6” WIDE BASE COAT,
FABRIC AND BASE COAT
COMPONENTS
continuous cleat
FLAT PROFILE
PRE-FINISHED METAL EDGE
FLASHING ATTACHED WITH
COATED SCREWS
@ 3” O.C. STAGGERED
12” WIDE BASE COAT AND BASE COAT
COMPONENTS
BASE COAT, FABRIC, AND BASE COAT
COMPONENTS FROM FIELD OF ROOF.
12"
6"
FINISH COAT COMPONENT OVER ENTIRE
ROOF (COLOR AS SPECIFIED)
NOTES:
1. ALL FLASHING SHALL BE DESIGNED FOR THE APPLICABLE ROOF CONDITIONS. METAL THICKNESS, FASTENERS, AND LAPPING
SHALL BE AS SPECIFIED BY THE ROOF DESIGNER.
2. REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR SPECIFIC EXECUTION REQUIREMENTS.
WALL
ROOF DECKING
INSULATION
3. FLUID APPLIED RESTORATION SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT COMPONENTS
4. BASE COAT – COMBINED COVERAGE (2 COATS) AT minimum rate as directed in the specification.
5. EACH FINISH COAT SHALL BE APPLIED AT THE PRODUCT DATA SHEET RECOMMENDATIONS. ALLOW TO DRY BETWEEN COATS.
6. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS
note: NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID
APPLIED SYSTEM GUIDE SPECIFICATIONS AT www.tropicalroofingproducts.com
STANDARD DRIP EDGE DETAIL DETAIL NO :
DATE :
12-13-16FLUID APPLIED RESTORATION COATING SYSTEM
1disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
12"6” WIDE BASE COAT,
FABRIC AND BASE COAT
COMPONENTS
6"
METAL GUTTER AND
SUPPORT BRACKETS
BASE COAT, FABRIC, AND BASE COAT
COMPONENTS
BASE COAT, FABRIC, AND BASE COAT
COMPONENTS FROM FIELD OF ROOF.
FLAT PROFILE
PREFINISHED METAL EDGE
FLASHING ATTACHED WITH
COATED SCREWS @ 3” O.C.
STAGGERED
continuous cleat
FINISH COAT COMPONENT OVER ENTIRE
ROOF (COLOR AS SPECIFIED)
WALL
ROOF DECKING
INSULATION
NOTES:
1. ALL FLASHING SHALL BE DESIGNED FOR THE APPLICABLE ROOF CONDITIONS. METAL THICKNESS, FASTENERS, AND LAPPING SHALL BE
AS SPECIFIED BY THE ROOF DESIGNER.
2. REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR SPECIFIC EXECUTION REQUIREMENTS.
3. FLUID APPLIED RESTORATION SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT COMPONENTS
4. BASE COAT – COMBINED COVERAGE (2 COATS) AT minimum rate as directed in the specification.
5. EACH FINISH COAT SHALL BE APPLIED AT THE PRODUCT DATA SHEET RECOMMENDATIONS. ALLOW TO DRY BETWEEN COATS.
6. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS
note: NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
GUTTER WITH STANDARD DRIP EDGE DETAIL DETAIL NO :
DATE :
12-13-16FLUID APPLIED RESTORATION COATING SYSTEM
2disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
wall
concrete
roof deck
8"
base coat, 12" fabric, and
base coat components
cover entire
exposed edge
note: STRUCTURAL CONCRETE MUST BE
CURED AT LEAST 28 DAYS. REFER TO
CONCRETE MANUFACTURER CURING TIME.
NOTES:
1. ALL FLASHING SHALL BE DESIGNED FOR THE
APPLICABLE ROOF CONDITIONS. METAL
THICKNESS, FASTENERS, AND LAPPING SHALL BE
AS SPECIFIED BY THE ROOF DESIGNER.
2. REFER TO TROPICAL ROOFING PRODUCTS
SPECIFICATIONS FOR SPECIFIC EXECUTION
REQUIREMENTS.
3. FLUID APPLIED RESTORATION SYSTEM – BASE
COAT, REINFORCED FABRIC, BASE COAT 2, AND
FINISH COAT COMPONENTS
4. BASE COAT – COMBINED COVERAGE (2 COATS) AT
minimum rate as directed in the specification.
5. EACH FINISH COAT SHALL BE APPLIED AT THE
PRODUCT DATA SHEET RECOMMENDATIONS. ALLOW
TO DRY BETWEEN COATS.
6. PRIMING – REFER TO TROPICAL ROOFING
PRODUCTS SPECIFICATIONS FOR DECK PRIMING
REQUIREMENTS
note: NOTE: FOR SPECIFIC PRODUCT
RECOMMENDATION REFER TO THE APPROPRIATE
FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
lap premium coat system
components from the roof
field over edge detail
fluid applied
restoration system:
base coat, 40"
fabric, base coat 2,
and finish coat over
entire roof deck.
DETAIL NO :
DATE :
12-13-16FLUID APPLIED RESTORATION COATING SYSTEM
3STANDARD STRUCTURAL CONCRETE ROOF DECK EDGE DETAIL
WITHOUT METAL DRIP EDGEdisclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
#932 fabric
deck joints
deck material with
staggered joints
6" minimum strip over
all deck joints
a. base coat over joint
b. reinforcing fabric
centered on joint
c. finish coat over fabric
DECK JOINT STRIPPING DETAIL
FINISH COAT COMPONENT,
COLOR AS SPECIFIED.
base coat 2
base coat
1. PREPARE ALL SURFACES IN
ACCORDANCE WITH THE
MANUFACTURER’S REQUIREMENTS.
2. ALL JOINTS SHALL BE TIGHT AND
STABLE. ALL FASTENERS SHALL BE
FLUSH WITH THE DECK.
3. FLUID APPLIED RESTORATION
SYSTEM – BASE COAT, REINFORCED
FABRIC, BASE COAT 2, AND FINISH
COAT COMPONENTS
4. BASE COAT – COMBINED
COVERAGE (2 COATS) AT MINIMUM
RATE as directed in the
specification.
5. EACH FINISH COAT SHALL BE APPLIED
AT THE PRODUCT DATA SHEET
RECOMMENDATIONS. ALLOW TO DRY
BETWEEN COATS.
6. PRIMING – REFER TO TROPICAL
ROOFING PRODUCTS SPECIFICATIONS
FOR DECK PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT
RECOMMENDATION REFER TO THE
APPROPRIATE FLUID APPLIED SYSTEM
GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
NOTES:
DECK JOINT STRIPPING DETAIL DETAIL NO :
DATE :
12-13-16FLUID APPLIED RESTORATION COATING SYSTEM
4disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
optional metal coping assembly
install entire system completely
over top of parapet
finish coat over entire roof
base coat, fabric, base coat
components
center 12" wide base coat, #932
fabric, and base coat components
over cant strip
existing roof deck and
insulation systems with or
without cant strip
roof drain shall be installed as
required by manufacturer
fluid applied coating system:
base coat, fabric, base coat
2, and finish coat
roof decking
tapered insulationbase coat, fabric, base coat
components
1. ROOFING MEMBRANE SHALL EXTEND UNDER THE ROOF DRAIN COMPRESSION CLAMPING RING.
2. SLOPE INSULATION TOWARDS DRAIN.
3. FLUID APPLIED RESTORATION SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT COMPONENTS
4. BASE COAT – COMBINED COVERAGE (2 COATS) AT minimum rate as directed in the specification.
5. EACH FINISH COAT SHALL BE APPLIED AT THE PRODUCT DATA SHEET RECOMMENDATIONS. ALLOW TO DRY BETWEEN COATS.
6. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.
note: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
NOTES:
Drain clamp ring must be
removed, sealed add
reinstalled with #950/951
Mastic (acrylic) or #9100
Mastic (silicone)
STANDARD PARAPET & ROOF DRAIN DETAIL DETAIL NO :
DATE :
12-13-16FLUID APPLIED RESTORATION COATING SYSTEM
5disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
36"
mechanical exhaust fan unit
fan curb at minimum of 8" above
roof line
finish coat component over
entire roof. color as specified
fluid applied coating
system: base coat, fabric,
base coat 2, and finish coat
12" base coat, fabric and
base coat components
roof deck
construction
exhaust fan unit
mounted on roof
36"TYPICAL
NOTES:
1. THIS DETAIL IS A TYPICAL FLASHING DETAIL AT EXHAUST FANS FOR COOKING.
2. PREPARE THE ROOF SURFACE AS PER MANUFACTURER’S REQUIREMENTS PRIOR TO APPLICATION OF ROOF COATING.
3. REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR SPECIFIC EXECUTION REQUIREMENTS.
4. FLUID APPLIED RESTORATION COATING SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT COMPONENTS
5. BASE COAT – COMBINED COVERAGE (2 COATS) AT minimum rate as directed in the specification.
6. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
section plan
TYPICAL EXHAUST FAN (FOR COOKING) FLASHING DETAIL
DETAIL NO :
DATE :
12-13-16FLUID APPLIED RESTORATION COATING SYSTEM
7disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
existing metal
roofingfinish coat. color
as specified.
metal primer
fluid applied coating system
overlap at gutter seams
vertical sides
GUTTER SEAM BOTTOM
SECTION
NOTES:
existing metal
gutter
1. PREPARE ALL GUTTER SURFACES AS REQUIRED BY FLUID APPLIED SYSTEM MANUFACTURER.
2. PRIME ENTIRE GUTTER WITH #960 METAL PRIMER @ 200 SF/GAL MINIMUM COVERAGE.
3. REMOVE LOOSE OR DAMAGES FASTENERS AND REPLACE WITH FASTENERS DESIGNED TO PENETRATE THE DECK AND SUPPORTING MEMBERS WITH NEOPRENE WASHERS
AT THE SCREW HEAD.
4. GUTTER CONFIGURATIONS MAY DIFFER FROM THE PROFILE INDICATED, BUT THE APPLICATION SHALL REMAIN SIMILAR.
5. FLUID APPLIED RESTORATION COATING SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT COMPONENTS. ALL GUTTER SEAMS ARE TREATED
WITH BASE COAT AND 4” OR 6” FABRIC DEPENDING ON GUTTER PROFILE. ALL FASTENERS ARE TREATED With #950/951 (acrylic) or #9100 (silicone).
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT www.tropicalroofingproducts.com
gutter plan
TYPICAL GUTTER DETAIL DETAIL NO :
DATE :
12-13-16FLUID APPLIED RESTORATION COATING SYSTEM
8disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
deck fastener
install #950/951 MASTIC ON
ACRYLIC OR #9100 SILICONE MASTIC
over every screw
vertical seam base coat,
fabric(4", 6", or 8"), base
coat 2
finish coat. color
as specified
metal roof deck
horizontal seam base coat,
fabric (12") and base coat 2
NOTES:
1. PREPARE ALL ROOF SURFACES AS REQUIRED BY THE FLUID APPLIED SYSTEM MANUFACTURER.
2. IF RUST IS PRESENT, REMOVE SURFACE RUST AND PRIME WITH #960 METAL PRIMER @ coverage indicated in specification for acrylic
restoration systems. Silicone can be applied directly over metal after surface rust is removed.
3. REMOVE LOOSE OR DAMAGED FASTENERS AND REPLACE WITH FASTENERS DESIGNED TO PENETRATE THE DECK AND SUPPORTING MEMBERS
WITH NEOPRENE WASHERS AT THE SCREW HEAD.
4. DECK CONFIGURATIONS MAY DIFFER FROM THE DECK PROFILE INDICATED, BUT THE APPLICATION SHOULD REMAIN SIMILAR.
5. FLUID APPLIED RESTORATION COATING SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT COMPONENTS. ALL
VERTICAL SEAMS ARE TREATED WITH BASE COAT AND 4”, 6” OR 8” FABRIC DEPENDING ON ROOF PROFILE. HORIZONTAL SEAMS ARE COVERED
WITH 12” FABRIC AND BASE COAT. ALL FASTENERS ARE TREATED WITH____
6. BASE COAT – COMBINED COVERAGE (2 COATS) AT MINIMUM RATE as directed in the specification.
7. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
DETAIL NO :
DATE :
12-13-16FLUID APPLIED RESTORATION COATING SYSTEM
TYPICAL METAL ROOF JOINT DETAIL9
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
3" 3"
MIN. MIN.
METAL ROOFING DECK
SECTION
NOTES:
1. PREPARE ALL ROOF SURFACES AS REQUIRED BY THE FLUID APPLIED SYSTEM MANUFACTURER
2. IF RUST IS PRESENT, PRIME ENTIRE ROOF WITH #960 PRIMER @ 200 SF/GAL MIN. COVERAGE
3. REMOVE LOOSE OR DAMAGED FASTENERS AND REPLACE WITH FASTENERS DESIGNED TO PENETRATE THE DECK AND SUPPORTING MEMBERS
WITH NEOPRENE WASHERS AT THE SCREW HEAD.
4. DECK CONFIGURATIONS MAY DIFFER FROM THE DECK PROFILE INDICATED, BUT THE APPLICATION SHALL REMAIN SIMILAR.
5. FLUID APPLIED RESTORATION COATING SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT COMPONENTS. ALL
VERTICAL SEAMS ARE TREATED WITH BASE COAT AND 4”, 6” OR 8” FABRIC DEPENDING ON ROOF PROFILE. HORIZONTAL SEAMS ARE COVERED
WITH 12” FABRIC AND BASE COAT. ALL FASTENERS ARE TREATED WITH #950/951 Mastic (acrylic) or #9100 Mastic (silicone)
6. BASE COAT – COMBINED COVERAGE (2 COATS) AT A MINIMUM RATE as directed in the specification.
7. EACH FINISH COAT SHALL BE APPLIED AT THE PRODUCT DATA SHEET RECOMMENDATIONS. ALLOW TO DRY BETWEEN COATS.
8. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING
REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
FINISH COAT COMPONENT,
COLOR AS SPECIFIED.
FINISH COAT COMPONENT OVER
ENTIRE ROOF (COLOR AS SPECIFIED)
10SECTION AT METAL PANEL SEAM DETAIL DETAIL NO :
DATE :
12-13-16FLUID APPLIED RESTORATION COATING SYSTEM
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
ROOF DRAIN. NOTE: ROOF
DRAIN SHALL BE INSTALLED AS
REQUIRED BY THE
MANUFACTURER.
ROOF DECKING
TAPERED
INSULATION
FLUID APPLIED
RESTORATION SYSTEM
– BASE
COAT, REINFORCED
FABRIC, BASE COAT 2,
AND FINISH COAT
COMPONENTS
NOTES:
1. ROOFING MEMBRANE SHALL
EXTEND UNDER THE ROOF DRAIN
COMPRESSION CLAMPING RING.
2. ALL DRAIN COMPONENTS SHALL
BE MADE OF CAST IRON UNLESS
APPROVED BY THE ROOF
MEMBRANE MANUFACTURER
TO USE ANOTHER MATERIAL.
3. SLOPE INSULATION TOWARDS
DRAIN.
4. FLUID APPLIED RESTORATION
SYSTEM – BASE COAT,
REINFORCED FABRIC, BASE COAT
AND FINISH COAT
COMPONENTS
5. BASE COAT – COMBINED
COVERAGE (2 COATS) AT A
MINIMUM RATE as directed in
the specification.
6. EACH FINISH COAT SHALL BE
APPLIED AT THE PRODUCT DATA
SHEET RECOMMENDATIONS. ALLOW
TO DRY BETWEEN COATS.
7. PRIMING – REFER TO TROPICAL
ROOFING PRODUCTS
SPECIFICATIONS FOR DECK
PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT
RECOMMENDATION REFER TO THE
APPROPRIATE FLUID APPLIED SYSTEM
GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
DETAIL NO :
DATE :
12-13-16FLUID APPLIED RESTORATION COATING SYSTEM
STANDARD ROOF DRAIN DETAIL11
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
ISOMETRIC VIEW
ROOF PARAPET
AT CORNER
12” X 12” REINFORCING
FABRIC, CUT TO FIT
INTO CORNER.
TAKE CUT UP TO TOP
OF CANT DIMENSION
TOP OF FABRIC
START OF CUT
REINFORCING FABRIC,
CUT TO FIT TIGHT AT
CANT AND TO
OVERLAP ON ROOF.
NOTES:
1. FLUID APPLIED RESTORATION
SYSTEM – BASE COAT, REINFORCED
FABRIC, BASE COAT 2, AND FINISH
COAT COMPONENTS
2. BASE COAT – COMBINED
COVERAGE (2 COATS) AT A MINIMUM
RATE as directed in the
specification.
3. EACH FINISH COAT SHALL BE APPLIED AT
THE PRODUCT DATA SHEET
RECOMMENDATIONS. ALLOW TO
DRY BETWEEN COATS.
4. PRIMING – REFER TO TROPICAL ROOFING
PRODUCTS SPECIFICATIONS FOR DECK
PRIMING
REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT
RECOMMENDATION REFER TO THE
APPROPRIATE FLUID APPLIED SYSTEM GUIDE
SPECIFICATIONS AT
www.tropicalroofingproducts.com
DETAIL NO :
DATE :
12-13-16FLUID APPLIED RESTORATION COATING SYSTEM
TYPICAL ROOF CANT (AT CORNER) FLASHING DETAIL 12
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
TERMINATION OF MEMBRANE FLASHING WILL VARY
SHEET METAL SCUPPER
SOLDERED/WELDED – SECURED TO WALL AND
DECK OR OPTIONAL WOOD BLOCKING.
FINISH COAT OVER ENTIRE ROOF. COLOR AS
SPECIFIED.
BASE COAT, FABRIC, BASE COAT COMPONENTS
ROOF DECK
SHEET METAL
CONDUCTOR HEAD
1” M
INIM
UM
BELOW S
CUP
PER
BOTTOM
INSTALL APPROPRIATE SEALANT AND
TOOL TO FACILITATE WATER RUNOFF.
fLUID APPLIED RESTORATION SYSTEM
BASE COAT, REINFORCED FABRIC,
BASE COAT 2, AND FINISH COAT
COMPONENTS
NOTES:
1. PRIMING – REFER TO TROPICAL ROOFING
PRODUCTS SPECIFICATIONS FOR DECK PRIMING
REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION
REFER TO THE APPROPRIATE FLUID APPLIED
SYSTEM GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
#950/951 Mastic
(acrylic) or #9100
Mastic (silicone) to
seal cap sheet
edge to scupper.
DETAIL NO :
DATE :
12-13-16
13STANDARD SCUPPER DETAIL
FLUID APPLIED RESTORATION COATING SYSTEM
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
ALSO SEE DETAIL 14b
FOR ISOMETRIC VIEW
1.
2.
STANDARD FLUID
APPLIED ROOF
SYSTEM
STORM COLLAR, IF
REQUIRED.
FINISH COAT OVER
ENTIRE ROOF.
BASE COAT, FABRIC,
AND BASE COAT
COMPONENTS.
6" min.
BASE COAT, 12” FABRIC, AND
BASE COAT COMPONENTS.
PLACE ADDITIONAL LAYERS
OF REINFORCING FABRIC AT
PENETRATION BASE, AS
SHOWN ON PLAN HERE AND
ON “ISOMETRIC VIEW” ON
DETAIL 14b.
BASE COAT, FABRIC,
AND BASE COAT
COMPONENTS.
ROOF DECK AND
INSULATION SYSTEM.
METAL OR PLASTIC VENT PIPE
PENETRATING ROOF MEMBRANE.
SECTION
plan
NOTES:
1. THIS DETAIL IS A TYPICAL
PENETRATION DETAIL
APPLICABLE FOR ALL COLD
PIPE PENETRATIONS. FOR
HOT PIPE PENETRATIONS
CONTACT THE MANUFACTURER
FOR REQUIREMENTS.
2. FOR PIPE PENETRATIONS
THAT EXCEED 18” ABOVE THE
ROOF SURFACE A STORM
COLLAR SHALL BE USED WITH
A DRAW BAND AND
CAULKING. THE ROOF
COATING SHALL
EXTEND 8” (MIN) UP
PENETRATION SURFACE.
3. FLUID APPLIED RESTORATION
COATING SYSTEM – BASE
COAT, REINFORCED FABRIC,
BASE COAT 2, AND FINISH
COAT COMPONENTS.
4. PRIMING – REFER TO
TROPICAL ROOFING
PRODUCTS SPECIFICATIONS
FOR DECK PRIMING
REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT
RECOMMENDATION REFER TO THE
APPROPRIATE FLUID APPLIED
SYSTEM GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
12"x12" reinf.
fabric over pipe
wrap
reinforcing
fabric pipe wrap
DETAIL NO :
DATE :
12-13-16
14aTYPICAL VENT PIPE FLASHING DETAIL
FLUID APPLIED RESTORATION COATING SYSTEM
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
REINFORCING
FABRIC PIPE WRAP
12” X 12” REINFORCING
FABRIC WITH PIPE
HOLE IN CENTER
pipe through
roof deck
1.2.
1.6"
hig
h
min
imum
REINFORCING
FABRIC PIPE WRAP
isometric view
2. LAYER
OF 12’ X 12” REINFORCING
FABRIC OVER PIPE WRAP
note: also see detail 14A
NOTES:
1. FLUID APPLIED RESTORATION
SYSTEM – BASE
COAT, REINFORCED FABRIC,
BASE COAT 2, AND FINISH COAT
COMPONENTS
2. PRIMING – REFER TO TROPICAL
ROOFING PRODUCTS
SPECIFICATIONS FOR DECK
PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT
RECOMMENDATION REFER TO THE
APPROPRIATE FLUID APPLIED
SYSTEM GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
DETAIL NO :
DATE :
12-13-16TYPICAL VENT PIPE FLASHING DETAIL
FLUID APPLIED RESTORATION COATING SYSTEM
14bdisclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
VENT / STACK PIPE
FLAT METAL PIPE
FLASHING
RUBBER CASING12” WIDE FABRIC
AND BASE COAT
(2 COATS) SPLICED
OVER FLAT METAL
FLASHING. COLOR
AS SPECIFIED.
VENT / STACK PIPE
RUBBER CASING
plan
SECTION
FLUID APPLIED RESTORATION
COATING SYSTEM – BASE
COAT, REINFORCED FABRIC,
BASE COAT 2, AND FINISH COAT
COMPONENTS.
FLAT METAL PIPE
FLASHING
NOTES:
1. ALL FLASHING SHALL BE DESIGNED
FOR THE APPLICABLE CONDITIONS.
METAL THICKNESS, FASTENERS, AND
LAPPING SHALL BE AS SPECIFIED BY
THE ROOF DESIGNER.
2. REFER TO THE SPECIFICATIONS FOR
SPECIFIC REQUIREMENTS.
3. FLUID APPLIED RESTORATION
COATING SYSTEM – BASE
COAT, REINFORCED FABRIC, BASE
COAT 2, AND FINISH COAT
COMPONENTS.
4. PRIMING – REFER TO TROPICAL
ROOFING PRODUCTS SPECIFICATIONS
FOR DECK PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT
RECOMMENDATION REFER TO THE
APPROPRIATE FLUID APPLIED SYSTEM
GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
16DETAIL NO :
DATE :
12-13-16VENT STACK PIPE DETAIL
FLUID APPLIED RESTORATION COATING SYSTEM
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
MECHANICAL EQUIPMENT
EQUIPMENT CURB AT
MIN. OF 8” ABOVE ROOF LINE
FINISH COAT COMPONENT OVER ENTIRE
ROOF. COLOR AS SPECIFIED.
FLUID APPLIED RESTORATION COATING
SYSTEM – BASE COAT, FLUID APPLIED
RESTORATION COATING SYSTEM – BASE
COAT, REINFORCED FABRIC, BASE COAT
2, AND FINISH COAT COMPONENTS.
12” BASE COAT FLUID APPLIED
RESTORATION COATING SYSTEM – BASE
COAT, REINFORCED FABRIC, BASE COAT
2, AND FINISH COAT COMPONENTS.
ROOF DECK
CONSTRUCTION
EQUIPMENT UNIT
MOUNTED ON ROOF
36"
TYPICAL
NOTES:
1. THIS DETAIL IS A TYPICAL FLASHING
DETAIL AT EQUIPMENT CURBS
2. PREPARE THE ROOF SURFACE AS
PER MANUFACTURERS
REQUIREMENTS PRIOR TO
APPLICATION OF ROOF COATING
3. REFER TO THE SPECIFICATIONS FOR
SPECIFIC REQUIREMENTS.
4. FLUID APPLIED RESTORATION
COATING SYSTEM – BASE
COAT, REINFORCED FABRIC, BASE
COAT 2, AND FINISH COAT
COMPONENTS.
5. PRIMING – REFER TO TROPICAL
ROOFING PRODUCTS
SPECIFICATIONS FOR DECK PRIMING
REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT
RECOMMENDATION REFER TO THE
APPROPRIATE FLUID APPLIED SYSTEM
GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
17DETAIL NO :
DATE :
12-13-16TYPICAL EQUIPMENT CURB FLASHING DETAIL
FLUID APPLIED RESTORATION COATING SYSTEM
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
FINISH COAT COMPONENT
OVER ENTIRE ROOF. COLOR
AS SPECIFIED.
BASE COAT, REINFORCED
FABRIC, AND BASE COAT
COMPONENTS.
4"
MIN
SHEET METAL FLASHING.
EPDM Flashing can also be used.
ROOF DECKING
INSULATION
ROOF E.J. CURB
NOTES:
1. PREPARE THE ROOF SURFACE AS PER MANUFACTURERS REQUIREMENTS
2. SHEET METAL FLASHING AND EXPANSION JOINT DESIGN PROFILE TO BE DETERMINED BY ROOF DESIGNER
3. FLUID APPLIED RESTORATION COATING SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH
COAT COMPONENTS.
4. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE
SPECIFICATIONS AT www.tropicalroofingproducts.com
DETAIL NO :
DATE :
12-13-16EXPANSION JOINT FLASHING DETAIL
FLUID APPLIED RESTORATION COATING SYSTEM
18disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
6"
MIN
6"
MIN
12” WIDE (MIN) BASE
COAT, REINFORCING FABRIC,
AND BASE COAT COMPONENTS
OVER EXISTING JOINT.
FLUID APPLIED RESTORATION
COATING SYSTEM – BASE
COAT, REINFORCED FABRIC,
BASE COAT 2, AND FINISH COAT
COMPONENTS.
ROOF DECK
INSULATION
NOTES:
1. FLUID APPLIED RESTORATION COATING SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT
COMPONENTS
2. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE
SPECIFICATIONS AT www.tropicalroofingproducts.com
EXISTING EXPANSION JOINT
SHEET METAL OVER JOINT,
ADHERED AT ONE SIDE ONLY
19DETAIL NO :
DATE :
12-13-16ROOF EXPANSION JOINT DETAIL
FLUID APPLIED RESTORATION COATING SYSTEM
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
BASE COAT.
ridge cap
TROPICAL #950/951 MASTIC
FOR ACRYLIC. OR, Tropical
#9100 MASTIC FOR SILICONE
REINFORCED
FABRIC.
metal roof panel
BACKING
4" 4"
NOTES:
1. BACKING CAN BE POLYURETHANE FOAM.
2. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK
PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID
APPLIED SYSTEM GUIDE SPECIFICATIONS AT www.tropicalroofingproducts.com
FINISH COAT. COLOR AS SPECIFIED.
20DETAIL NO :
DATE :
RIDGE CAP DETAIL
FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
6" h
igh
minimum
sheet metal rib cap
fasteners
RIB CAPS INSTALLED OVER TROPICAL
#950/951 MASTIC FOR ACRYLIC OR,
TROPICAL #9100 MASTIC FOR SILICONE.
NOTES:
1. RIB CAPS ARE REQUIRED OVER
BROKEN RIBS; AFTER INSTALLED,
SEAL THE RIB CAP PERIMETER AND
FASTENERS WITH TROPICAL #950/951
MASTIC FOR ACRYLIC OR, TROPICAL
#9100 MASTIC FOR SILICONE.
2. PRIMING – REFER TO TROPICAL
ROOFING PRODUCTS SPECIFICATIONS
FOR DECK PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT
RECOMMENDATION REFER TO THE
APPROPRIATE FLUID APPLIED SYSTEM
GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
21DETAIL NO :
DATE :
RIB CAP DETAIL
FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
metal rake
metal wall panel
metal roof panel
NOTES:
1. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS
SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE
APPROPRIATE FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
FINISH COAT. COLOR AS SPECIFIED.
BASE COAT.
TROPICAL #950/951 MASTIC FOR
ACRYLIC. OR, TROPICAL #9100
MASTIC FOR SILICONE.
6” OR 12” FABRIC FULLY EMBEDDED IN
TROPICAL #950/951 MASTIC FOR
ACRYLIC OR, TROPICAL #9100 MASTIC
FOR SILICONE.
22DETAIL NO :
DATE :
FLOATING RAKE
FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
8"
min
.
4"
min
. 2"
min
.
unlim
ited
heig
ht
NOTES:
1. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS
SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER
TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE
SPECIFICATIONS AT
www.tropicalroofingproducts.com
FINISH COAT
APPLY A BEAD OF TROPICAL #950/951
MASTIC FOR ACRYLIC. OR, TROPICAL
#9100 MASTIC FOR SILICONE, OR SEALANT
TROPICAL #950/951 MASTIC FOR ACRYLIC
OR, TROPICAL #9100 MASTIC FOR SILICONE.
6” OR 12” FABRIC FULLY EMBEDDED IN
TROPICAL #950/951 MASTIC FOR ACRYLIC OR,
TROPICAL #9100 MASTIC FOR SILICONE.
COUNTER FLASHING
STANDARD MOD-BIT, BUR, AND
SINGLE-PLY DETAIL
23DETAIL NO :
DATE :
WALL TERMINATION DETAIL
FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
2"M
IN2"
6"
NOTES:
1. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE
SPECIFICATIONS AT www.tropicalroofingproducts.com
FINISH COAT. COLOR
AS SPECIFIED.
BASE COAT.
TROPICAL #950/951 MASTIC
FOR ACRYLIC. OR, TROPICAL
#9100 MASTIC FOR SILICONE.
6” OR 12” FABRIC FULLY
EMBEDDED IN TROPICAL
#950/951 MASTIC FOR
ACRYLIC OR, TROPICAL
#9100 MASTIC FOR SILICONE.
METAL ROOF PANEL
BACKING
25DETAIL NO :
DATE :
CONCRETE WALL TRANSITION DETAIL
FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
2"2"
MIN6"
NOTES:
1. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE
SPECIFICATIONS AT www.tropicalroofingproducts.com
FINISH COAT. COLOR AS
SPECIFIED.
BASE COAT.
TROPICAL #950/951 MASTIC FOR
ACRYLIC. OR, TROPICAL #9100
MASTIC FOR SILICONE.
6” OR 12” FABRIC FULLY EMBEDDED
IN TROPICAL #950/951 MASTIC FOR
ACRYLIC OR, TROPICAL #9100
MASTIC FOR SILICONE.
METAL ROOF PANEL
BACKING
26DETAIL NO :
DATE :
METAL WALL TERMINATION DETAIL
FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
metal roof panel
6"
NOTES:
1. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE
SPECIFICATIONS AT www.tropicalroofingproducts.com
TROPICAL #950/951 MASTIC FOR
ACRYLIC. OR, TROPICAL #9100
MASTIC FOR SILICONE FOR
EXPOSED FASTENERS.
FINISH COAT. COLOR
AS SPECIFIED.
BASE COAT.
TROPICAL #950/951 MASTIC
FOR ACRYLIC. OR, TROPICAL
#9100 MASTIC FOR SILICONE.
SKYLIGHT PANEL. PLEASE
REFER TO THE SKYLIGHT
MANUFACTURER
INSTALLATION DETAILS.
6” FABRIC FULLY EMBEDDED IN
TROPICAL #950/951 MASTIC FOR
ACRYLIC OR, TROPICAL #9100
MASTIC FOR SILICONE AROUND
SKYLIGHT PERIMETER.
TROPICAL #950/951 MASTIC FOR ACRYLIC OR,
TROPICAL #9100 MASTIC FOR SILICONE
27DETAIL NO :
DATE :
FLUSH SKYLIGHT DETAIL
FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
metal roof panel
metal cricket
2"min
skylight
NOTES:
1. NEW CRICKETS SHALL BE SEALED BY PLACING A BEAD OF TROPICAL #950/951 MASTIC FOR ACRYLIC
OR, TROPICAL # 9100 MASTIC FOR SILICONE UNDER THE FLANGES BEFORE THEY ARE MECHANICALLY
ATTACHED
2. Vertical SEAMS TO BE CUT BACK A MINIMUM OF 2” FROM CRICKET
3. RIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM
GUIDE SPECIFICATIONS AT www.tropicalroofingproducts.com
TROPICAL #950/951
MASTIC FOR ACRYLIC.
OR, TROPICAL #9100
MASTIC FOR SILICONE
FINISH COAT. COLOR
AS SPECIFIED.
BASE COAT.
TROPICAL #950/951 MASTIC
FOR ACRYLIC. OR, TROPICAL
#9100 MASTIC FOR SILICONE
6” FABRIC FULLY EMBEDDED IN
TROPICAL #950/951 MASTIC FOR
ACRYLIC OR, TROPICAL #9100
MASTIC FOR SILICONE AROUND
SKYLIGHT PERIMETER.
28DETAIL NO :
DATE :
SKYLIGHT CURB DETAIL
FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
NOTES: vent pipes/ducts may
require crickets depending on
their size and location (crickets
not shown).
metal roof panel
4"
4"
NOTES:
1 PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE
SPECIFICATIONS AT www.tropicalroofingproducts.com
FINISH COAT. COLOR AS SPECIFIED.
BASE COAT.
6” FABRIC FULLY EMBEDDED IN
TROPICAL #950/951 MASTIC FOR
ACRYLIC OR, TROPICAL #9100
MASTIC FOR SILICONE
TROPICAL #950/951 MASTIC FOR
ACRYLIC OR, TROPICAL #9100
MASTIC FOR SILICONE
29DETAIL NO :
DATE :
DUCT FLASHING DETAIL12-13-16FLUID APPLIED RESTORATION COATING SYSTEM
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
NOTES:
1. ALL FLASHING SHALL BE DESIGNED FOR APPLICABLE CONDITIONS. METAL THICKNESS, FASTENERS,
AND LAPPING SHALL BE AS SPECIFIED BY THE ROOF DESIGNER.
2. REFER TO THE SPECIFICATIONS FOR SPECIFIC EXECUTION REQUIREMENTS
3. FLUID APPLIED RESTORATION COATING SYSTEM – BASE COAT, REINFORCED FABRIC, BASE
COAT 2, AND FINISH COAT COMPONENTS.
4. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING
REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED
SYSTEM GUIDE SPECIFICATIONS AT www.tropicalroofingproducts.com
TAKE ENTIRE SYSTEM OVER TOP OF
PARAPET
TOP COAT COMPONENT OVER ENTIRE ROOF. COLOR AS
SPECIFIED.
FINISH COAT COMPONENT OVER ENTIRE ROOF. COLOR AS SPECIFIED
PARAPET WALL
TAKE 12” WIDE FINISH COAT, FABRIC, AND BASE COAT COMPONENTS
UP CANT AND TERMINATE VERTICALLY ON PARAPET
ROOF DECK AND INSULATION SYSTEM
WITH OR WITHOUT CANT STRIPS
OPTIONAL METAL COPING ASSEMBLY
FINISH COAT, FABRIC, AND FINISH COAT COMPONENTS
30DETAIL NO :
DATE :
WALL FLASHING DETAIL12-13-16
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
FLUID APPLIED RESTORATION COATING SYSTEM
6 "
min
.
1/4" MINUMUM SLOPE
6"
min
.
NOTES:
1. ALL FLASHING SHALL BE DESIGNED
FOR APPLICABLE CONDITIONS. METAL
THICKNESS, FASTENERS, AND LAPPING
SHALL BE AS SPECIFIED BY THE ROOF
DESIGNER.
2. REFER TO THE SPECIFICATIONS FOR
SPECIFIC EXECUTION REQUIREMENTS
3. FLUID APPLIED RESTORATION COATING
SYSTEM – BASE COAT, REINFORCED
FABRIC, BASE COAT 2, AND FINISH
COAT COMPONENTS.
4. PRIMING – REFER TO TROPICAL
ROOFING PRODUCTS SPECIFICATIONS
FOR DECK PRIMING REQUIREMENTS.
NOTE: FOR SPECIFIC PRODUCT
RECOMMENDATION REFER TO THE
APPROPRIATE FLUID APPLIED SYSTEM
GUIDE SPECIFICATIONS AT
www.tropicalroofingproducts.com
section
elevation
WALL OF FLUTED CMU
TAKE BASE COAT, 12” WIDE FABRIC, AND
BASE COAT COMPONENTS AND
TERMINATE 6” MIN. VERTICALLY ON WALL.
FLUID APPLIED RESTORATION COATING
SYSTEM – BASE COAT, REINFORCED
FABRIC, BASE COAT 2, AND FINISH COAT.
WALL OF FLUTED CMU
TAKE BASE
COAT, REINFORCING
FABRIC, AND BASE COAT
COMPONENTS AND
TERMINATE 6” MINIMUM
VERTICALLY ON WALL.
SLOPED
METAL ROOF
31DETAIL NO :
DATE :
ROOF TO WALL DETAIL12-13-16
disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.
FLUID APPLIED RESTORATION COATING SYSTEM