8
Homeline ® Load Centers and Circuit Breakers Features that outclass the competition

Features that outclass the competition€¦ · manual adjustment to speed final installation. Covers are included with the load center for purchasing convenience, and individually

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Features that outclass the competition€¦ · manual adjustment to speed final installation. Covers are included with the load center for purchasing convenience, and individually

Homeline® Load Centersand Circuit BreakersFeatures that outclassthe competition

Homeline Brochure 2006 3/6/06 2:59 PM Page 1

Page 2: Features that outclass the competition€¦ · manual adjustment to speed final installation. Covers are included with the load center for purchasing convenience, and individually

2

1

2 2 2

34

5

6 6

7

8

9

9

10

11

9

The quality you expect from

Square D®, the industry leader,

is built into all Homeline® Load

Centers. One example is our

exclusive Qwik-Open® Circuit

Breakers, which have given

homeowners a new standard

for reliable, fast-acting circuit

protection. In addition, our

commitment to technological

leadership has brought a new

level of electrical safety to the

residential market, with innovative

solutions such as Surgebreaker®

Plus Whole House Surge Protection

and Arc-D-tect® Arc Fault Circuit

Interrupters. From leading

innovations in circuit protection

and exclusive features to a

comprehensive selection of options

and accessories, Homeline Load

Centers are the smart choice for

value-minded contractors,

remodelers, builders and

homeowners. Feature for feature,

Homeline panels outclass the

competition.

Homeline Brochure 2006 3/6/06 2:59 PM Page 2

Page 3: Features that outclass the competition€¦ · manual adjustment to speed final installation. Covers are included with the load center for purchasing convenience, and individually

3

Combinationflush/surface covers

Homeline indoorcovers for 8 circuitand larger panels arecombination flush/surface to meet allmounting situations.

Floating, spring-mounted trim providesautomatic flush adjust-ment to ensure properbreaker and trimalignment withoutmanual adjustment to speed final installation.

Covers are included with the load center forpurchasing convenience, and individuallypackaged to reduce the chance of shippingdamage, making them easier to storebetween rough-in and trim-out. Covers nowinclude provisions for a door lock, and thetrim has the top two branch circuit twistoutsremoved to make it easier to removeremaining twistouts.

Complete line of accessories

A complete line of Homeline Load Centeraccessories maximizes application flexibility.From ground bar kits to bolt-on rainproofhubs, filler plates, door locks, and more,Homeline Load Centers satisfy almost anyinstallation requirement.

Rainproof enclosures

Homeline Load Centers are available in afull line of NEMA Type 3R rainproof enclo-sures, with Square D type rain-tight bolted(RB) hub for fast and convenient top-feedconduit connection. Side-opening devicesfeature a stainless steel door latch and centermounting on back.

1. Panels areavailable as eithermain breaker or main lugs.

2. Straight-in wiringmains designhelps reduce theneed to bendservice cable,cutting waste andsaving installationtime.

3. Convertible mains let you meet changing job site require-ments fast by field converting between main breaker and main lugs. Formaximumflexibility our“universal mains”panels areprovided withoutmains, allowingyou to add afield-installedmain circuitbreaker or mainlugs kit to meeteither application.

4. Standard 22,000/10,000ampere shortcircuit currentrating on mainbreaker – providesincreased highfault currentprotection whenneeded, withoutchanging theentire panel.

5. Panel interiors areeasily removedfor paint or theftprotection. Single,captive screwcan’t be lost;interior mountsquickly and easily(indoor only).

6. Split branch neutral, with upto 50% more terminations than required,reduces clutterand simplifieswiring.

7. Combinationslot/square-driveneutral, groundand cover screwslet you use eithera standard flat-blade screwdriveror a square-head driver for reducedslippage andimproved torque.

8. Bus and interiorassembly isamong the mostrugged in theindustry.

9. Three ground bar mountinglocations (left,right and bottom)let you pick theeasiest spot towire.

Homeline Load Center Features

10. Tangential main serviceknockoutseliminate the need for costlyservice conduitoffset, simplify-ing and speeding installation.

11. Complete loadcenter rotates fortop or bottomfeed to meet jobsite requirementsand reduceservice cablewaste.

12. Automatic flushadjustment cover(below) speedsinstallation,especially onuneven wallsurfaces.

12

Homeline Brochure 2006 3/6/06 2:59 PM Page 3

Page 4: Features that outclass the competition€¦ · manual adjustment to speed final installation. Covers are included with the load center for purchasing convenience, and individually

4

Homeline®

Arc-D-tect® ArcFault CircuitInterrupter

The advancedtechnology of theexclusive Square DArc-D-tect AFCIprovides the highestlevel of circuitprotection availabletoday. These circuitinterrupters arespecifically designedto detect dangerouslow-level arc faultsand providetraditional overloadand short circuitprotection as well.This single-polebreaker installs aseasily as our GFCIbreaker and offers thesame high level ofreliability.

No other name in

circuit protection is more

trusted for reliability and

performance than Square D®.

Our products have

revolutionized the industry

and continue to make the

residential use of electricity

safe and convenient for

millions of people every day.

Homeline Brochure 2006 3/6/06 3:00 PM Page 4

Page 5: Features that outclass the competition€¦ · manual adjustment to speed final installation. Covers are included with the load center for purchasing convenience, and individually

Ground Fault Protection

Square D introducedthe first ground faultcircuit interrupter(GFCI) in 1967. Itwas such a good idea,electrical codes nowrequire ground faultprotection for bath-rooms, pools, spas andother applications.We’ve continued thatleadership, expandingour offering throughtwo-pole 60A circuitbreakers for whirl-pool and hot tubapplications.

Surgebreaker Secondary Surge Arrester

The Surgebreakersecondary surgearrester plugs on like a circuit breaker tohelp protect thehome’s electrical

Unsurpassed Qwik-Open®

Protection

Homeline CircuitBreakers provide thehigh level of protec-tion you expect fromSquare D. Single pole15A and 20A Qwik-Open breakers tripwithin 1/60th of asecond – faster thanthe blink of an eye.When it comes toelectrical protection,fast response iscritical.

system and hardwiredappliances fromsurges up to 20,000volts. Downstreampoint-of-use surgesuppressors normallyonly handle surges upto 6,000 volts, andonly protect the products pluggeddirectly into them.For complete protec-tion of sensitive electronics like com-puters, you need bothlevels of protection.

Surgebreaker PlusMulti-path SurgeArrester

The latest innovationin surge protectionfrom Square D, theSurgebreaker Plus,provides whole houseprotection for up tofour telephone lines,two coax cable linesand is hard-wired toprotect the entirepanel and homewiring.

Homeline Circuit Breaker andSurgebreaker® Features

5

USE CIRCUIT BREAKERS PROPERLY

Electrical protection requires that

circuit breakers be used properly.

Only breakers marked on the load

center label or wiring diagram

should be used to maintain the

integrity and safety intended.

That’s why Homeline Load Centers

are marked to accept only genuine

Homeline Circuit Breakers.

Homeline Circuit Breakers should

only be used in equipment marked to

accept them. Any other use may void

your warranty, reduce protection,

increase liability risks and violate

the National Electrical Code.

Homeline Brochure 2006 3/6/06 3:00 PM Page 5

Page 6: Features that outclass the competition€¦ · manual adjustment to speed final installation. Covers are included with the load center for purchasing convenience, and individually

6

Homeline® Load Centers, Circuit Breakers and Surgebreaker® Products

Max Load Center &Mains Branch Branch Cover Catalog Number GroundRating Spaces Circuits F = Flush, S = Surface Bar

Fixed Main Lugs

70 2 4 HOM24L70 (F/S) PK3GTA1100 6 12 HOM612L100 (F/S) PK7GTA125 4 8 HOM48L125GC Included

Convertible Main Lugs

8 16 HOM816L125C PK15GTA8 16 HOM816L125TC Included12 12 HOM12L125C PK15GTA

125 12 24 HOM1224L125TC Included16 24 HOM1624L125C PK15GTA20 20 HOM20L125C20 24 HOM2024L125TC Included24 24 HOM24L125TC

150 30 30 HOM30L150C PK23GTA16 32 HOM1632L200TC16 32 HOM1632L200TCFT Included

200 20 40 HOM2040L200TC30 30 HOM30L200C PK23GTA30 40 HOM3040L200TC Included40 40 HOM40L200C PK23GTA

225 42 42 HOM42L225C PK23GTA

SINGLE PHASE LOAD CENTERS – INDOOR MAIN LUGS

Max Load Center &Mains Branch Branch Cover Catalog Number GroundRating Spaces Circuits F = Flush, S = Surface Bar

Convertible Main Breaker

8 16 HOM816M100C PK15GTA8 16 HOM816M100TC Included12 12 HOM12M100C PK15GTA

100 12 24 HOM1224M100TC Included 20 20 HOM20M100C PK15GTA24 24 HOM24M100C30 30 HOM30M100C PK23GTA12 24 HOM1224M125C PK15GTA

125 12 24 HOM1224M125TC Included24 24 HOM24M125C PK15GTA30 30 HOM30M125C PK23GTA16 32 HOM1632M150TC Included

150 20 30 HOM2030M150TC30 30 HOM30M150C PK23GTA12 24 HOM1224M200TC Included16 32 HOM1632M200TC20 40 HOM2040M200C PK23GTA

200 20 40 HOM2040M200TC Included30 30 HOM30M200C PK23GTA30 40 HOM3040M200TC Included40 40 HOM40M200C42 42 HOM42M200C PK23GTA

225 42 42 HOM42M225C PK23GTAUniversal Mains – No Main Circuit Breaker or Main Lugs

16 32 HOM1632U200TC200 20 40 HOM2040U200TC Included

30 40 HOM3040U200TC

SINGLE PHASE LOAD CENTERS – INDOOR MAIN BREAKER

MaxMains Branch Branch Load Center Ground Rating Spaces Circuits Catalog Number Bar

Fixed Main Lugs

70 2 4 HOM24L70RB PK4GTA100 6 12 HOM612L100RB PK7GTA125 4 8 HOM48L125GRB Included

Convertible Main Lugs

8 16 HOM816L125RB12 12 HOM12L125RB PK15GTA125 12 24 HOM1224L125RB20 20 HOM20L125RB12 12 HOM12L200RB20 40 HOM2040L200RB

200 30 30 HOM30L200RB PK23GTA

40 40 HOM40L200RBConvertible Main Breaker

8 16 HOM816M100RB PK15GTA100 12 12 HOM12M100RB PK12GTA

20 20 HOM20M100RB125 24 24 HOM24M125RB PK15GTA

150 30 30 HOM30M150RB20 40 HOM2040M200RB

200 30 30 HOM30M200RB PK23GTA30 40 HOM3040M200RB40 40 HOM40M200RB

225 16 24 HOM1624M225RBFeed Thru Lugs

150 8 16 HOM816M150FTRB PK15GTA-L200 8 16 HOM816M200FTRB

Universal Mains

200 8 16 HOM816U200FTRB PK15GTA-L

SINGLE PHASE LOAD CENTERS – OUTDOOR

Homeline Brochure 2006 3/6/06 3:00 PM Page 6

Page 7: Features that outclass the competition€¦ · manual adjustment to speed final installation. Covers are included with the load center for purchasing convenience, and individually

7

aker® Products

BRANCH CIRCUIT BREAKERS 10,000 AIR GROUND FAULT CIRCUIT INTERRUPTERS 10,000 AIR

SURGEBREAKER® PLUS WHOLE HOUSE SURGE PROTECTOR

Type Catalog Number

Indoor SDSB1175C

ARC FAULT CIRCUIT INTERRUPTERS 10,000 AIRAmpere Rating One Pole

15 HOM115AFI20 HOM120AFI

TANDEM CIRCUIT BREAKERSAmpere Rating One Pole

15 & 15 HOMT151515 & 20 HOMT152020 & 20 HOMT202030 & 15 HOMT301530 & 20 HOMT3020

QUAD TANDEM CIRCUIT BREAKERS

Ampere Rating One Pole Two Pole Common Trip

15 HOM115 HOM21520 HOM120 HOM22025 HOM125 HOM22530 HOM130 HOM23035 HOM23540 HOM140 HOM24045 HOM24550 HOM150 HOM25060 HOM26070 HOM27080 HOM28090 HOM290100 HOM2100110 HOM2110125 HOM2125150 HOM2150BB175 HOM2175BB200 HOM2200BB

Ampere Rating One Pole Two Pole

15 HOM115GFI HOM215GFI20 HOM120GFI HOM220GFI30 HOM230GFI40 HOM240GFI50 HOM250GFI

MAIN CIRCUIT BREAKER KITSUse With

Main Convertible Load 22,000 AIR Lug Wire Size Circuit Breaker Center Main Circuit AWG/kcmil

Rating (A) Mains Rating Breaker Al or CuQOM1 Frame Size

50 100–125 QOM50VH60 100–125 QOM60VH70 100–125 QOM70VH80 100–125 QOM80VH #12–2/090 100–125 QOM90VH100 100–125 QOM100VH 110 125 QOM110VH 125 125 QOM125VH

QOM2 Frame Size

100 150–225 QOM2100VH 125 150–225 QOM2125VH 150 150–225 QOM2150VH #4–300 175 200–225 QOM2175VH 200 200–225 QOM2200VH225 225 QOM2225VH

Ampere RatingCatalog NumberOne Pole Two Pole

(2) 15 15 HOMT1515215(2) 15 20 HOMT1515220(2) 15 25 HOMT1515225(2) 15 30 HOMT1515230(2) 15 40 HOMT1515240(2) 15 50 HOMT1515250(2) 20 20 HOMT2020220(2) 20 25 HOMT2020225(2) 20 30 HOMT2020230(2) 20 40 HOMT2020240(2) 20 50 HOMT2020250

Homeline Brochure 2006 3/6/06 3:00 PM Page 7

Page 8: Features that outclass the competition€¦ · manual adjustment to speed final installation. Covers are included with the load center for purchasing convenience, and individually

National Electrical Code is a registeredtrademark of the National Fire Protection Association.

Light Duty Enclosed Switch

The Square D light duty enclosed switchis ideal for home applications in disconnectingpower to a workshop, hobby room, furnace or garage.

Air Conditioning Disconnects

Square D air conditioning disconnects are used to provide overcurrent protection and a convenient shut-off for air conditioningcompressors. They can also be used for other single-phase, two-wire disconnect applicationssuch as swimming pools and pump houses.These disconnects are available in a variety ofconfigurations, including molded case switches,pullout, fused and not-fused. An exclusivemounting bracket also is available to simplifyinstallation onto stucco or lapped-siding projects.

Metering Equipment

From individual meter sockets to multi-meter-ing, Square D provides a broad line of productsdesigned to meet most utility requirements and fit most applications. Choose from ringor ringless type in a range of ampacities.

Square D® Homeline® Load

Centers and Circuit Breakers

are part of a comprehensive

family of circuit protection

solutions. Like all Square D

products from Schneider

Electric, these innovative

protective devices come

built for easy installation

and reliable operation. And

they’re designed to stand

the test of time.

For more information on our

circuit protection products

or other solutions, please

call your local Square D

distributor or sales office.

Or visit our website at

www.SquareD.com.

Generator Panel

If you live where power outages are frequent, orpotentially dangerous, the Square D generatorpanel is the ideal way to safely connect specific circuits in the home to an alternate power source.

©20

06 S

chne

ider

Ele

ctric

All

Rig

hts

Res

erve

d

2-06Order Number 1170BR9601R2/06

Schneider Electric - North American Operating Division

1415 S. Roselle RoadPalatine, IL 60067Tel: 847-397-2600Fax: 847-925-7500

Homeline Brochure 2006 3/6/06 3:00 PM Page 8