FA
BR
AL
A
RC
HI
TE
CT
UR
AL
S
YS
TE
MS
S T A N D I N G S E A M R O O F P A N E L S
T E C H N I C A L D A T AS T A N D ‘ N S E A M ®
• A high-performance, structural standing seam roof system for the most demanding application
• Test reports confirm that Stand ‘N Seam has the highest wind uplift resistance of any standing seam panel available on the market
• Unique one-piece stainless steel clip design does not fold into side joint of panel, allowing unrestricted thermal movement
• Side joints are double lock-seamed with an electric seaming machine, ensuring weathertightness
• Factory or field-forming by a portable roll-former provides continuous long-length panels from ridge to eave and eliminates unsightly end-laps. Field forming available only by qualified Fabral operators
• Factory applied sealant is standard
• ASTM E1592 and Multiple UL90 ratings in both steel and aluminum for applications over open framing or solid substances
• Fully tested performance for air and water infiltration
• Multiple UL fire resistant assemblies available
• Miami Dade County tested and approved in aluminum and steel
• UL Class A fire rated
• Class 4 impact rating
• .032" and .040" aluminum and 24 gauge and 22 gauge steel and copper are available
21/2" 21/4"
STAND'N SEAM
21/4"21/2"
12" or 16"
Wind Uplift
UL90 #275, 275A, 275B
UL2218 Class 4 impact
ASTM E330/ASTM E1592 24 ga allowable load of 69.70 psf @ 5'
24 ga allowable load of 95.76 psf @ 2.5'
22 ga allowable load of 87.88 psf @ 5'
.032" AL allowable load of 48.48 psf @ 5'
.032" AL allowable load of 66.67 psf @ 2.5'
.040" AL allowable load of 66.67 psf @ 5'
.040" AL allowable load of 82.42 psf @ 2.5'
MIAMI DADE NOA 05-0405.02 (steel) 06-0307.03 (aluminum)
Air Infiltration
ASTM E283 .006 @20 psf
ASTM E1680 0.00 @ 20 psf
Water Penetration
ASTM E331 no water @ 20 psf
ASTM E1646 no water @ 20 psf
Minimum Roof Slope
1/2:12
Available Widths
12" and 16"
Standard Lengths
6' to 47' (field forming available for 16" panel only)
21/2" 21/4"
STAND'N SEAM
21/4"21/2"
12" or 16"
21/2" 21/4"
STAND'N SEAM
21/4"21/2"
12" or 16"
3
S T A N D I N G S E A M R O O F P A N E L S
T E C H N I C A L D A T AT H I N S E A M
• Engineered snap-together high-performance panel
• Widely specified classic thin seam design
• Panel legs continuously interlock together, not just to the clip, for added strength
• Multiple wind uplift tests including ASTM E1592 and UL90
• Factory applied seam sealant is standard
• Shadow lines are included on standard panel profile
• Optional panel shapes include stiffening ribs, striations or smooth panel pans
• Can be installed over open framing or solid substrates
• Concealed clips provide unlimited thermal movement
• Factory or field forming by a portable roll-former provides continuous long-length panels from ridge to eave and eliminates unsightly end laps. Field forming available only by qualified Fabral operators
• Available with batten for bolder seam lines
• Tapered panel available
• .032" and .040" aluminum and 24 gauge and 22 gauge steel and copper are available
12", 16" or 18" COVERAGE
1 3/
4"
THIN SEAM
Wind Uplift
UL90 #303, 359, 359A, 343, 417
ASTM E1592 22 ga allowable load of 40.61 psf @ 5'
22 ga allowable load of 48.48 psf @ 2.5'
24 ga allowable load of 29.70 psf @ 5'
24 ga allowable load of 30.30 psf @ 2.5'
Air Infiltration
ASTM E283 .009 @ 6.24 psf
Water Penetration
ASTM E331 no water @ 15 psf
Minimum Roof Slope
1:12
Available Widths
12", 16" and 18"
Standard Lengths
6' to 47' (field forming available)
12", 16" or 18" COVERAGE
1 3/4"
THIN SEAM
4
S T A N D I N G S E A M R O O F P A N E L S
T E C H N I C A L D A T AS L I M S E A M
• An economical, high-performance standing seam design
• Unique one-piece stainless steel clip allows for unlimited thermal movement and reduced panel pan uplift under negative load
• Panel legs continuously interlock together, not just to the clip
• Multiple wind uplift tests including ASTM E1592, UL60 (aluminum) and UL90 (steel) ratings
• Factory applied seam sealant is standard
• Usually installed over a solid substrate, but can be installed over open framing at a 3' maximum on center spacing
• UL Class A fire rated
• Class 4 impact rated
• .032" and .040" aluminum and 24 gauge and 22 gauge steel and copper are available
• Shadowlines are available
12" or 16" COVERAGE1 1/2"
1 1/2"
slim seam
Wind Uplift
UL90 #274, 274A, 369
UL2218 Class 4 impact
ASTM E1592 24 ga allowable load of 48.48 psf @ 2.5'
Air Infiltration
ASTM E283 .09 @ 1.57 psf
ASTM E1680 0.00 @ 20 psf
Water Penetration
ASTM E331 no water @ 25 psf
ASTM E1646 no water @ 12 psf
Minimum Roof Slope
1:12
Available Widths
12" and 16"
Standard Lengths
6' to 47' 12" or 16" COVERAGE
1 1/2"
1 1/2"
slim seam
5
S T A N D I N G S E A M R O O F P A N E L S
T E C H N I C A L D A T AP R E S T I G E ( f o r m e r l y A m p - L o k )
• Mechanical seamed structural standing seam panel
• 90 and 180 degree seaming available
• Concealed two-piece panel clip allows for thermal expansion
• Multiple wind uplift tests including FM, ASTM E1592 and UL90
• Factory applied seam sealant is standard
• Shadow lines are included on standard panel profile
• Optional panel shapes include stiffening ribs or smooth panel pans
• Can be installed over open framing or solid substrates
• Curved panels are available to a 10' minimum radius
• Tapered panels available
• Factory or field forming by a portable roll-former provides continuous long-length panels from ridge to eave and eliminates unsightly end laps. Field forming available only by qualified Fabral operators
• 24 gauge and 22 gauge steel are available
16"
2"
PRESTIGE
Wind Uplift
UL90 #90, 176, 180, 238, 548, 549
ASTM E1592 Single Lock:
24 ga 18" allowable load of 35.15 @ 5'
24 ga 18" allowable load of 29.09 @ 2.5'
Double Lock:
24 ga 18" allowable load of 58.79 @ 5'
24 ga 18" allowable load of 67.88 @ 2.5'
Factory Mutual FM Class I-90 tested and approved
Air Infiltration
ASTM E283 .01 @ 15 psf
Water Penetration
ASTM E331 no water @ 6.24 psf
Minimum Roof Slope
1:12
Available Widths
12", 16" and 18"
Standard Lengths
6' to 47' (field forming available)
16.000
2.000
PRESTIGE
16.000
2.000
PRESTIGE
6
S T A N D I N G S E A M R O O F P A N E L S
T E C H N I C A L D A T AT - R I B ®
• Symmetrical design allows ease of installation for difficult hip, ridge and valley condition
• Mechanically-seamed cap strip with factory-applied sealant tape assures a weather-tight seam
• One-piece concealed clip allows for thermal movement
• Panels can be tapered
• Multiple UL90 ratings for steel panels
• Can be installed over open framing or solid substrate
• Factory or field forming by a portable roll-former provides continuous long-length panels from ridge to eave and eliminates unsightly end laps. Field forming available only by qualified Fabral operators
• UL Class A fire rated
• .032" and .040" aluminum and 24 gauge and 22 gauge steel are available
12", 16", & 18" COVERAGE
1 1/2"
2 3/8" 1/16" x 1" RIBS STANDARD
FACTORY APPLIED SEALANT TAPE
T-RIB
Wind Uplift
UL90 #103, 139, 415, 416
ASTM E1592 24 ga allowable load of 18.9 @ 5'
24 ga allowable load of 36.36 @ 2.5'
.040 allowable load of 23.6 @ 5'
Air Infiltration
ASTM E283 .015 @ 6.24 psf
Water Penetration
ASTM E331 no water @ 6.24 psf
Minimum Roof Slope
1/2:12
Available Widths
12", 16" and 18"
Standard Lengths
6' to 47' (field forming available)
2 1 / 2 " S S R
• Classic style with narrow batten seams
• Designed for durability against rain, snow and wind
• Concealed clip fastening system
• Easy installation
• May be disassembled without damaging panels or caps
• .032" and .040" aluminum and 24 gauge and 22 gauge steel are available
• Heavier gauges available (18 ga, 20 ga)
18" COVERAGE
4 15/16" 6" 4 15/16"
2 7/16"
21/2 SSR Clip
12", 16", & 18" COVERAGE
1 1/2"
2 3/8" 1/16" x 1" RIBS STANDARD
FACTORY APPLIED SEALANT TAPE
T-RIB
18" COVERAGE
4 15/16" 6" 4 15/16"
2 7/16"
21/2 SSR Clip
Wind Uplift
UL90 #190, 190B
Air Infiltration
ASTM E283 .00 @ 20 psf
ASTM E1680 .019 @ 20 psf
Water Penetration
ASTM E331 no water @ 20 psf
ASTM E1546 no water @ 20 psf
Minimum Roof Slope
1/2:12
Standard Lengths
6' to 51'
7
S T A N D I N G S E A M R O O F P A N E L S
T E C H N I C A L D A T AS N A P - O N - S E A M
• Classic snap-on-seam two-component design
• 1" nominal seam height using a 1" seam cover
• Allows for easy removal of individual panels for repairs
• Concealed clip allows for unlimited thermal movement
• Panel can be curved to a minimum 5'–0" radius
• Must be installed over a solid substrate
• Panels can be tapered
• Easy to install
• .032" and .040" aluminum and 24 gauge and 22 gauge steel are available
12", 16", 18", or 20"
1"
3/8"
1 3/4"
3/8"
7/8"
PAN
CAP
1" SEAM WITH CAP AND CLIP 1 3/4" SEAM WITH CAP AND CLIP
3/8"
1"
SNAP-ON-SEAM
R1/16"
3/4"
Wind Uplift
ASTM E1592 24 ga allowable load of 59.39 @ 1'–3"
24 ga alllowable load of 42.42 @ 2'–6"
Minimum Roof Slope
3:12
Available Widths
12", 16", 18" and 20"
Standard Lengths
Panels 6' to 47'
Battens 6' to 30'
S N A P - O N - B A T T E N
• Classic snap-on wide batten design providing bold aesthetic design
• Ideal for mansards with a slope transition to vertical fascia
• Easy to install and perform knuckle joint detail
• Concealed clip allows for unlimited thermal movement
• Must be installed over a solid substrate
• Panels can be tapered with limitations due to batten width
• .032" and .040" aluminum and 24 gauge and 22 gauge steel are available
11 1/8"
1 1/2"
1 9/16"
1 7/8"
1 9/16"
1 7/8"
FOR 12" COVERAGE(SIMILARLY FOR OTHER WIDTH PANELS)
CAP SEAM WITH CAP AND CLIP
PAN
SNAP-ON-BATTEN
Minimum Roof Slope
3:12
Available Widths
12", 16", 18" and 20"
Standard Lengths
Panels 6' to 47'
Battens 6' to 30'
12", 16", 18", or 20"
1"
3/8"
1 3/4"
3/8"
7/8"
PAN
CAP
1" SEAM WITH CAP AND CLIP 1 3/4" SEAM WITH CAP AND CLIP
3/8"
1"
SNAP-ON-SEAM
R1/16"
3/4"
12", 16", 18", or 20"
1"
3/8"
1 3/4"
3/8"
7/8"
PAN
CAP
1" SEAM WITH CAP AND CLIP 1 3/4" SEAM WITH CAP AND CLIP
3/8"
1"
SNAP-ON-SEAM
R1/16"
3/4"
11 1/8"
1 1/2"
1 9/16"
1 7/8"
1 9/16"
1 7/8"
FOR 12" COVERAGE(SIMILARLY FOR OTHER WIDTH PANELS)
CAP SEAM WITH CAP AND CLIP
PAN
SNAP-ON-BATTEN
11 1/8"
1 1/2"
1 9/16"
1 7/8"
1 9/16"
1 7/8"
FOR 12" COVERAGE(SIMILARLY FOR OTHER WIDTH PANELS)
CAP SEAM WITH CAP AND CLIP
PAN
SNAP-ON-BATTEN
9
S T A N D I N G S E A M R O O F P A N E L S
T E C H N I C A L D A T AS N A P - O N - S E A M H I G H P R O F I L E
• High profile snap-on-seam
• 1 3/4" nominal seam height using a 1" seam cover
• Non-integral two piece construction
• Allows for easy removal of individual panels for repairs
• Concealed clip allows for thermal movement
• Panels can be tapered
• Easy to install
• UL Class A fire rated
• .032" and .040" aluminum and 24 gauge and 22 gauge steel are available
12", 16", 18", or 20"
1"
3/8"
1 3/4"
3/8"
7/8"
PAN
CAP
1" SEAM WITH CAP AND CLIP 1 3/4" SEAM WITH CAP AND CLIP
3/8"
1 3/4"
SNAP-ON-SEAM
R1/16"
1 1/2"
Minimum Roof Slope
3:12
Available Widths
12", 16", 18" and 20"
Standard Lengths
Panels 6' to 47'
Battens 6' to 30'
H I G H S E A M
• Economical snap-together standing seam panel
• Non-structural design must be installed over solid substrate
• 1 1/2" nominal seam height
• Concealed clip allows for thermal movement
• UL90 rated over plywood
• Easy installation
• Panels can be tapered
• .032" aluminum and 24 gauge steel are available
1" SHADOWLINES AVAILABLE
12", 16", 18" & 20" COVERAGE
1 1/
2"
HIGH SEAM
Wind Uplift
UL90 #370
Minimum Roof Slope
2:12
Available Widths
12", 16", 18" and 20"
Standard Lengths
6' to 47'
PANEL OPTIONSMOOTH
1.100
18.000
1.500
HIGH SEAM
12", 16", 18", or 20"
1"
3/8"
1 3/4"
3/8"
7/8"
PAN
CAP
1" SEAM WITH CAP AND CLIP 1 3/4" SEAM WITH CAP AND CLIP
3/8"
1 3/4"
SNAP-ON-SEAM
R1/16"
1 1/2"
12", 16", 18", or 20"
1"
3/8"
1 3/4"
3/8"
7/8"
PAN
CAP
1" SEAM WITH CAP AND CLIP 1 3/4" SEAM WITH CAP AND CLIP
3/8"
1"
SNAP-ON-SEAM
R1/16"
3/4"
10
S T A N D I N G S E A M R O O F P A N E L S
T E C H N I C A L D A T AG R A N D C U R V E
• Engineered for durability and flexibility
• Narrow seam cover provides contemporary aesthetics
• 1 11/16" seam cover provides a bolder shadow line
• Seam cover continuously interlock to panel pan
• Available in steel, aluminum and copper substrates
• Clips provide unlimited thermal movement
• Panels can be curved to a minimum 15'–0" radius
• Factory or field forming by a portable roll-former provides continuous long-length panels from ridge to eave and eliminates unsightly end laps. Field forming available only by qualified Fabral operators
• .032" aluminum and 24 gauge steel are available
12" COVERAGE
16" COVERAGE
11/16"
1 11/16"
5"1"
1"
Grand Curve N
G R A N D B A T T E N
• Engineered for durability and flexibility
• Wide batten caps add a bold architectural aesthetic to roof lines
• Battens continuously interlock to panel pan
• Available in steel, aluminum and copper substrates
• Clips provide unlimited thermal movement
• Factory or field forming by a portable roll-former provides continuous long-length panels from ridge to eave and eliminates unsightly end laps. Field forming available only by qualified Fabral operators
• .032" aluminum and 24 gauge steel are available
2 1/4"
2"
18" COVERAGE
24" COVERAGE
5"1"
7"1"
Grand Curve W
Wind Uplift
ASTM E1592 24 ga allowable load of 32.12 psf @ 1'–3"
24 ga allowable load of 21.21 psf @ 3'–9"
Minimum Roof Slope
3:12
Available Widths
12", 16", 18" and 24"
Standard Lengths
Factory Formed 6' to 51' (field forming available)
12" COVERAGE
16" COVERAGE
11/16"
1 11/16"
5"1"
1"
Grand Curve N
2 1/4"
2"
18" COVERAGE
24" COVERAGE
5"1"
7"1"
Grand Curve W
Wind Uplift
UL90 #585
ASTM E1592 24 ga allowable load of 52.12 psf @ 1'–3"
24 ga allowable load of 33.33 psf @ 3'–9"
Minimum Roof Slope
3:12
Available Widths
12", 16" and 18"
Standard Lengths
Factory Formed 6' to 51' (field forming available)
11
E X P O S E D - F A S T E N E R P A N E L S
T E C H N I C A L D A T AH E F T I - R I B ®
• 7.2" rib pitch allows best strength-to-weight ratio available
• Excellent for both wall and roof applications
• Diaphragm capacity per ICBO Evaluation Report
• Mitered corners are available
• May be used in vertical or horizontal orientation
• Available curved
• Class 4 impact rating
• Class A fire rating
• .032", .040" and .050" aluminum and 26, 24, 22, 20 and 18 gauge steel are available
36"
CL LC
PAINTED SIDE
A. HEFTI PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"
* OPTIONAL
7.2"
HEFTI
1 1/
2"
Wind Uplift
UL90 #244
Air Infiltration
ASTM E283 0.0 @ 20 psf
Water Penetration
ASTM E331 no water @ 20 psf
Minimum Roof Slope
2:12
Available Width
36"
Standard Lengths
6' to 45'
36"
CL LC
PAINTED SIDE
A. HEFTI PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"
* OPTIONAL
7.2"
HEFTI
1 1/
2"
21
H R - 2 8 8
• Lighter gauge commercial and industrial wall or long span roofing panel
• Ideal for Carports, Walkway Canopies and Eyebrow Canopies
• Material: Silconized Modified Polyester painted GALVALUME® AZ-50 (Aluminum-Zinc Coated Steel) and Mill Finished GALVALUME® Plus AZ-55
• 28.8" coverage based on a 43" coil feed
• May be used in vertical or horizontal orientation
• 26 gauge steel is available
1 1/
2"
H.R 288 PANEL
28 4/5" COVERAGE
7.2"
Minimum Roof Slope
2:12
Available Width
28.8"
Standard Lengths
6' to 45'
1 1/2"
H.R 288 PANEL
28 4/5" COVERAGE
7.2"
E X P O S E D - F A S T E N E R P A N E L S
T E C H N I C A L D A T AU LT R A R I B ®
• Original true 1 1/2" high multi-rib panel
• Purlin bearing leg ensures proper attachment and lap engagement
• Ideal for commercial and industrial applications
• Aluminum available on an inquiry basis
• May be used in vertical or horizontal orientation
• Class 4 impact rating
• Class A fire rating
• .032" aluminum or 26, 24 and 22 gauge steel are available
38" OVERALL
12"
1 1/2"
36" COVERAGE
ultra rib
Wind Uplift
UL90 #168
Minimum Roof Slope
1:12
Available Width
36"
Standard Lengths
6' to 40'
4 " R I B
• An industry standard — ideal for heavy industrial and lagging applications
• Available in mill finish, alclad or painted
• 8" rib available on inquiry basis
• May be used in vertical or horizontal orientation
• Available in .032", .040" and .050" aluminum in various widths
• Available in 24, 22, and 20 gauge steel in various widths
35 9/16"
32"
1"
4" RIB
Standard Available Width
32" (painted aluminum is 36"; unpainted aluminum is 44")
Standard Lengths
6' to 45'
35 9/16"
32"
1"
4" RIB
38" OVERALL
12"
1 1/2"
36" COVERAGE
ultra rib
22
E X P O S E D - F A S T E N E R P A N E L S
T E C H N I C A L D A T AV - B E A M
• Excellent strength and spanning capability
• Diaphragm capacity per ICBO Evaluation Report
• May be used in vertical or horizontal orientation
• Mitered corners are available
• Available in .032", .040" and .050" aluminum in various widths
• Available in 24, 22, and 20 gauge steel in various widths
32" COVERAGE
1 3/4"
33 7/8" OVERALL
Minimum Roof Slope
2:12
Standard Available Width
32" (painted aluminum is 32"; unpainted aluminum is 42 2/3")
Standard Lengths
6' to 45'
32" Coverage
1 3/4"
33 7/8" OVERALL
23
E X P O S E D - F A S T E N E R P A N E L S
T E C H N I C A L D A T A1 / 2 " C O R R U G A T E D
• An economical and versatile wall or roof panel
• Can be perforated for acoustical applications
• Standard 13.3% open area (1/8" diameter holes on .325" staggered centers)
• May be used in vertical or horizontal orientation
• Mitered corners are available
• Available curved
• Class 4 impact rating
• Class A fire rating
• .032", .040" and .050" aluminum are available in various widths
• 26, 24, 22, 20 and 18 gauge steel are available in various widths
OVERALL VARIES
COVERAGE VARIES
1/2"
1/2" CORRUGATED
2.667"
Minimum Roof Slope
2 1/2:12
Standard Lengths
6' to 45'
7 / 8 " C O R R U G A T E D
• Bolder look
• Great for exterior and interior uses
• Can be perforated for acoustical applications
• Standard 13.3% open area (1/8" diameter holes on .325" staggered centers)
• May be used in vertical or horizontal orientation
• Mitered corners are available
• Available curved
• .032", .040" and .050" aluminum are available in various widths
• 26, 24, 22, 20 and 18 gauge steel are available in various widths
PAINTED SIDE 7/8"
7/8" CORRUGATED
32"
2.667"
Minimum Roof Slope
2 1/2:12
Standard Lengths
6' to 45'
OVERALL VARIES
COVERAGE VARIES
1/2"
1/2" CORRUGATED
PAINTED SIDE
A. 7/8" CORRUGATEDB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"
* OPTIONAL
7/8"
7/8" CORRUGATED
32"
2.667"
25
E X P O S E D - F A S T E N E R P A N E L S
T E C H N I C A L D A T AD E E P R I B I I
• Can be used for both wall and roof applications
• May be used in vertical or horizontal orientation
• Mitered corners are available
• .032", .040" and .050" aluminum are available in various widths
• 22, 20 and 18 gauge steel are available in various widths
DEEP RIB II (ALUMINUM)
2"
40"44 1/2"
33 3/4" OVERALL
30" COVERAGE
DEEP RIB II (STEEL)
2"
ALL DIMENSIONS ARE CENTERLINE DIMENSIONS.
OVERLAP CORRUGATION
OVERLAP CORRUGATION
Minimum Roof Slope (when inverted as roof )
1:12
Available Widths
30" and 40"
Standard Lengths
6' to 45'
D E E P R I B I V
• A bold rib design, ideal for horizontal and vertical applications
• 4" deep ribs provide excellent strength and spanning capacity
• Can be used for both wall and roofs (inverted for roof)
• Excellent for applications with large spans between structural framing members
• May be used in vertical or horizontal orientation
• Mitered corners are available
• Available curved
• .032", .040" and .050" aluminum and 22, 20 and 18 gauge steel are available
12"
24" COVERAGE
25 1/4" OVERALL
4"
12"
25 1/4" OVERALL
24" COVERAGE
4"
DEEP RIB 4
Roofing
Siding
Minimum Roof Slope
1:12
Available Width
24"
Standard Lengths
6' to 45'
DEEP RIB II (ALUMINUM)
2"
3'-4"
3'-81/2"
33-7/8" OVERALL
30" COVERAGE
DEEP RIB II (STEEL)
2"
ALL DIMENSIONS ARE CENTERLINE DIMENSIONS.
OVERLAP CORRUGATION
OVERLAP CORRUGATION
12"
24" COVERAGE
25 1/4" OVERALL
4"
12"
25 1/4" OVERALL
24" COVERAGE
4"
DEEP RIB 4
Roofing
Siding
12"
24" COVERAGE
25 1/4" OVERALL
4"
12"
25 1/4" OVERALL
24" COVERAGE
4"
DEEP RIB 4
Roofing
Siding
26
E X P O S E D - F A S T E N E R P A N E L S
T E C H N I C A L D A T A
R - P A N E L
• Economic commercial and industrial wall panel
• Ideal for metal buildings, light commercial structures and modular buildings
• Material: Polyester painted GALVALUME® AZ-50 (Aluminum-Zinc Coated Steel) and Mill Finished GALVALUME® Plus AZ-55
• Full 36" net coverage based on a 41.5625" coil feed
• 1 1/4" high major ribs on 12" center with intermediate ribs for added strength and durability
• May be used in vertical or horizontal orientation
• Panels can be reverse run for wall applications offering alternate visual aesthetics
• 26 gauge steel is available
1 1/
4"
PAINTED SIDE
36"
12" 12" 12"
"R" PANEL
Minimum Roof Slope
1:12
Available Width
36"
Standard Lengths
6' to 45'
1 1/
4"
PAINTED SIDE
36"
12" 12" 12"
"R" PANEL
27
M I G H T I - R I B ®
• Excellent commercial and industrial roof, wall or fascia requiring economic covering
• Purlin bearing leg ensures proper attachment and lap engagement
• Diaphragm capacity per ICBO Evaluation Report
• UL90 rating when attached to steel purlins
• Available unpainted or finished with high-performance Enduracote® paint system in 26 gauge and PVDF in heavier gauges
• Aluminum available on an inquiry basis
• May be used in vertical or horizontal orientation
• Class 4 impact rating
• Class A fire rating
• 26 and 24 gauge available; inquire about the availability of heavier gauges
PAINTED SIDE
A. MIGHTI - RIB PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"
* OPTIONAL
36"
1 1/
4"MIGHTI - RIB PANEL
12"12"12"
Wind Uplift
UL90 #169
Factory Mutual FM Class I-90
Minimum Roof Slope
1:12
Available Width
36"
Standard Lengths
6' to 45'
PAINTED SIDE
A. MIGHTI - RIB PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"
* OPTIONAL
36"
1 1/
4"
MIGHTI - RIB PANEL
12"12"12"
E X P O S E D - F A S T E N E R P A N E L S
T E C H N I C A L D A T AU - P A N E L
• Economic commercial and industrial wall panel
• Ideal for metal buildings, light commercial structures, modular buildings and mini storage interior partition walls
• Material: Polyester painted GALVALUME® AZ-50 (Aluminum-Zinc Coated Steel) and Mill Finished GALVALUME® Plus AZ-55
• 36" coverage based on a 41.5625" coil feed
• 3/4" high major ribs at 6" centers
• May be used in vertical or horizontal orientation
• 26 gauge steel is available
PAINTED SIDE
A. "U"-PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"
* OPTIONAL
13/1
6"36"
"U" PANEL
Minimum Roof Slope
2 1/2:12
Available Width
36"
Standard Lengths
3' to 45'
P B U P A N E L
• PBU is economical commercial and industrial roof and wall panel
• Purlin bearing leg ensures proper attachment and lap engagement
• Ideal for Mini Storage partition wall panels and back side parapet wall covering
• Panel can be reverse run for wall applications offering alternate visual aesthetics
• May be used in vertical or horizontal orientation
• 26 gauge steel is available
PAINTED SIDE
A. PBU-PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"
* OPTIONAL
PBU PANEL
36"
3/4"
Wind Uplift
UL90 #39, 79
Minimum Roof Slope
2 1/2:12
Available Width
36"
Standard Lengths
3' to 45'
PAINTED SIDE
A. "U"-PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"
* OPTIONAL
13/1
6"
36"
"U" PANEL
PAINTED SIDE
A. PBU-PANELB. STITCH SCREW,#14X7/8 LAP SCREWC. SEALANT (FIELD APPLIED) *D. ATTACHMENT SCREW TO SUBSTRATE (1) INTO STEEL #12X1 SELF DRILLER (2) INTO WOOD #9X1 TYPE "A"
* OPTIONAL
PBU PANEL
36"
3/4"
28