Slope 1:50 168 196 1 96 Sliding door at Entrance of Builing povided , In accordance with TGD L CHS Column, holidng external canopy in place, bolted on base plate Canopy glass 24mm fixed on with bolts Steel beam/outridge allowing glass o be fixed to and providing shelter Aluminium pressed flashing , fixed to curtain box allowing rain to be drained off Drain pipe Sliding door head detail automatic sensor openings Propriatry drainage channel, external treshold detail Sprandel panel Curtain walling box Structural screed 75mm to Engineers specification PI Rigid Ins thermal conductivity: 0.025W/mK DPM/Radon barrier Hollowcore floor 200mm CHS Column supporting curtain walling boxes Intermideate beam/truss supporing lateral loads Bracket fixing tying curtain walling box to CHS column CHS Column supporting curtain walling boxes Intermideate beam/truss supporing lateral loads Bracket fixing tying curtain walling box to CHS column BASE plate column connection Rain wate gutter Scale LECTURER Drawn by Date Project number Institute of Technology Carlow BSc. in Architectural Technology Year 3 2015-2016 BSc in Architectural Technology Year 3: 2015 - 2016 1 : 5 19/04/2016 18:10:02 External Canopy & Entrance Project Number 3 Carlow Primary Health Care Centre 22/04/2016 Xhevdet Haliti Dan O'Sullivan, Noel Dunne, Mark Duffy A127 1 : 5 External enterance Treshold & Enterance G.F Detail 1 3D - External entrance & canopy 2 1 : 5 Key Plan @ Enterance & Canopy 3 D C 9

Extenal Canopy & Entrance

Embed Size (px)

Citation preview

Page 1: Extenal Canopy & Entrance

Slope 1:50

168

196

196

Sliding door at Entranceof Builing povided , Inaccordance with TGD L

CHS Column, holidngexternal canopy in place,bolted on base plate

Canopy glass 24mmfixed on with bolts

Steel beam/outridgeallowing glass o be fixedto and providing shelter

Aluminium pressedflashing , fixed tocurtain box allowingrain to be drained off

Drain pipe

Sliding door head detailautomatic sensor openings

Propriatry drainagechannel, externaltreshold detail

Sprandel panel

Curtain walling box

Structural screed75mm to Engineersspecification

PI Rigid Insthermal conductivity:0.025W/mK

DPM/Radon barrier

Hollowcore floor 200mm

CHS Columnsupporting curtain wallingboxes

Intermideate beam/trusssupporing lateral loads

Bracket fixingtying curtain walling boxto CHS column

CHS Columnsupporting curtain wallingboxes

Intermideate beam/trusssupporing lateral loads

Bracket fixingtying curtain walling boxto CHS column

BASE plate columnconnection

Rain wate gutter

Scale

LECTURER

Drawn by

Date

Project number

Institute of Technology CarlowBSc. in Architectural Technology

Year 3 2015-2016

BSc in Architectural Technology Year 3: 2015 - 2016

1 : 5

19/0

4/20

16 1

8:10

:02

External Canopy & Entrance

Project Number 3

Carlow Primary Health Care Centre

22/04/2016

Xhevdet Haliti

Dan O'Sullivan, Noel Dunne,Mark Duffy

A127

1 : 5External enterance Treshold & Enterance G.F Detail

1

3D - External entrance & canopy2

1 : 5Key Plan @ Enterance & Canopy

3

D C

9