Film and Dropwise Exp

Embed Size (px)

Citation preview

  • 8/10/2019 Film and Dropwise Exp

    1/2

    1. Abstract

    The two main function of the film and drop wise condensation unit is to observe the

    process of heat transfer during condensation process and to collect experimental data for

    better theoretical understanding system. We are able to see bench top unit with an

    integrated steam generator and air extraction in the unit. Furthermore, the special about

    this unit is the main component are specifically designed condenser for the observation of

    both filmwise and dropwise condensation about the differences of them. The aims that we

    want to achieve are to study the heat transfer coefficient and the heat flux and the effect

    of air inside the chamber. Condensation is the process when vapour changes to liquid

    state with large heat transfer coefficient. On the other hand, film wise condensation

    occurs on a vertical or horizontal plane when a film of condensate is formed on surface.

    By using Nusselt equation, the heat transfer coefficient is able to be calculated. Nusselt

    assumed that the heat transfer that occurs from the vapour through film and to the wall is

    conduction. From there we are able to do the calculation on the heat transfer coeeficient

    since we assume the process is conduction through Nusselt.the obtained data from this

    experiment are Tsat, Tsurf, Tinand Tout.

    (Film and drop wise condensation unit,Solution Engineering Sdn Bhd )

    2. Introduction

    In condensation process there are two kinds, which are filmwise and dropwise. In

    filmwise condensation, a laminar film of vapour is created upon a surface. Then, the film

    flow downwards and increasing in thickness as additional vapour is picked up along the

    way. Meanwhile in dropwise it flow downwards and accumulating static droplets below

    them along the way. Furthermore, Dropwise condensation occurs when the rate of

    condensation is low or the liquid does not wet the wall. Additional, film condensation is

    most expected in an industrial part because of the large mass flux condensed liquid per

    unit length of wetted area.

    As additional information, dropwise condensation was first recognized by Schmidth

    et al in 1930and much interest was inspired by their report that heat transfer coefficient

    were 5 and 7 times found with film condensation. The application of this experiment in

    any industry is to increase the heat efficiency of heat transfer. For example, vapour power

  • 8/10/2019 Film and Dropwise Exp

    2/2