4
F1-26 UL Listedf Simultaneous Exposure Class I, Div. 2, Class II, Div. 1 (See Page F1-22 for group designations) Class I, Div. 2; A,B,C,D Class II, Div. 1 and 2; E,F,G$ Class III._____ UL 1572, UL 844, UL 595 NEMA 4X Listings continued from preceding page Mercmaster III Enclosed and Gasketed Fixtures: High Pressure Sodium— SOW, 70W, 100W and 150W High Reactance, High Power Factor (Min. P.P. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps Type Mounting 25° ^?V Stanchion ° neHUb Lamp Watts 50 70 Hub Size (In.) 1-1/4 1-1/2 1-1/4 Catalog Numbers With With Type V Globe 8" Refractor* KPSL50125« KPSL50125J5* KPSL50150* KPSL50150J5« KPSL70125* KPSL70125J5* 100 1-1/2 1-1/4 1-1/2 KPSL70150* KPSL10125* KPSL10150* Straight Stanchion One Hub 50 70 100 150* With Globe With Refractor 1-1/4 1-1/2 1-1/4 1-1/2 1-1/4 1-1/2 1-1/4 1-1/2 KPSTL50125^ KPSTL501500 KPSTL70125* KPSTL70150* KPSTL10125* KPSTL10150* KPSTL15125* KPSTL15150* KPSL70150J5* KPSL10125J5* KPSL10150J5* With Globe With Refractor 150t 1-1/4 1-1/2 KPSL15125* KPSL15150* KPSL15125J5* KPSL15150J5* KPSTL50125J50 KPSTL50150J50 KPSTL70125J5* KPSTL70150J5* KPSTL10125J5* KPSTL10150J5* KPSTL15125J5* KPSTL15150J5* Accessory Options 0 Guards Guards are die cast cop- per-free aluminum with baked epoxy finish to match fixtures. Supplied with stainless steel mounting screws which thread into stainless steel inserts on fixture housing. To order fixture with guard, add suf- fix G to catalog number be- fore adding voltage suffix. Q Reflectors Standard dome and 30° angle polyester reflectors are shown elsewhere in this catalog section. Q Rapid Smart Starter Instantly restrikes a hot HPS lamp when power is restored after a momentary outage. Removes itself from circuit if lamp burns out or is removed from socket. Available factory- installed only. To order, add suffix -HRE to catalog number. See page F1-20. Q Quartz Emergency Light When ordered, HPS fix- tures will be supplied with a prewired special DC bay- onet base socket to accept a 150W or 250W, 120V quartz lamp (not furnished) that automatically switches on when a power outage occurs. Fixtures ordered with this quartz emergency lamp feature do NOT com- ply with requirements for classified areas and should be used only in non-clas- sifed locations. To order, add suffix -E to catalog number and specify if a re- lay switch is desired. 0 Photocell and Fuses Shown elsewhere in this catalog section. Photocell not for use in classified areas. Q Smart-Starter Has a 1-1/2-minute timer and performs as a conven- tional starter to normally start lamp. Add suffix -S to catalog number. t See table on pages F1-2F and 2G for classified area suitability of each fixture listed. « To order fixture with NEMA Type 1 refractor, change final digit 5 in Cat. No. to 1; for NEMA Type 3 refractor, change 5 to 3. « 50W fixtures have dual tap ballast for 120V and 277V only; add suffix -DT. * Add voltage suffix -MT for 120, 208, 240 or 277V; -48 for 480V. $ For 150W HPS fixtures, use S-55 lamp type only. Effective October, 1993 Copyright 1993 Printed in U.S.A. PAGE 26 Appleton • I ELECTRIC COMPANY 1701 West Wellington Avenue Chicago, Illinois 60657

F1-26 - WESCO International · F1-26 UL Listedf Simultaneous Exposure Class I, Div. 2, Class II, Div. 1 ... onet base socket to accept a 150W or 250W, 120V quartz lamp (not furnished)

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

F1-26UL ListedfSimultaneous ExposureClass I, Div. 2, Class II, Div. 1(See Page F1-22 for group designations)Class I, Div. 2; A,B,C,DClass II, Div. 1 and 2; E,F,G$Class III._____UL 1572, UL 844, UL 595NEMA 4X

Listings continued from preceding page

Mercmaster III Enclosed andGasketed Fixtures: High PressureSodium— SOW, 70W, 100W and 150WHigh Reactance, High Power Factor (Min. P.P. 90%). Heat-ResistantPrismatic Glass Globe or Closed Prismatic Glass Refractor.Mogul Base Lamps

TypeMounting

25°^?V Stanchion

°neHUb

LampWatts

50

70

HubSize(In.)

1-1/41-1 /2

1-1/4

Catalog NumbersWith With Type VGlobe 8" Refractor*

KPSL50125« KPSL50125J5*KPSL50150* KPSL50150J5«

KPSL70125* KPSL70125J5*

100

1-1 /2

1-1/41 - 1 / 2

KPSL70150*

KPSL10125*KPSL10150*

StraightStanchionOne Hub

50

70

100

150*With Globe With Refractor

1-1/41-1 /2

1-1/41-1 /2

1-1/41-1 /2

1-1/41-1 /2

KPSTL50125^KPSTL501500

KPSTL70125*KPSTL70150*

KPSTL10125*KPSTL10150*

KPSTL15125*KPSTL15150*

KPSL70150J5*

KPSL10125J5*KPSL10150J5*

With Globe With Refractor150t 1-1 /4

1 - 1 / 2KPSL15125*KPSL15150*

KPSL15125J5*KPSL15150J5*

KPSTL50125J50KPSTL50150J50

KPSTL70125J5*KPSTL70150J5*

KPSTL10125J5*KPSTL10150J5*

KPSTL15125J5*KPSTL15150J5*

Accessory Options 0 GuardsGuards are die cast cop-per-free aluminum withbaked epoxy finish to matchfixtures. Supplied withstainless steel mountingscrews which thread intostainless steel inserts onfixture housing. To orderfixture with guard, add suf-fix G to catalog number be-fore adding voltage suffix.

Q ReflectorsStandard dome and 30°angle polyester reflectorsare shown elsewhere in thiscatalog section.

Q Rapid SmartStarterInstantly restrikes a hotHPS lamp when power isrestored after a momentaryoutage. Removes itselffrom circuit if lamp burns

out or is removed fromsocket. Available factory-installed only. To order, addsuffix -HRE to catalognumber. See page F1-20.

Q Quartz EmergencyLightWhen ordered, HPS fix-tures will be supplied witha prewired special DC bay-onet base socket to accepta 150W or 250W, 120Vquartz lamp (not furnished)that automatically switcheson when a power outageoccurs. Fixtures orderedwith this quartz emergencylamp feature do NOT com-ply with requirements forclassified areas and shouldbe used only in non-clas-sifed locations. To order,add suffix -E to catalognumber and specify if a re-lay switch is desired.

0 Photocell andFusesShown elsewhere in thiscatalog section. Photocellnot for use in classifiedareas.

Q Smart-StarterHas a 1-1/2-minute timerand performs as a conven-tional starter to normallystart lamp. Add suffix -S tocatalog number.

t See table on pages F1-2F and 2G for classified area suitability of each fixture listed. « To order fixture with NEMA Type 1 refractor, changefinal digit 5 in Cat. No. to 1; for NEMA Type 3 refractor, change 5 to 3. « 50W fixtures have dual tap ballast for 120V and 277V only; addsuffix -DT. * Add voltage suffix -MT for 120, 208, 240 or 277V; -48 for 480V. $ For 150W HPS fixtures, use S-55 lamp type only.

Effective October, 1993Copyright 1993 Printed in U.S.A.

PAGE 26Appleton

• I ELECTRIC COMPANY

1701 West Wellington AvenueChicago, Illinois 60657

F1-19Mercmaster III Enclosed andGasketed HID 50-250WLighting FixturesHigh Pressure Sodium, Metal Halide and Mercury Vapor.Listed for simultaneous exposure to combustible dustsand flammable gases or vapors.

• Mounting hoods include cone-shapedpendant hood (sheds dust, helps dis-sipate fixture heat), standard pendant,ceiling and wall (tapped for 3/4" or 1"NPT), 25° angle stanchion, and straightstanchion (both tapped for 1-1/4" or1-1/2" NPT).• Cone hood fixtures for pendantmounting shed dust, dirt and combus-tible fibers. Inhibits build-up that "in-sulates" fixture and slows heat trans-fer. Also provides increased surfacearea for more effective heat dissipation.• Reflector choice includes standarddome and 30° angle types, both madeof fiberglass-reinforced white polyes-ter. Highly resistant to unusually cor-rosive applications. Reflectors arevented for cooler, dirt-free operationand maintained lumen output. Theysecure to ballast housing with stain-less steel screws threading into stain-less steel inserts.• For high corrosion resistance, fixturehousing, mounting hoods and guardsare copper-free die-cast aluminum withbaked epoxy finish, electrostaticallyapplied for uniformity. All exposedhardware is stainless steel.• Hinge has high lip for added safetyduring installation and servicing. Hingeand bolt construction assures 360°compression at all points on ballasthousing gasket for positive sealing.Swing-away design of captive bolt andnut simplifies servicing.• Body gaskets and globe gaskets arehigh-temperature silicone rubber.• Capacitors are non-PCB type, ther-mally isolated from ballast.• Mogul porcelain socket with nickel-plated contacts has 200°C weldedleads, prewired to the ballast. Assurestrouble-free operation in installationswhere high ambient temperatures areencountered.• HPS ballasts are High Power Factor(Min. P.F. 90%). SOW HPS fixtures havedual tap (120V or 277V) ballast. Allother fixtures have multi-tap ballast(120V, 208V, 240V or 277V) or 480Vballast. Ballasts are Class H insulated.• All Mercmaster III mounting hoodshave provision for easy field installa-tion of fuses in fixtures (see fuse kit

listings in this catalog section).• For electrical protection, a groundwire is provided on each Mercmasterto bond hood and ballast housing.Standard Materials• Mounting hoods, ballast bodies andguards: Die-cast copper-free alumi-num (Less than 4/10ths of 1%).• Exposed hardware is stainless steel;latch assemblies have stainless steelbolt and captive nut; reflectors andguards attach with stainless steelscrews threading into stainless steelinserts.• Reflectors: fiberglass-reinforcedwhite polyester.• Globes: heat-resistant, prismaticglass.• Refractors: heat-resistant prismaticglass.Standard Finishes• Mounting hoods, ballast bodies,guards: Epoxy powder coat finish,electrostatically applied for complete,uniform surface protection.• Reflectors: white polyester finish.Options• Fuses can be field-installed onMercmaster III fixtures. Kits includefuse block, wire connectors and screwsfor attaching to mounting hood.Fixtures with fuses do not comply withUL595 requirements for marine listing.See page F1-65 for Fuse Kits.• Rapid Smart Starter emergency op-tion, for HPS fixtures only. Restrikes ahot HPS lamp instantly when power isrestored after a momentary powerinterruption. Factory-installed on 35-150W HPS fixture. Add suffix -HRE.• "Smart-Starter" for HPS fixtures only.Incorporates a 1-1/2-minute timer andperforms as a conventional starter tonormally start lamp or to restart lampafter a momentary power interruption.Removes itself from circuit if lampburns out or is removed from socket.Eliminates starter failures caused byprolonged operation with cycling orfailing lamps and simplifies findingtheir location, reducing maintenanceand repair costs. Add suffix -S.

• Optional photocell for all fixtures ex-cept cone and ceiling mount providesautomatic "on-off" control.*• Quartz auxiliary lamps are availablefor all fixtures. Relay switch installedin fixture when specified. Add suffix•E to fixture catalog number.*Compliances*• UL Listed for Simultaneous Expo-sure, Class I Div. 2 and Class II, Div.1 and 2.• UL Standards 1572, 595 and 844.• NEMA 4X• Class I, Division 2, Groups A, B, C,and D.• Class II, Division 1 and 2, Groups E,F, G, and Class III.

* Compliance data varies for specific fixtures.Consult Appleton regarding suitability of specificfixtures for a particular application.

o Fixtures equipped with optional photocell orquartz auxiliary lamp do not comply with ULrequirements and are not suitable for use inclassified locations.

Effective August, 1994Copyright 1994 Printed in U.S.A. Appleton

• • ELECTRIC COMPANY

1701 West Wellington AvenueChicago, Illinois 60657

PAGE 19

F1-22

In compliance with the 1990 NationalElectrical Code, Mercmaster III fixturesare listed for "Simultaneous Exposure"

Technical Data:Thermal Performance ofMercmaster III FixturesTemperature Identification Numbers of Mercmaster III Fixtures forClass I, Div. 2; Class II, Div. 1 and Simultaneous Exposure toHazardous Conditions of Both Classifications.

to combinations of Class I, Div. 2 andClass II, Div. 1 hazardous conditions.The larger housing results in cooler

operation and provides an expandedrange of "T" numbers as indicated inthe following table.

"T" Numbers for Mercmaster III Fixtures

Lamp

Watts Type

50 HPS

70 HPS

100 HPS

150 HPS

100 MV

175 MV

250 MV

100 MH

175 MH

250 MH

SupplyWire °C

607575

759090

90909090

909090

75909090

9090

90

909090

9090

90

AmbientTemp.°C

405565

405565

40405565

404055

40556565

4055

40

405565

4055

40

Class I, Div. 2

GlobeT3CT3AT3A

T3BT3AT3

T3

T2DT2D

T2B

T2B

T2BT2BT2B

T2AT2A

350

T3T3T2D

T2BT2A

325

Globe &ReflectorT3BT3AT3

T3AT3AT3A

T3

T2DT2D

T2B

T2A

T2BT2BT2B

T2AT2

350

T3T3T2D

T2BT2A

325

8"RefractorT3CT3AT3A

T3CT3BT3A

T3

T3T2D

T2C

T2B

T2BT2BT2B

T2BT2A

350

T3T3T2D

T2BT2B

T2

Class II, Div. I

GroupEFGEFGEFG

EFGEFGEFG

EFEFGEFG

EFGEF

EFGEFGEFGEF

EFGEFG

EF

EFGEFG

EFGEFG

EFG

GlobeT4AT4T3C

T4T3CT3C

T3B

T3

T4T3CT3C

-

-

-

-

-

Globe &ReflectorT4T3BT3C

T3CT3CT3B

T3A

_

T3CT3B

T3A

-

-

-

-

8"RefractorT6T5T4A

T6T5T4A

T4AT4

T3C

T4AT4T3C

T3CT3C

T3A

T3CT3C

T3CT3C

T3B

Simultaneous ExposureClass 1, Div. 2/Class II, Div. 1

GlobeT3AT3T2D

T3T2DT2C

T2B

T2

T2BT2AT2A

Globe & 8*Reflector RefractorT3 T3CT3 T3AT2D T3

T3 T3AT2D T3T2C T3

T2B T2CT2B

T2B

T2A T2BT2A T2BT2 T2A

T2A- - T2A

325

T2BT2A

T2BT2A

325

"T" Numbers Represent the Maximum Lamp Temperature for Class I, Div. 2 Locations andMaximum Surface Temperature for Class II, Div. 1 Locations"T"NumberTemp.Range<°C)

T1

351-450

350

326-350

325

301-325

T2

281-300

T2A

261-280

T2B

231-260

T2C

216-230

T2D

201-215

T3

181-200

T3A

166-180

T3B

1 6 1 - 1 6 5

T3C

136-160

T4

1 2 1 - 1 3 5

T4A

101-120

T5

86-100

T6

85

Effective August, 1994Copyright 1994 Printed in U.S.A.PAGE 22 ppleton

• • ELECTBIC COMPANY

1701 West Wellington AvenueChicago, Illinois 60657

F1-40

• All fixtures designed to perform in a40° C ambient temperature. Selectedfixtures are suitable for ambient temper-atures up to 65°C.• Standard dome of 30° angle reflec-tors made of fiberglass reinforced whitepolyester. Highly resistant to corrosiveatmospheres.• Fixture housing mounting hoods andguards are die cast copper-free alumi-num with epoxy powder coat finish. Allexposed hardware is stainless steel.• A wide range of voltages available(120 to 480 volt) 60 hertz.• One-piece ballast housing for eachcomponent provides even heat dissipa-tion for cooler operation and longerballast life.• All Mercmaster mounting hoods haveprovision for easy field installation offuses in fixtures (see fuse kit listings).

Mercmaster III - 400Enclosed and Gasketed Fixtures forHazardous and Wet LocationsHigh Pressure Sodium, Metal Halide and Mercury Vapor.Listed for simultaneous exposure to combustible dusts and flammablegases or vapors.Standard Materials• Mounting hoods and ballast bodies:Die Cast aluminum (copper-free 4/10 of1% max) .• Reflectors are fiberglass-reinforcedwhite polyester.• All hardware and catch assembliesstainless steel.• Globe - heat and impact resistant in-ternally fluted glass.• Refractors - prismatic glass• Enclosed reflector: etched Alzak alu-minum with sealed, tempered heat andimpact resistant lens.• Guards: stainless steelOptions• Quartz Auxiliary comes to full bright-ness immediately and remains lit untilthe HID lamp attains 60-70% of full il-lumination. Quartz Auxiliary suppliedwith relay switch and socket to accept120V quartz double contact bayonet

base lamp (not included). (Not suitablefor hazardous locations) add suffix -E.• "Smart Starter" for HPS fixtures only.Incorporates a 1-1/2-minute timer andperforms as a conventional starter tonormally start lamp. Removes itselffrom circuit if lamp burns out or isremoved from socket. Eliminates starterfailures caused by prolonged operationwith cycling or failing lamps and sim-plifies finding their location, reducingmaintenance and repair costs. Availablefor all HPS fixtures. Add suffix -S.Compliances• UL Listed• UL 1572, UL844, UL 595• Class I, Div. 2, Groups A,B,C,D• Class II, Div. 1 and 2; Groups E,F,G• Class III• NEMA 4X• Simultaneous Exposure

Class I, Div. 2; Class II, Div. 1

Ordering Information:Order using catalog numbering guide below or select catalog number from tables on following pages.

fCATALOG NUMBERING GUIDE FOR MERCMASTER III - 400 LUMINAIRES

A

SERIES:KP - Mercmaster I

-400

L

LAMP TYPE:H - Metal HalideL - High Pressure

SodiumM - Mercury Vapor

MOUNTING:A - Pendant (rigid mounting)C - CeilingCH - Pendant Cone HoodF - Pendant (flexible mounting)ST - 90° StanchionS - 25° StanchionWB-Wall

9 10 J5

HUB SIZE:75 - 3/4" NPT1 0 - 1 " NPT

125- 1-1/4" NPTstanchion

150- 1-1/2" NPTstanchion

G MT

GUARDOPTIONS: @G - Guard

for standardglobes only

WATTAGE:25 - 250 HPS40 - 400 HPS, MH & MV

OPTICAL ASSEMBLY OJ2 - NEMA II RefractorJ5 - NEMA V RefractorR - Enclosed Reflector with

sealed lensBlank - Globe

fOPTIONS:E - Emergency

QuartzF - Fuse Kit

(specify voltage)S - Smart Starter

VOLTAGE:MT - 120/208/240/277 - 60 Hz48 - 480 - 60 HzXK - 220/240 - 50 Hz

O NO DESIGNATION is required for fixtures with standard type globe.® NO DESIGNATION is required for fixtures without guards - guards for refractors or enclosed reflector must be ordered separately, see accessories page.Refer to "Mounting Hoods and Ballast" page for available Voltage Configuration.

Effective August, 1995Copyright 1995 Printed in U.S.A.PAGE 40

1701 West Wellington AvenueChicago, Illinois 60657