TAB1 : Frame Rating 20A to 160A
TAB2 : Frame Rating 63A to 250A
TAB3 : Frame Rating 250A to 630A
TAB : Thermal Adjustable Breaker
1/21, Asaf Ali Road, New Delhi - 110002 Ph.: 23234411, 23234811Fax : 011-23232639 e-mail:[email protected]
www.hplindia.com
The Power of Technology
Branch Offices:
BANGALORE
No.2D, II Floor, Farah Winsford133, Infantry Road, Bangalore - 560 001Ph.: 080-22863068Telefax : 080-22863069
E-mail: [email protected]
AHMEDABAD
B-707, 7th Floor, Premium House,B/H, Natraj Cinema, Ashram RoadAhmedabad - 380009Ph.: 079 - 30021901Telefax: 079 - 30021025E-mail: [email protected]
CHANDIGARH
S.C.O. 54, 2nd Floor, Sector - 26,Madhya Marg, Chandigarh - 160019Telefax.: 0172-5077815, 5049425E Mail : chandigarh@hplindia .com
CHENNAI
"Amar Sindur" S-4, 2nd Floor,No.-43, Pantheon Road, Egmore,Chennai-600008Ph.: 044-28551530Fax : 044-28551537E-mail: [email protected]
COCHIN
1st Floor, A.K.S. Mahal, XL/7813J,Achutha Warrier Lane, M.G.Road,Ernakulam, Cochin - 682 035Telefax : 0484-2354595E-mail: [email protected]
BHUBANESWAR
N3-135, IRC Village, Nayapali,Bhubaneswar-751012Ph.: 0674-6538229Telefax : 0674-2550826E-mail: [email protected]
DEHRADUN
EBD Business Centre, 13D49, Raipur Road, Dehradun (Uttrakhand)Ph.: 0135-2650340, 2650373E-mail: [email protected]
HYDERABAD
No.7-1-58, flat No.403, 4th Floor,Concourse Building, GreenLands Road, Hyderabad - 500 016Ph.: 040-66687878 / 66773117Telefax: 040-23740567
E-mail: [email protected]
INDORE
203, RNT Marg,Near Ravindra Natya Grah,Indore- 452001 Ph.: 0731-4225540E-mail: [email protected]
Millinda Manor 2
JAIPUR
205, Adarsh Plaza, Khasa KothiCircle Bani Park, Jaipur - 302001Ph.: 0141-5106268 / 4021035E-Mail: [email protected]
KANPUR
17/14, 2nd Floor, The Mall,Kanpur - 208 001 (U.P.)Ph.: 0512-2316017 Telefax: 0512-2353743E-mail: [email protected]
KOLKATA69, Ganesh Chandra Avenue, India House7th Floor, Block-C, Kolkata - 700013Ph.: 033-65394379 Telefax: 033-22252716E-Mail: [email protected]
LUCKNOW
Next Cabin of Advocate Mr. Vivek Saxena1st Floor, saran Chambers-II, 5 Park Road,Lucknow - 226001, Ph.: 0522-4021687E-Mail: [email protected]
MUMBAI2H, Rushabh Chambers 2nd Floor,Off-Makwana Road, Marol, Andheri (E)Mumbai - 400059Ph.: 022-30965176, 28506246, 28507112Telefax: 022-28528181E-mail: [email protected]
NAGPUR
Fortune Business Center,6, Vasant Vihar, W.H.C. Road,Shankar Nagar, Nagpur - 440010Ph.: 0712-2564880, 5611371
Fax : 0712-2550070E-mail: [email protected]
PUNE
1, Sai Complex, 3rd Floor, 917/22,Fergussan, College Road,Shivaji Nagar, Pune - 411 005Telefax: 020 - 25672928E-mail: [email protected]
RAIPUR
1st Floor, Near Holy Heart SchoolChattisgarh College Road,Civil Line, Raipur (C.G.) - 492006Ph.: 0771-4032001/6541590E-mail : [email protected]
RANCHI
203, Mahalaxmi Complex,Near Bargain Bazar, Line Tank Road,Ranchi - 834001 Ph.: 0651-2206144E-mail : [email protected]
VADODARA
409/410, Silver Oak Complex,
Near Shreenik, Park Char Rasta,Productivity Road, Akota,Vadodara - 390020 GujaratPh.: 0265 - 2341747 Fax : 2352107E-mail : [email protected]
VIJAYAWADA
D.No.-29-37-135, 2nd Floor,G. R. Plaza, Beside Canara Bank,Eluru Road, Vijayawada-520 002Ph.: 0866- 2442275, 6622291E-mail : [email protected]
VIZAG
B.K. Towers, 49-34-1/63,Akkayyapalem Main Road,NH-5 Junction, Vizag-530 016 (A.P.)Ph.: 0891-2794506, 6461730E-mail : [email protected]
GUWAHATI
Baraco Commerical Complex,G.S. Road, Ulubari,Guwahati - 781 007 Ph.: 0361-2450889E-mail: [email protected]
COIMBATORE
Designer Complex,Door No.130, C/2, 2nd Floor,Dr. Nanjappa Road,Coimbatore - 641018Ph.:0422-4393995E-mail : [email protected]
LUDHIANA
5 - A , First Fl oor, Roshan MarketVishwakarma Chowk, LudhianaE-Mail : [email protected]
AgartalaAgra
Allahabad
Anantpuram
Aurangabad
Bareilly
Belgaum
Bhopal
BhubaneshwarBijapur
Calicut
Davangere
Goa
Gorakhpur
Gulbarga
Hubli
JabalpurJabli
Jammu
Jamshedpur
Jalandhar
Jodhpur
Kanyakumari
Kolhapur
KotaMadurai
Malda
Mangalore
Meerut
Moradabad
Nagerkoil
Nasik
MysorePatiala
Patna
Pondicherry
Salem
Siliguri
Silchar
Solapur
SuratTirupati
Trichy
Trivandrum
Udaipur
Vapi
Varanasi
Resident Offices:
25
40
TAB250C
230; Uimp = 8kV
16
25
16
25
TAB160D
230; Uimp=8kV
your electrical protection
S itch on
8/6/2019 File 332
2/8
16
25
16
25
TAB160D
230;U imp = 8kV
Salient Features
?Conforms to IEC 60947-2 / IS 13947-2?Available in various frame sizes rated current from
20A-630A
?Wide range of breaking capacity available from10kA to 65kA
?Quick-make, Quick-Break & Trip Free mechanism.
?Clear indication of 'ON', 'OFF' and 'TRIP' position.
?Low let-through energy.
?Adjustable Thermal release (80-100%) offersclose protection from changing load.
?Line load reversibility available
?ROHS Compliant.
?Wide range of internal and external accessories.
?Uniform Door cut-out in line with MCB uptoSize TAB 2
?Uniform depth of MCCB upto Size TAB 2
2 3
CONTENTS
Salient features
Advantages
Technology
Working principle
Accessories
Characteristic curves
3
4
4
5
6
7
8
9
10
13
Application
Overview
Specifications
Product References & Ordering
The TAB Series
The TAB Series
8/6/2019 File 332
3/8
Applications
Distribution feeder protection
Transformer protection
DG set protection
Motor protection
Capacitor protection
Protection for semi-conductor
fuses
UPS protection
DC load protection
Suited for incoming and
outgoing feeders
Effective protection to
distribution transformers as
outgoing breakers.
Used for protection and control
of diesel generating sets against
overloads and short circuits.
MCCB provides motor back up
protection, provide type -2 co-
ordination (as per IEC 60947) in
conjunction with suitably rated
contactors and relays.
Used to protect capacitors.
Used to protect semiconductor
fuses.
Used for UPS and electronic
equipment protection.
Suitable for both AC as well as
DC application for protecting
rectifier panel.
MCCB is suitable for circuit protection in individual enclosures,switch board, lighting and power panels as well as motor controlcenters.
MCCB is assigned to protect systems against overload and shortcircuit up to 65KA with full range of accessories.
TMTAB ........series provides the following applications :-
Icu = O-CO
Ics = O-CO-CO
The rise in temperature on the terminals, body etc. after the S.C.breaking capacity test is well within limits to give better life to theproduct and also safeguards the entire distribution system.
Insulation
Operating Knob/Dolly is made of Thermoplastic insulating materialto make it safer & reliable.
Utilization Category
Utilization category for a circuit breaker shall be stated withreference to whether or not it is specifically intended for selectivityby means of an intentional time delay (with respect to other circuitbreaker in series). Utilization category is a regulation on application
with respect to selectivity.
1. Utilization Category A :
Circuit breaker not specifically intended for selectivity under shortcircuit conditions. Such breakers do not have a short time withstandcurrent rating. All Thermal-Magnetic breakers satisfy utilizationcategory A.
2. Utilization Category B" :
Circuit breaker specifically intended for selectivity under shortcircuit conditions. Such breakers have a short time withstandcurrent rating. All electronictype breakers satisfy utilizationcategory B.
Working PrincipleTM
TAB .....Series breakers work on current limiting principle.
Current limiting capacity of a circuit breaker is its aptitude to limitshort-circuit current. When a short circuit occurs, the breaker is able
2to limit and lower the I t energy release in very short time so as toprotect circuits and switchgear at downstream. This is achieved by
?Intelligent design of Arc Chamber
?Guiding the arc rapidly away from the contacts in the arcchamber.
?Quick opening of main contacts.
?Quick quenching of arc by using effective arc quenchingmethods & materials.
Therefore Ipk is limited to Ic which leads to substantial reduction in2
electrodynamic stresses in the system. Also I t let throughproportional to the shaded area is considerably reduced, resultingin lower thermal stresses in downstream equipment andconnecting cables.
Ipk
Ic
Advantages1. Compactness :
It is very compact in size and hence helps in savingspace in the enclosures, panels etc. Due to its slim sizeit uses the distribution space very efficiently regardlessof fact whether it is in residential or functionalbuildings.
2. Simplicity :
Its handling is easy and simple. Its simplicity and easein use allows the user for quick installation.
3. Safe to use :
It is very safe to use. It protects people, installation andpower supply distribution system. The insulationproperty of the material used is highly reliable andremains intact in even critical conditions.
Evolution
To reflect a variety of uses and applica tions, the line uphas been expanded up to 65 KA with highspecifications. As consumption of power isincreasing, circuit breaker demands for a new level offunctionality, flexibility, power and space saving hasbecome imminent.
TMHPL has got its very new TAB series of MCCBswhich has improved performance and safety.
It conforms to the latest IS & IEC standards.
Ics= 100%Icu
The IS/IEC 60947-2 specifies the Icu (rated ultimateshort circuit) and Ics (rated service short circuit)breaking capacities to the following types:-
4Thermal Adjustable Breaker 5Thermal Adjustable Breaker
Prospectivecurrent
Cut-off current
TAB630H
65
95 47.5
32.5
230;U imp= 8kV
16
25
16
25
TAB160D
230
25
40
18.75
30
TAB250C
230; Uimp=8kV
; Uimp= 8kV
The TAB Series
8/6/2019 File 332
4/8
Operating Conditions
1. Temperature : MCCBs are calibrated at 40C as reference ambientTemperature. However with increase in ambient, compensationfactor to be taken into consideration.
2. Altitude : It should be less than 2000m.
3. Pollution Degree : 3
Isolation Function
These MCCBs are suitable for isolation also. As defined in IEC 60947-2/IS 13947-2, the operation of isolation function highlights thefollowing points:-
Contacts operation correctly indicates operating reliability of interiormechanism.
No residual current.
Higher impulse withstand voltage for terminals at the power supplyside and load side.
Line-load Reversibility
MCCBs have no bias of lineload connec tion. The power supply can beconnected from either top or bottom which has no effect on normaloperation of the breaker.
The Technology For MCCB Devices
1. Arc Chamber
The MCCB arc chamber is specially designed with an arc channel as a
flow guide to improve the capability of extinguishing the arc andreducing the arc distance.
2. MCCB Base And Cover
Cover and Base moulding are made of superior quality ofThermoplastics to with stand the stringent short circuit conditionswith very high insulation strength to avoid any damage to theproduct. Covers are secured on Base mouldings with mountingscrews tightened into threaded inserts in the MCCB base to havebetter strength.
3. Fixed Contact
The MCCB fixed contact does not have any mounting screws near thecontact points. A steel screw can generate heat and the magnetic fluxsurrounding the conductor carrying the current can create a very hightemperature. If a short-circuit occurs, it will cause the contact points
to be welded or melted.
4. Thermal Magnetic Tripping
1. In case of Thermal overload, time-delay operation occurs when anover current heats and warps the bimetal to actuate the trip bar.(See-'A')
2. In case of Magnetic tripping, when high current passes through,the magnetization of the fix core enables it to attract the armaturefixed on trip bar thereby tripping the breaker. (See-'B')
1
2
3
4
B
A
Technology for MCCB Devices Overview
6Thermal Adjustable Breaker 7Thermal Adjustable Breaker
The TAB SeriesThe TAB Series
8/6/2019 File 332
5/8
It has a wide range of accessories giving convenience andadditional protection. They are of two types.
1. Internal accessory
2. External accessory.
Internal Accessories:Shunt Trip Coil
It is a release energized by a source of voltage which may beindependent of the voltage of the main circuit. It providesremote tripping of the circuit breaker. Once the MCCB trips it
prevents burning of coil even if supply is continuous to coil.Its operating voltage is 70% to 110 % of rated voltage.
Undervoltage Release
It permits a mechanical switching device to open or close,with or without time delay, when voltage across release fallsbelow a predetermind value. The normal working range is35- 70% of the rated voltage.
Auxillary Switch
It is used for remote signaling and control purposes. Itconsists of one or more than one potential free change overcontact and acts as an indicator whether the circuit breaker'sstatus is open or closed.
Alarm Switch
It is an auxiliary switch which operates only upon the trippingof the circuit breaker. It gives tripping indication once theMCCB trips.
External Accessories:Rotary Handle
It is a toggle handle operating mechanism which serves asswitching position indicator ON, OFF, TRIP. Basically it is usedwith breaker which is installed in an enclosure that does not
allow ready access to the breaker's operating handle. Thehandle is allowed to be locked in the OFF or ON position forsafety. This feature helps to reduce the risk associated witharc related flash burns.
Phase Barrier
Phase barriers are provided between the phases to increasethe creepage distance between them thereby reducing therisk of phase to phase shorting.
Technical Features
1. Standard conformity : IEC-60947-2&IS -13947-2
2. Rated operational voltage : 415V AC
3. Rated insulation voltage: 690V AC
4. Utilization category : A
5. Rated frequency: 50/60Hz.
6. Rated impulse voltage : 8kV
Accessories Product Reference & Ordering
Frame Breaking Ics = Rated Current Rated Current Rated Current Current No. of
size Capacity % Icu TAB 160 TAB 250 TAB 630 Main Poles
TAB 160 L : 10 kA X = 100% 020 063 250 AC 2P
TAB 250 D : 16 kA Y = 75% 025 080 320 DC 3P
TAB 630 C : 25 kA Z = 50% 032 100 400 4P
N : 36 kA 040 125 500
S : 50 kA 050 160 630
H : 65 kA 063 200080 250
100
125
160
Accessories for TAB MCCB
Frame Shunt Under Voltage Auxiliary Alarm Rotary
size Release Release Switch Switch Handle
TAB 160 110 VAC 110 VAC 1 C/O 1 C/O RHDM : Door Mounted
TAB 250 240 VAC 240 VAC 2 C/O RHCM : Breaker
TAB 630 415 VAC 415 VAC Mounted
024 VDC 024 VDC
048 VDC 048 VDC?Product Reference for 240 VAC shunt release with TAB 160 is TAB160SHT240VAC
?Product Reference for 240 VAC under voltage release with TAB 160 is TAB160UVR240VAC
?Product Reference for 1 C/O Auxiliary switch with TAB 160 is TAB160AXC1
?Product Reference for 1 C/O Alarm Switch with TAB160 is TAB160ALC1
?Product Reference for 1 C/O Alarm / Auxiliary Switch with TAB160 is TAB16 ISI TAB160 ALAX
?Product Reference for Rotary Handle Door Mounted with TAB 160 ISI TAB 160 RHDM
?A Maximum 2 Nos. Internal Accessories can be selected for one Breaker, one on e ach side
?Shunt or Under voltage release is fitted on LHS.
?Auxiliary / Alarm Switch is fitted on RHS.
8Thermal Adjustable Breaker 9Thermal Adjustable Breaker
TAB 160
?TAB 160 MCCB is available with breaking capacity 10 kA / 16 kA / 25 kA / 36 kA
?TAB 250 MCCB is available with breaking capacity 25 kA / 36 kA / 50 kA
?TAB 630 MCCB is available with breaking capacity 36 kA / 50 kA / 65 kA
?TAB 160 MCCB is available ready stock in different current ratings and breaking capacity
?TAB 250 & TAB 630 MCCBs will be available from 2010. Please contact our nearest sales office for more information.
L X 100 AC 3P
The TAB Series The TAB Series
8/6/2019 File 332
6/8
Frame 1
No. of poles 3/4
Type L D C N
Rated Current* 20-160A 20-160A 20-160A 20-160A
Rated Operational Voltage 415V
Rated Insulation Voltage 800V
Rated Impulse withstand voltage 8kV
Dielectric strength 3 KV for 1 minute
Rated Frequency 50/60 Hz
Reference Ambient Calibration Temperature** 40C
Rated Ultimate S.C. Breaking Capacity 10 16 25 36(at 415 VAC, 50/60 Hz) Icu in kA
Rated Ultimate S.C. Breaking Capacity 16 25 40 50(at 230 VAC, 50/60 Hz) Icu in kA
Rated Ultimate S.C. Breaking Capacity 12 18 30 40(at 250 VDC) Icu in kA
Rated Service S.C. Breaking Capacity 100% Icu 100% Icu 75% Icu 50% Icu(at 415 VAC, 50/60 Hz) Ics in kA
Rated Service S.C. Breaking Capacity 100% Icu 100% Icu 75% Icu 50% Icu(at 230 VAC, 50/60 Hz) Ics in kA
Rated S.C. Making Capacity 17 32 52.5 75.6
(at 415 VAC, 50/60 Hz) Icm in kA
Utilization Category A
Positive Isolation Available
No. of operating cycles Mechanical-25000; Electrical-7000
Type of Releases Thermal - MagneticRelease Setting Thermal 80-100% Adjustable
Release Setting Magnetic Fixed2
Terminal Capacity (Cables) 50mm max.2
Terminal Capacity (Link) 120mm max.
Terminal Capacity (Busbar width for direct mounting) 16 mm max.
Size (H x B x D) Dim. 3P 4P UnitH 130 130 mmB 75 100 mmD 71 71 mm
Weight 0.9 Kg (3P) & 1.15 Kg (4P)
Reference Standards IEC 60947-2/IS 13947 (Part 2)
Notes :- *Continuous current rating available are 20, 25, 32, 40, 50, 63, 80, 100, 125 & 160 Amps.
**However on demand, MCCBs can be provided with calibration done at higher temperature also.
4P MCCBs are available in TPN as well as true 4 pole version.
Specifications
No. of poles 3/4
Type - C N S
Rated Current* _ 63-250A 63-250A 63-250A
Rated Operational Voltage 415V
Rated Insulation Voltage 800V
Rated Impulse withstand voltage 8kV
Dielectric strength 3 KV for 1 minute
Rated Frequency 50/60 Hz
Reference Ambient Calibration Temperature** 40C
Rated Ultimate S.C. Breaking Capacity - 25 36 50(at 415 VAC, 50/60 Hz) Icu in kA
Rated Ultimate S.C. Breaking Capacity - 40 50 70(at 230 VAC, 50/60 Hz) Icu in kA
Rated Ultimate S.C. Breaking Capacity - 30 40 55(at 250 VDC) Icu in kA
Rated Serv ice S.C. Breaking Capac ity - 75% Icu 50% Icu 50% Icu(at 415 VAC, 50/60 Hz) Ics in kA
Rated Serv ice S.C. Breaking Capac ity - 75% Icu 50% Icu 50% Icu(at 230 VAC, 50/60 Hz) Ics in kA
Rated S.C. Making Capacity - 52.5 75.6 105
(at 415 VAC, 50/60 Hz) Icm in kA
Utilization Category A
Positive Isolation Available
No. of operating cycles Mechanical-25000; Electrical-7000
Type of Releases Thermal-MagneticRelease Setting Thermal 80-100% Adjustable
Release Setting Magnetic Fixed2
Terminal Capacity (Cables) 95mm max.2
Terminal Capacity (Link) 185mm max.
Terminal Capacity (Busbar width for direct mounting) 22 mm max.
Size (H x B x D) Dim. 3P 4P UnitH 150 150 mmB 105 140 mmD 72 72 mm
Weight ...Kg (3P) & ........Kg (4P)
Reference Standards IEC 60947-2/IS 13947 (Part 2)
Notes :- *Continuous current rating available are 63, 80, 100, 125, 160, 200 & 250 Amps.
**However on demand, MCCBs can be provided with calibration done at higher temperature also.
4P MCCBs are available in TPN as well as true 4 pole version.
10Thermal Adjustable Breaker 11Thermal Adjustable Breaker
75
25
131
107
92
71
45
68
Frame 2
35.0
120.0
150.0
105
TEST
72
68
103
45.0
TEST
The TAB1 Series
Specifications The TAB2 Series
8/6/2019 File 332
7/8
Frame 3
No. of poles 3/4
Type - N S H
Rated Current* _ 250-630A 250-630A 250-630A
Rated Operational Voltage 415V
Rated Insulation Voltage 800V
Rated Impulse withstand voltage 8kV
Dielectric strength 3 KV for 1 minute
Rated Frequency 50/60 Hz
Reference Ambient Calibration Temperature** 40CRated Ultimate S.C. Breaking Capacity - 36 50 65(at 415 VAC, 50/60 Hz) Icu in kA
Rated Ultimate S.C. Breaking Capacity - 65 85 95(at 230 VAC, 50/60 Hz) Icu in kA
Rated Ultimate S.C. Breaking Capacity - 20 25 35(at 250 VDC) Icu in kA
Rated Serv ice S.C. Break ing Capaci ty - 75% Icu 50% Icu 50% Icu(at 415 VAC, 50/60 Hz) Ics in kA
Rated Serv ice S.C. Break ing Capaci ty - 75% Icu 50% Icu 50% Icu(at 230 VAC, 50/60 Hz) Ics in kA
Rated S.C. Making Capacity - 75.6 105 143
(at 415 VAC, 50/60 Hz) Icm in kA
Utilization Category A & B
Positive Isolation Available
No. of operating cycles Mechanical-20000; Electrical-4000
Type of Releases Thermal-Magnetic & Electronic
Release Setting Thermal Adjustable (80-100% in Thermal-Magnetic type);(50-100% in Electronic type)
Release Setting Magnetic Adjustable (60-120% in Thermal-Magnetic type);(30-120% in Electronic type)
Rated Short Time Withstand capacity 6(at 415 VAC, 50 Hz for 1 sec) Icw in kA***
Terminal Capacity (Cable) -2
Terminal Capacity (Link) 320mm max.
Terminal Capacity (Busbar width for direct mounting) 28 mm max.
Size (H x B x D) Dim. 3P 4P UnitH 254.5 254.5 mmB 140 184 mmD 99 99 mm
Weight ...Kg (3P) & ........Kg (4P)
Reference Standards IEC 60947-2/IS 13947 (Part 2)
Notes :- *Continuous current rating available are 250, 315, 400, 500 & 630 Amps.
**However on demand, MCCBs can be provided with calibration done at higher temperature also.***for category "B" Electronic MCCB only. 4P MCCBs are available in TPN as well as true 4 pole version.
0.01
0.1
1
10
100
1000
10000
1 min
2 min
5 min
10 min
20 min
30 min
1 Hr
2 Hr
x In (Current in Amps)
TripTime(Seconds)
ThermalCurrent
Rating (A)
25
32
40
50
63
80
100
125
160
Mag.Current
Setting (A)
500
500
500
500
900
900
1000
1250
1600
Ambient Compensation Curve(TAB-1)
0 %
50%
100%
200%
10
150%
250%
20 30 40 50 60 70 80
CURRE
NTIN%
TEMPERATURE IN 0C
0.01
0.1
1
10
100
1000
10000
1 min
2 min
5 min
10 min
20 min
30 min
1 Hr
2 Hr
x In (Current in Amps)
TripTime(Seconds)
T
hermalCurrent
Rating (A)
63
80
125160
200250
Mag.Current
Setting (A)
1000
125016002000
2500
Ambient Compensation Curve (TAB-2)
0 %
50%
100%
200%
10
150%
250%
20 30 40 50 60 70 80
CURRENTIN%
TEMPERATURE IN 0C
TMT-C Curve (TAB -2)
TMT-C Curve (TAB -1)
x In (Current in Amps)
80% 100%
20151052 8
TripTime(Seconds)
Milliseconds
Seconds
Min
utes
(612 ) x In
1
4
10
40
100
400
1
4
10
401
4
10
40
1002H
TMT-C Curve (TAB -3)
Ambient Compensation Curve (TAB-3)
0 %
50%
100%
200%
10
150%
250%
20 30 40 50 60 70 80
CURRENTIN%
TEMPERATURE IN 0C
Characteristic
12Thermal Adjustable Breaker 13Thermal Adjustable Breaker
1 2 3 4 5 6 7 8 9 10 20 30 40 5 0 60 70 8090100
1 2 3 4 5 6 7 8 9 10 20 30 40 5 0 60 70 8090100
254
215
630AON
OFF
44
140
137
99
108
97
ON
OFF
630A
20 500
500
100
1000
1000
Specifications The TAB3 Series The TAB Series
8/6/2019 File 332
8/8
Other HPL Industrial Products
14www.hplindia.com 15www.hplindia.com
Changeover Switch Automatic Transfer Switch
Switch Disconnector Fuse HRC Fuse Link
MCB / RCCB Energy Meters
TECHNO
C 40
I
O
240 /415V-100003