    C-1008LPG Gas Detector

    LPG-controlled, 12 / 24V DC or 220V AC supply, regional alarm

    signal and relay outputs.

    C-1009Carbonmonoxide Gas Detector

    Carbonmonoxide controlled, 12 / 24V DC or 220V AC supply, regional alarm signal and relay

    outputs.

    C-1004Conventional Ultraviolet Flame detector

    Effective range 12 metres

    R-1003Relay Heat Increasing Speed Dedektörünormally closed contact N/C For security

    panels 24V and 48V

    ALP-01Remote indicator

    detector which is used for all types of output for indicator.

    ALP-00Detector Protection CoverCleaning and the paint effect

    be used for protection be used for protection.

    C-1002Conventional Multi Sensor

    Smoke+Heat DetectorDouble Led

    R-1002Relay Multi Sensor

    Smoke + Dual Heat DetectorDouble Led

    C-1001Conventional Optical Smoke Detector

    Double Led

    R-1001Relay Optical Smoke Detector

    Double led

    C-1006Conventional Sounder

    12V/ 24V/ 220V options.

    C-1006 FConventional Sounder and Strobe

    12V/ 24V/ 220V options.

    C-1000-4 / 4 Zonlu Conventional Fire Alarm PanelC-1000-8 / 8 Zonlu Conventional Fire Alarm PanelC-1000-16/16 Zonlu Conventional Fire Alarm Panel

    2 siren outputs, testing and discharge day / night mode setting, normal, error status, alarm display cases, short circuit and open circuit alarm and replace the identified regional identifying feature of external connec-tions, standard relay outputs.

    C-1000-4R / 4 Zonlu Conventional Fire Alarm PanelC-1000-8R / 8 Zonlu Conventional Fire Alarm PanelC-1000-16R / 16 Zonlu Conventional Fire Alarm Panel

    2 siren outputs, testing and discharge day / night mode setting, normal, error status, alarm display cases, short circuit and open circuit alarm and replace the identified regional identifying feature of external connections, standard relay outputs.

    CONVENTIONALFIRE ALARM

    SYSTEMS

  • EMERGENCYDIRECTION AND

    LIGHTING SYSTEMS

    ECON X - ABSEmergency direction armature, double-face, working in an emergency, 3 hours working time, the ABS heat-resistant decorative body, long lasting battery, LED, flashing warning feature of a power failure.

    LIFE X400 x 265 x 25.5 mm - 644 grEmergency Lighting, continuous and urgent work options, long-lasting battery, LED transparent plexyglass.

    LIFE X (Recessed)400 x 265 x 25.5 mm Emergency Lighting, continuous and urgent work options, long-lasting battery, LED transparent plexyglass.

    BRIGHT - XSurface Mounted Emergency Lighting FixtureWorking in emergency, 3 hours working time, plaster ceiling and wall mounting, ABS heat resistant decorative body, long-life nickel metal hydride battery.

    BRIGHT - XRecessed Emergency Lighting FixtureWorking in emergency, 3 hours working time, flush ceiling or wall mounting, ABS heat-resistant decorative body, long-life nickel metal hydride battery.

    SPOT XSpot Lighting ArmaturePainted metal case, ceiling and wall mounting facilities, inluded lights, moving spotlights, LED emer-gency battery fault warning.

    2 x 20W in emergency mode 1 hour2 x 20W in emergency mode 3 hours2 x 50W in emergency mode 1 hour2 x 20W in emergency mode 3 hours

    BRIGHT - X (Large Size)Surface Mounted Emergency Lighting FixtureSleek, ergonomic design, wall and ceiling mounting feature easy-open closures, ABS heat-resistant decorative body, 3 hours of power loss feature.

    ww

    w.a

    ticon

    cept

    .net