Energy Saving Technology
in cooperation with
Innovative energy saving systems electric power lines
(0.4 kV voltage class)
1
Best Solutions to optimize energy consumption!
Do you know that current in a socket never complying with
standards 220 V or 230 V, 110 V or 120 V? Yes, that
statement is absolute truth. You barely found 220 V or
230V, 110 V or 120 V (depends on country accepted
standard) it’s almost always plus or minus 5-10%. Usually,
in large cities voltage close to the upper tolerance range.
For example, in a country where 220 V taken as a basic in
network will be 225V-235V and even more. Distributors
increase the voltage to control subsidence at peak power
consumption.
This increase is a main cause of
“unnecessary” electricity use and unreasonable electric bill.
By implementing our technology electricity distributors
simply can optimize consumption by reducing the voltage
to the border which close to the lowest acceptable
standards. Why when you reduce the voltage decreases
consumption? The answer is simple:
S=U (Volts) x I (Amps) / PF
I = U / R- Ohm’s law.
So when we reduce the Voltage that we reduce the strength of the current (Amps) , respectively we reduce consumption (kW)
For example, in a country where 220 V standard used, in
network will be 212 V - 218 V optimal range achieved by
implementation of our equipment. This voltage is safe for
all consumers of electricity, increases the life of electrical
equipment, optimize energy consumption.
Our equipment can be used for ordinary electricity consumers (lamps, light bulbs, appliances, etc.) as well as asynchronous motors. Why not use conventional stabilizers for optimization?
The answer is obvious. Efficiency of the equipment
produced by our company to 99.7%. All other stabilizers
and transformers efficiency is 95% -97%. This means that
the use of conventional stabilizers ineffective, and even
cause of loss. Due to controller management interface all units can be
integrated into a global power system with ability of distant
measuring and recording of power and energy
consumption in almost any period of time and remotely
operate the equipment.
2
The most overwhelming problems with electrical network pertain to overvoltage and insufficiency of voltage. In recent decades, the demand for electricity has been
increasing. In order to ensure that the required voltage
levels are met for all users within the same infrastructure
voltage fluctuations consistently range within 10% due to
the changes in demand from the network. This means that
many institutions receive higher voltage than what is
actually required, which leads to higher energy
consumption, equipment failure, and a reduction in the
lifetime of equipment.
When the voltage output is stabilized at an optimal level
you not only reduce the wastage of energy , but also
extend the lifespan of equipment.
helps solve the problems
of network overloads and insufficient network loads via the
optimization of energy consumption.
Smart-Optimizer ECOD voltage optimization solution!
by reducing wastage. The system includes the capa-bility
of programming, energy measurement and management,
as well as protective mechanisms, including automatic
and manual shift modes; both including bypass functions.
Our equipment provides the control input voltage
operating range of 170-260 V, as well as the regulation of
each phase independently.
This Integrated Controller provides optimization of voltage energy levels for all loads and saves energy
Smart-Optimizer “ECOD” (Energy Consumption Optimizer Device) Voltage regulation to optimize power consumption with power-saving features and operational control modes for the induction motor
3
BLOCK OF DIFFERENTIAL PROTECTION Designed for the protection of control systems POWER UNIT Designed for the protection of control systems POWER TERMINAL BLOCK “LOAD” Designed for switching chains supplying power
COMMUTATION BLOCK Establishes commutations in the system in accordance with the changing of modes
CONTROL BLOCK AND SYSTEM INDICATOR Designed for the output of control signals AUTOMATIC LEAD-IN BREAKER Protective communication device BLOCK OF ELECTRIC PHASE FILTERS
ELECTRO-MAGNETIC POWER TRANSFORMERS Executes the function of electro-magnetic phase impacts
COMMUTATION BLOCK
Smart – Optimizer ECOD can be used for ordinary electricity consumers (MIX LOAD) as well as
asynchronous motors.
Implements few functions in a single units Provides several advantages, including:
- Optimization of energy consumption - Minimize the typical system losses
- Power factor correction - Increase the efficiency of the energy system
- Harmonic filtering - Reduced maintenance costs for equipment
- Balancing phases - Increased reliability of electrical equipment
- Limit the maximum inrush current - Providing the possibility of increasing the number of devices
- Solving problems with short-term voltage drops - Lightning protection
Why not use conventional stabilizers for optimization?
The answer is obvious. Efficiency of the equipment produced by our company to 99.7%. All other stabilizers and transformers
efficiency is 95% -97%. This means that the use of conventional stabilizers ineffective, and even cause of loss.
Due to controller management interface all units can be integrated into a global power system with ability of distant measuring and
recording of power and energy consumption in almost any period of time and remotely operate the equipment.
4
THE SCOPE OF OUR EQUIPMENT
1
Commercial and industrial buildings (i.e. hotels,
office buildings, shopping centers, factories) Better mediation of energy utilized by equipment reduces
the volume of energy consumed. This helps to extend the
service life of electrical equipment and reduces the cost of
its maintenance by protecting it from power surges.
3
Induction Motors
Our devices not only saves energy and protects motors
from power surges, but also reduces the risk of tripping
when the motor voltage drops below acceptable ranges,
which is very important for factories with a continuous
production cycle.
2
Street Lighting Smart-Optimizer ECOD provides up to 28% energy
savings for the following reason: Voltage control of a network of street lights reduces the cost of maintenance of
lamp replacement. Smart-Optimizer ECOD allows lighting fixtures require a
lower amount of energy without affecting the amount of
lighting, but significantly reduces cost. Advantages include:
• Easy installation, anywhere. A lightweight and compact unit means easy installation on any open apparatus for lighting control.
• Fast return on investment within 10 – 24 months. • Reduces the cost of maintenance by prolonging the
life of lamps. • No additional charges to the existing
infrastructure. The finished product Smart-Optimizer ECOD lighting provides immediate
energy efficiency and savings.
5
4
Power grid arrays (Long lines 0.4 kV): Solutions for units with insufficient voltage
Smart-Optimizer ECOD reduces energy transmission
losses via a reduction of power requirements by creating a system of energy reserves that can be used for other
needs.
This diagram (below) displays electricity consumers with converted voltages after FEIGIN ELECTRIC solution has been installed. For an electrical network that has consumers with voltage
levels that are too high (240 – 230V), which can cause
damage to equipment, as well as other consumers
suffering from insufficient voltage (209 – 190V) at the
same time, we can resolve this disparity with the use of Smart-Optimizer ECOD
Transformer Substation 10/0.4 kVa
Smart-Optimizer Smart-Optimizer
Before 244 V
After 232 V
Smart-Optimizer Smart-Optimizer
Before 239 V
After 227 V
Smart-Optimizer Smart-Optimizer
Before 232 V
After 220 V
Smart-Optimizer Smart-Optimizer
Before 227 V
After 215 V
Smart-Optimizer Smart-Optimizer Before 218 V
After 218 V
Smart-Optimizer
Before 200 V After 212 V
We will help you to use electricity efficiently thanks6
We will help you to use electricity
efficiently thanks
Smart-Optimizer ECOD
EFFICIENCY -For example air conditioners Series 1 -efficiency;
Series 2 - current (Amper); Series 3 - external fan;
Series 4 - internal fan; According to the scheme, we can clearly see
that the efficiency of air conditioner at a voltage
of 210 to 220, is close to 100%.
This means that with this voltage is optimal for
the optimal use of electricity at close to 100%
efficiency.
FOR ASYNCHRONOUSE MOTORS
Series 1
130
Series 2
Series 3
120 Series 4
%
110
eff
icie
ncy 100
90
80
70
60
170 180 190 200 210 220 230 240
Load , V
FOR MIX LOAD
CURRENT-VOLTAGE DIAGRAM
Current (Amp)
Load (V)
235 V Smart-Optimizer
100 Amp ECOD
90 Amp
222 V
0 Amp
WITHOUT LOAD With LOAD but without use With LOAD and with use Smart-Optimizer ECOD Smart-Optimizer ECOD
7
SMART-OPTIMIZER "ECOD"
OPERATING PRINCIPLE
1
R Ic T
In
Normal voltage on the main W2
At the core of Smart-Optimizer
ECOD technology is a small U Uc W1 Un Rn
power transformer, which operates
as an autotransformer with the
transformation ratio verging on 1:1.
2
Boosted voltage on the main By switching over the loaded
transformer’s high voltage winding
without breaking the circuit the Smart-Optimizer ECOD selects the optimum
operation mode depending on the
conditions of the exterior power lines.
3
Reduced voltage on the main Using the Smart-Optimizer ECOD helps
save between 7 – 20% of consumable
electric power by operating at the
optimum level for consumers.
T
R Ic W2 In
I1
U2
U Uc
W1 Un
Rn
T
R Ic W2 In
I1
U2
U Uc
Un
Rn
W1
client’s power supply in order to detect its problems and limitations.
FEIGIN ELECTRIC Implementation Process.
- Analysis of the client’s power supply in order to
detect its problems and limitations.
- Recommendations for improvement – Determination
of type of equipment configuration and investment
cost.
- Equipment delivery, assembly, installation, and
activation.
Post sales service and maintenance guarantee.