EXPERT REPORT OF DR FREDERICK GENE BECK
Weatherford
REVISION A.2
DATE 1/25/2011
DOCUMENT No 0000446283
M45AP Flow-Activited Mid-Bore Auto-F1H Float Collar
NON-ROTATNGWIPERLOK
LANDING PLATE
AUTO-FILL TUBE
ASSEMBLY
NIGH DENSI1Y
3.4 SG 2.0 ODPHENOLIC BALL
235ID597 mm
45 368 mm diameter clearance
between lugs to catch .625W 41.25
mm diameter balls from above
CONCRETE
UPPER VALVEASSEMBLY
Aluminum
2.5OTubeOD
E3.S mm
219 Tube ID556 mm
LOWER VALVEASSEMBLY
Aluminum
FLOWPORTS2
1.93 49 mm BALLSEATP.D
Figure 11 Weatherford M45AP Float Collar Used In Macondo Well97
The Weatherford M45AP is an auto-fill type float collar Auto-fill
means that the check valve feature of the collar is held open while running
in the hole to automatically fill up the casing and to prevent increasing the
pressure on the formations to be cemented called surging the formation
which could fracture the formation and prematurely cause hydrocarbon
kick or lost circulation The Weatherford M45AP float collar used by BP
has phenolic resin auto-fill tube that holds two aluminum flapper-type
check valves in an open position Inside the auto-fill tube is high density
ball that is held in place at the top by three fingers and on the bottom by
Depo Ex 2582 at WFT-MDL00020470