12
FCP03 CONNECTION TO ellard TUBE MOTORS 'JM' SERIES FIRE SHUTTER OPERATORS APOLLO SMOKE AND HEAT DETECTORS 1

FCP03 CONNECTION TO ellard...• Panel will now show "Engineers set up fast set 1 press the "up" button until the display shows "fast set 5" then press "select" • Display will now

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FCP03 CONNECTION TO ellard...• Panel will now show "Engineers set up fast set 1 press the "up" button until the display shows "fast set 5" then press "select" • Display will now

FCP03 CONNECTION TO

ellardTUBE MOTORS

'JM' SERIES FIRE SHUTTEROPERATORS

APOLLO SMOKE AND HEATDETECTORS

1

Page 2: FCP03 CONNECTION TO ellard...• Panel will now show "Engineers set up fast set 1 press the "up" button until the display shows "fast set 5" then press "select" • Display will now

2

FCP03 INSTRUCTION(FAST SET 1 - SOLENOID DROP)

For JM pre-wired operators with controlled descent closure bysolenoid release

· Wire operator, push buttons, panel and solenoid as per drawing· Connect mains and fit panel battery connector blocks· Rolling display will flash "Ellard Fire Panel"· panel is ready to program when "mains" and "set" light are

steady and display is showing a rolling "- - -"· Test operator set limits and observe time taken to fully open and

close

To program for solenoid drop

· Press and hold all three buttons on the front of the panel until theinternal light flashes once (approx 5 secs)

· Panel will now show "Engineers set up" "fast set 1" press"select"

· Display will now show "full close delay" (this is the delay timebefore the door starts to close once the fire alarm has beenactivated) display will show "mins" then "000" Use the "up" and"down" buttons to enter the desired time, then press "select", Ifthe delay time is shorter than 1 min press "select", display willnow show "secs" then "000" use the "up" and "down" buttonsto enter the desired time, then press "select"

· Display will now show "full close drop" (this is the time it takesthe door to fully close) enter any times as described aboveDisplay will now show "re-open time" (this is the time it takes thedoor to fully open "automatically" once the fire alarm signal isremoved, this should be set the same as "full close drop") enterany times as described above, should the door wished to beraised by pressing the push button only press the "select" buttontwice only

· The panel will flash once to show the program is completed andthe display will return to its set position showing a rolling "- - -"

Page 3: FCP03 CONNECTION TO ellard...• Panel will now show "Engineers set up fast set 1 press the "up" button until the display shows "fast set 5" then press "select" • Display will now

3

For Tube Motors or JM pre-wired operators with drive down closureunder power· Wire operator, push buttons, panel and solenoid as per drawing· Connect mains and fit panel battery connector blocks· Rolling display will flash "Ellard Fire Panel"· panel is ready to program when "mains" and "set" light are

steady and display is showing a rolling "- - -"· Test operator set limits and observe time taken to fully open and

close

To program for drive down

· Press and hold all three buttons on the front of the panel until theinternal light flashes once (approx 5 secs)

· Panel will now show "Engineers set up" "fast set 1" press the"up" button until the display shows "fast set 4" then press"select"

· Display will now show "full close delay" (this is the delay timebefore the door starts to close once the fire alarm has beenactivated) display will show "mins" then "000" Use the "up" and"down" buttons to enter the desired time, then press "select", Ifthe delay time is shorter than 1 min press "select", display willnow show "secs" then "000" use the "up" and "down" buttonsto enter the desired time, then press "select"

· Display will now show "full close drop" (this is the time it takesthe door to fully close) enter any times as described aboveDisplay will now show "re-open time" (this is the time it takes thedoor to fully open "automatically" once the fire alarm signal isremoved, this should be set the same as "full close drop") enterany times as described above, should the door wished to beraised by pressing the push button only press the "select" buttontwice only

· The panel will flash once to show the program is completed andthe display will return to its set position showing a rolling "- - -"

FCP03 INSTRUCTION(FAST SET 4 - DRIVE DOWN UNDER POWER)

Page 4: FCP03 CONNECTION TO ellard...• Panel will now show "Engineers set up fast set 1 press the "up" button until the display shows "fast set 5" then press "select" • Display will now

4

For Tube Motors or JM pre-wired operators to close in 2 stages· Wire operator, push buttons, panel and solenoid as per drawing· Connect mains and fit panel battery connector blocks· Rolling display will flash "Ellard Fire Panel"· panel is ready to program when "mains" and "set" light are steady and

display is showing a rolling "- - -"· Test operator set limits and observe time taken to fully open and close

To program for 2 stage closing· Press and hold all three buttons on the front of the panel until the

internal light flashes once (approx 5 secs)· Panel will now show "Engineers set up" "fast set 1" press the "up"

button until the display shows "fast set 5" then press "select"· Display will now show "part close delay" (this is the delay time before

the door starts to close once the fire alarm has been activated) displaywill show "mins" then "000" Use the "up" and "down" buttons to enterthe desired time, then press "select", If the delay time is shorter than 1min press "select", display will now show "secs" then "000" use the"up" and "down" buttons to enter the desired time, then press "select"

· Display will now show "part close drop" (this is the time it takes thedoor to drive down to smoke cutain height) enter any times as describedabove

· Display will now show "full close delay" (this is the delay time the doorwill remain at smoke cutain height before fully closing) enter any timesas described above

· Display will now show "full close drop" (this is the time it takes thedoor to close to fully close from smoke curtain height) enter any timesas described above

· Display will now show "re-open time" (this is the time it takes the doorto fully open "automatically" once the fire alarm signal is removed, thisshould be set the same as "full close drop") enter any times asdescribed above, should the door wished to be raised by pressing thepush button only press the "select" button twice only

· The panel will flash once to show the program is completed and thedisplay will return to its set position showing a rolling "- - -"

· If power is lost during closing the solenoid will be activated (if fitted) andthe shutter will drop in acontrolled descent manner

FCP03 INSTRUCTION(FAST SET 5 - 2 STAGE CLOSING)

Page 5: FCP03 CONNECTION TO ellard...• Panel will now show "Engineers set up fast set 1 press the "up" button until the display shows "fast set 5" then press "select" • Display will now

5

SE

LEC

TAB

LEFI

RE

ALA

RM

SIG

NA

L(N

/OV

OLT

FR

EE

CO

NT

AC

TS

HO

WN

)R

JMP

OW

ER

SU

PP

LYC

ON

NE

CTI

ON

FOR

3P

HA

SE

OP

ER

ATO

RS

ANIN

DE

PE

ND

EN

TS

UP

PLY

INC

LUD

ING

AN

EU

TR

AL

CO

NN

EC

TIO

NM

US

TB

EIN

STA

LLE

D

FOR

1P

HA

SE

OP

ER

ATO

RS

THE

MO

TOR

SU

PP

LYC

AN

BE

SU

PPLI

ED

VIA

ANIN

DE

PE

ND

EN

TS

UP

PLY

OR

TAK

END

IRE

CT

LYFR

OM

TER

MIN

ALS

51(E

),52

,(N

)AN

D53

(L)

RE

D

YEL

LOW

PU

RP

LE

BLA

CK

RED

Mot

orC

ont

rolC

able

24v

d.c

.Sol

enoi

dC

able

230v

Sol

eno

idR

eset

Cab

le

BR

AK

ER

ELE

AS

ESO

LEN

OID

'JM

'SE

RIE

SO

PE

RA

TOR

230V

MA

INS

SU

PP

LY

(Ke

y-s

wit

ch

sho

wn

-S

AP

Z1-

2T)

2 1PP

GE

NE

RA

LC

ON

NE

CTI

ON

FO

R'J

M'S

ER

IES

FIR

ES

HU

TT

ER

OP

ER

ATO

RS

(SO

LEN

OID

AN

DD

RIV

ED

OW

NC

LOS

ING

-F

AS

TS

ET

S1

+4)

(Pu

sh

Bu

tto

nS

tatio

nE

LS

3N

Su

pp

lie

dw

ith

'JM

'op

erat

or)

Page 6: FCP03 CONNECTION TO ellard...• Panel will now show "Engineers set up fast set 1 press the "up" button until the display shows "fast set 5" then press "select" • Display will now

6

1stS

TA

GE

CLO

SIN

GS

ELE

CTA

BLE

FIR

EA

LAR

MSI

GN

AL

(N/O

VO

LTF

RE

EC

ON

TA

CT

SH

OW

N)

R

JMP

OW

ER

SU

PP

LYC

ON

NE

CTI

ON

FOR

3P

HA

SE

OP

ER

ATO

RS

ANIN

DE

PE

ND

EN

TS

UP

PLY

INC

LUD

ING

AN

EU

TR

AL

CO

NN

EC

TIO

NM

US

TB

EIN

STA

LLE

D

FOR

1P

HA

SE

OP

ER

ATO

RS

THE

MO

TOR

SU

PP

LYC

AN

BE

SU

PPLI

ED

VIA

ANIN

DE

PE

ND

EN

TS

UP

PLY

OR

TAK

END

IRE

CT

LYFR

OM

TER

MIN

ALS

51(E

),52

,(N

)AN

D53

(L)

RE

D

YEL

LOW

PU

RP

LE

BLA

CK

RED

Mot

orC

ont

rolC

able

24v

d.c

.Sol

enoi

dC

able

230v

Sol

eno

idR

eset

Cab

le

BR

AK

ER

ELE

AS

ESO

LEN

OID

'JM

'SE

RIE

SO

PE

RA

TOR

230V

MA

INS

SU

PP

LY

(Ke

y-s

wit

ch

sho

wn

-S

AP

Z1-

2T)

2 1PP

GE

NE

RA

LC

ON

NE

CTI

ON

FO

R'J

M'S

ER

IES

FIR

ES

HU

TT

ER

OP

ER

ATO

RS

(2S

TAG

EC

LOS

ING

-FA

ST

SE

T5)

(Pu

sh

Bu

tto

nS

tatio

nE

LS

3N

Su

pp

lie

dw

ith

'JM

'op

erat

or)

2nd

STA

GE

CLO

SIN

GS

ELE

CTA

BLE

FIR

EA

LAR

MS

IGN

AL

(N/O

VO

LTF

RE

EC

ON

TA

CT

SH

OW

N)

Not

e:1s

tST

AG

ES

IGN

ALIS

USU

ALLY

TR

IPP

EDV

IAT

HE

MAI

NF

IRE

ALA

RM

2nd

ST

AG

EIS

US

UA

LLY

TRIP

PE

DV

IAA

LOC

AL

SM

OK

EO

RH

EA

TD

ETE

CT

OR

IFO

NLY

1S

IGN

ALIS

US

ED

,FIT

SIG

NA

LIN

"ZO

NE

2"

ON

LY

Page 7: FCP03 CONNECTION TO ellard...• Panel will now show "Engineers set up fast set 1 press the "up" button until the display shows "fast set 5" then press "select" • Display will now

7(Ke

y-s

wit

ch

sho

wn

-S

AP

Z1-

2T)

2 1PP

FIT

LIN

KH

ER

E(C

AU

TIO

NM

AIN

SVO

LTA

GE

PR

ESE

NT

)

BR

OW

N

BLA

CK

GR

N/Y

ELTO

TER

M51

(E)

BLU

ETO

TER

M52

(N) NO

TE

:F

US

E'F

4'M

US

TB

EC

HA

NG

ED

TO

SU

ITT

HE

LO

AD

ING

OF

TH

EM

OT

OR

SE

LE

CT

ED

TH

EP

AN

EL

RE

QU

IRE

SP

RO

GR

AM

MIN

GF

OR

'FA

ST

SE

T4'

(SE

E'F

AS

TS

ET

PR

OG

RA

MM

ING

INS

TR

UC

TIO

N')

SE

LEC

TAB

LEFI

RE

ALA

RM

SIG

NA

L(N

/OV

OLT

FR

EE

CO

NT

AC

TS

HO

WN

)

230V

MA

INS

SU

PP

LY

N/O

N/O

((P

ush

Bu

tto

nS

tati

on

KD

T3

N)

GE

NE

RA

LC

ON

NE

CTI

ON

FO

RT

UB

EM

OTO

RS

(DR

IVE

DO

WN

CLO

SIN

G-

FAS

TS

ET

4)

Page 8: FCP03 CONNECTION TO ellard...• Panel will now show "Engineers set up fast set 1 press the "up" button until the display shows "fast set 5" then press "select" • Display will now

8 (Ke

y-s

wit

ch

sho

wn

-S

AP

Z1-

2T)

2 1PP

FIT

LIN

KH

ER

E(C

AU

TIO

NM

AIN

SVO

LTA

GE

PRES

EN

T)

BR

OW

N

BLA

CK

GR

N/Y

ELTO

TER

M51

(E)

BLU

ETO

TER

M52

(N) NO

TE

:F

US

E'F

4'M

US

TB

EC

HA

NG

ED

TO

SU

ITT

HE

LO

AD

ING

OF

TH

EM

OT

OR

SE

LE

CT

ED

TH

EP

AN

EL

RE

QU

IRE

SP

RO

GR

AM

MIN

GF

OR

'FA

ST

SE

T4'

(SE

E'F

AS

TS

ET

PR

OG

RA

MM

ING

INS

TR

UC

TIO

N')

230V

MA

INS

SU

PP

LY

N/O

N/O

((P

ush

Bu

tto

nS

tati

on

KD

T3

N)

GE

NE

RA

LC

ON

NE

CTI

ON

FO

RT

UB

EM

OTO

RS

(2S

TAG

EC

LOS

ING

-FA

ST

SE

T5)

Not

e:1s

tST

AG

ES

IGN

AL

ISU

SUAL

LYT

RIP

PE

DV

IAT

HE

MA

INFI

RE

ALA

RM

2nd

ST

AG

EIS

US

UA

LLY

TRIP

PE

DV

IAA

LOC

AL

SM

OK

EO

RH

EA

TD

ETE

CTO

R

IFO

NLY

1S

IGN

AL

ISU

SE

D,F

ITS

IGN

AL

IN"Z

ON

E2

"O

NLY

2nd

STA

GE

CLO

SIN

GS

ELE

CT

ABLE

FIR

EA

LAR

MSI

GN

AL

(N/O

VO

LTF

RE

EC

ON

TA

CT

SH

OW

N)

1stS

TAG

EC

LOS

ING

SE

LEC

TAB

LEFI

RE

ALA

RM

SIG

NA

L(N

/OV

OLT

FR

EE

CO

NT

AC

TS

HO

WN

)

Page 9: FCP03 CONNECTION TO ellard...• Panel will now show "Engineers set up fast set 1 press the "up" button until the display shows "fast set 5" then press "select" • Display will now

9

Page 10: FCP03 CONNECTION TO ellard...• Panel will now show "Engineers set up fast set 1 press the "up" button until the display shows "fast set 5" then press "select" • Display will now

10 5

LO

CA

LA

CT

IVA

TIO

NM

AIN

FIR

EA

LAR

MS

IGN

AL

TO

BE

FIT

TE

DTO

ZON

E1

MA

INA

CT

IVA

TIO

NN

OO

TH

ER

FIR

EA

LAR

MS

IGN

AL

TOB

EFI

TTE

DT

OZ

ON

E1

MA

INA

CT

IVA

TIO

NF

AS

TS

ET

1(S

OLE

NO

IDD

RO

P)

FA

ST

SE

T4

(DR

IVE

DO

WN

)

R

L1OU

T

EA

RT

H

L1IN

N/O

COM

N/C

L2

EA

RTH

CO

M

L1IN

L1O

UT

N/O

R

L2

N/C

EA

RTH

CO

M

L1IN

L1O

UT

N/O

R

L2

N/C

MA

INA

CT

IVA

TIO

NF

AS

TS

ET

5(2

STA

GE

CL

OS

ING

)P

RIM

AR

YF

IRE

SIG

NA

L

LO

CA

LA

CTI

VA

TIO

NF

AS

TS

ET

5(2

STA

GE

CL

OS

ING

)S

EC

ON

DA

RY

FIR

ES

IGN

AL

Page 11: FCP03 CONNECTION TO ellard...• Panel will now show "Engineers set up fast set 1 press the "up" button until the display shows "fast set 5" then press "select" • Display will now

11

EAR

TH

N/O

L1OUT

L1IN

L2

N/C

CO

M

R

L1IN

L2

L1OUT

EAR

TH

N/O

CO

MN

/C

R

GE

NE

RA

LC

ON

NE

CT

ION

FOR

MU

LTIP

LES

MO

KE

/HE

AT

DE

TEC

TO

RU

NIT

S

Page 12: FCP03 CONNECTION TO ellard...• Panel will now show "Engineers set up fast set 1 press the "up" button until the display shows "fast set 5" then press "select" • Display will now

12

ellard LtdRoundthorn Ind Est

Dallimore RoadWythenshawe