Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
Compact Direct Operated 2 Port Solenoid Valve - Serie VDW10/20/30 1369
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
• Ultra compact 2 port valves for air, vacuum and fluids.• Choice of body and seals available.• IP65 enclosure.• Low weight.• Piping variations: thread and one-touch fitting.
Compact Direct Operated 2 Port Solenoid Valvefor Water, Air and Medium VacuumSeries VDW10/20
FeaturesFeatures
How to Order2VDW A A A1
1 Size 1
2 Size 2
SingleunitN.C.
SingleunitN.C.
KLMNPQRSTUVW
ABCDEFGHJK
ABCDEFGHJ
Brass
Stainlesssteel
Resin(PPS)
Note)
Resin(PPS)
Note)
Brass
Stainlesssteel
1.01.61.01.61.01.61.01.61.01.6
1.62.33.21.62.33.21.62.33.21.62.33.2
M5
ø3.2 One-touch fitting
ø4 One-touch fitting
M5
M5
M5
1/8
M5
1/8
1.62.33.21.62.33.21.62.33.2
M5
ø4 One-touch fitting
ø6 One-touch fitting
Size/Valve type Body material/Port size/Orifice diameterSymbol Size Valve
type Symbol Bodymaterial
OrificediameterStandard port size
Fluid24
For waterFor medium vacuum
Voltage/Electrical entrySymbol
ABCDE
Z1AZ1DZ1U
Electrical entry
Grommet
Voltage
24 VDC100 VAC110 VAC200 VAC230 VAC48 VAC12 VDC24 VAC
Other option
—ABCDEFGHJKLMNPZ
—
—
—
�
�
—
SymbolLow concentration
ozone resistant(Seal material: FKM)
—
—
�
—
�
�
Oil-free
Standard port sizeG
NPTM6G
NPTM6
Standard port sizeG
NPTM6
Standard port sizeG
NPTM6
Standard port size
Port size 1/8
Port size M5
Port size 1/8
Port size M5
Port size 1/8
Port size M5
Port size 1/8
Port size M5
Thread Note
—XB
NoYes
Bracket interchangeable with old type
Note) Medium vacuum is FKM and oil-free as standard,so it is only possible with other options: A, B or C.
Note) Medium vacuum is not available with Resin (PPS) body.
Common Specifications(For water)
Common Specifications(For medium vacuum)
N.C.FKM
Class BRc
1 to 50-10 to 50
Valve typeSeal materialCoil insulation typeStandard threadOil-freeFluid temperature [°C]Ambient temperature [°C]Note) With no freezing.
N.C.NBR
Class BRc
1 to 50-10 to 50
Valve typeSeal materialCoil insulation typeStandard threadFluid temperature [°C]Ambient temperature [°C]
Note) With no freezing.
The brackets are interchangeable with brackets of old VDW10/20 series. For details of exterior dimensions, please contact SMC.∗ Only for stainless steel (Select stainless steel when
interchangeable product is necessary for water.)
Accesories and Related Products
Series PF2A - Digital flow switch for air - page 1309Series PF3W - Digital flow switch for water - page 1317Series ZSE/ISE�0A - Digital pressure switch for air - page 1273Series ZSE/ISE80 - Digital pressure switch for fluids - page 1290Series KQ2 - Fittings - page 1184Series TU - Tubing - page 1223
Serie VDW10/20/30 – Compact Direct Operated 2 Port Solenoid Valve1370
Pro
cessV
alves
Size/Valve type
Symbol
1
Size Valvetype
Size 1
2
SingleunitN.C.
Size 2Single
unitN.C.
Body material/Port size/Orifice diameter
Symbol
KLMNPQ
ABCDEFGHJ
ABCDEF
Bodymaterial
Resin(PPS)
Resin(PPS)
Aluminium
Orificediameter
1.01.61.01.61.01.6
1.62.33.21.62.33.2
1.62.33.21.62.33.21.62.33.2
Standard port size
M5
ø3.2 One-touch fitting
ø4 One-touch fitting
M5
1/8
M5
ø4 One-touch fitting
ø6 One-touch fitting
Voltage/Electrical entrySymbol
ABCDE
Z1AZ1DZ1U
Electrical entry
Grommet
Voltage
24 VDC100 VAC110 VAC200 VAC230 VAC48 VAC12 VDC24 VAC
—XB
NoYes
Common SpecificationsN.C.NBR
Class BRc
-10 Note) to 50-10 to 50
Valve typeSeal materialCoil insulation typeStandard threadFluid temperature [°C]Ambient temperature [°C]
VDW 01 A A AFluid
0 For air
Other option
Bracket interchangeable with old type
—ABCDEFGHJKLMNPZ
—
—
—
�
�
—
SymbolLow concentration
ozone resistant(Seal material: FKM)
—
—
�
—
�
�
Oil-free
Port size 1/8
Port size M5
Port size 1/8
Port size M5
Port size 1/8
Port size M5
Port size 1/8
Port size M5
SpecialThread Note
Note) Dew point temperature -10°C or less.
The brackets are interchangeable with brackets of old VDW10/20 series. For details of exterior dimensions,please contact SMC.∗ Only for aluminium.
Standard port sizeG
NPTM6G
NPTM6
Standard port sizeG
NPTM6
Standard port sizeG
NPTM6
Standard port size
How to Order
Valvespecifications
Coilspecifications
Valve constructionWithstand pressureMax. system pressureBody materialSeal materialEnclosureEnvironment
MPaMPa
Rated voltage
Allowable voltage fluctuationAllowable leakage voltageCoil insulation type
ACDC
Note) Voltage in ( ) indicates special voltage.
AC (With a full wave rectifier)DC
Direct operated poppet2.0 (resin body type 1.5)
1.0Aluminium, Resin, Brass, Stainless steel
NBR, FKMDusttight, Low jetproof (IP65)
Location without corrosive or explosive gases100 VAC, 200 VAC, 110 VAC, 230 VAC, (220 VAC, 240 VAC, 48 VAC, 24 VAC) Note)
24 VDC, (12 VDC) Note)
±10% of rated voltage10% or less of rated voltage2% or less of rated voltage
Class B
Specifications
Accesories and Related Products
Series PF2A - Digital flow switch for air - page 1309Series PF3W - Digital flow switch for water - page 1317Series ZSE/ISE�0A - Digital pressure switch for air - page 1273Series ZSE/ISE80 - Digital pressure switch for fluids - page 1290Series KQ2 - Fittings - page 1184Series TU - Tubing - page 1223
Compact Direct Operated 2 Port Solenoid Valve - Serie VDW10/20/30 1371
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
Water Model / Valve Specifications
Port sizeSizeOrifice
diameter[mmø]
ModelMaximum operating
pressure differential [MPa]
0.90.40.70.40.2
1.01.61.62.33.2
M5
M5, 1/8
1
2
AV (x10-6m2)0.040.070.070.180.30
0.961.701.704.307.20
Conversion Cv Pressurized port 1
Flow-rate characteristics
VDW12
VDW22
Weight[g]
Resin Body Type
Port sizeSizeOrifice
diameter[mmø]
Model
0.9
0.4
0.70.40.2
1.0
1.6
1.62.33.2
M5ø3.2 One-touch fittingø4 One-touch fitting
M5ø4 One-touch fittingø6 One-touch fitting
1
2
Pressurized port 1
Flow-rate characteristics
VDW12
VDW22
Weight[g]
Normally Closed (N.C.)Brass, Stainless Steel Body Type
Brass: 65Stainless steel: 60
Brass: 115Stainless steel: 100
45
80
Conversion Cv0.04
0.07
0.070.180.30
AV0.96
1.70
1.704.307.20
Maximum operatingpressure differential [MPa]
Normally Closed (N.C.)
Port sizeSizeOrifice
diameter[mmø]
Model
Maximum operatingpressure differential [MPa]
Used withvacuum [Pa·abs] Pressurized port 1
0.1 toatmospheric
pressure
1.01.61.62.33.2
M5
M5, 1/8
C [dm3/(s·bar)] b
0.040.070.070.180.30
0.400.250.450.450.38
0.140.300.300.581.10
Cv
Flow-rate characteristics
VDW14
VDW24
Weight[g]
0.90.40.70.40.2
Brass: 65Stainless steel: 60
Brass: 115Stainless steel: 100
1
2
Medium Vacuum-Model / Valve Specifications
Port sizeSizeOrifice
diameter[mmø]
ModelMaximum operating
pressure differential [MPa]
0.70.40.2
801.62.33.2
M5, 1/82
C [dm3/(s·bar)] b0.070.180.30
0.450.450.38
0.300.581.10
Cv
Flow-rate characteristics
Normally Closed (N.C.)Aluminium Body Type
VDW20
Resin Body Type (Built-in One-touch Fittings)
Weight[g]
Port sizeSizeOrifice
diameter[mmø]
ModelMaximum operating
pressure differential [MPa]
0.9
0.4
0.70.40.2
1.0
1.6
1.62.33.2
M5ø3.2 One-touch fittingø4 One-touch fitting
M5ø4 One-touch fittingø6 One-touch fitting
1
2
C [dm3/(s·bar)] b Pressurized port 1
Pressurized port 1
0.04
0.07
0.070.180.30
0.40
0.25
0.450.450.38
0.14
0.30
0.300.581.10
Cv
Flow-rate characteristics
VDW10
VDW20
Weight[g]
45
80
Air Model / Valve Specifications
Serie VDW10/20/30 – Compact Direct Operated 2 Port Solenoid Valve1372
Pro
cessV
alves
Dimensions
D
CRE
A2 x PPort size
Full wave rectifier(AC type)
≈ 300 Q F
B
B1
M
2 x J thread depth KNote) Bracket interchangeable with old type (VDWXB) only
Grommet
Model Port sizeP
Mounting method
15 22 20 8 13.5 M3
A B D E FB1 C
11 52VDW2 M5, 1/8
[mm]
5 15
J K M GrommetElectrical entry
17 36.5Q R
Body material Aluminium
Compact Direct Operated 2 Port Solenoid Valve - Serie VDW10/20/30 1373
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
Dimensions
YW
XX1U
1
U
D
CRE
2 x PPort size
Q F
B1
B
Full wave rectifier(AC type)
2 x ø3.4Mountinghole
≈ 300
YW
XX1U
1
U
2 x ø3.4Mountinghole
CRE
D
2 x PPort size
Full wave rectifier(AC type)
Q F≈ 300
B
B1
With one-touch fittingsGrommet
For information on handling one-touch fittings and appropriate tubing, refer KJ series one-touch fittings.The KJ series information can be downloaded from the following SMC website, http://www.smc.eu
Model One-touch fittingP
Mounting bracket dimensions
2833
14 16.5
17 19.5
1720
U U1 X1 YW X
1114
3439
VDW1VDW2
ø3.2, ø4ø4, ø6
GrommetElectrical entry
15.517
30.535
Q R
Model One-touch fittingP
3236
1720
9.510.5
B B1 EC D
4653
1520
VDW1VDW2
ø3.2, ø4ø4, ø6
11 13.5
F
[mm]
Model Port sizeP
Mounting bracket dimensions
2833
14 16.5
17 19.5
1720
U U1 X1 YW X
1114
3439
VDW1VDW2
M5(M6)M5(M6)
GrommetElectrical entry
15.517
30.534
Q R
Model Port sizeP
2022
1011
9.59.5
B B1 EC D
4651
1520
VDW1VDW2
M5(M6)M5(M6)
11 13.5
F
[mm]
Port size M5/M6Grommet
ResinBody material
Serie VDW10/20/30 – Compact Direct Operated 2 Port Solenoid Valve1374
Pro
cessV
alves
Dimensions
D
CRE
2 x PPort size
≈ 300 Q F
B1
B
Full wave rectifier(AC type)
M
2 x J thread depth K
Model Port sizeP
Mounting method
2022
1011
68
11 13.5
M2.5M3
B B1 E FC D
42.552
1520
VDW1VDW2
M5M5, 1/8
45
1115
J K M GrommetElectrical entry
15.517
30 36.5
Q R
[mm]
Grommet
Brass
D
CRE
A2 x PPort size
≈ 300 Q F
BB1
Full wave rectifier(AC type)
M
2 x J thread depth K
Model Port sizeP
Mounting method
1215
2022
1520
68
11 13.5
M2.5M3
A B D E FB1 C
1011
42.552
VDW1VDW2
M5M5, 1/8
[mm]
45
1115
J K M GrommetElectrical entry
15.517
30 36.5
Q R
Grommet
Body material Stainless Steel
Body material
Compact Direct Operated 3 Port Solenoid Valve - Serie VDW10/20/30 1375
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
VDW250VDW350
VDW20-15A-1VDW20-12-01A
For Water, Air, Vacuum
23
200300
Series
123456VSR
VoltageSymbol
100 VAC (50/60 Hz)200 VAC (50/60 Hz)110 VAC (50/60 Hz)220 VAC (50/60 Hz) 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC
∗ Please consult with SMC regarding other voltages.
Grommet /Tape
winding
FastonTM
terminal,Molded
Grommet /Molded
Voltage
Electrical entryG – Grommet / Tape winding
Magnet wire protection: Tape winding
Magnet wire protection: Molded
Magnet wire protection: MoldedF – FastonTM terminal / Molded
W – Grommet / Molded
M50102
Port sizeSymbolSeries
M51/8 (6A)1/4 (8A)
200
—
Port size
300—
Material and insulation type
VD W 2 50 1 G 2 01
50
C.O.Valve type
N.C.(2)
N.O.(3)
(1)IN
ABGHJ
L Note)
Brass(C37)
Stainlesssteel
BodymaterialSymbol
- NBRFKM
EPDMNBRFKM
EPDMFKM
Sealmaterial
Class B
Coilinsulation
Note) For deionized water: The armature assembly is a corrosion resistant construction.
12234
N.C.Orifice diameter
[mm ø]Symbol
N.O.Orifice diameter
[mm ø]
11.6234
Series
200
300
1
1.8
Orifice size
Q
Compact Direct Operated 3 Port Solenoid ValveFor Water And AirSeries VDW200/300
FeaturesHow to Order Valves (3 Port Model)
How to Order Brackets
FeaturesFeatures
• Compact 3 port valves for water and air• Choice of body and seals available.• IP40 enclosure.
—F
NoneFoot bracket
Bracket
F GThread type
F
VDW200/300 – Compact Direct Operated 3 Port Solenoid Valve1376
Pro
cessV
alves
Accesories and Related Products
Series PF2A - Digital flow switch for air - page 1309Series PF3W - Digital flow switch for water - page 1317Series ZSE/ISE�0A - Digital pressure switch for air - page 1273Series ZSE/ISE80 - Digital pressure switch for fluids - page 1290Series KQ2 - Fittings - page 1184Series TU - Tubing - page 1223
Product Recommendation
Stocked items for fast delivery
VDW250-4G-1-01F-QVDW250-5G-1-01F-QVDW250-5G-1-M5-H-QVDW250-5G-1-M5-Q
VDW250-5G-2-M5-H-QVDW250-5G-2-M5-QVDW250-6G-2-01F-A-QVDW250-6G-2-01F-Q
VDW250-5G-2-01F-A-QVDW250-5G-2-01F-H-QVDW250-5G-2-01F-QVDW250-5G-2-M5-A-Q
VDW350-4G-3-02F-QVDW350-5G-2-01F-H-QVDW350-5G-2-01F-QVDW350-5G-3-01F-H-Q
VDW350-5G-3-01F-QVDW350-5G-3-02F-QVDW350-5G-4-02F-Q
Valve constructionFluid Note 2)
Withstand pressure [MPa]Ambient temperature [ºC]Fluid temperature [ºC]EnvironmentValve leakage [cm3/min]Mounting orientationVibration/Impact [m/s2] Note 4)
Rated voltageAllowable voltage fluctuation [%]Coil insulation type
Enclosure
Power consumption (W) Note 3)
Direct operated poppetWater (except waste water or agricultural water), Air, Low vacuum
2.0–10 to 50
1 to 50 (No freezing) Location without corrosive or explosive gases
0 (with water pressure) 1 (Air)Unrestricted
30/15024 VDC, 12 VDC, 100 VAC, 110 VAC, 200 VAC, 220 VAC (50/60 Hz)
±10% of rated voltageClass B
Dust-proof (equivalent to IP40)Dust-tight (equivalent to IP60) Note 5)
Dust-tight / Low jetproof (equivalent to IP65)3
Grommet / Tape windingFaston terminal / MoldedGrommet / Molded
Note 1) Please consult with SMC when used under conditions which may cause condensation on the exterior of the product.Note 2) When used with deionized water, select “L” (Stainless steel, FKM) for the material type.Note 3) Since the AC coil specification includes a rectifier element, there is no difference in power consumption between inrush and holding.
3.5 W in the case of 110/220 VACNote 4) Vibration resistance ····· No malfunction when tested with one sweep of 5 to 200 Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states. Impact resistance ········ No malfunction when tested with a drop tester in the axial direction and at a right angle to the armature, one time each in energized and deenergized states.Note 5) Since electrical connections are exposed, there is no water resistance.
Note 1) Indicates the maximum operating pressure differential of pressure ports 2 and 3.Note 2) The maximum operating pressure differential changes depending on the flow direction of the fluid. Note 3) For low vacuum specifications, the operating pressure range is 1 Torr (1.33 x 102 Pa) to 1.0 MPa.
Please consult with SMC if using below 1 Torr (1.33 x 102 Pa).
VDW200
VDW300
Model
11.6234
0.90.70.80.40.2
0.30.10.20.10.05
Orifice dia.[mm ø]
Weight[kg]
Port size
M51/8 (6A)
1/8 (6A)1/4 (8A)
Max. operating pressuredifferential [MPa] Note 2)
Pressure port 1
Operatingpressure range
[MPa] Note 3)
0.12
0 to 1.01/8: 0.271/4: 0.30
VDW200
VDW300
ModelN.C.
11.6234
N.O.
1
1.8
Av x 10–6 m2
1�2 (IN�N.C.) 1�3 (IN�N.O.) 1�2 (IN�N.C.) 1�3 (IN�N.O.)Cv
converted Cv
0.030.090.160.300.46
b
0.350.450.520.520.49
0.120.310.521.0 1.5
C [dm3/(s·bar)]
Water AirOrifice dia.[mm ø]Port size
M51/8 (6A)
1/8 (6A)1/4 (8A)
Av x 10–6 m2
0.96
3.1
0.13
0.38
Cvconverted
0.030.080.160.280.44
0.04
0.13
Cv
0.04
0.12
b
0.52
0.50
C [dm3/(s·bar)]
0.721.93.86.7
11
Valv
e sp
ecifi
catio
nsC
oil s
peci
ficat
ions
Pressure port 2, 3 Note 1)
Standard Specifications
Flow Characteristics
Characteristic Specifications
Compact Direct Operated 3 Port Solenoid Valve - Serie VDW10/20/30 1377
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
4 x ø5
1/8, 1/41 (IN) port
Lead wirel 300
RectifierelementAC type 1/8, 1/4
3 (N.O.) port
1/8, 1/42 (N.C.) port
2 x M4 x 6
1
SMC
612
.82534
ø28
3040
36 (27.6)1
SMC
Dimensions inside ( ) are for port size 1/8.
86 (8
2.5)
8.5
(6.3
)
3
27 20
2720
155
8
71
22
ø20.5
1
3
Lead wirel 300
2 x ø3.5
2 x M3 x 5
RectifierelementAC type
2 (N.C.) portM5,1/8
1 (IN) portM5,1/8
3 (N.O.) portM5,1/8
VDW250-� GW VDW350-� G
W
VDW250-�F VDW350-�F0.
8
936.517.5
8.5
(6.3
)
0.8
929.6
14.3
8
*-***-*-*VDW350-*F-
36 (27.6)
10.5
55.8
(for grounding)M3.5
12.8
2 x M4 x 6
146.
35
4030
34 25
3 (N.O.) port1/8, 1/4
4 x ø5SMC
86 (8
2.5)
28
6
1 (IN) port1/8, 1/4
2 (N.C.) port1/8, 1/4
*-***-*-*VDW250-*F-
22
46.2
6.7
(for grounding)M3.5
11.46.
35
27
2720
20
3 (N.O.) portM5, 1/8
(Bracket mounting hole)2 x ø3.5
71
20.5
5
2 (N.C.) portM5, 1/8
1 (IN) portM5, 1/8
15
2 x M3 x 5
FeaturesDimensions
Series VXD21/22 – Pilot Operated 2 Port Solenoid Valve1378
Pro
cessV
alves
OUT
Code Size
1
Applicable modelVXD2130-02F02
03040610
VXD214-03F, VXD2130-03FVXD214-04F, VXD2130-04F
VXD215-06FVXD226-10F
1 43 81 23 4
GGGGG
Grommet,conduit and "with conduit terminal" entries are available
Valve/Body configuration02
N.C. / Single unitN.O. / Single unit
5 102 D1 R102 D
VXDDC 3 021
VXD 3 021Model/Orifice size
From ø10 to ø25Refer to tables on next page
Port sizeThread type
F G
Rated voltage12345
100 VAC 50/60 Hz200 VAC 50/60 Hz110 VAC 50/60 Hz220 VAC 50/60 Hz
24 VDC
678JB
12 VDC240 VAC 50/60 Hz48 VAC 50/60 Hz230 VAC 50/60 Hz24 VAC 50/60 Hz
Bracket-B
NoneWith bracket
Built-in full-wave rectifier type
Solenoid valve optionFor list of options see table 1 next page
∗ N.O. for VXD2130 is not available.
DC/AC(Except VXD2130 AC/ClassB)for water and oil
• Wide selection of of body and seal materials for different fluids.• 4 body sizes, ports from 1/4" to 1".• with light and surge voltage suppressor available.• Normally closed and normally open versions.• Reduced power consumption (DC Specifications):
• IP65 Enclosure.• Low noise construction.• Flame resistant UL94V-0 conformed.
VXD21: 4.5W (VXD2140 to 2150) and 6W 5.5W (VXD2130)VXD22: 7W
Pilot Operated 2 Port Solenoid Valve for Air, Water and OilSeries VXD21/22
FeaturesFeatures
FeaturesSymbol
Electrical entryD -DIN terminal
DO -For Din without connector
∗ A surge voltage suppressor is integrated into the AC/Class B coil, as standard.
AC/Class B coil (Built-infull-wave rectifier type)
Connector
Alternative electricalentries
Please contact SMC for more details
Also available
Oil Free Expanded range ofbody materials
How to Order
FF
Series PF2A - Digital Flow Switch for Air - page 1309Series PF3W - Digital Flow Switch for Water - page 1317Series PA - Process Pump - page 1473Series ZSE/ISE�0A - Digital Pressure Switch for Air - page 1273Series ZSE/ISE80 - Digital Pressure Switch for Fluids - page 1290Series KQ2 - Fittings - page 1184Series TU - Tubing - page 1223
Related Products
Product Recommendation
Stocked items for fast delivery
VXD2130-02F-3DR1VXD2130-02F-4DR1VXD2130-02F-5D1VXD2130-02F-5DO1VXD2130-02F-BDR1VXD2130A-02F-5DO1VXD2130A-02F-BDOR1VXD2130-03F-3DR1VXD2130-03F-4DR1VXD2130-03F-5D1VXD2130-03F-BDR1
VXD2130-03F-JDR1VXD2130A-03F-5DO1VXD2130-04F-3DR1VXD2130-04F-4DR1VXD2130-04F-5D1VXD2130-04F-5DO1VXD2130-04F-BDOR1VXD2130-04F-BDR1VXD2130-04F-JDR1VXD2140-03F-5D1VXD2140-03F-5D1-B
VXD2140-03F-5DO1VXD2140-04F-3DR1VXD2140-04F-4DR1VXD2140-04F-5D1VXD2140-04F-5D1-BVXD2140-04F-5DO1VXD2140-04F-BDR1VXD2140-04F-JDOR1VXD2142-04F-JDR1VXD2140A-04F-5D1VXD2140A-04F-5DO1
VXD2140A-04F-JDR1VXD2150-06F-3DR1VXD2150-06F-4D1VXD2150-06F-4DR1VXD2150-06F-5D1VXD2150-06F-5D1-BVXD2150-06F-5DO1VXD2150-06F-BDO1VXD2150-06F-JDOR1VXD2152-06F-JDR1VXD2150A-06F-5D1
VXD2150A-06F-5DO1VXD2150A-06F-JDR1VXD2260-10F-3DR1VXD2260-10F-4DR1VXD2260-10F-5D1VXD2260-10F-5D1-BVXD2260-10F-5DO1VXD2260-10F-BDO1VXD2260-10F-BDR1VXD2260-10F-JDR1VXD2260A-10F-JDR1
®
Pilot Operated 2 Port Solenoid Valve – Series VXD21/22 1379
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
Body Material Options (Table 1) Operating Temperatures [ºC] (Table 2)
PowerSource —, G
ACDC
Air
-10 to 60
OilFluid/Body Material
Water
-10 to 60-5 to 60-5 to 60
1 to 601 to 60
A, H —, G, LAmbient
Temperature
-10 to 60-10 to 60
VXD2130VXD214 /215 VXD226
Model 5.5 4.5
7
Power consumption [W]504545
Temperature rise [ºC] Note)
DC Specification
VXD21VXD22
Model Apparent power [VA]5560
7 9.5
Temperature rise [ºC] Note)
AC Specification (Class B coil, built-in full-wave rectifier)
There is no difference in apparent power due to the inrush, energisation, orfrequency of the power, since the AC coil uses a rectifying circuit.
02
02
02
Valvespecifications
Coilspecifications
Valve constructionWithstand pressure [MPa]Body materialSeal materialEnclosureEnvironment
Rated voltage
Allowable voltage fluctuation
Coil insulation type
Allowable leakage voltage
Pilot operated 2 port diaphragm type8A to 25A: 5.0, 32A to 50A: 2.0
Brass (C37), Stainless steel, CAC407NBR, FKM, EPDM
Dusttight, Low jetproof (equivalent to IP65)Location without corrosive or explosive gases
24 VDC, 12 VDC10% of rated voltage
10% or less of rated voltage20% or less of rated voltage2% or less of rated voltage
Class B, Class H
AC (Class B coil, Built-in full-wave rectifier type)AC (Class B coil/H coil) Note 2)
DC (Class B coil only)
AC (Class B coil, Built-in full-wave rectifier type)AC (Class B coil/H coil) Note)
DC (Class B coil only)
Note) For the AC (Class B coil) of the VXD2130, built-in full-wave rectifier type is only applicable.
100 VAC, 200 VAC, 110 VAC, 220 VAC, 230 VAC,240 VAC, 48 VAC
Port size ModelOrifice size[mmø] AC DC
Max. operating pressuredifferential [MPa]
Min. operatingpressure
differential [MPa]101015101520
VXD2130-02VXD2130-03VXD2140-03VXD2130-04VXD2140-04VXD2150-06
0.9
1.00.9
1.0
0.02
0.7
1.00.7
1.0
Max. systempressure
[MPa]1/4 (8A)
3/8 (10A)
1/2 (15A)
3/4 (20A)
1.92.45.02.45.59.513
CvAv x 10-6m2
Flow characteristics
1.5
25 VXD2260-101 (25A)
Fluid andapplication
Air
Water
Heated water
Oil Note 2)
Optionsymbol
—G—GEPAHDN
Sealmaterial
NBR
NBR
EPDM
FKM
PPS
Body/Shadingcoil material
Push rod (N.O. only)material
Brass (C37)/–Stainless steel/–Brass (C37)/Cu
Stainless steel/AgBrass (C37)/Cu
Stainless steel/AgBrass (C37)/Cu
Stainless steel/AgBrass (C37)/Cu
Stainless steel/Ag
Coil insulationtype
B
B
H
B
H
Port size ModelOrifice size[mmø] AC, DC
Max. operating pressuredifferential [MPa]
Min. operatingpressure
differential [MPa]
15
2025
VXD2142-03VXD2142-04VXD2152-06VXD2262-10
0.60.02
Max. systempressure
[MPa]3/8 (10A)1/2 (15A)3/4 (20A)1 (25A)
110130230310
Av x 10-6m2
4.5 5.5 9.513
Cv converted
Flow characteristics
1.5
Standard Specifications
Solenoid Coil Specifications Note) The values are for an ambient temperature of 20ºC and at the rated voltage.
Normally Closed Specifications
Valve Specifications <Normally Open>
4658
11058
130230310
Series VXD21/22 – Pilot Operated 2 Port Solenoid Valve1380
Pro
cessV
alves
Normally closed (N.C.): VXD2140/2150/2260 Normally open (N.O.): VXD2142/2152/2262
ModelDIN terminal
Electrical entry (AC/Class B coil)
VXD2140VXD2150VXD2260
Normally closedVXD2142VXD2152VXD2262
Normally open
OUT IN
1
C
BA
K
e2 x ø8.5
d
Width acrossflats H
(D)L
1 (IN), 2 (OUT) port
G1/2
ø6 to ø12Cable
2 x P
T(4
4) 31.5
EV
U
M
IFJ
Model Port sizeP
3/8, 1/23/41
A
103.5 (110.5)115 (122)
133 (140.5)
VXD2140VXD2150VXD2260
N.C.VXD2142VXD2152VXD2262
N.O.B
242933
C
303035
D
638090
E
19.519.522.5
F
3.54.54.5
H
272732
I
141720
J
44.551.560
K
293743
L
344347
M
283542
Electrical entry
T63.5 (65)70 (71.5)84 (85.5)
V46.546.549.5
DIN terminalU
58.558.561.5
Model Port sizeP
3/8, 1/23/41
VXD2140VXD2150VXD2260
N.C.VXD2142VXD2152VXD2262
N.O.
Bracket mounting
( ) denotes the value for N.O.
( ) denotes the value for N.O.
T63.5 (65)70 (71.5)84 (85.5)
V53.553.556.5
U65.565.568.5
a425156
b667886
d577481
e345158
f39 45.549.5
OUTIN
G1/2
ø6 to ø12Cable
VU
31.5
(44)
KL(50)
T19.5
2 x P1 (IN), 2 (OUT) port
M40
B
30
A
Width acrossflats 27
Model Port sizeP
1/4, 3/81/2
A
80.586 VXD2130
N.C.B
11 14.5
K
2024
L
3026
M
2228
[mm]
Model Port sizeP
1/4, 3/81/2VXD2130
N.C.
Electrical entryDIN terminal
T5456
U58.558.5
V46.546.5
Dimensions VXD2130
Dimensions
[mm]
[mm][mm]
Pilot Operated 2 Port Solenoid Valve / Zero Differential Pressure Type – Series VXZ22/23 1381
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
• Choice of normally open and normally closed porting.• Five port size and 4 orifice size choices.• Oil free option available.• Suitable for air or a wide range of fluids.• DC and two AC coil options.• IP65 enclosure as standard.• Brass or stainless body material.
R
NRTL /C
The operating pressure differential is the difference in pressure between the inlet side of the valve and outlet side. In use this can vary between zero differential (eg 0.4MPa at both inlet and outlet sides) and a significant differential (example 0.7MPa on the inlet with the outlet open to atmosphere) The differential pressure tends to hold a two port valve closed.
The VX series shown in this catalogue are direct acting, so with larger orifice sizes the maximum operating pressure differential is limited by the ability of the coil to overcome the differential. Also shown in this catalogue is the VXD series. This has much larger orifice areas and actually uses the differential pressure to pilot assist the opening of the valve. Hence the VXD range has higher allowable maximum pressure differential but it is unable to function in a zero differential pressure situation.
The VXZ valves also have larger orifice size than the equivalent direct acting VX series, hence permitting a higher flow, without the penalty of restricted maximum operating pressure differential. A lift spring also permits correct operation even when the differential pressure falls to zero.
Brief explanation of zero operating pressure differential valves
Select body size, port size and orifice size using table 1. ØSelect body and seal options using table 2. ØCheck available Insulation class and coil type using table 2.
How to select VXZ Valves
Pilot Operated 2 Port Solenoid ValveFor Zero Pressure Differential OperationSeries VXZ22/23
FeaturesFeatures
Specifications
®
Series VXZ22/23 – Pilot Operated 2 Port Solenoid Valve / Zero Differential Pressure Type1382
Pro
cessV
alves
Threadtype
F G
Rated voltage12345
100 VAC 50/60 Hz200 VAC 50/60 Hz110 VAC 50/60 Hz220 VAC 50/60 Hz
24 VDC
678JB
12 VDC240 VAC 50/60 Hz48 VAC 50/60 Hz230 VAC 50/60 Hz24 VAC 50/60 Hz
Bracket-B
NoneWith bracket
∗ Bracket is not removable.
ModelRefer to the table (1)
shown below for availability. Orifice sizeRefer to the table (1) shown
below for availability.
Solenoid valve optionRefer to the table (2)shown below for availability.
Electrical entry
Port sizeRefer to the table (1)
shown below for availability.
D -DIN terminal
DO -For Din without connector
1 R102 DVXZ 3
5 102 DVXZDC 322
22 0
0
Built-in full-wave rectifier type
Valve/Body configuration02
N.C. / Single unitN.O. / Single unit
∗ A surge voltage suppressor is integrated into the AC/Class B coil, as standard.
AC/Class B coil (Built-infull-wave rectifier type)
Connector
F
F
Alternative electricalentries
Please contact SMC for more details
How to Order
Also available
Oil Free Expanded range ofbody materials
Product Recommendation
Stocked items for fast delivery
Series PF2A - Digital Flow Switch for Air - page 1309Series PF3W - Digital Flow Switch for Water - page 1317Series PA - Process Pump - page 1473Series ZSE/ISE�0A - Digital Pressure Switch for Air - page 1273Series ZSE/ISE80 - Digital Pressure Switch for Fluids - page 1290Series KQ2 - Fittings - page 1184Series TU - Tubing - page 1223
Related Products
VXZ2230-02F-3DR1VXZ2230-02F-4DR1VXZ2230-02F-5D1VXZ2230-02F-5DO1VXZ2230-02F-BDR1VXZ2230A-02F-5D1VXZ2232-02F-5D1VXZ2230-03F-3DR1VXZ2230-03F-4DR1VXZ2230-03F-5D1VXZ2230-03F-5D1-B
VXZ2230-03F-5DO1VXZ2230-03F-BDR1VXZ2230-03F-JDOR1VXZ2230-03F-JDR1VXZ2230A-03F-JDR1VXZ2232-03F-5D1VXZ2240-04F-3DR1VXZ2240-04F-4DOR1VXZ2240-04F-4DR1VXZ2240-04F-5D1VXZ2240-04F-5D1-B
VXZ2240-04F-5DO1VXZ2240-04F-5DO1-BVXZ2240-04F-BDR1VXZ2240-04F-JDOR1VXZ2240-04F-JDR1VXZ2240A-04F-5D1VXZ2240A-04F-JDR1VXZ2242-04F-4DR1VXZ2242-04F-5D1VXZ2242-04F-5DO1VXZ2350-06F-3DR1
VXZ2350-06F-4DR1VXZ2350-06F-5D1VXZ2350-06F-5DO1VXZ2350-06F-BDR1VXZ2350-06F-JDOR1VXZ2350-06F-JDR1VXZ2350A-06F-3DR1VXZ2350A-06F-5D1VXZ2352-06F-4DR1VXZ2352-06F-5D1VXZ2360-10F-3DR1
VXZ2360-10F-4DR1VXZ2360-10F-5D1VXZ2360-10F-5DO1VXZ2360-10F-BDR1VXZ2360-10F-JDOR1VXZ2360-10F-JDR1VXZ2360A-10F-5D1VXZ2360A-10F-5DO1VXZ2362-10F-5D1
Pilot Operated 2 Port Solenoid Valve / Zero Differential Pressure Type – Series VXZ22/23 1383
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
Valvespecifications
Coilspecifications
Valve construction
Withstand pressure [MPa]
Body material
Seal material
Enclosure
Environment
Vibration resistance/Impact resistance [m/s2]
Rated voltage
Allowable leakage voltage
Coil insulation type
Allowable voltage fluctuation
Zero differential pressure type pilot operated 2 port diaphragm type
5.0
Brass (C37), Stainless steel
NBR, FKM, EPDM
Dust - tight, Low jetproof (equivalent to IP65)
Location without corrosive or explosive gases
30/150 or less
100 VAC, 200 VAC, 110 VAC, 220 VAC, 230 VAC, 240 VAC, 48 VAC
24 VDC, 12 VDC
±10% of rated voltage
10% or less of rated voltage
20% or less of rated voltage
2% or less of rated voltage
Class B, Class H
AC (Class H coil)
DC (Class B coil only)
AC(Class B coil, Built-in full-wave rectifier type)
AC (Class H coil)
DC (Class B coil only)
AC(Class B coil, Built-in full-wave rectifier type)
Normally Closed (N.C.) / Normally Open (N.O.)Solenoid valve (Port size)
Model SealBodyVXZ22 VXZ23
Port no.(Port size)
NBRFKM
EPDM
Brass (C37),Stainless
steel
02 (1/4)03 (3/8)04 (1/2)
06 (3/4)10 (1)
Orifice symbol (Diameter) Material3
(10 mmø)4
(15 mmø)5
(20 mmø)6
(25 mmø)
Optionsymbol
—GEPAHDN
Valve sealmaterial
FKM
Valve bodymaterial
BrassStainless steelBrassStainless steelBrassStainless steelBrassStainless steel
Coilinsulation
type
B
H
Table (2) Standard Body Option
Table (1) Model - Orifice size - Port Size
Applicable to
B
Gases of water
Water
Oil
EPDM
NBR
H Hot water (AC only)
Tables
Common Specifications
Series VXZ22/23 – Pilot Operated 2 Port Solenoid Valve / Zero Differential Pressure Type1384
Pro
cessV
alves
VXZ22VXZ23
Model
7
10.5
Power consumption [W]
45
60
Temperature rise [ºC] Note)
DC Specification (Class B coil only)
Note 1) The value at ambient temperature of 20ºC and when the rated voltage is applied.
Note 2) There is no difference in the frequency and the inrush and energised apparent power, since a rectifying circuit is used in the AC spec.
(Class B coil, Built-in full-wave rectifier type).
VXZ22VXZ23
Model
9.5
12
Apparent power (VA) Note 2)
60
65
Temperature rise [ºC] Note 1)
AC Specification (Class B coil, Built-in full-wave rectifier type)
Note) The value at ambient temperature of 20ºC and when the rated voltage is applied.
Solenoid Coil Specifications
Port size(Nominal
size)
Min. operatingpressure
differential [MPa]Orifice size
[mmø] ModelDCAC
Max. operating pressuredifferential [MPa]
Max. systempressure
[MPa]Weight [g]
10
1520
VXZ2230-02VXZ2230-03VXZ2240-04VXZ2350-06
1.5 550
7601300
0.71.00
Note) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
8.511.023.038.0
C0.440.420.340.20
b2.42.86.09.5
Cv
Flow characteristics
Normally Closed (N.C.)
1/4 (8A)3/8 (10A)1/2 (15A)3/4 (20A)
Port size(Nominal
size)
Min. operatingpressure
differential [MPa]Orifice size
[mmø] ModelDCAC
Max. operating pressuredifferential [MPa]
Max. systempressure
[MPa]Weight [g]
25 VXZ2360-10 1.5 14800.71.00 215Effective area [mm2]
Flow characteristics
1 (25A)
Note) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
Port size(Nominal
size)
Min. operatingpressure
differential [MPa]Orifice size
[mmø] ModelDCAC
Max. operating pressuredifferential [MPa]
Max. systempressure
[MPa]Weight [g]
25 VXZ2362-10 1.5 15500.60.70 215Effective area [mm2]
Flow characteristics
1 (25A)
Port size(Nominal
size)
Min. operatingpressure
differential [MPa]Orifice size
[mmø] ModelDCAC
Max. operating pressuredifferential [MPa]
Max. systempressure
[MPa]Weight [g]
10
1520
VXZ2232-02VXZ2232-03VXZ2242-04VXZ2352-06
1.5 600
8501370
0.7 0.60
8.511.023.038.0
C0.440.420.340.20
b2.42.86.09.5
Cv
Flow characteristics
Normally Open (N.O.)
1/4 (8A)3/8 (10A)1/2 (15A)3/4 (20A)
Power source
AC/Class B coilDC
Ambienttemperature
[ºC]–10 to 60–10 to 60
-, G
Fluid temperature [ºC]Solenoid valve option symbol
–10 to 60 Note)
–10 to 60 Note)
NBRSeal material Leakage rate (Air)
1 cm3/min or less
Note) Dew point temperature: –10ºC or less.
Internal Leakage
NBRSeal material Leakage rate (Air)
1 cm3/min or less
External Leakage
Gases Specifications
Ambient and Fluid Temperature Valve Leakage Rate
Pilot Operated 2 Port Solenoid Valve / Zero Differential Pressure Type – Series VXZ22/23 1385
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
Port size(Nominal
size)
Min. operatingpressure
differential [MPa]Orifice size
[mmø] ModelDCAC
Max. operating pressuredifferential [MPa]
Max. systempressure
[MPa]Weight [g]
10
152025
VXZ2230-02VXZ2230-03VXZ2240-04VXZ2350-06VXZ2360-10
1.5
550
76013001480
0.70
Note) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
4658
130220290
Av x 10-6m2
1.9 2.4 5.3 9.212.0
Cv converted
Flow characteristics
Normally Closed (N.C.)
1/4 (8A)3/8 (10A)1/2 (15A)3/4 (20A)1 (25A)
Port size(Nominal
size)
Min. operatingpressure
differential [MPa]Orifice size
[mmø] ModelDCAC
Max. operating pressuredifferential [MPa]
Max. systempressure
[MPa]Weight [g]
10
152025
VXZ2232-02VXZ2232-03VXZ2242-04VXZ2352-06VXZ2362-10
1.5
600
85013701550
0.7 0.60
Note) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
4658
130220290
Av x 10-6m2
1.9 2.4 5.3 9.212.0
Cv converted
Flow characteristics
Normally Open (N.O.)
1/4 (8A)3/8 (10A)1/2 (15A)3/4 (20A)1 (25A)
Power source
AC/Class B coilAC/Class H coil
DC
Ambienttemperature
[ºC]–10 to 60–10 to 60–10 to 60
A, H
Fluid temperature [ºC]Solenoid valve option symbol
–5 to 60—
–5 to 60
D, N—
–5 to 100—
FKMSeal material Leakage rate (Oil)
0.1 cm3/min or less
Note) Kinematic viscosity: 50 mm2/s or less
Internal Leakage
FKMSeal material Leakage rate (Oil)
0.1 cm3/min or less
External Leakage
Oil Specifications
Ambient and fluid Specifications Valve Leakage Rate
Port size(Nominal
size)
Min. operatingpressure
differential [MPa]Orifice size
[mmø] ModelDCAC
Max. operating pressuredifferential [MPa]
Max. systempressure
[MPa]Weight [g]
10
152025
VXZ2230-02VXZ2230-03VXZ2240-04VXZ2350-06VXZ2360-10
1.5
550
76013001480
0.71.00
1.0
Note) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
4658
130220290
Av x 10-6m2
1.9 2.4 5.3 9.212.0
Cv converted
Flow characteristics
Normally Closed (N.C.)
1/4 (8A)3/8 (10A)1/2 (15A)3/4 (20A)1 (25A)
Port size(Nominal
size)
Min. operatingpressure
differential [MPa]Orifice size
[mmø] ModelDCAC
Max. operating pressuredifferential [MPa]
Max. systempressure
[MPa]Weight [g]
10
152025
VXZ2232-02VXZ2232-03VXZ2242-04VXZ2352-06VXZ2362-10
1.5
600
85013701550
0.7 0.60
Note) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
4658
130220290
Av x 10-6m2
1.9 2.4 5.3 9.212.0
Cv converted
Flow characteristics
Normally Open (N.O.)
1/4 (8A)3/8 (10A)1/2 (15A)3/4 (20A)1 (25A)
Power source
AC/Class B coilAC/Class H coil
DC
Ambienttemperature
[ºC]–10 to 60–10 to 60–10 to 60
-, G, L
Fluid temperature [ºC]Solenoid valve option symbol
1 to 60—
1 to 60
E, P—
1 to 99—
NBR, FKM, EPDMSeal material Leakage rate (Water)
0.1 cm3/min or less
Note) With no freezing
Internal Leakage
NBR, FKM, EPDMSeal material Leakage rate (Water)
0.1 cm3/min or less
External Leakage
Water Specifications
Ambient and Fluid Temperature Valve Leakage Rate
Series VXZ22/23 – Pilot Operated 2 Port Solenoid Valve / Zero Differential Pressure Type1386
Pro
cessV
alves
Normally closed (N.C.): VXZ21�0/VXZ22�0/VXZ23�0Normally open (N.O.): VXZ21�2/VXZ22�2/VXZ23�2
DIN terminal: DGrommet: G
OUTIN
L
MN
44 31.5
Cableø6 to ø12
G1/2
Bracket
Model
Na b d e f g h i
77.5 85.5 97.5104
52606873
67758792
14172222
1.62.32.62.6
26 33 40 45.5
5.56.56.56.5
7.58.59 9
28354345
Q33333636
N 73.5 81.5 93.5100
Q68.568.571 71
R56.556.559 59
Grommet DIN terminalElectrical entry (AC/Class B coil)∗
Port sizeP
1/4, 3/81/23/41/1
VXZ2230VXZ2240VXZ2350VXZ2360
N.C.VXZ2232VXZ2242VXZ2352VXZ2362
N.O.
[mm]
∗ Coil with built-in full-wave rectifier (electrical option “R”)
Model
LA B C D E F H J K
81.5 (83)89.5 (91)
101.5 (103.5)108 (109)
11141821
90 (97)98 (105)
110 (117.5)116.5 (123)
35354040
50638090
22.522.525 25
30 37 47.555
20 26 32.535
22 29.536 40.5
40526570
M22.522.525.525.5
L73.5 (75)81.5 (83)
93.5 (95.5)100 (101)
M61.561.564 64
N49.549.552 52
Grommet DIN terminalElectrical entry (DC, AC/Class H coil)
Port sizeP
1/4, 3/81/23/41/1
VXZ2230VXZ2240VXZ2350VXZ2360
N.C.VXZ2232VXZ2242VXZ2352VXZ2362
N.O.
[mm]
( ) denotes the value for N.O.
OUTIN
dL A
b
(D)
i
KJ
e
F H
Bg
h
a
300 M E C
Bracket
2-PPort size
f
Dimensions/Body Material: Brass, Stainless Steel
Direct Operated 2 Port Solenoid Valve – Series VX21/22/23 1387
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
• Special body materials: Aluminium and Resin bodies can be selected in the valve for air. Brass C37 and stainless steel bodies are available in the rest of the types.• Compact and lightweight• Low power consumption: 4.5 W in size 1; 7.0 W in size 2 and 10.5 W in size 3 (about half of the consumption of the competence’s valves).• Low-noise construction: the noise of the valve during its operation has been reduced by incorporating a rubber bumper.• Large flow rate.
Direct Operated 2 Port Solenoid ValveSeries VX21/22/23
Features
Symbol
How to Order
SSSSSyyyS mmmmbbbooll2
1
Symbol
1
Size Valvetype
Size 1
2 Size 2
3 Size 3
SingleunitN.C.
SingleunitN.C.
SingleunitN.C.
Symbol
ABCDEFHJKLMN
ABDEHJLM
ABCDEFGHJKLMNP
Bodymaterial
C37(Brass)
Stainlesssteel
C37(Brass)
Stainlesssteel
C37(Brass)
Stainlesssteel
Orificediameter
47474747
58
1058
101058
1058
1010
235235235235
Port size
1/4
3/8
1/2
1/4
3/8
1/2
1/4
3/8
1/4
3/8
1/8
1/4
1/8
1/4
VX2 2 A A1
Fluid234
For waterFor oil
For medium vacuum
Size/Valve type Body material/Port size/Orifice diameter/Pressure
Voltage/Electrical entrySymbol
A
Z1UCEFGJL
Z1V
Y
Electrical entryVoltage
DIN terminal without DIN connector
Note) Vacuum model used with vacuum (Pa·abs), operating pressure range: 0.1 to atmospheric pressure.
Note) Oil model is FKM as standard.Vacuum model is FKM and Oil-free as standard
Z3A
Z3C
Z3E
Z3V
24 VDC
110 VAC
230 VAC
24 VAC
24 VDC
24 VAC
110 VAC
230 VAC
24 VDC
24 VDC
110 VAC
230 VAC
24 VAC
24 VDC
Faston terminal
Grommet
Grommet
DIN terminal
With surge voltage suppressor
With surge voltage suppressor
Max. operatingpressure
diff. [Mpa] Note)
1.00.60.21.00.60.21.00.60.21.00.60.2
1.00.30.11.00.30.10.11.00.30.11.00.30.10.1
1.00.151.0
0.151.0
0.151.0
0.15
A
Oil-free spec.–Thread type
Symbol
ADFK
Threadtype
Seal materialFKM—
—
G
G
G
G
Oil-free spec.
—
—
Bracket
With interchangeable bracketwith old VX21/22/23 Series
Without interchangeable bracketwith old VX21/22/23 Series—
XB
XB
Series VX21/22/23 – Direct Operated 2 Port Solenoid Valve1388
Pro
cessV
alves
How to Order
Specifications
Related Products
Series PF2A - Digital Flow Switch for Air - page 1309Series PF3W - Digital Flow Switch for Water - page 1317Series PA - Process Pump - page 1473Series ZSE/ISE�0A - Digital Pressure Switch for Air - page 1273Series ZSE/ISE80 - Digital Pressure Switch for Fluids - page 1290Series KQ2 - Fittings - page 1184Series TU - Tubing - page 1223
Symbol
1
Size Valvetype
Size 1
2 Size 2
3 Size 3
SingleunitN.C.
SingleunitN.C.
SingleunitN.C.
Symbol
ABCDEFHJKLMN
ABDEHJLM
ABCDEFGHJKLMN
Bodymaterial
Orificediameter
47474747
581058101058105810
235235235235
Port size
VX2 0 A A1Fluid
0 For air
Size/Valve type Body material/Port size/Orifice diameter/Pressure
Voltage/Electrical entrySymbol
A
Z1UCEFGJL
Z1V
Y
Electrical entryVoltage
DIN terminal without DIN connector
Z3A
Z3C
Z3E
Z3V
24 VDC
110 VAC
230 VAC
24 VAC
24 VDC
24 VAC
110 VAC
230 VAC
24 VDC
24 VDC
110 VAC
230 VAC
24 VAC
24 VDC
Faston terminal
Grommet
Grommet
DIN terminal
With surge voltage suppressor
With surge voltage suppressor
Seal material – Oil-free spec.–Thread type
Symbol
ADFK
Thread typeSeal materialFKM—
—
G
G
G
G
Max. operatingpressure
diff. [Mpa] Note)1.00.60.21.00.60.21.00.60.21.00.60.2
1.00.30.11.00.30.10.11.00.30.11.00.30.1
1.00.151.00.151.00.151.00.15
A
Aluminium
Resin
Aluminium
Resin
Aluminium
Resin
1/8
1/4
ø6 one-touch fitting
ø8 one-touch fitting
1/4
3/8
1/2
ø10 one-touch fitting
ø12 one-touch fitting
1/4
3/8
ø8 one-touch fitting
ø10 one-touch fitting
Valv
esp
ecifi
catio
nsC
oil
spec
ifica
tions
Valve construction
Note 1) Electrical entry "Faston" type terminal is IP40.Note 2) Voltage in ( ) indicates special voltage.
Withstand pressureBody materialSeal materialEnclosureEnvironment
Rated voltage
Allowable voltage fluctuationCoil insulation type
Direct operated poppet2.0 (resin body type 1.5)Aluminium, Resin, C37 (Brass), Stainless steelNBR, FKMDusttight, Low jetproof (IP65) Note 1)
Location without corrosive or explosive gases110 VAC, 230 VAC, 24 VAC (220 VAC, 240 VAC, 48 VAC) Note 2)
24 VDC (12 VDC) Note 2)
±10% of rated voltage
Class B
AC
DC
Oil-free spec.
—
—
Fluid and Ambient Temperature
Note 1) Dew point temperature: –10°C or less , Note 2) With no freezingNote 3) Kinematic viscosity: 50mm2/s or less
Fluid Ambient temperature [°C]Fluid temperature [°C]Air
Water, VacuumOil
-20 to 60-20 to 60-20 to 60
-10 to 601 to 60
-5 Note 3) to 60
Product Recommendation
Stocked items for fast delivery
VX212AGAXBVX212BGAXBVX212CGAXBVX212EFAXBVX212EGAXB
VX212ELAXBVX212EZ1VAXBVX212MGAXBVX222AGAXBVX222AJAXB
VX222DGAXBVX222EFAXBVX232DGAXBVX213AGAXBVX213EZ3VAXB
VX213MGAXBVX223AGAXBVX214CGAXBVX214EGAXB
Direct Operated 2 Port Solenoid Valve – Series VX21/22/23 1389
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
Air- Model/Valve Specifications
Medium Vacuum- Model/Valve Specifications
Port sizeSize Orifice diameter[mmø] Model
Maximum operatingpressure differential
[MPa]1.0 0.6 0.2 1.0 0.151.0 0.3 0.1 0.1
2 3 5 4 7 5 81010
1/8, 1/4
1/4, 3/8
1/4, 3/8
1/2
1
2
3
0.230.410.620.621.080.751.582.212.21
220220220340340450450450470
0.630.680.390.520.440.550.330.640.39
0.631.052.201.903.991.965.675.748.42
C [dm3/[s·bar]] b Cv
Flow-rate characteristics
Note) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
Normally Closed (N.C.)AIuminum Body Type
VX210
VX220
VX230
VX210
VX220
VX230
Port sizeSize Orifice diameter[mmø] Model
Maximum operatingpressure differential
[MPa]1.0 0.6 0.2 1.0 0.6 0.2 1.0 0.151.0 0.151.0 0.3 0.1 1.0 0.3 0.1
0.821.251.450.821.812.111.693.141.683.542.502.775.692.502.565.69
2 3 5 2 3 5 4 7 4 7 5 810 5 810
C6
C8
C8
C10
C10
C12
1
2
3
C [dm3/[s·bar]] b Cv
Flow-rate characteristicsResin Body Type (Built-in One-touch Fittings)
Weight Note)
[g]
Weight Note)
[g]
0.440.340.430.440.400.320.400.340.490.360.440.820.460.440.880.64
0.230.350.400.230.410.560.470.840.500.900.701.221.540.701.381.76
220220220220220220340340340340460460460460460460
Note) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
Normally Closed (N.C.)
Port sizeSizeOrifice
diameter[mmø]
ModelOperating pressure range
q Used withvacuum [Pa·abs]
w Used withpressure [MPa]
0.1 toatmospheric
pressure
2 3 5 4 7 5 81010
1/8, 1/4
1/4, 3/8
1/4, 3/8
1/2
1
2
3
C [dm3/[s·bar]] b
0.230.410.620.621.080.751.582.212.21
0.630.680.390.520.440.550.330.640.39
0.631.052.201.903.991.965.675.748.42
Cv
Flow-rate characteristics
VX214
VX224
VX234
220220220340340450450450470
0 to 1.00 to 0.60 to 0.20 to 1.00 to 0.150 to 1.00 to 0.30 to 0.10 to 0.1
Weight[g]
Note)
Series VX21/22/23 – Direct Operated 2 Port Solenoid Valve1390
Pro
cessV
alves
Water- Model/Valve Specifications
Oil- Model/Valve Specifications
Accessories
Note) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
Normally Closed (N.C.)
Port sizeSize Orifice diameter[mmø] Model
Maximum operatingpressure differential
[MPa]10.60.210.1510.30.10.1
2 3 5 4 7 5 81010
1/8, 1/4
1/4, 3/8
1/4, 3/8
1/2
1
2
3
AV0.230.420.630.631.080.751.582.212.21
Conversion Cv
Flow-rate characteristics
VX213
VX223
VX233
Weight Note)
[g]
5.510.015.015.026.018.038.053.053.0
300300300460460580580580630
Note) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
Normally Closed (N.C.)
Port sizeSize Orifice diameter[mmø] Model
Maximum operatingpressure differential
[MPa]1 0.6 0.2 1 0.151 0.3 0.1 0.1
300300300460460580580580630
2 3 5 4 7 5 81010
1/8, 1/4
1/4, 3/8
1/4, 3/8
1/2
1
2
3
AV
5.510.015.015.026.018.038.053.053.0
0.230.420.630.631.080.751.582.212.21
Conversion Cv
Flow-rate characteristics
VX212
VX222
VX232
Weight Note)
[g]
The brackets are interchangeable with brackets of old VX21/22/23 series.For details of exterior dimensions, please contact SMC.∗ Only for C37 (Brass) and stainless steel
Select brass (C37), in the type “for Water”, when interchangeable product is necessary for air.
Bracket interchangeablewith old type
VX XB
Enter standardproduct number.
Bracket interchangeablewith old type
DIN Connector Part No.
C18312G6GCUGDM2A
Without electrical option
With electrical option (light)
1256
15
Rated voltage100 VAC, 110 VAC
24 VDC12 VDC48 VAC
200 VAC, 220 VAC 230 VAC, 240 VAC
LElectrical option
With light
L
Gasket for DIN Connector: VCW20-1-29-1
Lead Wire Assembly for Faston Terminal (Set of 2 pcs.): VX021S-1-16FB
Direct Operated 2 Port Solenoid Valve – Series VX21/22/23 1391
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
Dimensions
D
2 x PPort size
A
Q F
BB1
≈ 300
CRE
D
CRE
A2 x PPort size
Cable ø6 to ø12
G1/2
QS
F
B1
B
2 x PPort size
A
ECR
Q F11
BB1
119
6.5
15
D
D
CRE
A2 x PPort size
Q F
B1
B
≈ 300
Body Material: Aluminium
DIN terminal
Grommet (with surge voltage suppressor)
Faston type
Terminal partFaston connector
250 Series
Grommet (DC)
Size Port sizeP
Electrical entry
64.567 69.569.5
Q34455053
R52.555 57.557.5
S23 25.528 28
Q42 53.558 61
R12
3
1/8, 1/41/4, 3/81/4, 3/8
1/2
Size Port sizeP A
19242430
B
43454550
D
30354040
E
9.512 12 15
F
20 22 24.524.5
Q27 29.532 32
R42 53.558 61
B1 C
21 22.522.525
61 76 81 86.5
Grommet
DIN terminal Faston type
Electrical entry
12
3
1/8, 1/41/4, 3/81/4, 3/8
1/2
[mm]
30 32.535 35
Q28.539.544.547.5
R
Grommet (withsurge voltagesuppressor)
Series VX21/22/23 – Direct Operated 2 Port Solenoid Valve1392
Pro
cessV
alves
Body Material: Resin
XX1
YW
UU
1
B1
B
≈ 300 Q F D
ECR
2 x PPort size
XX1
YW
UU
1
BB1
FQS
ECR
D
2 x PPort size
Cable ø6 to ø12
G1/2
2 x ø3.4Mountinghole
2 x ø3.4Mountinghole
≈ 300 Q
B1
B
F
CRE
D
2 x PPort size
Y2 x ø3.4Mountinghole
W
XX1
UU
1
Grommet
DIN terminal Conduit terminal
Grommet (with surge voltage suppresor)
Size One-touch fittingP B
53.566 68
B1293637
E13.515 16.5
F20 22 24.5
U W X1455358
222731
26 31 33.5
U1 X Y22.526.529
526267
303540
C D65.576.584
303540
Mounting bracket dimensions
123
C6, C8C8, C10
C10, C12
[mm]
Size One-touch fittingP
Electrical entry
27 29.532
Q42.551 56.5
R30 32.535
Q293743
R
GrommetGrommet (withsurge voltagesuppressor)
64.567 69.5
Q34.543 48.5
52.555 57.5
R S
DIN terminal
123
C6, C8C8, C10
C10, C12
Dimensions
Direct Operated 2 Port Solenoid Valve – Series VX21/22/23 1393
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
6.5
15
911
YW
UU
1
XX1
B1
B
11 Q F DE
CR
2 x PPort size
2 x ø3.4Mountinghole
Size Mounting bracket dimensionsOne-touch fittingP
U455358
U122.526.529
X126 31 33.5
Y303540
Q23 25.528
R42.551 56.5
W X222731
526267
Faston typeElectrical entry
123
C6, C8C8, C10C10, C12
[mm]
53.566 68
293637
13.515 16.5
20 22 24.5
B B1 E FC D
65.576.584
303540
Faston type
Terminal partFaston connector
250 Series
Body Material: Resin
Dimensions
Series VX21/22/23 – Direct Operated 2 Port Solenoid Valve1394
Pro
cessV
alves
Body Material: C37 (Brass), Stainless Steel
D
CRE
A2 x PPort size
≈ 300 Q F
B1
B
Cable ø6 to ø12
G1/2D
CRE
A2 x PPort size
QS
F
B1
B
D
CR
E
A
≈ 300 Q F
B1
B 2 x PPort size
Grommet
DIN terminal
Size Port sizeP
Electrical entry
27 29.532 32
Q42 53.557.561
R30 32.535 35
Q28.539.544 47.5
R
GrommetGrommet (withsurge voltagesuppressor)
64.567 69.569.5
Q34 45 49.553
R52.555 57.557.5
S
DIN terminal
123
1/8, 1/41/4, 3/81/4, 3/8
1/2
[mm]
19 22 22 29.5
43454550
30354040
9.510.510.514
20 22 24.524.5
A B D E FB1 C
21 22.522.525
61 74.579 85.5
Grommet (with surge voltage suppressor)
Dimensions
Direct Operated 2 Port Solenoid Valve – Series VX21/22/23 1395
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
Body Material: C37 (Brass), Stainless Steel
DCR
E
A
119
6.5
15
11 Q F
B1
B 2 x PPort size
Faston type
Terminal partFaston connector
250 Series
Size Port sizeP
Electrical entry
23 25.528 28
Q42 53.557.561
RFaston type
123
1/8, 1/41/4, 3/81/4, 3/8
1/2
[mm]
A
19 22 22 29.5
43454550
30354040
9.510.510.514
20 22 24.524.5
B D E FB1 C
21 22.522.525
61 74.579 85.5
Dimensions
Series VNB – Air Operated 2 Port Valve for General Use1396
Pro
cessV
alves
• External pilot solenoid option.• Robust poppet construction.• Wide variety of suitable fluids, due to body and seal options.• Sizes from 1/8" to 2".• NC, NO, CO porting options.
2 Port Valve for Flow Control - Process ValveSeries VNB
Features
Symbol
How to Order
SymbolsValvetypeType
Air operated
N.C. N.O. C.O.Normally closed Normally open Double acting
VNB0 VNB02 VNB0314
12 (P1)
2 (B)
1 (A)
10 (P2)
2 (B)
1 (A)
12 (P1)
10 (P2)
2 (B)
1 (A)
ValvetypeType
Air operated
N.C.Normally closed
N.O.Normally open
VNB01V VNB02V10
(P2)
2 (B)
1 (A)
12 (P1)
2 (B)
1 (A)
Symbols (Vacuum pilot type)
15AAir operated 2 1 A F0EVNBEVNB
15A2 1 A F 1 QD1
Seal material
Valve size
ABC
NBR sealsFKM sealsEPR seals
Thread typeF G ported
Body optionStandard
Vacuum pilotStainless steel body
—V∗SL Aluminum body
Valve type Port size
Orificesize
[mm]…Symbol
G
Symbol
Symbol
1
N.C.0.5 MPa N.O. C.O.
Portsize
ø7
ø11ø15ø11
1
1 2 3 Note)
N.C.1 MPa
4
2
ø15ø14
3 ø20ø16ø254
ø225ø32ø28ø40
6
2ø33
7
1 81 43 8
3 8
1 2
3 4
11 4
6A8A
10A
10A
15A
20A
25A
32A
50A
40A 11 2
———— — —
——
—
—
—
—
—
—
—
—
—
—
—
—
—
——
—
—
—
—
—
——
—
(∗) Symbol V is for vaccuum pilot valve specification, for both main pressure and pilot pressure, valve size 2 to 7.
110V AC 50/60Hz2 200V AC 50/60Hz1
D
100V AC 50/60Hz
220V AC 50/60Hz24V DC12V DC
240V AC 50/60Hz
Rated voltage
345679
Electrical entryDIN connector
Other: Less than 250 VAC and 50 VDC
External pilot solenoid
ø50
Air Operated 2 Port Valve for General Use – Series VNB 1397
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
Specifications Model
Valve specifications
Valve specifications
Product Recommendation
Stocked items for fast delivery
EVNB102B-F8AEVNB104A-F8AEVNB104B-F8AEVNB104BS-F8AEVNB114A-F8A-5D-QEVNB102AS-F10AEVNB104A-F10AEVNB104AS-F10AEVNB114A-F10A-5D-QEVNB201A-F10AEVNB201B-F10AEVNB204A-F10A
EVNB204B-F10AEVNB214A-F10A-5D-QEVNB201A-F15AEVNB201AS-F15AEVNB201B-F15AEVNB201BS-F15AEVNB202A-F15AEVNB202AS-F15AEVNB202B-F15AEVNB204A-F15AEVNB204AS-F15AEVNB204B-F15A
EVNB204BS-F15AEVNB211A-F15A-5D-QEVNB214A-F15A-5D-QEVNB301A-F20AEVNB301B-F20AEVNB302AS-F20AEVNB304A-F20AEVNB304AS-F20AEVNB304B-F20AEVNB311A-F20A-5D-QEVNB314A-F20A-5D-QEVNB401A-F25A
EVNB401AS-F25AEVNB401B-F25AEVNB401BS-F25AEVNB402A-F25AEVNB402B-F25AEVNB404A-F25AEVNB404AS-F25AEVNB404B-F25AEVNB411A-F25A-5D-QEVNB414A-F25A-5D-QEVNB501A-F32AEVNB501B-F32A
EVNB601A-F40AEVNB602B-F40AEVNB604A-F40AEVNB604B-F40AEVNB611A-F40A-5D-QEVNB614A-F40A-5D-QEVNB701A-F50AEVNB701B-F50AEVNB704A-F50AEVNB704B-F50AEVNB711A-F50A-5D-QEVNB714A-F50A-5D-Q
Related Products
Series V100 - Valves - page 353Series SYJ300/500/700 - Valves - page 369Series PF2A - Digital Flow Swith for Air- page 1309 Series PF3W - Digital Flow Swith for Water - page 1317 Series PA - Process Pump - page 1473Series ZSE/ISE0A - Digital Pressure Switch for Air - page 1273Series ZSE/ISE80- Digital Pressure Switch for Fluids - page 1290Series KQ2 - Fittings - page 1184Series TU - Tubing - page 1223
1 81 4
3 8
1 2
3 4
1 4
1 2
1
1
VNB1���-6AVNB1���-8AVNB1���-10AVNB2�4�-10AVNB2���-10AVNB2�4�-15AVNB2���-15AVNB3�4�-20AVNB3���-20AVNB4�4�-25AVNB4���-25AVNB5�4�-32AVNB5���-32AVNB6�4�-40AVNB6���-40AVNB7�4�-50AVNB7���-50A
7
1115111514201625223228403350 42204.50
28463.5027482.018648.5017667.010796.5011778.06870.507852.004907.504907.502944.503729.702453.751275.95981.50687.05
77052050033032021022013014090905570452318 0.3
0.6
0.9
1.4
2.5
4.1
6.3
0.4
0.7
1.0
1.5
2.6
4.2
6.4
13
2
1
Model Port sizeOrifice
sizeø [mm] [Nl/min]
Flow rateEffective area
[mm2]
Weight [kg]Air
operatedExternal pilot
solenoid
1 to 400 Torr1 to 760 Torr
VacuumFluidPressure rangePilot pressure range
Option SpecificationsVacuum pilot valve VNB V(Valve size 2 to 7) It is used when the valve is to be operated by the main vacuum in the absence of pressurized air.
–5 to 60°C (1)
1.5MPaLow vacuum to 0.5MPaLow vacuum to 1MPa
0.25 to 0.7MPa0.1 to 0.5MPa
–5 to 50°C (Air operated: 60°C) (1)
Unrestricted (4)
–5 to 99°C (1)VNB���A
VNB��1�VNB�� �
VNB��� BC
234
VNB�� �14
VNB�� �23
Fluids Water, Oil, Air, Vaccum, etc.
Fluidtemperature
Ambient temperature Proof pressureApplicable press. range (3)
External pilot air
(Water, oil etc. Only air operated)–5 to 50°C(Air operated type: 60°C) (1)
Not required (Use turbine oil No.1 (ISO VG32), if lubricated.) (2)
Note 1) No freezingNote 2) Lubrication is not allowed in case of seal material EPR.Note 3) The pressure differential between Port 1 (A) and 2 (B) must not exceed the maximum operating pressure.Note 4) For external pilot solenoid, it is recommended that the pilot solenoid valve be oriented either vertically upward or horizontally.
Press.
LubricationTemperature
Mounting orientation
Series VNB – Air Operated 2 Port Valve for General Use1398
Pro
cessV
alves
Dimensions
Pilot Solenoid Specifications
SF4-���-23
DC
AC
100V, 110V, 200V, 220V, 280V12V, 24V
5.6VA(50Hz), 5.0VA(60Hz)
1.8W 4.8W
6A to 25A 32A to 50AVO307�-DZ-Q
Port sizePilot solenoid valveElectrical entryCoil ratedvoltage
AC (50/60Hz)DC
Allowable voltageCoil insulation
Temperature rise
Manual override
Apparent power
Power consumption
InrushHolding
DIN connector DIN connector
–15% to +10%of rated voltageClass B or equivalent (130°C)
≤35°C (Application ofrated voltage)
≤70°C (Application ofrated voltage)
3.4VA(50Hz), 2.3VA(60Hz)
Non-locking push styleOthers (Option)
12VA(50Hz), 10.5VA(60Hz)7.5VA(50Hz), 6VA(60Hz)
Non-locking push style
Model
VNB100-F6AVNB100-F8AVNB100-F10A
Main port
1 81 43 8
Port size 6A, 8A, 10AStandard
Specifications
Air Operated 2 Port Valve for General Use – Series VNB 1399
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
Port size 10A, 15A, 20A, 25AStandard
Port size 10A, 15A, 20A, 25AVacuum Pilot
VNA2���-F10AVNA2���-F15AVNA3���-F20AVNA4���-F25A
Main Port AModel
63
8090
B
42
5060
C
28
3540
D
14
17.520
E
72.5
84100
F
80.5
92108
I
82.5
91.597.5
L
142.5
154170
M
52
6272
N
26
3136
P
4.5
5.56.5
Q
24.3
28.333.3
R
2.3
2.32.3
S
25
3035
T
34
4349
U
55
60.5731
3 81 23 4
VNA5���-F32AVNA6���-F40AVNA7���-F50A
Main Port Pilot port A
105120140
B
7796
113
C
536074
D
26.53037
E
120.5137160
F
202424
G
129.5147170
J
219.5237260
M
556374
1 411 212
1 81 41 4
Model Rc(PT)
Dimensions
Series VNB – Air Operated 2 Port Valve for General Use1400
Pro
cessV
alves
Port size 32A, 40A, 50AStandard/ Vacuum Pilot
A
105120140
B
7796
113
C
536074
D
26.53037
E
120.5137160
F
202424
G
129.5147170
J
219.5237260
M
556374
1 41 2
11
2
1 81 41 4
VNB5����-32AVNB6����-40AVNB7����-50A
Pilot portRc(PT)Model Main port
Dimensions
Air Operated 2 Port Valve For Steam – Series VND 1401
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
• Temperatures up to 180ºC are possible.• PTFE seals as standard.• Seven body sizes, ports from 1/8" to 2".• Choice of brass or stainless body material.• Functions NO and NC can be chosen.• Air pilot operated robust poppet design.• High flow capacities.
EVND 15AAir operated 2 D S F0Valve type
Body option—S
StandardStainless steel body
Valve size Port size
Orifice size[mm]Symbol
SymbolSymbol
11
N.C. N.O. N.C.
Portsize [G]
2
1
0 2 4
345
ø15
ø7
ø20ø25ø32ø40ø50
627
6A8A
10A10A15A20A25A32A40A50A
1 81 43 83 81 23 4
1 411 2
–––
–––––––
Valve typeValve size
N.C. N.O.Normally closed Normally open
VND1
VND 234567
12 (P1)
1 (A)
2 (B)
10 (P2)
1 (A)
2 (B)
10 (P2)
1 (A)
2 (B)
12 (P1)
1 (A)
2 (B)
0
Steam Valve: 2 Port Valve For SteamSeries VND
FeaturesFeatures
How to Order
Symbols
Valve BodySize
1234
Mounting BracketAssemblies
VN1-16VN2-16VN3-16VN4-16
FluidFluid temperatureAmbient temperatureProof pressure Operating pressure range
Externalpilot air
Steam–5 to 180ºC No Freezing–5 to 60ºC No Freezing
1.5 MPa0 to 0.97 MPa0.3 to 0.7 MPa
Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)–5 to 60ºC ∗
PressureN.C.
N.O.
LubricationTemperature
0.1 + 0.25 x (Operating pressure) to 0.25 + 0.25 x(Operating pressure) MPa Refer to below “Graph (1)”.
A
0 10.1
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
Pilo
t pre
ssur
e (M
Pa)
Operating pressure (MPa)
Graph (1) VND� 02 D Pilot Pressure (N.O. type)
Pilot pressure should be within the range of A against the operating pressure.
Port size Flow characteristics Weight [kg]Av x 10-5
Orifice sizeø [mm]Model
VND10�D-6AVND10�D-8AVND10�D-10AVND20�D-10AVND20�D-15AVND30�D-20AVND40�D-25AVND50�D-32AVND60�D-40AVND70�D-50A
Flange Note)
1
2
1 81 4
3 8
1 23 4
0.3
0.6
0.91.42.33.65.7
7
20
15
25324050
1 411 21
262831
120130240380440920
1500
––––––––––
Valve Specifications
Flow Characteristics
How to Order Brackets
L
OptionNone
With visual verificationof operation
—
S
Series V100 - Valves - page 353Series SYJ300/500/700 - Valves - page 369Series KQ2 - Fittings - page 1184Series TU - Tubing - page 1223
Related Products
Product Recommendation
Stocked items for fast delivery
EVND104D-F8A-LEVND104DS-F8A-LEVND104D-F10AEVND104DS-F10A
EVND104DS-F10A-LEVND200D-F10A-LEVND200D-F15AEVND200D-F15A-L
EVND200DS-F15AEVND200DS-F15A-LEVND300D-F20A-LEVND300DS-F20A-L
EVND400D-F25AEVND400D-F25A-LEVND400DS-F25A-LEVND500D-F32A-L
EVND600D-F40A-LEVND700D-F50A-L
Thread typeF G Ported
Series VND – Air Operated 2 Port Valve For Steam1402
Pro
cessV
alves
Port size 10A, 15A, 20A, 25A
Port size 6A, 8A, 10A
Model
VND20�D-F10AVND20�D-F15AVND30�D-F20AVND40�D-F25A
Main port A
63
8090
B
42
5060
C
28
3540
D
14
17.520
E
73.5
85101
F
81.5
93109
G
4
56
M
52
6272
N
26
3136
P
4.5
5.56.5
Q
24.3
28.333.3
R
2.3
2.32.3
S
25
3035
T
34
4349
U
56
61.574
3 81 23 41
Model
VND10�D-F6AVND10�D-F8AVND10�D-F10A
Main port1 81 43 8
Pilot port(Reverse side P2)
(Reverse side P2)
Main port
Bracket (Option)
(Valv
e ope
n)
Indicator (Option)
2-M4 depth 7
Pilot port
Main port
G (V
alve
ope
n)
Indicator (Option)
Bracket (Option)
2- G
2- G1/8
2- G
Dimensions
Air Operated 2 Port Valve For Steam – Series VND 1403
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
Port size
Dimensions
32A, 40A, 50A
Model
VND50�D-F32AVND60�D-F40AVND70�D-F50A
Main portRc
Pilot portRc A
105120140
B
7796
113
C
536074
D
26.53037
E
121.5138161
F
202424
G
130.5148171
H
81012
J
556374
1 41 2
11
2
1 81 41 4
Pilot port
Main port
H (V
alve
ope
n)
Indicator (Option)
Series PA3000/5000 – Process Pump1404
Pro
cessP
um
p
• Compact, large capacity diaphragm type pump (PA3000:Up to 20 l/min, PA5000 up to 45 l/min).• Compatible with a wide variety of fluids.• Easy adjustament of discharge pressure and flow rate with adjustament of the pilot air pressure.• Self-priming type makes priming unnecessary.
Process PumpSeries PA3000/5000
Features
SymbolHow to Order
Product Recommendation
Specifications Automatically Operated type
Stocked items for fast delivery
PA3110-F03PA3120-F03
PA3210-F03PA3220-F03
PA3213-F03PA5110-F04
PA5120-F04PA5210-F04
PA5110-F06PA5210-F06
Related Products
Series AN - Silencer- page 556 Series PF3W - Digital Flow Swith for Water - page 1317 Series ZSE/ISE80 - Digital Pressure Switch for Fluids - page 1290Series VNB - 2 Port Air Operated Valves - page 1466Series VXZ - Pilot Operated 2 Port Solenoid Valves - page 1451Series AW - Filter Regulator - page 1088Series SY - Valves - page 65, 101, 417Series VQ - Valves - page 241Series SYJ300/500/700 - Valves - page 369Series VHS- Hand Valve - page 552Series KQ2 - Fittings - page 1184Series TU - Tubing - page 1223
0 F
35
Body size3/8 standard1/2 standard
Actuation
030406
Connection port size3/8 (10A): PA31/2 (15A): PA53/4 (20A): PA5
Diaphragm material03
Automaticaly operatedAir operated
12
Liquid contactbody material
ADC12 (aluminum)SCS14 (stainless steel)
1 1PA 3 03
* Each of the values above indicates use at ordinary temperatures with fresh water.
Model Automatically operated typePA310
1/2, 3/43/8
G 1/4
PTFE, NBRPTFE, PFA
0 to 0.6MPa
Up to 6m(liquid inside pump)
0 to 60°C (with no freezing)0 to 60°C (no freezing)
0.2 to 0.7MPa1.05MPa
Horizontal (with mounting foot at bottom)
PA320 PA510 PA520
ADC12 SCS14 SCS14ADC12
1.7kg 2.2kg 6.5kg3.5kg
Port sizeMain fluid suction/discharge port
Liquid contact areasDiaphragmCheck valve
Pilot air supply/exhaust port
Dry
Wet
Material
Suction lifting range
Discharge rateAverage discharge pressurePilot air consumption
Fluid temperatureAmbient temperatureNoise valuePilot air pressureWithstand pressureMounting positionWeight
1 to 20l/min 5 to 45l/min
Max. 92 dB(A) (80dB(A): With silencer AN20) Max. 89 dB(A) (78dB(A): With silencer AN20)
Maximum 200l/min (ANR) Up to 1m
(interior of pump dry)
Maximum 300l/min (ANR) Up to 2m
(interior of pump dry)
Thread typeF G
Symbol
12
Diaphragmmaterial
PTFENBR
Automaticallyoperated
�
�
Applicable actuation
Air operated
�
—
Automatically operated type
FLUID OUTAIR SUP
AIR EXH FLUID IN
Air operated type
FLUID OUTP1P2
FLUID IN
Process Pump – Series PA3000/5000 1405
Pro
cess
Pu
mp
For more product options and details see our specifi c catalogues or on-line information.
Materials
Flow Characteristics
ModelsLiquid contact
area
Series PA3000Series PA5000
BodyDiaphragm
Aluminium (ADC12)Fluororesin Nitrile rubberPA3110PA5110
PA3120PA5120
Stainless steel (SCS14)Fluororesin Nitrile rubber
PA3210PA5210
PA3220PA5220
Viscosity characteristics(flow rate correction for viscous fluids)
100
50
0 1 10 100 1000Viscosity [mPa.s]
Ratio
of d
ischa
rge
rate
for f
resh
wat
er [%
]
ModelAir operated type
PA3113
Rc 1/2, 3/4Rc 3/8
G 1/4
PTFEPTFE, PFA
0 to 0.4MPa
Up to 6m (liquid inside pump)
0 to 60ºC (with no freezing)0 to 60ºC (no freezing)
0.1 to 0.5MPa0.75MPa
Horizontal (with mounting foot at bottom)
1 to 7Hz (0.2 to 1Hz also possible depending on conditions Note 2))
PA3213 PA5113 PA5213
ADC12 SCS14 SCS14ADC12
1.7kg 2.2kg 6.5kg3.5kg
Port size
Main fluid suction/discharge port
Liquid contact areasDiaphragmCheck valve
Pilot air supply/exhaust port
Dry
Wet
Material
Suction lifting range Note1)
Discharge rateAverage discharge pressurePilot air consumption rate
Fluid temperatureAmbient temperaturePilot air pressureWithstand pressureMounting positionWeightRecommended operating cyclesPilot air solenoid valverecommended Cv factor Note 3)
0.1 to 12l/min 1 to 24l/min
Maximum 150l/min (ANR) Maximum 250l/min (ANR) Up to 1m
(interior of pump dry) Up to 0.5m
(interior of pump dry)
0.20 0.45
∗ Each of the values above indicates use normal temperatures with fresh water.Note 1)�With cycles at 2Hz or moreNote 2)�After initial suction of liquid operating at 1 to 7Hz, it can be used with operation at lower cycles.
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur.
Note 3)�With a low number of operating cycles, even a valve with a small Cv factor can be operated.
Specifications Air Operated Type
Series PA3000/5000 – Process Pump1406
Pro
cessP
um
p
PA30 Flow Characteristics PA50 Flow Characteristics
0.6
0.5
0.4
0.3
0.2
0.1
0
Discharge rate [l/min]
Dis
char
ge p
ress
ure
[MPa
]
SUP = 0.7 MPa
SUP = 0.5 MPa
SUP = 0.2 MPa
Air consumption 100 l/min (ANR)
Air consumption 50 l/min (ANR)
SUP = 0.7 MPa
SUP = 0.5 MPa
SUP = 0.2 MPa
Air consumption 200 l/min (ANR)
Air consumption 100 l/min (ANR)
10 20
0.6
0.5
0.4
0.3
0.2
0.1
0
Discharge rate [l/min]D
isch
arge
pre
ssur
e [M
Pa]
10 30 40 5020 60
Performance Curve: Automatically Operated Type
Performance Curve: Air Operated Type
PA313 Flow Characteristics PA513 Flow Characteristics
0
0.5
0.4
0.3
0.2
0.1
0
Dis
char
ge p
ress
ure
[MPa
]
2 4 6 8 10 12
SUP = 0.4 MPa
SUP = 0.2 MPa
SUP = 0.3 MPa
Discharge rate [l/min]
SUP = 0.5 MPaCycle 7 HzCycle 5 HzCycle 3 Hz
5 10 15 20 25
Discharge rate [l/min]
0.1
0.2
0.3
0.4
0.5
Dis
char
ge p
ress
ure
[MPa
]
SUP = 0.2 MPa
SUP = 0.3 MPa
SUP = 0.5 MPa
SUP = 0.4 MPa
Cycle 5 HzCycle 3 HzCycle 1 Hz
Performance Curve: Air Operated Type
Process Pump – Series PA3000/5000 1407
Pro
cess
Pu
mp
For more product options and details see our specifi c catalogues or on-line information.
Dimensions
PA3000
PA5000
130
3
PROCESSPUMP
FLUID I N
FLUID IN3/8
FLUID OUT3/8
9032
1054-ø7 7.5
68 85
PROCESSPUMP
165
202
167
OUT
I N
56112
114
48.5
132.
5
FLUID IN1/2, 3/4
FLUID OUT1/2, 3/4
SUP
EXH
5.5Reset button
AIR SUP(pilot air supply port)1/4
1/4
AIR EXH(pilot air exhaust port)
2
100
44.5 74
.511
5
SUP
RESET
EXH
56
3.53
58.5
103.
512
5.5
AIR SUP(pilot air supply port)
1/4
Reset button
1/4
AIR EXH(pilot air exhaust port)
179 4-ø9
90 90
Series IP8000/8100 – Electro-Pneumatic Positioner1408
Pro
cessV
alves
• Lever arm and rotary shaft versions.• 4~20mA current input.• IP65 splashproof construction.• Single or double acting• ATEX version available
Electro-Pneumatic Positioner (Lever type / Rotary type)Series IP8000/8100
Features
How to Order
Symbol AccessoriesApplicable model
—ABCDEFGHJ
JR
None (Standard)ø0.7 Output restriction with pilot valve Note 3)
ø1.0 Output restriction with pilot valve Note 3)
Fork lever-type fitting M Note 4)
Fork lever-type fitting S Note 5)
For stroke 35 to 100 mm with lever unit Note 6)
For stroke 50 to 140 mm with lever unit Note 6)
Compensation spring (A) Note 7)
With external scale plateWith opening current transmission (4 to 20 mA DC)/Positive operation Note 8)
With opening current transmission (4 to 20 mA DC))/Reverse operation Note 8)
IP8000���——���———
IP8100�����——����
0Type
Construction Note 1)
000IP8 0 X14
000IP8 3
3
0
0
Pressure gaugeSymbol
0123
0No terminal box
Lever typeIP8000
Rotary typeIP8100
Option ATEX directive compliance and connection
X14
ATEX directive category 2Intrinsically safe explosion-proof itemAir connection port: 1/4 NPTConduit connection port: M20 x 1.5With blue cable gland
—LW
Option
—Low temperature (–40 to 60°C)With internal opening indicator plate
Applicable modelIP8000-X14
��—
IP8100-X14���
Symbol
ATEX Directive IntrinsicallySafe Explosion proof
Standard
1With terminal box
(ExdIIBT5) TIIS (Japan)explosion-proof item
Connection
—MN
Air Electric
Rc1/4Rc1/4Rc1/4
G1/2M20 x 1.51/2NPT
Applicable modelIP800-00
���
IP800-01�——
SymbolPressure
None0.2 MPa0.3 MPa1.0 MPa
Note 1) For construction No.1(with terminal box), the ambient and fluid temperatures are as follows: • ExdIIBT5: –20 to 60°C• Non-explosion proof (non hazardous Iocations only): –20 to 80°CThe positioner body is EXdIIBT5 labeled.
Note 2) If two or more accessories are required, the part numbers should be made according to alphabetical order. (ex. IP8100-011-AG)
Note 3) “A” is applied to approx 90cm3-capacity actuator.“B” is applied to approx 180cm3-capacity actuator.
Note 4) Fork lever-type fitting MX (Connection thread: M6 x 1) for IP8100-00--X14.Note 5) Fork lever-type fitting SX (Connection thread: M6 x 1) for IP8100-00--X14.Note 6) Standard lever is not attached.Note 7) It is to be used together with “A” or “B” when tending to overshoot by the use
of “A” or “B”. It is mounted to the body as a replacement of the standard compensation
spring.Note 8) Symbol J/JR is with terminal box, non-explosion proof specification. Select 1
for Construction. Positive operation signifies clockwise rotational direction by the main actuator shaft when positioner cover is viewed from the front.
Accessories Note 2)
000100
Electro-pneumatic lever typeElectro-pneumatic rotary type
MPa
MPa
OUT2
ELECTORO PNEUMATIC IP8000
P O S I T I O N E R
MPa
MPa
OUT2
ELECTORO PNEUMATIC IP8000
P O S I T I O N E R
Product Recommendation
Stocked items for fast delivery
IP8000-030-Q IP8100-000-H-Q
Related Products
Series G - Pressure Gauge - www.smc.euSeries AF - Air Filter- page 1082 Series AW - Filter Regulator - page 1088Series IR - Precision Regulator - page 1095Series KQ2 - Fittings - page 1184Series TU - Tubing - page 1223
Electro-Pneumatic Positioner – Series IP8000/8100 1409
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
Specifications Note 1)
FeaturesOptional Specifications
ATEX intrinsically safe explosion-proofparameter (current circuit)Exterior covering enclosureTransmission method Note 6)
Air connection portElectrical connection port Note 7)
Material/coatingWeight
Explosion proof construction Note 6)
Ambient and fluid temperature
Air consumption Note 5)
Electro-Pneumatic Positioner
———
235 ±15Ω (4 to 20 mA DC)
Within 0.1% F.S./CWithin 0.3% F.S./0.01 MPa
TIIS explosion-proof construction (ExdIIBT5)ATEX intrinsically safe explosion-proof construction (II2G Ex ibIICT5/T6)
Ui ≤ 28 V, Ii ≤ 125 mA, Pi ≤ 1.2 W, Ci ≤ 0 nF, Li ≤ 0 mH
—
2.4 kg (Without terminal box)/2.6 kg (With terminal box)
5 l/min (ANR) or less (SUP = 0.14 MPa)11 l/min (ANR) or less (SUP = 0.4 MPa)
Type
Item
IP8000
4 to 20 mA DC (Standard) Note 2)
Within ±0.5% F.S.
80 l/min (ANR) or more (SUP = 0.14 MPa) 200 l/min (ANR) or more (SUP = 0.4 MPa)
General structure: –20 to 80°C
JISF8007, IP65 (conforms to IEC Pub.60529)
Rc 1/4 female thread, NPT 1/4 female threadG 1/2 female thread, M20 x 1.5 female thread, NPT 1/2 female thread
Aluminum diecast body/baking finish with denatured epoxy resin
IP8100
Lever type lever feedback
10 to 85 mm (Allowable deflection angle 10 to 30º)
Single action
Within 0.1% F.S.Within ±1% F.S.
Within 0.75% F.S.
Double action Single action Double actionRotary type cam feedback
60 to 100º Note 3)
Within 0.5% F.S.Within ±2% F.S.Within 1% F.S.
Input currentMin. operating currentIntra-terminal voltageMax. supplied powerInput resistanceSupply air pressureStandard strokeSensitivity Note 4)
Linearity Note 4)
Hysteresis Note 4)
Repeatability Note 4)
Coefficient of temperatureSupply pressure fluctuationOutput flow Note 5)
TIIS explosion-proof: –20 to 60°CATEX intrinsically safe explosion-proof: –20 to 80°C (T5) –20 to 60°C (T6)–40 to 60°C (T6)/-L type low-temperature specification
Note 1) Specification values are given at normal temperature (20°C).Note 2) 1/2 Split range (Standard)Note 3) Stroke adjustment: 0 to 60°, 0 to 100°Note 4) Characteristics relating to accuracy differ depending on combination with other constituent
loop equipment, such as positioners and actuators.Note 5) (ANR) indicates JIS B0120 standard air.Note 6) Model selection required for explosion proof construction and HART transmission.Note 7) Thread type can be specified by model selection.
Anal
ogue
out
put Wiring
Output signalPower supply voltageLoad resistanceAccuracyHysteresis
Alar
m o
utpu
t 1, 2
WiringApplicable standardsPower supply voltageLoad resistanceAlarm ONAlarm OFF (Leakage current)Response time
Electro-Pneumatic Positioner
12 to 35 V DC(Power supply voltage –12 V) 20 mA DC or less
±2% F.S. or less Note 1)
Within 1% F.S. ———————
TypeItem
IP8100-01-J/JR (Non-explosion proof)
Note 1) Indicates analogue output accuracy with respect to actuator angle.
2-line4 to 20 mA DC
0.14 to 0.7 MPa
Series IP8000/8100 – Electro-Pneumatic Positioner1410
Pro
cessV
alves
Accessories / Option
Side mounting with the fork lever assembly M
Rear mounting with the fork leverassembly S
Actuator main shaft
Actuator main shaft
166.1
N
M 5
L1=1
01(S
ty
pe: 7
7)
63
(S
type
: 39)
39(M
ty
pe: 6
3)
L2=3
1(M
ty
pe: 5
5)
Cable connector G1/2
Pilot valve with output restriction (IP8000 / 8100)
ActuatorCapacity90 cm3
180 cm3
Orifice size Part number P36801080P36801081
Pilot unitpart numberP565010-18P565010-19
In general, mounting on a small-size actuator may cause hunting. For prevention, a pilot valve with a built-in output restriction is available. The restriction is removable.
External feedback lever (IP8000)
Resin connector (Non-explosion proof specification)
Part nameResin-made cable clamp unit (A)Resin-made cable clamp unit (B)
Part numberP368010-26P368010-27
Suited cable outer diameter
ø7 to ø9ø9 to ø11
Stroke
10 to 85 mm35 to 100 mm50 to 140 mm6 to 12 mm
IP8000P368010-20P368010-21P368010-22P368010-260
Unit number Size N
15019527575
Size M
12511011075
ø0.7ø1
Different feedback levers are available dependent upon valve strokes. Order according to the valve stroke.
Model selectionaccessory
AB
O-ring P5Restrictor
Orifice size
OUT2 OUT1
Restrictor mounting diagram Pilot valve bottom view
Note) Output orifice not required for Smart Positioner regardless of actuator capacity.
Fork lever-type fittings (IP8100)
2 types of rotary type IP8100 fork lever-type fittings, that differ by installation dimensions dependent on bracket installation method, and 2 types of installation portion thread sizes, are available.When installing on the side surface, using fork lever assembly M provides interchangeability with the installation dimensions of SMC IP610 positioner. When installing on the rear surface, using fork lever assembly S also provides interchangeability with the installation dimensions of SMC IP610 positioner.
Part name
Fork lever assembly MFork lever assembly SFork lever assembly MXFork lever assembly SX
Unit number
P368010-24P368010-25P368010-36P368010-37
M8 x 1.25
M6 x 1
Model selectionaccessory
CD
C Note)
D Note)
Note) Installation portion thread size is M6 x 1 for IP8100-00-X14 when accessory C or D are selected.
M8 x 1.25or M6 x 1
M8 x 1.25or M6 x 1
Model selectionaccessory
EF
Available asspecial order
Optional cable connectors are available for different cable sizes. These are not for explosion proof applications. Recommended for use in indoor applications.
Feedback lever types
Installationportion
thread size
Standardaccessory
Electro-Pneumatic Positioner – Series IP8000/8100 1411
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
Dimensions
IP8000-00 (Without terminal box)
IP8000-01 (With terminal box)
1984323.5
939
117
147
�194125
20
150
1255
4250
46302
14
100
35
166.1
3911
38
With optional resin cable clampApplicable cable O. D. ø7 to 9:P368010-26Applicable cable O. D. ø9 to 11:P368010-27
At accessory “E”: 110At accessory “F”: 110
At accessory “E”: 195At accessory “F”: 275
2 x M8 x 1.25 depth12(Female thread for side mounting)
1E
OUT2
122
23.558110192
4035
22.5
65
4 x M8 x 1.25 depth12(Female thread for rear mounting)
A
60 30214
100E
Electric conduit 2 x G1/2
42
162
117
218
939
4323.5
12512 168
20
5
50
166.1
OUT2
122
58
192
23.511040
35
65
22.5
A
4 x M8 x 1.25 depth12(Female thread for rear mounting)
2 x M8 x 1.25 depth12(Female thread for side mounting)
150
125At accessory “E”: 110At accessory “F”: 110
At accessory “E”: 195At accessory “F”: 275
A
IP8000 (Lever type)
110
38
OUT2.1/4 (Rc)With plug
OUT1.1/4 (Rc)
1/2 (G, NPT), M20Electric conduit
110
38
OUT2.1/4 (Rc)With plug
8
3911
38
A
OUT1.1/4 (Rc)
SUP.1/4 (Rc)
SUP1.1/4 (Rc)
Series IP8000/8100 – Electro-Pneumatic Positioner1412
Pro
cessV
alves
IP8100-00 (Without terminal box)
25%
100%
75%
DA 50%
0%
231198
147 11
7
�194
939
4323.5
125At accessory “H”: (with external scale plate)
OUT2
122
4250
20
58
192
23.511040
35
65
22.5
2 x M8 x 1.25 depth12Female for side mounting
4 x M8 x 1.25 depth12Female for rear mounting
A
With optional resin cable clampApplicable cable O. D. ø7 to 9:P368010-26Applicable cable O. D. ø9 to 11:P368010-27
IP8100 (Rotary type)
35
3911
38
1E
A
OUT1.1/4 (Rc)SUP.1/4 (Rc)
1/2 (G, NPT), M20Electric conduit
38
110OUT2.1/4 (Rc)46
15
100
44
24
2163 (3
9)7
70 (4
6) B-B
B B Holding spring
M8 x 12.5 or M6 x 1Actuator main shaft
Fork pin unit
Fork lever joint
Positioner body
Mounting with the fork lever joint (Option)Dimensions inside ( ) are for fork lever joint S.
IP8100-01 (With terminal box)
25%
100%
75%
DA 50%
0%
251218
162
117
939
4323.5
12512 168
At accessory “H”: (with external scale plate)
46
15
60
100
44
2 x G1/2Electric conduit
E
OUT2
122
5042
20
58
192
23.511040
35
65
22.5
2 x M8 x 1.25 depth12Female thread for side mounting
4 x M8 x 1.25 depth12Female thread for rear mounting
A
8
3911
38
A
OUT1.1/4 (Rc)
SUP.1/4 (Rc)
38
110OUT2.1/4 (Rc)
Dimensions
Smart Positioner – Series IP8001/8101 1413
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
• Easy remote parameter change and monitoring by the insertion of a built-in microcomputer and sensor.• Easy zero and span adjustments thanks to an integrated auto-calibration function. Calibration by just clicking a button.• Monitor output and software alarm for remote sensing.• HART communication, enabling remote information exchange and switching signal from the mechanical to the smart positioner.• ATEX compliant.
Smart Positioner (Lever type / Rotary type)Series IP8001/8101
Features
How to Order
ATEX Directive IntrinsicallySafe Explosion proof
Standard
Lever typeIP8001
Rotary typeIP8101
0 3 0
001IP852 0 3 4
001IP8
ATEX directive complianceATEX directive category 1
Intrinsically safe explosion-proof item52
Specifications
4 Intrinsically safe explosion proof (ATEX) +output function + HART transmission function
ElectricSymbol AirConnection
—MN
Rc1/4Rc1/4Rc1/4
G1/2M20 x 1.51/2NPT
Note) When the symbol is M for 52- ATEX directive items, a blue cable gland is included with the electrical connection.
Note)
ATEX temperature
—T6
SymbolApplicable model
IP8101IP8001T4
T5/T6
ATEXtemperature
Accessories Note 1)
Symbol AccessoriesApplicable model
—CDEFHW
None (Standard)Fork lever-type fitting MFork lever-type fitting SFor stroke 35 to 100 mm with lever unit Note 2)
For stroke 50 to 140 mm with lever unit Note 2)
With external scale plateBody with LCD window
IP8001
——
—
IP8101
——
TypeSmart lever typeSmart rotary type
001101
123
0.2 MPa0.3 MPa1.0 MPa
——
Pressure gauge
Specifications023
Basic typeWith output function {Analogue (4 to 20 mA DC) output + Alarm output x 2}With HART transmission function
Note 1) If two or more accessories are required, the part numbers should be given in alphabetical order. (ex. IP8101-010-CH)
Note 2) Standard lever is not attached.
Symbol Pressuregauge
Applicable modelIP8001 IP8101
Product Recommendation
Stocked items for fast delivery
IP8101-030-QIP8001-030-Q
IP8101-032-QIP8001-032-Q
IP8101-033-QIP8001-033-Q
Related Products
Series G - Pressure Gauge - www.smc.euSeries AF - Air Filter- page 1082 Series AW - Filter Regulator - page 1088Series IR - Precision Regulator - page 1095Series KQ2 - Fittings - page 1184Series TU - Tubing - page 1223
Series IP8001/8101 – Smart Positioner1414
Pro
cessV
alves
Specifications Note 1)
Optional Specifications
ATEX intrinsically safe explosion-proofparameter (current circuit)Exterior covering enclosureTransmission method Note 7)
Air connection portElectrical connection port Note 8)
Material/coatingWeight
Explosion proof construction Note 7)
Ambient and fluid temperature
Air consumption Note 6)
ATEX intrinsically safe explosion-proof construction(II1G Ex iaIICT4/T5/T6)
Ui ≤ 28 V, Ii ≤ 100 mA, Pi ≤ 0.7 W, Ci ≤ 12.5 nF, Li ≤ 1.5 mH
HART transmission
2.6 kg
Type
Item
General structure: –20 to 80°C
JISF8007, IP65 (conforms to IEC Pub.60529)
Rc 1/4 female threadG 1/2 female thread, M20 x 1.5 female thread, NPT 1/2 female thread
Aluminum diecast body/baking finish with denatured epoxy resin
Input currentMin. operating currentIntra-terminal voltageMax. supplied powerInput resistanceSupply air pressureStandard strokeSensitivity Note 4)
Linearity Note 4)
Hysteresis Note 4)
Repeatability Note 4)
Coefficient of temperatureSupply pressure fluctuationOutput flow Note 6)
Note 1) Specification values are given at normal temperature (20°C).Note 2) 1/2 Split range (Standard)Note 3) Stroke adjustment: 0 to 60°, 0 to 100°Note 4) Characteristics relating to accuracy differ depending on combination with other constituent loop equipment, such as
positioners and actuators.Note 5) While there is no output changes due to pressure fluctuations, when the pressure supply setting is changed following
calibration, once again adjust balance current and perform calibration. Note 6) (ANR) indicates JIS B0120 standard air.Note 7) Model selection required for explosion proof construction and HART transmission.Note 8) Thread type can be specified by model selection.
Anal
ogue
out
put Wiring
Output signalPower supply voltageLoad resistanceAccuracyHysteresis
Alar
m o
utpu
t 1, 2
WiringApplicable standardsPower supply voltageLoad resistanceAlarm ONAlarm OFF (Leakage current)Response time
TypeItem
Note 1) Indicates analogue output accuracy with respect to LCD display position value (P value).
Smart Positioner
Single action / Double action
3.85 mA DC or more12 V DC (equivalent to 600 input resistance, at 20 mA DC)
1 W (Imax: 100 mA DC, Vmax: 28 V DC)—
Within 0.2% F.S.Within ±1% F.S.Within 0.5% F.S.
Within 0.05% F.S./C— Note 5)
IP8001 IP8101
Lever type
0.14 to 0.7 MPa10 to 85 mm (Allowable deflection angle 10 to 30º)
Rotary type
0.3 to 0.7 MPa60 to 100º Note 3)
ATEX intrinsically safe explosion-proof –20 to 80°C (T4/T5) –20 to 60°C (T6)
2 l/min (ANR) or less (SUP = 0.14 MPa)4 l/min (ANR) or less (SUP = 0.4 MPa)
11 l/min (ANR) or less(SUP = 0.4 MPa)
4 to 20 mA DC (Standard) Note 2)
Within ±0.5% F.S.
80 l/min (ANR) or more (SUP = 0.14 MPa) 200 l/min (ANR) or more (SUP = 0.4 MPa)
2-line4 to 20 mA DC
Smart Positioner
10 to 28 V DC0 to 750
±0.5% F.S. or less Note 1)
—2-line
50 msec or less
—10 to 28 V DC
10 to 40 mA DCR = 350Ω ±10%
0.5 mA DC or less
DIN19234/NAMUR Standard5 to 28 V DC
(Constant current output) ≥2.1 mA DC ≤1.2 mA DC
IP801-02 52-IP801-04
Smart Positioner – Series IP8001/8101 1415
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
Accessories / Option
Side mounting with the fork lever assembly M
Rear mounting with the fork leverassembly S
Actuator main shaft
Actuator main shaft
166.1
N
M 5
L1=1
01(S
ty
pe: 7
7)
63
(S
type
: 39)
39(M
ty
pe: 6
3)
L2=3
1(M
ty
pe: 5
5)
Cable connector G1/2
External feedback lever (IP8001)
Resin connector (Non-explosion proof specification)
Part nameResin-made cable clamp unit (A)Resin-made cable clamp unit (B)
Part numberP368010-26P368010-27
Suited cable outer diameter
ø7 to ø9ø9 to ø11
Stroke
10 to 85 mm35 to 100 mm50 to 140 mm6 to 12 mm
Unit numberIP8001
P565010-323P565010-324P565010-325P565010-329
Size N
15019527575
Size M
12511011075
Different feedback levers are available dependent upon valve strokes. Order according to the valve stroke.
Fork lever-type fittings (IP8101)
2 types of rotary type IP8101 fork lever-type fittings, that differ by installation dimensions dependent on bracket installation method, and 2 types of installation portion thread sizes, are available.When installing on the side surface, using fork lever assembly M provides interchangeability with the installation dimensions of SMC IP610 positioner. When installing on the rear surface, using fork lever assembly S also provides interchangeability with the installation dimensions of SMC IP610 positioner.
Part name
Fork lever assembly MFork lever assembly SFork lever assembly MXFork lever assembly SX
Unit number
P368010-24P368010-25P368010-36P368010-37
M8 x 1.25
M6 x 1
Model selectionaccessory
CD
C Note)
D Note)
Note) Installation portion thread size is M6 x 1 for IP8100-00-X14 when accessory C or D are selected.
M8 x 1.25or M6 x 1
M8 x 1.25or M6 x 1
Model selectionaccessory
EF
Available asspecial order
Optional cable connectors are available for different cable sizes. These are not for explosion proof applications. Recommended for use in indoor applications.
Feedback lever types
Installationportion
thread size
Standardaccessory
Series IP8001/8101 – Smart Positioner1416
Pro
cessV
alves
Dimensions
IP8001 (Lever type)
Note) The accessory body cover for LCD with viewing panel can be selected irrespective of specifications.
38
110
OUT2.1/4 (Rc, NPT)With plug
122
5020
42
58
192
23.511040
35
65
22.5
A
4 x M8 x 1.25 depth12Female for rear mounting
2 x M8 x 1.25 depth12Female thread for side mounting
0003
-IP8001- -W0204
IP8001- -W
109
14
2328
3911
38
2 x 1/2 (G, NPT), M20Electric conduit
OUT1.1/4 (Rc, NPT)
SUP.1/4 (Rc, NPT)
A
213
31
4612
1
E
With optional resin cable clampApplicable cable O. D. ø7 to 9:P368010-26Applicable cable O. D. ø9.1 to 11:P368010-27
Applicable cable O. D. ø6 to 12(Only supplied when the M20 is selected forintrinsically safe explosion proof products)
Resin cable gland
5
166.1
�229
198
147
939
4323.5
125150
125
OUT2
At accessory “E”: 110At accessory “F”: 110
At accessory “E”: 195At accessory “F”: 275
38
110
OUT2.1/4 (Rc, NPT)With plug
122
5020
42
58
192
23.511040
35
65
22.5
A
4 x M8 x 1.25 depth12Female for rear mounting
2 x M8 x 1.25 depth12Female thread for side mounting
109
14
2328
3911
38
1/2 (G, NPT), M20Electric conduit
OUT1.1/4 (Rc, NPT)
SUP.1/4 (Rc, NPT)
A
213
31
4612
1
E
5
166.1
�229
198
147
939
4323.5
125150
125
OUT2
At accessory “E”: 110At accessory “F”: 110
At accessory “E”: 195At accessory “F”: 275
Smart Positioner – Series IP8001/8101 1417
Pro
cess
Val
ves
For more product options and details see our specifi c catalogues or on-line information.
IP8101 (Rotary type)0003IP8101- -W
0204-IP8101-
Note) The accessory body cover for LCD with viewing panel can be selected irrespective of specifications.
46
15
121
44
38
110OUT2.1/4 (Rc, NPT)
Holding spring
Mounting with the fork lever joint (Option)Dimensions inside ( ) are for fork lever joint S.
M8 x 12.5 or M6 x 1Actuator main shaft
Fork pin unitFork lever joint
Positioner body
24
2163 (3
9)7
70 (4
6) B-B
B B
OUT2.1/4 (Rc, NPT) 110
38
44
121
15
46
35
3911
38SUP.1/4 (Rc, NPT)OUT1.1/4 (Rc, NPT)
1E
A
1/2 (G, NPT), M20Electric conduit
OUT2
At accessory “H”: (with external scale plate)
MPa
MPa
SMC
SMC
0%
50%
DA75
%
100%
25%
125
23.5 4339
9
147
198231
�194
117
With optional resin cable clampApplicable cable O. D. ø7 to 9:P368010-26Applicable cable O. D. ø9.1 to 11:P368010-27
122
5020
42
58
192
23.511040
35
65
22.5
A
4 x M8 x 1.25 depth12Female for rear mounting2 x M8 x 1.25 depth12
Female for side mounting
A
SUP.1/4 (Rc, NPT)OUT1.1/4 (Rc, NPT)
38
1139
2823
1410
9
2 x 1/2 (G, NPT), M20Electric conduit
Applicable cable O. D. ø6 to 12(Only supplied when the M20 is selected forintrinsically safe explosion proof products)
Resin cable gland
OUT2
MPa
MPa
SMC
SMC
0%
50%
DA75
%
100%
25%
125
23.5 43
399
147
198231
�229
At accessory “H”:(with external scale plate)
A
22.5
65
3540 110
23.5
192
58
4220
50122
4 x M8 x 1.25 depth12Female thread for rear mounting2 x M8 x 1.25 depth12
Female thread for side mounting