5
Page 1/1 12 V 60Ah (C 5 ) Light Traction Flooded Battery PHYSICAL CHARACTERISTICS SI Units US Units Length 278 mm 11 inch Width 175 mm 6.9 inch Height 190 mm 7.5 inch Typical weight 18.2 kg 40.12 lbs Specifications : Performance characteristics: BATTERY DISCHARGE PERFORMANCE AT 25 o C Discharge rate C 5 (5 h) C 20 (20 h) C 100 (100 h) Capacity at 25 A End of discharge voltage 10.20 V 10.50 V 10.80 V 10.50 V Discharge capacity 60 Ah 75 Ah 80 Ah 130 min / 54.1 Ah Temperature correction factor of discharge C 5 (5 h) capacity Temperature -10 o C 0 o C 20 o C 25 o C 30 o C 35 o C 40 o C Correction factor 0.76 0.82 0.94 0.97 1.00 1.03 1.06 BATTERY CHARGE CONDITIONS (according DIN 41773 and DIN 41774) Charging profiles: WaW0 and IUIa Charge factor: 1.10 1.20 . Nominal voltage: 12 V Rated capacity: 60 Ah (at C 5 and 30 o C) Plate technology: Antimony / Calcium Separator: Polyethylene + glass mat Electrolyte: Sulphuric acid; analytical grade Standards: IEC 60254; IEC 60095; IEC 61427 Issue 6 1 0 2 . 2 0 : e t a d Case / Lid material: Polypropylene Lid type: SMF Terminal type: Top / Automotive Carrying Handles: Available Cycles at 75% DoD: more than 400 PVES applications: more than 800 cycles PROXITECH S.A.S. 3 Avenue Gutenberg - 77600 Bussy-Saint-Georges - FRANCE - Tél. 01 71 58 26 10 - Fax. 01 71 58 26 15 - [email protected] - www.proxitech.com Fiche technique 55T WaW0-(double slope taper) characteristics for flooded batteries) Charging times with WaW0-characteristics in hours for PzS batteries at 30°C IUIa-characteristics for flooded batteries Charging times with IUIa-characteristics in hours for PzS batteries at 30°C

Fiche technique - Proxivolt · BATTERY CHARGE CONDITIONS (according DIN 41773 and DIN 41774) Charging profiles: WaW0 and IUIa Charge factor: 1.10 – 1.20. • Nominal voltage: 12

  • Upload
    others

  • View
    9

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Fiche technique - Proxivolt · BATTERY CHARGE CONDITIONS (according DIN 41773 and DIN 41774) Charging profiles: WaW0 and IUIa Charge factor: 1.10 – 1.20. • Nominal voltage: 12

Pag

e 1/

1

12 V 60Ah (C5) Light Traction Flooded BatteryPHYSICAL CHARACTERISTICS

SI Units US Units

Length 278 mm 11 inch

Width 175 mm 6.9 inch

Height 190 mm 7.5 inch

Typical weight 18.2 kg 40.12 lbs

Specifications:

Performance characteristics:BATTERY DISCHARGE PERFORMANCE AT 25oC

Discharge rate C5 (5 h) C20 (20 h) C100 (100 h) Capacity at 25 AEnd of discharge voltage 10.20 V 10.50 V 10.80 V 10.50 VDischarge capacity 60 Ah 75 Ah 80 Ah 130 min / 54.1 Ah

Temperature correction factor of discharge C5 (5 h) capacityTemperature -10 oC 0 oC 20 oC 25 oC 30 oC 35 oC 40 oCCorrection factor 0.76 0.82 0.94 0.97 1.00 1.03 1.06

BATTERY CHARGE CONDITIONS (according DIN 41773 and DIN 41774)Charging profiles: WaW0 and IUIa Charge factor: 1.10 – 1.20

.

• Nominal voltage: 12 V• Rated capacity: 60 Ah (at C5 and 30 oC)• Plate technology: Antimony / Calcium• Separator: Polyethylene + glass mat• Electrolyte: Sulphuric acid; analytical grade• Standards: IEC 60254; IEC 60095; IEC 61427

Issu

e6102.20 :etad

• Case / Lid material: Polypropylene • Lid type: SMF• Terminal type: Top / Automotive• Carrying Handles: Available• Cycles at 75% DoD: more than 400• PVES applications: more than 800 cycles

PROXITECH S.A.S. 3 Avenue Gutenberg - 77600 Bussy-Saint-Georges - FRANCE - Tél. 01 71 58 26 10 - Fax. 01 71 58 26 15 - [email protected] - www.proxitech.com

Fiche technique 55T

WaW0-(double slope taper) characteristics for �ooded batteries) Charging times with WaW0-characteristics in hours for PzS batteries at 30°C

IUIa-characteristics for �ooded batteries Charging times with IUIa-characteristics in hours for PzS batteries at 30°C

Page 2: Fiche technique - Proxivolt · BATTERY CHARGE CONDITIONS (according DIN 41773 and DIN 41774) Charging profiles: WaW0 and IUIa Charge factor: 1.10 – 1.20. • Nominal voltage: 12

DIMENSIONS

PERFORMANCE TECHNOLOGY

56

BATTERY 12V 90T

Width (mm): 175 Electrolyte (kg):

Theight (mm): 229 Total weight (Kg):

12

TECHNICAL DATASHEET 90T TDS

TAB ID:

7,4Length (mm): 303 Lead weight (kg): 20,0

28,7Height (mm): 208

Capacity C5 (Ah):* 90 Plate type (poz/neg): Tubolar/PastedVoltage (V): Type: Flooded

Cycles (70% DoD):* 1200 Separator: PECapacity C20 (Ah): 110 Grid alloy (poz/neg): Sb/Sb

CONTAINER COVER PLUGS HANDLES

* IEC / EN 60254-1 Electrolyte (g/cm3): 1,28

Type: 59518 Type: FlatColour: Black Colour: Black

Type: RopeColour: Black Colour: BlackType: M27

Hold down: B1 Polarity: 0Terminal: 1Filter: No

DRAWINGCNT Pc./pallet:

PACKAGING Type: EUR Pc./pallet: 42

208 22

9

303

175

174,

5

303

244,9

3 Avenue Gutenberg - 77600 Bussy-Saint-Georges - FRANCETél. 01 71 58 26 10 - Fax. 01 71 58 26 15 - [email protected] - www.proxitech.com

Page 3: Fiche technique - Proxivolt · BATTERY CHARGE CONDITIONS (according DIN 41773 and DIN 41774) Charging profiles: WaW0 and IUIa Charge factor: 1.10 – 1.20. • Nominal voltage: 12

D A T A S H E E T 95T

CHARGING INSTRUCTIONS

Charger Voltage Settings (at 77°F/25°C)

System Voltage 12V 24V 36V 48V

Bulk Charge 14.82 29.64 44.46 59.28

Float Charge 13.50 27.00 40.50 54.00

Equalize Charge 16.20 32.40 48.60 64.80

Do not install or charge batteries in a sealed or non-ventilated compartment. Constant under or overcharging will damage the battery and shorten its life as with any battery.

STATE OF CHARGE

Percentage Charge S Gravity Cell 12 Volt

100 1.277 2.122 12.73

90 1.258 2.103 12.62

80 1.238 2.083 12.50

70 1.217 2.062 12.37

60 1.195 2.040 12.24

50 1.172 2.017 12.10

40 1.148 1.993 11.96

30 1.124 1.969 11.81

20 1.098 1.943 11.66

10 1.073 1.918 11.51

OPERATIONAL DATA

Operating Temperature Self Discharge

-4°F to 113°F (-20°C to +45°C). At temperatures below 32°F (0°C) maintain a state of charge greater than 60%.

5 – 15% per month depending on storage temperature conditions.

CHARGING TEMPERATURE COMPENSATION

Add Subtract

0.005 volt per cell for every 1°C below 25°C0.0028 volt per cell for every 1°F below 77°F

0.005 volt per cell for every 1°C above 25°C 0.0028 volt per cell for every 1°F above 77°F

PRODUCT + PHYSICAL SPECIFICATIONS

BCI Group Size Type Voltage Cell(s) G C Weight Lbs. (kg)

Length Width Height F

27 95T 12 6 7, 8, 9, 16 12.84 (326) 6.60 (168) 9.74 (247) 55 (25)

MODEL 95T with POD ventVOLTAGE 12

MATERIAL Polypropylene

DIMENSIONS Inches (mm)

BATTERY Deep-Cycle Flooded/Wet Lead-Acid BatteryWATERING N/A

ELECTRICAL SPECIFICATIONS

Cranking Performance A Minutes B Amp-Hours (AH) Energy (kWh) Internal Resistance (mΩ) Short Circuit Current (amps)

C.C.A.D @ 0°F (-18°C) C.A.E @ 32°F (0°C) @ 25 Amps @ 75 Amps 5-Hr 10-Hr 20-Hr 100-Hr 100-Hr— —

— — 175 45 85 97 105 117 1.40

3 Avenue Gutenberg - 77600 Bussy-Saint-Georges - FRANCETél. 01 71 58 26 10 - Fax. 01 71 58 26 15 - [email protected] - www.proxitech.com

Page 4: Fiche technique - Proxivolt · BATTERY CHARGE CONDITIONS (according DIN 41773 and DIN 41774) Charging profiles: WaW0 and IUIa Charge factor: 1.10 – 1.20. • Nominal voltage: 12

TROJAN 27TMX PERFORMANCE PERCENT CAPACITY VS. TEMPERATURE

20%0% 40% 60% 80% 100% 120%

0

20

-20

-40

40

60

80

100

120

140

0

-20

-10

-30

-40

10

20

30

40

50

60

Tem

pera

ture

(C)

Percent of Available Capacity

Tem

pera

ture

(F)

1

10

100

1000

10 100 1000 10000 100000

Estimation Purposes Only

BATTERY DIMENSIONS (shown with WNT)

A. The number of minutes a battery can deliver when discharged at a constant rate at 80°F (27°C) and maintain a voltage above 1.75 V/cell. Capacities are based on peak performance.

B. The amount of amp-hours (AH) a battery can deliver when discharged at a constant rate at 80°F (27°C) and maintain a voltage above 1.75 V/cell. Capacities are based on peak performance.

C. Dimensions may vary depending on type of handle or terminal. Batteries should be mounted with 0.5 inches (12.7 mm) spacing minimum.

D. C.C.A. (Cold Cranking Amps) - the discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 0°F (-18°C) at a voltage above 1.2 V/cell.

E. C.A. (Cranking Amps) - the discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32°F (0°C) at a voltage above 1.2 V/cell. This is sometimes referred to as marine cranking amps @ 32°F or M.C.A. @ 32°F.

F. Height taken from bottom of the battery to the highest point on the battery. Heights may vary depending on type of terminal. G. Terminal images are representative only.

95T DS 2016_0907

TERMINAL CONFIGURATIONSG

Disch

arge

Curre

nt (a

mps

)

Time (mins)

16 SLT Small L-Terminal

Terminal Height Inches (mm) 1.31 (33)

Torque Values in-lb (Nm) 95 – 105 (11 – 12)

Bolt 5/16”

9 WNT Wingnut Terminal

Terminal Height Inches (mm) 1.50 (38)

Torque Values in-lb (Nm) 95 – 105 (11 – 12)

Bolt 5/16”

8 AP Automotive Post Terminal

Terminal Height Inches (mm) 0.83 (21)

Torque Values In-lb (Nm) 50 – 70 (6 – 8)

7 UT Universal Terminal

Terminal Height Inches (mm) 1.10 (28)

Torque Values in-lb (Nm) 95 – 105 (11 – 12)

Bolt 5/16”

9.74 (247)HEIGHT

6.40 (163)

6.60 (168)WIDTH

6.54 (166)

12.02 (305)

8.15 (207)

11.83 (300)

12.84 (326)LENGTH

3 Avenue Gutenberg - 77600 Bussy-Saint-Georges - FRANCETél. 01 71 58 26 10 - Fax. 01 71 58 26 15 - [email protected] - www.proxitech.com

Page 5: Fiche technique - Proxivolt · BATTERY CHARGE CONDITIONS (according DIN 41773 and DIN 41774) Charging profiles: WaW0 and IUIa Charge factor: 1.10 – 1.20. • Nominal voltage: 12

Pag

e 1/

1

Issu

e6102.20 :etad

12 V 120 Ah (C5) Light Traction Flooded BatteryPHYSICAL CHARACTERISTICS

SI Units

Length

Width 172 mm

Height 262 mm

Typical weight 37.3 kg 82.23 lbs

Specifications:

Performance characteristics:

It is mandatory to check the electrolyte level every 3 months and top up with deionized water to the markings.

BATTERY DISCHARGE PERFORMANCE AT 25oCDischarge rate C5 (5 h) C20 (20 h) C100 (100 h) Capacity at 25 AEnd of discharge voltage 10.20 V 10.50 V 10.80 V 10.50 VDischarge capacity 120 Ah 140 Ah 150 Ah 270 min / 112.5 Ah

Temperature correction factor of discharge C5 (5 h) capacityTemperature -10 oC 0 oC 20 oC 25 oC 30 oC 35 oC 40 oCCorrection factor 0.76 0.82 0.94 0.97 1.00 1.03 1.06

BATTERY CHARGE CONDITIONS (acc. DIN 41773, DIN 41774 and ZVEI recommendations)Charging profiles: WaW0 and IUIa Charge factor: 1.10 – 1.20

.

• Nominal voltage: 12 V• Rated capacity: 120 Ah (at C5 and 30 oC)• Plate technology: Antimony / Antimony• Separator: Polyethylene + glass mat• Electrolyte: Sulphuric acid; analytical grade• Standards: IEC 60254; IEC 60095; IEC 61427

• Case / Lid material: Polypropylene • Lid type: Flat• Terminal type: Top / Automotive• Carrying Handles: Available• Cycles at 75% DoD: more than 400• PVES applications: more than 800 cycles

PROXITECH S.A.S. 3 Avenue Gutenberg - 77600 Bussy-Saint-Georges - FRANCE - Tél. 01 71 58 26 10 - Fax. 01 71 58 26 15 - [email protected] - www.proxitech.com

Fiche technique 120T

WaW0-(double slope taper) characteristics for �ooded batteries) Charging times with WaW0-characteristics in hours for PzS batteries at 30°C

IUIa-characteristics for �ooded batteries Charging times with IUIa-characteristics in hours for PzS batteries at 30°C

344 mm 13.54 inch

6.77 inch

10.31 inch