Upload
the-architects-newspaper
View
219
Download
0
Tags:
Embed Size (px)
DESCRIPTION
Facades+: Chicago 2013 Gary Flemming Powerpoint Presentation
Citation preview
Gary Flemming Window Business Manager
YKK AP America Inc.
Materials Panel
maintaining aesthetic flair while dealing with real-time issues
presented by new and aging buildings
key themes ...
Thermal Performance (reduce energy loss, lower HVAC demand)
New Construction Renovation
Daylighting (maximize DLO’s, Solar Control)
Sightlines (minimize & controlled across materials)
COST! (seeking value-rich solutions)
Ventilation (indoor air quality)
Security / Safety (access control, blast & hurricane mitigation)
Functionality (meet new tenant’s needs)
Aesthetics (modernize, historical preservation)
Operation (restore functionality)
first question ... what do you want to achieve?
Renovation ... Grand Yacht Club - Ft. Lauderdale, FL Before After
Renovation ... Punta Gorda High School Before After
Impact Resistant ADA Compliant
Historical Preservation
Aesthetics
with Geometric Shapes
New Construction ...
New Construction ... Minimized & Consistent
Sightlines
Structurally Glazed Vents designed for use with
Curtain Walls, Window Walls, or Storefronts
8 operable units (can you find them?)
New Construction ... Minimized & Consistent
Sightlines
Structurally Glazed Vents designed for use with
Curtain Walls, Window Walls, or Storefronts
maintaining aesthetic flair while dealing with real-time issues
SSG Vents
(Zero Sightline Vents) ... a cost-effective solution
Fixed over Casement Windows with Mulls Store Front with SSG Vents Cost per SF $50
Cost-effective Solution ...
Cost per SF $35
SSG Vents ... aka “Zero Sightline” Vents
SSG Vents ... aka “Zero Sightline” Vents
non-thermal vent thermally broken vent
U-factor: 0.46
CW Rating (AAMA Class)
SSG Vents ... aka “Zero Sightline” Vents
non-thermal vent thermally broken vent
U-factor: 0.41
AW Rating (AAMA Class)
Increased Surface Temperature
39° F 49° F
NFRC Thermal Modeling
maintaining aesthetic flair while dealing with real-time issues
... a few CASE STUDIES
Case Study ... Villanova University, Dougherty Hall
Original Building Circa 1955, Dining Hall addition 1964
Case Study ... Villanova University, Dougherty Hall
Case Study ... Villanova University, Dougherty Hall Before After Vents
Mill Finish U-factor: 1.19 SHGC: 0.78
Champaign Bronze, Anodized Plus®
U-factor: 0.42 SHCG: 0.22
Case Study ... Villanova University, Dougherty Hall
Champaign Bronze, Anodized Plus U-factor: 0.42 SHCG: 0.22
§ Low-E coating hides hardware § Traditional cams
§ Multipoint locks
§ Egress
§ Casement & project out vents § PO 70” x 66”
§ Uniform sight lines
§ Flexible Vent locations
Case Study ... Davis Restoration, Historical Warehouse
Steel Windows
Clear Glass
High Air Infiltration
Case Study ... Davis Restoration, Historical Warehouse Before
After
U-factor: 0 .46
SHGC: 0.24
Case Study ... Davis Restoration, Historical Warehouse
U-factor: 1.19
SHGC: 0.82
Before After
§ Storefront w/SSG Vent replacement for steel windows
§ Small uniform sightlines
§ Grid looks similar to original
§ Cost per SF $37/SF (23% lower than window solution)
§ System can Span 10’+ (window systems typically span 7’)
§ Tested vent size 70” x 60”
§ Improved Thermal Performance
Davis Restoration, Historical Warehouse Case Study ... Window Solution Storefront Zero Sightline Solution
maintaining aesthetic flair while dealing with real-time issues
Hung Windows w/ Panning ... a cost-effective solution
Case Study ... Lee High School, Campus Renovation
A mix of new construction, renovation, and code compliance
Case Study ... Lee High School, Campus Renovation
1st renovation completed in the 1980’s
Original & New Openings
Wood deterioration was evident. Replaced with concrete and double wood buck.
Full length Sill starter w/ end dam and tied to jamb for enhanced waterproofing
Case Study ... Lee High School, Campus Renovation
Case Study ... Lee High School, Campus Renovation
Primary Sealant Support Mulls Sill Starter Post-set Colonial Panning
Case Study ... Lee High School, Campus Renovation
Post renovation: maintains historic look, complies with new codes
maintaining aesthetic flair while dealing with real-time issues
Advanced Thermal Performance ... product evolution continues
Thermal Barrier
Wide Thermal Barrier
Air Tight
Gasket
Traditional Method YOW 350 T
Advanced Method YOW 350 XT
Product Evolution... 3 ½” Window System
Traditional Method YOW 350 T
Advanced Method YOW 350 XT
Product Evolution... 3 ½” Window System
37° F 62° F
NFRC Thermal Modeling
maintaining aesthetic flair while dealing with real-time issues
... supported by YKK AP America