S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AS T A N D ‘ N S E A M ®

• A high-performance, structural standing seam roof system for the most demanding application

• Test reports confirm that Stand ‘N Seam has the highest wind uplift resistance of any standing seam panel available on the market

• Unique one-piece stainless steel clip design does not fold into side joint of panel, allowing unrestricted thermal movement

• Side joints are double lock-seamed with an electric seaming machine, ensuring weathertightness

• Factory or field-forming by a portable roll-former provides continuous long-length panels from ridge to eave and eliminates unsightly end-laps. Field forming available only by qualified Fabral operators

• Factory applied sealant is standard

• ASTM E1592 and Multiple UL90 ratings in both steel and aluminum for applications over open framing or solid substances

• Fully tested performance for air and water infiltration

• Multiple UL fire resistant assemblies available

• Miami Dade County tested and approved in aluminum and steel

• UL Class A fire rated

• Class 4 impact rating

• .032" and .040" aluminum and 24 gauge and 22 gauge steel and copper are available

21/2" 21/4"

STAND'N SEAM

21/4"21/2"

12" or 16"

Wind Uplift

UL90 #275, 275A, 275B

UL2218 Class 4 impact

ASTM E330/ASTM E1592 24 ga allowable load of 69.70 psf @ 5'

24 ga allowable load of 95.76 psf @ 2.5'

22 ga allowable load of 87.88 psf @ 5'

.032" AL allowable load of 48.48 psf @ 5'

.032" AL allowable load of 66.67 psf @ 2.5'

.040" AL allowable load of 66.67 psf @ 5'

.040" AL allowable load of 82.42 psf @ 2.5'

MIAMI DADE NOA 05-0405.02 (steel) 06-0307.03 (aluminum)

Air Infiltration

ASTM E283 .006 @20 psf

ASTM E1680 0.00 @ 20 psf

Water Penetration

ASTM E331 no water @ 20 psf

ASTM E1646 no water @ 20 psf

Minimum Roof Slope

1/2:12

Available Widths

12" and 16"

Standard Lengths

6' to 47' (field forming available for 16" panel only)

21/2" 21/4"

STAND'N SEAM

21/4"21/2"

12" or 16"

21/2" 21/4"

STAND'N SEAM

21/4"21/2"

12" or 16"

3

Page 3: FABRAL ARCHITECTURAL SYSTEMS · ASTM E331 no water @ 20 psf ASTM E1546 no water @ 20 psf Minimum Roof Slope 1/2:12 Standard Lengths 6' to 51' 7. STANDING SEAM ROOF PANELS TECHNICAL

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AT H I N S E A M

• Engineered snap-together high-performance panel

• Widely specified classic thin seam design

• Panel legs continuously interlock together, not just to the clip, for added strength

• Multiple wind uplift tests including ASTM E1592 and UL90

• Factory applied seam sealant is standard

• Shadow lines are included on standard panel profile

• Optional panel shapes include stiffening ribs, striations or smooth panel pans

• Can be installed over open framing or solid substrates

• Concealed clips provide unlimited thermal movement

• Factory or field forming by a portable roll-former provides continuous long-length panels from ridge to eave and eliminates unsightly end laps. Field forming available only by qualified Fabral operators

• Available with batten for bolder seam lines

• Tapered panel available

• .032" and .040" aluminum and 24 gauge and 22 gauge steel and copper are available

12", 16" or 18" COVERAGE

1 3/

4"

THIN SEAM

Wind Uplift

UL90 #303, 359, 359A, 343, 417

ASTM E1592 22 ga allowable load of 40.61 psf @ 5'

22 ga allowable load of 48.48 psf @ 2.5'

24 ga allowable load of 29.70 psf @ 5'

24 ga allowable load of 30.30 psf @ 2.5'

Air Infiltration

ASTM E283 .009 @ 6.24 psf

Water Penetration

ASTM E331 no water @ 15 psf

Minimum Roof Slope

1:12

Available Widths

12", 16" and 18"

Standard Lengths

6' to 47' (field forming available)

12", 16" or 18" COVERAGE

1 3/4"

THIN SEAM

4

Page 4: FABRAL ARCHITECTURAL SYSTEMS · ASTM E331 no water @ 20 psf ASTM E1546 no water @ 20 psf Minimum Roof Slope 1/2:12 Standard Lengths 6' to 51' 7. STANDING SEAM ROOF PANELS TECHNICAL

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AS L I M S E A M

• An economical, high-performance standing seam design

• Unique one-piece stainless steel clip allows for unlimited thermal movement and reduced panel pan uplift under negative load

• Panel legs continuously interlock together, not just to the clip

• Multiple wind uplift tests including ASTM E1592, UL60 (aluminum) and UL90 (steel) ratings

• Factory applied seam sealant is standard

• Usually installed over a solid substrate, but can be installed over open framing at a 3' maximum on center spacing

• UL Class A fire rated

• Class 4 impact rated

• .032" and .040" aluminum and 24 gauge and 22 gauge steel and copper are available

• Shadowlines are available

12" or 16" COVERAGE1 1/2"

1 1/2"

slim seam

Wind Uplift

UL90 #274, 274A, 369

UL2218 Class 4 impact

ASTM E1592 24 ga allowable load of 48.48 psf @ 2.5'

Air Infiltration

ASTM E283 .09 @ 1.57 psf

ASTM E1680 0.00 @ 20 psf

Water Penetration

ASTM E331 no water @ 25 psf

ASTM E1646 no water @ 12 psf

Minimum Roof Slope

1:12

Available Widths

12" and 16"

Standard Lengths

6' to 47' 12" or 16" COVERAGE

1 1/2"

1 1/2"

slim seam

5

Page 5: FABRAL ARCHITECTURAL SYSTEMS · ASTM E331 no water @ 20 psf ASTM E1546 no water @ 20 psf Minimum Roof Slope 1/2:12 Standard Lengths 6' to 51' 7. STANDING SEAM ROOF PANELS TECHNICAL

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AP R E S T I G E ( f o r m e r l y A m p - L o k )

• Mechanical seamed structural standing seam panel

• 90 and 180 degree seaming available

• Concealed two-piece panel clip allows for thermal expansion

• Multiple wind uplift tests including FM, ASTM E1592 and UL90

• Factory applied seam sealant is standard

• Shadow lines are included on standard panel profile

• Optional panel shapes include stiffening ribs or smooth panel pans

• Can be installed over open framing or solid substrates

• Curved panels are available to a 10' minimum radius

• Tapered panels available

• Factory or field forming by a portable roll-former provides continuous long-length panels from ridge to eave and eliminates unsightly end laps. Field forming available only by qualified Fabral operators

• 24 gauge and 22 gauge steel are available

16"

2"

PRESTIGE

Wind Uplift

UL90 #90, 176, 180, 238, 548, 549

ASTM E1592 Single Lock:

24 ga 18" allowable load of 35.15 @ 5'

24 ga 18" allowable load of 29.09 @ 2.5'

Double Lock:

24 ga 18" allowable load of 58.79 @ 5'

24 ga 18" allowable load of 67.88 @ 2.5'

Factory Mutual FM Class I-90 tested and approved

Air Infiltration

ASTM E283 .01 @ 15 psf

Water Penetration

ASTM E331 no water @ 6.24 psf

Minimum Roof Slope

1:12

Available Widths

12", 16" and 18"

Standard Lengths

6' to 47' (field forming available)

16.000

2.000

PRESTIGE

16.000

2.000

PRESTIGE

6

Page 6: FABRAL ARCHITECTURAL SYSTEMS · ASTM E331 no water @ 20 psf ASTM E1546 no water @ 20 psf Minimum Roof Slope 1/2:12 Standard Lengths 6' to 51' 7. STANDING SEAM ROOF PANELS TECHNICAL

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AT - R I B ®

• Symmetrical design allows ease of installation for difficult hip, ridge and valley condition

• Mechanically-seamed cap strip with factory-applied sealant tape assures a weather-tight seam

• One-piece concealed clip allows for thermal movement

• Panels can be tapered

• Multiple UL90 ratings for steel panels

• Can be installed over open framing or solid substrate

• Factory or field forming by a portable roll-former provides continuous long-length panels from ridge to eave and eliminates unsightly end laps. Field forming available only by qualified Fabral operators

• UL Class A fire rated

• .032" and .040" aluminum and 24 gauge and 22 gauge steel are available

12", 16", & 18" COVERAGE

1 1/2"

2 3/8" 1/16" x 1" RIBS STANDARD

FACTORY APPLIED SEALANT TAPE

T-RIB

Wind Uplift

UL90 #103, 139, 415, 416

ASTM E1592 24 ga allowable load of 18.9 @ 5'

24 ga allowable load of 36.36 @ 2.5'

.040 allowable load of 23.6 @ 5'

Air Infiltration

ASTM E283 .015 @ 6.24 psf

Water Penetration

ASTM E331 no water @ 6.24 psf

Minimum Roof Slope

1/2:12

Available Widths

12", 16" and 18"

Standard Lengths

6' to 47' (field forming available)

2 1 / 2 " S S R

• Classic style with narrow batten seams

• Designed for durability against rain, snow and wind

• Concealed clip fastening system

• Easy installation

• May be disassembled without damaging panels or caps

• .032" and .040" aluminum and 24 gauge and 22 gauge steel are available

• Heavier gauges available (18 ga, 20 ga)

18" COVERAGE

4 15/16" 6" 4 15/16"

2 7/16"

21/2 SSR Clip

12", 16", & 18" COVERAGE

1 1/2"

2 3/8" 1/16" x 1" RIBS STANDARD

FACTORY APPLIED SEALANT TAPE

T-RIB

18" COVERAGE

4 15/16" 6" 4 15/16"

2 7/16"

21/2 SSR Clip

Wind Uplift

UL90 #190, 190B

Air Infiltration

ASTM E283 .00 @ 20 psf

ASTM E1680 .019 @ 20 psf

Water Penetration

ASTM E331 no water @ 20 psf

ASTM E1546 no water @ 20 psf

Minimum Roof Slope

1/2:12

Standard Lengths

6' to 51'

7

Page 7: FABRAL ARCHITECTURAL SYSTEMS · ASTM E331 no water @ 20 psf ASTM E1546 no water @ 20 psf Minimum Roof Slope 1/2:12 Standard Lengths 6' to 51' 7. STANDING SEAM ROOF PANELS TECHNICAL

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AS N A P - O N - S E A M

• Classic snap-on-seam two-component design

• 1" nominal seam height using a 1" seam cover

• Allows for easy removal of individual panels for repairs

• Concealed clip allows for unlimited thermal movement

• Panel can be curved to a minimum 5'–0" radius

• Must be installed over a solid substrate

• Panels can be tapered

• Easy to install

• .032" and .040" aluminum and 24 gauge and 22 gauge steel are available

12", 16", 18", or 20"

1"

3/8"

1 3/4"

3/8"

7/8"

PAN

CAP

1" SEAM WITH CAP AND CLIP 1 3/4" SEAM WITH CAP AND CLIP

3/8"

1"

SNAP-ON-SEAM

R1/16"

3/4"

Wind Uplift

ASTM E1592 24 ga allowable load of 59.39 @ 1'–3"

24 ga alllowable load of 42.42 @ 2'–6"

Minimum Roof Slope

3:12

Available Widths

12", 16", 18" and 20"

Standard Lengths

Panels 6' to 47'

Battens 6' to 30'

S N A P - O N - B A T T E N

• Classic snap-on wide batten design providing bold aesthetic design

• Ideal for mansards with a slope transition to vertical fascia

• Easy to install and perform knuckle joint detail

• Concealed clip allows for unlimited thermal movement

• Must be installed over a solid substrate

• Panels can be tapered with limitations due to batten width

• .032" and .040" aluminum and 24 gauge and 22 gauge steel are available

11 1/8"

1 1/2"

1 9/16"

1 7/8"

1 9/16"

1 7/8"

FOR 12" COVERAGE(SIMILARLY FOR OTHER WIDTH PANELS)

CAP SEAM WITH CAP AND CLIP

PAN

SNAP-ON-BATTEN

Minimum Roof Slope

3:12

Available Widths

12", 16", 18" and 20"

Standard Lengths

Panels 6' to 47'

Battens 6' to 30'

12", 16", 18", or 20"

1"

3/8"

1 3/4"

3/8"

7/8"

PAN

CAP

1" SEAM WITH CAP AND CLIP 1 3/4" SEAM WITH CAP AND CLIP

3/8"

1"

SNAP-ON-SEAM

R1/16"

3/4"

12", 16", 18", or 20"

1"

3/8"

1 3/4"

3/8"

7/8"

PAN

CAP

1" SEAM WITH CAP AND CLIP 1 3/4" SEAM WITH CAP AND CLIP

3/8"

1"

SNAP-ON-SEAM

R1/16"

3/4"

11 1/8"

1 1/2"

1 9/16"

1 7/8"

1 9/16"

1 7/8"

FOR 12" COVERAGE(SIMILARLY FOR OTHER WIDTH PANELS)

CAP SEAM WITH CAP AND CLIP

PAN

SNAP-ON-BATTEN

11 1/8"

1 1/2"

1 9/16"

1 7/8"

1 9/16"

1 7/8"

FOR 12" COVERAGE(SIMILARLY FOR OTHER WIDTH PANELS)

CAP SEAM WITH CAP AND CLIP

PAN

SNAP-ON-BATTEN

9

Page 8: FABRAL ARCHITECTURAL SYSTEMS · ASTM E331 no water @ 20 psf ASTM E1546 no water @ 20 psf Minimum Roof Slope 1/2:12 Standard Lengths 6' to 51' 7. STANDING SEAM ROOF PANELS TECHNICAL

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AS N A P - O N - S E A M H I G H P R O F I L E

• High profile snap-on-seam

• 1 3/4" nominal seam height using a 1" seam cover

• Non-integral two piece construction

• Allows for easy removal of individual panels for repairs

• Concealed clip allows for thermal movement

• Panels can be tapered

• Easy to install

• UL Class A fire rated

• .032" and .040" aluminum and 24 gauge and 22 gauge steel are available

12", 16", 18", or 20"

1"

3/8"

1 3/4"

3/8"

7/8"

PAN

CAP

1" SEAM WITH CAP AND CLIP 1 3/4" SEAM WITH CAP AND CLIP

3/8"

1 3/4"

SNAP-ON-SEAM

R1/16"

1 1/2"

Minimum Roof Slope

3:12

Available Widths

12", 16", 18" and 20"

Standard Lengths

Panels 6' to 47'

Battens 6' to 30'

H I G H S E A M

• Economical snap-together standing seam panel

• Non-structural design must be installed over solid substrate

• 1 1/2" nominal seam height

• Concealed clip allows for thermal movement

• UL90 rated over plywood

• Easy installation

• Panels can be tapered

• .032" aluminum and 24 gauge steel are available

1" SHADOWLINES AVAILABLE

12", 16", 18" & 20" COVERAGE

1 1/

2"

HIGH SEAM

Wind Uplift

UL90 #370

Minimum Roof Slope

2:12

Available Widths

12", 16", 18" and 20"

Standard Lengths

6' to 47'

PANEL OPTIONSMOOTH

1.100

18.000

1.500

HIGH SEAM

12", 16", 18", or 20"

1"

3/8"

1 3/4"

3/8"

7/8"

PAN

CAP

1" SEAM WITH CAP AND CLIP 1 3/4" SEAM WITH CAP AND CLIP

3/8"

1 3/4"

SNAP-ON-SEAM

R1/16"

1 1/2"

12", 16", 18", or 20"

1"

3/8"

1 3/4"

3/8"

7/8"

PAN

CAP

1" SEAM WITH CAP AND CLIP 1 3/4" SEAM WITH CAP AND CLIP

3/8"

1"

SNAP-ON-SEAM

R1/16"

3/4"

10

Page 9: FABRAL ARCHITECTURAL SYSTEMS · ASTM E331 no water @ 20 psf ASTM E1546 no water @ 20 psf Minimum Roof Slope 1/2:12 Standard Lengths 6' to 51' 7. STANDING SEAM ROOF PANELS TECHNICAL

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AG R A N D C U R V E

• Engineered for durability and flexibility

• Narrow seam cover provides contemporary aesthetics

• 1 11/16" seam cover provides a bolder shadow line

• Seam cover continuously interlock to panel pan

• Available in steel, aluminum and copper substrates

• Clips provide unlimited thermal movement

• Panels can be curved to a minimum 15'–0" radius

• Factory or field forming by a portable roll-former provides continuous long-length panels from ridge to eave and eliminates unsightly end laps. Field forming available only by qualified Fabral operators

• .032" aluminum and 24 gauge steel are available

12" COVERAGE

16" COVERAGE

11/16"

1 11/16"

5"1"

1"

Grand Curve N

G R A N D B A T T E N

• Engineered for durability and flexibility

• Wide batten caps add a bold architectural aesthetic to roof lines

• Battens continuously interlock to panel pan

• Available in steel, aluminum and copper substrates

• Clips provide unlimited thermal movement

• Factory or field forming by a portable roll-former provides continuous long-length panels from ridge to eave and eliminates unsightly end laps. Field forming available only by qualified Fabral operators

• .032" aluminum and 24 gauge steel are available

2 1/4"

2"

18" COVERAGE

24" COVERAGE

5"1"

7"1"

Grand Curve W

Wind Uplift

ASTM E1592 24 ga allowable load of 32.12 psf @ 1'–3"

24 ga allowable load of 21.21 psf @ 3'–9"

Minimum Roof Slope

3:12

Available Widths

12", 16", 18" and 24"

Standard Lengths

Factory Formed 6' to 51' (field forming available)

12" COVERAGE

16" COVERAGE

11/16"

1 11/16"

5"1"

1"

Grand Curve N

2 1/4"

2"

18" COVERAGE

24" COVERAGE

5"1"

7"1"

Grand Curve W

Wind Uplift

UL90 #585

ASTM E1592 24 ga allowable load of 52.12 psf @ 1'–3"

24 ga allowable load of 33.33 psf @ 3'–9"

Minimum Roof Slope

3:12

Available Widths

12", 16" and 18"

Standard Lengths

Factory Formed 6' to 51' (field forming available)

11

Page 10: FABRAL ARCHITECTURAL SYSTEMS · ASTM E331 no water @ 20 psf ASTM E1546 no water @ 20 psf Minimum Roof Slope 1/2:12 Standard Lengths 6' to 51' 7. STANDING SEAM ROOF PANELS TECHNICAL

E X P O S E D - F A S T E N E R P A N E L S

T E C H N I C A L D A T AH E F T I - R I B ®

• 7.2" rib pitch allows best strength-to-weight ratio available

• Excellent for both wall and roof applications

• Diaphragm capacity per ICBO Evaluation Report

• Mitered corners are available

• May be used in vertical or horizontal orientation

• Available curved

• Class 4 impact rating

• Class A fire rating

• .032", .040" and .050" aluminum and 26, 24, 22, 20 and 18 gauge steel are available

36"

CL LC

PAINTED SIDE

A. HEFTI PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"

* OPTIONAL

7.2"

HEFTI

1 1/

2"

Wind Uplift

UL90 #244

Air Infiltration

ASTM E283 0.0 @ 20 psf

Water Penetration

ASTM E331 no water @ 20 psf

Minimum Roof Slope

2:12

Available Width

36"

Standard Lengths

6' to 45'

36"

CL LC

PAINTED SIDE

A. HEFTI PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"

* OPTIONAL

7.2"

HEFTI

1 1/

2"

21

H R - 2 8 8

• Lighter gauge commercial and industrial wall or long span roofing panel

• Ideal for Carports, Walkway Canopies and Eyebrow Canopies

• Material: Silconized Modified Polyester painted GALVALUME® AZ-50 (Aluminum-Zinc Coated Steel) and Mill Finished GALVALUME® Plus AZ-55

• 28.8" coverage based on a 43" coil feed

• May be used in vertical or horizontal orientation

• 26 gauge steel is available

1 1/

2"

H.R 288 PANEL

28 4/5" COVERAGE

7.2"

Minimum Roof Slope

2:12

Available Width

28.8"

Standard Lengths

6' to 45'

1 1/2"

H.R 288 PANEL

28 4/5" COVERAGE

7.2"

Page 11: FABRAL ARCHITECTURAL SYSTEMS · ASTM E331 no water @ 20 psf ASTM E1546 no water @ 20 psf Minimum Roof Slope 1/2:12 Standard Lengths 6' to 51' 7. STANDING SEAM ROOF PANELS TECHNICAL

E X P O S E D - F A S T E N E R P A N E L S

T E C H N I C A L D A T AU LT R A R I B ®

• Original true 1 1/2" high multi-rib panel

• Purlin bearing leg ensures proper attachment and lap engagement

• Ideal for commercial and industrial applications

• Aluminum available on an inquiry basis

• May be used in vertical or horizontal orientation

• Class 4 impact rating

• Class A fire rating

• .032" aluminum or 26, 24 and 22 gauge steel are available

38" OVERALL

12"

1 1/2"

36" COVERAGE

ultra rib

Wind Uplift

UL90 #168

Minimum Roof Slope

1:12

Available Width

36"

Standard Lengths

6' to 40'

4 " R I B

• An industry standard — ideal for heavy industrial and lagging applications

• Available in mill finish, alclad or painted

• 8" rib available on inquiry basis

• May be used in vertical or horizontal orientation

• Available in .032", .040" and .050" aluminum in various widths

• Available in 24, 22, and 20 gauge steel in various widths

35 9/16"

32"

1"

4" RIB

Standard Available Width

32" (painted aluminum is 36"; unpainted aluminum is 44")

Standard Lengths

6' to 45'

35 9/16"

32"

1"

4" RIB

38" OVERALL

12"

1 1/2"

36" COVERAGE

ultra rib

22

Page 12: FABRAL ARCHITECTURAL SYSTEMS · ASTM E331 no water @ 20 psf ASTM E1546 no water @ 20 psf Minimum Roof Slope 1/2:12 Standard Lengths 6' to 51' 7. STANDING SEAM ROOF PANELS TECHNICAL

E X P O S E D - F A S T E N E R P A N E L S

T E C H N I C A L D A T AV - B E A M

• Excellent strength and spanning capability

• Diaphragm capacity per ICBO Evaluation Report

• May be used in vertical or horizontal orientation

• Mitered corners are available

• Available in .032", .040" and .050" aluminum in various widths

• Available in 24, 22, and 20 gauge steel in various widths

32" COVERAGE

1 3/4"

33 7/8" OVERALL

Minimum Roof Slope

2:12

Standard Available Width

32" (painted aluminum is 32"; unpainted aluminum is 42 2/3")

Standard Lengths

6' to 45'

32" Coverage

1 3/4"

33 7/8" OVERALL

23

Page 13: FABRAL ARCHITECTURAL SYSTEMS · ASTM E331 no water @ 20 psf ASTM E1546 no water @ 20 psf Minimum Roof Slope 1/2:12 Standard Lengths 6' to 51' 7. STANDING SEAM ROOF PANELS TECHNICAL

E X P O S E D - F A S T E N E R P A N E L S

T E C H N I C A L D A T A1 / 2 " C O R R U G A T E D

• An economical and versatile wall or roof panel

• Can be perforated for acoustical applications

• Standard 13.3% open area (1/8" diameter holes on .325" staggered centers)

• May be used in vertical or horizontal orientation

• Mitered corners are available

• Available curved

• Class 4 impact rating

• Class A fire rating

• .032", .040" and .050" aluminum are available in various widths

• 26, 24, 22, 20 and 18 gauge steel are available in various widths

OVERALL VARIES

COVERAGE VARIES

1/2"

1/2" CORRUGATED

2.667"

Minimum Roof Slope

2 1/2:12

Standard Lengths

6' to 45'

7 / 8 " C O R R U G A T E D

• Bolder look

• Great for exterior and interior uses

• Can be perforated for acoustical applications

• Standard 13.3% open area (1/8" diameter holes on .325" staggered centers)

• May be used in vertical or horizontal orientation

• Mitered corners are available

• Available curved

• .032", .040" and .050" aluminum are available in various widths

• 26, 24, 22, 20 and 18 gauge steel are available in various widths

PAINTED SIDE 7/8"

7/8" CORRUGATED

32"

2.667"

Minimum Roof Slope

2 1/2:12

Standard Lengths

6' to 45'

OVERALL VARIES

COVERAGE VARIES

1/2"

1/2" CORRUGATED

PAINTED SIDE

A. 7/8" CORRUGATEDB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"

* OPTIONAL

7/8"

7/8" CORRUGATED

32"

2.667"

25

Page 14: FABRAL ARCHITECTURAL SYSTEMS · ASTM E331 no water @ 20 psf ASTM E1546 no water @ 20 psf Minimum Roof Slope 1/2:12 Standard Lengths 6' to 51' 7. STANDING SEAM ROOF PANELS TECHNICAL

E X P O S E D - F A S T E N E R P A N E L S

T E C H N I C A L D A T AD E E P R I B I I

• Can be used for both wall and roof applications

• May be used in vertical or horizontal orientation

• Mitered corners are available

• .032", .040" and .050" aluminum are available in various widths

• 22, 20 and 18 gauge steel are available in various widths

DEEP RIB II (ALUMINUM)

2"

40"44 1/2"

33 3/4" OVERALL

30" COVERAGE

DEEP RIB II (STEEL)

2"

ALL DIMENSIONS ARE CENTERLINE DIMENSIONS.

OVERLAP CORRUGATION

OVERLAP CORRUGATION

Minimum Roof Slope (when inverted as roof )

1:12

Available Widths

30" and 40"

Standard Lengths

6' to 45'

D E E P R I B I V

• A bold rib design, ideal for horizontal and vertical applications

• 4" deep ribs provide excellent strength and spanning capacity

• Can be used for both wall and roofs (inverted for roof)

• Excellent for applications with large spans between structural framing members

• May be used in vertical or horizontal orientation

• Mitered corners are available

• Available curved

• .032", .040" and .050" aluminum and 22, 20 and 18 gauge steel are available

12"

24" COVERAGE

25 1/4" OVERALL

4"

12"

25 1/4" OVERALL

24" COVERAGE

4"

DEEP RIB 4

Roofing

Siding

Minimum Roof Slope

1:12

Available Width

24"

Standard Lengths

6' to 45'

DEEP RIB II (ALUMINUM)

2"

3'-4"

3'-81/2"

33-7/8" OVERALL

30" COVERAGE

DEEP RIB II (STEEL)

2"

ALL DIMENSIONS ARE CENTERLINE DIMENSIONS.

OVERLAP CORRUGATION

OVERLAP CORRUGATION

12"

24" COVERAGE

25 1/4" OVERALL

4"

12"

25 1/4" OVERALL

24" COVERAGE

4"

DEEP RIB 4

Roofing

Siding

12"

24" COVERAGE

25 1/4" OVERALL

4"

12"

25 1/4" OVERALL

24" COVERAGE

4"

DEEP RIB 4

Roofing

Siding

26

Page 15: FABRAL ARCHITECTURAL SYSTEMS · ASTM E331 no water @ 20 psf ASTM E1546 no water @ 20 psf Minimum Roof Slope 1/2:12 Standard Lengths 6' to 51' 7. STANDING SEAM ROOF PANELS TECHNICAL

E X P O S E D - F A S T E N E R P A N E L S

T E C H N I C A L D A T A

R - P A N E L

• Economic commercial and industrial wall panel

• Ideal for metal buildings, light commercial structures and modular buildings

• Material: Polyester painted GALVALUME® AZ-50 (Aluminum-Zinc Coated Steel) and Mill Finished GALVALUME® Plus AZ-55

• Full 36" net coverage based on a 41.5625" coil feed

• 1 1/4" high major ribs on 12" center with intermediate ribs for added strength and durability

• May be used in vertical or horizontal orientation

• Panels can be reverse run for wall applications offering alternate visual aesthetics

• 26 gauge steel is available

1 1/

4"

PAINTED SIDE

36"

12" 12" 12"

"R" PANEL

Minimum Roof Slope

1:12

Available Width

36"

Standard Lengths

6' to 45'

1 1/

4"

PAINTED SIDE

36"

12" 12" 12"

"R" PANEL

27

M I G H T I - R I B ®

• Excellent commercial and industrial roof, wall or fascia requiring economic covering

• Purlin bearing leg ensures proper attachment and lap engagement

• Diaphragm capacity per ICBO Evaluation Report

• UL90 rating when attached to steel purlins

• Available unpainted or finished with high-performance Enduracote® paint system in 26 gauge and PVDF in heavier gauges

• Aluminum available on an inquiry basis

• May be used in vertical or horizontal orientation

• Class 4 impact rating

• Class A fire rating

• 26 and 24 gauge available; inquire about the availability of heavier gauges

PAINTED SIDE

A. MIGHTI - RIB PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"

* OPTIONAL

36"

1 1/

4"MIGHTI - RIB PANEL

12"12"12"

Wind Uplift

UL90 #169

Factory Mutual FM Class I-90

Minimum Roof Slope

1:12

Available Width

36"

Standard Lengths

6' to 45'

PAINTED SIDE

A. MIGHTI - RIB PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"

* OPTIONAL

36"

1 1/

4"

MIGHTI - RIB PANEL

12"12"12"

Page 16: FABRAL ARCHITECTURAL SYSTEMS · ASTM E331 no water @ 20 psf ASTM E1546 no water @ 20 psf Minimum Roof Slope 1/2:12 Standard Lengths 6' to 51' 7. STANDING SEAM ROOF PANELS TECHNICAL

E X P O S E D - F A S T E N E R P A N E L S

T E C H N I C A L D A T AU - P A N E L

• Economic commercial and industrial wall panel

• Ideal for metal buildings, light commercial structures, modular buildings and mini storage interior partition walls

• Material: Polyester painted GALVALUME® AZ-50 (Aluminum-Zinc Coated Steel) and Mill Finished GALVALUME® Plus AZ-55

• 36" coverage based on a 41.5625" coil feed

• 3/4" high major ribs at 6" centers

• May be used in vertical or horizontal orientation

• 26 gauge steel is available

PAINTED SIDE

A. "U"-PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"

* OPTIONAL

13/1

6"36"

"U" PANEL

Minimum Roof Slope

2 1/2:12

Available Width

36"

Standard Lengths

3' to 45'

P B U P A N E L

• PBU is economical commercial and industrial roof and wall panel

• Purlin bearing leg ensures proper attachment and lap engagement

• Ideal for Mini Storage partition wall panels and back side parapet wall covering

• Panel can be reverse run for wall applications offering alternate visual aesthetics

• May be used in vertical or horizontal orientation

• 26 gauge steel is available

PAINTED SIDE

A. PBU-PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"

* OPTIONAL

PBU PANEL

36"

3/4"

Wind Uplift

UL90 #39, 79

Minimum Roof Slope

2 1/2:12

Available Width

36"

Standard Lengths

3' to 45'

PAINTED SIDE

A. "U"-PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"

* OPTIONAL

13/1

6"

36"

"U" PANEL

PAINTED SIDE

A. PBU-PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"

* OPTIONAL

PBU PANEL

36"

3/4"