The WL40F Series arelow-electric-power wireless
devices that requires No License.
Wireless MakesWireless Makes
Utility Facilities Monitoring Easy!Utility Facilities Monitoring Easy!
Central monitoring room
PC / SCADA
Web Data LoggerDL30
Web(Internet)
SmartphoneTablet
Modbus/TCP
Router
Parent900 MHz ISM Band 900 MHz ISM Band
Cen
tral
ized
mon
itorin
g of
util
ity fa
cilit
ies
Application examples
Compressor
Child
Pump flow rate
GasDemineralized waterFuelChillerBoiler
Wastewater/ Waste fluids
Child
pH meter
Air conditioning
Child
Exhaust gas
Child
Power equipment
Child
ChildChildChild
Additional isolated signal channel to the existing installation
Signal Splitters
Existing equipment
Isol
atio
n
4–20 mA DC
4–20 mA DC
Input Circuit
Signal SplitterSignal Splitter
Sensor
AfterAfter
4–20 mA DC 4–20 mA DC
Sensor
Recorder
Expandable, Compact Remote I/O R7M Series ⑥
■ Supporting the industrial standard Modbus-RTU open network
■ All-in-one style compact modules can handle 4 analog input, 2 analog output or 16 discrete signals.
■ 8 or 16 discrete input/output module can be attached to the base module■ Wide variety of I/O signals available■ 1500 V AC isolation
115 mm (4.53 in) 54 mm
(2.13 in)
50 m
m
(1.9
7 in
)
BeforeAdditional Output
No change!No change!
• Available for selected models
Basic module 17 models
Extension module 8 models
29.5 mm(1.16 in)
(4.49 in
)
(1.61 in)
114 mm
Compact, plug-in socket mounted
W2 Series (Mini-MW)
The socket mounted signal conditioner modules can be removed, tested and replaced without disconnecting wiring.Once plugged in, they are securely fastened with the front screw to the socket.
The W2 Series (Mini-MW) Dual Output Signal Conditioners features a wide range of input and output signals.
27models
Low-profile, terminal block style
W5 Series
Only 41 mm (1.61 in) deep, terminal block style modules can be installed anywhere, even behind the panel cover.
The W5 Series Dual Output Signal Conditioners are designed with the minimum required number of carefully selected components to ensure outstanding economy.
8 models
Dual OutputSpace-saving
45 mm (1.77 in)
41mm
Dual OutputTerminal Block
Child
16
Child
Child
WL40F Series
WL40F Series
900 MHz ISM BandMulti-hop
Wireless System
The use of wireless communication equipment requires approval on a country-by-country basis. The WL40F Series products are usable only in the US.
The use of wireless communication equipment requires approval on a country-by-country basis. The WL40F Series products are usable only in the US.
Quick Installation!
2018-08EC-Z670
4-2007
Rev. 001
Existing equipment
www.m-system.com
No license application or renewal fees.Free to use!
An isolated output signal can be added safely for IoT-applied remote control and centralized monitoring purposes.
500548
Advantages of using the WL40F Series for the centralized monitoring of utility facilities
3
2
4
Low installation cost
Reasonable unit cost Easy system modification and expansion
+Newly addedExisting
Well, considering all the work needed
to add only one measuring point...
2 3
Material and cableenbedding work cost
ISP
Mobile Line
IoTIoT Internet
Mail Smartphone
Tablet Laptop PC
Onsite
Plant
Control rooms
Management rooms
Remote locations
Wireless I/O
Remote I/OR7 Series
Wireless gateway
Wireless gateway
1 km max.(0.62 mi)
1 km max.(0.62 mi)
1 km max.(0.62 mi)
1 km max.(0.62 mi)
I/O I/O
I/O
Plant Manager’s office
Guardhouse Central control room
Web Data LoggerDL8
Web Data LoggerDL30
Tablet RecorderTR30-G
See ③
Page 5
See ②
Page 5
See ②Page 5
See ②Page 5
See ②Page 5
See ②Page 5
See ⑥Page 16
See ④
Page 5
See ⑤
Page 5
Utility equipment A Utility equipment B
Utility equipment C
PCs, tablets, and smartphones with browser software can be used.
Trend graph screen example
Report form example
Repeater(Child)
Com
man
d/R
espo
nse
data
Command/Response data
Modbus/TCP
900 MHz ISM BandMulti-hop
Wireless System
Factories, hospitals, schools, and many other entities throughout the United States have utility facilities that are in operation at all times. Such utility facilities include power, gas, boiler, and compressor equipment as well as pumping equipment for groundwater and wastewater treatment equipment. They play important roles in most sites. Nevertheless, many of them are maintained in conventional “manual” methods because they have not been considered as a subject for centralized monitoring.
M-System has released the WL40F Series 900 MHz Band Multi-hop Wireless System as a means to easily and inexpensively realize centralized monitoring of utility facilities . The FCC Part 15 compliant low-electric-power wireless devices require no licence for use in the United States.
Furthermore, for the effective use of the WL40F Series, M-System offers the DL8 Web Data Logger and the TR30-G Tablet Recorder , which can be connected direct to the Internet, as well as the DL30 Web Data Logger , which can be installed onsite for use with ease.
M-System has summarized application examples of these radio applications so that everyone in charge of facility maintenance may use them. These are a few examples of installations that M-System has delivered using the above products.
Recommendation for Wireless Monitoring of Utility Facilities Con�guration Example of M-System’s Wireless System
Introduction
1 Short installation work period
PCs with browser software can be used.
Wireless I/O
The user can collect monitoring data of a factory's utility facilities from remote locations such as the headquarters and
branch offices. The system can send e-mails to report abnormal or failures to
the user's smartphone.
Each child station takes in signals according to the commands from the master unit
and transmits data to the parent station.
I can monitor the status of utility facilities in my office.
Modbus-RTU
Modbus/TCP Master UnitsThe master unit transmits cyclic commands to the slave units
through the WL40F Series parent station and collects responses from slave units.
ISP
Router
Use another child station as a repeater if the communications distance
is long or if there is an obstacle.
Just install one Child unit in the desired place.
It’s also easy to change the location
afterwards.
Wireless system cost is much lower simply
because there is no signal line wiring.
The use of wireless communication equipment requires approval on a country-by-country basis. The WL40F Series products are usable only in the US. The use of wireless communication equipment requires approval on a country-by-country basis. The WL40F Series products are usable only in the US.
Parent
Child
Child
Parent Child Child
Shigeru Miyamichi
M-System Co., Ltd.
Chairman of the Board
WL40F Series
WL40F Series
WL40F Series
What about the total running cost of a wireless system?
see ①: Page 4 and ②: Page 5
see ③: Page 5 see ④: Page 5
see ⑤: Page 5
Wireless I/O
WL40F SeriesFCC Part 15 compliant
FCC Part 15 compliant
Child
WL40F SeriesFCC Part 15 compliant
FCC Part 15 compliant
FCC Part 15 compliant
No opening in schedule for wiring work.
A wireless system needs no pit digging or
cable laying work, realizing a drastically shortened
installation period with a simple work plan.
The parent station transmits
commands from the Modbus master unit to the slave station and responds
from the slaves to the master.
Terminology in this Brochure: “Parent” and “Child” mean “Wireless Master” and “Wireless Slave” stations respectively, whereas “Master” and “Slave” mean “Modbus Master” and “Modbus Slave”.
The WL40F Series 900 MHz Band Multi-hop Wireless
System needs no radio license, no license application fee, and no
monthly communications charge.
We want to add more monitoring
points but work costs are surprisingly
high.
Introduction of 900 MHz band wireless products
900 MHz ISM Band Multi-hop Wireless System
What is 900 MHz band wireless communication?
What is multi-hop technology?
Communications path
Modbus/TCP Modbus/TCP
Automatically switched to an alternative path
An initial power level of 20 mW will be attenuated more and more as a result of path loss over a large area.
With consideration of the propagation environment,
the rated maximum inter-station transmission distance is set to 0.62 miles (1 km).
According to the graph of Distance vs. Reception Level on the right-hand side,
the communications distance should be several thousand meters at a level of -85 dBm.
However, this is a theoretical value.
As shown in table 1, the rated reception sensitivity limit of
the WL40F Series is -90 dBm.
With a margin of three times taken into
account, the practical reception sensitivity limit is considered
to -85 dBm.
Reference: A level of -90 dBm is equivalent to 1 pW based on a level of 0 dBm as 1 mW.
Transmission Distance
① ②
Modbus/TCP master units to be combined with WL40F Series
③Web Data Logger
Model: DL8
The Web Data Logger is an Internet-of-things (IoT) terminal incorporating versatile functions, including a remote monitoring function, data logging function, and event reporting function, available through a website screen.
Basic functions• Simple web server
(e.g., for a trend screen)• Data logging• Email function• FTP function• Modbus/TCP
communications function
④Tablet Recorder
Model: TR30-G
The Tablet Recorder is a data recorder that displays collected and accumulated trend data on a website screen using a tablet or PC via an IP network, such as a Wi-Fi network.
Basic functions• Trend data/Event data recording• Simple web server
(e.g., for a trend screen)• Email function• FTP function• Modbus/TCP
communications function• Various calculation inputs
⑤Web Data Logger
Model: DL30 - JAPANESE VERSION ONLY
The Web Data Logger is a data logger of onsite-installation type incorporating versatile functions, including a remote monitoring function, data logging function, and event reporting function, available through a website screen as well as a report creation function.
Basic functions• Simple web server (e.g., for a trend screen)• Data logging• Email function• FTP function• Modbus/TCP communications function• PLC communications function• Report (daily, monthly, and annual
report) creation function• Various calculation inputs• Scheduling
For details, see the website of M-System.
The WL40F Series Wireless I/O System employs a licence-free 900 MHz ISM band module. Compared with 2.4 GHz band and 5 GHz band wireless LANs and wireless networks for instrumentation that use higher frequency bands, the 900 MHz band ensures stable communication quality and a long communications distance. It does not require license registration, and unlike mobile communications, users do not need to pay telecommunications charges to telecommunications service provider. Therefore, the 900 MHz band is ideal in terms of operating cost as well.
Multi-hop wireless communication is a wireless network conveying data through a number of wireless communication devices in a “bucket-brigade” manner.Relaying paths are automatically switched to an alternative one when one section of the connection is weak.In the WL40F Series, up to 100 child stations connect to asingle parent station. The communications distance between stations can be up to 0.62 miles (1 km), thus making it possible to construct a wireless network in a wide range.
Power Level Changes in Radio Channel
Distance vs. Reception Level (Free space propagation loss)
4 5
Weak connection
The use of wireless communication equipment requires approval on a country-by-country basis. The WL40F Series products are usable only in the US.
The use of wireless communication equipment requires approval on a country-by-country basis.
The pictures except for tower lights and multiport/wireless gateways show the rooftop antenna types. Sleeve antenna types are also available.
Wireless GatewayModel: WL40EW2F Model: WL40W1F
Wireless I/OWireless GatewayModel: WL40MW1F
Parent
Parent
Child• Modbus-RTU transparent • Modbus-RTU transparent • 2 × Di, 2 × Do
• 2 × 4-20 mA input with excitation supply
What is 900 MHz band wireless communication
Parent Parent
Child
Child
Child
Child
Child
Child
Child
Child
WL40F Series
Radio wave test
Required before introducing the system.
Pow
er le
vel [
dBm
]
Antenna gain
+2.0 dB
Antenna gain
+2.0 dB
Loss-0.5 dB
Loss-0.5 dB
−85 dBm−86.5 dBm
−90 dBm
Radio output
Antenna output
Antenna input
Distance between antennas
−85 dBm
Radio input
Reception sensitivity
Margin
20 mW+13 dBm
−90 dBm
Table 1
20 mW
-90 dBm
Equivalent to 13 dBm
PER (*1) = 10 %
Path loss
(*1) Packet Error Rate
Remarks
Transmission output
Receiving sensitivity
Performance
0
−20
−40
−60
−80
−1000.1 1 10 100
Distance between antennas [m (yd)]
1000 10000(0.11) (1.09) (10.93) (109.03) (1093.61) (10936.13)
−85 dBm
Reception levelReception level
Pow
er le
vel [
dBm
]
FCC Part 15 compliant 900 MHz band products — for use in the US
920 MHz band products — for use in Japan — available in different styles
The pictures show the rooftop antenna types. Sleeve antenna types are also available.
Child
Wireless Gateway
Wireless I/O• Modbus-RTU transparent
Multiport Gateway / Wireless Gateway• Multiport type for 920 MHz+ WiFi access point
• IP67
Tower Light• IP65
• I/O mapping function
Wireless Gateway
Wireless I/O• Modbus-RTU transparent
• 2 × Di, 2 x Do• 2 × 4-20 mA input with excitation supply• 1 × universal input, 1 × pulse input, 1 × Do• Multi-power transducer
Plug-in Wireless I/O• Modbus interface• 4 × clamp-on current sensor input• 2 × universal input
R3 Series Multi-channel Remote I/O• 920 MHz + Modbus interface module• 920 MHz interface module
Tower Light• Modbus interface• IP65
Wireless Gateway• Modbus interface• IP67
After AfterAfter
Explosion-proof areaExplosion-proof area
After
AfterAfter
Noise on signal line
Factory substation
Approx. 1 km (0.62 mi) Monitoring room
Monitoring roomMonitoring room
Monitoring room
• Motor current of hydraulic equipment
• Filter clog alarm
• Motor current of hydraulic equipment
• Filter clog alarm
DL8
PC
Approx. 100 m (109 yd)
BeforeBefore
AfterAfter
After
After
After
Coal loading crane
• Measuring signals of wastewater treatment facilities
• Measuring signals of wastewater treatment facilities
No need of special wiring work
or approval procedures for a wireless system.
Wastewater treatment facilities Tank yard
Monitoring room
In order to add monitoring points, wiring
must cross an explosion-proof area.
DL8
Automatic monitoring
Power monitoring
• Operating status of cooling tower
• Operating status of cooling tower
TR30-G
Tablet
Monitoring room
Textile, Pulp & Paper, Chemical, Petroleum,Rubber, and Ceramic Industries
• Interface meter• Motor current• Interface meter• Motor current
Clarifier
No worrying of contact failures!
Before Before
High-elevation onsite work is a risk.
Before
• Current• Vibration• Current• Vibration
• Power measurement• Power measurement
Remote I/OR9 Series
Work plan
Quotation
The WL40F Series is perfect for cranes. No cable work, and low installation cost.
PC
PC
PCPC
Wi-FiRouter
Parent Parent
Parent Parent
Parent
Child ChildChild
Child
Child
Child
DL8
DL8
The use of wireless communication equipment requires approval on a country-by-country basis. The WL40F Series products are usable only in the US. The use of wireless communication equipment requires approval on a country-by-country basis. The WL40F Series products are usable only in the US.
Too much noise on slip ring signals, a lot of contact failures....
Wireless system is ideal for moving and rotating
equipment.
DL8
PC
Parent
900 MHz ISM Band Multi-hop Wireless System
WL40F SeriesWL40F!
Work period
Work cost
APPLICATIONEXAMPLES
BYINDUSTRIES
We cannot conduct necessary work in a
high place.
Power monitoring is essential for energy
savings, but has considerable cost and time...
Work cost for a wireless system is within
our budget and we can also save the work time.
Wireless remote monitoring can assure safety. I can check the
operating status anywhere with my tablet.
Remote monitoring of wastewater treatment facilities
Remote monitoring of wastewater treatment facilities
Industry: Chemical fiber − Application: DrainageIndustry: Chemical fiber − Application: Drainage
Collection of clari�er dataCollection of clari�er data
Industry: Pulp & paper − Application: DrainageIndustry: Pulp & paper − Application: Drainage
Wiring work passing through hazardous area
Wiring work passing through hazardous area
Industry: Petroleum − Application: FuelIndustry: Petroleum − Application: Fuel
Power monitoring of plant substationPower monitoring of plant substation
Industry: Chemical − Application: PowerIndustry: Chemical − Application: Power
Predictive maintenance ofmoving machines
Predictive maintenance ofmoving machines
Industry: Ceramic industry − Application: TransportIndustry: Ceramic industry − Application: Transport
Remote monitoring of cooling towersRemote monitoring of cooling towers
Industry: Rubber − Application: Air conditioningIndustry: Rubber − Application: Air conditioning
It’s hard to visit the equipment 1 km (0.62 mi)
away twice a day.
Wireless remote monitoring has saved
wiring work and running costs.
Before BeforeBefore
6 7
AfterAfter
• Water intake• Drainage• Water intake• Drainage
Office
We need automatic data logging and
daily/monthly reporting.
WellDrain outlet
Before
After
After
Using the pre-formatted reporting
function is easy.
• Water quality meter
• Water quality meter
Abandoned pit water treatment plant
Abandoned mine site
Monitoring room
Before
Automatic logging
The site is too far away from the
building for hardwire connection.
Before
DL8
Wireless system needs no signal
wiring work.
DL30
PC PC
Parent Parent
Child Child
The use of wireless communication equipment requires approval on a country-by-country basis. The WL40F Series products are usable only in the US. The use of wireless communication equipment requires approval on a country-by-country basis. The WL40F Series products are usable only in the US.
Agriculture, Forestry, Fishery, Mining, Food, Pharmaceutical,Steel, and Nonferrous Metal & Metal Products Industries
So much trouble to go around and collect
data manually.
900 MHz ISM Band Multi-hop Wireless System
WL40F SeriesWL40F!
APPLICATIONEXAMPLES
BYINDUSTRIES
Flow rate monitoring of drainage and groundwater pumps
Flow rate monitoring of drainage and groundwater pumps
Industry: Agriculture, forestry, and fisheries − Application: DrainageIndustry: Agriculture, forestry, and fisheries − Application: Drainage
Water quality management of abandoned mine site
Water quality management of abandoned mine site
Industry: Mining − Application: DrainageIndustry: Mining − Application: Drainage
Remote monitoring of intake well and demineralizer
Remote monitoring of intake well and demineralizer
Industry: Food − Application: Demineralized waterIndustry: Food − Application: Demineralized water
Centralized monitoring of vibration data on motors and conveyers
Centralized monitoring of vibration data on motors and conveyers
Industry: Iron steel − Application: TransportIndustry: Iron steel − Application: Transport
Patrol check on the pressure data of each room
Patrol check on the pressure data of each room
Industry: Pharmaceutical products− Application: Air conditioningIndustry: Pharmaceutical products− Application: Air conditioning
Monitoring of air piping end pressuresMonitoring of air piping end pressures
Industry: Nonferrous metals/Metal products − Application: CompressorIndustry: Nonferrous metals/Metal products − Application: Compressor
After
900 MHz Band
WL40F Series
After• Demineralizer
measurement data, water level, and flow rate
• Demineralizer measurement data, water level, and flow rate
Office
Well 1
Well 2
Demineralizer
A pre-introduction test proved WL40F Series
easily reaches all the sites.
We tried on the 2.4 GHz band but most points
are too far away.
Before
PC
Office
Monitoring of output end pressures
PIA
Plant A
PIA
PIA
Plant B
PIA
PIA
Plant C
COMP
COMP
COMP
COMP
COMP
COMP
• Pneumatic pressure• Start • Stop
• Pneumatic pressure• Start • Stop Child
ChildChild Child
PIA
AfterMonitoring end pressure is important but wiring work for a remote monitoring system is too
expensive.
Thanks to the wireless network, we
can realize the remote monitoring at a
low budget.
Before
PC
After
Control room
• Vibration meter• Vibration meter
Motors
Rollers Added in several phases.
First-phaseSecond-phase
•••
Work plan
After
Expansion is simple by
adding slave stations step by step.
Planning for wiring of over 300
measurement points gives me a
headache.Before
PC
• Atmospheric pressure
• Atmospheric pressure
Monitoring room
DL30
After
Filling room Packing room
Before
Every hour!
AfterTiresome work of going in and out of
each room every hour for just checking pressure
data.Before
The Web Data Logger automatically stores data.
I can check them in my office.
PC
Child
Child Child
Child
Parent
Parent
ParentDL8
DL8
DL8
Parent
Wireless LAN2.4 GHz band
COMP: Compressor; PIA = Pressure indicating alarm
8 9
Power monitoring of precision parts companyPower monitoring of precision parts company
Industry: Precision machinery − Application: PowerIndustry: Precision machinery − Application: Power
Monitoring wastewater from bearing factoryMonitoring wastewater from bearing factory
Industry: Machinery − Application: DrainageIndustry: Machinery − Application: Drainage
Water level monitoring of powerplant’s demineralized water tankWater level monitoring of powerplant’s demineralized water tank
Industry: Power − Application: Demineralized waterIndustry: Power − Application: Demineralized water
Utility management ofprinting/binding companies
Utility management ofprinting/binding companies
Industry: Manufacturing industry − Application: Air conditioningIndustry: Manufacturing industry − Application: Air conditioning
Water leakage monitoring of data centerWater leakage monitoring of data center
Industry: Communication − Application: Air conditioningIndustry: Communication − Application: Air conditioning
Gas �ow rate monitoring of semiconductor factory
Gas �ow rate monitoring of semiconductor factory
Industry: Electrical equipment − Application: GasIndustry: Electrical equipment − Application: Gas
After
Thanks to the wireless system,
we can install water leakage sensors
anywhere with ease.
After
Air-conditioning piping Air conditioner
• Leak sensor• Leak sensor
Water leakage sensor
Monitoring room
Before
Water leakage sensor
PC
Monitoring room
DL8 DL8After
• Oil slick detection sensor
• Oil slick detection sensor
Oil slick detection
sensor
Oil slick detection
sensor
Oil slick detection
sensor
Reservoir Visual check
Approx. 500 m(550 yd)
Before
Gate control
Drainage gate control
panel
No oil slick!
AfterThe wireless thermometers in use have been discontinued.
DiscontinuedDiscontinuedDiscontinued
• Temperature and pH
• Temperature and pH
After
Before
AfterAutomatic monitoring
Long distance transmission is
achieved thanks to the multi-hop capability.
• Power consumption of press machines
• Power consumption of press machines
DL30
After
Before
PC PC
Gas flow meterGas flow meterGas flow meter
Monitoring room
No.1No.2No.3No.4No.20
Before
After• Gas flow meter• Gas flow meter
PC
PC
AfterWe have to modify the existing cable
layout if we want to install a new tank.
No additional cable is needed,
and the tank position can be freely selected.
Monitoring room
BeforeEmbedded cables
After
• Tank level• Tank level
Before
New tank
Existing tank
PC
Parent Parent Parent Parent
Parent Parent
Child Child Child Child
Child ChildDL8 DL8
DL30
Temperature AND pH monitoring utilizing a wireless connection.
The use of wireless communication equipment requires approval on a country-by-country basis. The WL40F Series products are usable only in the US. The use of wireless communication equipment requires approval on a country-by-country basis. The WL40F Series products are usable only in the US.
A sensor and a wireless I/O module
makes it possible to monitor the oil slick remotely.
AfterAutomatic
logging
Web-based data logger plus wireless
network is so convenient!
AfterSo much trouble
to go around 20 places and collect data manually.
Before
The reservoir is about 500 m (550 yds) away.
Before
Press machines are scattered throughout the plant and laying wires
is not an easy task.
We want to monitor water leakage but it's
impossible to add new wiring at this stage.
Machinery, Electrical Equipment, Precision Equipment, Other Manufacturing, Telecommunications, and Power Industries
APPLICATIONEXAMPLES
BYINDUSTRIES
900 MHz ISM Band Multi-hop Wireless System
WL40F SeriesWL40F!
10 11
The use of wireless communication equipment requires approval on a country-by-country basis. The WL40F Series products are usable only in the US. The use of wireless communication equipment requires approval on a country-by-country basis. The WL40F Series products are usable only in the US.
No parts! No forklifts!No parts! No forklifts!No parts! No forklifts!
Remote monitoring of car washing machinesRemote monitoring of car washing machines
Industry: Railroad/Bus − Application: FacilitiesIndustry: Railroad/Bus − Application: Facilities
Predictive and preventive conveyor maintenance
Predictive and preventive conveyor maintenance
Industry: Transportation equipment − Application: TransportIndustry: Transportation equipment − Application: Transport
Radio paging of forkliftsRadio paging of forklifts
Industry: Automobile − Application: TransferIndustry: Automobile − Application: Transfer
Detergent low level!
Error → Stop
After
We can predict and prevent errors by remote
monitoring and shortened the maintenance time.
Once the car wash machine stops because
of low detergent level, it affects the whole maintenance
scheduling.
After
Administration building
Vehicle washing machine
Before
• Remaining detergent• Vibration etc.
• Remaining detergent• Vibration etc.
DL8
AfterWe want to send a call signal for replenishing
parts to the forklift standing by.
The forklift operator can see at a glance
which parts are needed.
After
Once the car wash machine stops because of low detergent level, it affects the whole Once the car wash machine stops because of low detergent level, it affects the whole
Round trip to the warehouse
Forklift
Workplace
With Tower Light (*) With Tower Light (*)
Before
Welding gas
After After
Regulations
Laying new cables
Before
Control room
DL8
• Opening/Closing control signal• Limit switch
• Opening/Closing control signal• Limit switch
InternetInternetSmartphone
Shipyard
Mobile router
• Remaining gasvolume
• Remaining gasvolume After
After
Before
Automatic collection
AfterVisiting each stacker
crane regularly to check its operating status to gather
maintenance data takes a lot of my time.
Manager office
• Vibration• Travel distance• Vibration• Travel distance
• Anemometer• Anemometer
Manager office
AfterAfter
Before
PC
PC
PCPC
Parent
ChildChild Child Child
Child Child
Parent
Parent
Parent
ParentParent DL8 DL8
DL8
Each button (light) identifies a specific part.
DL8
Anemometer data management in the of�ceAnemometer data management in the of�ce
Industry: Shipping − Application: TransportIndustry: Shipping − Application: Transport
Opening and closing of large hanger doorsOpening and closing of large hanger doors
Industry: Air transport − Application: WarehouseIndustry: Air transport − Application: Warehouse
Remaining level monitoring of gas bottlesRemaining level monitoring of gas bottles
Industry: Shipbuilding − Application: GasIndustry: Shipbuilding − Application: Gas
After
Before
(*) This device is approved for use only in Japan.
Thanks to the CSV format data of the
DL8, I can easily check the trend to schedule
maintenance sessions.
The operator may not pay attention
to the anemomether when he is intensely working, but
it's a serious safety issue.
The wind data is now monitored at the
manager's office where the operator can be alerted when high winds occur.
The multiplex transmission system for the PLC is too old to be simply replaced.
The DL8 with wireless network provides an
easy replacement and can be installed in a
short period.
Gas bottles are stored in welding areas dotted throughout
a shipyard making it difficult to know how much gas is remaining in
each area.
I can monitor each bottle level here and I can receive low
level alarm e-mails before they are empty.
900 MHz ISM Band Multi-hop Wireless System
WL40F SeriesWL40F!
Shipbuilding, Automobiles, Other Transportation Equipment,Railroad/Bus, Shipping, and Air Transport
APPLICATIONEXAMPLES
BYINDUSTRIES
12 13
After
pHpH
$ 0
DL8
• Remaining gas volume
• Remaining gas volume
Hospital
Administration room
• pH meter• pH meterDL8
• Water level• Pump ON/OFF• Water level• Pump ON/OFF
60 monitoring points
Administration building
Before
AfterAfter
After
After
Gases for medical purposes
Gases for medical purposes
It’s difficult to conduct additional wiring works in the
hospital for monitoring the newly added gas bottles.
Before
No need of wiring works in
connecting the level sensors wirelessly.
PC
DL8Parent Parent
Child Child
Child
Parent
Inflow pipe
Control panel
Discharge pipe
Manhole pump
Remaining level monitoring ofspecial gas bottles in hospitalRemaining level monitoring ofspecial gas bottles in hospital
Industry: Hospital − Application: GasIndustry: Hospital − Application: Gas
Management of wastewater pH valueon campus
Management of wastewater pH valueon campus
Industry: School − Application: DrainageIndustry: School − Application: Drainage
Environmental monitor for construction siteEnvironmental monitor for construction site
Industry: Construction − Application: Environmental measuresIndustry: Construction − Application: Environmental measures
Monitoring of manhole pumpsMonitoring of manhole pumps
Industry: Gas/Water − Application: Manhole pumpIndustry: Gas/Water − Application: Manhole pump
Volcanic gas monitoringVolcanic gas monitoring
Industry: Service business − Application: Environmental measuresIndustry: Service business − Application: Environmental measures
Power monitoring of supermarketPower monitoring of supermarket
Industry: Retail business − Application: PowerIndustry: Retail business − Application: Power
Before
Switching to 900 MHz wireless band reduces the
network fee to zero.
After
Private telecom lines, or leased lines, need to be updated but there are 60
monitoring points.
The WL40F Series does not need to utilize old telecommunication
lines or network structure.
The network use fees of existing
dedicated lines are a burden.
• Gas detector• Gas detector
After
Before
Administration office
Automatic logging
After
Noise and vibration indicators must be installed
at construction sites, but it’s only for temporary use.
Volcanic gas
Cable car
After
dB
• Air conditioners• Lighting• Refrigerators
• Air conditioners• Lighting• Refrigerators
No worrying about volcanic gas by
connecting wirelessly.
We cannot close the store for a long work period
to add a monitoring point.
DL8
• Noise sensor• Noise sensor
Indicator
Noise indicator
Mountaintop station
The mountain surface may not be safe for cable laying work
between the mountaintop station and the office.
Before
Before
dB
After
After
AfterPC PC
Child Child
Child
Parent Parent
Parent
DL8 DL8
A wireless system is ideal for onsite
display at temporary construction sites.
Only one overnight work period needed
to complete the installation work.
Hospitals, Schools, Construction, Gas/Water Supply, Service Businesses, and Retailers
PC PC
APPLICATIONEXAMPLES
BYINDUSTRIES
900 MHz ISM Band Multi-hop Wireless System
WL40F SeriesWL40F!