6
FEATURES ' 6 "I12 Digit Display : 1,200,000 Counts ' DEV Basic Accuracy : 0.003596 - Dual Measurements to Perform Two Selected Measurements Simultaneously 1 Bright Macuum Fluorescent Display [VFD} I 'l'l Measurement Functions 3-.10 Math Functions 1 High Resolution : Up to 'l00pA Resolution with DCI and 'lnA with ACI Measurements I Temperature Measurement [RTD 3. Thermocouple] From -200°C -- +'l 820°C 1 High Data Transmission Speed : Up to 2,400 readingsfs Through USB Interface I Standard Interfaces : USB, RS-232C, Digital I [D I Optional Interfaces : GPIB or LAN ' Optional Scanner Card : GDM-SCI [V ch 1: "I6, I ch at 2] ' Free PC Software : DMM-Miewer, LabVlEW Driver Z Simply Reliable

FEATURES · I Standard Interfaces: USB, RS-232C, DigitalI[D I OptionalInterfaces: GPIBorLAN 'OptionalScannerCard : GDM-SCI [Vch1: "I6,I chat 2] 'FreePCSoftware: DMM-Miewer,LabVlEWDriver

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FEATURES · I Standard Interfaces: USB, RS-232C, DigitalI[D I OptionalInterfaces: GPIBorLAN 'OptionalScannerCard : GDM-SCI [Vch1: "I6,I chat 2] 'FreePCSoftware: DMM-Miewer,LabVlEWDriver

FEATURES

' 6 "I12 Digit Display : 1,200,000 Counts' DEV Basic Accuracy : 0.003596- Dual Measurements to Perform Two Selected Measurements Simultaneously1 Bright Macuum Fluorescent Display [VFD}I 'l'l Measurement Functions 3-.10 Math Functions1 High Resolution : Up to 'l00pA Resolution with DCI and 'lnA with ACI MeasurementsI Temperature Measurement [RTD 3. Thermocouple] From -200°C -- +'l 820°C1 High Data Transmission Speed : Up to 2,400 readingsfs Through USB InterfaceI Standard Interfaces : USB, RS-232C, Digital I [DI Optional Interfaces : GPIB or LAN' Optional Scanner Card : GDM-SCI [V ch 1: "I6, I ch at 2]' Free PC Software : DMM-Miewer, LabVlEW Driver Z

Simply Reliable

Page 2: FEATURES · I Standard Interfaces: USB, RS-232C, DigitalI[D I OptionalInterfaces: GPIBorLAN 'OptionalScannerCard : GDM-SCI [Vch1: "I6,I chat 2] 'FreePCSoftware: DMM-Miewer,LabVlEWDriver

Boost Your Measurement Speed & EfficiencyThe GDM-8261A is a high precision 6 V2 digit Digital Multimeter with dual measurement displays, ii measurement functions and i0 mathfunctions at high accuracy (35ppm DC voltage accuracy) to accommodate the most frequently performed parameter measurements invarious application fields today.The GDM-8261A adopts a scanner card, which carries 16 V-Channels and 2 I-Channels, to facilitate the measurements of multiple-testpoints on either a device or multiple devices all at a press ofa button. \X/ith this multi-point measurement capability, the GDM-8261A canbe used as a semi-auto ATE System to increase the throughput of manufacturing test or as a data logger to perform long term monitoringor characterization ofa DUT. A PC Software, DMM-Viewer, is available with GDM-8261A to support multi-channel panel setting and datalogging ofthe scanner card. Besides, a LabVlE\X/ driver is also supported to help user create his/her own virtual instrument on the PCscreen for easy programming. For ATE system measurements or remote control applications, both USB and RS-232C Interfaces areprovided as standard, and either GPIB or LAN can be selected as optional interface for the GDM-8261A.

The GDM-8261A includes all the basic measurement functions thatare required for engineers to handle design, development and

' testing jobs for electronic circuits or products. The basicSHIFT? EXIT SCAN STEP RECALL STDHE MATH dB|T\ dB SENSOR

‘ Q iwiwi ie)+i mi (wt) i-Mi i-»> ll“)L PQWER HATE ‘ COMP V |NTlEXT HEM! FILTER MENU ‘

(Auto) ( 4 ) ( v ) (mow) (mm) REL 2| <MX/MN‘ ( .»~r> J

T '_._ ' I| o‘EN EH _ HANGE_ ,_CHO,CES_v LOCAL measurement function covers a very wide range from 100 |.LA to 10A

measurement functions include voltage, current, resistance, diode,continuity, frequency and temperature. Remarkably, the current

-. " I.

for DC current (in 6 ranges) and from imA to 10A for AC current(in 5 ranges). In addition, the GDM-8261A features 10 Math functions(dBm, dB, compare and other mathematical operations) toaccommodate specific measurement requirements and complexmeasurement applications.

-|St Disphy 2nd Display

>n< \ \ACV DCV ACI

'\DCI Hz/P 2W/4W"*'\ J

Un< \ \ \ \ JAC I \ \ K \ ’\

\DCI \ \ R '\Hz/P ’\ \ K K R

zw/4w='= — ’\

Unlike most ofthe “dual disp|ay” digital multimeters, which showtest result on the primary display and range information on thesecondary display, the GDM-8261A is able to perform twomeasurement functions simultaneously and shows the test resultson primary display and secondary display respectively. tasks.

The GDM-8261A supports an almost unlimited number ofmeasurement combinations ofdual measurement functions,besides the normal test result and range information displays,greatly increases the test speed of multi-function measurement

C. HIGH MEASUREMENT RESOLUTION & HIGH SAMPLING RATE

The GDM-8261A offers an exceptionally high resolution ofO.l uV

Mode Resohltion DCV/DCI/ResistanceMeasurement Speed

Fast 4‘/Zdigits 2,400 readings/second

Slow 6‘/2 digits 30 readings/second

Medium 5‘/Zdigits 600readings/second

for voltage measurement, l0OpA for DC current measurement, inAfor AC current measurement, and 100 |.L Q for Resistancemeasurement. This level of resolution and accuracy becomes a mustfor the precision measurements in specific applications. In addition,the GDM-8261A is capable of acquiring 30 measurement readings/sat the display resolution of4 V2 digits and 2,400 readings/s at thedisplay resolution of6 Z digits. The fast acquisition rate oftheGDM-8261A adequately meets today's measurement demands.

Page 3: FEATURES · I Standard Interfaces: USB, RS-232C, DigitalI[D I OptionalInterfaces: GPIBorLAN 'OptionalScannerCard : GDM-SCI [Vch1: "I6,I chat 2] 'FreePCSoftware: DMM-Miewer,LabVlEWDriver

2W connection 4W connectionI

soc‘INPUT w 4W INPUTV W_"_ ssnss. v w-»

c0M ....§9.’Y‘.............

‘\......

\.......¢'

The GDM-8261A offers two methods, both 2-wire and 4-wire, forresistance measurements. The 2-wire measurement is most commonlyused for resistance measurement in the range from 10052 to 10k§2.Whereas the 4-wire connection is normally applied for resistancemeasurement at a value lower than 100Q. When applied, 4-wiremeasurement automatically compensates the test lead resistance andconnector contact resistance to get an accurate measurement result.

The GDM-8261A is able to acquire and record 2 ~ 9999measurement readings for the “store” and “recall” functions.This allows an immediate observation ofthe maximum, minimum,average or standard deviation values of all the recorded datawhenever the data acquisition stops.

The “Math” function ofGDM-8261A includes four mathematicaloperations for measurements: MX+B, 1/X, Percentage and Stats.“MX+B" multiplies the measurement reading (X) by a factor (M) andadds/subtracts an offset value (B) to calculate linear offsets or scalesThe “1/X” function divides 1 by the measurement reading (X),calculating the inverse ofthe reading. The “Percentage” functioncalculates the ratio ofthe measured value to a target value using the

19 - - - - _~— 'G1 , . , .__ —1_‘ Q .i:|‘|:ii|7| Fr |:|l|:|ll|:|1|:| 1:1 Gilli 1:1 1-M71»; .: I---H-1+1-~-I—__.. Iélwla-X-Xe-X»--1'-I-\-»1 I-I»---X4-Ia-X-\-'1»--X-X+Zl

uinu;*0

O

S

K, ,...1.,.,...X..I.q.,.Xs.1.T, l-1"IT»!-T-1?»!-“F1-TtT>1-T-Il~-1*-1-Y-1-slsleliL—,|:|;|:| i=1 lglilgl lgl Iglilgl; iigngu :5: igiirgi l:l igiilgij- .6] . lei I:liI:IiI:' level

1

H-u

following equation: (Reading X — Reference)/Reference x 100%. The“Stats” function makes statistical calculations continuously or by a

user-defined measurement counts. The statistical calculationsinclude Maximum, Minimum, Average and Standard deviation. Withthese mathematical operations, the GDM-8261A makes complexmeasurements quick and easy without the complexity of manualcalculations.

G. TEMPERATURE MEASUREMENT

Cold junctionpoints

Hot junctionCH + \ Material A point

C ._—POCH — I Material B

4 Extension, . wires

-J1

The GDM-8261A performs temperature measurement accommodating popular thermocouple types are supported for temperaturea wide range oftemperature sensors ofeither thermocouples or RTD measurement on the GDM-8261A. For RTD sensors, the GDM-8261A(Resistive Temperature Detectors). For thermocouples, the GDM-8261A calculates the voltage fluctuation arisen from the resistance variationuses voltage measurement terminals as the thermocouple input and due to temperature change. Either front panel terminals or scannercalculates the temperature from the voltage fluctuation. Most ofthe card terminals can be used as the input for temperature sensor.

Page 4: FEATURES · I Standard Interfaces: USB, RS-232C, DigitalI[D I OptionalInterfaces: GPIBorLAN 'OptionalScannerCard : GDM-SCI [Vch1: "I6,I chat 2] 'FreePCSoftware: DMM-Miewer,LabVlEWDriver

T _" ’ -_ i i_- T‘

l ifgii H 16 cmimsi.hr fig asi:v.2i\ _ SCANNER"I " Ei_iQlT£i, H79 I4: RS232

at C €Q g ‘iii

|| I‘ :-.~i1\.E>-.\i'\.i-i 0 3 . . . ' . .

For system applications, the GDM 8261A provides USB interface

IOI IGI III III III III III

II IIP

and RS-232C interface as standard. Up to 2,400 readings/s ofdata

can be transferred over USB in ASCII format. Either GPIB or LANinterface is available as an option to support the ATE systemscurrently in use.

DMM-Viewer

‘.4*

T‘ ,’ -'-___,

w I

? Z ' E ‘g 1.1, .»=_-1*-"S-‘5(.§,»_:%_;r‘-gs ‘-

- //'E.

//C/ / /

\ "T

fl il.\ '../'ox . _ /

3%?‘*;__ l“\\~,

The optional scanner card, with a field-installable design, is aself-contained multipoint measurement solution. This approach

eliminates the complexities of software development for multi-point measurement and data processing. The scanner card allowsusers to effectively measure multiple channels connected to asingle GDM-8261A.

lmflfl

l5U}l1

SHIFUENII semi STEP F-sf;-i1 5*-'-Pr MAT"! _iii5ir _dB _ Sizsisoa. E) ow; -sci; n_c_1-3 1-'4W_| -EM) i-ism") TEMP)

s‘mi=.T mm cow |N1'.'Bfi F‘EL§ nuen_ AUTO) Q) T’) (nun) TRIO); REL.) uxmn; 2ND)

- JI. amen L remiss J L_ci-aces) LOCALF Savobnta r‘ =-».|-mm 11-.

ifilfliififi llflhifl} i 1501!“? ‘Su_IQI' lslnflflnilifll linflll

sis-iani I JO

lulu:I0

nu:A-ii»:

. I0li€:|ocv“IIDIIIIN II

weat IW

hr! DISPLAYSHQW urine ci-mm iwi: nun ciumi Cll\N:IiMi:

CIIIIHCIIIIHOIIII

Fm I550Ill

Clllr

Cd

Ii. ._ ..._ ..............i_..-i it-1lT==-I Nw Ir-1 an lmaizia-mm:was H"i°;1lIl1l"E@Ei1_*_1L)J_A\2!§fi__)i_ _ mum mm aiiiumiiii-ass aw [mum ; '€°l""m"'°*

Slaarfen inncelaunnrn miismmsiiasall ziw immnl "PEP!-l\’-l5"°\l'""1 “!!*§~Ii9!'-‘£52951 1" “WW _ @',],h "" r" numnazsuow

°*‘“"““°"° Emma aunm miggmiggss aw loggga 'h"~llimam mime aiomneiusss aw ammo Sm h 5¢\Ii1‘ITiII

cimsm iamnlmnnae Z!'|0flflQillJ6r§| aw imzisml ' "i' °*l nun gunEllliil miinm mmuiamiiussa aw imlisn [mm _[ my; I ho 5 Ii

E mm new a§i§»m'1n?=s5ij*rT"im3iaai _ '"'"' “H * _Imus mm-in wv:|nr>c§$r nu: rrir-1M0 ' i

~-I I. llillrfl-l19fl:|_|T'lVlllpullIl-!l1fi:l_1_|Sil\!iDATA|"' San Sup l

Control & Data Acquisition Data Reload & Graph

LabVlEW Driver

Panel Setting & Data Acquisitionfor All Scanner Channels

III

noun Commeniis

‘E?£*‘?‘f‘i‘?“1"i'¥"°,-‘f‘PF"°”-"‘"¥?f"3 .. _ QEEIah aw Qvmawlaaarfivaw Hilifllilfflvlli _ ZU _., - ~ _( _()——_U , _( .? t.

A

l¢>l@] _,)|| @“h°'Q|J_,)24p1App1|:ahonFont )1; Q. P1

arlflfll‘? Close

9251 8281 ezsi a2s1 szsi seerfirst “Bi 2%? ii;-$5 §9r‘fi:i.:f

fill? l‘-FE)»(

iiz;-< ii-as I-I as :-. asUnit Uolt Curr CurrHE 9 FIE '7 DC '7 FIE’?

N H’?-‘ :i=@<* I4-HS H"Ffi‘ liiillfiUolt |.'oll: Curr Curr Uolt Unit Curr CurrDC '7 DC ? FIE '? DC FTC DC FIC

FEES?

IIEIHW asM wi m

<I

K‘)

%Fe

liI.II$l]]!i$

Ii

)

For the convenience of remote control and long time data acquisition,

a free software, DMM-Viewer, is supported with the C-DM-8261A. Thissoftware allows user to remotely control the GDM-8261A without the

need to give commands or to develop programming software. DM M-

Viewer‘s human interface resembles the GDM-8261A front panel, whichsignificantly shortens the user’s learning time. For the data capturethrough a PC, the software allows user to continuously observe themeasurement results before saving them into a file. Further more,

the saved files can be loaded and viewed as a graph for data analysis.

When GDM-8261A works with scanner card for multi-pointmeasurements, the DM M-Viewer allows user to easily select the

measurement function and range for each channel and start

acquiring measurement data promptly. The GDM-8261A LabV|EW

driver is also available for free download. With this driver, the useris able to create a virtue instrument on the PC for the instrument

control. With DMM-Viewer & Lab\/IEW driver, the GDM-8261Abecomes a high value semi-auto ATE system without furthersoftware/hardware investments.

Page 5: FEATURES · I Standard Interfaces: USB, RS-232C, DigitalI[D I OptionalInterfaces: GPIBorLAN 'OptionalScannerCard : GDM-SCI [Vch1: "I6,I chat 2] 'FreePCSoftware: DMM-Miewer,LabVlEWDriver

Temperature Coefficient

0",-1s°c /23°-55 cFUNCTION

DC VOLTAG E

RESISTANCE (*2)

DC CURRENT

CONTINUITYDIODE TEST (*3)

Range (*1)

100.0000 m V1 .000000 V10.00000 V100.0000 V1000.000 V

100.0000 Q1.000000 kQ10.00000 kQ100.0000 kQ1.000000 M Q10.00000 M Q100.0000 M Q100.0000 LIA1.000000 mA10.00000 mA100.0000 mA1.000000 A10.00000 A1000.000Q1 .000000 V

Resolution

0.1)uV1;.zV100V0.1mV1mV

100,001m()

10mQ100mQ

1Q10Q

100Q100pA1nA10nA

0J;1A1;1A100A0.00101rzV

Test Currentor etc.

10MQ or >10GQ10MQ or >10GQ11.11MQi1%10.1 MQi1%10.1MQi1%

1mA1mA1000A10uA350A350nA350 nA//10MQ<0015V<0J5V<007V<07V<08V<05V

1 mA1 mA i==-4)

Accuracy: 1: (% of reading + % of range )for 1-hour warm-up at 6 %z digits, slow mode

24 Hours23°C =i=1°C

0.0030 + 0.00300.0015 + 0.00040.0020 + 0.00060.0020 + 0.00060.0025 + 0.00060.030 + 0.0300.020 + 0.0050.020 + 0.0050.020 + 0.00510.020 + 0.00100.0150 + 0.00100.3000 + 0.01000.010 + 0.0200.007 + 0.0050.005 + 0.0100.010 + 0.0040.050 + 0.0060.100 + 0.0080.002 + 0.0300.002 + 0.010

90 Days23°C :I: 5°C

0.0040 + 0.00350.0020 + 0.00050.0030 + 0.00070.0035 + 0.00060.0044 + 0.00100.008 + 0.0040.008 + 0.0010.008 + 0.0010.008 + 0.0010.008 + 0.0010.020 + 0.0010.800 + 0.0100.04 + 0.0250.03 +0.0050.03 + 0.0200.03 +0.0050.08 + 0.0100.12 +0.0080.008 + 0.0300.008 + 0.020

1 Year23°C =1: 5°C

0.0050 + 0.00350.0035 + 0.00050.0048 + 0.00070.0081 + 0.00060.0090 + 0.00100.010 + 0.0040.010 + 0.0010.010 + 0.0010.010 + 0.0010.010 + 0.0010.040 + 0.0010.800 + 0.0100.05 + 0.0250.05 +0.0050.05 + 0.0200.05 +0.0050.10+ 0.0100.15 +0.0080.010+0.0300.010+ 0.020

0.0005 + 0.00050.0005 + 0.00010.0005 + 0.00010.0005 + 0.00010.0005 + 0.00010.0008 + 0.00050.0008 + 0.00010.0008 + 0.00010.0008 + 0.00010.0010 + 0.00020.0030 + 0.00040.1500 + 0.00020.002 + 0.00300.002 + 0.00050.002 + 0.00200.002 + 0.00050.005 + 0.00100.005 + 0.00080.001 + 0.0020.001 + 0.002

Note :

r"""\\r"""\\r"""\\r"-‘Hu_~.J_\I_u_¢|1|FlnAcoI\.)—I

‘\-u--|4‘\-u--01"-u--0""-u--I4

r""'\\

‘-1.'\ "'--J‘---I

across a diode junction.

20% overrange on all ranges, except 1000 \/dc/750\/ac, 10A range and Continuity.Specifications are for 4-wire ohms function, or 2-wire ohms using REL function.Accuracy specifications are for the voltage measured at the input terminals onlyVariation in the current source will create some variation in the voltage drop

I"-"hI""'\\\lJrf"- O'\Lri

"H--I4‘"1--I

r-mr-mu_-u_q¢nI-DO9'--.-I'---4

Specifications are for sinewave input >5% of range.750 Vac range limited to 100 kHzTypically 30% of reading error at 1 MHz.Input >100 mV. For 10 m\/ to 100 mV inputs, multiply % of reading error x10Specifications do not include probe accuracy and relative to simulated junction

Page 6: FEATURES · I Standard Interfaces: USB, RS-232C, DigitalI[D I OptionalInterfaces: GPIBorLAN 'OptionalScannerCard : GDM-SCI [Vch1: "I6,I chat 2] 'FreePCSoftware: DMM-Miewer,LabVlEWDriver

TRUE RMSAC VOLTAG E (*5)

TRUE RMSAC CURRENT (*5)

100.0000mV 0.1/,tV 3Hz~5Hz5Hz~10Hz10Hz~20kHz20kHz~50kHz50kHz~100kHz100 kHz~300kHz(*7)

1.00+0.030.35 +0.030.04+0.030.10+0.050.55 +0.084.00+0.50

1.00 + 0.040.35 + 0.040.05 + 0.040.11 + 0.050.60 + 0.084.00 + 0.50

1.00 + 0.040.35 + 0.040.06 + 0.040.12 + 0.050.60+ 0.084.00+ 0.50

AC SPECIFICATIONSFUNCTION Range (*1) Resolution Frequency 24 Hours 90 Days 1 Year Temperature Coefficient

or etc. 23°C 1 1°C 23°C 1 5°C 23°C 1 5°C 0°-18°C /28 -55°C

0.100+ 0.0040.035 + 0.0040.005 + 0.0040.011 + 0.0050.060+ 0.0080.200+0.020

1 .000000V~750.000 V (*5)

1.000000 mA

1,uV~1mV

1nA

3Hz~5Hz5Hz~10Hz10Hz~20kHz20kHz~50kHz50kHz~100kHz100kHz~300kHz(*7)3Hz~5Hz5Hz~10Hz10Hz~5kHz5kHz~10kHz

1.00+0.020.35 +0.020.04+0.02O.10+0.040.55 +0.084.00+0.5O1.00+0.040.30+0.040.10+0.040.20+0.25

1.00+0.030.35 +0.030.05 +0.030.11 + 0.050.60+0.084.00+0.501.00+0.040.30+0.040.10+0.040.20+0.25

1.00+0.030.35 +0.030.06+0.030.12+0.050.60+0.084.00+0.501.0+0.040.3+0.040.1 +0.040.2+0.25

0.100+0.0030.035 +0.0030.005 +0.0030.011 + 0.0050.060+ 0.0080.200+0.020

0.100+ 0.0060.035 + 0.0060.015 + 0.0060.030+ 0.006

10.00000 mA 10nA 3Hz~5Hz5Hz~10Hz10Hz~5kHz5kHz~10kHz

1 .10+0.060.35+0.060.15+0.060.35+0.70

1.10+0.060.35+0.060.15+0.060.35+0.70

1.10+0.060.35+0.060.15+0.060.35+0.70

0.200+ 0.0060.100+ 0.0060.015 + 0.0060.030+ 0.006

100.0000 mA 100nA 3Hz~5Hz5Hz~10Hz10Hz~5kHz5kHz~10kHz

1.00+0.040.30+0.040.10+0.040.20+0.25

1.00+0.040.30+0.040.10+0.040.20+0.25

1.00+0.040.30+0.040.10+0.040.20+0.25

0.100+ 0.0060.035 + 0.0060.015 + 0.0060.030+ 0.006

1 .000000 A 1|.1A 3Hz~5Hz5Hz~10Hz10Hz~5kHz5kHz~10kHz

1.00+0.040.30+0.040.10+0.040.35+0.70

1.00+0.040.30+0.040.10+0.040.35+0.70

1.00+0.040.30+0.040.10+0.040.35+0.70

0.100+ 0.0060.035 + 0.0060.015 + 0.0060.030+ 0.006

FREQUENCY (*8)PERIOD

TEMPERATURE(RTD

TEMPERATURE(THERMOCOUPLEDISPLAY

POWER SOURCEINTERFACE

DIMENSIONS &WElG

10.00000 A

100.0000 mV~750.000 V(*5)

-200 °C-600 °C

-200 ~ +1372 “C-50 ~ +1870 OCVFD, Two Colors Dis

10pA

0.002°C

0.003°C0.01°C

PlayRS-232C, USB, Digital I/OAC 100V/120V/220V/240V110%, 45 Hz ~ 66 Hz and 360 Hz ~ 440 Hz

3Hz~5Hz5Hz~10Hz10Hz~5kHz5kHz~10kHz

3 Hz~5 Hz5 Hz~10 Hz10 Hz~40 Hz40 Hz~300 kHz

(J/K/N/T/ETYPQ)(R/5/BTYPQ)

265(W) x 107(H) x 350(D) mm, Approx. 3.1 kg

1.10+0.060.35+0.060.15+0.060.35+0.70

0.10.05

0.006

1.10+0.060.35+0.060.15+0.060.35+0.70

0.10.05

1.10+0.060.35+0.060.15+0.060.35+0.70

0.10.05

0.03 0.03 0.030.01 0.01

- - 0.06°C (typical)

0.100+ 0.0060.035 + 0.0060.015 + 0.0060.030+ 0.006

0.0050.0050.0010.001

_ _ 0.2°C (typical) 0.004 °C / °C (typical)i.0°c 0.14 °c / "c

* Three-year warranty, excluding accessories.

ACCESSORIESQuick star guide x 1, Power cord x 1, Test lead GTL-117 x 1,USB cable GTL-247 x 1, CD x 1 (including complete user manual,upgrade program and PC software DMM-Viewer), Calibration keyGDM-01 x 1 (for firmware upgrade)

ORDERING INFORMATIONGDM-8261A 6 Z Digit Dual Measurement Multimeter

Specifications subject to change without notice. DM-3261A(_‘, D1 BH

OPTIONOpt. 01 GDM-SCI Scanner Card (V ch x 16, I ch x 2)Opt. 02 GPIB CardOpt. O3 LAN C8I'Cl * Either GPIB or LAN can be installed on each GDM-8261.

OPTIONAL ACCESSORIESGTL-108A 4W Type test lead C-TL-248 G Pl B Cable, Approx. 2mGTL-232 RS-232C Cable, 9-pin female to 9-pin, null modem for computer,

Approx. 2mFREE DOWN LOADPC Software DMM-VIEWER, RS-232C/USB Interface Supported

LabVIEW Driver, RS-232C/USB/GPIB Interface SupportedDriver USB Driver

Global Headquarters U.S.A. SubsidiaryGOOD WILL INSTRUMENT CO., LTD. INSTEK AMERICA CORP.No.7-1, jhongsing Road, Tucheng Dist., New Taipei City 236, Taiwan 3661 Walnut Avenue Chino, CA 91710, U.S.A.T +836-2-2268-0389 F +886-2-2268-0639 T +1 -909-591 8358 F +1 -909-591 2280E mail: [email protected] E-mail: [email protected]

China Subsidiary japan SubsidiaryGOOD WILL INSTRUMENT (SUZHOU) CO., LTD. INSTEK ]APAN CORPORATIONNO. 69, Lushan Road, Snd, Suzhou jiangsu 215011 China 4F, Prosper Bldg, 1-3-3 lwamoto-Cho Chiyoda-Ku,T +86-512-6661-7177 F +86-512-6661-7277 Tokyo 101-0032 JapanE mail: [email protected] T +81-3-5823-5656 F +81-3-5823-5655

E-mail‘ info@instek co jp

Malaysia Subsidiary Korea Subsidiary Gioooo WILL INSTRUMENT (M) SDN. BHD. coop WILL INSTRUMENT KOREA co., LTD. Simpb, Rename27, Persiarari Mahsuri 1/1, Sunway Tunas, Room No.805, Ace Hightech-City B/D1Dong,11900 Bayan Lepas, Penang, Malaysia Mullae-Dong 3Ga 55-20, Yeongduengpo-Gu, Seoul, KoreaT +604-6309988 F +604-6309989 T +82-2-3439-2205 F +82-2-3439-2207 'E mail: [email protected] E-mail : [email protected] W W W‘ gW| n S k ' C 0 m