2
External Swivel Used for Step Degree Angles a) Adjust external swivel to desired angle and install set screw. b) Cut ADA tube with aluminum to desired length. c) Insert external swivel bracket into the ADA tube. d) Pre drill aluminum reinforced ADA tube and bracket with drill bit and install self tapping screw provided. P-Loop Return is Used at the Bottom of Steps or Handicap Ramps a) Attach top bracket at desired location using appropriate connectors. b) Cut P-Loop to desired length. c) Connect P-Loop to ADA tube using the appropriate joiners (Straight, Adjustable joiners or External swivel). d) Set P-Loop on top of bracket and pre drill with drill bit and install self tapping screw provided. e) Install desired lower bracket. External Swivel - 0 to 60° P-Loop Return Typical ADA Railing Installation Components: ADA Handrail w/Aluminum Insert 6” Straight Joiner 4” Inside/Outside Corner Straight End Wall Bracket Inside Corner Bracket End Cap P-Loop Return 6” Adjustable Joiner 90° Quick Return Bracket External Swivel Stand Off Bracket 5°, 32°, or 38° Radius Bend 1 1 1 1 2 3 3 3 4 4 5 5 6 7 7 8 8 9 9 10 10 11 12 11 11 or 12 or 8 10 or 12 or Optional Beauty Ring Joint Cover (Use As Necessary) ADAinstall314_ADA 4/23/14 2:39 PM Page 1

External Swivel - 0 to 60° Typical ADA Railing Installation...ADAinall314_ADA 4/23/14 2:39 PM Page 1 90 Degree Quick Return Bracket Used for Both Post and Wall Returns a) Cut ADA

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: External Swivel - 0 to 60° Typical ADA Railing Installation...ADAinall314_ADA 4/23/14 2:39 PM Page 1 90 Degree Quick Return Bracket Used for Both Post and Wall Returns a) Cut ADA

External Swivel Used for Step Degree Angles

a) Adjust external swivel to desired angle and install set screw.b) Cut ADA tube with aluminum to desired length.c) Insert external swivel bracket into the ADA tube.d) Pre drill aluminum reinforced ADA tube and bracket with drill bit

and install self tapping screw provided.

P-Loop Return is Used at the Bottom of Steps or Handicap Ramps

a) Attach top bracket at desired location using appropriate connectors.

b) Cut P-Loop to desired length.c) Connect P-Loop to ADA tube using the appropriate joiners

(Straight, Adjustable joiners or External swivel).d) Set P-Loop on top of bracket and pre drill with drill bit

and install self tapping screw provided.e) Install desired lower bracket.

External Swivel - 0 to 60°

P-Loop Return

Typical ADA Railing InstallationComponents:

ADA Handrail w/Aluminum Insert

6” Straight Joiner

4” Inside/Outside Corner

Straight End WallBracket

Inside Corner Bracket

End Cap

P-Loop Return

6” Adjustable Joiner

90° Quick ReturnBracket

External Swivel

Stand Off Bracket

5°, 32°, or 38°Radius Bend

1

1

1

1

2

33

3

4

4

5

5

6

7

7

8

8

9 9

10

10

11

12

11

11

or 12or

8 10or 12or

Optional Beauty RingJoint Cover(Use As Necessary)

ADAinstall314_ADA 4/23/14 2:39 PM Page 1

Page 2: External Swivel - 0 to 60° Typical ADA Railing Installation...ADAinall314_ADA 4/23/14 2:39 PM Page 1 90 Degree Quick Return Bracket Used for Both Post and Wall Returns a) Cut ADA

90 Degree Quick Return Bracket Used for Both Post and Wall Returns

a) Cut ADA tube with aluminum to desired length.b) Insert 90 degree quick return bracket into the

ADA tube.c) Install counter sunk screws provided through

the bracket.d) Pre-drill aluminum reinforced tube and bracket

with drill bit and install self tapping screw provided.

Straight End Wall Bracket Used for Straight Wall Connections

a) Cut ADA tube with aluminum to desired length.b) Insert straight end bracket into the ADA tube.c) Install counter sunk screws provided through

the bracket.d) Pre-drill aluminum reinforced tube and bracket

with drill bit and install self tapping screw provided.

Internal 6” Adjustable Joiner Used for Degree Angles

a) Miter cut ADA tube with aluminum to desired length.b) Install adjustable joiner inside both ends of the tube.b) Pre drill ADA tube and adjustable joiner with drill

bit and install self tapping screw provided.

4” Corner Can Be Used for Both Inside and Outside Corners

a) Install 2 straight joiners into the 4" inside/outside corner.b) Pre drill 4" inside/outside corner and straight joiner with drill bit

and install self tapping screw provided.c) Cut ADA tube with aluminum to desired length.d) Pre drill aluminum reinforced ADA tube and joiner with drill bit

and install self tapping screw provided.

4” Inside/Outside CornerBracket

a) Install counter sunk screws provided through the bracket intothe mounting surface (corner of post).

b) Place 4" inside/outside corner at appropriate location on thebracket.

c) Pre drill 4" inside/outside corner with drill bit and install self tapping screw provided.

Internal 6” Straight Joiner Used to Connect 2 ADA Tubes or 4” Inside/Outside Corner

a) Cut ADA tube with aluminum to desired length.b) Pre drill aluminum reinforced ADA tube and

joiner with drill bit and install self tapping screw provided.

90° Quick Return Bracket Straight End Wall Bracket

Stand Off Bracket 6” Straight Joiner

6” Adjustable Joiner - 0 to 90°

4” Inside/Outside Corner with Inside Corner Bracket

Stand Off Bracket Used for RailApplications on Walls or Posts

a) Install counter sunk screws providedthrough the bracket into the mount-ing surface.

b) Place rail at appropriate location onthe bracket.

c) Pre-drill aluminum reinforced ADAtube with drill bit and install selftapping screw provided.

d) Place end cap on rail.

ADAinstall314_ADA 4/23/14 2:39 PM Page 3