Features• Self contained in lockable cabinet

• 24 VDC remote power supply

• Power-limited individually protected outputs

• Two input/control circuits (from FACP notification appli-ance circuits) are electrically isolated from outputs.Input 1 controls Output 1 and Output 2. Input 2 controlsOutput 3 and Output 4

• Two Style Y/Style Z notification appliance circuits (out-puts 1 and 3)

• Two Style Y circuits (outputs 2 and 4 which could beconfigured permanently ON (non-resettable))

• 4.0 amp continuous output

• 6.0 amp full load output

• Suitable for powering 4-wire smoke detectors

• Integral battery charger

• Up to 7.0 AH batteries in FCPS-24 cabinet

• Fully supervised power supply, battery, and notificationappliance circuits

• Earth fault detection (selectable)

• A.C. fail trouble contact reporting immediate, delayed8, or 16 hours (selectable)

• Fixed terminal blocks for field wiring capable of accept-ing up to 12 AWG wire

• Normally closed output trouble contacts

• Suitable for 60 hour standby when outputs are used asnotification circuits

Applications

The FCPS-24 and FCPS-24E are compact, cost effec-tive, remote power supplies with battery chargers. TheFCPS-24(E) consists of a regulated and filtered 24 VDCoutput that may be configured to drive four notificationappliance circuits (four Style Y, or two Style Z and twoStyle Y). Alternately, all outputs could be used as anycombination of resettable/non-resettable power outputs.The FCPS-24(E) also contains a battery charger capableof charging up to 7.0 Amp Hour batteries.

Technical InformationAC Power:

FCPS-24:. . . . . . . . . . . . . . . . . . . 120 VAC, 50/60 HzFCPS-24E:. . . . . . . . . . . . . . 220/240 VAC, 50/60 Hz

Wire Size: . . . Minimum #14 AWG with 600 V insulationBattery:

Normal Charge Voltage: . . . . . . . . . . . . . . . . . 27.6 VMaximum Charge Current:. . . . . . 250 mA MaximumMaximum Battery Capacity: . . . . . . . . . . . . . . 7.0 AH

DIMENSIONS

APPLICATION EXAMPLES

Example 1: Expand notification appliance power an addi-tional 6.0 amps. Use up to 4 Class B (Style Y) outputs or2 Class A (Style Z) and 2 Class B (Style Y) outputs.

In this example, the FACP notification appliance circuitswill activate the FCPS-24 when on (polarity reverses).Trouble conditions on the FCPS-24 are sensed by theFACP through notification appliance circuit #1.

Example 2: Use the FCPS-24 as a 4 amp regulatedpower supply. The output may be selected as resettableor non-resettable.

A resettable FCPS output is created by tying the reset-table output from the FACP to one or both of the FCPS-24 inputs. A non-resettable output is created simply bycutting an on board resistor. For addressable unit appli-cations, use a monitor module to sense the trouble sta-tus of the FCPS-24 via the trouble contacts. Use a FreeInitiating Zone or an Addressable monitor module tomonitor the FCPS for trouble.

DETECTION AND CONTROL EQUIPMENT

DATA SHEET

FCPS-24/FCPS-24EREMOTE POWER SUPPLY

PC2001177

One Stanton StreetMarinette, WI 54143

FACPFCPS-24(E)

NAC #1SILENCEABLE

NAC #2NON-SILENCEABLE

ELRINPUT 1

SILENCEABLEHORNS

NON-SILENCEABLESTROBESINPUT 2

ELR

14.5 IN.(368 mm)

2.75 IN.(70 mm)DEEP

15 IN.(381 mm)

ALL OUTPUTSREGULATED + 24 VDC

RESETTABLE POWER

NON-RESETTABLEPOWER

END OFLINE RELAY

INPUT 1

TROUBLECONTACTS

INPUT 2

•R175 CUT

•R176 CUT

OUTPUT 1

OUTPUT 2

OUTPUT 3

OUTPUT 4

+ 24VRESETTABLEPOWER

SLC LOOP

FACP

MONITORMODULE

Page 2: FCPS-24/FCPS-24E REMOTE POWER SUPPLY - … · Features • Self contained in lockable cabinet • 24 VDC remote power supply • Power-limited individually protected outputs •Two

Technical Information (Continued)

Example 3: Use addressable control modules to activatethe FCPS-24(E) instead of FACP notification appliancecircuits (compare with example 1). This typically allowsfor mounting the FCPS-24(E) at greater distances awayfrom the FACP while expanding system architecture.

FCPS-24(E) troubles are sensed by control module #1 inOff state. Both control modules should be close nippledto FCPS-24(E) cabinet.

Listings and Approvals*UL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S635California State Fire Marshal (CSFM) . . 7315-0028:178MEA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387-94-E

* Listings and Approvals are under NOTIFIER a Division of Pittway Corporation. Listingswith CSFM and MEA are for FCPS-24 only.

Ordering InformationShippingWeight

No. Description lb. (kg)

418563 FCPS-24F Remote Power 25 (11.3)Supply, 120 VAC, Red

418564 FCPS-24FE Remote 25 (11.3)Power Supply, 220 VAC, Red

417692 Battery Pack, 7 AH, 13 (5.9)24 VDC (two-12 volt batteries)

417699 EOL Power Supervision Relay 1 (0.45)

TERMINAL DESIGNATIONSTO TRANSFORMER #2

CUT JP1 TO USE A LISTED EXTERNAL BATTERY CHARGER.

CUT R134 AND R76 TO ENABLE TROUBLE REPORTING ONCONTROL INPUT #1.

CUT R175 TO MAKE OUTPUT #2 CONSTANT ON 24 VDC.

CUT R176 TO MAKE OUTPUT #4 CONSTANT ON 24 VDC.

TO TRANSFORMER #1

EA

RT

H

TB1

P1

P2

JP1

JP2

BATTERY FUSE 10A 3AG SLOW BLOW

R27

TB2

R175

R76

R176

TB4

2.2

K

2.2

K

1 2 3 4 5 6 7 8 9 10 11 12

R63

TB3R134

D31

1 IN +

2 IN – (Control Input #1 from FACP)

3 OUT +/TROUBLE CONTACT

4 OUT –

5 TROUBLE CONTACT

6 IN +

7 IN – (Control Input #2 from FACP)

8 AUXILIARY OUTPUT (+24 VDC, 10 mA max)

9 AUXILIARY OUTPUT RETURN

BA

TT

ER

Y(+

)

BA

TT

ER

Y(—

)

7 A

H, 2

4 V

DC

AC

ON

AC

FA

ILU

RE

/EA

RT

H F

AU

LT

BA

TT

ER

Y/C

HA

RG

ER

TR

OU

BLE

OU

TP

UT

1 T

RO

UB

LE

OU

TP

UT

2 T

RO

UB

LE

OU

TP

UT

3 T

RO

UB

LE

OU

TP

UT

4 T

RO

UB

LEO

UP

UT

1 +

(Sty

le Y

/Z)

OU

TPU

T1

-(S

tyle

Y/Z

)

OU

TPU

T1

+ (S

tyle

Z)

OU

TPU

T-

(Sty

le Z

)

OU

TPU

T2

+ (S

tyle

Y)

OU

TPU

T2

-(S

tyle

Y)

OU

TPU

T3

+ (S

tyle

Y/Z

)

OU

TPU

T3

-(S

tyle

Y/Z

)

OU

TPU

T3

+ (S

tyle

Z)

OU

TPU

T3

-(S

tyle

Z)

OU

TPU

T4

+ (S

tyle

Y)

OU

TPU

T4

-(S

tyle

Y)

AC

NE

UT

RA

L

AC

HO

T

INPUT 1

FCPS-24(E)

AUXILIARYOUTPUT

INPUT 2

OUTPUT 1

OUTPUT 2

OUTPUT 3

OUTPUT 4

SLC LOOP

FACPADDRESSABLE

CONTROL MODULE #1

CONTROL MODULE #2