608 State St. South Kirkland, WA 98033 www.faira.com [email protected] +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, WA 98059 March 21, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property. You may view more detailed information for this home and can make an offer at http://www.faira.com/listings/11893 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due- diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

608 State St. South Kirkland, WA 98033

www.faira.com

[email protected] +1.800.571.FAIR

FAIRA TRANSPARENCY REPORTS

14622 182nd Ave SE, Renton, WA 98059

March 21, 2018

Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property.

You may view more detailed information for this home and can make an offer at

http://www.faira.com/listings/11893 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

Page 2: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West ConsultantsProperty Inspection Report

Cover Page

14622 182nd Ave SE, Renton, WA 98059Inspection prepared for: Faira .com

Real Estate Agent: Faira .com - Faira

Date of Inspection: 4/3/2018 Time: 10:00 AM Age of Home: 1968 Size: 1980 Weather: Cloudy 49 degrees

Order ID: 3461 Front door faces West for orientation purposes only.

Inspector: Dee Robert InmanLicense #1459 UAS Pilots Lic. No. 3976466

Email: [email protected]

Page 3: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 1 of 58

Inspection Details INTRODUCTION: We appreciate the opportunity to conduct this inspection for you!   Please carefully read your entireInspection Report.  Call us after you have reviewed your report, so we can go over any questionsyou may have.  Remember, when the inspection is completed and the report is delivered, we are stillavailable to you for any questions you may have, throughout the entire closing process. Properties being inspected do not "Pass" or "Fail.” -  The following report is based on an inspectionof the visible portion of the structure; inspection may be limited by vegetation and possessions. Depending upon the age of the property, some items like GFCI outlets may not be installed; thisreport will focus on safety and function, not current code. This report identifies specific non-code,non-cosmetic concerns that the inspector feels may need further investigation or repair. For your safety and liability purposes, we recommend that licensed contractors evaluate and repairany critical concerns and defects.  Note that this report is a snapshot in time. We recommend thatyou or your representative carry out a final walk-through inspection immediately before closing tocheck the condition of the property, using this report as a guide. Items denote serious, safety or items that required further investigationItems denote minor or maintenance itemsItems denote locations and shutoff valves

1. AttendanceIn Attendance: Seller present

2. Home TypeHome Type: Split Foyer Style - Two Levels

3. OccupancyOccupancy:• Occupied - Furnished• The utilities were on at the time of inspection.

Page 4: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 2 of 58

General Exterior Note 1. Exterior NoteObservations:• North Elevation• South Elevation• East Elevation• West Elevation

||2||West Elevation ||2||North Elevation

||2||South Elevation ||2||East Elevation

Page 5: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 3 of 58

Exterior Areas 1. Siding ConditionSiding appeared in good condition overall. • Cedar Bevel Siding

Cedar bevel siding in good condition2. GuttersGutters and downspouts appeared in good condition overall.Observations:• Debris in gutters, recommend cleaning gutters.

3. Driveway and Walkway ConditionConcrete sidewalks appeared in good condition overall. • Gravel driveway appeared in goodcondition.Observations:• Driveway and or sidewalk spacers missing, uneven surface. These conditions are potentialtripping hazard. Recommend conditions are repaired as a safety precaution

Page 6: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 4 of 58

East patio

4. SoffitSoffits and eaves appeared in good condition overall.Observations:• Some blistering of paint at soffits noted recommend scraping, prime and paint

Page 7: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 5 of 58

Some bolstering noted at soffits5. Door/WindowExterior doors appeared in operable condition, at time of inspection. • Threshold and jambsappeared in good condition overall. • Window frames and sills appeared in good condition overall.

6. GradingGrading appeared in good condition overall.

Page 8: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 6 of 58

West yard South yard

East yard7. ElectricalExterior outlets operate overall • Exterior outlets are GFCI protected overall • Exterior lightsattached to the house operate overall.

8. Cable FeedsMaterials: Primary Service is Overhead Service DropObservations:• Wires are touching trees, recommend review by the local utility company for repair as necessary.

Page 9: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 7 of 58

9. Gas ConditionMeter located at South side. Main Gas shutoff is located to the lower left of the meter.

Main Gas Shutoff10. Exterior Faucet ConditionExterior faucets were in operable condition overall.Observations:• West hose bib is not frost free type. Recommend winterizing during the cold months.

11. Pressure70 psi

Page 10: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 8 of 58

70 psi12. Gate ConditionMaterials: Chain linkObservations:• Fences are NOT INCLUDED as part of a home inspection.

Page 11: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 9 of 58

Deck 1 1. Deck1East

2. DeckDecking and Visible framing appeared in good condition overall. • Deck surface is covered withwater proof membrane, appeared in good condition overall. • Guardrail appeared secure. •Handrail appeared secure.Observations:• Guardrail not present at stairway, recommend installing guardrail to prevent accidental falling.• South deck is not designed for a hot tub load. Recommend further investigation by licensed deckcontractor

No guardrail in place

Page 12: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 10 of 58

Page 13: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 11 of 58

Roof 1. Roof ConditionComposition shingle roof surface. • Roof surface is appeared in fair condition overall. • Walked onroof surface.Type Average life span 20 years for this type surface with proper maintenance and care.Observations:• Some granular loss at the west slope noted.

Some granular loss at the west slope2. ChimneyBrick masonry chimney appeared in good condition overall, chimney height was adequate overall.

Page 14: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 12 of 58

Page 15: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 13 of 58

Attic 1 1. AtticAttic access is located in the hallway

2. FramingVisible framing appeared in good condition overall, no visible indications of decay or waterpenetration presently.

Page 16: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 14 of 58

3. VentilationVentilation appeared adequate overall. • Under eave soffit inlet vents noted. • Roof surface ventspresent.

4. Fan/DuctBathroom fans appeared to exhaust to the exterior overall. • Kitchen fan appeared to exhaust tothe exterior overall.

Page 17: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 15 of 58

5. Insulation ConditionBlown in cellulose insulation noted.Depth: Insulation averages about 12-14 inches in depth, estimated R value 38

6. Rodent/PestsNo visible indications of Rodent Activity.

Page 18: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 16 of 58

General Interior Note 1. General NotesMaterials: Windows in the home are Double pane insulated glass windows. Any deficiencies arenoted in each room section for accessible windows • Doors in the home are considered operationalunless otherwise noted in each room section

Page 19: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 17 of 58

Entryway 1. ConditionsCeiling and walls are in good condition overall. Light fixture operates. Entry door operates andlocks overall. • Tile floor is in good condition.

Page 20: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 18 of 58

Stairs Leading to 2nd Floor 1. StairSteps appeared uniform. • Handrail appeared secure.

Page 21: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 19 of 58

Living Room 1. Living RoomWalls and ceilings appear in good condition overall. Flooring is wood. Heat register present.Accessible outlets operate.

2. FireplaceFireplace was wood burning type. • Damper is in place.Observations:• Creosote buildup in the fireplace, recommend cleaning by licensed chimney sweep before using.• Cracking/voids in the firebox area, strongly recommend resealing.

Page 22: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 20 of 58

Dining Room 1. LocationLocation Northeast

2. Dining RoomWalls and ceilings appear in good condition overall. Flooring is wood. Heat register present.Accessible outlets operate.

3. DoorsObservations:• Sliding door missing door lock. Recommend repairs

4. FloorObservations:• Wood floor finish sun bleached.

5. Ceiling FanMaterials: Ceiling Fan was in operable condition overall

Page 23: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 21 of 58

Kitchen 1. Kitchen RoomWalls and ceilings appear in good condition overall. Flooring is Tile. Heat register present.Accessible outlets operate. Light fixture operates. Sink and faucets are in operable conditionoverall. Cabinet doors and drawers are in operable condition overall.

2. Counter ConditionGranite counter tops are in good condition.

3. CabinetCabinet doors and drawers are in operable condition overall.

4. DisposalThere is no disposal.

5. DishwasherDishwasher was in operable condition.

6. MicrowaveObservations:• Built-in microwave ovens are tested using normal operating controls. Unit was tested andappeared to be serviceable at time of inspection. Leak and/or efficiency testing is beyond the scopeof this inspection. If concerned, client should seek further review by qualified technician prior toclosing.

7. Stove/OvenStove/oven were in operable condition overall.

Page 24: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 22 of 58

8. RefrigeratorRefrigerator was in operable condition.

Refrigerator temp Freezer temp9. SinksSink was in operable condition overall.Observations:• Flex drain observed, these are subject to frequent clogging.

Page 25: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 23 of 58

Flex drain10. ElectricalOutlets are GFCI protected at the counters.

11. Vent ConditionVent fan appears to exhaust to the exterior, part of microwave.

12. HeatingHeat register operates.

Page 26: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 24 of 58

Hallway 1. ConditionsCeiling and walls are in good condition overall. Light fixture operates. • Accessible outlets operate.

Page 27: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 25 of 58

Master Bedroom 1. LocationLocation South

2. BedroomWalls and ceilings appear in good condition overall. Flooring is wood in good condition overall.Heat register present. Accessible outlets operate.

3. HeatingHeat register operates.

4. Ceiling FanMaterials: Ceiling Fan was in operable condition overall

Page 28: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 26 of 58

Master Bathroom 1. LocationMaterials: Bedroom

2. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates.

3. ElectricalGFI outlets within 6 feet of the water sources.

4. CountersFormica counter tops are in good condition overall.

5. CabinetsCabinet doors are in operable condition overall.

6. SinksSink was in operable condition overall.

7. Exhaust FansVent fan operates overall.

8. FloorsTile Flooring is in good condition overall.

9. ShowerShower is in good condition overall. • Shower door is in operable condition overall.

10. ToiletToilet was in operable condition overall.

11. HeatingHeat register operates.

Page 29: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 27 of 58

Hall Bathroom1 1. LocationMaterials: Upstairs

2. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates.

3. ElectricalGFI outlets within 6 feet of water sources.

4. CountersFormica counter tops are in good condition overall.

5. CabinetsCabinet doors and drawers are in operable condition overall.

6. Exhaust FansVent fan operates overall.Observations:• Exhaust fan vibrates or is excessively noisy. The fan may eventually need to be replaced tocorrect this condition.

7. FloorsTile Flooring is in good condition overall.

8. TubTub and shower were in good condition overall.

9. ShowerShower door is in operable condition overall.

10. SinksSink was in operable condition overall.Observations:• Stopper did not seal tight or function correctly.

Page 30: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 28 of 58

11. ToiletToilet was in operable condition overall.

12. HeatingHeat register operates.

Page 31: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 29 of 58

Bedroom 1 1. LocationLocation 1st Right

2. Bedroom RoomWalls and ceilings appear in good condition overall. Flooring is wood. Heat register present.Accessible outlets operate. • Light fixture operates.

3. HeatingHeat register operates.

Page 32: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 30 of 58

Stairs Leading to Basement 1. StairSteps appeared uniform. • Handrail appeared secure.

Page 33: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 31 of 58

Basement Hallway 1. ConditionsCeiling and walls are in good condition overall. Light fixture operates. • Tile flooring is in goodcondition. • Accessible outlets operate.

Page 34: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 32 of 58

Basement Family Room 1. Family RoomWalls and ceilings appear in good condition overall. Flooring is carpet in good condition. Heatregister present. Accessible outlets operate. • Light fixture operates.

2. FireplaceFireplace is a gas unit. • Fireplace appeared in operable condition.Observations:• Gas shutoff is located at the wall adjacent to the fireplace.• Pilot Controls are located inside access panel under glass.• Recommend cleaning fireplace glass, if discoloration is left for long periods it can become etchedin the glass.

||2||Pilot Controls are located inside access panelunder glass.

Page 35: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 33 of 58

Gas shutoff at adjacent wall3. DoorsObservations:• Entry door does not catch, minor adjustment to strike plate may remedy this condition.• Sliding door is difficult to operate

Page 36: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 34 of 58

Basement Bathroom 1. LocationMaterials: Basement

2. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates.

3. ElectricalGFI outlets within 6 feet of water sources.

4. CountersFormica counter tops are in good condition overall.

5. CabinetsCabinet doors are in operable condition overall.

6. Exhaust FansVent fan operates overall.

7. FloorsTile Flooring is in good condition overall.

8. ShowerShower is in good condition overall. • Shower door is in operable condition overall.

9. SinksSink was in operable condition overall.

10. ToiletToilet was in operable condition overall.

11. HeatingHeat lamp operates. • Ceiling electric convector heater operates.

Page 37: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 35 of 58

Basement Bedroom 1 1. Bedroom RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate. • Light fixture operates.

2. HeatingHeat register operates.

Page 38: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 36 of 58

Basement Laundry Room 1. ConditionCeiling and walls are in good condition overall. Accessible outlets operate. • Light fixture operates.

2. Exhaust FansWindow only, no vent fan.

3. DryerDryer appeared to exhaust to the exterior. • Dryer is electric Unit • 220 volt electrical service forelectric dryer.

Page 39: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 37 of 58

Dryer is operational4. Floor ConditionTile Flooring is in good condition overall.

5. WasherMaterials: Washer appeared to be in operable condition. • Washer faucets were in operablecondition, no visible leakage.

Page 40: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 38 of 58

Mud Room 1. Mud RoomWalls and ceilings appear in good condition overall. Flooring is tile in good condition overall. • Lightfixture operates. • Heat Register present.

Page 41: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 39 of 58

Garage 1. ConditionWalls and ceilings appeared in good condition overall. Accessible outlets operate. Light fixturesoperate overall. Flooring is concrete, visible portions in good condition overall.

2. Floor ConditionMaterials: Flooring is concrete, appeared in good condition overall.

3. ElectricalObservations:• Outlets are not GFCI protected, recommend GFCI protecting outlets as a safety precaution

4. DoorsEntry door is in operable condition overall.

5. Garage DoorsSingle garage door operates, was on auto opener. • Photo cell safety returns operate overall. •Tension safety returns operate overall.

Page 42: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 40 of 58

Garage 2 1. ConditionWood frame walls and ceilings appeared in good condition overall. • Outlets are GFI protected atwalls.

Page 43: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 41 of 58

2. Floor ConditionMaterials: Flooring is concrete, appeared in good condition overall.Observations:• Cracking at the floor does not appear unusual.

3. DoorsEntry door is in operable condition overall.

4. Garage DoorsDouble garage door was in operable condition, was on auto opener. • Photo cell safety returnsoperate. • Tension safety returns operate.

5. StairObservations:• There is no guardrail on one side of the stairs. Recommend using caution.• Stair rise and run is non conforming. Recommend using caution.

Page 44: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 42 of 58

Garage 2 Exterior 1. Siding ConditionSiding appeared in good condition overall. • Plywood T111 siding

2. GuttersGutters and downspouts appeared in good condition overall.

3. SoffitSoffits and eaves appeared in good condition overall.

4. Door/WindowExterior doors appeared in operable condition, at time of inspection. • Threshold and jambsappeared in good condition overall. • Window frames and sills appeared in good condition overall.

5. ElectricalExterior outlets operate overall • Exterior outlets are GFCI protected overall • Exterior lightsattached to the garage operate overall.

Page 45: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 43 of 58

Heat/AC 1. Heating TypeGas forced air furnace.

2. Heater Location The furnace is located in the laundry roomFurnace is Payne brand • 2 years of age approximately, average life span is 18 to 22 years.

3. Heating conditionObservations:• Service does not appear to have been performed within the last year, recommend serviced bylicensed HVAC contractor.• Drip leg/Sediment trap not installed. Recommend conditions are investigated further by licensedHVAC contractor and conditions corrected as required.

All heat registers tested and have heat

Page 46: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 44 of 58

4. VentingObservations:• Water stains observed at the furnace draft inducer fan. Repair as needed.

Leakage from inducer5. FiltersLocation: Right side of furnace filter location

Page 47: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 45 of 58

Page 48: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 46 of 58

Plumbing/Water Heater1 1. PlumbingWater lines were copper • Drain and waste lines were plastic.Observations:• Sewer scoping is recommended by licensed company due to age of home or trees in proximity ofdrain line.

2. Water Heater ConditionHeater Type: Gas Water heater. • 50 gallonsLocation: The heater is located in the laundry room.Observations:• Drip leg/Sediment trap not installed. Recommend conditions are investigated further by licensedHVAC contractor and conditions corrected as required.• Water heater temperature is in excess of 120 degrees, recommend adjustment to preventaccidental scalding.

3. AgeApproximately 4 years of age, average life span is 10 to 12 years.

Page 49: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 47 of 58

4. ConditionExpansion tank is in place.Observations:• 1 seismic strap, 2 are required.• Water heater does not have a drip pan, at a minimum, recommend installing leak alarm sensor atthe base of the water heater.

5. TPRV ConditionTemperature Pressure Relief Valve (TPR Valve) present.

Page 50: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 48 of 58

Electrical 1 1. LocationMaterials: Located in the Garage

2. Electrical200 AMP service, 4/0 Aluminum service entrance wires.

3. GroundingElectrical service is grounded and bonded.

4. Wiring TypeBreaker system present. Wiring sizes conform to breaker sizes overall. Smaller branch circuit wiringis copper.

5. Subpanel

Page 51: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 49 of 58

Page 52: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 50 of 58

Electrical Panel 2 1. LocationMaterials: Located in the Garage 2

2. Electrical100 AMP service #4 Copper service entrance wires.Observations:• Circuit breakers missing exposing live electrical conductors. Electrocution hazard. stronglyrecommend spacer bars are installed.

3. Wiring TypeBreaker system present. Wiring sizes conform to breaker sizes overall. Smaller branch circuit wiringis copper.

Page 53: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 51 of 58

Shutoffs 1. Shutoff LocationsObservations:• Water Heater gas shutoff is located to the left of the water heater.• Water heater water line shutoff is located above the water heater.• Furnace gas shutoff is located to the left of the furnace.• Furnace disconnect is located to the left of the furnace.• Main water shutoff is located on the south wall of the garage.

||2||Main water shutoff is located on the south wallof the garage.

||2||Water Heater gas shutoff is located to the leftof the water heater.

||2||Water heater water line shutoff is locatedabove the water heater.

||2||Furnace gas shutoff is located to the left of thefurnace.

Page 54: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 52 of 58

||2||Furnace disconnect is located to the left of the furnace.

Page 55: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 53 of 58

Equipment 1. Appliances/EquipmentObservations:• Stove• Refrigerator• Dishwasher• Microwave• Water Heater• Furnace• Washer• Dryer

||2||Dishwasher ||2||Refrigerator

||2||Stove ||2||Microwave

Page 56: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 54 of 58

||2||Washer ||2||Dryer

||2||Water Heater ||2||Furnace

Page 57: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 55 of 58

Carbon Monoxide Detectors 1. Carbon MonoxideObservations:• As of April 1st 2012 it is required that Carbon monoxide detectors are installed on each level andoutside of bedroom areas. Recommend conditions are corrected.

Page 58: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 56 of 58

GlossaryGlossary

Term DefinitionCellulose Cellulose insulation: Ground-up newspaper that is treated with

fire-retardant.Expansion Tank An expansion tank or expansion vessel is a small tank used to

protect closed (not open to atmospheric pressure) water heatingsystems and domestic hot water systems from excessivepressure. The tank is partially filled with air, whosecompressibility cushions shock caused by water hammer andabsorbs excess water pressure caused by thermal expansion.

GFCI A special device that is intended for the protection of personnelby de-energizing a circuit, capable of opening the circuit wheneven a small amount of current is flowing through the groundingsystem.

TPR Valve The thermostat in a water heater shuts off the heating sourcewhen the set temperature is reached. If the thermostat fails, thewater heater could have a continuous rise in temperature andpressure (from expansion of the water). The temperature andpressure could continue to rise until the pressure exceeds thepressure capacity of the tank (300 psi). If this should happen, thesuper-heated water would boil and expand with explosive force,and the tank would burst. The super-heated water turns to steamand turns the water heater into an unguided missile. To preventthese catastrophic failures, water heaters are required to beprotected for both excess temperature and pressure. Usually, themeans of protection is a combination temperature- and pressure-relief valve (variously abbreviated as T&P, TPV, TPR, etc.). Mostof these devices are set to operate at a water temperature above200° F and/or a pressure above 150 psi. Do not attempt to testthe TPR valve yourself! Most water heating systems should beserviced once a year as a part of an annual preventivemaintenance inspection by a professional heating and coolingcontractor. From Plumbing: Water Heater TPR Valves

Page 59: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 57 of 58

Report SummaryReport Summary

The summary below consists of potentially significant findings. These findings can be a safetyhazard, a deficiency requiring a major expense to correct or items I would like to draw extra attentionto. The summary is not a complete listing of all the findings in the report, and reflects the opinion ofthe inspector. Please review all pages of the report as the summary alone does not explain all of theissues. All repairs should be done by a licensed & bonded tradesman or qualified professional. Irecommend obtaining a copy of all receipts, warranties and permits for the work done.Exterior AreasPage 3 Item: 3 Driveway and

Walkway Condition• Driveway and or sidewalk spacers missing, uneven surface.These conditions are potential tripping hazard. Recommendconditions are repaired as a safety precaution

Page 6 Item: 8 Cable Feeds • Wires are touching trees, recommend review by the localutility company for repair as necessary.

Deck 1Page 9 Item: 2 Deck • Guardrail not present at stairway, recommend installing

guardrail to prevent accidental falling.• South deck is not designed for a hot tub load. Recommendfurther investigation by licensed deck contractor

Living RoomPage 19 Item: 2 Fireplace • Creosote buildup in the fireplace, recommend cleaning by

licensed chimney sweep before using.• Cracking/voids in the firebox area, strongly recommendresealing.

GaragePage 39 Item: 3 Electrical • Outlets are not GFCI protected, recommend GFCI protecting

outlets as a safety precautionGarage 2Page 41 Item: 5 Stair • There is no guardrail on one side of the stairs. Recommend

using caution.• Stair rise and run is non conforming. Recommend usingcaution.

Heat/ACPage 44 Item: 4 Venting • Water stains observed at the furnace draft inducer fan.

Repair as needed.Plumbing/Water Heater1Page 46 Item: 2 Water Heater

Condition• Water heater temperature is in excess of 120 degrees,recommend adjustment to prevent accidental scalding.

Page 47 Item: 4 Condition • 1 seismic strap, 2 are required.• Water heater does not have a drip pan, at a minimum,recommend installing leak alarm sensor at the base of thewater heater.

Electrical Panel 2Page 50 Item: 2 Electrical • Circuit breakers missing exposing live electrical conductors.

Electrocution hazard. strongly recommend spacer bars areinstalled.

Carbon Monoxide Detectors

Page 60: FAIRA TRANSPARENCY REPORTS 14622 182nd Ave SE, Renton, … · RW West Consultants 14622 182nd Ave SE, Renton, WA Page 7 of 58 9. Gas Condition Meter located at South side. Main Gas

RW West Consultants 14622 182nd Ave SE, Renton, WA

Page 58 of 58

Page 55 Item: 1 Carbon Monoxide • As of April 1st 2012 it is required that Carbon monoxidedetectors are installed on each level and outside of bedroomareas. Recommend conditions are corrected.