106
FEMAP Post-Processing Tools Realize innovation. Unrestricted © Siemens AG 2016

FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

FEMAP Post-Processing Tools Realize innovation. Unrestricted © Siemens AG 2016

Page 2: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 2 Siemens PLM Software

Topics

Results Locations

Post Toolbox Overview

Output Transformation

Output Listing

Results Ranking

Charting

Analysis Studies

Output Data Surfaces

Loads from Output

Beam Calculator

Results-Based Selection

API – Results Browsing Object

Page 3: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 3 Siemens PLM Software

Introduction

FEMAP offers a wide variety of tools available for post-processing as well as automatic results-based tasks

This presentation provides an introduction to many of the tools available to the analyst

Functionality presented represents what is available as of FEMAP v11.3

Page 4: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 4 Siemens PLM Software

Results Location

Results files in FEMAP for many different analysis types may be either internalized or attached • Internalized results are stored completely within the model

• Attached results reference the output file from the model

Page 5: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 5 Siemens PLM Software

Results Location

Once results are either internalized or attached they’re treated exactly the same within the Model (no changes to workflow are required) FEMAP currently supports attached results for • NASTRAN XDB, OP2 • FEMAP FNO • Abaqus ODB • CSV

Result Type Pros Cons Internalized Results • Simple file management

• May be marginally faster with smaller result files

• Increased database size; can impact overall FEMAP performance

Attached Results • Greatly improved performance for large results files

• Greatly improved performance for transient results

• Multiple results files may be attached in a single operation

• When transmitting model, results file(s) must be transmitted with the model

Page 6: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 6 Siemens PLM Software

Results Location

Attach behavior for analyses that are launched from within FEMAP and automatically imported controlled via a preference that is off by default

Page 7: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 7 Siemens PLM Software

Results Location

The Results File Manager, under File->Attach to Results provides an interface to manager results files that have been attached • When opening a model which

has missing results, FEMAP will display a warning message, then present options for locating the results and reattaching

• Results files are compared via a checksum to determine if the results in the attached results file are identical to the results when the file was originally attached. If a discrepancy is found, a warning is issued

Page 8: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 8 Siemens PLM Software

Contour Plots Displaying Multiple Contour Vectors

Line element results can be displayed with other element types in a contour plot • Multiple Contour Vectors option displays solid, shell and line element results in

the same contour plot (or multiple line elements types: Bar, Beam, Bush, etc)

Page 9: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 9 Siemens PLM Software

Contour Plots Setting Threshold Value(s)

A Max Threshold or Max/Min Threshold can now be set for contour plots using the Level Mode of the Contour/Criteria Levels view option • Contour Fill Mode must be set to Level Colors Example: Max Threshold Value = 4000, Min Threshold Value = 750

Page 10: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 10 Siemens PLM Software

Post Toolbox Overview

The Post-Processing Toolbox provides a single interface for accessing Deformation plots, Contour plots and Freebody plots, each of which has a separate Tool in the toolbox

Page 11: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 11 Siemens PLM Software

Post Toolbox Overview Deform Toolbox – Deformed Plots

Deformed plots show a deformed display of a single output set

• Output Set – used for all deform, contour and Freebody plots

• Output Vector – used for all deformed plots

• Transform - Select transformation options

• None, Nodal Output CSys or Model CSys

• When transforming results, different components of deformation can be selected for display

Page 12: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 12 Siemens PLM Software

Post Toolbox Overview Deform Toolbox – Deformed Plots

• Scale – Scale deformations • % of model (exaggerated) • Actual deformations

• Deform Relative To

• Origin • Fixed point

• Undeformed Model – enables display and

other options for undeformed plot

Page 13: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 13 Siemens PLM Software

Post Toolbox Overview Deform Toolbox – Deformed Plots

Total deformation plot with undeformed model shown

Page 14: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 14 Siemens PLM Software

Animated plots show an animation of a deformation within a single Output Set, while Multi-Set Animated plots allow the selection of a Starting and Ending Output Set to show deformations across time or frequency

Post Toolbox Overview Deform Toolbox – Animate / Animate Multi-Set

• Animation – options for animation • Shape (single set animation only)

• Linear / Sine • Full, Full Abs, Half, Half Abs

• Frames – Number of Frames (single set animation only)

• Delay - delay between frames, in milliseconds • Animation Control – Animation Control dialog

Adjusting the delay between the frames inversely controls the number of frames / sec

Page 15: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 15 Siemens PLM Software

Contour plots show a color contour for results on shell and solid elements

Post Toolbox Overview Contour Toolbox – Contour

• Output vector – used for all contour styles • Additional vector(s) – specify up to two

additional output vectors when displaying plots of entity types, such as displaying plate stresses with solid stresses (i.e., Multiple Contour Vectors)

• Transform – Contour transformation options • Data Conversion – Options for handling corner /

centroidal data • No averaging • Average • Maximum • Minimum • Centroid only • Average, centroid only • Max, centroid only • Minimum, centroid only

Page 16: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 16 Siemens PLM Software

Post Toolbox Overview Contour Toolbox – Contour

• Discontinuity options for data conversion which are used to determine when NOT to average results on connected elements

• Not If Property Change – Do not average between elements having different Properties

• Not If Material Change – Only available when Not If Property Change is disabled – Do not average between elements having different Materials

• Not If Layer Change – Do not average between elements on different Layers

• Not If Color Change – Do not average between elements having different element Colors)

• Not if Exceed Angle – Do not average when elements have a “break angle” between elements which exceeds the specified value

Page 17: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 17 Siemens PLM Software

Post Toolbox Overview Contour Toolbox – Contour

• Data Selection – Choose from Contour Group, Visible Groups(s), or All Data/Full Model (when set to Contour Group, uses the group ID or other option set for Show On Groups)

• Type – Select a Contour Type from Match Output (default), Nodal, or Elemental

• Double-Sided Planar – Enables display of double-sided contour vectors for shell elements with top and bottom fiber results

• Show On Groups – Limit display of contour results to Full Model/Visible Groups, the Active Group, or a single Group ID (available for all contour types)

Page 18: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 18 Siemens PLM Software

Post Toolbox Overview Contour Toolbox – Contour

Contour plot of plate top von Mises, corner averaging on Contour plot of plate top von Mises, no averaging, centroidal only

Page 19: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 19 Siemens PLM Software

Post Toolbox Overview Contour Toolbox – Contour Level Options

Contour Levels options are available for all Contour styles

• Level Mode • Automatic, based on Data Selection option • Max/Min – user defined maximum and

minimum • User Defined – user defined max/min and

individual contour levels • Max Threshold – sets a maximum threshold

value where values above this user-defined value are colored with the upmost color band

• Max/Min Threshold

• Contour Palette • Choose between Standard Palette or User

Palette (colors selected by user) • Click button to specify Colors, choose

combinations of Standard Colors and/or set Specified Levels via dialog

Page 20: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 20 Siemens PLM Software

Post Toolbox Overview Contour Toolbox – Contour Level Options

Contour Level options are available for all Contour styles

• Number of Contour Levels – specify the number of levels which will appear on the model and in the Contour Legend

• Continuous Colors – toggle between Continuous (blended) and Discrete colors between contour levels

• Animate – link contour colors to animated plots

• Label Max/Min (Contour style only) – Choose to label Max Value, Min Value, or both Max/Min Values at appropriate location in model display

Page 21: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 21 Siemens PLM Software

Post Toolbox Overview Contour Toolbox – Contour Legend Options

Contour Legend options are available for all Contour styles

• Legend – toggle to display Contour Legend • Position – choose Legend position • Label color – display labels using View Color

or Contour Colors • Exponential Labels – toggle to show labels as

exponents • Label Erase Background – Draw a solid

background color behind the label, making it easier to read

• Label Freq – Labeling frequency in legend • Label Digits – Number of digits shown for

contour legend values • 0 = Auto

• Shrink To % – Shrink contour legend to percentage

Page 22: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 22 Siemens PLM Software

Criteria plots show discrete values for shell, solid and beam results, similar to contour plots without averaging, however the results can be labeled and pass/fail criteria can be set to display certain regions

Post Toolbox Overview Contour Toolbox – Criteria

• Limits Mode – defines a “pass” criteria for results • No Limits – all results pass • Above Maximum – values above the maximum pass • Below Minimum – values below the maximum pass • Between – values above the minimum and below the

maximum pass • Outside – values above the maximum and below the

minimum pass • Display options for Elements that Pass the stated criteria

• Display • Label • Color

• Display options for Elements that Fail the criteria

Elements that fail the criteria will not be filled

Page 23: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 23 Siemens PLM Software

Ex: Contour plot showing plate top von Mises stress. Pass criterion set to above 450psi, failed elements are drawn, but not labeled

Post Toolbox Overview Contour Toolbox – Criteria

Page 24: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 24 Siemens PLM Software

Beam diagrams can be used to plot beam data along the length of beam elements in a fashion similar to shear or moment diagrams

Post Toolbox Overview Contour Toolbox – Beam Diagram

• Show As – Choose to display as a Beam Diagram or as a Beam Contour (i.e., Label Mode set to Contour Only)

• Label – Choose a Label Mode from No Labels, Label at Nodes, or Label at Peaks

• Direction – Direction for Beam Diagrams (End B can be reversed for all options)

• Element Y • Element Z • Global X • Global Y • Global Z

• Show Reversed – toggle to display Beam Diagrams in opposite direction (different than reversing End B values)

• Scale % – Adjust size of beam diagram • Border Color – Select View Color for border of Beam

Diagrams

Page 25: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 25 Siemens PLM Software

Ex: Beam Diagram plot of Beam End A Bending Moment

Post Toolbox Overview Contour Toolbox – Beam Diagram

Page 26: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 26 Siemens PLM Software

Section Cut plots can be used to display slices of contour data in solid models

Post Toolbox Overview Contour Toolbox – Section Cut

• Cut Options – Select section cut method • Cut Model – single cut at defined plane • Parallel Sections – multiple equally spaced

cuts offset from the defined plane • Multiple Sections – up to 3 separately

defined planes • Cutting Plane – Specify location of Cutting

Plane(s) and additional options • Dynamic Control – used to interactively

move the cutting plane in real time (i.e., View->Advanced Post->Dynamic Cutting Plane command)

Page 27: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 27 Siemens PLM Software

Post Toolbox Overview Contour Toolbox – Section Cut

Cut Model Parallel Sections Multiple Sections

Page 28: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 28 Siemens PLM Software

Arrow plots show one or more output vectors as arrows on nodes or elements

Post Toolbox Overview Contour Toolbox – Arrow

• Selected Output Vector (Contour Vector) is used as a “seed” vector

• Related Output Vectors will be selected and automatically paired (default)

• Styling and orientation is handled automatically (default)

User overrides for all automatically selected options are available Non-directional quantities, such as temperature or von Mises stress, require a user-defined direction

Page 29: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 29 Siemens PLM Software

Post Toolbox Overview Contour Toolbox – Arrow

• Solid Arrows – toggle to display as solid arrows

• Arrow Length – value to control length of arrows

• Scale by Magnitude – toggle to scale length of arrows with respect to output value

• Min Vector Magnitude – specifies a minimum magnitude for display

• Arrow Labels – Label Mode for Contour Arrows Label

• Off • On • Exponent

Page 30: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 30 Siemens PLM Software

Post Toolbox Overview Contour Toolbox – Arrow

Arrow Plot Examples

Plate principals • Double-headed arrows • Located at center

Plate membrane • Single-headed arrows • Located at tip • Designed to show

directions for positive shear flow

Beam axial / shear • Axial shown with

double-ended arrows at center

• Shear shown with single headed arrows at tip

Page 31: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 31 Siemens PLM Software

Post Toolbox Overview Freebody Toolbox

The Freebody Toolbox is used to create and display freebodies. Freebodies created in the Freebody Toolbox can be selected for display in any view

• Global Settings – These controls affect all freebodies in the model. Control global display of freebodies, select output set (tied to contour and deform) and enable data summation on nodes

• Freebody Properties – These controls are related to individual freebodies, such as selecting nodes and elements

• View Properties – These are global settings that affect freebody visualization (symbol sizes, vector scaling, etc). Same as found in View Options (F6)

Page 32: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 32 Siemens PLM Software

Creating a New Freebody • In the Freebody Toolbox, new Freebody Displays are created within the

Freebody Manager

• The New Freebody dialog allows for setup of basic settings, such as freebody

display mode, vector display, and contribution selection • Any of the settings applied in the New Freebody dialog can be changed at any

time within the toolbox

Post Toolbox Overview Freebody Toolbox – Creating a Freebody

Page 33: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 33 Siemens PLM Software

FEMAP Freebody Display Modes – There are three methods of freebody display in FEMAP • Freebody – user selects the elements, FEMAP automatically selects related

nodes. Intended to display a balanced set of loads on a discrete piece of structure

• Interface Load – user selects both nodes and elements and FEMAP calculates a summation of loads and forces across the interface and displays as a single vector

• Section Cut – similar to interface load, a summed load across an interface is calculated and displayed, however node and element selection is automated by FEMAP. The user selects a “cutting plane”. The cutting plane can then be dynamically located within the model using different methods.

Post Toolbox Overview Freebody Toolbox – Freebody Types

Page 34: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 34 Siemens PLM Software

Post Toolbox Overview Freebody Toolbox

Interface Load Display, Showing Summed Shear Load at a Rib

Selected Elements Highlighted

Selected Nodes Highlighted

Page 35: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 35 Siemens PLM Software

Post Toolbox Overview Freebody Toolbox – Results Validation

The Freebody Toolbox includes a tool for results validation that can be useful in debugging models and results. It can help warn about missing results

FREEBODY RESULTS VALIDATION SUMMARY

Freebody: 1..Sample Freebody Output Set: 1..NX NASTRAN Case 1

Selected Nodes: OK Selected Elements: OK

Applied Results: OK Reaction Results: OK Multi Point Reaction Results: OK Freebody Element Results: Not Requested Peripheral Element Results: OK Contact Results: Not Requested Glue Results: Not Requested Nodal Summation Results: Not Requested

Do selected nodes / elements exist in the model?

Do results for valid node / element pairs exist?

Does the output vector exist?

Does the output vector exist?

Page 36: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 36 Siemens PLM Software

Post Toolbox Overview Freebody Toolbox – Results Validation

When potential discrepancies have been found in the model / selected results, the icon changes to a warning:

FREEBODY RESULTS VALIDATION SUMMARY

Freebody: 1..Untitled Output Set: 2..NX NASTRAN Case 1

Selected Nodes: OK Selected Elements: OK

Applied Results: OK (Alternate vectors used) Reaction Results: OK (Alternate vectors used) Multi Point Reaction Results: OK Freebody Element Results: Not Requested Peripheral Element Results: Missing Results Contact Results: Not Requested Glue Results: OK Nodal Summation Results: Not Requested

“Alternate vectors” indicates results were not obtained with GPFO request. Usually okay,

but may indicate an issue if unexpected.

Use of alternate vectors does

not cause a warning flag in the validation icon

When elemental results have an error, this indicates that

results for the node / element pair do not exist in the results.

This data can optionally be

listed with discrepant node/element pairs

Page 37: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 37 Siemens PLM Software

Output Transformation

Transformation of results can be done on-the-fly for use within views and certain listing options, or the results can be calculated and stored as new output vectors • Output can be transformed on-the-fly for deformed and contour plots • Output can also be transformed and stored within the model

Plate membrane forces with element orientation Plate membrane forces transformed to global rectangular CS

Page 38: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 38 Siemens PLM Software

Output Transformation Deformed Results Transformations

Deformed results can be transformed into any model coordinate system or the nodal output coordinate system • Selected components of the

deformation in the global coordinate system can be selected for transformation

• When displaying deformations of total (resultant) vectors, display of individual components can be toggled on and off

Deformation transformations are done on-the-fly for visualization and do not affect the data stored in the model

Page 39: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 39 Siemens PLM Software

Output Transformation Contoured Results Transformations

Contoured results for nodal output, plate output and solid output can be transformed into a variety of orientations

• Nodal • Model Coordinate System • Nodal Output CS

• Plate • Material Direction (must be defined) • Into CS

• When transforming into a coordinate system the selected axis represents where the X vector will be transformed to

• Results should be selected in accordance to this • Along a Vector

• Solid • Model CS • Material Direction (must be defined)

Contour transformation options are valid for all contour styles, except Beam Diagram and do not affect the data stored in the model

Page 40: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 40 Siemens PLM Software

Output Transformation Elemental Results Orientation

For elemental results to be properly displayed or transformed, the results orientation needs to be properly set • Normally this shouldn’t be changed unless the solver output is oriented

differently than expected

Page 41: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 41 Siemens PLM Software

Output Transformation Model->Output->Transform

In addition to transforming results for deformed and contour display, the Model->Output->Transform command can be used to transform data and store it within the model itself • This can be useful for listing • Avoids calculation in the future • Stored as “User Vectors” in the

9,000,000 ID range

Page 42: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 42 Siemens PLM Software

Working with Complex Output Complex Results Options

• On-the-fly postprocessing of complex data by specifying a Static Display Phase Angle and/or Animation Phase Increment to see actual results

• Model Settings – Options used for entire model • View Override – Options used for Active View only

Page 43: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 43 Siemens PLM Software

Working with Complex Output Static Display Phase Angle

• Specify Static Display Phase Angle to display “Total” vectors (i.e., Total Translation) using both Magnitude and specified Phase Angle

• Principal Stresses and Mean Stress will be calculated “on-the-fly” for display • Static Display Phase Angle appears in Post Titles for reference

Page 44: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 44 Siemens PLM Software

Output Listing

FEMAP provides multiple tools for listing output data to a variety of destinations such as the Message Window or Data Table • Query Tool • Entity Selector • Results Comparison • Data Table Tools

• Results • Contoured Results • Nodal Changes

• Force Balance Data • Entity Selector and Output Data • Results Ranking

Page 45: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 45 Siemens PLM Software

Output Listing Query

List->Output->Query provides a quick and simple way for listing results data to the clipboard for user-selected entities to the message window • Any number of output sets / vectors may be selected, however it’s best used

when only selecting a limited number of output cases or vectors • When selecting vectors, both nodal and elemental vectors may be selected,

however only those related to the entity type will be listed

1. Select results 2. Select entities 3. Results listed to message window

Page 46: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 46 Siemens PLM Software

Output Listing Entity Selector

The FEMAP Entity Selector can also be used in conjunction with the Entity Info window to quickly list deformation and contour results for single entities

• Enable the Entity Selector by selecting the type of entity to activate for selection

• Enable the Entity Info pane… by default its docked with the Entity Editor pane below the Model Info Tree

Page 47: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 47 Siemens PLM Software

Output Listing Entity Selector

With the selector enabled, hover over an entity (node or element) with the mouse to display posted results data

Page 48: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 48 Siemens PLM Software

Output Listing Entity Selector - Tooltips

Enable Tooltips in the Selector to show Tooltips in the graphics window

Page 49: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 49 Siemens PLM Software

Output Listing Entity Selector - Tooltips

Right Click on the Tooltip and select Convert to Text to have the Tooltip persist in the model. Created Text boxes will rotate with the model Use Delete->Tools->Text to remove converted Text boxes

Page 50: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 50 Siemens PLM Software

Output Listing Output Comparison

List->Output->Compare allows for comparison of results between two or more output sets and one or more output vector(s) • Optionally compare results across the

entire output set • User specifies the maximum difference

between results for a given entity (0% difference will also output identical vectors

• Tool will output maximum and minimum difference

• Listing details will include entity-by-entity summaries

Page 51: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 51 Siemens PLM Software

Output Listing Results to Data Table

List->Output->Results to Data Table allows for listing of a large amount of output data to the Data Table • Listing to the Data Table provides a tabular format that can easily be copied to

Excel or other programs • All the Data Table functionality such as grouping, sorting and highlighting is

available • Various configurations are available for arranging data in rows and columns

Selecting which options appear in rows and columns depends largely on how the data will be sorted

Page 52: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 52 Siemens PLM Software

Plate Membrane Forces listed to data table with Output Sets and Elements in rows and Output Vectors in Columns. All plate elements selected

Output Listing Results to Data Table

Page 53: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 53 Siemens PLM Software

Click on column headings to sort based on column

Output Listing Results to Data Table – Data Table Sorting

Page 54: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 54 Siemens PLM Software

Turn on Column Header and drag columns into the header to enable grouping

With grouping enabled, sorting of columns now occurs within the selected grouping, in this case, sorting of Nxx within each selected output set

Output Listing Results to Data Table – Data Table Grouping

Page 55: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 55 Siemens PLM Software

Output Listing Results to Data Table – Data Table Highlighting

Turn on highlighting and select rows in the Data Table to highlight the related entities in the view

Select multiple rows by holding down either the CTRL or SHIFT key

Page 56: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 56 Siemens PLM Software

Output Listing Contoured Results to Data Table

List->Output->Contoured Results to Data Table will list the results used to create the active contour plot to the Data Table Output set and vector will match the active view

Page 57: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 57 Siemens PLM Software

Output Listing Nodal Changes to Data Table

List->Output->Nodal Changes to Data Table can be used to calculate differences in distance and angle between undeformed and deformed or differences in output values between multiple nodes • When listing distance and angle, select

between total translation or total rotation • When selecting difference in output value,

select any resultant nodal output vector • Can be used to calculate changes in a

single output set or across all output sets • Reports differences between a single

“from” node and one or more “to” Node(s) • Select any coordinate system for output

orientation

Page 58: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 58 Siemens PLM Software

Distance between node 1 and node 128 across 100 output sets Distance between single constrained node and wingtip nodes in a single set

Output Listing Nodal Changes to Data Table

Page 59: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 59 Siemens PLM Software

Output Listing Freebody Listing – Force Balance

Force balance data, including interface loads can be listed using the List->Output->Force Balance command Shortcuts for listing Force Balance data and Interface Load data are available in the Freebody Toolbox

1. Select data to list 3. Select freebody data

2. Select listing destination

Page 60: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 60 Siemens PLM Software

Output Listing Freebody Listing – Force Balance

List->Output->Force Balance: Listing Options • List contribution details – when requested, prints

contribution data, such as elemental or constraint contributions, for each node in the freebody

• Include all contributions – includes all possible contributions in the freebody; useful for duplicating “f06-style” data; Force Balance listing only

• Calculated nodal sums – when requested, prints the FEMAP calculated summation at each node, based on the selected contributions

• Calculation details – lists each nodal contribution to the interface load calculation including calculated forces, moments and moment arms

• List interface load – for each freebody, lists the calculated interface load

Page 61: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 61 Siemens PLM Software

Output Listing Freebody Listing – Force Balance

List->Output->Force Balance: Output Destinations • Message Window – data is sent to the message window in the standard listing

format • Data Table – data is sent to the data table in a spreadsheet-like format • Clipboard – data is copied to the clipboard in a tab-delimited format, similar to

the Data Table destination

Page 62: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 62 Siemens PLM Software

Output Listing Freebody Listing – Force Balance Interface Load Summary

List->Output->Force Balance Interface Load Summary can be used to compare interface loads across multiple freebodies or multiple output sets

FREEBODY INTERFACE LOAD SUMMARY, OUTPUT SET - 6..NX NASTRAN Case 6

Freebody ID Fx Fy Fz Mx My Mz 5 1500. 1500. 1500. -280.072 -401.5093 681.5813 6 1576.018 880.9498 -948.885 -37797.73 12807.21 7791.901 7 1500. 1500. 1500. -88389.63 93190.53 -4800.9

Max value 1576.018 1500. 1500. -280.072 93190.53 7791.901 Max FB 6 7 7 5 7 6 Min value 1500. 880.9498 -948.885 -88389.63 -401.5093 -4800.9 Min FB 5 6 6 7 5 7

Page 63: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 63 Siemens PLM Software

Output Listing Freebody Listing – Force Balance Interface Load Summary

List->Output->Force Balance Interface Load Summary Output can be used to create functions for plotting

Page 64: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 64 Siemens PLM Software

Output Listing Freebody Listing – Freebody Section Cuts

List->Output->Freebody Section Cuts command can be used to list interface loads for a section cut freebody at variable locations along the cutting path

• Interface loads can be calculated at equal spacing along the path through the model, or at pre-determined locations using an “Along Coordinates” data surface

• Equal spacing locations will output locations at the start, end and any number of points between along the path

• When specifying a data surface, either arbitrary coordinates can be specified for a plane / point intersection or if the path is defined as a curve, a percentage of the curve length (between 0 and 1.0)

Page 65: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 65 Siemens PLM Software

Results Ranking

The List->Output->Results Ranking to Data Table command can be used to envelope results across output sets • Returns extreme output sets for

selected entities/ materials/properties, or extreme entities/properties/materials for selected output sets

• Vectors can be ranked individually or all vectors can be treated as a single quantity

• Results quantities can be ranked on max value, min value or max absolute, for any number of “top” cases

• Works on both internalized and attached output

Page 66: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 66 Siemens PLM Software

Results Ranking

Example: Find the 5 maximum result cases for plate membrane forces across all elements in the model

Grouping is based on element ID

Page 67: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 67 Siemens PLM Software

Results Ranking

Example: Find the 5 elements with maximum plate membrane forces across all output sets in the model

Grouping is based on output set ID

Page 68: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 68 Siemens PLM Software

Results Ranking Output to FNO

When using the Results Ranking tool to find worst-case entities or output sets on a global-level FEM, the PostProcessing->GROUP_POST_FNO Custom Tool can be used to export a portion of the results for local analysis • Select a group containing entities for output • Select output set(s) and vector(s) for export • FEMAP will export a neutral file containing the only the selected entities and

output quantities When exporting results for grid point forces, it’s important to select all the GPFO output vectors (85000 range) as well as ensuring that the group for export contains the elements of interest as well as those connected to the elements of interest. Failure to do so could potentially result in unbalanced freebodies.

Page 69: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 69 Siemens PLM Software

Charting

The Charting Pane provides a simple interface for creating plots of output data as well as function data without relying on an external program, such as Excel • Tools->Charting • Separate pane, like the API

Programming Window or Data Table • Create Data Series within the

Charting Pane that serve as source data for the charts

• Create individual Charts to display Data Series with individual styles

• Charts and Chart Data Series are stored in the database and persist across FEMAP sessions

• Charts automatically update if output changes

Page 70: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 70 Siemens PLM Software

Charting Chart Data Series

Chart Data Series are “data sources” that are used to retrieve output or function data from the model for display in individual charts • Multiple types available

• vs. Entity • vs. Output Set • Vector vs. Vector • Function

• Data is retrieved from the model real-time – if the results or function data is updated, this is automatically reflected in the plot without user interaction

• By default, Chart Data Series that are created are automatically added to the active Chart

Page 71: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 71 Siemens PLM Software

Charting Charts

Once a Chart Data Series has been created, it can be displayed in a Chart

• Any number of charts can be created in a model

• Several different styles exist • Scatter plot • Line • Step • Area

• Control over • Colors • Axis labeling • Title • Fonts • Markers • Labels

Page 72: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 72 Siemens PLM Software

Charting Charts

Scatter Plot No Legend

Area Plot Large Triangle Markers

Step Plot Dark Background

Page 73: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 73 Siemens PLM Software

Charting Tooltips

Tooltips can be enabled on charts to show detailed values over hovered points • Options for data to include in tooltip

• X / Y Value • Data Series • Output Set • Output Vector • Entity ID

• Hovered entity can be highlighted in the active view

• View can be synced to tooltip (output set and/or vector)

Page 74: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 74 Siemens PLM Software

Analysis Studies

Analysis Studies allow the organization of Results Sets into “groups” of results sets • Manually create or automatically created at

the successful completion of an analysis • Default behavior is to create a new

study for each analysis • This can be modified in

Preferences->Results • All Result Sets are always shown in the

All Results leaf, regardless of their inclusion into an Analysis Study

• A result set may reside within only a single Analysis Study at one time

Page 75: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 75 Siemens PLM Software

Analysis Studies Naming Conventions

Various naming convention options exist for Analysis Studies and can be set in Preferences->Results

• Default – Nastran title (if available) for OP2 and XDB, otherwise file name

• Analysis Set Title – Use the Analysis Set title for jobs launched from FEMAP. When importing results manually, the active Analysis Set is used – this may not correspond to the actual Analysis Set

• File Name – Use the file name of the output file

• Nastran Title – Use the Nastran title, for OP2 or XDB. Otherwise, “Analysis Study” is the default title

Page 76: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 76 Siemens PLM Software

Analysis Studies Naming Conventions – Output Sets

Similar to Analysis Studies, options exist for naming of Nastran Output Sets as well

• Standard – Solver, subcase and value (when applicable)

• TITLE • SUBTITLE • LABEL • SUBTITLE,LABEL

• Use the “Append Femap Title” option to

append the output set value to any of the options other than “Standard”. This can be useful for output sets with an associated value, such as modal runs, non-linear, and eigenvalue runs

Page 77: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 77 Siemens PLM Software

Analysis Studies Naming Conventions – Static Subcase IDs

When the “Use Static Subcase IDs” option is enabled in Preferences, the output set ID will correspond to the NASTRAN Static Subcase ID

Page 78: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 78 Siemens PLM Software

Analysis Studies Revision Tracking

When, “Track Revision” is enabled, subsequent runs of the same Analysis Set or importing a single file again will result in a revision number being appended

Because duplicate IDs may not be used with output sets, if this option is used in conjunction with “Use Static Subcase ID,” the Output Set ID is incremented from the subcase ID with the revision number

Page 79: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 79 Siemens PLM Software

Multi-set animation can quickly be accessed for Analysis Studies by right clicking on a study and selecting “Animate” • Animate Multi-Set will automatically be set

as the deformation plot • Starting and ending output sets for

animation are set to the first and last output set in the analysis study

Analysis Studies Animation

Page 80: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 80 Siemens PLM Software

Analysis Studies Enveloping

Envelopes of Analysis Studies can quickly be created by right clicking on a study an selecting one of the envelope options • Max Value • Min Value • Max Absolute Value

• Each option creates two new

output sets in the database • Value • Associated output case

• “Create in Database” will calculate the results and save them in the model; otherwise they’re calculated on-the-fly as needed

Page 81: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 81 Siemens PLM Software

Analysis Studies Plotting

Quick plots can be created of Analysis Studies by right clicking on a study and selecting the Plot Study options • Translation vs Output Set • Acceleration vs Output Set • Temperature vs Output Set

• Automatically creates data series

for selected quantity and adds it to the “Quick Plot” chart

• Can be created vs Output Set ID or Output Set Value

Page 82: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 82 Siemens PLM Software

Output Data Surfaces Results Processing Data Surface

The Results Processing Data Surface can be used to generate combination or enveloped output sets

Page 83: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 83 Siemens PLM Software

Output Data Surfaces Results Processing Data Surface

Spreadsheet-like interface for creation of Output Sets • Combination factors can be pasted from a

Spreadsheet • Results can be created and stored in the

model or calculated on-the-fly • Right-click to Create Processed Result Sets

Page 84: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 84 Siemens PLM Software

Output Data Surfaces Load Set Combination Data surface

Similar to the Results Processing Data Surface, the Load Set Combination Data Surface provides a spreadsheet-like interface to create Load Set combinations • Load Sets can be created as

standalone sets or as Nastran Load Combination Sets

Page 85: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 85 Siemens PLM Software

Loads from Output From Output

The Model->Load->From Output command can be used to convert output data to loads in a model • Select the type of load to create • Select the to use as the basis for

the load • Output does not have to used to

create identical load types • For most vectors, six vectors

are selected for six DoF • Pressures, temperatures and

heat transfer loads only select a single DoF

• Select entities to take output data and apply loads

Page 86: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 86 Siemens PLM Software

Loads from Output Map Output from Model

While Model->Load->From Output should be used to create loads within the same model on an identical mesh, Model->Load->Map Output from Model can be used to create loads between dissimilar models using interpolation / extrapolation routines

• Select a source model • Optionally limit results data to a group • Select output set and vector

• For resultant vectors, such as total displacement or total rotation, the components are automatically created by selecting the total

• Select the data mapping routine for entities outside of the tolerance

• Zero • Constant value • Extend closest • Interpolate • None

• Select load to create in target model

Page 87: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 87 Siemens PLM Software

Ex: Translation mapped to displacement

Loads from Output Map Output from Model

Note: When mapping to SPCD, corresponding SPC needs to be created as well

Page 88: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 88 Siemens PLM Software

Loads from Output From Freebody

The Model->Load->From Freebody command will create loads from freebodies that exist in the model. This command is intended to be used when creating loads in the same model as the results • Select one or more freebodies • Select one or more output set(s)

• Loads can be created as a new

definition in an existing set (only when single output set is selected), or in a new load set

• Optionally create loads for nodal summations or interface load

• Creating a load for the interface load will create a new node at the summation point

Page 89: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 89 Siemens PLM Software

Loads from Output From Freebody

Freebody loads….

… applied to model

Page 90: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 90 Siemens PLM Software

Loads from Output From Freebody… Multi-Model

When applying loads from a coarse-grid global model to a fine-grid detail model, the Multi-Model option in the Load->From Freebody command should be used • Start with a balanced freebody in a coarse

grid FEM • FEMAP can automatically locate suitable

target nodes in the fine grid FEM and will connect with RBE3 elements

• Once properly constrained, the detail FEM is ready to run with a mapped set of loads

Page 91: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 91 Siemens PLM Software

Loads from Output From Freebody… Multi-Model

Source Model Freebody(Global Model)

Target Model with RBE3 Load Distribution

Page 92: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 92 Siemens PLM Software

Beam Calculator

The FEMAP Beam Calculator provides detail section stresses on a line element using beam forces recovered via a standard analysis - A local finite-element solution is

used to calculate section stresses - Any solver may be used as a

“source” for the forces used in the calculations

- Multiple stress calculations are available, including von Mises, max shear, max/min principal, axial, Y/Z shear and combined shear

- Requires line elements with a section

Page 93: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 93 Siemens PLM Software

Beam Calculator Basic Setup

View->Advanced Post->Beam Cross Section - Select Output Set - Select forces from Output Set to include in calculations

Vector IDs used for forces are dependent on element type (bar, beam, etc) as well as solver (Nastran, Abaqus, Ansys, etc) and are automatically selected by FEMAP

Info

*

Page 94: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 94 Siemens PLM Software

Beam Calculator Basic Setup

- Select element(s) to display; either single or multiple elements can be displayed

- Select stress component to display

Single Element Display Multiple Element Display

Page 95: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 95 Siemens PLM Software

Beam Calculator Section Location

The section location (from end A to end B) can be modified using the slider, or manually specifying an option - By default, only a single section is displayed at the selected location

- Enabling multiple sections will perform calculations / display at end A, end B and the equally-spaced points in between (2 to 10)

- Default of 3 displays sections at end A, the midpoint and end B - Contour plots can be displayed either in screen space or model space

- When displaying in screen space, only a single section for a single element can be displayed

Page 96: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 96 Siemens PLM Software

Beam Calculator Section Location

Model Space Screen Space

Page 97: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 97 Siemens PLM Software

Beam Calculator Combined Shear Vector Plot

When displaying Combined Shear Stress quantities, the results may be viewed as a contour vector plot to visualize the direction of shear flow

Page 98: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 103 Siemens PLM Software

Results-Based Selection

The entity selector can be used to select nodes and elements based on results • This type of selection is available using the

standard selector any time nodes or elements are being selected, regardless of the intended operation

• Ex: change the property of shell elements by selecting those above a certain stress level

• Any number of output sets may be selected for filtering

Page 99: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 104 Siemens PLM Software

Results-Based Selection

Multiple selection criteria may be set based on varying output conditions Keep in mind that the filtering is done at selection – groups created using these selection tools will not be updated if the output changes

Page 100: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 105 Siemens PLM Software

API Results Browsing Object

The FEMAP API provides multiple ways for accessing results data, however generally the most efficient way is to use the Results Browsing Object Notionally, the Results Browsing Object is very similar to the FEMAP Data Table:

Page 101: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 106 Siemens PLM Software

API Results Browsing Object - Usage

The FEMAP Results Browsing Object is a read-only object. Its primary function is to access a “table” of data, however it can also replicate many of the output set / vector querying methods of the OutputSet and Output objects. Unlike the Output object, the Results Browsing Object allows for access to results from many different output sets and vectors via a single API call. Methods are grouped into three categories: - Setup & population - Results set / vector information - Results access / manipulation

Except in rare circumstances, the Results Browsing Object SHOULD NOT be used to access results one-at-a-time; performance may be poor.

Caution

!

In most cases, the Results Browsing Object can be used as a direct replacement for the OutputSet and Output objects

Info

*

Page 102: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 107 Siemens PLM Software

API Results Browsing Object - Usage

Create Results Browsing Object

Add Columns

Specify Required Data / Entities

Populate

Dim fRB As femap.Results Set fRB = app.feResults

Object Creation:

Page 103: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 108 Siemens PLM Software

Example: Get max plate vonMises stress in Output Set 1 Sub Main

Dim App As femap.model

Set App = feFemap()

Dim fr As femap.Results

Dim fsElem As femap.Set

Dim nCol As Long

Dim nColIDs As Variant

Dim nMinID As Long

Dim nMaxID As Long

Dim dMinVal As Double

Dim dMaxVal As Double

Set fr = App.feResults

Set fsElem = App.feSet

API Results Browsing Object - Usage

Declare RBO

Set RBO

Page 104: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 109 Siemens PLM Software

Example: Get max plate vonMises stress in Output Set 1

fr.AddColumn( 1, 7033, False, nCol, nColIDs )

fsElem.AddAll( FT_ELEM )

fr.DataNeeded( FT_ELEM, fsElem.ID )

fr.Populate()

fr.GetColumnMinMax( 0, 0, nMinID, nMaxID, dMinVal, dMaxVal )

App.feAppMessage( FCM_NORMAL, "Max plate top VM stress: " + _

Str$(dMaxVal) + " at element " + Str$(nMaxID) )

End Sub

API Results Browsing Object - Usage

Add Column for output set 1, vector 7033

Request results for all elements

Populate the data table

Use GetColumnMinMax to get min and max values

Page 105: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 110 Siemens PLM Software

API Access popular output commands programmatically

It is possible to run some list output commands programmatically

• List->Output->Results to Data Table • App.feResultsToDataTable

• List->Output->Results Ranking to Data Table • App.feResultsRankingToDataTable

• Select Output Sets using typical “Select Output Set” dialog box with check

boxes and filtering found in many commands • App.feSelectOutputSets

Page 106: FEMAP Post-Processing Toolsrokach/instr/Siemens/FEMAP_Post... · 2017-05-06 · has missing results, FEMAP will display a warning message, then present options for locating the results

Apr 2016

Unrestricted © Siemens AG 2016

Page 111 Siemens PLM Software

API Access popular output commands programmatically

• Select Output Sets and Output Vectors using typical “Select Output Set” dialog box with check boxes and filtering

• App.feSelectOutput