Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
Facility Summary in GLACIER County in the City of BABB
LARIAT MOTEL
US HWY 89
Sys Fac ID:
BABB, MT 59411 GLACIER
18-02264
Operating Permit Renewal Date:
Last Inspected On:
Location:
Bob Burns, (406) 732-4532Contact:
Owners/Operators: Robert Burns, Owner/Operator PO BOX 190BABB MT 59411-0190
(406)-732-4532
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Temporarily Out of Use
1
Diesel
4,000
Bare Steel Steel
None None
4/25/1982
Not Listed
36
No
Not Listed Not Listed
4/25/1992
Temporarily Out of Use
2
Gasoline
4,000
Bare Steel Steel
None None
4/25/1982
Not Listed
36
No
Not Listed Not Listed
4/25/1992
Temporarily Out of Use
3
Gasoline
10,000
Bare Steel Steel
None None
4/25/1985
Not Listed
33
No
Not Listed Not Listed
4/25/1995
Report Generation Date: 12/12/2018 Page 643
Facility Summary in GLACIER County in the City of BABB
THRONSONS STORE
US HWY 89
Sys Fac ID:
BABB, MT 59411 GLACIER
18-03871
Operating Permit Renewal Date: 9/3/2020
Last Inspected On: 5/11/2017
Location:
Michael Thronson, (406) 732-5530Contact:
Owners/Operators: Thronsons Store, Owner/Operator PO BOX 169BABB MT 59411-0169
(406)-732-5530
Michael Thronson, UST Class A Operator
Michael Thronson, UST Class B Global Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
1
Gasoline
7,000
Cathodically Protected Steel Fiberglass Reinforced Plastic
Double-Walled None
12/31/1989
Pressurized
28
4401 Yes
Ball Float Valve
Galvanic
Manual Interstitial Monitor MLLD Line Tightness Testing
Mechanical Line Leak Detector
6/20/2017
12/4/2018
Currently in Use
2
Gasoline
3,000
Cathodically Protected Steel Fiberglass Reinforced Plastic
Double-Walled None
12/31/1989
Pressurized
28
4402 Yes
Ball Float Valve
Galvanic
Manual Interstitial Monitor MLLD Line Tightness Testing
Mechanical Line Leak Detector
6/20/2017
12/4/2018
Currently in Use
3
Gasoline
8,000
Cathodically Protected Steel Fiberglass Reinforced Plastic
Double-Walled None
12/31/1989
Pressurized
28
4403 Yes
Ball Float Valve
Galvanic
Manual Interstitial Monitor MLLD Line Tightness Testing
Mechanical Line Leak Detector
6/20/2017
12/4/2018
Report Generation Date: 12/12/2018 Page 644
Facility Summary in GLACIER County in the City of BROWNING
SCHOOL DIST 9 MAINTENANCE COMPLEX
105 E BOUNDARY ST
Sys Fac ID:
BROWNING, MT 59417 GLACIER
18-03868
Operating Permit Renewal Date: 3/22/2022
Last Inspected On: 9/26/2018
Location:
Wayne Hall, (406) 338-2952Contact:
Owners/Operators: School Dist 9 Browning, Owner PO BOX 610BROWNING MT 59417-0610
(406)-338-2952
Wayne Hall, Operator 742 BOARDING SCHOOL RDBROWNING MT 59417
(406)-338-2952
Wayne Hall, UST Class A Operator
Wayne Hall, UST Class B Global Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
2
Gasoline
8,000
Cathodically Protected Steel Steel
None None
11/29/1986
Safe Suction
32
4130 Yes
Flapper Valve (Auto Shutoff)
Galvanic
Gilbarco EMC Basic , Gilbarco
Automatic Tank Gauging 0.2 Deferred
Not Required
9/26/2018
Currently in Use
3
Diesel
8,000
Steel Clad Steel
None None
11/28/1989
Safe Suction
29
4131 Yes
Flapper Valve (Auto Shutoff)
Galvanic
Gilbarco EMC Basic , Gilbarco
Automatic Tank Gauging 0.2 Deferred
Not Required
9/26/2018
Report Generation Date: 12/12/2018 Page 645
Facility Summary in GLACIER County in the City of BROWNING
COOP'S CORNER CONOCO
330 W CENTRAL AVE
Sys Fac ID:
BROWNING, MT 59417 GLACIER
18-05813
Operating Permit Renewal Date: 3/13/2021
Last Inspected On: 1/17/2018
Location:
Tony Sitzmann, (406) 226-4255Contact:
Owners/Operators: Glacier Park 66 Inc, Owner PO BOX 1609EAST GLACIER PARK MT 59434
(406)-338-2575
Tony Sitzmann, Operator PO BOX 129EAST GLACIER PARK MT 59434-0129
(406)-226-5504
Randy Livingston, UST Class A Operator
Michael Sherwood, UST Class A Operator
Troy Wilson, UST Class A Operator
Randy Livingston, UST Class B Operator
Michael Sherwood, UST Class B Operator
Troy Wilson, UST Class B Global Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
4
Gasoline
20,000
Fiberglass Reinforced Plastic Flexible Plastic
Double-Walled None
1/3/1997
Pressurized
21
4441 Yes
Flapper Valve (Auto Shutoff)
Not Applicable
Gilbarco EMC Basic , Gilbarco
Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2
Electronic Line Leak Detector
12/10/2008
12/10/2008
Currently in Use
5
Diesel
12,000
Fiberglass Reinforced Plastic Flexible Plastic
Double-Walled None
1/3/1997
Pressurized
21
4442 Yes
Flapper Valve (Auto Shutoff)
Not Applicable
Gilbarco EMC Basic , Gilbarco
Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing
Electronic Line Leak Detector
12/10/2008
5/25/2017
Currently in Use
6
Gasoline
12,000
Fiberglass Reinforced Plastic Flexible Plastic
Double-Walled None
1/3/1997
Pressurized
21
4443 Yes
Flapper Valve (Auto Shutoff)
Not Applicable
Gilbarco EMC Basic , Gilbarco
Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing
Electronic Line Leak Detector
12/10/2008
5/25/2017
Report Generation Date: 12/12/2018 Page 646
Facility Summary in GLACIER County in the City of BROWNING
PARK CAFE AND GROCERY
3147 US HWY 89 W HC 72 BOX 5
Sys Fac ID:
BROWNING, MT 59417 GLACIER
18-06436
Operating Permit Renewal Date: 5/30/2020
Last Inspected On: 5/11/2017
Location:
Keith Hilton, (406) 892-2121Contact:
Owners/Operators: Hilton Family Corporation, Owner PO BOX 2895COLUMBIA FALLS MT 59912
(406)-892-5589
Keith Hilton, Operator HC 72 BOX 5BROWNING MT 59417
(406)-250-1193
Keith Hilton, UST Class A Operator
Keith Hilton, UST Class B Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Temporarily Out of Use
1
Diesel
2,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
None None
11/1/1991
Pressurized
27
1382 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Automatic Tank Gauging 0.2 MLLD Line Tightness Testing
Mechanical Line Leak Detector
5/11/2017
Temporarily Out of Use
2
Gasoline
12,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
None None
11/1/1991
Pressurized
27
1380 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Automatic Tank Gauging 0.2 MLLD Line Tightness Testing
Mechanical Line Leak Detector
5/11/2017
Temporarily Out of Use
3
Gasoline
6,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
None None
11/1/1991
Pressurized
27
1381 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Automatic Tank Gauging 0.2 MLLD Line Tightness Testing
Mechanical Line Leak Detector
5/11/2017
Report Generation Date: 12/12/2018 Page 647
Facility Summary in GLACIER County in the City of BROWNING
TOWN PUMP INC BROWNING 2
304 SE BOUNDARY ST
Sys Fac ID:
BROWNING, MT 59417 GLACIER
18-08677
Operating Permit Renewal Date: 4/1/2019
Last Inspected On: 12/28/2015
Location:
Tammy Boyiddle, (406) 388-7866Contact:
Owners/Operators: Major Brands Distributing Imports Inc, Owner PO BOX 6000BUTTE MT 59702-6000
(406)-497-6700
Don Edmisten, Operator 2025 S ARIZONA STBUTTE MT 59701
(406)-497-6948
Don Edmisten, UST Class A Operator
Daniel Sampson, UST Class A Operator
Don Edmisten, UST Class B Global Operator
Daniel Sampson, UST Class B Global Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
1
Diesel
12,000
Fiberglass Reinforced Plastic Flexible Plastic
Double-Walled Double-Walled
6/1/1995
Pressurized
23
2467 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
11/26/2012
11/30/2006
Currently in Use
2
Gasoline
12,000
Fiberglass Reinforced Plastic Flexible Plastic
Double-Walled Double-Walled
6/1/1995
Pressurized
23
2465 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
11/26/2012
11/30/2006
Currently in Use
3
Gasoline
12,000
Fiberglass Reinforced Plastic Flexible Plastic
Double-Walled Double-Walled
6/1/1995
Pressurized
23
2466 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
12/4/2009
11/30/2006
Report Generation Date: 12/12/2018 Page 648
Facility Summary in GLACIER County in the City of BROWNING
TOWN PUMP INC BROWNING 2
304 SE BOUNDARY ST
Sys Fac ID:
BROWNING, MT 59417 GLACIER
18-08677
Operating Permit Renewal Date: 4/1/2019
Last Inspected On: 12/28/2015
Location:
Tammy Boyiddle, (406) 388-7866Contact:
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
4
Diesel
12,000
Fiberglass Reinforced Plastic Flexible Plastic
Double-Walled Double-Walled
6/1/1995
Pressurized
23
4888 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
11/26/2012
11/30/2006
Currently in Use
13
Gasoline
12,000
Fiberglass Reinforced Plastic Flexible Plastic
Double-Walled Double-Walled
6/1/1995
Pressurized
23
2463 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
11/26/2012
12/1/2006
Currently in Use
14
Diesel
10,000
Fiberglass Reinforced Plastic Flexible Plastic
Double-Walled Double-Walled
8/14/2003
Pressurized
15
4859 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
12/4/2009
12/1/2006
Currently in Use
15
Diesel
5,000
Fiberglass Reinforced Plastic Flexible Plastic
Double-Walled Double-Walled
8/14/2003
Pressurized
15
4860 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
11/26/2012
12/1/2006
Report Generation Date: 12/12/2018 Page 649
Facility Summary in GLACIER County in the City of BROWNING
SCHOOL DIST 9 TRANSPORTATION DEPT
829 SW BOUNDARY ST
Sys Fac ID:
BROWNING, MT 59417 GLACIER
18-12747
Operating Permit Renewal Date: 3/22/2022
Last Inspected On: 9/26/2018
Location:
Wayne Hall, (406) 338-2952Contact:
Owners/Operators: School Dist 9 Browning, Owner PO BOX 610BROWNING MT 59417-0610
(406)-338-2952
Wayne Hall, Operator 742 BOARDING SCHOOL RDBROWNING MT 59417
(406)-338-2952
Wayne Hall, UST Class A Operator
Wayne Hall, UST Class B Global Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
1
Waste Oil
1,000
Cathodically Protected Steel Flexible Plastic
None Double-Walled
7/1/1992
Pressurized
26
1900 Yes
High Level Alarm
Impressed Current
Gilbarco EMC Basic , Gilbarco
Automatic Tank Gauging 0.2 Continuous Interstitial Monitor
Continuous Interstitial Monitoring
9/18/2018
9/26/2018
9/8/2009
Currently in Use
2
Gasoline
8,000
Cathodically Protected Steel Fiberglass Reinforced Plastic
None None
7/1/1992
Pressurized
26
1898 Yes
High Level Alarm
Impressed Current
Gilbarco EMC Basic , Gilbarco
Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2
Electronic Line Leak Detector
9/26/2018
9/8/2009
Currently in Use
3
Diesel
8,000
Cathodically Protected Steel Fiberglass Reinforced Plastic
None None
7/1/1992
Pressurized
26
1899 Yes
High Level Alarm
Impressed Current
Gilbarco EMC Basic , Gilbarco
Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2
Electronic Line Leak Detector
9/26/2018
9/8/2009
Report Generation Date: 12/12/2018 Page 650
Facility Summary in GLACIER County in the City of BROWNING
GLACIER WAY CONVENIENCE STORE
200 MT HWY 464 99 MT HWY 464
Sys Fac ID:
BROWNING, MT 59417 GLACIER
18-13768
Operating Permit Renewal Date: 12/20/2020
Last Inspected On: 8/21/2017
Location:
toney sitzman, (406) 338-7163Contact:
Owners/Operators: Pat & Violet Schildt, Owner/Operator PO BOX 1777BROWNING MT 59417-1777
(406)-338-7163
Stacey Keller, UST Class A Operator
Charles Lafley, UST Class A Operator
Harold Schildt, UST Class A Operator
Stacey Keller, UST Class B Global Operator
Charles Lafley, UST Class B Global Operator
Harold Schildt, UST Class B Global Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
1
Gasoline
20,000
Fiberglass Reinforced Plastic Flexible Plastic
Double-Walled Double-Walled
9/25/1996
Pressurized
22
3425 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Automatic Tank Gauging 0.2, Continuous Interstitial Monitor
Continuous Interstitial Monitor
Continuous Interstitial Monitoring
4/20/2018
7/9/2008
Currently in Use
2
Diesel
15,000
Fiberglass Reinforced Plastic Flexible Plastic
Double-Walled Double-Walled
9/25/1996
Pressurized
22
3426 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Automatic Tank Gauging 0.2, Continuous Interstitial Monitor
Continuous Interstitial Monitor
Continuous Interstitial Monitoring
4/20/2018
7/9/2008
Currently in Use
3
Gasoline
10,000
Fiberglass Reinforced Plastic Flexible Plastic
Double-Walled Double-Walled
9/25/1996
Pressurized
22
3427 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Automatic Tank Gauging 0.2, Continuous Interstitial Monitor
Continuous Interstitial Monitor
Continuous Interstitial Monitoring
4/20/2018
7/9/2008
Report Generation Date: 12/12/2018 Page 651
Facility Summary in GLACIER County in the City of BROWNING
GLACIER FAMILY FOODS
601 SE BOUNDARY ST PO BOX 1989
Sys Fac ID:
BROWNING, MT 59417 GLACIER
60-15286
Operating Permit Renewal Date: 10/14/2019
Last Inspected On: 10/12/2016
Location:
Joseph Bremner, (406) 338-3132Contact:
Owners/Operators: Siyeh Development Corporation, Owner/Operator PO BOX 1989BROWNING MT 59417
(406)-338-5669
Roxanne BirdRattler, UST Class A Operator
Joseph Bremner, UST Class A Operator
Dori Goss, UST Class A Operator
Galen Lazyboy, UST Class A Operator
Roxanne BirdRattler, UST Class B Operator
Joseph Bremner, UST Class B Operator
Dori Goss, UST Class B Operator
Galen Lazyboy, UST Class B Global Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
1
Diesel
12,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
Double-Walled Double-Walled
10/1/2015
Pressurized
03
5673 Yes
Positive Shutoff
Not Applicable
TS-550 EVO , Incon
Continuous Interstitial Monitor Continuous Interstitial Monitor, Not Listed
Not Listed
Continuous Interstitial Monitoring
Yes
6/27/2016
Currently in Use
2
Diesel
8,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
Double-Walled Double-Walled
10/1/2015
Pressurized
03
5674 Yes
Positive Shutoff
Not Applicable
TS-550 EVO , Incon
Continuous Interstitial Monitor Continuous Interstitial Monitor, Not Listed
Not Listed
Continuous Interstitial Monitoring
Yes
6/27/2016
Currently in Use
3
Gasoline
20,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
Double-Walled Double-Walled
10/1/2015
Pressurized
03
5675 Yes
Positive Shutoff
Not Applicable
TS-550 EVO , Incon
Continuous Interstitial Monitor Continuous Interstitial Monitor, Not Listed
Not Listed
Continuous Interstitial Monitoring
Yes
Yes
6/27/2016
Report Generation Date: 12/12/2018 Page 652
Facility Summary in GLACIER County in the City of BROWNING
GLACIER FAMILY FOODS
601 SE BOUNDARY ST PO BOX 1989
Sys Fac ID:
BROWNING, MT 59417 GLACIER
60-15286
Operating Permit Renewal Date: 10/14/2019
Last Inspected On: 10/12/2016
Location:
Joseph Bremner, (406) 338-3132Contact:
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
4
Gasoline
8,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
Double-Walled Double-Walled
10/1/2015
Pressurized
03
5676 Yes
Positive Shutoff
Not Applicable
TS-550 EVO , Incon
Continuous Interstitial Monitor Continuous Interstitial Monitor, Not Listed
Not Listed
Continuous Interstitial Monitoring
Yes
Yes
6/27/2016
Report Generation Date: 12/12/2018 Page 653
Facility Summary in GLACIER County in the City of CUT BANK
CUT BANK MUNICIPAL AIRPORT
2705 VALIER HWY
Sys Fac ID:
CUT BANK, MT 59427 GLACIER
18-00137
Operating Permit Renewal Date: 1/31/2020
Last Inspected On: 8/12/2016
Location:
Dan McCoy, (406) 873-8683Contact:
Owners/Operators: Cut Bank Airport Authority, Owner/Operator 2705 VALIER HWYCUT BANK MT 59427
(406)-873-8683
Roy Nollkamper, UST Class A Operator
David Ries, UST Class A Operator
Roy Nollkamper, UST Class B Operator
David Ries, UST Class B Global Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
8
Jet Fuel
12,000
Fiberglass Reinforced Plastic Flexible Plastic
None Double-Walled
11/1/1997
Pressurized
21
793 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Automatic Tank Gauging 0.2 Continuous Interstitial Monitor
Mechanical Line Leak Detector
5/9/2016
Currently in Use
9
Aviation Gas
12,000
Fiberglass Reinforced Plastic Flexible Plastic
None Double-Walled
11/1/1997
Pressurized
21
794 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Automatic Tank Gauging 0.2 Continuous Interstitial Monitor
Mechanical Line Leak Detector
5/9/2016
Report Generation Date: 12/12/2018 Page 654
Facility Summary in GLACIER County in the City of CUT BANK
KENNYS SUPER SERVICE
401 E MAIN ST
Sys Fac ID:
CUT BANK, MT 59427 GLACIER
18-00321
Operating Permit Renewal Date: 11/4/2020
Last Inspected On: 8/21/2017
Location:
Randy Fetters, (406) 873-2432Contact:
Owners/Operators: Kennys Super Service, Owner/Operator 401 E MAIN STCUT BANK MT 59427-3014
(406)-873-2432
Randall Fetters, UST Class A Operator
Randall Fetters, UST Class B Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
1
Gasoline
6,000
Cathodically Protected Steel Fiberglass Reinforced Plastic
None None
6/13/1985
Safe Suction
33
1471 Yes
High Level Alarm
Galvanic
EECO 1500 , EMCO Electronics
Automatic Tank Gauging 0.2 Deferred
Not Required
8/15/2017
Currently in Use
2
Gasoline
6,000
Cathodically Protected Steel Fiberglass Reinforced Plastic
None None
6/13/1985
Safe Suction
33
1472 Yes
High Level Alarm
Galvanic
EECO 1500 , EMCO Electronics
Automatic Tank Gauging 0.2 Deferred
Not Required
8/15/2017
Report Generation Date: 12/12/2018 Page 655
Facility Summary in GLACIER County in the City of CUT BANK
TOWN PUMP INC CUT BANK 2
510 W MAIN ST
Sys Fac ID:
CUT BANK, MT 59427 GLACIER
18-03417
Operating Permit Renewal Date: 4/1/2019
Last Inspected On: 12/28/2015
Location:
Trent Biggers, (406) 497-6700Contact:
Owners/Operators: Town Pump O Mat of Cut Bank Inc, Owner/Operator PO BOX 6000BUTTE MT 59702-6000
(406)-497-6700
Don Edmisten, UST Class A Operator
Daniel Sampson, UST Class A Operator
Don Edmisten, UST Class B Global Operator
Daniel Sampson, UST Class B Global Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
1
Diesel
10,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
None Double-Walled
3/1/1993
Pressurized
25
2459 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
12/2/2009
Currently in Use
2
Gasoline
12,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
None None
3/1/1993
Pressurized
25
2460 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
12/2/2009
Currently in Use
3
Gasoline
12,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
None None
3/1/1993
Pressurized
25
2461 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
12/2/2009
Report Generation Date: 12/12/2018 Page 656
Facility Summary in GLACIER County in the City of CUT BANK
TOWN PUMP INC CUT BANK 2
510 W MAIN ST
Sys Fac ID:
CUT BANK, MT 59427 GLACIER
18-03417
Operating Permit Renewal Date: 4/1/2019
Last Inspected On: 12/28/2015
Location:
Trent Biggers, (406) 497-6700Contact:
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
4
Diesel
12,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
None None
3/1/1993
Pressurized
25
2462 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
12/2/2009
Currently in Use
7
Diesel
10,000
Fiberglass Reinforced Plastic Flexible Plastic
Double-Walled Double-Walled
5/1/2000
Pressurized
18
4185 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
12/2/2009
Currently in Use
8
Diesel
5,000
Fiberglass Reinforced Plastic Flexible Plastic
Double-Walled Double-Walled
5/1/2000
Pressurized
18
4186 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
12/2/2009
Report Generation Date: 12/12/2018 Page 657
Facility Summary in GLACIER County in the City of CUT BANK
BEN TAYLOR INC - CUT BANK BULK PLANT
201 BN INDUSTRIAL SITE
Sys Fac ID:
CUT BANK, MT 59427 GLACIER
18-04137
Operating Permit Renewal Date: 11/17/2019
Last Inspected On: 11/11/2016
Location:
Shannon Gabbard, (406) 289-0525Contact:
Owners/Operators: Ben Taylor Inc, Owner/Operator PO BOX 810SHELBY MT 59474-0810
(800)-824-8366
Shannon Gabbard, UST Class A Operator
Shannon Gabbard, UST Class B Operator
Gregory Taylor, UST Class B Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
16
Gasoline
34,000
Unknown Flexible Plastic
None Double-Walled
10/29/2000
Pressurized
18
Yes4241 Yes
Not Applicable
Gilbarco EMC Basic , Gilbarco
Deferred Continuous Interstitial Monitor
Continuous Interstitial Monitoring
4/18/2014
Currently in Use
17
Gasoline
11,700
Unknown Flexible Plastic
None Double-Walled
10/29/2000
Pressurized
18
Yes4242 Yes
Not Applicable
Gilbarco EMC Basic , Gilbarco
Deferred Continuous Interstitial Monitor
Continuous Interstitial Monitoring
4/18/2014
Currently in Use
18
Diesel
12,500
Unknown Flexible Plastic
None Double-Walled
10/29/2000
Pressurized
18
Yes4243 Yes
Not Applicable
Gilbarco EMC Basic , Gilbarco
Deferred Continuous Interstitial Monitor
Continuous Interstitial Monitoring
4/18/2014
Currently in Use
19
Diesel
34,000
Unknown Flexible Plastic
None Double-Walled
10/29/2000
Pressurized
18
Yes4244 Yes
Not Applicable
Gilbarco EMC Basic , Gilbarco
Deferred Continuous Interstitial Monitor
Continuous Interstitial Monitoring
4/18/2014
Report Generation Date: 12/12/2018 Page 658
Facility Summary in GLACIER County in the City of CUT BANK
BEN TAYLOR INC - CUT BANK BULK PLANT
201 BN INDUSTRIAL SITE
Sys Fac ID:
CUT BANK, MT 59427 GLACIER
18-04137
Operating Permit Renewal Date: 11/17/2019
Last Inspected On: 11/11/2016
Location:
Shannon Gabbard, (406) 289-0525Contact:
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
20
Diesel
12,500
Unknown Flexible Plastic
None Double-Walled
10/29/2000
Pressurized
18
Yes4245 Yes
Not Applicable
Gilbarco EMC Basic , Gilbarco
Deferred Continuous Interstitial Monitor
Continuous Interstitial Monitoring
4/18/2014
Currently in Use
21
Diesel
11,700
Unknown Flexible Plastic
None Double-Walled
10/29/2000
Pressurized
18
Yes4246 Yes
Not Applicable
Gilbarco EMC Basic , Gilbarco
Deferred Continuous Interstitial Monitor
Continuous Interstitial Monitoring
4/18/2014
Report Generation Date: 12/12/2018 Page 659
Facility Summary in GLACIER County in the City of CUT BANK
HARVEST STATES COOP CUT BANK
29 N CENTRAL AVE
Sys Fac ID:
CUT BANK, MT 59427 GLACIER
18-13623
Operating Permit Renewal Date:
Last Inspected On:
Location:
Chuck Gatzemeier, (406) 873-2081Contact:
Owners/Operators: Harvest States Coop Cut Bank, Owner/Operator PO BOX 1272CUT BANK MT 59427-1272
(406)-873-2081
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
1
Hazardous Substance
1,000
Unknown Steel
None None
5/20/1995
Safe Suction
23
Yes Yes
Deferred Not Listed
Report Generation Date: 12/12/2018 Page 660
Facility Summary in GLACIER County in the City of CUT BANK
SIMONS PETROLEUM
813 E RAILROAD ST
Sys Fac ID:
CUT BANK, MT 59427 GLACIER
56-13775
Operating Permit Renewal Date: 7/30/2020
Last Inspected On: 1/12/2017
Location:
Steve Nelson, (406) 873-4612Contact:
Owners/Operators: Ben Taylor Inc, Owner/Operator PO BOX 810SHELBY MT 59474-0810
(800)-824-8366
Steve Nelson, UST Class A Operator
Pat Simons, UST Class A Operator
Justin Aikins, UST Class B Operator
Steve Nelson, UST Class B Operator
Joseph Pehan, UST Class B Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
1
Diesel
12,000
Bare Steel Flexible Plastic
None Double-Walled
10/31/1997
Pressurized
21
Yes1928 Yes
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Deferred Automatic Tank Gauging 0.2
Continuous Interstitial Monitor
Electronic Line Leak Detector
3/2/2012
Currently in Use
2
Gasoline
8,000
Bare Steel Flexible Plastic
None Double-Walled
10/31/1997
Pressurized
21
Yes1929 Yes
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Deferred Automatic Tank Gauging 0.2
Continuous Interstitial Monitor
Electronic Line Leak Detector
3/2/2012
Currently in Use
3
Diesel
11,800
Unknown Flexible Plastic
None Double-Walled
3/1/2012
Pressurized
06
Yes5494 No
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Deferred Automatic Tank Gauging 0.2
Continuous Interstitial Monitor
Electronic Line Leak Detector
3/2/2012
Report Generation Date: 12/12/2018 Page 661
Facility Summary in GLACIER County in the City of CUT BANK
TOWN PUMP OF CUT BANK #3
1119 E MAIN ST
Sys Fac ID:
CUT BANK, MT 59427 GLACIER
60-15144
Operating Permit Renewal Date: 12/11/2021
Last Inspected On: 6/15/2018
Location:
Trent Biggers, (406) 497-6700Contact:
Owners/Operators: Manhattan Holdings LLC, Owner/Operator PO BOX 6000BUTTE MT 59702-6000
(406)-497-6946
Don Edmisten, UST Class A Operator
Don Edmisten, UST Class B Global Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
1
Gasoline
20,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
Double-Walled Double-Walled
7/3/2010
Pressurized
08
5227 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
Currently in Use
2
Diesel
12,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
Double-Walled Double-Walled
7/3/2010
Pressurized
08
5228 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
Currently in Use
3
Gasoline
8,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
Double-Walled Double-Walled
7/3/2010
Pressurized
08
5229 Yes
Ball Float Valve
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring
Stat. Inventory Reconcilitation, Approved Remote Monitoring
Continuous Interstitial Monitor
Electronic Line Leak Detector
Report Generation Date: 12/12/2018 Page 662
Facility Summary in GLACIER County in the City of EAST GLACIER PARK
SEARS MOTEL & GIFT SHOP
1023 HWY 49 N
Sys Fac ID:
EAST GLACIER PARK, MT 59434 GLACIER
18-03870
Operating Permit Renewal Date: 12/31/2020
Last Inspected On: 8/29/2017
Location:
Judy Jones, (406) 226-4432Contact:
Owners/Operators: Judy Jones, Owner/Operator PO BOX 275EAST GLACIER PARK MT 59434-0275
(406)-226-4432
Judy Jones, UST Class A Operator
Judy Jones, UST Class B Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Temporarily Out of Use
2
Gasoline
2,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
None None
9/28/1990
Safe Suction
28
1453 Yes
Flapper Valve (Auto Shutoff)
Not Applicable
Gilbarco EMC Basic , Gilbarco
Automatic Tank Gauging 0.2 Deferred
Not Required
Temporarily Out of Use
3
Gasoline
2,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
None None
9/1/1990
Safe Suction
28
1454 Yes
Flapper Valve (Auto Shutoff)
Not Applicable
Gilbarco EMC Basic , Gilbarco
Automatic Tank Gauging 0.2 Deferred
Not Required
Report Generation Date: 12/12/2018 Page 663
Facility Summary in GLACIER County in the City of EAST GLACIER PARK
BEAR TRACK TRAVEL CENTER
20958 US HWY 2
Sys Fac ID:
EAST GLACIER PARK, MT 59434 GLACIER
56-13933
Operating Permit Renewal Date: 6/30/2019
Last Inspected On: 3/24/2016
Location:
Clifford Fortune, (406) 226-5504Contact:
Owners/Operators: Fortune Development Corp, Owner PO BOX 468EAST GLACIER PARK MT 59434-0468
(406)-226-5504
Clifford J Fortune, Operator 20958 HWY 2EAST GLACIER PARK MT 59434
(406)-226-5504
Julie Fortune, UST Class A Operator
Jim Fortune, UST Class B Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
1
Diesel
8,000
Unknown Flexible Plastic
Double-Walled Double-Walled
6/1/1999
Pressurized
19
Yes4068 Yes
High Level Alarm
Not Applicable
TLS-300 , Veeder Root
Deferred Automatic Tank Gauging 0.2, ELLD Line Tightness Testing
Electronic Line Leak Detector
Currently in Use
2
Gasoline
5,000
Unknown Flexible Plastic
Double-Walled Double-Walled
6/1/1999
Pressurized
19
Yes4069 Yes
High Level Alarm
Not Applicable
TLS-300 , Veeder Root
Deferred Automatic Tank Gauging 0.2, ELLD Line Tightness Testing
Electronic Line Leak Detector
Currently in Use
3
Gasoline
12,000
Concrete Flexible Plastic
Double-Walled Double-Walled
9/14/2007
Pressurized
11
Yes5126 Yes
High Level Alarm
Not Applicable
TLS-300 , Veeder Root
Deferred Automatic Tank Gauging 0.2, ELLD Line Tightness Testing
Electronic Line Leak Detector
Yes
Report Generation Date: 12/12/2018 Page 664
Facility Summary in GLACIER County in the City of SAINT MARY
ST MARY LODGE
3 GOING TO THE SUN RD ST MARY LAKE
Sys Fac ID:
SAINT MARY, MT 59411 GLACIER
18-01907
Operating Permit Renewal Date: 10/20/2020
Last Inspected On: 5/11/2017
Location:
Walter Kochansky, (406) 732-4431Contact:
Owners/Operators: Glacier Park Inc, Owner/Operator PO BOX 147EAST GLACIER PARK MT 59434
(406)-226-5631
Jon Noe, UST Class A Operator
Lisa Wyrick, UST Class A Operator
Bob Hines, UST Class B Operator
Lisa Wyrick, UST Class B Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
1
Gasoline
7,000
Cathodically Protected Steel Fiberglass Reinforced Plastic
None Secondary Containment Chase
6/1/1990
Pressurized
28
453 Yes
Ball Float Valve
Galvanic
TLS-350/Gilbarco EMC , Veeder Root
Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing
Electronic Line Leak Detector
5/29/2017
10/17/2007
Currently in Use
2
Diesel
3,000
Cathodically Protected Steel Fiberglass Reinforced Plastic
None Secondary Containment Chase
6/1/1990
Pressurized
28
454 Yes
Ball Float Valve
Galvanic
TLS-350/Gilbarco EMC , Veeder Root
Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing
Electronic Line Leak Detector
5/29/2017
10/17/2011
Currently in Use
3
Gasoline
15,000
Cathodically Protected Steel Fiberglass Reinforced Plastic
None None
6/1/1990
Pressurized
28
451 Yes
Ball Float Valve
Galvanic
TLS-350/Gilbarco EMC , Veeder Root
Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing
Electronic Line Leak Detector
5/29/2017
10/17/2007
Report Generation Date: 12/12/2018 Page 665
Facility Summary in GLACIER County in the City of SAINT MARY
ST MARY LODGE
3 GOING TO THE SUN RD ST MARY LAKE
Sys Fac ID:
SAINT MARY, MT 59411 GLACIER
18-01907
Operating Permit Renewal Date: 10/20/2020
Last Inspected On: 5/11/2017
Location:
Walter Kochansky, (406) 732-4431Contact:
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
4
Gasoline
15,000
Cathodically Protected Steel Fiberglass Reinforced Plastic
None Secondary Containment Chase
6/1/1990
Pressurized
28
452 Yes
Ball Float Valve
Galvanic
TLS-350/Gilbarco EMC , Veeder Root
Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing
Electronic Line Leak Detector
5/29/2017
10/17/2007
Report Generation Date: 12/12/2018 Page 666
Facility Summary in GLACIER County in the City of SAINT MARY
SAINT MARY RANGER STATION
73 HUDSON BAY RD
Sys Fac ID:
SAINT MARY, MT 59411 GLACIER
18-02745
Operating Permit Renewal Date: 4/4/2022
Last Inspected On: 10/30/2018
Location:
John Lucke, (406) 732-7718Contact:
Owners/Operators: National Park Service, Owner/Operator DEPT OF INTERIOR73 HUDSON BAY RDBROWNING MT 59417
(406)-732-7724
Mark Hickcox, UST Class A Operator
Jeff Wysong, UST Class A Operator
Mark Hickcox, UST Class B Global Operator
Tank Id
Status
Product
Capacity
InstalledAge Tank Material of Construction Piping Material
Piping Type
Secondary Option Secondary OptionTag Number AST Spill Protected
Overfill Types
CP Met Types
ATG Type
Tank Detection Primary Pipe Detection
Secondary Pipe Detection
Catastrophic L.D. Type 3.0
Vapor Recovery
Energy Act
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Currently in Use
4
Gasoline
12,000
Cathodically Protected Steel Fiberglass Reinforced Plastic
None Double-Walled
7/1/1987
Pressurized
31
1221 Yes
Flapper Valve (Auto Shutoff)
Galvanic
TLS-350/Gilbarco EMC , Veeder Root
Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2
Electronic Line Leak Detector
12/20/2012
10/30/2018
11/3/2015
Currently in Use
6
Diesel
10,000
Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic
Double-Walled Double-Walled
10/1/2015
Safe Suction
03
5620 Yes
Flapper Valve (Auto Shutoff)
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Automatic Tank Gauging 0.2, Continuous Interstitial Monitor
Deferred
Not Required
Yes
10/28/2015