Extinguisher 111

Embed Size (px)

Citation preview

  • 8/6/2019 Extinguisher 111

    1/2

    DEAD EASY.No wiring.

    No piping.

    No connections.

    No-brainer...

    Automatic fire protectionfor everyday applications...

    Where fast burning, high heat-producing

    materials are stored or used;

    Where electricity is inaccessible or unreliable;

    Where other systems would be too costly;

    Where a first line of defence is needed to

    prevent damage from a sprinkler system.

    inControl Brand Automatic Clean Agent Extinguishers

    24/7 unattended fire protection

    ULC listed

    Accepted by the Canadian Coast Guard

    Approved for use in occupied areas

    Suitable for Class A, B, & C hazards

    Simple installation and maintenance

    No residue safe for sensitive equipment

    Self-contained no external power necessary

    Optional manual operation

    Mobile Spaces...CommercialBoats

    Pleasure BoatsRecreational

    Vehicles

    Locomotives

    Tractor Trailers

    Mobile Equipment

    Physical Plant...Diesel GeneratorEnclosures

    Furnace Rooms

    Pump Stations

    Janitor Closets

    Difficult-to-Service Areas...

    TemporaryBuildings

    Isolated Facilities

    MoveableEnclosures

    Storage Areas...Chemicals

    Paints

    FlammableLiquids

    Fuel

    Paper Files

    Electronic Data

    SpecialApplications...

    Computer Room

    Dry CleaningPlants

    Spray Booths

    TransformerVaults

    24/7unattendedfireprotection!

    Contact your inControl Authorized Dealer for product specifications, installation details and application information.

  • 8/6/2019 Extinguisher 111

    2/2

    4" (102 mm) minimum distance12" (305 mm) maximum distance

    Vertical Mountingon Wall

    CylinderStraps

    Horizontal Mounting on Ceiling

    Sprinkler at left hand endPressure guage facing floor

    Corner Mountingon Wall

    Easy installation...

    Maximum Volume Protected at 70 F (21 C)

    ModelClass A Hazards Class B Hazards

    ft m ft m

    NAE-1 119.0 3.37 78.7 2.23

    NAE-2 195.0 5.50 128.2 3.63

    NAE-4 390.0 11.00 256.4 7.26

    NAE-9 878.0 24.85 578.0 16.37

    NAE-12 1,170.0 33.00 771.0 21.83

    NAE-16 1,560.0 44.00 1,027.6 29.10

    For illustrative purposes only. Consult the product literature for detailed ap-

    plication information.

    Not to be used for installation purposes. Consult the instruction manual for details

    concerning specific hazards and conditions.

    14"(356 mm)

    4"(108 mm)

    NAE-1

    NAE-2

    19"(483 mm)

    5 "(130 mm)

    18/

    NAE-4

    7 /1

    8 "(181 mm)

    21"(546 mm)

    NAE-9

    175 8/ "(448 mm)

    123 8/ "(314 mm)

    NAE-12

    NAE-16

    Simple selection...

    Use only one cylinder assembly for a single protected area. For large spaces, enquireabout an engineered system.

    Ensure the discharge nozzle rating is suitable for the space being protected. (The highesttemperature expected in the space plus approximately 50 F (28 C).

    Locate the unit high on a wall, with the discharge nozzle 4 to 12 inches (102 to 305 mm) fromthe ceiling. Installation in the corner of the room keeps the extinguisher out of the way.

    Install the extinguisher so that the pressure gauge is easily seen for maintenance.

    Do not install cylinder close to any high-heat source such as space heaters.

    Ensure there is nothing in front of the discharge nozzle that would interfere with agentdischarge and disbursement.

    For small units. An arrow on the cylinder indicates possible vertical and horizontal ori-entations. Loosely mount cylinder mounting straps onto a solid structural member, slidecylinder in between the straps, then tighten the mounting bolts.

    Large units must be mount-ed vertically. Bolt the bracketonto a solid structural mem-

    ber, then install cylinder tothe bracket.

    The nozzle must dischargehorizontally, and preferablytowards the main hazardin the space or towards thecentre of the space beingprotected.

    Never install an extinguisherupside down.

    On-boardpressure gaugefor addedconfidence.

    Integrated heat detectorreacts instantly to fireconditions.

    Accessory connectionsfor pressure switch,discharge indicator, ormanual operation.

    NAF-SIII clean agentprovides powerful,effective fireprotection.

    Worry-free

    maintenance...

    GO FIGURE.