15
Architectural Products Exterior Expansion Joint Systems

Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

Architectural Products

Exterior Expansion Joint Systems

Page 2: Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

Why Inpro®04 Why Inpro®

Exterior Systems06 Model Number Guide08 Selection Guide12 600 Series20 Transitions

Recent Projects 26 Recent Projects26

0604

They're not just Expansion Joint Systems.

They’re masters of movement.

JOINTMASTER® Expansion Joint Systems

Acoustic authorities. Waterproofing warriors. Forbidders of Fire. Air and moisture mercenaries. They’re on a mission to maintain the integrity of buildings in the face of earthquakes, hurricanes, fires and just plain everyday forces. Often the unsung heroes of building protection, they’re built to do what they do every day because that’s what it takes to keep people safe.

inpro.com | 800.222.5556obsessed with protecting buildings™ 32

Page 3: Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

whyOur Expansion Joint + Fire Barrier Systems are engineered to handle the unique conditions of your building.

engineeredobsessively

We constantly test and review our systems for continuous innovation to provide you with the best solutions. Yeah we're obsessed, but in a good way.

protectedby design

From ensuring smooth transitions for rolling equipment carts, gurneys and wheelchairs, to preventing the spread of smoke and fire, we integrate building protection right into the product's design.

manufacturedwith care

As the manufacturer, we verify that only the best products are shipped out to your project.

ChristChurch, Justice + Emergency Services Precinct | Christchurch, New Zealand 353 Wall + Ceiling System

inpro.com | 800.222.5556obsessed with protecting buildings™ 54

Page 4: Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

Series/ModelNumber

Condition JointWidth

JOINTWIDTH

CONDITION

FRAMEHEIGHT

SEAL COLOR

101 - A01 - 025

Loading DefinitionsStandard/Moderate/Heavy Duty are designations as they relate to load ratings. These are provided as a guideline to assist in making a preliminary product selection for a given application.

• “Standard” suggests use in common applications such as typical office settings or other spaces where pedestrian traffic or occasional rubber-wheeled traffic like mail carts and light-weight cleaning equipment, luggage, etc. is the norm.

• “Moderate” suggests applications where occasional heavier maintenance equipment with soft rubber tires (such as gurneys, light duty scissor lifts, motorized cleaning equipment, etc.) would be added to the standard traffic. The systems in this category are comprised of heavier aluminum extrusions, with thicker walled extruded rubber inserts.

• “Heavy Duty” is for applications where truly heavy loads (such as vehicles) or high-point loads (such as mobile medical equipment, coin carts, materials handling equipment, etc.) are the norm. They are capable of multi-directional movements and are also available in surface or blockout mounted variations.

Forest Park Middle School | Franklin, WI114 ceiling system, 432 floor system, 300 wall system

JOINT WIDTH

Model Number GuideUnderstanding product numbersWe’ve made it even easier for you to place the right system configuration in your next project. Just visit inpro.com to download our industry leading specifications which are adaptable and easy to work with...just like us!

Series | Model 100 Elastomeric Seal Systems for Floors/Walls/Ceilings 200 Dual Elastomeric Seal Systems for Floors/Walls/Ceilings 300 Glide Plate Seismic Systems for Floors/Walls/Ceilings 400 Center Bar Seismic Systems for Floors/Walls/Ceilings 500 Seismic Systems for Floors 600 Exterior Seismic Systems for Walls and Roofs 700 Heavy Duty Seismic Systems for Floors 800 Cover Plate Systems for Floors / Walls / Ceilings 900 Fire Barrier Systems 1000 Exterior Compression Seals 1100 Foam Seals 1200 Silicone Foam Seals

Condition A01 Floor to Floor/Roof to Roof A02 Floor to Wall/Roof to Wall A07 Wall to Wall or Ceiling to Ceiling A09 Wall to Corner or Ceiling to Wall V18 Ceiling to Wall for Acoustical Ceiling Systems V24 Ceiling to Ceiling for Acoustical Ceiling Systems

Joint Width 025 1" (25mm) 038 1½" (38mm) 050 2" (51mm) 075 3" (76mm) 100 4" (102mm) 125 5" (125mm) 150 6" (152mm) 200 8" (203mm) 300 12" (305mm) 350 14" (356mm) 400 16" (406mm) 450 18" (457mm) 500 20" (508mm) 600 24" (600mm)

inpro.com | 800.222.5556obsessed with protecting buildings™ 76

Page 5: Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

Exterior Systems

Page Number 12 16 17 22

Series 600 300E, 600 600 600

Models 615, 616 300E, 601, 651 651, 661, 691 672, 674

Joint Opening 2"-36" (50mm – 900mm) 1"-24" (25mm – 600mm) 1"-36" (25mm – 900mm) 2"-36" (50mm – 900mm)

Movement +/- 50% of Joint Width 50% of Joint Width 50% of Joint Width 50% of Joint Width

Pleated Seal System Metal Roof SystemMetal Wall System Bellows Roof System

Oregon Health And Science University, Portland, OregonFloor Systems, Interior + Exterior Wall Systems, Roof Systems, Insulated Vapor Barrier

inpro.com | 800.222.5556obsessed with protecting buildings™ 98

Page 6: Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

Austin Bergstrom International Airport | Austin, TX1200 Foam, 615 Exterior Wall System, 620 Exterior Wall System, 114 Wall + Ceiling System,

115 Wall + Ceiling System, 432 Floor System, 806 Floor System, 925 Fire Barrier

Page 7: Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

H1

WS

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to Wall

616-A07-200 8" 200 3" 75 * * 8" 200 * * 4" 102 4" 102616-A07-250 10" 250 3" 75 * * 10" 250 * * 5" 127 5" 127616-A07-300 12" 300 3" 75 * * 12" 300 * * 6" 152 6" 152616-A07-450 18" 450 3" 75 * * 18" 450 * * 9" 229 9" 229616-A07-600 24" 600 3" 75 * * 24" 600 * * 12" 305 12" 305

Wall to Corner

616-A09-200 8" 200 3" 75 * * 8" 200 * * 4" 102 4" 102616-A09-250 10" 250 3" 75 * * 10" 250 * * 5" 127 5" 127616-A09-300 12" 300 3" 75 * * 12" 300 * * 6" 152 6" 152616-A09-450 18" 450 3" 75 * * 18" 450 * * 9" 229 9" 229616-A09-600 24" 600 3" 75 * * 24" 600 * * 12" 305 12" 305

Larger sizes available.

Throat-mount brackets reduce sightline to width of seal only.Insulated Vapor Barrier option available.Pleated Santoprene™ Seal design allows for fluid seismic movement.

A

C

B

A

C

B

Pleated Seal Systems% of Movement ± 50% | Joint Width 2" (50mm) – 24" (600mm)

Protection that seamlessly integrates into any building facade using our Santoprene™ Seals.

• Industry unique seal maintains tight, linear profile.• Linear Santoprene™ Seal design allows for fluid seismic movement during joint expansion and contraction.• Field heat-weldable Santoprene™ Seals for weather tight seams and crisp transitions.• Seal walls are among the thickest in the industry to allow for installation in soffits and corridor ceilings with no sagging.

615 Series - Flush Mount

616 Series - Flush Mount

A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown)

A07 Wall/Wall, Ceiling/Ceiling (12" (300 mm) system shown)

A09 Wall/Corner Wall/Ceiling (3" (75mm) system shown)

H1

H1

H1W

W

W

S

S

S

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall/WallCeiling/Ceiling

615-A07-050 2" 51 2 3/8" 60 * * 2" 51 * * 1" 25 1" 25615-A07-075 3" 76 2 3/8" 60 * * 3" 76 * * 1 1/2" 38 1 1/2" 38615-A07-100 4" 102 2 3/8" 60 * * 4" 102 * * 2" 51 2" 51615-A07-125 5” 127 2 3/8” 60 * * 5” 127 * * 2 1/2” 63 2 1/2” 63615-A07-150 6" 152 2 3/8" 60 * * 6" 152 * * 3" 76 3" 76

Wall/CornerWall/Ceiling

615-A09-050 2" 51 2 3/8" 60 * * 2" 51 * * 1" 25 1" 25615-A09-075 3" 76 2 3/8" 60 * * 3" 76 * * 1 1/2" 38 1 1/2" 38615-A09-100 4" 102 2 3/8" 60 * * 4" 102 * * 2" 51 2" 51615-A09-125 5” 127 2 3/8” 60 * * 5” 127 * * 2 1/2” 63 2 1/2” 63615-A09-150 6" 152 2 3/8" 60 * * 6" 152 * * 3" 76 3" 76

inpro.com | 800.222.5556obsessed with protecting buildings™ 1312

Page 8: Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

Tacoma Art Gallery | Tacoma, WA501 Pan Floor System, 491 Wall + Ceiling System, Vapor Barrier, F520 Fire Barrier,

611 Exterior System, 616 Exterior System, 651 Roof System, 806 Floor System

Page 9: Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

S

W

H1

11/4

" (32

mm

)

S

W

H1

11/4

"(32

mm

)

SW

H1

300E Series - Glide Plate

Closed/Nominal Position Closed/Nominal PositionOperational Position

Application SystemW1 W2 H1 S1 S2 Thermal Movement +/- Seismic Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Sightline Horiz. Vert. Horiz. Vert.US mm US mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

601-A07/A09-300 12" 305 17 1/2" 445 1 1/2" 38 1 3/16" 30 3 1/16" 78 1" 25 1" 25 6" 152601-A07/A09-450 18" 457 23 1/2" 597 1 1/2" 38 1 3/16" 30 3 1/16" 78 1" 25 1" 25 9" 229601-A07/A09-600 24" 610 29 1/2" 749 1 1/2" 38 1 3/16" 30 3 1/16" 78 1" 25 1" 25 12" 305

System available in any variation of size for 10" (250mm) -36" (750mm) expansion gaps.

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

651-A07-025 1" 25 1 1/4" 32 * * 4 1/4" 108 * * 1/2" 13 1/2" 13651-A07-050 2" 51 1 1/4" 32 * * 5 1/4" 133 * * 1" 25 1" 25651-A07-075 3" 76 1 1/4" 32 * * 6 1/4" 159 * * 1 1/2" 38 1 1/2" 38651-A07-100 4" 102 1 1/4" 32 * * 7 1/4" 184 * * 2" 51 2" 51651-A07-150 6" 152 1 1/4" 32 * * 10 1/2" 267 * * 3" 76 3" 76651-A07-200 8" 203 1 1/4" 32 * * 13 1/2" 343 * * 4" 102 4" 102651-A07-300 12" 305 1 5/16" 33 * * 19 1/2" 495 * * 6" 152 6" 152

Wall to CornerWall to Ceiling

651-A09-025 1" 25 1 1/4" 32 * * 2 5/8" 67 * * 1/2" 13 1/2" 13651-A09-050 2" 51 1 1/4" 32 * * 3 5/8" 92 * * 1" 25 1" 25651-A09-075 3" 76 1 1/4" 32 * * 5" 127 * * 1 1/2" 38 1 1/2" 38651-A09-100 4" 102 1 1/4" 32 * * 6 1/2" 165 * * 2" 51 2" 51651-A09-150 6" 152 1 1/4" 32 * * 9 1/2" 241 * * 3" 76 3" 76651-A09-200 8" 203 1 1/4" 32 * * 12 1/2" 318 * * 4" 102 4" 102

Larger sizes available.

• 5/8" recessed frame designed for inset installations (can be surface mounted as well).

• Snap-fit cover designed for easy on-site assembly, no exposed fasteners make system ideal for public/high abuse conditions.

• Clear anodized finish.• Custom angles available.

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

300E-A07-025 1" 25 5/8" 16 * * 5" 127 2" 51 1/2" 13 1/4" 6300E-A07-050 2" 51 5/8" 16 * * 6" 152 2" 51 1" 25 1/2" 13300E-A07-075 3" 76 5/8" 16 * * 9" 229 3" 76 1 1/2" 38 3/4" 19300E-A07-100 4" 102 5/8" 16 * * 10" 254 3" 76 2" 51 1" 25300E-A07-150 6" 152 5/8" 16 * * 14" 356 4" 102 3" 76 1 1/2" 38300E-A07-200 8" 203 5/8" 16 * * 18" 458 5" 127 4" 102 2" 51300E-A07-250 10" 254 5/8" 16 * * 24" 610 7" 178 5" 127 2 1/2" 64300E-A07-300 12" 305 5/8" 16 * * 26" 661 7" 178 6" 152 3" 76

Wall to CornerWall to Ceiling

300E-A09-025 1" 25 5/8" 16 * * 4 5/8" 117 2" 51 1/4" 6 3/4" 19300E-A09-050 2" 51 5/8" 16 * * 6 1/8" 156 2" 51 1/2" 13 3/4" 19300E-A09-075 3" 76 5/8" 16 * * 8 1/8" 206 3" 76 3/4" 19 7/8" 22300E-A09-100 4" 102 5/8" 16 * * 9 1/8" 232 3" 76 1" 25 1" 25300E-A09-150 6" 152 5/8" 16 * * 12 1/8" 308 4" 102 1 1/2" 38 1 1/4" 32300E-A09-200 8" 203 5/8" 16 * * 15 1/8" 384 5" 127 2" 51 1 1/2" 38300E-A09-250 10" 254 5/8" 16 * * 21 5/8" 549 7" 178 2 1/2" 64 2" 51300E-A09-300 12" 305 5/8" 16 * * 23 5/8" 600 7" 178 3" 76 2 1/2" 64

Metal Wall Systems% of Movement ± 50% | Joint Width 12" (305mm) – 36"(914mm)

• Surface-mount frame accommodates uneven joint widths.

• Rubberized washers prevent the elements from penetrating the cover plate at anchor points.

• Factory formed transitions available.

• Mill finish standard – custom finishes available.

W

S

H1

S

S

H1 H1

H1H1

WW

WW

S S

601 Series - Flush Mount

651 Series - Surface Mount

A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown)

A07 Wall/Wall (2" (51mm) system shown)

A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown)

A09 Wall/Corner (2" (51mm) system shown)

A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown)

S1 S2"A"

"A"

W1

W2

H1

• The Hinged Cover plate or “pan” can be filled with adjacent architectural systems to disguise the expansion joint (glazing, metal panels and the masonry units such as stone and brick).

• Ideal system for high-end exterior systems or conditions where the structural joint is located in a high-profile position on the building veneer.

• Flush-mounted exterior system reduces sightline to two reveals of approximately 1" (25mm) and 3" (76mm) dimensions.

• System is seismic-capable while allowing for daily thermal movement and wind sway.

• Compression spring shock absorption assembly correctly repositions the pan to the normal position after a system movement.

inpro.com | 800.222.5556obsessed with protecting buildings™ 1716

Page 10: Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

w

H1

s

s

w

H1

S

W

H111/4" (32mm)

S

W

H111/4"(32mm)

Metal Roof Systems% of Movement ± 50% | Joint Width 1" (25mm) – 12" (300mm)

• Exterior roof systems available with standard hard-lid aluminum covers.• Moisture barrier included.• Neoprene weather washers prevent leaking where fasteners

penetrate frames/covers.• Mill finish standard.• Factory formed transitions available.

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Roof to Roof

661-A01-025 1" 25 1 1/4" 32 * * 4 1/4" 108 8 3/8" 213 1/2" 13 1/2" 13661-A01-050 2" 51 1 1/4" 32 * * 5 1/4" 133 8 7/8" 225 1" 25 1" 25661-A01-075 3" 76 1 1/4" 32 * * 6 1/4" 159 9 5/8" 244 1 1/2" 38 1 1/2" 38661-A01-100 4" 102 1 1/4" 32 * * 7 1/4" 184 10 5/8" 270 2" 51 2" 51661-A01-150 6" 152 1 1/4" 32 * * 10 1/2" 267 12 1/8" 308 3" 76 3" 76661-A01-200 8" 203 1 1/4" 32 * * 13 1/2" 343 14 1/8" 359 4" 102 4" 102661-A01-300 12" 305 1 3/8" 35 * * 19 1/2" 495 18 1/8" 460 6" 152 6" 152

Roof to Wall

661-A02-025 1" 25 1 1/4" 32 * * 2 5/8" 67 4 5/8" 117 1/2" 13 1/2" 13661-A02-050 2" 51 1 1/4" 32 * * 3 5/8" 92 5 3/8" 137 1" 25 1" 25661-A02-075 3" 76 1 1/4" 32 * * 5" 127 6 3/8" 162 1 1/2" 38 1 1/2" 38661-A02-100 4" 102 1 1/4" 32 * * 6 1/2" 165 7 3/8" 187 2" 51 2" 51661-A02-150 6" 152 1 1/4" 32 * * 9 1/2" 241 9 3/8" 238 3" 76 3" 76661-A02-200 8" 203 1 1/4" 35 * * 12 1/2" 318 11 3/8" 289 4" 102 4" 102

Larger sizes available.

S

H113/8"

(35mm)

W

S

H113/8"

(35mm)

W

• 661 – 45° Curb Mounted.• Frame angled to assist in securing roofing

membrane down on 45° curb.• Moisture barrier included.• Weather washers prevent leaking where

fasteners penetrate frames/covers.• Factory pre-formed transitions available.• Mill finish pre-formed standard.• Custom options available.• Drain tube optional.

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Roof to Roof

651-A01-025 1" 25 1 1/4" 32 * * 4 1/4" 108 * * 1/2" 13 1/2" 13651-A01-050 2" 51 1 1/4" 32 * * 5 1/4" 133 * * 1" 25 1" 25651-A01-075 3" 76 1 1/4" 32 * * 6 1/4" 159 * * 1 1/2" 38 1 1/2" 38651-A01-100 4" 102 1 1/4" 32 * * 7 1/4" 184 * * 2" 51 2" 51651-A01-150 6" 152 1 1/4" 32 * * 10 1/2" 267 * * 3" 76 3" 76651-A01-200 8" 203 1 1/4" 32 * * 13 1/2" 343 * * 4" 102 4" 102651-A01-250 10" 254 1 1/4" 32 * * 16 1/2" 419 * * 5" 127 5" 127651-A01-300 12" 305 1 5/16" 33 * * 19 1/2" 495 * * 6" 152 6" 152651-A01-350 14" 356 1 5/16" 33 * * 22 1/2" 572 * * 7" 178 7" 178651-A01-400 16" 406 1 5/16" 33 * * 25" 635 * * 8" 203 8" 203

Roof to Wall

651-A02-025 1" 25 1 1/4" 32 * * 2 5/8" 67 * * 1/2" 13 1/2" 13651-A02-050 2" 51 1 1/4" 32 * * 3 5/8" 92 * * 1" 25 1" 25651-A02-075 3" 76 1 1/4" 32 * * 5" 127 * * 1 1/2" 38 1 1/2" 38651-A02-100 4" 102 1 1/4" 32 * * 6 1/2" 165 * * 2" 51 2" 51651-A02-150 6" 152 1 1/4" 32 * * 9 1/2" 241 * * 3" 76 3" 76651-A02-200 8" 203 1 1/4" 32 * * 12 1/2" 318 * * 4" 102 4" 102651-A02-250 10" 254 1 1/4" 32 * * 15 1/2" 394 * * 5" 127 5" 127651-A02-300 12" 305 1 5/16" 33 * * 18 1/2" 470 * * 6" 152 6" 152651-A02-350 14" 356 1 5/16" 33 * * 21 1/2" 546 * * 7" 178 7" 178651-A02-400 16" 406 1 5/16" 33 * * 25" 635 * * 8" 203 8" 203

• Easy onsite assembly and installation.• Capable of multi-directional seismic movement.• Moisture barrier included.• Neoprene weather washers prevent leaking where fasteners

penetrate frames/covers.• Surface mount accommodates uneven joint widths.• Factory formed transitions available.

• Mill finish standard.• Plate available in stainless steel.• Versatile frame profile allows for a wide range of building

applications.• ±100% movement available.• High performance Kynar® 500 resin-based coatings optional.

Application SystemW H1 S B Movement +/-

Joint Width Frame Height 1 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm

Roof to Roof

691-A01-025 1" 25 1 1/4" 32 4 1/4" 108 8 3/8" 213 1/2" 13 1/2" 13691-A01-050 2" 51 1 1/4" 32 5 1/4" 133 8 7/8" 225 1" 25 1" 25691-A01-075 3" 76 1 1/4" 32 6 1/4" 159 9 5/8" 244 1 1/2" 38 1 1/2" 38691-A01-100 4" 102 1 1/4" 32 7 1/4" 184 10 5/8" 270 2" 51 2" 51691-A01-150 6" 152 1 1/4" 32 10 1/2" 267 12 1/8" 308 3" 76 3" 76691-A01-200 8" 203 1 1/4" 32 13 1/2" 343 14 1/8" 359 4" 102 4" 102691-A01-300 12" 305 1 3/8" 35 19 1/2" 495 18 1/8" 460 6" 152 6" 152

Roof to Wall

691-A02-025 1" 25 1 1/4" 32 2 5/8" 67 4 5/8" 117 1/2" 13 1/2" 13691-A02-050 2" 51 1 1/4" 32 3 5/8" 92 5 3/8" 137 1" 25 1" 25691-A02-075 3" 76 1 1/4" 32 5" 127 6 3/8" 162 1 1/2" 38 1 1/2" 38691-A02-100 4" 102 1 1/4" 32 6 1/2" 165 7 3/8" 187 2" 51 2" 51691-A02-150 6" 152 1 1/4" 32 9 1/2" 241 9 3/8" 238 3" 76 3" 76691-A02-200 8" 203 1 1/4" 35 12 1/2" 318 11 3/8" 289 4" 102 4" 102

Larger sizes available.

• Easy on-site assembly and installation.• Multi-directional seismic movement.• Moisture barrier included.• Neoprene weather washers prevent

leaking where fasteners penetrate frames/covers.

• 2x wood blocking mount.• Factory formed transitions available.• Cover plate available in stainless steel

or alternate secondary finishes.• Drain tube optional.• Mill finish standard.

651 Series

691 Series - Vertical Curb Mount

661 Series - Curb Mounted Centering Bar

651-A01 Roof/Roof (2" (50mm) system shown)

651-A02 Roof/Wall(2" (50mm) system shown)

661-A02 Roof/Wall(2" (50mm) system shown)

661-A02 Roof/Wall(2" (50mm) system shown)

A01 Roof/Roof (2" (51mm) system shown)

A02 Roof/Wall (2" (51mm) system shown)

H1 H1

H1H1

W W

WW

S

S

S

S

H1H1

W W

SS

13/8"(35mm) 13/8"

(35mm)

inpro.com | 800.222.5556obsessed with protecting buildings™ 1918

Page 11: Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

Metal Roof TransitionsThis is merely a sampling of common transition types encountered in the field. Contact a Inpro Expansion Joint expert for more information regarding your specific transition.

Common Roof TransitionsThis is merely a sampling of common transition types encountered in the field. Contact a Inpro Expansion Joint expert for more information regarding your specific transition.

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

A

B

C

D

E

F

G

H

I

A. Parapet

D. Vertical to Horizontal Roof to Wall

G. "T" Intersection Roof to Wall

B. Roof to Roof

E. Roof to Wall

H. Horizontal to Vertical Roof to Roof

C. Roof to Wall

F. Roof to Wall

I. Horizontal to Vertical Roof to Wall

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

inpro.com | 800.222.5556obsessed with protecting buildings™ 2120

Page 12: Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

W

2"(51mm)

2"(51mm)

W

2"(51mm)

2"(51mm)

W

4”(102mm)

W

4”(102mm)

Application SystemMovement +/-

Horizontal VerticalUS mm US mm

Roof to Roof

672-G01-050 1" 25 1" 25672-G01-075 1 1/2" 38 1 1/2" 38672-G01-100 2" 51 2" 51672-G01-150 3" 76 3" 76672-G01-200 4" 102 4" 102

Roof to Wall

672-G02-050 1" 25 1" 25672-G02-075 1 1/2" 38 1 1/2" 38672-G02-100 2" 51 2" 51672-G02-150 3" 76 3" 76672-G02-200 4" 102 4" 102

Application SystemW Movement +/-

Joint Width Horizontal VerticalUS mm US mm US mm

Roof to Roof

674-G01-050 2" 51 1" 25 1" 25674-G01-075 3" 76 1 1/2" 38 1 1/2" 38674-G01-100 4" 102 2" 51 2" 51674-G01-150 6" 152 3" 76 3" 76674-G01-200 8" 203 4" 102 4" 102

Roof to Wall

674-G02-050 2" 51 1" 25 1" 25674-G02-075 3" 76 1 1/2" 38 1 1/2" 38674-G02-100 4" 102 2" 51 2" 51674-G02-150 6" 152 3" 76 3" 76674-G02-200 8" 203 4" 102 4" 102

Bellows Roof SystemExpansion Joints intersect and change directions. Ensure maximum flexibility, clean lines and waterproofing in these critical areas with the application of factory-formed intersections and transitions.

• Remains watertight during severe seismic movement.• Splicing kits are included for simple installation.• Flanges available standard as galvanized optional stainless steel, copper, aluminum and EPDM.

W

W

W

4"(102mm)

W

674 Series - Bellows/Curb Flange

672 Series - Bellows/Canted Roof

G01 Curb Flange Roof/Roof (2" (51mm) system shown)

G01 Canted Roof/Roof (2" (51mm) system shown)

G02 Curb Flange Roof/Wall (2" (51mm) system shown)

G02 Canted Roof/Wall (2" (51mm) system shown)

Good Samaritan Hospital | Mount Vernon, IL615 Wall System, 616 System

2"(51mm)

2"(51mm)

2"(51mm)

2"(51mm)

obsessed with protecting buildings™ 2322

Page 13: Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

Bellows Roof TransitionsThis is merely a sampling of common transition types encountered in the field. Contact a Inpro Expansion Joint expert for more information regarding your specific transition.

A. Parapet

D. Vertical to Horizontal Roof to Wall

G. "T" Intersection Roof to Wall

B. Roof to Roof

E. Roof to Wall

H. Horizontal to Vertical Roof to Roof

C. Roof to Wall

F. Roof to Wall

I. Horizontal to Vertical Roof to Wall

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

H

F

E

D

B

C

G

H

F

E

D

B

C

G

II

A A

Oregon Health & Science University | Portland, Oregon F520 Blanket, 200 Series System, 223 Floor Series System, 600 Series System, 616 Wall Series System (Shown),

651 Roof with Insulated Moisture Barrier, Insulated Moisture Barrier System

inpro.com | 800.222.5556obsessed with protecting buildings™ 2524

Page 14: Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

Owensboro Medical Center Owensboro, KY

Parkland Hospital Dallas, TX

Abraham Lincoln High School San Fransisco, CA

Dufur School Dufur, OR

Sierra Vista Middle School La Puente, CA

Chemawa Indian School Salem, OR

Jefferson Elementary School West Allis, WI

BSU Student Union Transit Center Boise, ID

Seattle University Fitness Center Seattle, WA

Pima Community College Tuscon, AZ

Purdue Honors College West Lafayette, IN

Santa Clara Univ Phase 2 Student Residence Santa Clara, CA

St. Louis University Residence Hall St. Louis, MO

Texas City High School Texas City, TX

Waikiki Shopping Plaza Honolulu, HI

Maui Lani Shopping Center Wailuku, HI

Three Rivers Mall Regal Theater Connection Kelso, WA

Harley Davidson of Scottsdale Scottsdale, AZ

Rusnak MB Arcadia Mercedes-Benz Arcadia, CA

Palos Verde Senior Living Peoria, AZ

Oakmont Senior Housing Windsor, CA

Forest park Middle School Franklin, WI

Shinola Hotel Detroit, MI

Wrigley Field renovations Chicago, IL

Hamilton Sussex intermediate school Sussex, WI

Austin Bergstrom International Airport (ABIA) Austin, TX

Silver Spot movie theater Brookfield, WI

Salt Lake County Office Building and Parking Structure Salt Lake City, UT

The District at Milpitas Milpitas, CA

Stanford at Redwood City

Tacoma Art Museum Tacoma, WA

Santa Clara Square Santa Clara, CA

AVA at Esterra Park Redmond, WA

Jefferson Stadium Park Apartments Anaheim, CA

UC San Diego Osler Parking La Jolla, CA

Idaho National Lab Idaho Falls, ID

ICD Brookfield Place Dubai, UAE

Nshama Town Square Development Dubai, UAE

UW PlattevillePlatteville, WI

Yas MallAbu Dhabi, UAE

CLSB - OHSU Life Sciences Portland, OR

Anchorage Museum Phase 2 Anchorage, AK

Weld County Courts Greeley, CO

BCT-H Barracks Complex Fort Carson, CO

LA Coroners Office Los Angeles, CA

McCully District Park Honolulu, HI

Richmond Masonic Temple Richmond, VA

Lake Oswego Water Treatment Plant Portland, OR

Yakama Nation Casino-Exteriors Toppenish, WA

Cinemark Movie Theater North Haven, CT

Kirkwood Public Library Kirkwood, MO

Village of Paletine Police Department Palatine, IL

Rock County Jail Janesville, WI

Milwaukee Art Museum Milwaukee, WI

OK State Fairgrounds Expo Center Oklahoma City, OK

Jeanne Bellamah Comm Center Albuquerque, NM

Cross Point Church Oconomowoc, WI

River Spirit Casino Tulsa, OK

Google Tech Corners Bldgs Sunnyvale, CA

Boys & Girls Club @ Shoreline Santa Cruz, CA

Pensacola Regional Airport Pensacola, FL

Jackson Hole Airport Baggage Claim Jackson Hole, WY

SDIA Rental Car San Diego, CA

Lambert Airport Terminal 1 Baggage St. Louis, MO

Delta Airlines Lobby / ATO Renovation Sea Tac Airport Seattle, WA

St. Mary's Hospital Century Project Grand Junction, CO

Las Vegas VA Hospital Las Vegas, NV

SUMC Nuclear Medicine Dept Standford, CA

Rocky Mtn Hospital for Children Denver, CO

Moab Regional Medical Center Moab, UT

UNMH Clinical Neuroscience Center Albuquerque, NM

Alaska Regional Hospital Anchorage, AK

Community Hospital of Grand Junction Grand Junction, CO

Rush University Medical Center Chicago, IL

Hospital Expansion & Renovation Laurium, MI

Biloxi VA Mental Health Biloxi, VA

Jennie Sealy Galveston, TX

Mercy Cancer Center Joplin, MO

Cleveland Clinic Abu Dhabi, UAE

World Trade CenterNew York City, NY

SunTrust StadiumAtlanta, GA

Milwaukee Mitchell AirportMilwaukee, WI

College of San MateoSan Mateo, CA

MGM National Harbor Oxon Hill, MD

Citrus Bowl Orlando, FL

Recent ProjectsThe list below is a sample of projects we’ve completed across the globe. For more information or detailed project profiles, visit inpro.com/jointmaster.

inpro.com | 800.222.5556obsessed with protecting buildings™ 2726

Page 15: Exterior Expansion Joint Systems · 2020-04-21 · Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint

obsessed with protecting buildings®

How they look. How they function. And how they protect the health and safety of the people who use them every day.

That’s why we make hundreds of architectural products all under one roof and work tirelessly to make sure you and your buildings succeed.

Yeah, we are obsessed. But we wouldn’t have it any other way.

inpro.com

800.222.5556World Headquarters S80 W18766 Apollo DriveMuskego, WI 53150 USA

IPC® Door + Wall ProtectionAscend® Elevator ProtectionJuniper® Commercial Window TreatmentsClickeze® Privacy SystemsEndurant® Washroom SystemsSignScape® Architectural SignageJointMaster® Expansion Joint Systems

©2019 Inpro Corporation

inpro.com | 800.222.5556