INTRODUCTION BERMUDA FILTERFORCE XTREME Filter & Waterfall Pumps are manufactured to the very highest standard of production quality. The pumps are carefully inspected and tested to ensure both maximum safety and operating performance. As with all electrical goods, it is critical that the full operating instruction manual is read and followed. Failure to do this may result in pump damage and/or personal injury. Be sure to read and save this manual for future reference. The FILTEFORCE EXTREME pump range is specifically designed for use in garden ponds to power biological filters, UV clarifiers and to run waterfalls. DO NOT USE in swimming pools. Young children should always be supervised near water. INFORMATION This is a submersible pump and therefore should NEVER be run out of water. The pump has a built in thermal overload protection device which prevents it from overheating. INSTALLATION You must always consult a qualified electrician or local electricity authority if you have any doubts about wiring to the mains electricity supply. This product is designed to be permanently wired to a mains supply through a RESIDUAL CIRCUIT DEVICE (RCD 30Ma) WARNING: This appliance must be earthed and it is essential that all connections are securely made using the following code: The wire which is coloured green-and-yellow must be connected to the terminal which is marked with the letter E or by the earth symbol or coloured green or green-and-yellow. The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black. The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. WARNING: SAFETY & ELECTRICAL CONNECTIONS The supply cable on this pump cannot be replaced. If the cable or motor housing is damaged, the pump should be discarded. The installation must conform to the regulations of the local electrical authority. If an extension cable is required, this should be connected to the end of the pump cable using a weatherproof cable connector. The joint must be positioned outside the water in a suitable dry housing. Always disconnect all appliances from the electrical supply before putting your hands in the water whilst the equipment is being installed, repaired, maintained or handled. * Do not use the supply cable to lift the pump as this may cause damage. We recommend fitting a lifting cord. * Do not operate or leave the pump in freezing conditions. * Do not allow the pump to run dry. * Check that the voltage marked on the pump corresponds to the mains supply. * Do not pump flammable liquids. * Operate in fresh water only. * Only operate the pump when fully submerged. OVERLOAD PROTECTION The pump has a built in thermal overload trip which prevents the pump from overheating. The pump must be allowed to cool down before restarting. If the pump will not start again automatically when cooled down, please check the following conditions: * Check the circuit breaker to ensure the pump is getting electrical power. * Is there sufficient water? * Has the filter become clogged? * Has dirt entered the pump housing? * Have hoses or jets become clogged? * Has the pump cooled down sufficiently? As soon as you have completed the checklist, you can start the pump again by reconnecting to the electricity supply. FILTERFORCE XTREME POWER FILTER & WATERFALL PUMPS 15000, 20000, 25000 & 30000 LITRES CODE: BER0621, BER0622, BER0623, BER0624 N L E IMPORTANT The wires in the mains lead are coloured in accordance with the following code: Green-and-yellow: Earth (E) Blue: Neutral (N) Brown: Live (L)

FILTERFORCE XTREME POWER FILTER & WATERFALL PUMPS · FILTERFORCE XTREME POWER FILTER & WATERFALL PUMPS 15000, 20000, 25000 & 30000 LITRES CODE: ... 2 Remove the front …

Embed Size (px)

Citation preview

Page 1: FILTERFORCE XTREME POWER FILTER & WATERFALL PUMPS · FILTERFORCE XTREME POWER FILTER & WATERFALL PUMPS 15000, 20000, 25000 & 30000 LITRES CODE: ... 2 Remove the front …

INTRODUCTIONBERMUDA FILTERFORCE XTREME Filter & Waterfall Pumps are manufactured to the very highest standard of production quality.

The pumps are carefully inspected and tested to ensure both maximum safety and operating performance.

As with all electrical goods, it is critical that the full operating instruction manual is read and followed. Failure to do

this may result in pump damage and/or personal injury.

Be sure to read and save this manual for future reference.

The FILTEFORCE EXTREME pump range is specifically designed for use in garden ponds to power biological filters, UV clarifiers

and to run waterfalls. DO NOT USE in swimming pools.

Young children should always be supervised near water.

INFORMATIONThis is a submersible pump and therefore should NEVER be run out of water. The pump has a built in thermal overload

protection device which prevents it from overheating.

INSTALLATIONYou must always consult a qualified electrician or local electricity authority if you have any doubts about

wiring to the mains electricity supply.

This product is designed to be permanently wired to a mains supply through a RESIDUAL CIRCUIT DEVICE (RCD 30Ma)

WARNING: This appliance must be earthed and it is essential that all connections are securely made using the

following code:

The wire which is coloured green-and-yellow must be connected to the terminal which is marked with the letter E or by the

earth symbol or coloured green or green-and-yellow.

The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.

The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.

WARNING: SAFETY & ELECTRICAL CONNECTIONSThe supply cable on this pump cannot be replaced. If the cable or motor housing is damaged, the pump should be discarded.

The installation must conform to the regulations of the local electrical authority.

If an extension cable is required, this should be connected to the end of the pump cable using a weatherproof cable connector.

The joint must be positioned outside the water in a suitable dry housing.

Always disconnect all appliances from the electrical supply before putting your hands in the water whilst the

equipment is being installed, repaired, maintained or handled.

* Do not use the supply cable to lift the pump as this may cause damage. We recommend fitting a lifting cord.

* Do not operate or leave the pump in freezing conditions.

* Do not allow the pump to run dry.

* Check that the voltage marked on the pump corresponds to the mains supply.

* Do not pump flammable liquids.

* Operate in fresh water only.

* Only operate the pump when fully submerged.

OVERLOAD PROTECTIONThe pump has a built in thermal overload trip which prevents the pump from overheating. The pump must be allowed to cool

down before restarting.

If the pump will not start again automatically when cooled down, please check the following conditions:

* Check the circuit breaker to ensure the pump is getting electrical power.

* Is there sufficient water?

* Has the filter become clogged?

* Has dirt entered the pump housing?

* Have hoses or jets become clogged?

* Has the pump cooled down sufficiently?

As soon as you have completed the checklist, you can start the pump again by reconnecting to the electricity supply.

FILTERFORCE XTREME POWER

FILTER & WATERFALL PUMPS 15000, 20000, 25000 & 30000 LITRES

CODE: BER0621, BER0622, BER0623, BER0624

N L

E IMPORTANT The wires in the mains lead are coloured in accordance with the following code: Green-and-yellow: Earth (E) Blue: Neutral (N) Brown: Live (L)

Page 2: FILTERFORCE XTREME POWER FILTER & WATERFALL PUMPS · FILTERFORCE XTREME POWER FILTER & WATERFALL PUMPS 15000, 20000, 25000 & 30000 LITRES CODE: ... 2 Remove the front …

MAINTENANCEMonthly maintenance will improve the performance of your pump and add to its life.

Follow the safety measures and disconnect from the electricity supply before attempting any maintenance.

1 Remove the front strainer cage by gently squeezing the sides and pulling forward, as per the above diagram.

2 Remove the front of the pump housing by unscrewing the 4 visible screws, as per the above diagram.

3 Pull the front of the housing away to expose the rotor impellor assembly, as per the above diagram

4 Remove the rotor impellor and clean it with fresh water to remove any weed or debris.

5 Ensure that the rubber 0 ring on the housing is sound and in good condition.

6 Refit the O ring.

7 Refit the rotor impellor making sure that it locks down completely by ensuring that the two lugs on the pump

body are matched with the two holes on the impellor plate and that the base of the shaft is fitted into the

bottom bearing sited in the pump body.

8 Refit the front housing to the pump body with the 4 screws provided.

9 Replace the front strainer.

TECHNICAL INFORMATION

Model Rated

voltage

Rated

power

input

Flow Max. Total

head

Max.

operation

depth

15000 220-240V 290W 15000 L/H 6.5M 2M

20000 220-240V 420W 20000 L/H 7.5M 2M

25000 220-240V 520W 25000 L/H 8M 2M

30000 220-240V 660W 30000 L/H 8.5M 2M

LIMITED WARRANTYThe product is guaranteed for a period of 3 years from the date of purchase for material and manufacturing defects.

The impellor and shaft are guaranteed for a period of 1 year from the date of purchase for material and manufacturing defects.

The guarantee covers the substitution of defective parts. However, the guarantee is considered void in the case of improper

use, improper handling or negligence on the part of the buyer. If your pump fails please return it to the retail outlet where

you purchased the product. Please note, you must take your proof of purchase with you.

This symbol means the product must not be discarded with your general household waste.

Local authorities provide designated disposal centres for electrical items. Please

locate your local centre and return the product there.

EXCLUSIVELY DISTRIBUTED BY:Solus Garden & Leisure Limited

Berry Hill Industrial Estate

Droitwich

Worcestershire WR9 9AB

Tel: 01905 798666 Find us on Facebook @ Bermuda Water Gardening