Michael Pacholok, Chief Purchasing Official and Director Purchasing & Materials Management City Hall 19th Floor, West 100 Queen Street West Toronto, Ontario M5H 2N2 Joanne Kehoe, Manager Construction Services February 16, 2017 Via E-mail (75 pages) Addendum No. 2 TENDER No. 345-2016 Closing: 12:00 NOON (LOCAL TIME), February 28, 2017 (REVISED) For: the supply of all materials, equipment, labour and supervision necessary for the construction of the Wellesley Community Centre Phase 2 Indoor Pool Addition. Please refer to the above Tender Call document in your possession and be advised of the following: 1.0 REVISED - Closing Date: The closing date has been extended from February 21 to 12:00 Noon, Local Time, February 28, 2017 The last day for questions is 1:00 pm., February 21, 2017 Additional information will follow shortly. 2.0 CLARIFICATIONS & REVISIONS, Section 4, Scope of Work: Please refer to Architectural Addendum No. 2 dated February 15, 2017 (71 pages total) which also includes: Electrical Addendum ADD-E01 dated February 14, 2017 (5 pages), and Mechanical Addendum ADD-M01 dated February 14, 2017 (1 page) and be governed accordingly. 3.0 RESPONSES TO QUESTIONS The following are responses to questions received during the call period: Q1. Regarding sidewalk along Bleecker Street: 1. Site Plan & Grading Plan show: Existing Sidewalk; 1 of 75

February 16, 2017 Via E mail (75 pages) Addendum …...Refer to specification section 31 41 00 1.4.2.1 regarding lagging tolerances. Weepers and insulation should be able to be installed

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • Michael Pacholok, Chief Purchasing Official and Director

    Purchasing & Materials Management City Hall 19th Floor, West 100 Queen Street West Toronto, Ontario M5H 2N2

    Joanne Kehoe, Manager Construction Services

    February 16, 2017 Via E-mail (75 pages)

    Addendum No. 2

    TENDER No. 345-2016

    Closing: 12:00 NOON (LOCAL TIME), February 28, 2017 (REVISED)

    For: the supply of all materials, equipment, labour and supervision necessary for the

    construction of the Wellesley Community Centre Phase 2 Indoor Pool Addition.

    Please refer to the above Tender Call document in your possession and be advised of the

    following:

    1.0 REVISED - Closing Date:

    The closing date has been extended from February 21 to 12:00 Noon, Local Time,

    February 28, 2017

    The last day for questions is 1:00 pm., February 21, 2017

    Additional information will follow shortly.

    2.0 CLARIFICATIONS & REVISIONS, Section 4, Scope of Work:

    Please refer to Architectural Addendum No. 2 dated February 15, 2017 (71 pages total)

    which also includes:

    Electrical Addendum ADD-E01 dated February 14, 2017 (5 pages), and

    Mechanical Addendum ADD-M01 dated February 14, 2017 (1 page) and be governed accordingly.

    3.0 RESPONSES TO QUESTIONS

    The following are responses to questions received during the call period:

    Q1. Regarding sidewalk along Bleecker Street:

    1. Site Plan & Grading Plan show: Existing Sidewalk;

    1 of 75

  • Addendum No. 2

    TENDER No. 345-2016 2

    2. Removal Plan shows: Remove Conc. Paving – Retain Sub-base; but it looks like the existing sidewalk at the new addition side keeps untouched;

    3. Layout & Material Plan: the whole sidewalk looks all new. The illustrations above conflict. Please advise.

    A1. This has been addressed in this addendum as part of ARCHITECTURAL DRAWING REVISIONS + CLARIFICATIONS.

    Q2. Please note that several areas have indicated to remove existing concrete and asphalt; however no make-ups are provided for the existing assembly. Please

    advise on the make-up breaking out the thickness of the different asphalt or

    concrete make-ups with the granular bases.

    A2. This has been addressed in this addendum as part of ARCHITECTURAL DRAWING REVISIONS + CLARIFICATIONS.

    Q3. Please confirm addition F.F. elevation due to the following discrepancies:

    Regarding the Finished Floor Elevation:

    Grading Plan C-01 shows 111.55;

    Drawing S101 says (Note 1): The Ground floor datum (+0.0) corresponds

    to the finished floor of the existing building, denoted as geo. Elevation

    110.95 in the SR;

    Drawing A301 shows 110.95;

    Survey Plan A001 shows 110.97

    A3. There is a discrepancy between the as-built architectural drawings which note the ground floor FFE as 110.95 and the survey which indicates 110.97. Contractor to

    verify existing FFE on site prior to the start of construction. C-01 to be corrected

    to match verified FFE prior to construction. Noted revision of FFE on C-01 does

    not affect the current grading or storm water management plan.

    Also note that 111.55 is the correct elevation for the north-west end (existing gym

    and change rooms) of the building.

    Q4. Please refer to both Structural and Architectural plans and sections relating to the exterior foundation wall running along Gridline X from 10x to 16z, you are

    currently showing installation of weeping tile and insulation on the exterior of the

    wall; however, there are no details showing how this foundation wall will relate

    to the shoring wall built directly in front. With the proximity of the wall to the

    property line we believe that the foundation wall will have to be poured against

    the shoring. Please review and advise.

    A4. The line of shoring is indicated on plan S101 and is outboard of the property line. Refer to specification section 31 41 00 1.4.2.1 regarding lagging tolerances.

    Weepers and insulation should be able to be installed in this configuration with

    the noted tolerances. Contractors can propose to set the formwork directly against

    2 of 75

  • Addendum No. 2

    TENDER No. 345-2016 3

    the lagging if this proves more cost effective with the understanding that details

    and specifications would change to suit.

    Q5. Please confirm the base material for the area of unit pavers that must be removed.

    A5. As-built drawing detail 7/L-400 (not issued) indicates unit pavers on 150mm compacted granular ‘A’, 200mm compacted granular ‘B’ on compacted subgrade.

    Contractor to site verify as-built conditions.

    Q6. Re: Door Schedule

    1) Please provide details of door types D2F, D-2G not shown with other door elevations, but is indicated on door schedule.

    2) Please confirm if door ST-A2 is to have frame type F-05 as noted which is Alum or F-03 which is HM. The finish is noted as PTD so wasn't sure what

    the frame material would be.

    3) Door ST-1A is shown to have frame type F-03 which is shown to have a transom panel, however there is no information regarding transom in the

    column "Transom", possibly this frame is to be F-01.

    4) Material Type is not indicated for door 164A, please advise. 5) Door 167A references HM Doors with WD Transom, please confirm if this is

    correct, possibly should be a HM Transom Panel

    A6. Please note the following responses

    1. D2F-D2G were mislabeled and replaced. Refer to reissued sheet A801

    2. F-03 is correct. Refer to reissued sheet A801

    3. F-01 is correct. Refer to reissued sheet A801

    4. Door Material type is HM. Refer to reissued sheet A801

    5. HM Transom Panel is correct. Refer to reissued sheet A801

    Q7. Please provide specification for wood doors noted on door schedule.

    A7. New specification section 08 14 00 issued with Addendum 2.

    Q8. With reference to the experience and qualifications forms for the Mechanical and Electrical contractors, we noticed the requirements has been revised to

    experience with indoor pool projects or Community Centres projects but the

    explanation paragraph still requires indoor pool projects as a component within

    a larger centre Please review and clarify

    A8. The intent of the change is to recognize the experience of either having:

    1. completed an indoor pool as described in the Tender documents, (pool can be stand alone or part of a larger centre – but the pool doesn't have to be part of a

    larger centre), or

    3 of 75

  • Addendum No. 2

    TENDER No. 345-2016 4

    2. completed a community centre with a minimum 50,000 sq. foot GFA - The community centre doesn't need to have a pool in it.

    Should you have any questions regarding this addendum, please contact Mike Voelker at

    [email protected].

    Please attach this addendum to your RFT document and be governed accordingly. Bidders must

    acknowledge receipt of all addenda on the space provided on the Tender Call Cover Page as per

    the Process Terms and Conditions, Section 1, Item 8 - Addenda, of the Tender Call document.

    All other aspects of the Tender remain the same.

    Yours truly,

    Joanne Kehoe,

    Manager, Construction Services

    Purchasing and Materials Management

    4 of 75

    mailto:[email protected]

  • Wellesley Community Centre Phase 2 – Pool Addition Addendum 02MacLennan Jaunkalns Miller Architects Page 1Project No. 1311 February 15, 2017

    General ADD2

    Addendum 02Issued February 15, 2017

    Project: Wellesley Community Centre Phase 2 – Pool AdditionOwner: City of TorontoConsultant: MacLennan Jaunkalns Miller Architects

    1. GENERAL

    .1 This Addendum shall be attached to the front of the specifications and shall be brought to the attention of all concerned.

    .2 This Addendum shall form an integral part and shall be read in conjunction with Specifications and Drawings. This Addendum shall take precedence over all requirements to the aforementioned specifications with which it may prove to be at variance.

    .3 Receipt of this Addendum shall be acknowledged on the Bid Form. Failure to do so may subject the Proponent to disqualification.

    .4 This Addendum Contains:

    .1 Part 1: GENERAL – 1 page

    .2 Part 2: ARCHITECTURAL SPECIFICATION REVISIONS + CLARIFICATIONS – 1 page

    .3 Part 3: ARCHITECTURAL DRAWING REVISIONS + CLARIFICATIONS – 9 pages of Architectural Drawing Revisions and Clarifications, 21 sketches with prefix “ADD2” and 3 full size sheets (A406, A600, A801)

    .4 RFI RESPONSES – Refer to the City of Toronto addendum documents

    .5 Electrical Addendum ADD-E01 dated February 14, 2017 (5 pages)

    .6 Mechanical Addendum ADD-M01 dated February 14, 2017 (1 page)

    .7 FULL SIZE drawings reissued as included or noted in the individual addendums listed above.

    5 of 75

  • Wellesley Community Centre Phase 2 – Pool Addition Addendum 02MacLennan Jaunkalns Miller Architects Page 1Project No. 1311 February 15, 2017

    Architectural Specifications ADD2

    2. ARCHITECTURAL SPECIFICATION REVISIONS + CLARIFICATIONS

    A. Section 08 14 00 – Flush Wood DoorsADD new specification section contained herein (7 pages)

    B. Section 08 71 00 – Finish HardwareREVISE hardware schedule with updated version dated February 10 217 contained herein (23 pages)

    C. Section 08 80 00 – Glass and GlazingADD paragraph 2.2.9:

    .9 Back painted glass (GL-BP):

    .1 Tempered, low-iron glass meeting requirements of ASTM C1048-12e1, kind HS, kind FT coated and uncoated, 6 mm (1/4") thick, minimum, epoxy coating on No. 2 surface, ‘MagiCoat’, by Imagic Glass.

    .1 Colour: to later selection by Consultant

    .2 Low iron glass acceptable Products:

    .1 AGC ‘Krystal Klear’.

    .2 Guardian ‘Ultraclear’.

    .3 Pilkington ‘Opti-White’.

    .4 PPG ‘Starphire’.

    .5 Saint-Gobain ‘Diamente’.

    .3 Acceptable manufacturers:

    .1 Central Canadian Glass.

    .2 Imagic Glass.

    .4 Supply and install adhesive compatible with coating and suitable for adhering glassto substrates, as recommended by glass manufacturer.

    D. Section 09 31 01 – Tiling Schedule

    ADD to paragraph 1.2: (Speciality Tiles) Provide tile stair treads with custom radius edge and continuous safety strip routed into tile (both by manufacturer). Provide tile stair risers cut to suit.

    END OF ARCHITECTURAL SPECIFICATION REVISIONS + CLARIFICATIONS.

    6 of 75

  • Wellesley Community Centre Phase 2: Pool Addition Section 08 14 00City of Toronto Page 1Project No. 1311 February 15, 2017

    Flush Wood DoorsSection issued by Addendum No. 02

    PART 1 - GENERAL

    1.1 Summary

    .1 Section includes:

    .1 Solid core doors with wood veneer.

    .2 Factory finishing wood doors.

    .3 Fire rated wood doors.

    1.2 Submittals

    .1 Submit required submittals in accordance with Section 01 33 00.

    .2 Product data sheets:

    .1 Submit manufacturer’s Product data sheets for Products proposed for use in thework of this section.

    .3 Shop drawings:

    .1 Indicate door location using numbering system per door schedule, size, and handof each door, elevation of each door type; undercuts, bevelling, construction typecore and edge construction not covered in product data; and special blockingrequirements.

    .2 Indicate dimensions and locations of factory machining criteria for hardware, extentof hardware blocking.

    .3 Indicate dimensions and locations of cut-outs including trim for openings.

    .4 Indicate door face finish requirements including veneer matching.

    .5 Indicate doors to be factory finished and finish requirements.

    .6 Indicate fire ratings for fire rated doors.

    .7 Indicate electrified hardware requirements and preparations.

    .4 Verification samples:

    .1 Submit cut-away sample of each type of door, to show stile and rail construction,core, cross banding, door face finish and edges.

    .2 Submit solid lumber frames for light openings, minimum 150 mm (6") long, for eachmaterial, type and finish required.

    1.3 Quality Assurance

    .1 Quality standard:

    .1 Work shall be in accordance with the Architectural Woodwork Standards Edition2-2014, Premium Grade.

    1.4 Delivery, Storage, and Handling

    .1 Door numbers shall be marked with door numbers used on shop drawings in the top hingecavity created by the machining for hinges.

    7 of 75

  • Wellesley Community Centre Phase 2: Pool Addition Section 08 14 00City of Toronto Page 2Project No. 1311 February 15, 2017

    Flush Wood DoorsSection issued by Addendum No. 02

    .2 Identify doors with labels. Package with resilient packaging.

    .3 Store doors flat at the Place of the Work in piles with bottom face on bottom of pile. Protectfrom moisture by placing water resistant material under skids supporting piles. Cover topof piles and provide air at sides of piles.

    .4 Deliver the wood doors only after the building is closed and dry and HVAC system isoperating and maintaining ambient temperature and humidity conditions at occupancylevels during the remainder of the construction period. Do not receive the doors in a damparea. Do not drag the doors on the ground, floor or across one another.

    PART 2- PRODUCTS

    2.1 Manufacturer

    .1 Algoma Hardwoods, Inc.

    .2 Baillargeon Doors, Inc.

    .3 DoorLam Manufacturing.

    .4 Eggers Industries.

    .5 JWS Manufacturing Inc.

    .6 Lambton Doors.

    .7 Marshfield Door Systems.

    .8 Mohawk Flush Doors, Inc.

    .9 Substitutions: in accordance with Section 01 25 00.

    2.2 Performance/Design Requirements – Fire Rating Requirements

    .1 Fire rated doors shall be fabricated, labelled and listed by an organization accredited byStandards Council of Canada in conformance with CAN/ULC-S104-10 and CAN/ULC-S105-09 for fire protection ratings as scheduled.

    .2 Install fire rated doors in accordance with NFPA 80-2010.

    2.3 General

    .1 Single-source manufacturing and fabrication responsibility: Engage a qualifiedManufacturer to assume undivided responsibility for wood doors specified in this section,including fabrication and finishing except where site finishing is specified.

    2.4 Fabrication – Door Construction

    .1 Performance duty level:

    .1 Doors shall meet the requirements of ANSI/WDMA I.S. 1A-13 for Heavy DutyPerformance Level unless otherwise indicated or scheduled.

    .2 Solid particleboard core, veneer faced, non fire rated and 20 minute fire rated wood doorconstruction to Architectural Woodwork Standards Manual, Section 9 and as follows:

    .1 Type PC-5, particle board core to ANSI A208.1-2009 LD-2 (minimum 529 kg/m3(33 lbs/ft3) density).

    8 of 75

  • Wellesley Community Centre Phase 2: Pool Addition Section 08 14 00City of Toronto Page 3Project No. 1311 February 15, 2017

    Flush Wood DoorsSection issued by Addendum No. 02

    .3 Solid fire resistant core; veneer faced, construction to Architectural Woodwork StandardsManual, Section 9 and as follows:

    .1 45, 60 and 90 minute rated doors; Type FD-5, non-combustible mineral core.

    .4 Bonding:

    .1 Bond stiles and rails to core; abrasive sand core assembly to achieve uniformthickness prior to lamination of door faces.

    .5 Panel edge types:

    .1 Wood veneer faced doors for transparent finish:

    .1 For vertical edges (stiles) and exposed horizontal edges (rails). (Exposedhorizontal edges are those edges that can be viewed from floors above.):

    .1 Edge Type A: Minimum 11 mm (7/16") thick solid hardwood, species tomatch face veneer, and referenced quality standard.

    .2 Inset solid wood edging shall have consistent moisture content as panelcore material, be glued securely, and calibrated with panel core thicknessprior to being laminated with wood veneer on both sides.

    .3 Non rated or 20 minute fire rated doors: Solid hardwood edge to belaminated to minimum 25.4 mm (1") structural composite lumber backer.

    .4 45, 60, or 90 minute fire rated doors: Solid hardwood edge to be laminatedto Tectonite or manufacturer’s standard fire rated material for fire rateddoors

    .2 For unexposed horizontal edges (rails):

    .1 Non rated or 20 minute fire rated doors: Minimum 25 mm (1") structuralcomposite lumber.

    .2 45, 60, or 90 minute fire rated doors: Tectonite or manufacturer’s standardfire rated material for fire rated doors.

    .3 Minimum 11 mm (7/16") thick, closed grain, solid hardwood edge.

    .1 Wood edge transparent finish to match face.

    .4 Non-rated or 20 minute fire rated doors: Solid hardwood edge to be laminatedto minimum 25.4 mm (1") structural composite lumber backer.

    .5 For 45, 60, or 90 minutes fire rated doors: Solid hardwood edge to belaminated to Tectonite or manufacturer’s standard fire rated material for firerated doors

    .6 Blocking:

    .1 Provide hardware blocking for doors as follows:

    .1 Non-rated or 20 minute fire rated doors: Structural composite lumber forhardware blocking.

    .2 45, 60, and 90 minute fire rated doors: Tectonite or manufacturer’s standardfire rated material for hardware blocking.

    9 of 75

  • Wellesley Community Centre Phase 2: Pool Addition Section 08 14 00City of Toronto Page 4Project No. 1311 February 15, 2017

    Flush Wood DoorsSection issued by Addendum No. 02

    .3 HB-1, minimum 125 mm (5") wide, full door width, top-rail blocking for closuredevices or flush bolts or for sliding door hardware.

    .4 HB-2, minimum 125 mm (5") wide, full door width, bottom-rail blocking fordoors with protection plates, concealed door seals, automatic bottoms, pivotsor floor bolts.

    .5 HB-4, minimum 125 mm (5") wide x 250 mm (10") high blocking for doors withmortise locks and pockets.

    .6 HB-5, minimum 125 mm (5") wide x 250 mm (10") high blocking for hinges.

    .7 HB-6, minimum 125 mm (5") wide, full door width, mid-rail blocking for exitdevices.

    .8 HB-7, minimum 125 mm (5") wide, full door height, for doors with continuoustype hinges.

    .7 Thickness:

    .1 45 mm (1-3/4") minimum unless otherwise indicated or scheduled.

    2.5 Veneer Faced Doors For Transparent Finish

    .1 Veneer face grade: Allowable wood veneer face grade characteristics shall comply withArchitectural Woodwork Standards, Edition 1, 2009 referenced grade and referencedstandards.

    .1 AA.

    .2 Veneer thickness: Minimum 1.02 mm (0.040") thick after sanding.

    .3 Veneer species: Maple.

    .4 Veneer cut: Quarter.

    .5 Veneer leaf matching: Book.

    .6 Veneer assembly matching: Balance.

    2.6 Accessories

    .1 Wood glass stops: Solid hardwood, species to match face finish, and referenced qualitystandard.

    .2 Finishing hardware: in accordance with Section 08 71 00.

    2.7 Fabrication

    .1 Fire rated doors shall be fabricated, labelled and listed by an organization accredited byStandards Council of Canada in conformance with CAN/ULC-S104-10 and CAN/ULC-S105-09 for fire protection ratings as scheduled.

    .2 Align and fit doors in frames with uniform clearances and bevels as indicated below; donot trim stiles and rails in excess of limits set by manufacturer or permitted for fire-rateddoors. Seal edges of doors, edges of cutouts, and mortises after fitting and machining.

    .1 Clearances: Refer to Part 3 for clearance tolerances.

    .2 Fit doors for automatic door bottoms.

    10 of 75

  • Wellesley Community Centre Phase 2: Pool Addition Section 08 14 00City of Toronto Page 5Project No. 1311 February 15, 2017

    Flush Wood DoorsSection issued by Addendum No. 02

    .3 Comply with NFPA 80-2010 for fire-rated doors.

    .4 Bevel non-fire-rated doors 3-1/2 degrees (1/8 inch in 2 inches) at lock and hingeedges.

    .5 Bevel fire-rated doors 3-1/2 degrees (1/8 inch in 2 inches) at lock edge; trim stilesand rails only to extent permitted by labelling agency.

    .3 Fabricate doors with hardware blocking as specified in Part 2 of this Section.

    .4 Factory machine doors for finish hardware that is not surface applied. Do not machine forsurface hardware. Locate hardware to comply with Door and Hardware Institute (DHI)“Recommended Locations for Architectural Hardware for Flush Wood Doors (latestedition). Comply with final reviewed hardware schedules, door and frame shop drawingsand hardware templates.

    .1 Coordinate with hardware mortises in metal frames to verify dimensions andalignment before factory machining.

    .2 Metal astragals: Factory machine astragals and formed-steel edges for hardwarefor pairs of fire rated doors.

    .5 Electrified hardware: Where electrically or electronically operated hardware is specifiedon the schedules or details or the final approved schedule and templates provided by thehardware supplier, doors with electrified devices shall be manufactured to include wireraceway in door panel to accommodate electrified devices, such as electric hinge, powertransfer units, electrified locks, electrified door closures and electrified exit devices.Construction of raceways shall provide a continuous conduit or channel between entryand exit points to accommodate wire installation after door manufacture.

    .6 Factory cut and trim openings.

    .1 Glazing: Factory install glazing in doors indicated to be factory finished.

    .7 Transom and side panels:

    .1 Fabricate matching panels with same construction, exposed surfaces, and finishas specified for associated doors. Finish bottom edges of transoms and top edgesof rabbeted doors same as door stiles.

    2.8 Factory Finishing

    .1 Finish work in factory in accordance with Architectural Woodwork Standards Manual,Section 9 and referenced quality standard.

    .2 Prior to finishing, handling marks or effects of exposure to moisture removed with athorough final sanding over surfaces of the exposed portions, using appropriate gritsandpaper, and shall be cleaned prior to applying sealer or finish. Sanding shall becompleted just prior to stain or finishing application.

    .3 Comply with requirements indicated below for finish system, staining, and sheen.

    .1 Sheen; Sheen range measurements in accordance with Architectural WoodworkStandards, Edition 2, 2014:

    .1 Satin.

    11 of 75

  • Wellesley Community Centre Phase 2: Pool Addition Section 08 14 00City of Toronto Page 6Project No. 1311 February 15, 2017

    Flush Wood DoorsSection issued by Addendum No. 02

    .2 Factory finish with transparent, Post Catalyzed Lacquer in accordance with theArchitectural Woodwork Standards, Edition 1, 2009, Section 5.

    .1 Transparent finish:

    .1 Clear (natural).

    .2 Stain: Stain colour as selected by Consultant.

    .4 Seal top and bottom door edges.

    PART 3 - EXECUTION

    3.1 Examination

    .1 Provide necessary grounds, bracing and strapping for fitting and adequate for securing ofthe work.

    .2 Cooperate with work of other sections to ensure fastenings set by others are provided andlocated, their work is installed to their specifications and that those responsible for backpriming are notified in sufficient time for them to schedule work.

    3.2 Installation - General

    .1 Execute installation and assembly at the Place of the Work using skilled forces undersupervision of a competent joinery foreperson.

    .2 Install work plumb, level and straight, and fasten it securely to backing to support itselfand anticipated superimposed loads.

    .3 Build into construction as indicated, or specified in other sections of this specification, orboth.

    .4 Adequately fasten units and secure in place with concealed fixings wherever possible.Include grounds and furring where required.

    3.3 Installation – Doors/Frames

    .1 Install fire rated doors in accordance with NFPA 80-2010.

    .2 Install wood doors after finishing of walls.

    .3 Align and fit doors in frames with uniform clearances as indicated below; do not trim stilesand rails in excess of limits set by manufacturer or permitted for fire-rated doors. Machinedoors for hardware. Seal edges of doors, edges of cutouts, and mortises after fitting andmachining.

    .1 Clearances:

    .1 Provide 3.2 mm (1/8") maximum clearance between door and frame at heads,jambs, and between pairs of doors.

    .2 Provide minimum 3.2 mm (1/8") maximum clearance from bottom of door totop of decorative floor finish or covering unless otherwise indicated..

    .3 Where threshold is shown or scheduled, 6.4 mm (1/4") minimum from bottomof door to top of threshold unless otherwise indicated and a maximum of12.7 mm (1/2").

    12 of 75

  • Wellesley Community Centre Phase 2: Pool Addition Section 08 14 00City of Toronto Page 7Project No. 1311 February 15, 2017

    Flush Wood DoorsSection issued by Addendum No. 02

    .2 Comply with NFPA 80 for fire-rated doors.

    .4 Seal top and bottom edges of wood doors if they are cut to fit, in accordance with doormanufacturer’s warranty requirements.

    .5 Pilot drill screw and bolt holes.

    .6 Coordinate installation of doors with installation of frames specified in Section 08 11 13,and hardware specified in Section 08 71 00.

    3.4 Installation - Finishing Hardware

    .1 Install finishing hardware in accordance with Section 08 71 00.

    3.5 Adjusting and Cleaning

    .1 Adjust doors to swing freely, smoothly and easily, to remain stationary at any point, toclose evenly and tightly against stops without binding, and to latch positively when doorsare closed with moderate force.

    .2 Adjust hardware so that latches and locks operate smoothly and without binding, andclosers act positively with the least possible resistance in use. Lubricate hardware ifrequired by Supplier’s instructions.

    .3 Ensure that doors equipped with closers operate to close doors firmly against anticipatedwind and building air pressure, and to enable doors to be readily opened as suitable forfunction, location and traffic.

    .4 Clean hardware after installation in accordance with Supplier’s instructions.

    END OF SECTION

    13 of 75

  • Page 12/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Wellesley Community CentrePhase 2 - Pool Addition

    ArchitectMacLennan Jaunkalns Miller Architects

    425 Adelaide Street WestLevel 6

    Toronto, OntarioM5V 3C1

    Tel: 416-593-6796

    CoordinatorMark Di Plama

    Tel: 905-940-8358 Ext: 205Fax: 905-940-8362

    Email: [email protected]

    Consultant-----------------

    Brian Hughes Tel: 647-502-7955Fax: 905-940-8362

    E-Mail: [email protected]

    Submittal Date: February 10, 2017

    14 of 75

  • Page 22/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Openings Schedule

    HardwareGroup Qty

    OpeningNumber(s) Location 1

    To/From Location 2 Hand

    DoorType

    NominalWidth

    NominalHeight

    DoorThickness

    DoorMat'l

    FrameMat'l Label

    001 1 B61 CORRIDOR B60 FROM STORAGE B61 LHR/RHRA D2/F02 900, 900 2350 45 HM HM

    002 1 B62 STORAGE B61 FROM HOISTWAY ACCESS B62 LHR/RHRA D2/F02 900, 900 2350 45 HM HM 45 MIN

    003 1 B63 CORRIDOR B60 FROM MECHANICAL B63 LHR/RHRA D2/F02 900, 900 2150 45 HM HM 45 MIN

    004 1 B68 FILTRATION RM B65 TO GROUND HEAT EXCHANGE B68 RH D1/F01 1000 2350 45 HM HM 45 MIN

    005 1 STA-O STAIR FROM CORRIDOR B60 RHR D3/F01 1000 2350 45 HM HM 45 MIN

    006 1 060A ATHLETIC CORRIDOR 031 TO ENTRY 060 SLIDER D11 3020 3000 WD -

    007 1 060B ENTRY 060 TO UNIVERSAL CHANGE ROOM 064 SLIDER D5 2134 2352 AL AL

    008 1 060C ENTRY 060 TO UNIVERSAL CHANGE ROOM 077 SLIDER D5 2134 2352 AL AL

    009 1 061B ENTRY 060 TO RECEPTION 061 LH D1/F01 1000 2350 45 HM HM

    010 1 062 STAFF KITCHEN 062 TO AQUATIC STAFF 063 LH D1/F01 1000 2350 45 HM HM

    011 1 062A STAFF KITCHEN 061 FROM ELECT CLOSET 062A LHR/RHRA D2/F02 900, 900 2350 45 HM HM

    012 1 063 POOL HALL 072 TO AQUATIC STAFF 063 RH D4/F05 1000 2350 45 AL AL

    012A 1 064A EXIST ATHLETIC CORRIDOR 031 FROM UNIVERSAL CHANGE ROOM B 064 RHR D6 1050 2245 45 AL AL

    012B 1 064B UNIVERSAL CHANGE ROOM B 064 TO SHOWER 069 O/H D10 1210 2400 45 AL AL

    013 1 065 UNIVERSAL CHANGE ROOM 064 TO UNIVERSAL TOILET/CHANGE 065 RH D1/F01 1000 2350 45 HM HM

    014 1 067 CORRIDOR 066 FROM ACCESSIBLE W/C 067 LHR D1/F01 950 2350 45 HM HM

    015 1 068 CORRIDOR 066 FROM ACCESSIBLE W/C 068 LHR D1/F01 950 2350 45 HM HM

    016 1 069A UNIVERSAL CHANGE ROOM 064 FROM SHOWER 069 O/H D10 1200 3200 AL -

    017 1 069 POOL HALL 072 FROM SHOWER 069 O/H D10 1610 3200 AL -

    018 1 070 EXTERIOR TO CHOLRINE STORAGE 070 RH D1/F01 900 2350 45 HM HM

    019 1 071 EXTERIOR FROM HOISTWAY SHAFT 071 LHR/RHRA D2/F02 900, 900 2350 45 HM HM

    020 1 072 ENTRY 006 FROM VIEW IN AREA 072 RHR D4/F05 900, 900 2650 45 AL AL

    020A 1 072B POOL HALL FROM STAIR B RH 915 1800 13 GL -

    021 1 073A POOL HALL 072 FROM POOL STORAGE 073 RHR D1/F01 1210 2150 45 HM HM

    022 1 073B POOL HALL 072 FROM POOL STORAGE 073 LHR D1/F01 1210 2150 45 HM HM

    023 1 075 POOL HALL 072 FROM POOL STORAGE 075 RHR D2A/F06 800 2350 45 AL AL

    024 1 076 POOL HALL 072 TO STEAM ROOM 076 RH D4/F05 1000 2350 45 AL AL

    024A 1 077A EXIST ATHLETIC CORRIDOR 031 FROM UNIVERSAL CHANGE ROOM A 077 LHR D6 1050 2845 45 AL AL

    024B 1 077B UNIVERSAL CHANGE ROOM A 077 TO SHOWER 082 O/H D-10 1210 2400 45 AL -

    025 1 078 UNIVERSAL CHANGE ROOM 077 TO UNIVERSAL TOILET/CHANGE 078 LH D1/F01 1000 2150 45 HM HM

    026 1 080 CORRIDOR 079 FROM ACCESSIBLE W/C 080 RHR D1/F01 950 2350 45 HM HM

    027 1 081 CORRIDOR 079 FROM ACCESSIBLE W/C 081 RHR D1/F01 950 2350 45 HM HM

    028 1 082A UNIVERSAL CHANGE ROOM 077 FROM SHOWER 082 O/H D10 1200 2400 AL -

    029 1 082B POOL HALL 072 FROM SHOWER 082 O/H D10 1550 3200 AL -

    030 1 083 NEW VESTIBULE EXIT 083 FROM POOL HALL 072 LHR D4/F05 1000 2650 45 AL AL

    031 1 083B EXTERIOR FROM NEW VESTIBULE EXIT 083 LHR D3A/F04 1048 2660 45 WD HM

    032 1 ST-A1 STAIR A1 FROM POOL HALL 072 RHR D3 1000 2350 45 HM HM 45 MIN

    033 1 ST-A1B EXTERIOR FROM STAIR A1 RHR D1 1000 2350 45 HM HM

    034 1 160A CORRIDOR 160 FROM MECHANICAL LHR D2A/F03 1000 2250 45 HM HM

    035 1 160B MECHANCIAL TO GREEN ROOF RH D1/F01 1000 2350 45 HM HM

    036 1 161 CORRIDOR 160 TO ELECTRICAL 161 RH D2A/F03 1000 2250 45 HM HM 45 MIN

    037 1 162 CORRIDOR 160 FROM OFFICE 162 LHR D2A/F05 1000 2250 45 WD AL

    038 1 163 OFFICE 162 TO LAN ROOM 163 LH D1/F01 1000 2350 45 HM HM

    039 1 164 CORRIDOR 160 FROM MULTI-PURPOSE 164 LHR D2A/F05 1000 2250 45 WD AL

    039A 1 164A MULTI-PURPOSE 164 FROM STORAGE 164A RHR D2A/F3 1000 2250 45 HM HM

    039B 1 165 2ND FLOOR CORRIDOR 160 TO UNISEX WC 165 RH D2A/F3 1000 2250 45 WD WD

    15 of 75

  • Page 32/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    HardwareGroup Qty

    OpeningNumber(s) Location 1

    To/From Location 2 Hand

    DoorType

    NominalWidth

    NominalHeight

    DoorThickness

    DoorMat'l

    FrameMat'l Label

    040 1 165A MULTI-PURPOSE 164 FROM STORAGE 165 LHR/RHRA D2A/F04 900, 900 2250 45 HM HM

    041 1 165B MULTI-PURPOSE 166 FROM STORAGE 163 LHR/RHRA D2B/F04 900, 900 2350 45 WD HM

    042 1 166A CORRIDOR 160 FROM MULTI-PURPOSE 166 LHR D2A/F05 1000 2250 45 WD AL

    043 1 166B CORRIDOR 160 FROM MULTI-PURPOSE 166 LHR D2A/F05 1000 2250 45 WD AL

    044 1 167A MULTI-PURPOSE 166 FROM STORAGE 167 LHR/RHRA D2B/F04 900, 900 2250 45 HM HM

    045 1 168 CORRIDOR 160 TO ACCESSIBLE W/C 168 RH D2A/F03 1000 2250 45 HM HM

    046 1 168A 1 - -

    047 1 ST-A2 STAIR A2 FROM CORRIDOR 160 LHR D3/F05 900 2250 45 HM HM 45 MIN

    16 of 75

  • Page 42/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Hardware Schedule

    Heading #001

    1 Pair of doors B61, CORRIDOR B60 FROM STORAGE B61 LHR/RHRA

    Type: D2/F02, 900, 900 x 2350 x 45 - HM DR x HM FR

    8 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Lockset L9080HD 07B 630 RHR 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System2 Flush Bolt GSH 401-12" C26D C26D1 Surface Closer 4050 PA AL DEL AL2 Kick Plate GSH 80A C32D (200 X 876) RC TM C32D2 Wall Door Stop GSH 240B C32D C32D

    Heading #002

    1 Pair of doors B62, STORAGE B61 FROM HOISTWAY ACCESS B62 LHR/RHRA

    Type: D2/F02, 900, 900 x 2350 x 45 - HM DR x HM FR - 45 MIN

    8 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Latchset L9010 07B 630 RHR 6302 Flush Bolt FB458-24 ULC C26D C26D1 Surface Closer 4050 PA AL DEL AL1 Overhead Door Stop 904S C32D (110 Deg.) C32D

    (Inactive leaf)2 Kick Plate GSH 80A C32D (200 X 876) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D

    (Active leaf)

    17 of 75

  • Page 52/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #003

    1 Pair of doors B63, CORRIDOR B60 FROM MECHANICAL B63 LHR/RHRA

    Type: D2/F02, 900, 900 x 2150 x 45 - HM DR x HM FR - 45 MIN

    6 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Lockset L9080HD 07B 630 RHR 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System2 Flush Bolt FB458-24 ULC C26D C26D1 Surface Closer 4050 PA AL DEL AL1 Overhead Door Stop 904S C32D (110 Deg.) C32D

    (Inactive leaf)2 Kick Plate GSH 80A C32D (200 X 876) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D

    (Active leaf)

    Heading #004

    1 Single door B68, FILTRATION RM B65 TO GROUND HEAT EXCHANGE B68 RH

    Type: D1/F01, 1000 x 2350 x 45 - HM DR x HM FR - 45 MIN

    4 Standard Hinge STSCB1399 114 X 101 NRP 32D 32D1 Lockset L9080HD 07B 630 RH 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Surface Closer 4050 REG AL AL1 Kick Plate GSH 80A C32D (200 X 965) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D

    18 of 75

  • Page 62/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #005

    1 Single door STA-O, STAIR FROM CORRIDOR B60 RHR

    Type: D3/F01, 1000 x 2350 x 45 - HM DR x HM FR - 45 MIN

    4 Standard Hinge STSCB1399 114 X 101 NRP 32D 32D1 Exit Device 98-L-NL-F C26D 996L-NL-R C26D RHR #07 Lever 1000 x 2350 Door C26D/C26D1 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Rim Cylinder 80-159 6261 Surface Closer 4050 REG AL AL1 Kick Plate GSH 80A C32D (200 X 965) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D1 Door Contact 1078-1 BRN BRN

    Heading #006

    1 Single door 060A, ATHLETIC CORRIDOR 031 TO ENTRY 060 SLIDER

    Type: D11, 3020 x 3000 x __ - WD DR x - FR

    DOOR DELETED

    Heading #007

    1 Single door 060B, ENTRY 060 TO UNIVERSAL CHANGE ROOM 064 SLIDER

    Type: D5, 2134 x 2352 x __ - AL DR x AL FR

    COMPLETE BY MANUFACTURER

    Heading #008

    1 Single door 060C, ENTRY 060 TO UNIVERSAL CHANGE ROOM 077 SLIDER

    Type: D5, 2134 x 2352 x __ - AL DR x AL FR

    COMPLETE BY MANUFACTURER

    19 of 75

  • Page 72/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #009

    1 Single door 061B, ENTRY 060 TO RECEPTION 061 LH

    Type: D1/F01, 1000 x 2350 x 45 - HM DR x HM FR

    3 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Lockset L9070HD 07B 630 LH 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Surface Closer 4050 PA AL DEL AL1 Kick Plate GSH 80A C32D (200 X 965) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D1 Door Contact 1078-1 BRN BRN

    Heading #010

    1 Single door 062, STAFF KITCHEN 062 TO AQUATIC STAFF 063 LH

    Type: D1/F01, 1000 x 2350 x 45 - HM DR x HM FR

    3 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Lockset L9070HD 07B 630 LH 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Surface Closer 4050 PA AL DEL AL1 Kick Plate GSH 80A C32D (200 X 965) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D

    Heading #011

    1 Pair of doors 062A, STAFF KITCHEN 061 FROM ELECT CLOSET 062A LHR/RHRA

    Type: D2/F02, 900, 900 x 2350 x 45 - HM DR x HM FR

    8 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Lockset L9080HD 07B 630 RHR 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System2 Flush Bolt FB458-24 ULC C26D C26D2 Overhead Door Stop 452S C32D (110 Deg,) C32D

    20 of 75

  • Page 82/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #012

    1 Single door 063, POOL HALL 072 TO AQUATIC STAFF 063 RH

    Type: D4/F05, 1000 x 2350 x 45 - AL DR x AL FR

    1 Continuous Hinge SL11 CL HD x 2350 CL1 Set Door Pull GSH 1180-2 BTB C32D C32D1 Dead Lock MS1850S-210-628 - RH 6281 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Mortise Cylinder 80-113 6261 Thumb Turn Cylinder 4066-01-130 1301 Surface Closer 4050 REG AL AL1 Mounting Plate 4050-18 AL AL1 Wall Door Stop GSH 240B C32D C32D1 Door Contact 1078-1 BRN BRN

    Heading #012A

    1 Single door 064A, EXIST ATHLETIC CORRIDOR 031 FROM UNIVERSAL CHANGE ROOM B 064 RHR

    Type: D6, 1050 x 2245 x 45 - AL DR x AL FR

    1 Continuous Hinge SL40 BLACK HD x 2220 BLACK1 Exit Device 35A-EO C26D RHR 4' Bar 1050 x 2245 Door C26D1 Door Closer 4050 S CUSH x 61 Spacer AL AL

    NOTE:HARDWARE TO BE REVIEWED AND CONFIRM.

    Heading #012B

    1 Single door 064B, UNIVERSAL CHANGE ROOM B 064 TO SHOWER 069 O/H

    Type: D10, 1210 x 2400 x 45 - AL DR x AL FR

    OVERHEAD DOOR

    ALL HARDWARE COMPLETE BY DOOR SUPPLIER

    21 of 75

  • Page 92/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #013

    1 Single door 065, UNIVERSAL CHANGE ROOM 064 TO UNIVERSAL TOILET/CHANGE 065 RH

    Type: D1/F01, 1000 x 2350 x 45 - HM DR x HM FR

    3 Standard Hinge STSCB1399 114 X 101 NRP 32D 32D1 Lockset L9080HD 07B 630 RH 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Electric Strike 4500C-FS-24VDC-630-LBM 630-LBM1 Auto Door Operator 8500 628 (Pull Side) 6282 Actuator 6R3 630 6301 Indicator CM-AF5001 Push-to-Lock Button CM-400/81 Relay CX-EMF-21 LED Annunciator CM-AF501501 Assistance Requied Light CM-AF140501 Emergency Sign CM-SE21A1 Emergency Strip Nexgen Emerg Strip x 610mm1 Relay TA-2871 - For Emergency Strip1 Power Supply CX-PS313 V31 Kick Plate GSH 80A C32D (200 X 965) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D

    Heading #014

    1 Single door 067, CORRIDOR 066 FROM ACCESSIBLE W/C 067 LHR

    Type: D1/F01, 950 x 2350 x 45 - HM DR x HM FR

    4 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Privacy Set L9040 07B 630 LHR 6301 Overhead Door Stop 905S C32D C32D1 Kick Plate GSH 80A C32D (200 x 912) RCTM C32D

    22 of 75

  • Page 102/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #015

    1 Single door 068, CORRIDOR 066 FROM ACCESSIBLE W/C 068 LHR

    Type: D1/F01, 950 x 2350 x 45 - HM DR x HM FR

    4 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Privacy Set L9040 07B 630 LHR 6301 Overhead Door Stop 905S C32D C32D1 Kick Plate GSH 80A C32D (200 x 912) RCTM C32D

    Heading #016

    1 Single door 069A, UNIVERSAL CHANGE ROOM 064 FROM SHOWER 069 O/H

    Type: D10, 1200 x 3200 x __ - AL DR x - FR

    DOOR DELETED

    Heading #017

    1 Single door 069, POOL HALL 072 FROM SHOWER 069 O/H

    Type: D10, 1610 x 3200 x __ - AL DR x - FR

    OVERHEAD DOOR

    COMPELTE BY DOOR SUPPLIER

    23 of 75

  • Page 112/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #018

    1 Single door 070, EXTERIOR TO CHOLRINE STORAGE 070 RH

    Type: D1/F01, 900 x 2350 x 45 - HM DR x HM FR

    4 Standard Hinge STSCB1399 114 X 101 NRP 32D 32D1 Lockset L9080HD 07B 630 RH 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Surface Closer 4050 REG AL AL1 Floor Door Stop GSH 209 C26D C26D1 Door Sweep W-24S-CA x 900 CA1 Threshold CT-45 x 9001 Weatherstripping W-20S-CA 1 x 900 + 2 x 2350 CA1 Door Contact 1078-1 BRN BRN

    Heading #019

    1 Pair of doors 071, EXTERIOR FROM HOISTWAY SHAFT 071 LHR/RHRA

    Type: D2/F02, 900, 900 x 2350 x 45 - HM DR x HM FR

    8 Standard Hinge STSCB1399 114 X 101 NRP 32D 32D1 Lockset L9080HD 07B 630 RHR 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System2 Flush Bolt GSH 401-12" C26D C26D1 Surface Closer 4050 S CUSH AL AL2 Kick Plate GSH 80A C32D (200 X 876) RC TM C32D1 Threshold CT-45 x 18001 Weatherstripping W-20S-CA 1 @ 1800 + 2 @ 2350 CA2 Door Sweep W-24S-CA x 900 CA1 Astragal W-5 x 23502 Door Contact 1078-1 BRN BRN

    24 of 75

  • Page 122/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #020

    1 Single door 072, ENTRY 006 FROM VIEW IN AREA 072 RHR

    Type: D4/F05, 900, 900 x 2650 x 45 - AL DR x AL FR

    2 Continuous Hinge SL11 CL HD x 26251 Dead Lock MS1850S-210-628 6281 Thumb Turn Cylinder 4066-01-130 1301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Mortise Cylinder 80-113 6261 Set Door Pull GSH 1180-2 BTB C32D C32D2 Surface Closer 4050 PA AL DEL AL1 Flush Bolts Flush Bolts - By Door Supplier2 Mounting Plate 4050-18TJ AL AL1 Wall Door Stop GSH 240B C32D C32D2 Door Contact 1078-1 BRN BRN

    Heading #020A

    1 Elevation 072B, POOL HALL FROM STAIR B RH

    915 x 1800 x 13 - GL DR x - FR

    1 Hinge Tensor 812.520.1141 Patch Lock S104 B C32D C32D1 Mortise Cylinder 80-131 x B520-296 6261 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Strike GSH Custom ASA Strike w/ Stop

    Heading #021

    1 Single door 073A, POOL HALL 072 FROM POOL STORAGE 073 RHR

    Type: D1/F01, 1210 x 2150 x 45 - HM DR x HM FR

    1 Continuous Hinge SL11 CL HD x 21251 Lockset L9080HD 07B 630 RHR 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Overhead Door Stop 906S C32D C32D

    25 of 75

  • Page 132/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #022

    1 Single door 073B, POOL HALL 072 FROM POOL STORAGE 073 LHR

    Type: D1/F01, 1210 x 2150 x 45 - HM DR x HM FR

    1 Continuous Hinge SL11 CL HD x 21251 Lockset L9080HD 07B 630 LHR 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Overhead Door Stop 906S C32D C32D

    Heading #023

    1 Single door 075, POOL HALL 072 FROM POOL STORAGE 075 RHR

    Type: D2A/F06, 800 x 2350 x 45 - AL DR x AL FR

    1 Continuous Hinge SL11 CL HD x 21251 Lockset L9080HD 07B 630 RHR 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Overhead Door Stop 905S C32D C32D

    Heading #024

    1 Single door 076, POOL HALL 072 TO STEAM ROOM 076 RH

    Type: D4/F05, 1000 x 2350 x 45 - AL DR x AL FR

    1 Continuous Hinge SL11 CL HD x 2350 CL1 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Mortise Cylinder 80-113 6261 Dead Lock MS1850S-210-628 - RH 6281 THUMBTURN CYLINDER 09-900 X AR CAM 626 6261 Set Door Pulls GSH 165F x 165F Wood BTB Oak OAK1 Roller Latch GSH 404H S C32D S C32D

    NOTE:WEATHER SEAL COMPLETE BY DOOR MANUFACTURER

    26 of 75

  • Page 142/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #024A

    1 Single door 077A, EXIST ATHLETIC CORRIDOR 031 FROM UNIVERSAL CHANGE ROOM A 077 LHR

    Type: D6, 1050 x 2845 x 45 - AL DR x AL FR

    1 Continuous Hinge SL40 BLACK HD x 2820 BLACK1 Exit Device 35A-EO C26D LHR 4' Bar 1050 x 2845 Door C26D1 Door Closer 4050 S CUSH x 61 Spacer AL AL

    NOTE:HARDWARE TO BE REVIEWED AND CONFIRM.

    Heading #024B

    1 Single door 077B, UNIVERSAL CHANGE ROOM A 077 TO SHOWER 082 O/H

    Type: D-10, 1210 x 2400 x 45 - AL DR x - FR

    OVERHEAD DOOR

    ALL HARDWARE COMPLETE BY DOOR SUPPLIER

    27 of 75

  • Page 152/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #025

    1 Single door 078, UNIVERSAL CHANGE ROOM 077 TO UNIVERSAL TOILET/CHANGE 078 LH

    Type: D1/F01, 1000 x 2150 x 45 - HM DR x HM FR

    3 Standard Hinge STSCB1399 114 X 101 NRP 32D 32D1 Lockset L9080HD 07B 630 LH 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Electric Strike 4500C-FS-24VDC-630-LBM 630-LBM1 Auto Door Operator 8500 628 (Pull Side) 6282 Actuator 6R3 630 6301 Indicator CM-AF5001 Push-to-Lock Button CM-400/81 Relay CX-EMF-21 LED Annunciator CM-AF501501 Assistance Requied Light CM-AF140501 Emergency Sign CM-SE21A1 Emergency Strip Nexgen Emerg Strip x 610mm1 Relay TA-2871 - For Emergency Strip1 Power Supply CX-PS313 V31 Kick Plate GSH 80A C32D (200 X 965) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D

    Heading #026

    1 Single door 080, CORRIDOR 079 FROM ACCESSIBLE W/C 080 RHR

    Type: D1/F01, 950 x 2350 x 45 - HM DR x HM FR

    4 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Privacy Set L9040 07B 630 RHR 6301 Overhead Door Stop 905S C32D C32D1 Kick Plate GSH 80A C32D (200 x 912) RCTM C32D

    28 of 75

  • Page 162/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #027

    1 Single door 081, CORRIDOR 079 FROM ACCESSIBLE W/C 081 RHR

    Type: D1/F01, 950 x 2350 x 45 - HM DR x HM FR

    4 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Privacy Set L9040 07B 630 RHR 6301 Overhead Door Stop 905S C32D C32D1 Kick Plate GSH 80A C32D (200 x 912) RCTM C32D

    Heading #028

    1 Single door 082A, UNIVERSAL CHANGE ROOM 077 FROM SHOWER 082 O/H

    Type: D10, 1200 x 2400 x __ - AL DR x - FR

    DOOR DELETED

    Heading #029

    1 Single door 082B, POOL HALL 072 FROM SHOWER 082 O/H

    Type: D10, 1550 x 3200 x __ - AL DR x - FR

    OVERHEAD DOOR

    COMPELTE BY DOOR SUPPLIER

    29 of 75

  • Page 172/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #030

    1 Single door 083, NEW VESTIBULE EXIT 083 FROM POOL HALL 072 LHR

    Type: D4/F05, 1000 x 2650 x 45 - AL DR x AL FR

    1 Continuous Hinge SL11 CL HD x 26251 Exit Device 98EO C32D x 98ALK - LHR C32D1 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Mortise Cylinder 80-132 6261 Surface Closer 4050 REG AL AL1 Mounting Plate 4050-18TJ AL AL1 Floor Door Stop GSH 209 C26D C26D1 Door Contact 1078-1 BRN BRN

    NOTE:ALARM KIT BUILT INTO EXIT DEVICE.

    Heading #031

    1 Single door 083B, EXTERIOR FROM NEW VESTIBULE EXIT 083 LHR

    Type: D3A/F04, 1048 x 2660 x 45 - WD DR x HM FR

    1 Continuous Hinge SL11 CL HD x 26251 Exit Device 98EO C32D LHR 1048 x 2660 Door C32D1 Surface Closer 4050 TJ AL AL1 Drop Plate 4050-18G AL AL1 Overhead Door Stop 905S C32D C32D1 Threshold CT-45 x 10001 Door Sweep W-24S-CA x 1000 CA1 Door Contact 1078-1 BRN BRN

    BALANCE OF WEATHER SEAL BY DOOR SUPPLIER

    30 of 75

  • Page 182/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #032

    1 Single door ST-A1, STAIR A1 FROM POOL HALL 072 RHR

    Type: D3, 1000 x 2350 x 45 - HM DR x HM FR - 45 MIN

    4 Standard Hinge STSCB1399 114 X 101 NRP 32D 32D2 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Rim Cylinder 80-159 6261 Mortise Cylinder 80-132 6261 Exit Device 98L-F C32D 996L-NL ALK C26D #07 Lever - RHR C26D/C32D1 Surface Closer 4050 REG AL AL1 Kick Plate GSH 80A C32D (200 X 965) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D1 Door Sweep W-24S-CA x 900 CA1 Door Contact 1078-1 BRN BRN

    NOTE:ALARM KIT BUILT INTO EXIT DEVICE.

    Heading #033

    1 Single door ST-A1B, EXTERIOR FROM STAIR A1 RHR

    Type: D1, 1000 x 2350 x 45 - HM DR x HM FR

    4 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Exit Device 98EO C32D RHR 1000 x 2350 Door C32D1 Surface Closer 4050 S CUSH AL AL1 Kick Plate GSH 80A C32D (200 X 965) RC TM C32D1 Threshold CT-45 x 9001 Weatherstripping W-20S-CA 1 x 900 + 2 x 2350 CA1 Door Sweep W-24S-CA x 900 CA1 Door Contact 1078-1 BRN BRN

    31 of 75

  • Page 192/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #034

    1 Single door 160A, CORRIDOR 160 FROM MECHANICAL LHR

    Type: D2A/F03, 1000 x 2250 x 45 - HM DR x HM FR

    4 Standard Hinge STSCB1399 114 X 101 NRP 32D 32D1 Lockset L9080HD 07B 630 LHR 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Surface Closer 1450 S CUSH AL AL1 Wall Door Stop GSH 240B C32D C32D1 Threshold CT-45 x 10001 Door Sweep W-24S-CA x 1000 CA1 Weatherstripping W-20S-CA 1 x 1000 + 2 x 2350 CA1 Door Contact 1078-1 BRN BRN

    Heading #035

    1 Single door 160B, MECHANCIAL TO GREEN ROOF RH

    Type: D1/F01, 1000 x 2350 x 45 - HM DR x HM FR

    4 Standard Hinge STSCB1399 114 X 101 NRP 32D 32D1 Lockset L9080HD 07B 630 RH 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Surface Closer 4050 S CUSH AL AL1 Threshold CT-45 x 1000

    Heading #036

    1 Single door 161, CORRIDOR 160 TO ELECTRICAL 161 RH

    Type: D2A/F03, 1000 x 2250 x 45 - HM DR x HM FR - 45 MIN

    4 Standard Hinge STSCB1399 114 X 101 NRP 32D 32D1 Lockset L9080HD 07B 630 RH 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Surface Closer 1450 Rw/PA AL AL1 Kick Plate GSH 80A C32D (200 X 965) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D

    32 of 75

  • Page 202/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #037

    1 Single door 162, CORRIDOR 160 FROM OFFICE 162 LHR

    Type: D2A/F05, 1000 x 2250 x 45 - WD DR x AL FR

    3 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Lockset L9070HD 07B 630 LHR 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Surface Closer 4050 TJ DEL AL AL1 Kick Plate GSH 80A C32D (200 X 965) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D

    Heading #038

    1 Single door 163, OFFICE 162 TO LAN ROOM 163 LH

    Type: D1/F01, 1000 x 2350 x 45 - HM DR x HM FR

    4 Standard Hinge STSCB1399 114 X 101 NRP 32D 32D1 Lockset L9080HD 07B 630 LH 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Wall Door Stop GSH 240B C32D C32D1 Door Contact 1078-1 BRN BRN

    Heading #039

    1 Single door 164, CORRIDOR 160 FROM MULTI-PURPOSE 164 LHR

    Type: D2A/F05, 1000 x 2250 x 45 - WD DR x AL FR

    3 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Lockset L9070HD 07B 630 LHR 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Surface Closer 4050 TJ DEL AL AL1 Kick Plate GSH 80A C32D (200 X 965) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D

    33 of 75

  • Page 212/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #039A

    1 Single door 164A, MULTI-PURPOSE 164 FROM STORAGE 164A RHR

    Type: D2A/F3, 1000 x 2250 x 45 - HM DR x HM FR

    3 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Lockset L9070HD 07B 630 RHR 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Wall Door Stop GSH 240B C32D C32D

    Heading #039B

    1 Single door 165, 2ND FLOOR CORRIDOR 160 TO UNISEX WC 165 RH

    Type: D2A/F3, 1000 x 2250 x 45 - WD DR x WD FR

    4 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Privacy Set L9040 07B 630 RH 6301 Kick Plate GSH 80A C32D (200 X 965) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D

    Heading #040

    1 Pair of doors 165A, MULTI-PURPOSE 164 FROM STORAGE 165 LHR/RHRA

    Type: D2A/F04, 900, 900 x 2250 x 45 - HM DR x HM FR

    DOOR DELETED

    Heading #041

    1 Pair of doors 165B, MULTI-PURPOSE 166 FROM STORAGE 163 LHR/RHRA

    Type: D2B/F04, 900, 900 x 2350 x 45 - WD DR x HM FR

    DOOR DELETED

    34 of 75

  • Page 222/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #042

    1 Single door 166A, CORRIDOR 160 FROM MULTI-PURPOSE 166 LHR

    Type: D2A/F05, 1000 x 2250 x 45 - WD DR x AL FR

    3 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Lockset L9070HD 07B 630 LHR 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Surface Closer 4050 TJ DEL AL AL1 Kick Plate GSH 80A C32D (200 X 965) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D

    Heading #043

    1 Single door 166B, CORRIDOR 160 FROM MULTI-PURPOSE 166 LHR

    Type: D2A/F05, 1000 x 2250 x 45 - WD DR x AL FR

    3 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Lockset L9070HD 07B 630 LHR 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Surface Closer 4050 TJ DEL AL AL1 Kick Plate GSH 80A C32D (200 X 965) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D

    Heading #044

    1 Pair of doors 167A, MULTI-PURPOSE 166 FROM STORAGE 167 LHR/RHRA

    Type: D2B/F04, 900, 900 x 2250 x 45 - HM DR x HM FR

    8 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Lockset L9070HD 07B 630 RHR 6301 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Surface Bolt GSH 72 x 24" C26D C26D2 Overhead Door Stop 454S C32D (90 Deg.) C32D

    35 of 75

  • Page 232/10/17

    Upper Canada Specialty Hardware7100 Warden Ave.Unit 1Markham, Ontario, L3R 8B5

    Wellesley Community CentrePhase 2 - Pool Addition

    Submittal Date: February 10, 2017

    Heading #045

    1 Single door 168, CORRIDOR 160 TO ACCESSIBLE W/C 168 RH

    Type: D2A/F03, 1000 x 2250 x 45 - HM DR x HM FR

    4 Standard Hinge STSCB1391 114 x 101 NRP 32D 32D1 Privacy Set L9040 07B 630 RH 6301 Kick Plate GSH 80A C32D (200 X 965) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D

    Heading #046

    1 Single door 168A

    1 x __ x __ - - DR x - FR

    DELETE - RESERVE HEADING FOR FUTURE USE

    Heading #047

    1 Single door ST-A2, STAIR A2 FROM CORRIDOR 160 LHR

    Type: D3/F05, 900 x 2250 x 45 - HM DR x HM FR - 45 MIN

    4 Standard Hinge STSCB1399 114 X 101 NRP 32D 32D1 Exit Device 98-L-NL-F C26D 996L-NL-R C26D LHR #07 Lever 900 x 2250 Door C26D/C26D1 Rim Cylinder 80-159 6261 Cylinder Cyl. Schlage Everest B123 Keyed to Exist. MK System1 Surface Closer 4050 REG AL AL1 Kick Plate GSH 80A C32D (200 X 876) RC TM C32D1 Wall Door Stop GSH 240B C32D C32D1 Weatherstripping W-22-BL x 5600 BL1 Door Contact 1078-1 BRN BRN

    36 of 75

  • Wellesley Community Centre Phase 2 – Pool Addition Addendum 02MacLennan Jaunkalns Miller Architects Page 1Project No. 1311 February 15, 2017

    Architectural Drawings ADD2

    3a. LANDSCAPE DRAWING REVISIONS + CLARIFICATIONS

    Drawing L100-A LANDSCAPE REMOVALS PLAN - A.1

    a) ADD the following note to the drawing legend: Where sub—base is to be retained under the removal of paving contractor shall verify depth of sub-base materials to comply with details 6, 7, & 8/L500. (No sketch issued)

    b) ADD the following note to the drawing legend: Existing pedestrian concrete to remain damaged by construction activities to be repaired or replaced in kind. (No sketch issued)

    c) ADD the following note to the drawing legend: Removals plan to be read in conjunction with L101A & B. (No sketch issued)

    d) DELETE duplicate note.REFER TO ADD2-010

    Drawing L100-B LANDSCAPE REMOVALS PLAN - B.1

    a) Refer comments .1 & .2 above.

    b) ADD hatch and note.REFER TO ADD2-010

    Drawing L101-A LAYOUT AND MATERIALS PLAN – A & Drawing L101-B LAYOUT AND MATERIALS PLAN

    .1 L101-A, L101-B

    a) ADD notes.REFER TO ADD2-011

    Drawing L102-B GRADING PLAN – B .1

    a) REVISE hatch to show existing concrete.b) ADD markers showing where new meets existing.c) DELETE marker showing where new meets existing.REFER TO ADD2-012

    Drawing L500 LANDSCAPE DETAILS .8/L500

    a) ADD new detail on existing sheet.REFER TO ADD2-0113

    37 of 75

  • Wellesley Community Centre Phase 2 – Pool Addition Addendum 02MacLennan Jaunkalns Miller Architects Page 2Project No. 1311 February 15, 2017

    Architectural Drawings ADD2

    3b. ARCHITECTURAL DRAWING REVISIONS + CLARIFICATIONS

    Drawing A002– SITE PLAN.1 4/A002

    a) REVISE note to indicate existing sidewalk to be removed and replacedREFER TO ADD2-014

    Drawing A102– GROUND FLOOR PLAN.1 1/A102

    a) DELETE elevation tag reference to 1/zA325NO SKETCH ISSUE

    Drawing A103– SECOND FLOOR PLAN.1 1/A103

    a) DELETE elevation tag reference to 1/zA325NO SKETCH ISSUE

    Drawing A104– ROOF PLAN.1 1/A104

    a) DELETE elevation tag reference to 1/zA325b) DELETE elevation tag reference to 1/CofA-A010c) DELETE elevation tag reference to C1Fa_8.5x11_A010d) REVISE south scupper width to 400e) REVISE north scupper location and width to 400f) ADD reference tag 6/A323 north of GL-12y across GL-HNO SKETCH ISSUE FOR ITEMS a) b) and c) above

    REFER TO ADD2-009 FOR ITEMS d) e) and f) above

    Drawing A111– RCP BASEMENT & GROUND FLOOR, DEMO RCP GROUND FLOOR.1 5/A111

    a) ADD furring type F1 at north and south wall of Entry Rm 060.b) REVISE slot for OH coiling door as indicated and dimensionedc) ADD reference to 3/A113 as indicatedd) ADD dimension to locate speaker

    38 of 75

  • Wellesley Community Centre Phase 2 – Pool Addition Addendum 02MacLennan Jaunkalns Miller Architects Page 3Project No. 1311 February 15, 2017

    Architectural Drawings ADD2

    e) REVISE dimension b/w diffuser and light fixture as notedf) REVISE dimension for wood ceiling to “EQ” at both ends in Entry Rm 060g) ADD note regarding wall finish to extent above ceilingh) REVISE further as indicatedREFER TO ADD2-001

    Drawing A401– CHANGE ROOMS - LOCKERS AND CHANGE STALLS.1 1/A401

    a) ADD furring type F1 at north and south wall of Entry Rm 060.b) REVISE partition type from P3 to PG2T near door # 061Bc) ADD plan detail 8/A406d) REVISE dimensions as notede) REVISE further as indicatedREFER TO ADD2-002

    Drawing A402– CHANGE ROOMS – UNIVERSAL WC AND ACCESSIBLE WC.1 10/A402

    a) DELETE reference tag 10/A412 for clarityNO SKETCH ISSUE

    Drawing A406 – ADMIN AREAREFER TO RE-ISSSUED SHEET A406.1 1/A406 and 2/A406

    a) ADD note and dimension for furring partition to extent above ceilingb) ADD dash line to indicate door frame beyond for clarityc) REVISE “TL-10 BEHIND GLASS DOOR” to “BACK PAINTED GLASS BEHIND GLASS

    DOOR”

    d) ADD vertical dimension of clear opening for clarity.2 3/A406

    a) ADD furring type F1 at north and south wall of Entry Rm 060.b) ADD note “TILE FINISH ON” above furring tag “F1” at north and south wall of Entry Rm

    060.

    c) ADD “ON RETURN” below finish tag “TL-15”d) REVISE “SSF-1” extent above opening as noted

    .3 4/406

    39 of 75

  • Wellesley Community Centre Phase 2 – Pool Addition Addendum 02MacLennan Jaunkalns Miller Architects Page 4Project No. 1311 February 15, 2017

    Architectural Drawings ADD2

    a) ADD furring type F1 at north and south wall of Entry Rm 060 w/ note “TILE FINISH ON” above furring tag

    b) ADD note for furring partition to extent above ceilingc) ADD note “SIMILAR SSF LAYOUT ON EITHER SIDE AND ABOVE ON WEST SIDE

    OF DOOR”

    .4 5/A406

    a) DELETE notes (2) “WALL EXPANSION JOINT COVER”b) REVISE floor expansion joint as indicatedc) REVISE note “25mm EXPANSION JOINT” to ”EXPANSION JOINT IN TILE” d) DELETE note “REMOVEABLE TACKBOARD”e) ADD arrow from “TYPICAL REMOVABLE SOLID SURFACE” pointing to the middle

    panel

    f) REVISE notes (2) “TILE FINISH” to “BACK PAINTED GLASS ON 13mm EXTERIOR GRADE PLYWOOD”

    g) REVISE further as noted.5 6/A406

    a) DELETE expansion joint coverb) REVISE note “TILE TO TILE FLOOR EXPANSION JOINT” to “EXPANSION JOINT IN

    TILE”

    .6 8/A406

    a) ADD new detail 8/A406.7 9/A406

    a) ADD new detail 9/A406

    Drawing A410– POOL HALL PARTIAL PLANS & SECTIONS.1 1/A410

    a) ADD door number 072Bb) REVISE glass door to a single doorREFER TO ADD2-007

    Drawing A450 – INTERIOR DETAILS.1 5/A450

    c) REVISE partition type from “P3” to “PG2T”d) ADD fire proofing around columne) ADD align note b/w tile and face of door framef) ADD “SSF-1” finish east of “PG2T” partition and jamb returng) ADD blocking for door frames

    40 of 75

  • Wellesley Community Centre Phase 2 – Pool Addition Addendum 02MacLennan Jaunkalns Miller Architects Page 5Project No. 1311 February 15, 2017

    Architectural Drawings ADD2

    h) ADD furring partition type “F1” beside door framei) REVISE further as notedREFER TO ADD2-003

    .2 9/A450

    a) DELETE note “RATED VERTICAL EXPANSION JOINT?”b) DELETE note “CONTINUE RATED TILE BACKER BOARD FOR COLUMN

    PROTECTION”

    c) ADD fire proofing around column and note “FIRE RATED COL”d) REVISE note “ALU COVER JOINT W/ RUBBER INSERT. COLOUR TO MATCH WALL”

    to “TILE JOINT AT TRANSITION B/W NEW AND EXISTING CONCRETE STRUCTURE. EXPANSION JOINT IN TILE”

    e) REVISE note “EXPANSION JOINT COLOUR TO MATCH FLOOR FINISH” to “EXPANSION JOINT IN FLOOR TILE”

    f) REVISE detail over expansion joint as indicatedREFER TO ADD2-004

    .3 15/A450

    a) REVISE note “EXPANSION JOINT” to “EXPANSION JOINT IN TILE IN FLOOR AND WALL”

    b) REVISE EXPANSION JOINT AS INDICATEc) REVISE further as indicatedREFER TO ADD2-005

    .4 16/A450

    a) REVISE note “EXPANSION JOINT” to “EXPANSION JOINT IN TILE IN FLOOR AND WALL”

    b) REVISE EXPANSION JOINT AS INDICATE

    c) REVISE further as indicatedREFER TO ADD2-006

    Drawing A451 – INTERIOR DETAILS.1 1/A451

    a) ADD alignment lines between east and west side of guard.b) ADD note “GAPS TO ALIGN ON BOTH SIDES”c) REVISE dimensions from “4 EQ. PANELS W/ 50mm GAP” to “4 EQ. PANELS W/ GAPS

    AS INDICATED”

    d) ADD note “EXPANSION JOINT IN TILE” at south end of bridgee) REVISE dimension for bridge as indicatedf) ADD notes (2) “ALIGN INTERIOR FACE OF STEEL GUARD WITH WALL FINISH”

    41 of 75

  • Wellesley Community Centre Phase 2 – Pool Addition Addendum 02MacLennan Jaunkalns Miller Architects Page 6Project No. 1311 February 15, 2017

    Architectural Drawings ADD2

    g) DELETE notes (2) “WORKING PLANE INSIDE FACE OF STEEL GUARD”h) ADD note “EXPANSION JOINT W/ COVER” at north end of bridgei) REVISE further as indicated.REFER TO ADD2-018

    .2 2/A451

    a) REVISE drawing as indicatedREFER TO ADD2-019

    .3 3/A451

    a) ADD dimensions as noted.REFER TO ADD2-020

    .4 4/A451

    a) REVISE note “EXPANSION JOINT” to “EXPANSION JOINT IN TILE” at ceilingb) ADD note “EXPANSION JOINT W/ COVER”

    REFER TO ADD2-021

    Drawing A600 – STAIRREFER TO RE-ISSSUED SHEET A600.1 1/A600

    a) REVISE dimensions.b) ADD new section detail reference.

    .2 2/A600

    a) REVISE stair guard.b) REVISE stair riser height.c) REVISE riser breakdown and landing height.d) ADD guard height dimensions.

    .3 3/A600

    a) REVISE landing and stair set out dimensions.b) ADD new section detail and reference.c) ADD dimensions.

    .4 4/A600

    a) ADD new section detail and reference.b) ADD door reference ST-A1B.c) ADD dimensions.d) REVISE integral dome reference.

    .5 5/A600

    42 of 75

  • Wellesley Community Centre Phase 2 – Pool Addition Addendum 02MacLennan Jaunkalns Miller Architects Page 7Project No. 1311 February 15, 2017

    Architectural Drawings ADD2

    a) ADD new section detail and reference.b) ADD dimensions.c) REVISE landing height.d) REVISE dimensions.

    .6 5b/A600

    a) ADD new section 5b/A600..7 6/A600

    a) ADD dimensions.b) REVISE expansion joint note.c) REVISE dimensions.

    .8 6/A600

    a) ADD dimensions.b) REVISE dimensions.c) DELETE nosing at steel pan stair.d) ADD new detail and reference 9/A902.e) ADD new detail and reference 19/A600.f) CLARIFICATION: Spray applied AB cross referenced to spec as INS-28 with thermal

    barrier (as noted in ADD1 issued February 10 2017)

    .8 10/A600a) ADD note regarding picket spacing.b) ADD note regarding guard construction.c) ADD dimension.d) REVISE steel support location.e) CLARIFICATION dashed line of stringer beyond.

    .9 11/A600

    f) ADD note: contractor to coordinate door header location w/ stair landing..10 13/A600

    a) ADD handrail supports.b) ADD dimensions.c) ADD new detail and reference 7/A902.d) CLARIFICATION note describing handrail as SST-POWDER added.

    .11 15/A600

    a) ADD south handrail.b) ADD dimensions.c) REVISE dimensions

    43 of 75

  • Wellesley Community Centre Phase 2 – Pool Addition Addendum 02MacLennan Jaunkalns Miller Architects Page 8Project No. 1311 February 15, 2017

    Architectural Drawings ADD2

    d) REVISE detail reference for detectable warning surface.e) DELETE reference to expansion joint.

    .12 16/A600

    a) ADD new detail and reference 19/A600.b) ADD dimensions.c) REVISE handrail.d) REVISE dimensions.e) CLARIFICATION finish outline shifted to align with stair.

    .13 17/A600

    a) ADD reinforcement to concrete masonry units as required to support ladder..14 16/A600

    a) ADD new detail and reference 19/A600..15 19/A600

    a) ADD new detail 19/A600..16 20/A600

    a) ADD new detail 20/A600.

    Drawing A701– EXTERIOR AND INTERIOR SCREEN .1 31/A701

    a) REVISE as indicatedREFER TO ADD2-007

    .2 GLASS AND FRAME TYPES

    a) ADD notes 7,8 and 9 as indicated to “GENERAL NOTES:”b) ADD note 4 as indicated to “CURTAIN WALL NOTES:”REFER TO ADD2-008

    Drawing A801 – DOOR SCHEDULE & DETAILSREFER TO RE-ISSSUED SHEET A406.1 DOOR SCHEDULE

    a) REVISE as indicated.2 1/A801

    a) REVISE note “PREFINISHED ALUM CLOSER BY GLAZING CONTRACTOR SHIM AS REQ’D” to “PREFINISHED ALUM CLOSER ON BOTH SIDES BY GLAZING CONTRACTOR BLOCKING AS REQ'D”

    b) ADD notes (2) “ALIGN” on both side of door frame.c) REVISE further as noted

    44 of 75

  • Wellesley Community Centre Phase 2 – Pool Addition Addendum 02MacLennan Jaunkalns Miller Architects Page 9Project No. 1311 February 15, 2017

    Architectural Drawings ADD2

    Drawing A902 – FINISH SCHEDULE, RB SCHEDULE & TYP. FLOOR FINISH DETAILS.1 7/A902

    a) ADD new section detail 7/A902.REFER TO ADD2-015

    .2 8/A902

    a) ADD new section detail 8/A902.REFER TO ADD2-016

    .3 9/A902

    a) ADD new section detail 9/A902.REFER TO ADD2-017

    END OF ARCHITECTURAL DRAWING REVISIONS + CLARIFICATIONS.

    45 of 75

  • N

    Q

    13x

    P7

    A406

    3

    A350 13y

    OS

    sp

    av

    152

    305 2440 305

    152

    550

    1105

    750

    216

    EQ. EQ.

    SLOT FOR OH

    COILING DOOR

    SPRINKLER IN BLANK OFF

    PANEL. SEE CHANGER OOM

    CLG FOR DETAIL

    2440

    os

    64 25

    114

    25

    EQ

    EQ

    3 ADD2

    3 A113

    Sim

    3 A113

    Sim

    3 A113

    Sim

    WALL FINISH TO EXTENT

    ABOVE CEILING HEIGHT.

    TYP

    3 ADD2

    F1

    F1

    /REF 5 A111

    3 ADD2

    Scale:

    Drawn By:

    Project No: Drawing No:

    2/15/2017 8:34:14 AM

    1 : 50

    WELLESLEY COMMUNITY CENTER

    1311

    AuthorADD2-001

    ADDENDUM 2

    1 : 50

    ENTRY / RECEPTION CEILING - ADD2

    REV. DESCRIPTION DATE

    3 ADDENDUM 2 02 15 2017

    46 of 75

  • 13

    H

    N

    Q

    A406

    4

    21

    3

    ENTRY

    060

    F1C

    FD1

    P060B

    5

    A406

    410

    3609

    7

    A406

    3

    A350

    P3P3

    1

    A501

    13y

    5

    A450

    PG2T

    FEC

    F1C

    PG2T

    3211

    061B

    12

    A501PG2TPG2T

    8

    A406

    1200

    683

    F1

    FL-2A

    F1

    3 ADD2

    /REF 1 A401

    Scale:

    Drawn By:

    Project No: Drawing No:

    2/15/2017 8:34:39 AM

    1 : 50

    WELLESLEY COMMUNITY CENTER

    1311

    AuthorADD2-002

    ADDENDUM 2

    1 : 50

    PARTIAL OF CHANGE ROOM - ADD2

    REV. DESCRIPTION DATE

    3 ADDENDUM 2 02 15 2017

    47 of 75

  • Q

    P

    13y

    FIRE PROOFED

    COL

    GLAZED SLIDING ALUM

    DOOR

    REFER TO SCHEDULE

    REFER TO A406 FOR

    ADDITIONAL DETAIL

    PG2T

    TILE FINISH

    TILE FINISH

    PROVIDE BLOCKING

    AT DOOR FRAME

    HM DOOR FRAME

    295

    SSF-1

    TILE FINISH

    F1

    SSF-1

    ALIGN

    PG2T

    CAULKING B/W FINISH

    AND DOOR FRAME

    /REF 5 A450

    Scale:

    Drawn By:

    Project No: Drawing No:

    2/15/2017 8:34:57 AM

    1 : 10

    WELLESLEY COMMUNITY CENTER

    1311

    AuthorADD2-003

    ADDENDUM 2

    1 : 10

    PLAN DETAIL - RATED COLUMN @ 13y & Q - ADD2

    REV. DESCRIPTION DATE

    2 ADDENDUM 1 02 10 2017

    48 of 75

  • H

    N

    10y9y

    800

    150

    TILE FINISH

    LARGE FORMAT PORCELAIN TILE

    F1C

    F1C

    F1C

    CORNER METAL TRIM

    LARGE FORMAT PORCELAIN TILECORNER METAL

    TRIM

    VERIFY DIMENSIONS &

    LOCATIONS OF EXISTING

    STRUCTURE ON SITEEXIST.LOBBY002

    EXPANSION JOINT

    IN FLOOR TILETILE JOINT AT TRANSITION B/W NEW AND EXISTING

    CONCRETE STRUCTURE. EXPANSION JOINT IN TILE

    550

    74

    287

    PROVIDE BLOCKING AS

    REQ'D FOR GRAB BAR

    FIRE RATED COL

    3 ADD2

    /REF 9 A450

    3 ADD2

    Scale:

    Drawn By:

    Project No: Drawing No:

    NORTH ARROW

    2/15/2017 8:35:21 AM

    1 : 10

    1311

    AuthorADD2-004

    WELLESLEY COMMUNITY CENTER

    ADDENDUM 2

    1 : 10

    GROUND FLOOR PLAN DETAIL @ GL-H/10y - ADD2

    REV. DESCRIPTION DATE

    3 ADDENDUM 2 02 15 2017

    49 of 75

  • 15

    H

    N

    15y15x

    470 817 745

    Sc-064a

    EXIST. ATHLETIC CORRIDOR

    031

    UNIVERSAL CHANGE ROOM B

    064

    1000 518 9

    12mm LAMINATED GLASS W/

    COLOURED INTERLAYER ON

    19mm PLY ON

    STUDS

    LARGE FORMAT TILE FINISH

    EXPANSION JOINT IN TILE IN

    FLOOR AND WALL

    TILE TO MATCH FLOOR TILE IN

    CHANGE ROOM

    TL

    TL

    TILE TRANSITION

    REFER TO FINISH PLAN FOR TILE

    TYPE

    29

    A701

    30

    A70128

    A701

    3 ADD2

    /REF 15 A450

    Scale:

    Drawn By:

    Project No: Drawing No:

    NORTH ARROW

    2/15/2017 8:35:40 AM

    1 : 10

    1311

    AuthorADD2-005

    WELLESLEY COMMUNITY CENTER

    ADDENDUM 2

    1 : 10

    PLAN DETAIL SC-064A - ADD2

    REV. DESCRIPTION DATE

    3 ADDENDUM 2 02 15 2017

    50 of 75

  • 11

    H

    N

    11x 11y2 A351

    12mm LAMINATED GLASS W/

    COLOURED INTERLAYER ON

    19mm PLY ON

    STUDS

    LARGE FORMAT TILE FINISH

    Sc-077a

    EXIST. ATHLETIC CORRIDOR

    031

    28

    A701

    30

    A701

    EXPANSION JOINT IN TILE IN

    FLOOR AND WALL

    TILE TO MATCH FLOOR TILE IN

    CHANGE ROOM

    TL

    TL

    TILE TRANSITION

    REFER TO FINISH PLAN FOR TILE

    TYPE

    12mm LAMINATED GLASS W/

    COLOURED INTERLAYER ON

    19mm PLY ON

    STUDS

    3 ADD2

    Scale:

    Drawn By:

    Project No: Drawing No:

    NORTH ARROW

    2/15/2017 8:36:04 AM

    1 : 10

    1311

    AuthorADD2-006

    WELLESLEY COMMUNITY CENTER

    ADDENDUM 2REV. DESCRIPTION DATE

    3 ADDENDUM 2 02 15 2017

    1 : 10

    PLAN DETAIL SC-077a - ADD2

    51 of 75

  • X

    16z

    STAIR

    B

    TDA701

    31

    GLASS DOOR

    F1C

    FEC

    TH

    15 A402

    Sim

    3 ADD2

    /REF 1 A410

    072B

    LEVEL 1 (+110.95)

    +0

    Pool Platform

    +2660

    13

    A600

    SS HINGES W/ HOLD

    OPEN AT 90 DEG

    SS KEYED LOCK TO

    RELEASE LATCH.

    1000

    GL-7

    200

    SS WALL MOUNTED

    LATCH CATCHER

    TILE FINISH ON CMU

    REFER TO HARDWARE SCHEDULE.

    GC TO COORD WITH GLASS AND

    HARDWARE SUPPLIER

    FINAL WIDTH OF

    GLASS TBC ON SITE

    1800

    3 ADD2

    /REF 31 A701

    Scale:

    Drawn By:

    Project No: Drawing No:

    SEAL

    2/15/2017 8:36:48 AM

    1 : 50

    1311

    AuthorADD2-007

    WELLESLEY COMMUNITY CENTER

    ADDENDUM 2

    1 : 50

    LEVEL 1 - POOL HALL - ADD2

    1 : 50

    POOL STAIR DOOR ELEVATION - ADD2

    REV. DESCRIPTION DATE

    3 ADDENDUM 2 02 15 2017

    52 of 75

  • GLASS TYPES:

    GL3 POOL LOWER: INSULATED GLASS UNIT - CLEAR - FRIT

    OUTER LITE: 8MM CLEAR TEMPERED GLASS

    CERAMIC FRIT PATTERN - 5MM DIA. DOTS @ 100MM O.C ON SURFACE 2

    LOW E COATING ON SURFACE 3

    13MM THERMAL SPACER BAR

    INNER LITE: 10MM (2x5MM) CLEAR TEMPERED LAMINATED GLASS W/

    CLEAR INTERLAYER

    GL1 POOL UPPER AND MULTI PURPOSE BLOCK: INSULATED GLASS UNIT - CLEAR - FRIT

    OUTER LITE: 6MM CLEAR HEAT STRENGTHENED GLASS

    CERAMIC FRIT PATTERN - 5MM DIA. DOTS @ 100MM O.C ON SURFACE 2

    LOW E COATING ON SURFACE 3

    13MM THERMAL SPACER BAR

    INNER LITE: 6MM CLEAR HEAT STRENGTHENED GLASS

    GL2 POOL UPPER (CLERESTORY): INSULATED GLASS UNIT - CLEAR - FRIT

    OUTER LITE: 6MM CLEAR TEMPERED GLASS

    CERAMIC FRIT PATTERN - 5MM DIA. DOTS @ 100MM O.C ON SURFACE 2

    LOW E COATING ON SURFACE 3

    13MM THERMAL SPACER BAR

    INNER LITE: 12MM (2x6MM) CLEAR HEAT STRENGTHENED LAMINATED GLASS W/

    CLEAR INTERLAYER

    GL6 RESERVED

    GL7 INTERIOR SCREENS (POOL): 12MM (2x6MM) CLEAR TEMPERED LAMINATED GLASS W/

    CLEAR INTERLAYER TYPICAL

    GL8 GLASS BALUSTRADE: 16MM (8MM+8MM) CLEAR HEAT STRENGTHENED LAMINATED GLASS W/

    CLEAR INTERLAYER

    FRAME TYPES:

    EXTERIOR GLAZING

    CW1 CURTAIN WALL, HIGH SPAN

    63.5mm X 203mm PTD ALUM BACK SECTIONS

    4 SIDED SSG (INCLUDES NO PERIMETER CAPS)

    GLASS: VARIES (REF. A200 SERIES BUILDING ELEVATIONS)

    CW2 CURTAIN WALL, LOW SPAN

    63.5mm X 133mm PTD ALUM BACK SECTIONS

    4 SIDED SSG (INCLUDES NO PERIMETER CAPS)

    GLASS: VARIES (REF. A200 SERIES BUILDING ELEVATIONS)

    SL-1 42mm ALUM. CHANNEL FRAMING (TOP & BOTTOM)

    GL4 POOL LOWER: INSULATED GLASS UNIT - CLEAR - FRIT

    OUTER LITE: 6MM CLEAR TEMPERED GLASS

    CERAMIC FRIT PATTERN - 5MM DIA. DOTS @ 100MM O.C ON SURFACE 2

    LOW E COATING ON SURFACE 3

    13MM THERMAL SPACER BAR

    INNER LITE: 6MM CLEAR TEMPERED GLASS

    GL7a INTERIOR SCREENS (POOL): 12MM (2x6MM) CLEAR TEMPERED LAMINATED GLASS W/

    TRANSLUCENT INTERLAYER TO DESK HEIGHT

    GL5 INTERIOR SCREENS (STEAM ROOM): INSULATED GLASS UNIT - CLEAR - NO FRIT

    OUTER LITE: 6MM (3MM+3MM) CLEAR TEMPERED LAMINATED GLASS W/

    CLEAR INTERLAYER

    13MM THERMAL SPACER BAR

    INNER LITE: 6MM (3MM+3MM) CLEAR TEMPERED LAMINATED GLASS W/

    CLEAR INTERLAYER

    GL9 INTERIOR SCREENS: 12MM CLEAR TEMPERED GLASS

    AL-1 THERMALLY BROKEN ALUM CHANNEL FRAME FOR IGU. (TOP & BOTTOM)

    GENERAL NOTES:

    1. SCREEN SYSTEM TYPES ARE NOTED ON SCHEDULE. REFER TO PROJECT MANUAL.

    2. SCHEDULE INDICATES MINIMUM GLASS THICKNESSES, INCREASE GLASS THICKNESS TO MEET

    ALL APPLICABLE CODES AND SAFTY STRENGTH AND DEFLECTION REQUIREMENTS FOR LOAD AND SIZE

    BASED ON ASTM E 1300.

    3. ALL EXTERIOR IGU IS TO HAVE 5MM DIA CERAMIC FRIT PATTERN @ 100 X 100mm O.C.

    TO MEET TORONTO GREEN STANDARDS FOR MIGRATORY BIRDS TYP.

    4. PROVIDE CONTINUOUS STEEL SUPPORTS AND BRACING BACK TO PRIMARY STRUCTURE AS NECESSARY-

    CONCEALED ABOVE CEILING AND ACROSS HEAD OF ALL FULL HEIGHT GLASS PARTITION: TO BE DESIGNED

    UNDER DIRECT SUPERVISION OF REGISTERED PROFESSIONAL STRUCTURAL ENGINEERS,

    BRACES AT SCREENS REQUIRED TO ACT AS GUARDS SHOULD BE DESIGNED ACCORDINGLY

    TO MEET REQUIREMENTS.

    5. SITE VERIFY ALL GLAZED OPENING DIMENSIONS.

    6. INTERMEDIATE DIMENSIONS ARE GENERALLY TO THE CENTERLINE OF THE FRAME.

    7. REFER TO DOOR SCHEDULE FOR DOOR TYPES.

    8. REFER TO JAMB SCHEDULE FOR JAMB TYPES.

    9. FOR MIRRORS AND BACKPAINTED GLASS: COORDINATE OPENINGS REQUIRED FOR WALL MOUNTED FIXTURES,

    ACCESSORIES AND RECEPTACLES AS REQUIRED.

    CW3 RESERVED

    CLEAR GLASS, ALL TYPES SHADOW BOXsb CLOSURE PANELcp

    SF-1

    SF-2

    45 x115mm INTERIOR ALUM. STOREFRONT FRAME FOR SINGLE GLASS,

    PAINTED ALUM. BACK SECTIONS.

    50 x115mm INTERIOR ALUM. THERMALLY BROKEN STOREFRONT FRAME FOR IGU,

    PAINTED ALUM.BACK SECTION.

    GL8a INTERIOR SCREENS: 12MM (2x6MM) CLEAR TEMPERED LAMINATED GLASS W/

    COLORED INTERLAYER

    Determine if existing mulllion profile could be used

    CURTAIN WALL NOTES:

    1. ALL ALUMINUM SCREENS IN OR OPENING INTO AQUATIC HALL AND CHANGE ROOMS

    TO HAVE FASTENERS AND STEEL COMPONENTS ALL TO BE STAINLESS STEEL.

    2. DIMENSIONS INDICATED ARE NOMINAL. ALL DIMENSIONS TO BE SITE VERIFIED.

    3. SEE PROJECT MANUALL FOR GLAZED ALUMINUM DOORS.

    4. ALL FRAMES TO RECEIVE DURANAR XL PAINTED FINISH UNLESS OTHERWISE NOTED.

    SF-3 50x115 ALUM. PHANTOM DOOR FRAME FOR LAMINATED GLASS,

    PAINTED ALUM.BACK SECTION.

    GL8b GLASS BALUSTRADE: 16MM (8MM+8MM) CLEAR HEAT STRENGTHENED LAMINATED GLASS W/

    COLORED INTERLAYER

    3

    3

    Scale:

    Drawn By:

    Project No: Drawing No:

    NORTH ARROW

    1 : 20

    2/15/2017 2:39:33 PM

    1311

    AuthorADD2-008

    WELLESLEY COMMUNITY CENTER

    ADDENDUM 2

    1 : 20

    GLASS AND FRAME TYPES ADD2

    REV. DESCRIPTION DATE

    53 of 75

  • E/A3000CFM

    +100

    RD

    11

    H

    N

    Q

    11y

    SLO

    PE

    D S

    TRU

    CTU

    RE

    CFD

    A201 4

    4.1

    %

    R

    P

    2%

    120.75 m

    5

    120.13 m

    SCUPPER5

    A323

    3460

    400

    CROSS HATCHED AREA DENOTES

    LOCATION WHERE FASTENING RATE

    NEED TO BE INCREASED AT CORNERS.

    SEE SPEC FOR DIMENSIONS AND FM

    GLOBAL DATA SHEET 1-29.

    TYP FOR R1 ROOF

    3 ADD2

    18

    N

    Q

    17z17x

    R

    P

    17y

    2.3

    %

    120.75 m

    120.75 m

    1500

    SCUPPER

    100

    400

    3 ADD2

    12 13

    G

    H

    N

    Q

    12y1

    A301

    1

    A301

    A210

    3

    CFD

    P

    13y

    5

    A310

    6

    A323

    3 ADD2

    Scale:

    Drawn By:

    Project No: Drawing No:

    NORTH ARROW

    2/15/2017 2:40:02 PM

    1 : 100

    1311

    AuthorADD2-009

    WELLESLEY COMMUNITY CENTER

    ADDENDUM 2

    1 : 100

    Partial Roof Plan - ADD2a

    1 : 100

    Partial Roof Plan - ADD2b

    1 : 100

    Partial Roof Plan - ADD2c

    REV. DESCRIPTION DATE

    3 ADDENDUM 2 02 15 2017

    54 of 75

  • 55 of 75

  • 56 of 75

  • 57 of 75

  • 58 of 75

  • 20 500

    22 400

    200

    161

    300 STORM20 500

    22 400

    200

    161

    300 STORM20 500

    22 400

    200

    161

    300 STORM

    111.4

    3

    111.2

    0

    111.0

    1

    MH

    110.6

    5

    110.7

    8110.8

    0

    110.7

    7

    110.4

    7

    110.6

    2

    110.7

    6

    C

    110.7

    5

    110.5

    0

    110.7

    8

    111.1

    2

    111.3

    7

    111.1

    8

    110.9

    8

    110.8

    2

    110.6

    2

    111.1

    9

    111.2

    5

    111.1

    8

    111.2

    0

    111.3

    4

    111.3

    3111.3

    8

    111.3

    7

    110.4

    5

    110.5

    0

    110.7

    3

    111.0

    3

    111.2

    7

    111.4

    8

    111.3

    6

    111.5

    3

    111.7

    2

    111.3

    2 111.3

    0

    111.5

    7

    111.7

    9111.5

    3

    111.7

    9

    110.7

    0

    110.8

    8

    CB

    MH

    111.1

    1

    111.3

    4

    111.3

    9

    111.4

    3

    110.6

    2

    110.8

    8

    111.1

    1

    111.3

    8

    111.6

    3

    0.15 ∅ 0.20 ∅

    0.10 ∅

    0.40 ∅

    0.20 ∅

    0.30 ∅

    0.90 ∅

    0.10 ∅

    0.15 ∅

    EXIST. RETAINING

    WALL TO BE REMOVED

    EXISTING

    WHEEL TRANS

    STOP

    EXISTING SOD

    EXIST. CONC

    TO BE REMOVED & REPLACED

    PROPERTY LINE

    DASHED LINE OF EXIST. BIKE RENTAL

    STATIONS TO BE RELOCATED

    EXIST ARMOUR STONE &

    LOG BENCHES TO BE REMOVED &

    RELOCATED

    EXIST. ENTRANCE SIGNAGE

    TO BE RELOCATED

    3268

    DASHED LINE OF TREE

    PROTECTION

    REFER TO ARBORIST REPORT

    PROPOSED LOCATION

    OF EXIST. ENTRANCE

    SIGNAGE

    PROPOSED LOCATION OF

    6 EXISTING BIKE RACKS

    (12 SPACES)

    DASHED LINE OF

    EXISTING STAIRS TO

    BE CUT BACK &

    REMOVED

    PROPOSED LOCATION OF

    EXISTING BIKE RENTAL STATION

    500017756

    DASHED LINE OF TREE

    PROTECTION

    REFER TO ARBORIST REPORT

    5000

    TY

    P

    1650

    TO BE REMOVED & REPLACED

    EXISTING SIDEWALK

    3 ADD2

    /REF 4 A002

    Scale:

    Drawn By:

    Project No: Drawing No:

    NORTH ARROW

    2/15/2017 2:46:38 PM

    1 : 200

    1311

    AuthorADD2-014

    WELLESLEY COMMUNITY CENTER

    ADDENDUM 2

    1 : 200

    Site Plan (PART) - ADD2

    REV. DESCRIPTION DATE

    3 ADDENDUM 2 02 15 2017

    59 of 75

  • Pool Platform

    +2660

    C.I.P

    .

    ST

    RU

    CT

    UR

    AL C

    ON

    C. S

    LA

    B

    STL HAND RAIL BEYOND

    CAST IN PLACE

    CONCRETE STAIR

    DETECTABLE WARNING SURFACE

    TILE W/ INTEGRAL DOMES

    CONTRASTING TILE

    NOSING

    REFER TO PLAN

    TREAD

    CONTRASTING TILE COLOUR

    SCHLUTER TRIM AS PER

    SPECIFICATIONS

    STRETCHER TILE

    3ADD2/REF 7 A902

    Scale:

    Drawn By:

    Project No: Drawing No:

    2/15/2017 2:47:18 PM

    1 : 5

    WELLESLEY COMMUNITY CENTER

    1311

    AuthorADD2-015

    ADDENDUM 2

    1 : 5

    SECTION DETAIL - TILE NOSING AT POOL HALL STAIR - ADD2

    REV. DESCRIPTION DATE

    3 ADDENDUM 2 02 15 2017

    60 of 75

  • Level 1 Gym

    +600

    SAFETY TREAD

    INSERT @ EACH

    TREAD (TYP.)

    STRETCHER TILE

    SCHLUTER TRIM

    AS PER

    SPECIFICATIONS

    REFER TO PLAN

    TREAD

    DETECTABLE

    WARNING

    SURFACE TILE

    3 ADD2

    /REF 8 A902

    Scale:

    Drawn By:

    Project No: Drawing No:

    2/15/2017 2:47:47 PM

    1 : 5

    WELLESLEY COMMUNITY CENTER

    1311

    AuthorADD2-016

    ADDENDUM 2

    1 : 5

    SECTION DETAIL - TILE NOSING AT CHANGE ROOM STAIR - ADD2

    REV. DESCRIPTION DATE

    3 ADDENDUM 2 02 15 2017

    61 of 75

  • LEVEL 2

    +5000

    REFER TO PLAN

    TREAD

    RE

    FE

    R T

    O S

    EC

    TIO

    N

    RIS

    ER

    TREAD

    SCHLUTER TRIM AS PER SPECIFICIATIONS

    DETECTABLE WARNING SURFACE

    TILE FINISH AS PER TILE SCHEDULE

    SAFETY STRIP ROUTERED INTO TILE BY

    MANUFACTURER

    EDGE OF TILE TO BE RADIUSED 6mm BY TILE

    MANUFACTURER

    TILE FINISH AS PER TILE SCHEDULE

    CONCRETE ON STEEL PAN STAIR

    INS-28 WITH THERMAL BARRIER

    REFER TO WALL SECTION DETAILS

    3ADD2

    /REF 9 A902

    Scale:

    Drawn By:

    Project No: Drawing No:

    2/15/2017 2:48:05 PM

    1 : 5

    WELLESLEY COMMUNITY CENTER

    1311

    AuthorADD2-017

    ADDENDUM 2

    1 : 5

    SECTION DETAIL - TILE NOSING AT STAIR 11 -ADD2

    REV. DESCRIPTION DATE

    3 ADDENDUM 2 02 15 2017

    62 of 75

  • N

    Q

    P

    2

    A451

    4

    A451

    800

    15

    1883

    15

    15

    185

    A451

    3

    4 EQ PANELS W/ GAPS AS INDICATED

    4960 TBC ON SITE

    122520

    122520

    122520

    1225

    25 25

    FACE OF WALL FINISH

    25 305 25

    GA

    PS

    TO

    ALIG

    N O

    N

    BO

    TH

    SID

    ES

    ALIGN INTERIOR

    FACE OF STEEL

    GUARD WITH WALL

    FINISH

    ALIGN INTERIOR

    FACE OF STEEL

    GUARD WITH WALL

    FINISH

    EXPANSION JOINT

    W/ COVER

    3ADD2

    3ADD2

    3ADD2

    3ADD2

    3ADD2

    3ADD2

    3ADD2

    3ADD2

    EXPANSION JOINT IN TILE

    3ADD2

    1

    ADD2-019

    /REF 1 A451

    ADD2-020

    1

    1

    ADD2-021

    Scale:

    Drawn By:

    Project No: Drawing No:

    NORTH ARROW

    2/15/2017 2:40:44 PM

    1 : 20

    1311

    AuthorADD2-018

    WELLESLEY COMMUNITY CENTER

    ADDENDUM 2REV. DESCRIPTION DATE

    3 ADDENDUM 2 02 15 2017

    1 : 20

    BRIDGE ENLARGED PLAN - ADD2

    63 of