2
www.ecolibriumsolar.com [email protected] US: 740-249-1877 The EcoMount Inverter Kit is an innovative, ballasted rooftop inverter mounting solution, designed to simplify and streamline rooftop inverter deployment. The modular design provides flexibility, simplifies logistics, and simplifies the installation. Fast. EcoMount is built upon the EcoFoot2+ mounting system platform, the fastest installing system on the market, as validated by DNV GL. Simple. With a single socket size, pre- packaged kits, and a wide range of compatible inverters, EcoMount is quick and easy to deploy. Supported. The Ecolibrium engineering and field support teams are ready to provide training and technical support. ® 7-12-15 EcoMount Flyer.indd 1 9/10/2015 1:21:37 PM

Fast. Simple. Supported. · 2015. 9. 16. · 2 eco-002_805 insert, 3 slot, ecomount kit, 1 inverter 2 3 ECO-002_922 PACKAGING, ECOMOUNT HARDWARE KIT, 1 INVERTER 1 4 ECO-002_921 PACKAGING,

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Fast. Simple. Supported. · 2015. 9. 16. · 2 eco-002_805 insert, 3 slot, ecomount kit, 1 inverter 2 3 ECO-002_922 PACKAGING, ECOMOUNT HARDWARE KIT, 1 INVERTER 1 4 ECO-002_921 PACKAGING,

[email protected] US: 740-249-1877

The EcoMount Inverter Kit is an innovative, ballasted rooftop inverter mounting solution, designed to simplify and streamline rooftop inverter deployment. The modular design provides � exibility, simpli� es logistics, and simpli� es the installation.

Fast.EcoMount is built upon the EcoFoot2+ mounting system platform, the fastest installing system on the market, as validated by DNV GL.

Simple.With a single socket size, pre-packaged kits, and a wide range of compatible inverters, EcoMount is quick and easy to deploy.

Supported.The Ecolibrium engineering and fi eld support teams are ready to provide training and technical support.

®

7-12-15 EcoMount Flyer.indd 1 9/10/2015 1:21:37 PM

Page 2: Fast. Simple. Supported. · 2015. 9. 16. · 2 eco-002_805 insert, 3 slot, ecomount kit, 1 inverter 2 3 ECO-002_922 PACKAGING, ECOMOUNT HARDWARE KIT, 1 INVERTER 1 4 ECO-002_921 PACKAGING,

[email protected] US: 740-249-1877

Compact DesignThe EcoMount design minimizes the inverter rooftop footprint, allowing installers to meet NEC 690.12 rapid shutdown requirements while not compromising on module density.

Flexible DeploymentThe 1 and 2 inverter kits may be combined to meet all project confi gurations. EcoMount is compatible with all major inverter brands. Up to 5 standard (4”x8”x16”) ballast blocks may be placed on each Base to meet even the most demanding conditions.

Simplifi ed LogisticsEach EcoMount Kit is provided in individual boxes. Allowing for small package delivery for small orders and freight delivery for larger orders. Kits are easily deployed to their rooftop location.

Technical Specifi cations

Materials 757G Luran S ASA; 6063 T6 Aluminum; G90 Steel; Stainless Steel

Dimensions (Assembled) 1 Inverter Kit: 26.6" (L) x 41" (W) x 18" (H)2 Inverter Kit: 26.6" (L) x 82" (W) x 18" (H)

Weight (EcoMount) 1 Inverter Kit: ~27lbs.2 Inverter Kit: ~40lbs.

Inverter Mounting Angle 15°

Inverter Leading Edge Height > 8"

Compatible Inverters ABB Solar; Chint Power Systems; Fronius; SMA; Solectria

Warranty 15 Years

¯

®2

4

5

6

7

1

3

REVISIONSREV. DESCRIPTION DATE APPROVED

A RELEASED FOR PRODUCTION 5/22/2015 BQ

ITEM NO. PART NUMBER DESCRIPTION QTY.1 ECO-002_512 BOLT, SERR FLNG HEX, 3/8-16 UNC-2A X 1" 122 ECO-002_511 NUT, STRUT, 3/8-16 UNC-2B 8

3 ECO-002_515 STRUT, SLOTTED HOLE, 26" 4

4 ECO-002_514 NUT, SERR FLNG HEX, 3/8-16 UNC-2B 45 ECO-002_900 STANDOFF, ECOMOUNT 4

6 ECO-002_310 PIN, CLEVIS 4

7 ECO-002_201 BASE 2

D

C

B

A

A

B

C

D

12345678

8 7 6 5 4 3 2 1

THIRD ANGLE PROJECTION

REVISION:

ECOMOUNT, KIT, 1 INVERTERASM

ASM ASMCOLOR

PART MASS(lbs)

26.3291:50

9/9/2015

ECO-002_901

SHEET 1 OF 1

.00 0.03 INCHES.000 0.015 INCHESANGLES 2

UNLESS OTHERWISE SPECIFIED:DRAWING BASED ON ANSI Y 14.5 SURFACE FINISH 125 ON MACHINED SURFACES. DIMENSIONS SYMMETRICAL ABOUT CENTER LINE WHERE APPLICABLE. ON PLATED PARTS DIMENSIONAL LIMITS APPLY AFTER PLATING. DIMENSIONS OF MOLDED PARTS ARE FOR FINISHED PART. NO ALLOWANCE HAS BEEN MADE FOR SHRINK.

DO NOT SCALE DRAWINGALL DIMENSIONS IN INCHES.REMOVE ALL BURRS.BREAK ALL SHARP EDGES.

TOLERANCES UNLESSOTHERWISE SPECIFIED

DMacRostiePART NUMBER:

APPROVED BY:CHECKED BY:DRAWN BY:

PART NAME

SCALE:

DATE

340 West State St, Unit 22, Athens OH 45701Ecolibrium Solar,Inc. A

FINISH:

SHEET SIZEB

BQuirke CParsons

MATERIAL:

REVISIONSREV. DESCRIPTION DATE APPROVED

A RELEASED FOR PRODUCTION 5/27/2015 BQ

ITEM NO. PART NUMBER DESCRIPTION QTY.1 ECO-002_804 INSERT, 2 SLOT, ECOMOUNT KIT, 1 INVERTER 32 ECO-002_805 INSERT, 3 SLOT, ECOMOUNT KIT, 1 INVERTER 23 ECO-002_922 PACKAGING, ECOMOUNT HARDWARE KIT, 1 INVERTER 14 ECO-002_921 PACKAGING, ECOMOUNT STRUT KIT, 1 INVERTER 15 ECO-002_201 ECOFOOT 2+ BASE 26 ECO-002_801 BOX, ECOMOUNT KIT, 1 INVERTER 1

D

C

B

A

A

B

C

D

12345678

8 7 6 5 4 3 2 1

THIRD ANGLE PROJECTION

REVISION:

PACKAGING, ECOMOUNT, 1 INVERTERASM

ASM ASMCOLOR

PART MASS(lbs)

27.001:50

9/9/2015

ECO-002_911

SHEET 1 OF 1

.00 0.03 INCHES.000 0.015 INCHESANGLES 2

UNLESS OTHERWISE SPECIFIED:DRAWING BASED ON ANSI Y 14.5 SURFACE FINISH 125 ON MACHINED SURFACES. DIMENSIONS SYMMETRICAL ABOUT CENTER LINE WHERE APPLICABLE. ON PLATED PARTS DIMENSIONAL LIMITS APPLY AFTER PLATING. DIMENSIONS OF MOLDED PARTS ARE FOR FINISHED PART. NO ALLOWANCE HAS BEEN MADE FOR SHRINK.

DO NOT SCALE DRAWINGALL DIMENSIONS IN INCHES.REMOVE ALL BURRS.BREAK ALL SHARP EDGES.

TOLERANCES UNLESSOTHERWISE SPECIFIED

DMacRostiePART NUMBER:

APPROVED BY:CHECKED BY:DRAWN BY:

PART NAME

SCALE:

DATE

340 West State St, Unit 22, Athens OH 45701Ecolibrium Solar,Inc. A

FINISH:

SHEET SIZEB

BQuirke BStuart

MATERIAL:

7-12-15 EcoMount Flyer.indd 2 9/10/2015 1:21:41 PM