Fulham Co., Inc extends limited warranty only to the original purchaser or to the fi rst user for the period of 5 years from the date of manufacture as indicated by the date code stamped on each product and when properly installed and under normal conditions of use. For additional warranty guide line, please refer to our complete product catalog or call customer service at 1-323-599-5000. DUE TO A PROGRAM OF CONTINUOUS IMPROVEMENT, FULHAM Co., INC RESERVES THE RIGHT TO MAKE ANY VARIATION IN DESIGN OR CONSTRUCTION TO THE EQUIPMENT DESCRIBED. Data is based upon tests performed by Fulham in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Address: 12705 S. Van Ness Ave., Hawthorne, CA 90250 Website: www.fulham.com To order this product: Fax: 1-323-754-9060 Email: [email protected] 2006-126-1 rev F SPECIFICATION SHEET : FH6-DUAL-3000L MECHANICAL DATA Description :Firehorse Emergency Ballast for use with or without AC ballast designed to add emergency lighting when main AC power is interrupted for minimum of 90 minutes at reduced illumination. The emergency ballast is not intended for general purpose lighting applications. This Is An Original Product From Fulham Co., Inc ELECTRICAL DATA Project_______________________Type______________Model #___________ Remarks__________________________________________________________ This Ballast Will Operate Following Single/Bi-Pin/4-Pin Lamps. NOTE: WIRING DIAGRAMS SHOWN ON A SEPARATE SHEET Partial list of lamps operated - contact Fulham Customer Service when referencing alternative lamps - lumen ratings may vary with lamp specifications, light loss, lamp and luminaire maintenance and other utilization factors. 5.56 1.88 16.25 15.75 15.43 R0.12 4.00 4xØ0.25 ONE OR TWO 17W TO 40W(2’-4’) T8/T10/T12 OR ONE 17W TO 110W (2’-8’) T8/T10/T12 INCLUDING COMPACT, HO, VHO, U-SHAPED, CIRCLINE, 4-PIN LONG COMPACT OR MOST 17W TO 215W (2’-8’) T8/T10/T12 OR ONE 8W TO 54W T5 FLUORESCENT LAMPAT REDUCED INITIAL ILLUMINATION (ALL WITHOUT INTEGRAL STARTER) FCRT5 T8 T12/T12HO T5 FT (LONG) T10 T8/T12 2D28/38W TRIPLE(CFTR/E) FH6-DUAL-3000L WITHOUT INTEGRAL STARTER 1 LAMP 2 LAMPS T12 40 G13/med-bipin 2600-2700 2600-2700 F96T12 75 FA8/single pin 2800 X F48T12HO 60 R17D/REC 3000 X F96T12HO 95 R17D/REC 2900 X F96T12VHO 215 R17D/REC 2900 X T8 25 G13/med-bipin 2250 X T8 32/40 G13/med-bipin 3000 X F96T8 59 FA8/single pin 3000 X FT(LONG) 39/36 2G11 2850 2850 FT(LONG) 40/30/50/55 2G11 1800 X F2D/4P 28/38 GR10Q-4 1800-2800 1800-2800 FCRT5 55 2GX13 2700 X T5/T5HO 28/54 min-bipin 2500-2700 X CFTR 42 GX24Q-4 2900-3000 2900-3000 CFTR 57/70 GX24Q-4 2700-2800 X WATTS BASE TYPE INITIAL LUMEN OUTPUT TABLE 1 LUMEN OUTPUT CHART Where : L = Length, W = Width, H = Height all in inches INPUT VOLT: 120V OR 277V ± 10%, 60Hz APPROVAL CLASS UL- LIS TED FOR DAMP LO C A T IO N – FACTORY OR FIELD INSTALLATION CODE COMPLIANCE MEETS OR EXCEEDS UL924 – N . E .C . AND LSC EMERGENCY OPERATING REQUIREMENT AC INPUT PO W ER RA TING 8.0WATTS AC INPUT CURRENT 280mA BA LLAST TYPE EMERGENCY MINIMUM ILLUMINATION T IM E 90 MINUTES RECHARGE TIME 24 HOURS M A X IM U M IN IT I A L L IG HT O UTPUT 3000 LUMENS BATTERY TYPE HIGH TEMPERATURE RECHARGABLE NI-CAD – MAINTENANCE FREE TEMPERATURE RATING (AMBIENT) 0°C TO 50°C (32°F TO 122°F) BATTERYVOLTAGE 14.4Vdc BATTERY CHARGING CURRENT 280mA Max. BATTERYRATING 57.6W h MINIMUM BATTERY R A T IN G 4.0Ah TEST S W IT C H SINGLE POLE CHARGING IN D IC A T O R LI G H T LED CASE TYPE VANDAL RESISTANT – SEALED CASE CONSTRUCTION PAINTED STEEL CASE P R O F IL E 16.3”L X 5.5”W X 1.7”H X 15.10” MOUNTING CENTER CASE W EIG HT 9.2 lbs. AC BALLAST C O M P A T IB I L IT Y ELECTRONIC FLUORESCENT – STANDARD AND DIMMING LAMP COMPATIBILITY FLUORESCENT SINGLE/BI-PIN / 4-PIN W IT H O UT STARTER F IX T U R E COMPATIBILITY INDOOR SW ITCHED AND UNSW ITCHED TYPE W IRE CONNECTION (STANDARD) SINGLE FLEX CONDUIT W HIP/STD. LEADS ONE END LED TEST S W IT C H TYPE (STANDARD) TEST SW ITCH & LED INDICATOR

FH6-DUAL-3000L This Is An Original Product From … Co., Inc extends limited warranty only to the original purchaser or to the fi rst user ... T8/T12 2D28/38W TRIPLE(CFTR/E) FH6-DUAL-3000L

  • Upload
    doxuyen

  • View
    215

  • Download
    0

Embed Size (px)

Citation preview

Fulham Co., Inc extends limited warranty only to the original purchaser or to the fi rst user for the period of 5 years from the date of manufacture as indicated by the date code stamped on each product and when properly installed and under normal conditions of use. For additional warranty guide line, please refer to our complete product catalog or call customer service at 1-323-599-5000.DUE TO A PROGRAM OF CONTINUOUS IMPROVEMENT, FULHAM Co., INC RESERVES THE RIGHT TO MAKE ANY VARIATION IN DESIGN OR CONSTRUCTION TO THE EQUIPMENT DESCRIBED.Data is based upon tests performed by Fulham in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions.Address: 12705 S. Van Ness Ave., Hawthorne, CA 90250 Website: www.fulham.com To order this product: Fax: 1-323-754-9060 Email: [email protected] 2006-126-1 rev F

SPECIFICATION SHEET :FH6-DUAL-3000L

MECHANICAL DATA

Description :Firehorse Emergency Ballast for use with or without AC ballast designed to add emergency lighting when main AC power is interrupted for minimum of 90 minutes at reduced illumination. The emergency ballast is not intended for general purpose lighting applications.

This Is An Original Product From Fulham Co., Inc

ELECTRICAL DATA

Project_______________________Type______________Model #___________

Remarks__________________________________________________________

This Ballast Will Operate Following Single/Bi-Pin/4-Pin Lamps.

NOTE: WIRING DIAGRAMS SHOWN ON A SEPARATE SHEET

Partial list of lamps operated - contact Fulham Customer Service when referencing alternative lamps - lumen ratings may vary with lamp specifications,

light loss, lamp and luminaire maintenance and other utilization factors.

5.56

1.88

16.25

15.75

15.43

R0.12

4.00

4xØ0.25

ONE OR TWO 17W TO 40W(2’-4’) T8/T10/T12 OR ONE 17W TO 110W (2’-8’) T8/T10/T12 INCLUDING COMPACT, HO, VHO, U-SHAPED, CIRCLINE, 4-PIN LONG COMPACT OR MOST 17W TO 215W (2’-8’) T8/T10/T12 OR ONE 8W TO54W T5 FLUORESCENT LAMP AT REDUCED INITIAL ILLUMINATION(ALL WITHOUT INTEGRAL STARTER)

FCRT5

T8

T12/T12HO

T5

FT (LONG) T10

T8/T12

2D28/38W

TRIPLE(CFTR/E)

FH6-DUAL-3000LWITHOUT INTEGRAL STARTER 1 LAMP 2 LAMPS

T12 40 G13/med-bipin 2600-2700 2600-2700

F96T12 75 FA8/single pin 2800 XF48T12HO 60 R17D/REC 3000 XF96T12HO 95 R17D/REC 2900 X

F96T12VHO 215 R17D/REC 2900 XT8 25 G13/med-bipin 2250 XT8 32/40 G13/med-bipin 3000 X

F96T8 59 FA8/single pin 3000 XFT(LONG) 39/36 2G11 2850 2850FT(LONG) 40/30/50/55 2G11 1800 X

F2D/4P 28/38 GR10Q-4 1800-2800 1800-2800

FCRT5 55 2GX13 2700 XT5/T5HO 28/54 min-bipin 2500-2700 X

CFTR 42 GX24Q-4 2900-3000 2900-3000

CFTR 57/70 GX24Q-4 2700-2800 X

WATTS BASE TYPEINITIAL LUMEN OUTPUT

TABLE 1LUMEN OUTPUT CHART

Where : L = Length, W = Width, H = Height all in inches

IN P U T V O L T : 1 20 V O R 27 7 V ± 1 0 % , 6 0 H zA P P R O V A L C L A S S U L - L IS TE D F O R D A M P L O C A T IO N – FA C T O R Y O R FI E L D IN S T A L LA T I O NC O D E C O M P L I A N C E M E E TS O R E X C E E D S U L 9 2 4 – N . E .C . A N D L S C E M E R G E N C Y O P E R A TI N G R E Q U I R E M E N TA C IN P U T P O W E R R A TI N G 8 . 0 W A T T SA C IN P U T C U R R E N T 2 8 0 m AB A LL A S T TY P E E M E R G E N C Y

M IN IM U M I L L U M IN A TI O N T IM E 9 0 M IN U T E SR E C H A R G E T I M E 2 4 H O U R SM A X IM U M IN IT I A L L IG H T O U T P U T 3 0 0 0 L U M E N SB A TT E R Y T YP E H IG H T E M P E R A T U R E R E C H A R G A B L E N I -C A D – M A IN T E N A N C E F R E E

T E M P E R A T U R E R A T I N G (A M B I E N T ) 0 ° C TO 5 0 °C (3 2 ° F T O 1 2 2 ° F)B A TT E R Y V O L T A G E 1 4 .4 V d cB A TT E R Y C H A R G IN G C U R R E N T 2 8 0 m A M a x.B A TT E R Y R A T I N G 5 7 .6 W hM IN IM U M B A T T E R Y R A T IN G 4 . 0A h

T E S T S W IT C H S I N G L E P O L EC H A R G I N G IN D IC A TO R LI G H T L E DC A S E TY P E V A N D A L R E S I S T A N T – S E A L E DC A S E C O N S T R U C T I O N P A I N T E D S T E E LC A S E P R O F IL E 1 6 .3 ”L X 5 .5 ”W X 1 . 7 ”H X 1 5 .1 0 ” M O U N T IN G C E N T E R

C A S E W E IG H T 9 . 2 lb s.A C B A L LA S T C O M P A T IB I L IT Y E L E C TR O N IC F L U O R E S C E N T – S T A N D A R D A N D D IM M IN GL A M P C O M P A T I B IL I TY F L U O R E S C E N T S I N G L E / B I-P I N / 4 -P IN W IT H O U T S T A R TE R

F IX T U R E C O M P A TI B IL I T Y I N D O O R S W I T C H E D A N D U N S W IT C H E D T Y P EW IR E C O N N E C T IO N (S T A N D A R D ) S I N G L E FL E X C O N D U IT W H I P /S T D . L E A D S O N E E N DL E D T E S T S W IT C H TY P E (S TA N D A R D ) T E S T S W I T C H & L E D IN D I C A T O R

Fulham Co., Inc extends limited warranty only to the original purchaser or to the fi rst user for the period of 5 years from the date of manufacture as indicated by the date code stamped on each product and when properly installed and under normal conditions of use. For additional warranty guide line, please refer to our complete product catalog or call customer service at 1-323-599-5000.DUE TO A PROGRAM OF CONTINUOUS IMPROVEMENT, FULHAM Co., INC RESERVES THE RIGHT TO MAKE ANY VARIATION IN DESIGN OR CONSTRUCTION TO THE EQUIPMENT DESCRIBED.Data is based upon tests performed by Fulham in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions.Address: 12705 S. Van Ness Ave., Hawthorne, CA 90250 Website: www.fulham.com To order this product: Fax: 1-323-754-9060 Email: [email protected] 2006-126-2 rev F

SPECIFICATION SHEET :FH6-DUAL-3000LThis Is An Original Product From Fulham Co., Inc

APPLICATIONThe FireHorse emergency ballast can be used to add emergency lighting with our without an AC ballast and with most fluorescent fixtures without affecting normal fixture operation. The emergency ballast is designed for factory or field installation and can be mounted on top, inside, or remote from the fixture.If used in an emergency-only fixture, no AC ballast is required. The FireHorse emergency ballast is not suitable for use in air handling heated air outlets, outdoor, wet, or hazardous locations. The emergency ballast should not be installed near gas or electric heaters. The FireHorse emergency ballast is rated for Indoor Dry/Damp locations and for sealed and gasketed fixtures, includingfixtures rated for UL wet locations .

OPERATIONThe FireHorse emergency ballast is designed to immediately switch to the emergency mode when the primary AC power is interrupted, illuminating one or two lamps at a reduced lumen output for a minimum of 90 minutes. Upon restoration of primary AC power; the FireHorse emergency ballast immediately returns to a battery charging mode. The LED indicator light source when illuminated indicates battery is in charge mode when AC power is applied. It is recommended and by code required to test the emergency ballast every 30 days to ensure that the ballast is functioning as evidenced by reduced illumination of one or two lamps when pushing the test switch. It is also recommended a 90 minute discharge test is performed one time every 12 months.

INSTALLATIONThe FireHorse emergency ballast may be used with either a switched or un-switched fixture. If a switched fixture is used, an un-switched hot lead must be connected to the emergency ballast to ensure the ballast remains in an uninterrupted charge condition while primary AC power source is active. Reference Installation Instructions for appropriate wiring or contact Fulham Customer Service.The FireHorse emergency ballast must be fed from the same branch circuit as the AC ballast.

The FireHorse emergency ballast may be remote-installed up to half the distance the AC ballast manufacturer recommends for remote mounting the AC ballast from the lamp, or up to 50 feet, whichever is less distance. The remote test switch plate may be mounted within 50 feet of the fixture and is subject to NEC and applicable local electrical code.

Installation is not recommended with fixtures where the ambient temperature may fall below 0° C for extended periods as this may affect the operation of the emergency ballast.

UL and CODE COMPLIANCEThe FireHorse emergency ballast has been tested by Underwriters Laboratories in accordance with the standards contained in UL924, “Emergency Lighting and Power Equipment”, and is UL approved for factory or field installations. Emergency illumination time meets or exceeds the National Electrical Code (NEC), Life Safety Code (NFPA-LSC) and UL 90 minute requirements.

BATTERYThe FireHorse emergency ballast contains a uniquely constructed, high-temperature rechargeable nickel cadmium battery.The battery is sealed within the ballast housing and is not replaceable. The battery must be recycled or disposed of properly andin compliance with federal, state and local regulations.

EMERGENCY ILLUMINATIONIllumination output varies with number of lamps, either 1 or 2 lamps, and lamp wattage requirement. The FireHorse model FH6-DUAL-3000L is designed to produce 1800-3000 initial emergency lumens output; if model works with 2 lamps the total initial lumens is distributed between the 2 illuminated lamps. Refer to Table 1 for average lumen output for selected lamps.

SPECIFICATIONEmergency lighting shall be provided by using a FireHorse emergency ballast with a standard fluorescent fixture equipped with or without an AC ballast. The emergency ballast shall be capable of operating one or two fluorescent lamps as referenced in Table 1. The emergency ballast shall conform to specifications contained in Electrical Data Table and comply with standards set forth by the current NEC. The emergency ballast shall be UL approved for installation on top, inside, or remote from the fixture.

Ni-Cd

ULR

Fulham Co., Inc extends limited warranty only to the original purchaser or to the fi rst user for the period of 5 years from the date of manufacture as indicated by the date code stamped on each product and when properly installed and under normal conditions of use. For additional warranty guide line, please refer to our complete product catalog or call customer service at 1-323-599-5000.DUE TO A PROGRAM OF CONTINUOUS IMPROVEMENT, FULHAM Co., INC RESERVES THE RIGHT TO MAKE ANY VARIATION IN DESIGN OR CONSTRUCTION TO THE EQUIPMENT DESCRIBED.Data is based upon tests performed by Fulham in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions.Address: 12705 S. Van Ness Ave., Hawthorne, CA 90250 Website: www.fulham.com To order this product: Fax: 1-323-754-9060 Email: [email protected] 2006-126-3 rev F

SPECIFICATION SHEET :FH6-DUAL-3000LThis Is An Original Product From Fulham Co., Inc

GREEN WIRE MUST BE GROUNDED

TYPICAL SCHEMATICS ONLY. MAY BE USED WITH OTHER BALLASTS. CONSULT THE FACTORY FOR OTHER WIRING DIAGRAMS

EMERGENCY BALLAST AND AC BALLAST MUST BE FED FROM THE SAME BRANCH CIRCUIT.

E. ONE (1) LAMP INSTANT START BALLAST F. TWO (2) LAMP INSTANT START BALLAST

G. THREE (3) LAMP INSTANT START BALLAST H. FOUR (4) LAMP INSTANT START BALLAST

J. TWO (2) 4-PIN COMPACT LAMP RAPID START BALLASTI. ONE (1) 4-PIN COMPACT LAMP RAPID START BALLAST

Connected to thebuilding g rounding

systemConnected to the

building g roundingsystem

Connected to thebuilding g rounding

system

Connected to thebuilding g rounding

system

Connected to thebuilding g rounding

system

Connected to thebuilding g rounding

system

GREENGREEN

GREENGREEN

GREENGREEN

INDICATOR LIGHT/TEST SWITCH INDICATOR LIGHT/

TEST SWITCH

INDICATOR LIGHT/TEST SWITCHINDICATOR LIGHT/

TEST SWITCH

INDICATOR LIGHT/TEST SWITCH

INDICATOR LIGHT/TEST SWITCH

Ni-Cd

ULR

Fulham Co., Inc extends limited warranty only to the original purchaser or to the fi rst user for the period of 5 years from the date of manufacture as indicated by the date code stamped on each product and when properly installed and under normal conditions of use. For additional warranty guide line, please refer to our complete product catalog or call customer service at 1-323-599-5000.DUE TO A PROGRAM OF CONTINUOUS IMPROVEMENT, FULHAM Co., INC RESERVES THE RIGHT TO MAKE ANY VARIATION IN DESIGN OR CONSTRUCTION TO THE EQUIPMENT DESCRIBED.Data is based upon tests performed by Fulham in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions.Address: 12705 S. Van Ness Ave., Hawthorne, CA 90250 Website: www.fulham.com To order this product: Fax: 1-323-754-9060 Email: [email protected] 2006-126-4 rev F

SPECIFICATION SHEET :FH6-DUAL-3000LThis Is An Original Product From Fulham Co., Inc

TYPICAL SCHEMATICS ONLY. MAY BE USED WITH OTHER BALLASTS. CONSULT THE FACTORY FOR OTHER WIRING DIAGRAMS

EMERGENCY BALLAST AND AC BALLAST MUST BE FED FROM THE SAME BRANCH CIRCUIT.

Ni-Cd

ULR

WIRING DIAGRAMS FOR 1-LAMP EMERGENCY OPERATION cont’d.

WIRING DIAGRAMS FOR 2-LAMP EMERGENCY OPERATIONEMERGENCY BALLAST AND AC BALLAST MUST BE FED FROM THE SAME BRANCH CIRCUIT

Two-lamp emergency operation is not possible with all ballasts. Consult the factory for any ballast other than those shown.

K. ONE (1) LAMP CIRCLINE RAPID START BALLAST L. TWO (2) LAMP CIRCLINE RAPID START BALLAST

NOTE: USE PROPER CAPS TO TAP UNUSED LEADS

M. TWO (2) LAMP RAPID START BALLAST N. TWO (2) LAMP INSTANT START BALLAST

O. THREE (3) LAMP RAPID START BALLAST P. THREE (3) LAMP INSTANT START BALLAST

Connected to thebuilding g rounding

system

Connected to thebuilding g rounding

systemGREENGREEN

Connected to thebuilding grounding

system

Connected to thebuilding grounding

system

Connected to thebuilding grounding

system

Connected to thebuilding g rounding

system

GREEN GREEN

GREENGREEN

INDICATOR LIGHT/TEST SWITCH

INDICATOR LIGHT/TEST SWITCH

INDICATOR LIGHT/TEST SWITCH

INDICATOR LIGHT/TEST SWITCH

INDICATOR LIGHT/TEST SWITCH

INDICATOR LIGHT/TEST SWITCH

Fulham Co., Inc extends limited warranty only to the original purchaser or to the fi rst user for the period of 5 years from the date of manufacture as indicated by the date code stamped on each product and when properly installed and under normal conditions of use. For additional warranty guide line, please refer to our complete product catalog or call customer service at 1-323-599-5000.DUE TO A PROGRAM OF CONTINUOUS IMPROVEMENT, FULHAM Co., INC RESERVES THE RIGHT TO MAKE ANY VARIATION IN DESIGN OR CONSTRUCTION TO THE EQUIPMENT DESCRIBED.Data is based upon tests performed by Fulham in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions.Address: 12705 S. Van Ness Ave., Hawthorne, CA 90250 Website: www.fulham.com To order this product: Fax: 1-323-754-9060 Email: [email protected] 2006-126-5 rev F

SPECIFICATION SHEET :FH6-DUAL-3000LThis Is An Original Product From Fulham Co., Inc

TYPICAL SCHEMATICS ONLY. MAY BE USED WITH OTHER BALLASTS. CONSULT THE FACTORY FOR OTHER WIRING DIAGRAMS

EMERGENCY BALLAST AND AC BALLAST MUST BE FED FROM THE SAME BRANCH CIRCUIT.

WIRING DIAGRAMS FOR 2-LAMP EMERGENCY OPERATION cont’d.

WIRING DIAGRAMS FOR EMERGENCY-ONLY FIXTURES

Q. FOUR (4) LAMP RAPID START BALLAST R. FOUR (4) LAMP INSTANT START BALLAST

S. ONE (1) LAMP WITHOUT AC BALLAST T. TWO (2) LAMPS WITHOUT AC BALLAST

U. ONE (1) 4-PIN COMPACT LAMP WITHOUT AC BALLAST V. TWO (2) 4-PIN COMPACT LAMPS WITHOUT AC BALLAST

NOTE: USE PROPER CAPS TO TAP UNUSED LEADS

Connected to thebuilding g rounding

system

Connected to thebuilding g rounding

system

Connected to thebuilding g rounding

systemConnected to the

building g roundingsystem

Connected to thebuilding g rounding

system

Connected to thebuilding g rounding

system

GREEN GREEN

GREENGREEN

GREENGREEN

INDICATOR LIGHT/TEST SWITCH

INDICATOR LIGHT/TEST SWITCH

INDICATOR LIGHT/TEST SWITCH

INDICATOR LIGHT/TEST SWITCH

INDICATOR LIGHT/TEST SWITCH

INDICATOR LIGHT/TEST SWITCH

Ni-Cd

ULR

Fulham Co., Inc extends limited warranty only to the original purchaser or to the fi rst user for the period of 5 years from the date of manufacture as indicated by the date code stamped on each product and when properly installed and under normal conditions of use. For additional warranty guide line, please refer to our complete product catalog or call customer service at 1-323-599-5000.DUE TO A PROGRAM OF CONTINUOUS IMPROVEMENT, FULHAM Co., INC RESERVES THE RIGHT TO MAKE ANY VARIATION IN DESIGN OR CONSTRUCTION TO THE EQUIPMENT DESCRIBED.Data is based upon tests performed by Fulham in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions.Address: 12705 S. Van Ness Ave., Hawthorne, CA 90250 Website: www.fulham.com To order this product: Fax: 1-323-754-9060 Email: [email protected] 2006-126-6 rev F

SPECIFICATION SHEET :FH6-DUAL-3000LThis Is An Original Product From Fulham Co., Inc

Ni-Cd

ULR