1 Occupancy Sensor OCS 100C • Setup Guide The OCS 100C is a ceiling mounted occupancy sensor that incorporates ultrasonic (US) and passive infrared (PIR) into a dual technology sensor. The US sensor emits ultrasonic sound waves into an area and measures the speed of their return to detect the presence of people. Frequency changes are caused by the movement of people, which is detected by the US waves. The PIR sensor detects the presence of people based on the difference between the heat generated by moving people versus the ambient room temperature. The OCS 100C has a 24 VDC power input, ground/common connection, normally open/closed relay, photocell, and occupancy output connections. Front Panel Features Ultrasonic Sensors Green LED (status indicator) Green LED (status indicator) Retainer Ring Infrared/Photocell Lens Figure 1. OCS 100C Front Panel Features Control Blue Photocell Dial Red Infrared Sensitivity Dial Black Timer Dial Green Ultrasonic Range Dial DIP Switches (B) DIP Switches (A) al DIP A) 1 A 2 3 4 ON ON 1 B 2 3 4 1 2 3 4 1 2 3 4 Figure 2. OCS 100C Controls The settings for DIP Switches B3 (timer adjust) and B4 (sensitivity adjust) can be set to: Automatic mode — The sensors automatically adjust for changes in usage and seasons, eliminating the need for manual adjustments and improving system performance. Manual mode — The user sets the parameters of the sensors using the following dials. NOTE: The black timer dial is inactive when the B3 timer adjust DIP Switch is in Automatic mode. The red infrared sensitivity dial and green ultrasonic range dial are inactive when the B4 sensitivity adjust DIP Switch is set to Automatic mode. Ultrasonic sensors (4) — Detect movement in the room, based on ultrasonic sound waves. Green LED status indicators (2) — Flash when the ultrasonic sensors detect occupancy. Infrared/Photocell lens — Diffracts the incoming light and directs the light to the infrared/photocell sensor. The infrared/ photocell sensor, controls and DIP switches are located behind the lens. Red LED status indicator — Located behind the infrared lens, this LED flashes when the infrared sensor detects occupancy. Retainer Ring — Holds the optional IR mask in place. Remove to access all controls and DIP switches. DIP Switches A A OPERATION OFF ON 1 Not used Not used* Not used 2 Threshold Auto threshold adjustment* High sensitivity (low turn on threshold) 3 LED indicators LEDs enabled* LEDs disabled 4 Automatic adjust reset Toggle to reset (Default: OFF) *Default DIP Switches B B OPERATION OFF ON 1 Strong airflow compensator Disabled* Enabled 2 Over doorway mount Disabled* Enabled 3 Timer adjust Automatic Manual* 4 Sensitivity adjust Automatic Manual* *Default

Extron OCS 100C Setup Guide · 2 Occupancy Sensor OCS 100C • Setup Guide (Continued) • Black Timer Dial (see figure 2 on the previous page) — The occupancy sensor has a built

Embed Size (px)

Citation preview

Page 1: Extron OCS 100C Setup Guide · 2 Occupancy Sensor OCS 100C • Setup Guide (Continued) • Black Timer Dial (see figure 2 on the previous page) — The occupancy sensor has a built

1

IMPORTANT:

Go to www.extron.com for the

complete user guide, installation

instructions, and specifications.

Occupancy Sensor OCS 100C • Setup Guide

The OCS 100C is a ceiling mounted occupancy sensor that incorporates ultrasonic (US) and passive infrared (PIR) into a dual technology sensor. The US sensor emits ultrasonic sound waves into an area and measures the speed of their return to detect the presence of people. Frequency changes are caused by the movement of people, which is detected by the US waves. The PIR sensor detects the presence of people based on the difference between the heat generated by moving people versus the ambient room temperature.

The OCS 100C has a 24 VDC power input, ground/common connection, normally open/closed relay, photocell, and occupancy output connections.

Front Panel Features

Blue Photocell Dial

Red InfraredSensitivity Dial

Black Timer Dial

Green UltrasonicRange Dial

DIP Switches (B)DIP Switches (A)

UltrasonicSensors

Green LED(status indicator)

Green LED(status indicator)

Retainer Ring

al

DIPA)

1A

234

ON ON

1B

234

12

34

12

34

Infrared/Photocell Lens

Figure 1. OCS 100C Front Panel Features

Control

Blue Photocell Dial

Red InfraredSensitivity Dial

Black Timer Dial

Green UltrasonicRange Dial

DIP Switches (B)DIP Switches (A)

UltrasonicSensors

Green LED(status indicator)

Green LED(status indicator)

Retainer Ring

al

DIPA)

1A

234

ON ON

1B

234

12

34

12

34

Infrared/Photocell Lens

Figure 2. OCS 100C Controls

The settings for DIP Switches B3 (timer adjust) and B4 (sensitivity adjust) can be set to:

• Automatic mode — The sensors automatically adjust for changes in usage and seasons, eliminating the need for manual adjustments and improving system performance.

• Manual mode — The user sets the parameters of the sensors using the following dials.

NOTE:• The black timer dial is inactive when the B3 timer adjust DIP Switch is in Automatic mode.

• The red infrared sensitivity dial and green ultrasonic range dial are inactive when the B4 sensitivity adjust DIP Switch is set to Automatic mode.

• Ultrasonic sensors (4) — Detect movement in the room, based on ultrasonic sound waves.

• Green LED status indicators (2) — Flash when the ultrasonic sensors detect occupancy.

• Infrared/Photocell lens — Diffracts the incoming light and directs the light to the infrared/photocell sensor. The infrared/photocell sensor, controls and DIP switches are located behind the lens.

• Red LED status indicator — Located behind the infrared lens, this LED flashes when the infrared sensor detects occupancy.

• Retainer Ring — Holds the optional IR mask in place. Remove to access all controls and DIP switches.

1

2 • DIP Switches A —

A OPERATION OFF ON

1 Not used Not used* Not used

2 Threshold Auto threshold adjustment*

High sensitivity (low turn on threshold)

3 LED indicators LEDs enabled* LEDs disabled

4 Automatic adjust reset Toggle to reset (Default: OFF)

*Default

• DIP Switches B —

B OPERATION OFF ON

1 Strong airflow compensator

Disabled* Enabled

2 Over doorway mount Disabled* Enabled

3 Timer adjust Automatic Manual*

4 Sensitivity adjust Automatic Manual*

*Default

Page 2: Extron OCS 100C Setup Guide · 2 Occupancy Sensor OCS 100C • Setup Guide (Continued) • Black Timer Dial (see figure 2 on the previous page) — The occupancy sensor has a built

2

Occupancy Sensor OCS 100C • Setup Guide (Continued)

• Black Timer Dial (see figure 2 on the previous page) — The occupancy sensor has a built in timer feature. When the sensor detects motion, it instantly triggers ON (high).

Once occupancy is no longer detected, the timer begins. If no motion is detected and the timer expires, then the sensor triggers OFF (low).

Use the black timer dial to set the amount of time before the sensor triggers OFF.

NOTE: B3 DIP Switch must be set to ON for Manual mode, in order to adjust the timer manually.

• Ranges from 8 minutes to 42 minutes.

• Full counter clock wise (CCW) = 8 minutes

• Full clock wise (CW) = 42 minutes

• To enter the test mode (8 second timer) follow the steps below:

1. Open the retainer ring.

2. Rotate the black timer dial to about midway (12 o’clock).

3. Return to minimum setting (full CCW).

4. The timer will remain in the 8 second test mode for 1 hour, then automatically reset to 8 minutes.

5. To manually force the timer out of the 8 second test mode, turn the timer adjustment approximately 1/16 inch clockwise. The setting is slightly above minimum (just above the 8 minute setting.

• Red Infrared Sensitivity Dial — Adjust this dial to increase or decrease infrared sensitivity.

• Turn clockwise (CW) to increase sensitivity.

• Turn counter clockwise (CCW) to decrease sensitivity.

• The factory default setting is at 75%.

• Green Ultrasonic Range Dial — Adjust this dial to increase or decrease ultrasonic sensitivity.

• Turn clockwise (CW) to increase sensitivity.

• Turn counter clockwise (CCW) to decrease sensitivity.

• The factory default setting is at 50%.

NOTE: B4 DIP Switch must be set to ON for Manual mode, in order to adjust the Red Infrared Sensitivity Dial or the Green Ultrasonic Range Dial manually.

• Blue Photocell Dial — The photocell prevents the sensor from turning on when the area is adequately lit with natural light and motion is detected. The sensor must be mounted directly over an area that is representative of the average, natural room lighting. Before setting the photocell control, wait until the natural light is brightest (optional). Adjust this dial to increase or decrease photocell sensitivity.• Turn counter clockwise to decrease photocell sensitivity, causing it to activate with less light.• Turn clockwise to increase photocell sensitivity, requiring brighter light to activate the sensor.• Factory default is 100% (full clockwise).• Full clockwise — Photocell sensor is disabled.• Range — 10 to 1000 LUX

Page 3: Extron OCS 100C Setup Guide · 2 Occupancy Sensor OCS 100C • Setup Guide (Continued) • Black Timer Dial (see figure 2 on the previous page) — The occupancy sensor has a built

3

Mask Patterns and Sensor CoverageAn infrared mask may be needed to achieve the desired sensory coverage. Any area masked will block the PIR sensor from detecting motion in that area.

Center Ceiling Mount(mask blocks sensor seeingout doorway into hallway)

Corner Ceiling Mount(no mask needed)

Typical Mask Patterns

Using the Infrared Mask

ConferenceRoom Mask

RectangularAreas

Over the Door Specific Areas to Mask

180º Mask Full Mask

32'(10 m)

23'(7 m)

64'(20 m)

45'(14 m)

12'(4 m)

22'(7 m)

Sensory CoverageUS Minor Motion

US Major Motion

IR Minor Motion

IR Major Motion

Hal

lway

Hal

lway

Specific AreaMasked

No Mask Needed

U.S. Patents: 6151529, 5946209, 5699243, 5640143, 6415205,

6078253, D404326, 6222191, 5986357, 6759954

67E4

Appliance C

ontrol

3(m

ax Disabled)

ThresholdN

ot Used

OCS 100C

68-3155-52 Rev. A

Extro

n Head

quarters

+1.800.633.9876 (Insid

e US

A/C

anada O

nly)E

xtron U

SA

- West

+1.714.491.1500

+1.714.491.1517 FA

X

ww

w.extro

n.com

Center ofSensor Coverage

Figure 3. Mask Patterns and Sensor Coverage Diagrams

3

NOTE: These coverage dimensions are achieved when the OCS 100C is installed 10 feet (3 m) above the coverage area.

Page 4: Extron OCS 100C Setup Guide · 2 Occupancy Sensor OCS 100C • Setup Guide (Continued) • Black Timer Dial (see figure 2 on the previous page) — The occupancy sensor has a built

4

Occupancy Sensor OCS 100C • Setup Guide (Continued)

Installation

Insert wiring throughcover plate.

Insert wiring throughmounting post.

Ceiling

Ceiling

Ceiling

Cutting End

MountingPost

ThreadedMounting Post

Nut

Washer

Cover Plate

Cover Plate

Cover Plate

Sensor Body

Sensor Body

Conference RoomMask

*

*

*

Full Mask

180º Mask

Infrared Lens w/Retainer Ring

Sensor Body

Mounting Bolts (2)

Nut and Washer (2 ea)

Ceiling

Body

Screw and mount thetwist-lock cover plate.

Secure coverplate to the ceiling.

1Twist and lock threadedmounting post into thecover plate. Drill intoceiling tile.

2

4

Secure mountingpost to the ceiling tile withnut and washer.

Connect building wiring towiring harness with wire nuts.

2

4

3

Attach sensor body to cover plateby aligning arrows and twist lockinto place.

5

Connect building wiring towiring harness with wire nuts.

3

Installation Method 1

Installation Method 2

OCS 100C Parts

S

C

30˚ Adjustment

1

U.S. Patents: 6151529, 5946209, 5699243, 5640143, 6415205,

6078253, D404326, 6222191, 5986357, 6759954

67E4

Appliance Control

OCS 100C

68-3155-52 Rev. A

Extron Headquarters

+1.800.633.9876 (Inside USA/Canada Only)

Extron USA - West

Made in China

+1.714.491.1500+1.714.491.1517 FAX

www.extron.com

Center of

Sensor Coverage

A1 Not Used

A2 Threshold: OFF = low sensitivity, ON = high sensitivity

A3 LED Control: OFF = LEDs active, ON = LEDs disabled

A4 Automatic Adjust Reset: Toggle to reset

B1 Strong Air�ow Compensator: OFF = disable, ON = enable

B2 Over Doorway Mounting: OFF = disable, ON = enable

B3 Timer Adjust: OFF = automatic, ON = manual

B4 Sensitivity Adjust: OFF = automatic, ON = manual

Switch Settings: All switches OFF for full automatice operation

Relay Contacts:

Blue/White = common

Black/White = N.C.

Yellow/White = N.O.

Black : Ground

Red: +24VDC

Blue: Occupancy control output

Grey: Occupancy &

Photocell controloutput

Connections

Red: Infrared Range - 75% Default

Black: Timer - 8 min to 42 max - min Default

Green: Ultrasonic Range -50% Default

Blue: Photocell - max Default

Adjustment Knobs

Match either arrow shown here

with the arrow on the twist-lock cover

plate. Then inserts the tabs into

the slots. Twist until

ratchet action indicates

engagement.

Range of adjustment (click turn)

Figure 4. Installation Diagram

4

NOTE: *Only use a mask if the PIR sensor needs to be blocked. Only one mask should be installed at any given time.

ATTENTION:• All structural steps and electrical installation must be

performed by qualified personnel in accordance with local and national building codes and electrical codes.

• Toute étape structurelle et installation électrique, doit être effectuée par un personnel qualifié, conformément aux codes du bâtiment, aux codes incendie et sécurité, et aux codes électriques, locaux et nationaux.

Page 5: Extron OCS 100C Setup Guide · 2 Occupancy Sensor OCS 100C • Setup Guide (Continued) • Black Timer Dial (see figure 2 on the previous page) — The occupancy sensor has a built

5

Connections

Black Ground

Red +24 VDC

Blue Occupancy control output

Gray Occupancy and photocell control output

NOTE:• The gray wire is used when

the control system needs to know when the area is adequately lit with natural light and when motion is detected (for example, automatic lighting control through an Extron control system).

• When wiring the blue or gray wires of the OCS to Extron products with Digital or FLEX Input ports, configure the ports as Input without pull up. The sensor provides approximately 21 VDC in the ON (High) state and 0 VDC in the OFF (Low) state.

NOTE: Relay contacts could be used to trigger third party devices, such as HVAC, based on occupancy.

OCS 100C Wiring Diagram

ExtronIPCP PRO 550Control Processor

Dual Zone

Single Zone

RO 550

LAN

IPCP PRO 550

MAC: 00-05-A6-XX-XX-XX

S/N: ####### E######

00-05-A6-XX-XX-XX

5A MAX

100-240V ~ 50-60Hz1 1 2 3 72 1 2 3 4 1 2 3 4 PWR OUT = 9W

eBUS+V +S -S GTx Rx G Tx Rx G Tx Rx G Tx Rx G S G S G S G S GRTSCTS

SWITCHED 12 VDC40W MAX TOTAL

3 4 84 5 6 5 6 7 8 5 6 7 8 321 4 G

FLEX I/ORELAYSIR/SERIALCOM12 VDCS G S G S G S GTx Rx G Tx Rx G Tx Rx G Tx Rx G RTSCTS

ECM DIO8

BUS ID

eBU

S+

V O

UT

24G

G-S

+S

+V

DIG

ITA

L I/

O1

23

4G

G6

57

8

LSB

MSB

ExtronECM DIO8eBUS Control Module

ExtronPC 1224Power Module Extron

OCS 100COccupancySensor 2

Extron

ExtronOCS 100COccupancySensor

Extron

ExtronOCS 100COccupancySensor 1

Extron

Control Signal #2 (Blue)

Control Signal #1 (Blue)

Sensor with 12 VDCPower Supply

Sensor with 24 VDCPower Supply

Control Signal #1 (Blue)

Ground(Black)

Ground(Black)

Ground (Black)

Ground (Black)

+24 V (Red)

+24 V (Red)

+12 V (Red) E t1.

25 A

MAX

75 m

A M

AX

1.5 A MAX

PC 1224

33-2665-01 Bwww.extron.com

24V

O

UT

12V

O

UT12V

IN

Figure 5. OCS 100C Wiring Diagram

Relay Contacts

Blue/White Common

Black/White Normally closed when unoccupied

Yellow/White Normally open when unoccupied

PC 1224 Wiring

ATTENTION:• Do not connect power until you have read the ATTENTIONS: notices on the next page.

• Ne branchez pas l’alimentation avant d’avoir lu les mises en garde «ATTENTIONS » de la page suivante.

• Remove power from the system before making any connections.

• Mettez le système hors tension avant d’effectuer tout raccordement.

The OCS 100C requires 24 VDC. If the sensors are connected to a device that does not provide 24 VDC, use the included PC 1224 power module:

1. Connect a 12 VDC power source to the 12 VDC input on the supplied PC 1224 power converter, using a 2-pole captive screw connector.

2. Wire the PC 1224 24 VDC 2-pole captive screw connector to the black and red wires on the OCS 100C.

A 12 VDC pass-through is available to power additional 12 VDC devices.

5

ExtronPC 1224Power Module

12 V PowerSource

AdditionalDevices

OccupancySensor

1.25

A M

AX75

mA

MAX

1.5 A MAX

PC 1224

33-2665-01 Bwww.extron.com

24V

O

UT

12V

O

UT12V

IN

Page 6: Extron OCS 100C Setup Guide · 2 Occupancy Sensor OCS 100C • Setup Guide (Continued) • Black Timer Dial (see figure 2 on the previous page) — The occupancy sensor has a built

68-3155-51 Rev. E 02 18

© 2017-2018 Extron Electronics — All rights reserved. www.extron.com All trademarks mentioned are the property of their respective owners.

Troubleshooting

Problem Possible Cause Test Solution

Sensor remains on. Constant noise. Reduce both green and red knobs by 1/4 turn and remove noise source.

Move sensor to a less noisy area within the room.

Sensor remains on too long. Timer setting is too high. Check DIP switch settings. Reduce timer setting.

Hallway traffic turns sensor on.

Infrared sensor can see into the hallway.

Put sensor in timer test mode and walk the hallway.

Move sensor, so it cannot see into the hallway.

Safety Instructions

For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron Safety and Regulatory Compliance Guide on the Extron website.

FCC Class A Notice

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference. This interference must be corrected at the expense of the user.

NOTE: For more information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron Safety and Regulatory Compliance Guide on the Extron website.

Power Attentions

ATTENTIONS:• These products are intended for use with a UL Listed LPS type power source.

• Ces produits doivent être utilisés avec une source d’alimentation de type LPS certifiée UL.

• Use of a non-LPS or unlisted power supply will void all regulatory compliance certification.

• L’utilisation d’une source d’alimentation non-listée ou non-listée LPS annulera toute certification de conformité réglementaire.

• Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location, Pollution Degree 2, secured to the equipment rack within the dedicated closet, podium, or desk.

• Sauf mention contraire, les adaptateurs CA/CC ne conviennent pas à une utilisation dans les espaces d’aération ou dans les cavités murales. La source d’alimentation doit être placée à proximité de l’équipement Extron dans un emplacement ordinaire soumis à un degré de pollution de catégorie II, solidement fixé au rack d’équipement d’une baie technique, d’un pupitre, ou d’un bureau.

• The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical Code part 1, section 16.

• Cette installation doit toujours être conforme aux dispositions applicables du Code américain de l’électricité (National Electrical Code) ANSI/NFPA 70, article 725, et du Code canadien de l’électricité, partie 1, section 16.

• The power supply shall not be permanently fixed to building structure or similar structure.

• La source d’alimentation ne devra pas être fixée de façon permanente à la structure de bâtiment ou à d’autres structures similaires.