FIELD EXPEDIENT BLEEDING SIMULATION SYSTEM TM MANNEQUIN MODIFICATION KIT FS-1000ET SKEDCO INC. 1-800-770-SKED (7533) WWW.SKEDCO.COM Copyright 2008 by SKEDCO, Inc. All Rights Reserved Packing list 2 4” Joint Replacement Fittings 2 6” Joint Replacement Fittings 4 sets of Nasal Cannula 10 Blood Assemblies 6 Blood Coupler Bodies 1 3ft length of wire 1 mini hot glue gun 1 12 pk of mini hot glue sticks 1 Hand File 1 Drill Bit 1 Hand Saw SKEDCO INC. 1-800-770-SKED (7533) WWW.SKEDCO.COM Copyright 2008 by SKEDCO, Inc. All Rights Reserved

FIELD EXPEDIENT BLEEDING SIMULATION SYSTEM Modification Instru… · the Control Pack into the Mannequin chest cavity. Connect the tubing to the FEBSS™ Bladder Bag as needed. Insert

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FIELD EXPEDIENT BLEEDING SIMULATION SYSTEM Modification Instru… · the Control Pack into the Mannequin chest cavity. Connect the tubing to the FEBSS™ Bladder Bag as needed. Insert

FIELD EXPEDIENTBLEEDING SIMULATION SYSTEMTM

MANNEQUIN MODIFICATION KITFS-1000ET

SKEDCO INC.1-800-770-SKED (7533)

WWW.SKEDCO.COM

Copyright 2008 by SKEDCO, Inc. All Rights Reserved

Packing list

2 4” Joint Replacement Fittings2 6” Joint Replacement Fittings4 sets of Nasal Cannula 10 Blood Assemblies6 Blood Coupler Bodies1 3ft length of wire1 mini hot glue gun1 12 pk of mini hot glue sticks1 Hand File 1 Drill Bit 1 Hand Saw

SKEDCO INC.1-800-770-SKED (7533)

WWW.SKEDCO.COM

Copyright 2008 by SKEDCO, Inc. All Rights Reserved

Page 2: FIELD EXPEDIENT BLEEDING SIMULATION SYSTEM Modification Instru… · the Control Pack into the Mannequin chest cavity. Connect the tubing to the FEBSS™ Bladder Bag as needed. Insert

2 4” Joint Replacement Fittings2 6” Joint Replacement Fittings4 sets of Nasal Cannula 10 Blood Assemblies6 Blood Coupler Bodies1 12 pk of mini hot glue sticks

1 mini hot glue gun 1 3ft length of wire 1 Hand File 1 Drill Bit 1 Hand Saw

6. Continue from previous page.

7. Create 3-D mannequin wound from moulage fabrication kit.

8. Create mannequin wound from simulaid injury using nylon stocking.

Page 3: FIELD EXPEDIENT BLEEDING SIMULATION SYSTEM Modification Instru… · the Control Pack into the Mannequin chest cavity. Connect the tubing to the FEBSS™ Bladder Bag as needed. Insert

6. Continue from previous page. 1. Drill Tubing Holes— use the enclosed 9/16” drill bit to drill all tubing holes. Begin by enlarging mannequin torso joint connection holes.

2. Create joint connections and create tubing holes in the mannequin arms. Repeat the steps on the second mannequin arm.

Page 4: FIELD EXPEDIENT BLEEDING SIMULATION SYSTEM Modification Instru… · the Control Pack into the Mannequin chest cavity. Connect the tubing to the FEBSS™ Bladder Bag as needed. Insert

2. Continue from previous page. 6. Modify mannequin exchangeable pads to bleed.

Page 5: FIELD EXPEDIENT BLEEDING SIMULATION SYSTEM Modification Instru… · the Control Pack into the Mannequin chest cavity. Connect the tubing to the FEBSS™ Bladder Bag as needed. Insert

4. Create joint connections and create tubing holes in the abdominal and chest cavity to connect the mannequin legs.

5. Connect the FEBSS™ Control Pack to the FEBSS™ Bladder Bag and insert the Control Pack into the Mannequin chest cavity. Connect the tubing to the FEBSS™ Bladder Bag as needed. Insert the Bladder Bag into the mannequinchestcavityandfillwithsimulationblood.

3. Create joint connections and create tubing holes in the mannequin legs. Repeat the steps on the second mannequin leg.

Page 6: FIELD EXPEDIENT BLEEDING SIMULATION SYSTEM Modification Instru… · the Control Pack into the Mannequin chest cavity. Connect the tubing to the FEBSS™ Bladder Bag as needed. Insert

3. Continue from previous page. 3. Continue from previous page.