IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

2 of 38

IST(02) 029 A4 모(101025)

TABLE OF CONTENTS

Table of contents 2

Information of test laboratory, Power Supply System Used, 3

Measurement Uncertainty, Product Information

Equipment Under Test and test setup 4

Summary 5

Test Conditions and Data - Emissions

Conducted Emissions 0.15 MHz - 30 MHz Applicable

Test Conditions / Data and Plots 6-9

Radiated Emissions 30 MHz - 5000 MHz Applicable

Test Conditions / Data and Plots 10-11

Harmonic Current And Voltage Fluctuations

Harmonic Current Not applicable

Test Conditions / Data and Plots

Voltage Flicker Applicable

Test Conditions / Data and Plots 12-14

Test Conditions and Data - Immunity

Electro-Static Discharge Applicable

Test Conditions / Data and Plots 15-17

Radiated Susceptibility Applicable

Test Conditions / Data and Plots 18-19

Electrical Fast Transient (Burst) Applicable

Test Conditions / Data and Plots 20-21

Surge Transient Applicable

Test Conditions / Data and Plots 22-23

Conducted Susceptibility Applicable

Test Conditions / Data and Plots 24-25

Power Frequency Magnetic Not applicable

Test Conditions / Data and Plots

Voltage Dips, interruptions Applicable

Test Conditions / Data and Plots 26-27

Appendix A. The Test Setup Photos 28-33

B. The Photos of ESD Measurement 34-35

C. The EUT Photos 36-38

Page 3: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

3 of 38

IST(02) 029 A4 모(101025)

INFORMATION OF TEST LABORATORY

IST Co., Ltd.

400-19, Singal-dong, Giheung-gu, Yongin-si,

Kyonggi-Do, 446-599, Korea

TEL : +82 31 326 6700 FAX : +82 31 326 6797 KOLAS Testing No. : 118 RRA Designation No. : KR0018 FCC Registration No. : 400603 FCC(DoC) Registration No. : 801060 VCCI Member No. : 1739

POWER SUPPLY SYSTEM USED

Power supply system AC 230 V, 50 Hz

(Refer to the product information)

Measurement Uncertainty

The measurement uncertainty was evaluated for all test items listed in

this report. Also it, “ The evaluation and treatment of uncertainty “,

is described in IST Quality Manual according to ISO17025 Guide. The data

and results described in this report are true and include evaluated

uncertainty. It may cause some deviation of uncertainty by change component

or process of the test for similar products.

PRODUCT INFORMATION

Video Input 16 Channel Composite

Video Outputs CCTV Monitor(NTSC/PAL), CRT(VGA) Monitor 16 CH Looping Composite, 3 Spot CCTV Monitor(NTSC/PAL)

Monitor Display NTSC : 480 fps, PAL : 400 fps Monitor Screen split 1/4/9/16/PIP Recording Compression H.264 Recording Storage media Internal 2 x HDD(Option), USB Recording Audio 4 Channel, G.726 Compression Camera Control Pan/Tilt, Zoom, Focus, Iris Back-up DVD +/- RW, USB

Power(Adapter) Input : AC(100~240) V, (50~60) Hz, 1.5 A Output : DC12 V, 5.0 A

Size 400mm x 88 mm x 400 mm

-EMC suppression device is not used during the test.

-Find information in user manual.

Page 4: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

4 of 38

IST(02) 029 A4 모(101025)

Equipment Under Test

EUT Type :

Table-Top. Floor-Standing. Table-Top and Floor-Standing (Combination).

Operation – mode of the E.U.T. :

The equipment under test was operated during the measurement under following

conditions :

Standby. Operational Condition : Recording during Network communication(ping) mode

Configuration of the equipment under test :

Following peripheral devices and interface cables were connected during the

measurement :

Equipment Type Brand Serial No. Adapter(EUT) PA-1061-0 LITE-ON TECHNOLOGY CORPORATION N/A LCD Monitor M2294DJ LG Electronics 902KCYQ4R914Notebook PC CP10 Arima Computer NC2CCHS4J1LCAdapter(Notebook) ADP-50HH DELTA KJW0249000842CCD Camera CNB-GN258 CNB CN560241278Adapter(Camera) DSA-04215-12 1 42 Dee Van Electronic Co.,Ltd. 60308032 Mouse(Serial) M-MD14-2 Logitech Inc. N/A USB Memory US01M1 EO Electron N/A Track ball mouse SPR-8695TU SEJIN ELECTRON INC. 7AFZ007772 Connecting Interface Cables :

- Shielded VGA(D-Sub) cable(with two ferrite core): 1.8 m - Shielded VIDEO IN(BNC) cable(without ferrite core): 3.0 m - Shielded VIDEO OUT(BNC) cable(without ferrite core): 3.0 m - Shielded TV/SPOT OUT(BNC) cable(without ferrite core): 3.0 m - Unshielded RS485 cable(without ferrite core): 5.0 m - Unshielded SENSOR/ALARM cable(without ferrite core): 3.0 m - Unshielded LAN(RJ-45) cable(without ferrite core): 3.0 m - Unshielded Mouse’s RS-232 cable(without ferrite core): 1.6 m - Unshielded Track ball mouse USB cable(without ferrite core): 1.0 m

The drawing of general test setup :

Page 5: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

5 of 38

IST(02) 029 A4 모(101025)

SUMMARY

Emissions

Conducted Emissions

The requirements are MET Not MET

Minimum limit margin 3.25 dB at 23.130 MHz

Maximum limit exceeding

Remarks : Limits are kept with more than 3 dB margin

Radiated Emissions

The requirements are MET Not MET

Minimum limit margin 3.54 dB at 126.03 MHz

Maximum limit exceeding

Remarks : Limits are kept with more than 3 dB margin

Generic Test

Harmonic Current/Voltage Flicker

The requirements are MET Not MET

Immunity

Electrostatic Discharge MET Not MET

Radiated Electromagnetic Fields MET Not MET

Electrical Fast Transient (Burst) MET Not MET

Surge Transient MET Not MET

Conducted Susceptibility MET Not MET

Power Frequency Magnetic MET Not MET

Voltage Dips, interruption MET Not MET

Page 6: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

6 of 38

IST(02) 029 A4 모(101025)

TEST CONDITIONS AND DATA

Conducted Emissions

[Applicable]

Test Equipment Used

The test equipment used is calibrated in regular for every year.

Model Name Description Manufacture Due Calibration Serial No.

ESCI Test Receiver Rohde & Schwarz May 21, 2011 100374

ESH2-Z5 LISN Rohde & Schwarz May 21, 2011 842966/007

ESH3-Z2 Pulse Limiter Rohde & Schwarz May 21, 2011 357.8810.52

ISN T800 ISN TESEQ May 21, 2011 26107

Environmental Conditions

Temperature (18.5 ± 0.2)

Humidity (38 ± 0.1) % R.H.

Atmosphere pressure 1011 hPa

Test Program See the operation mode on page 4.

Test Area Conducted Room #2

Test Date May 02, 2011

Note :

Page 7: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

7 of 38

IST(02) 029 A4 모(101025)

Conducted Emissions Live

Freq. [MHz]

Measurement [dB]

Limit [dB]

InsertionLoss

CableLoss

Result [dB]

Margin [dB]

Q-peak Average Q-peak Average [dB] [dBuV] Q-peak Average Q-peak Average

0.150 44.48 30.40 66.00 56.00 0.15 0.01 44.64 30.56 21.36 25.44

0.186 41.01 24.30 64.21 54.21 0.14 0.01 41.16 24.45 23.05 29.76

0.214 36.12 18.74 63.05 53.05 0.14 0.01 36.27 18.89 26.78 34.16

0.610 29.11 18.54 56.00 46.00 0.17 0.02 29.30 18.73 26.70 27.27

1.098 34.30 22.54 56.00 46.00 0.19 0.04 34.53 22.77 21.47 23.23

24.214 35.56 34.03 60.00 50.00 1.05 0.20 36.81 35.28 23.19 14.72

Note :

Page 8: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

8 of 38

IST(02) 029 A4 모(101025)

Conducted Emissions Neutral

Freq. [MHz]

Measurement [dB]

Limit [dB]

InsertionLoss

CableLoss

Result [dB]

Margin [dB]

Q-peak Average Q-peak Average [dB] [dBuV] Q-peak Average Q-peak Average

0.150 43.89 30.71 66.00 56.00 0.15 0.01 44.05 30.87 21.95 25.13

0.182 41.74 24.69 64.39 54.39 0.15 0.01 41.90 24.85 22.49 29.54

0.210 38.85 21.28 63.21 53.21 0.15 0.01 39.01 21.44 24.19 31.76

0.626 33.31 24.26 56.00 46.00 0.18 0.02 33.51 24.46 22.49 21.54

1.114 32.05 19.51 56.00 46.00 0.21 0.04 32.30 19.76 23.70 26.24

24.214 34.98 33.35 60.00 50.00 0.88 0.20 36.06 34.43 23.94 15.57

Note :

Page 9: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

9 of 38

IST(02) 029 A4 모(101025)

Conducted Emissions

Freq. [MHz]

Measurement [dB]

Limit [dB]

InsertionLoss

CableLoss

Result [dB]

Margin [dB]

Q-peak Average Q-peak Average [dB] [dB] Q-peak Average Q-peak Average

5.238 44.51 41.32 74.00 64.00 9.67 0.09 54.27 51.08 19.73 12.92

7.926 49.71 46.50 74.00 64.00 9.59 0.11 59.41 56.20 14.59 7.80

13.358 53.56 49.80 74.00 64.00 9.67 0.14 63.38 59.62 10.62 4.38

17.694 54.76 49.90 74.00 64.00 9.81 0.17 64.74 59.88 9.26 4.12

23.130 58.00 50.50 74.00 64.00 10.05 0.20 68.25 60.75 5.75 3.25

Note : Telecommunication ports

Page 10: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

10 of 38

IST(02) 029 A4 모(101025)

TEST CONDITIONS AND DATA

Radiated Emissions

[Applicable]

Test Equipment Used

The test equipment used is calibrated in regular for every year.

Model Name Description Manufacture Due Calibration Serial No.

ESCS30 Test Receiver Rohde & Schwarz Sep. 17, 2011 100171

VULB 9160 Antenna Schwarzbeck Aug. 06, 2011 3048

E7405A Spectrum Analyzer Schwarzbeck Sep. 17, 2011 US41160290

BBHA 9120D Horn Antenna H.P. Jun. 11, 2012 9120D-826

8348A Preamplifier Max-Full Antenna Corp

Sep. 16, 2011 3307A02865

MFT-120S Turn-Table AFS42-01001800-28-10P-42 N/A -

MITEQ Inc. Amplifier Schwarzbeck Feb. 14, 2012 1565819

Environmental Conditions

Temperature (14.4 ± 0.5)

Humidity (37 ± 0.8) % R.H.

Atmosphere pressure 1013 hPa

Test Program See the operation mode on page 4.

Test Area Open Test Site #2 (10 m)

Full-Anechoic Room (3 m) (ETL LABORATORY)

Test Date May 3, 2011

Note :

Page 11: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

11 of 38

IST(02) 029 A4 모(101025)

Radiated Emissions

(Disturbance Radiation)

Freq. [MHz]

Reading [dBuV]

AntennaFactor[dB/m]

CableLoss [dB]

Polar.[H/V]

Limit [dBuV/m]

Result [dBuV/m]

Margin [dB]

30.970 11.50 12.03 0.96 V 30.00 24.49 5.51

37.760 12.30 12.22 1.05 V 30.00 25.57 4.43

63.950 11.50 11.17 1.32 V 30.00 23.99 6.01

126.030 13.00 11.62 1.84 V 30.00 26.46 3.54

150.280 11.20 12.62 1.99 V 30.00 25.81 4.19

175.500 11.10 11.45 2.16 V 30.00 24.71 5.29

500.451 11.00 17.46 3.82 H 37.00 32.28 4.72

750.703 5.50 21.60 4.59 V 37.00 31.69 5.31

Note :

Radiated Emissions

(Disturbance Radiation)

Freq. [MHz]

Reading [dBuV]

c.f [dB(1/m)]

Polar.[H/V]

Limit [dBuV/m]

Result [dBuV/m]

Margin [dB]

Peak Detector

1076.76 43.60 -3.30 H 70.00 46.90 23.10

1125.24 43.50 -3.30 V 70.00 40.20 29.80

1500.96 52.00 -2.50 V 70.00 49.50 20.50

1864.56 42.90 -2.00 V 70.00 40.90 29.10

2123.21 43.70 -0.20 V 70.00 43.50 26.50

Average Detector

1076.76 38.40 -3.30 H 50.00 41.70 8.30

1125.24 36.50 -3.30 V 50.00 33.20 16.80

1500.96 39.80 -2.50 V 50.00 37.30 12.70

1864.56 37.00 -2.00 V 50.00 35.00 15.00

2123.21 36.90 -0.20 V 50.00 36.70 13.30

Note : Limits above 1 GHz(3 m method)

Page 12: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

12 of 38

IST(02) 029 A4 모(101025)

TEST CONDITIONS AND DATA

Harmonic Current/Voltage Flicker

[Applicable]

Test Equipment Used

The test equipment used is calibrated in regular for every year.

Model Name Description Manufacturer Due Calibration Serial No.

PM6000 Power Analyzer Voltech Jan. 31, 2012 100006700213

IEC Standard 555 Impedance Network Voltech Jan. 28, 2012 1B0318251

4500L AC Power Source California May 21, 2011 HK51408

Environmental Conditions

Temperature (22 ± 0.2)

Humidity (39 ± 0.1) % R.H.

Atmosphere pressure 1013 hPa

Test Program See the operation mode on page 4.

Test Area EMI Test Room

Test Date May 4, 2011

Note : Harmonic test is omitted because rated power is less than 75 watts.

(See clause 7 of EN61000-3-2)

Page 13: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

13 of 38

IST(02) 029 A4 모(101025)

Note :

Page 14: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

14 of 38

IST(02) 029 A4 모(101025)

Note :

Page 15: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

15 of 38

IST(02) 029 A4 모(101025)

TEST CONDITIONS AND DATA

Electrostatic Discharge

[Applicable]

Test Equipment Used

The test equipment used is calibrated in regular for every year.

Model Name Description Manufacture Due Calibration Serial No.

ESS-2000 ESD Simulator NoiseKen Jul. 18, 2011 ESS0442747

TC-815P ESD Tip NoiseKen Jul. 18, 2011 ESS0442694

Environmental Conditions

Temperature (21.5 ± 0.2)

Humidity (37.4 ± 0.1) % R.H.

Atmosphere pressure 1011 hPa

Test Program See the operation mode on page 4.

Test Area EMS Test Room

Test Date May 6, 2011

Note :

Page 16: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

16 of 38

IST(02) 029 A4 모(101025)

Electrostatic Discharge(ESD)

[Applicable]

Test Specification:

Discharge Voltage (Air): 2 kV 6 kV 15 kV

4 kV 8 kV kV

Discharge Voltage : 2 kV 6 kV kV

(Contact) 4 kV 8 kV

Discharge Impedance: 330 Ω / 150 pF 150 Ω / 150 pF

Discharge Repetition Rate : 1 s

Number of Discharges: 10 times at all locations (Air discharge)

10 times at all locations (Contact discharge)

Kind of Discharges: Air discharge Contact discharge

Direct Indirect (HCP/VCP)

Polarity: Positive Negative

Location of Discharge: Each location on the surface accessible by hand

See drawing in page 33-34

Result :

No degradation of function Met Criterion A

Distortion of function Met Criterion B

Error of function Met Criterion C

Loss of function Unrecoverable Failure

Note: During the performed test there was no change of operation mode.

Page 17: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

17 of 38

IST(02) 029 A4 모(101025)

Electrostatic Discharge (ESD)

List of ESD Points Discharge

Voltage(V) Test Point

Test Result(s)

±2 kV ±4 kV ±6 kV ±8 kV

HCP(C) A A A -

VCP(C) A A A -

Front CD-ROM(A) A A - A

Front Surface(C) A A A -

Upper Surface(C) A A A -

Rear Surface/Screw/Ports(C) A A A -

Side Surface/Screw(C) A A A -

(A): Air Discharge (C): Contact Discharge

Note :

Page 18: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

18 of 38

IST(02) 029 A4 모(101025)

TEST CONDITIONS AND DATA

Radiated Susceptibility

[Applicable]

Test Equipment Used

The test equipment used is calibrated in regular for every year.

Model Name Description Manufacture Due Calibration Serial No.

SML03 Signal Generator Rohde & Schwarz May 21, 2011 102212

NRVD Power Meter Rohde & Schwarz May 21, 2011 101242

NRV-Z51 Power Sensor Rohde & Schwarz May 21, 2011 100330

NRV-Z51 Power Sensor Rohde & Schwarz May 21, 2011 100331

HI-6005 Field sensor ETS Aug. 08, 2011 00052474

AR200W Amplifier Amplifier Research - 14124

LPDA-0803 Log-periodic Ant. TDK RF - 130232

AT4002A Microwave Horn Ant. TDK RF - 312314

Environmental Conditions

Temperature (20 ± 0.2)

Humidity (40 ± 0.1) % R.H.

Atmosphere pressure 1013 hPa

Test Program See the operation mode on page 4.

Test Area Full anechoic chamber

Test Date May 8, 2011

Note :

Page 19: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

19 of 38

IST(02) 029 A4 모(101025)

Radiated Susceptibility

[Applicable]

Test Specification

Frequency Range: 27 MHz – 500 MHz 900 MHz

9 kHz - 27 MHz 80 MHz – 2000 MHz

Field Strength: 1 V/m 3 V/m

10 V/m V/m

Distance Antenna – EUT: 1 m 3 m

Modulation: AM : 80 %

FM : kHz dev.

Sine wave: 1 kHz

Unmodulated

Pulse : 1 Hz

Duty Cycle: 50 %

Step: < 0.0015 decades/s

1 % / 3 s log 1 % / 3 s

Polarization of Antenna: Horizontal Vertical

Position Front Left

Right Rear

Result

No degradation of function Met Criterion A

Distortion of function Met Criterion B

Error of function Met Criterion C

Loss of function Unrecoverable Failure

Note : During the performed test there was no change of operation mode.

Page 20: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

20 of 38

IST(02) 029 A4 모(101025)

TEST CONDITIONS AND DATA

Electrical Fast Transient

[Applicable]

Test Equipment Used

The test equipment used is calibrated in regular for every year.

Model Name Description Manufacture Due Calibration Serial No.

PHV41.2 Burst Generator Heafely May 21, 2011 083057-18

IP4A Capacitive Clamp Heafely May 21, 2011 083-078-32

Environmental Conditions

Temperature (21.5 ± 0.2)

Humidity (37.4 ± 0.1) % R.H.

Atmosphere pressure 1011 hPa

Test Program See the operation mode on page 4.

Test Area EMS Test Room

Test Date May 6, 2011

Note :

Page 21: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

21 of 38

IST(02) 029 A4 모(101025)

Electrical Fast Transient (Burst)

[Applicable]

Test Specification

Pulse Amplitude - AC Power Port: 0.5 kV 1.0 kV

2.0 kV

Pulse Amplitude - DC Power Port: 1.0 kV 2.0 kV

4.0 kV

Pulse Amplitude - Signal/Data 0.5 kV 1.0 kV

Non control Port: 2.0 kV 0.25 kV

Pulse Amplitude - Process: 0.5 kV 1.0 kV

Measurement & Control Port 2.0 kV

Burst Frequency: 2.5 kHz 5.0 kHz

Duration per application : 1 (+0.2/-0) (min)

Time of Coupling: 60 s 120 s

Coupling Method: Coupling/decoupling network Coupling clamp

Polarity: Positive Negative

Location of Coupling:

name of lines: AC Power cable(Adapter) length : 0.5 m

type of lines shielded unshielded

status of lines: passive active

kind of transmission: analog digital

name of lines: BNC(VIDEO IN, VIDEO/TV/SPOT OUT) cable length : 3.0 m

type of lines shielded unshielded

status of lines: passive active

kind of transmission: analog digital

name of lines: LAN, RS485, SENSOR/ALARM cable length : 5.0 m

type of lines shielded unshielded

status of lines: passive active

kind of transmission: analog digital

Result :

No degradation of function Met Criterion A

Distortion of function Met Criterion B

Error of function Met Criterion C

Loss of function Unrecoverable Failure

Note: Color camera’s input picture was flickerd during the test, but it was

recovered by itself after test.

Page 22: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

22 of 38

IST(02) 029 A4 모(101025)

TEST CONDITIONS AND DATA

Surge Transient

[Applicable]

Test Equipment Used

The test equipment used is calibrated in regular for every year.

Model Name Description Manufacture Due Calibration Serial No.

PSURGE 4.1 Surge Generator Heafely May 21, 2011 082876-05

IP6.2 COUPLING NETWORK Heafely - 082876-02

Environmental Conditions

Temperature (21.1 ± 0.2)

Humidity (38.5 ± 0.1) % R.H.

Atmosphere pressure 1012 hPa

Test Program See the operation mode on page 4.

Test Area EMS Test Room

Test Date May 7, 2011

Note :

Page 23: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

23 of 38

IST(02) 029 A4 모(101025)

Surge Transient

[Applicable]

Test Specification

Pulse amplitude

– Power line :

0.5 kV 1.0 kV : Line to line

0.5 kV 1.0 kV 2.0 kV : Line to ground

Pulse amplitude

– Signal line :

0.5 kV

2.0 kV

1.0 kV

Source impedance : 18 µF : Line to line

Via a 40 series resistor 10 + 9 µF: Line to ground

Number of surges : 3 surges/angle 20 surges/polarity

Angle 0° 90°

180° 270°

Repetition rate : 10 s 60 s

Polarity : Positive Negative

Location of Coupling:

name of lines: AC Power cable(Adapter) length : 1.0 m

type of lines shielded unshielded

status of lines: passive active

kind of transmission: analog digital

name of lines: BNC(VIDEO IN) cable length : 30.0 m

type of lines shielded unshielded

status of lines: passive active

kind of transmission: analog digital

name of lines: RS485(TX +/-) cable length : 30.0 m

type of lines shielded unshielded

status of lines: passive active

kind of transmission: analog digital

Result :

No degradation of function Met Criterion A

Distortion of function Met Criterion B

Error of function Met Criterion C

Loss of function Unrecoverable Failure

Note : During the performed test there was no change of operation mode.

Page 24: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

24 of 38

IST(02) 029 A4 모(101025)

TEST CONDITIONS AND DATA

Conducted Susceptibility

[Applicable]

Test Equipment Used

The test equipment used is calibrated in regular for every year.

Model Name Description Manufacture Due Calibration Serial No.

SMT 02 Signal Generator Rohde & Schwarz Oct. 12, 2011 833414/019

250LM1 Amplifier Amplifier Research - 14229

URV5 AC Milivoltmeter Rohde & Schwarz Oct. 12, 2011 836671/003

URV-Z2 INSERTION UNIT 50 Rohde & Schwarz Oct. 13, 2011 DE105101

URV-Z2 INSERTION UNIT 50 Rohde & Schwarz Oct. 13, 2011 DE105102

50FH-006-50 Attenuator JFW May 21, 2011 -

FCC-150-50 (50-150) Adapter FCC May 21, 2011 05039

FCC-150-50 (50-150) Adapter FCC May 21, 2011 05040

FCC-801-M3-50 CDN FCC Aug. 18, 2011 28

FCC-203I EM Clamp FCC Jan. 31, 2012 2

FCC-205ADC Decoupling Clamp FCC Jan. 31, 2012 1

Environmental Conditions

Temperature (22 ± 0.2)

Humidity (38 ± 0.1) % R.H.

Atmosphere pressure 1012 hPa

Test Program See the operation mode on page 4.

Test Area Full anechoic chamber

Test Date May 9, 2011

Note :

Page 25: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

25 of 38

IST(02) 029 A4 모(101025)

Conducted Susceptibility

[Applicable]

Test Specification

Frequency – range : 0.01 MHz – 150 MHz 80 MHZ – 230 MHz

0.15 MHz – 100 MHz

Voltage level (EMF) : 1 V 10 V

3 V

Modulation : AM: 80 %, 1 kHz, sinusoidal Pulse: 1 Hz(0.5 s ON : 0.5 s OFF)

FM : Unmodulated

Frequency step : 0.015 oct/s Log 1 %

Dwell Time : 3 s 2 s 1 s

Location of Coupling:

name of lines: AC Power cable(Adapter) length : 0.3 m

type of lines shielded unshielded

status of lines: passive active

kind of transmission: analog digital

name of lines: BNC(VIDEO IN, VIDEO/TV/SPOT OUT) cable length : 3.0 m

type of lines shielded unshielded

status of lines: passive active

kind of transmission: analog digital

name of lines: LAN, RS485, SENSOR/ALARM cable length : 5.0 m

type of lines shielded unshielded

status of lines: passive active

kind of transmission: analog digital

Result :

No degradation of function Met Criterion A (1 V, 3 V)

Distortion of function Met Criterion B (10 V)

Error of function Met Criterion C

Loss of function Unrecoverable Failure

Note : For power line test, color camera’s input picture was flickerd at voltage

level 10 V, but the EUT operated as normal after the test.

For voltage level 1 V and 3 V test, the EUT operated normally.

Page 26: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

26 of 38

IST(02) 029 A4 모(101025)

TEST CONDITIONS AND DATA

Voltage Dips, Interruptions

[Applicable]

Test Equipment Used

The test equipment used is calibrated in regular for every year.

Model Name Description Manufacture Due Calibration Serial No.

PLINE 1610 Dips Generator Haefely May 21, 2011 083690-19

Environmental Conditions

Temperature (21.1 ± 0.2)

Humidity (38.5 ± 0.1) % R.H.

Atmosphere pressure 1012 hPa

Test Program See the operation mode on page 4.

Test Area EMS Test Room

Test Date May 7, 2011

Note :

Page 27: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

27 of 38

IST(02) 029 A4 모(101025)

Dips/Interruptions

[Applicable]

Test Specification

Normal Voltage/frequency: 100 Vac/50 Hz 230 Vac/50 Hz

Duration of reduction: 0.5 P 1 P 5 P 10 P

(Voltage reduction 30 %)

Duration of reduction: 0.5 P 1 P 5 P 10 P

(Voltage reduction 60 %)

Duration of reduction: 0.5 P 1 P 5 P

(Voltage reduction 100 %)

Number of reductions at each duration : 3

Interval between reductions : 10 s

Phase: 0˚ 45˚ 90˚ 135˚

180˚ 225˚ 270˚ 315˚

Result : 100 Vac/50 Hz

Test Dips(30 %) Dips(60 %) Dips(100 %)

Variation (Unom -15 %)

0.5/1/5/10 period

0.5/1/5/10 period

0.5/1/5 period

Criteria A A A A B B B B C C C C

Result : 230 Vac/50 Hz

Test Dips(30 %) Dips(60 %) Dips(100 %)

Variation (Unom +10 %)

0.5/1/5/10 period

0.5/1/5/10 period

0.5/1/5 period

Criteria A A A A B B B B C C C C

Note: During the performed test there was no change of operation mode.

Page 28: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

28 of 38

IST(02) 029 A4 모(101025)

Appendix A. Test Setup Photos

Conducted Emissions

Conducted Emissions at telecommunication ports

Page 29: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

29 of 38

IST(02) 029 A4 모(101025)

Appendix A. Test Setup Photos

Radiated Emissions – Front View

Radiated Emissions – Rear View

Page 30: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

30 of 38

IST(02) 029 A4 모(101025)

Appendix A. Test Setup Photos

Radiated Emissions above 1 GHz

H&F

Page 31: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

31 of 38

IST(02) 029 A4 모(101025)

Appendix A. Test Setup Photos

Electro-Static Discharge

Radiated Susceptibility

Page 32: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

32 of 38

IST(02) 029 A4 모(101025)

Appendix A. Test Setup Photos

Electrical Fast Transient

Surge Transient

Page 33: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

33 of 38

IST(02) 029 A4 모(101025)

Appendix A. Test Setup Photos

Conducted Susceptibility

Voltage Dips

Page 34: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

34 of 38

IST(02) 029 A4 모(101025)

Discharge (Air)

Appendix B. The Photos of ESD Measurement Discharge (Contact)

ESD Point

C

A

C

Page 35: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

35 of 38

IST(02) 029 A4 모(101025)

Discharge (Air)

Appendix B. The Photos of ESD Measurement Discharge (Contact)

ESD Point

C

C

Page 36: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

36 of 38

IST(02) 029 A4 모(101025)

Appendix C. The EUT Photos

Front View

Rear View

Page 37: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

37 of 38

IST(02) 029 A4 모(101025)

Appendix C. The EUT Photos

Inner View

Page 38: FCC(DoC) Registration No. : 801060webhard.win4net.com/file_server/pub/00_Sales/PCO/11-IST-0272... · TEST REPORT NO. : 11-IST-0272 2 of 38 IST(02) 029 A4 모(101025) TABLE OF CONTENTS

IST Co., Ltd. TEST REPORT NO. : 11-IST-0272

38 of 38

IST(02) 029 A4 모(101025)

Appendix C. The EUT Photos

Adapter View

Adapter label View