WHITE PAPER Fiberstore White Paper | Digital Diagnostic Monitoring Introduction Cisco announced the end of sale of its SFP transceiver Cisco GLC-SX-MM transceiver and published a replacement—Cisco GLC-SX-MMD transceiver. The module numbers of the two transceiver only differ in one letter “D”. This “D” mainly represents a function of Cisco GLC-SX-MMD transceiver and is inherited by most of optical transceivers offered today. It is the main reason why Cisco GLC-SX-MMD transceiver can replace its predecessor. What is this “D”? Why the GLC-SX-MMD can replace GLC-SX-MM? This article is to offer the answers to these questions. What is Digital Diagnostic Monitoring (DDM)? “D” in GLC-SX-MMD represents the DDM function which is short for digital diagnostic monitoring according to the industry standard MSA (Multi-Source Agreement) SFF-8472 and is also known as DOM (Digital Optical Monitoring). When buy fiber optic transceiver today, you will have the option with or without DDM/DOM. And most of the modern transceivers are with the DDM function. This technology allows the user to monitor real-time parameters of the fiber optic transceivers, like optical input/output power, temperature, laser bias current, and transceiver supply voltage, etc. What Can Digital Diagnostic Monitoring Do? Literally, DDM function can provide component monitoring on transceiver applications in details. However, DDM’s application is not limited to this. The SFF-8472 added DDM interface and outlined that DDM interface is an extension of the serial ID interface defined in GBIC specification, as well as the SFP MSA. DDM interface includes a system of alarm and warning flags which alert the host system when particular operating parameters are outside of a factory set normal operating. Thus, DDM interface can also enable the end user with the capabilities of fault isolation and failure prediction. This part is to illustrate what can be done with DDM. Component Monitoring: The DDM enables the end user to monitor key parameters in the performance of the fiber optic transceiver including the following: Transceiver temperature Transceiver supply voltage Laser bias current Transmit average optical power Received optical modulation amplitude (OMA) or Average Optical Power Digital Diagnostic Monitoring Introduction

Fiberstore white paper digital diagnostic monitoring (ddm)

Embed Size (px)

DESCRIPTION

digital diagnostic monitoring (ddm) Introduction

Citation preview

WHITE PAPER

Fiberstore White Paper | Digital Diagnostic Monitoring Introduction

Cisco announced the end of sale of its SFP transceiver Cisco GLC-SX-MM transceiver and published areplacement—Cisco GLC-SX-MMD transceiver. The module numbers of the two transceiver onlydiffer in one letter “D”. This “D” mainly represents a function of Cisco GLC-SX-MMD transceiver andis inherited by most of optical transceivers offered today. It is the main reason why CiscoGLC-SX-MMD transceiver can replace its predecessor. What is this “D”? Why the GLC-SX-MMD canreplace GLC-SX-MM? This article is to offer the answers to these questions.

What is Digital Diagnostic Monitoring (DDM)?“D” in GLC-SX-MMD represents the DDM function which is short for digital diagnostic monitoringaccording to the industry standard MSA (Multi-Source Agreement) SFF-8472 and is also known asDOM (Digital Optical Monitoring). When buy fiber optic transceiver today, you will have the optionwith or without DDM/DOM. And most of the modern transceivers are with the DDM function. Thistechnology allows the user to monitor real-time parameters of the fiber optic transceivers, likeoptical input/output power, temperature, laser bias current, and transceiver supply voltage, etc.

What Can Digital Diagnostic Monitoring Do?Literally, DDM function can provide component monitoring on transceiver applications in details.However, DDM’s application is not limited to this. The SFF-8472 added DDM interface and outlinedthat DDM interface is an extension of the serial ID interface defined in GBIC specification, as well asthe SFP MSA. DDM interface includes a system of alarm and warning flags which alert the hostsystem when particular operating parameters are outside of a factory set normal operating. Thus,DDM interface can also enable the end user with the capabilities of fault isolation and failureprediction. This part is to illustrate what can be done with DDM.

Component Monitoring: The DDM enables the end user to monitor key parameters in theperformance of the fiber optic transceiver including the following: Transceiver temperature Transceiver supply voltage Laser bias current Transmit average optical power Received optical modulation amplitude (OMA) or Average Optical Power

Digital DiagnosticMonitoring Introduction

WHITE PAPER

Fiberstore White Paper | Digital Diagnostic Monitoring Introduction

The real-time diagnostic parameters can be monitored to alert the system when the transceiver’sspecified operating limits are exceeded and compliance cannot be ensured.

Fault isolation: The DDM function can be used to isolate the particular location of fault in fiber opticnetwork system. Combining the DDM interface status flags, transceiver hard pins and diagnosticparametric monitor data the specific location and cause of a link failure can be pinpointed.

Failure prediction: The DDM can also be used to help in failure prediction on fiber optic links, whichis based on the transceiver parametric performance. Although, this application is not yet fullymature, but there is still room for improvement. There are two basic types of failure conditions thatcan be seen on fiber optic transceivers:

Device faults—A device non-operation or malfunction. Typically applied more to transmitterperformance, due to nature of semiconductor lasers.

High error rate conditions—Operating conditions are such that transceiver is operating at itssignal-to-noise limit. Applies more to fiber optic receiver performance.

Providing parameter monitoring, fault isolation, and failure prediction, fiber optic transceivers withDDM help to ensure that the business can be proactive in preventative maintenance of the networkand ensure business continuity. And it would easy to explain why modern transceivers are withDDM and why GLC-SX-MMD can replace GLC-SX-MM. It is irresistible development trend of industryand technology.

What should be mentioned is that although optical transceivers with DDM are much popular thanthose without DDM, some user still use the older optical transceivers in consideration of theupgrading costs. To satisfy the customers’ needs, optical transceivers with DDM and without DDM

WHITE PAPER

Fiberstore White Paper | Digital Diagnostic Monitoring Introduction

are provided by Fiberstore, welcome to contact us for more detailed information.

Contact UsManufacturing R & D (China)

Eastern Side, Second Floor, Science &Technology Park, No.6, Keyuan Road,Nanshan District, Shenzhen 518057,ChinaTel: +86 (755) 8300 3611Fax: +86 (755) 8326 9395Email: [email protected]

APAC Office (Hong Kong)

1220 Tung Chun Commercial Centre,438-444 Shanghai Street, Kowloon,HongKongTel: +852 81763606Fax: +852 81763606Email: [email protected]

North America (United States)

331 Andover Park East Ste330, Tukwila,WA 98188,United StatesTel: +1-425-226-2035Fax: +1-253-246-7881Email: [email protected]

London Office (United Kingdom)

Third Floor 207 Regent Street, London,W1B 3HH, United KingdomTel: +44 2081441980

Notice: This document is for informational purposes only and does not set forth any warranty, expressed orimplied, concerning any equipment, equipment features, or service offered or to be offered by Fiberstore.Fiberstore reserves the right to make changes to this document at any time, without notice, and assumes noresponsibility for its use. This information document describes features that may not be currently available.Contact a Fiberstore sales team for information on feature and product availability.