THE ART AND SCIENCE OF DEFIBRILLATION ™
ReviveR™ VIEW Semi-Automatic DefibrillatorFULL-COLOR VIDEO INSTRUCTION DELIVERS BREAKTHROUGH EASE-OF-USE
The ReviveR™ VIEW makes it easy for anyone—from first responders to untrained bystanders—to respond confidently and appropriately duringan emergency. This revolutionary life-saving devicecombines a sleek, user-friendly design withmilitary-grade specifications—including the mostproven biphasic waveform. It’s also the first andonly AED with a full-color interactive display thatshows step-by-step videos for performing CPR,rescue breathing and external defibrillation.
You can also be confident that the device will beeasy to maintain and rescue ready. The ReviveR™
VIEW provides clear guidance for using andmaintaining the device. Additionally, it has beendesigned to support upgrades and enhancements.
Like the original award-winning Defibtech AED, theReviveR™ VIEW includes all the mission-criticalfeatures necessary to provide the most advancedcardiac treatment and exceeds the AmericanHeart Association performance recommendations.
Defibtech, LLC | 741 Boston Post Road, Guilford, CT 06437 | www.defibtech.com866-DEFIB-4U (866-333-4248) or 203-453-4507
FactSheets_update.qxd:Layout 1 1/27/10 2:39 PM Page 3
ReviveR™ VIEW Semi-Automatic DefibrillatorTECHNICAL SPECIFICATIONS*
DEFIBRILLATOR
TYPESemi-Automatic external defibrillator
MODELDDU-2300 series
WAVEFORMBiphasic Truncated Exponential(Impedance compensated)
ENERGYAdult: 150 JoulesChild / Infant: 50 Joules(Nominal into 50 Ohm load)
CONTROLSLighted On/Off buttonLighted Shock button
CHARGE TIME**Less than 4 seconds(shock decision to shock)
DISPLAYHigh-resolution color LCD
VIDEO PROMPTSFull motion videoOn-screen text prompts
CPR COACHINGVideo and voice coachingOn-demand video help
VOICE PROMPTSExtensive voice prompts guideuser through operation of the unit
RESCUE PROTOCOLAHA 2005Supports protocol updates bythe user (password protected)
DEFIBRILLATION / MONITORING PADS
MODELAdult – DDP-2001Child / Infant – DDP-2002
TYPEPre-connected, single-use,non-polarized, disposable,self-adhesive electrodes withcable and connector
SURFACE AREA77 cm2 (nominal, each pad)50 cm2 (nominal, each pad)
EVENT DOCUMENTATION
INTERNAL EVENT RECORDCritical ECG segments and rescueevent parameters are recorded(greater than 60 minutes) andcan be downloaded to a removabledata card
PC-BASED EVENT REVIEWECG with event tag display, andaudio playback when available
REMOVABLE STORAGE(optional) Up to 30 hours of ECGand event data storage (no audiooption) or up to 3 hours of audio(audio option). ECG and eventstorage on a removable data card.Actual length of storage isdependent on card capacity.
USB PORTEvent download andmaintenance operations
ENVIRONMENTAL
TEMPERATUREOperating: 0 to 50°C (32 to 122°F)Standby: 0 to 50°C (32 to 122°F)
RELATIVE HUMIDITYOperating / Standby: 5%-95%(non-condensing)
ALTITUDE-500 to 15,000 ft (-150 to 4500 m)per MIL-STD-810F 500.4 Procedure ll
VIBRATIONGround (MIL-STD-810F 514.5Category 20)
Helicopter (RTCA/DO-160D,Section 8.8.2, Cat R. Zone 2,Curve G)
Jet Aircraft (RTCA/DO-160DSection 8. Cat H, Zone 2,Curves B & R)
SHOCK / DROP ABUSETOLERANCEMIL-STD-810F 516.5 Procedure IV48 inches (1.2 meters), any edge,corner, or surface, in standby mode
CRUSH TEST1,000 pounds (450 kg)
SEALING / WATERRESISTANCEIEC60529 class IP55; Protectedagainst dust and waterjets(battery pack installed)
ESDEN61000-4-2: (Open air up to8kV or direct contact up to 6kV)
EMC (Emission)CISPR 11 Group 1 Level B andFCC Part 15
EMC (Immunity)IEC 61000-4-3 and IEC 61000-4-8
PATIENT ANALYSIS SYSTEM
PATIENT ANALYSISAutomatically evaluates patientimpedance for proper pad contact.Monitors signal quality and analyzespatient ECG for shockable/non-shockable rhythms.
SENSITIVITY/SPECIFICITYMeets AAMI-DF-80 specificationsand AHA recommendations
PHYSICAL
SIZE7.3 x 9.5 x 2.3 Inches(18.5 x 24 x 5.8 cm)
WEIGHTLess than 3 lbs (1.4 kg)(with battery)
SELF TESTS
AUTOMATICAutomatic daily, weekly andmonthly circuitry tests
BATTERY INSERTIONSystem integrity test on batteryinsertion
PAD PRESENCEPads preconnected tested daily
USER-INITIATEDUnit and battery pack systemtest initiated by the user
STATUS INDICATIONVisual and audible indication ofunit status
STATUS SCREENUnit self-test resultsPads and battery information(status and expiration)
BATTERY PACK
0197
MODELDBP-2003
POWER12V, 2800 mAh
TYPELithium/Manganese DioxideDisposable, recyclable,non-rechargeable
CAPACITY**125 shocks or 8 hourscontinuous operation
STANDBY LIFE**4 years
LOW BATTERY INDICATORSVisibleAudible
**Typical, with new battery at 25° C
DAC-C2703EN-AB rev B
**Typical, with new battery at 25° C
Defibtech, LLC • Guilford, CT 06437 1-203-453-45071-866-DEFIB-4U (866-333-4248) • www.defibtech.com
*Specifications subject to change without notice
US