Wall Mounting Enclosures 2

Floor Standing Enclosures 34

Stainless Steel Enclosures 66

Power Distribution 90

Data & Telecommunication 102

General Accessories 128

CONTENT

1Content

Page 2: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

2 Wall Mounting Enclosures

FINL

AND

THE

NETH

ERLA

ND

USA

CANA

DA

GERM

ANY

GERM

ANY

GERM

ANY

ENGL

AND

NORW

AY

FRAN

CE

SeriesC

SeriesD,S,O

SeriesW

SeriesM

SeriesH

Wall MountingEnclosure

ABSPolycarbonate

IP 66/67NEMA 4,4x,6,12,13

Wall MountingEnclosure

Polycarbonate IP 66/67NEMA 4,4x,6,12,13

Wall MountingEnclosure

Polycarbonate IP 66/67NEMA 4,4x,6,12,13

Wall MountingEnclosure

Polyester IP 67NEMA 4

Wall MountingEnclosure

Aluminium IP 67NEMA 4

IL,ILF

MAS

Wall MountingEnclosure

Mild Steel IP 66/Ik 09NEMA 4

Wall MountingEnclosure

Mild Steel IP 66NEMA 4,12,13

MAD Wall MountingEnclosure

Mild Steel IP 55NEMA 12

MAP

MAM

HZP,HZPT

Wall MountingEnclosure

Mild Steel IP 66NEMA 4,12,13

Wall Mounting modular system

Mild Steel IP 55NEMA 12

Wall MountingEnclosure

Polyester IP 65

FIType ofenclosure

Series Material Protection level

Enclosure Specification

The designAll Eldon enclosures are designed and developed with due regard to current, relevant international regulations, legislations and standards.Designs are developed to benefit from the many years of experience withinEldon, towards developing user friendly and safe enclosures to meet customer requirements.

The StandardsEldon enclosures meet the current standards and specifications:

All enclosuresEN 60.204 part 1 Electrical equipment of machines. (Earthing)EN 60.529 / IEC 529 Degrees of protection provided by

enclosures.(European IP code)NEMA 250 Enclosures for electrical equipment.

(American TYPE code)

Industrial enclosuresDIN 41.844 part 1 - 3 Measurements for sub-divisions of enclosures.DIN 43.660 Keys for cells or enclosure doors of electrical

switchgear.DIN 43.656 Paint for indoor electrical switchgear.

19 inch and Data enclosuresDIN 41.488 part 1 Measurements for sub-divisions of enclosures,

communication technology, and electronics.DIN 41.494 Part 1 Construction for electronic equipment, front plates

and racks. Part 3 Component stacking, dimensions.

ANSI/EIA-310-C-77 Racks panels and accosted equipment.

Other local regulations and specifications concerning the siting of electricalswitchgear must be observed by the user of the enclosures!

Page 3: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

3

Wall Mounting Enclosures

Wall Mounting Enclosures

Page4 IL(F), Installation Enclosures

15 MAS, Wall Mounting Enclosures, single door17 MAD, Wall Mounting Enclosures, double door18 MAP, Wall Mounting Enclosures, panel19 MAM, Wall Mounting Modular System29 HZP, HZPT, Wall Mounting Polyester enclosures

IL, ILF

MAS, MAD

MAP

MAM

HZP, HZPT

Page 4

Page 15

Page 18

Page 19

Page 29

Page 4: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

4 Wall Mounting Enclosures

Installation enclosures

IP 66/67, NEMA 4, 4X, 6, 12, 13

DPCP, Polyester enclosure

With grey coverH W D Cat.no.53 55 36 DPCP 050504 GE

63 36 DPCP 050704 GE80 82 56 DPCP 080806 GE

86 DPCP 080809 GE120 56 DPCP 081206 GE

86 DPCP 081209 GE160 56 DPCP 081606 GE

86 DPCP 081609 GE120 122 56 DPCP 121206 GE

86 DPCP 121209 GE160 91 DPCP 121609 GE200 86 DPCP 122009 GE

150 200 76 DPCP 152008 GE160 240 91 DPCP 162409 GE

121 DPCP 162412 GE230 300 86 DPCP 233009 GE

111 DPCP 233011 GE

Temperature resistance: -50°C to + 125°C (transparent cover)Characteristics: UV resistent. For external/internal use.Flammability: UL94 V-2Finish: RAL 7035Pack. quantity: 1 piece

With transparent coverIK 08For external/internal use

H W D Cat.no.53 55 36 DPCP 050504 TE

63 36 DPCP 050704 TE80 82 56 DPCP 080806 TE

86 DPCP 080809 TE120 56 DPCP 081206 TE

86 DPCP 081209 TE160 56 DPCP 081606 TE

86 DPCP 081609 TE120 122 56 DPCP 121206 TE

86 DPCP 121209 TE160 91 DPCP 121609 TE200 86 DPCP 122009 TE

150 200 76 DPCP 152008 TE160 240 91 DPCP 162409 TE

121 DPCP 162412 TE230 300 86 DPCP 233009 TE

111 DPCP 233011 TE

IP 66/67, NEMA 4, 4X, 6, 12, 13

DABP, ABS enclosure

Temperature resistance: -40°C to + 60°CCharacteristics: Not UV resistant. For internal use. IK 06/IK 07Flammability: UL94 HBFinish: RAL 7035Pack. quantity: 1 piece

With transparent coverH W D Cat.no.53 55 36 DABP 050504 TE

63 36 DABP 050704 TE80 82 56 DABP 080806 TE

86 DABP 080809 TE120 56 DABP 081206 TE

86 DABP 081209 TE160 56 DABP 081606 TE

86 DABP 081609 TE120 122 56 DABP 121206 TE

86 DABP 121209 TE160 91 DABP 121609 TE200 86 DABP 122009 TE

150 200 76 DABP 152008 TE160 240 91 DABP 162409 TE

121 DABP 162412 TE230 300 86 DABP 233009 TE

111 DABP 233011 TE

With grey coverH W D Cat.no.53 55 36 DABP 050504 GE

63 36 DABP 050704 GE80 82 56 DABP 080806 GE

86 DABP 080809 GE120 56 DABP 081206 GE

86 DABP 081209 GE160 56 DABP 081606 GE

86 DABP 081609 GE120 122 56 DABP 121206 GE

86 DABP 121209 GE160 91 DABP 121609 GE200 86 DABP 122009 GE

150 200 76 DABP 152008 GE160 240 91 DABP 162409 GE

121 DABP 162412 GE230 300 86 DABP 233009 GE

111 DABP 233011 GE

Page 5: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

5Wall Mounting Enclosures

Accessories

Hinges, DSHI

Material: PolyamidePack quantity: 1 pair

H D Weight Cat.no.28 28 27 DSHI 1 E

Blind plug, DCP 1E

Pack quantity: 1 piece

Cat.no.DCP 1E

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Mounting plate, DMP

Material: 1.5 mm galvanised steel.Pack quantity: 1 piece

H W Cat.no.80 82 DMP 0808 E

120 DMP 0812 E160 DMP 0816 E

120 122 DMP 1212 E160 DMP 1216 E200 DMP 1220 E

150 200 DMP 1520 E160 240 DMP 1624 E230 300 DMP 2330 EDIN rail, DR

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Material: steel.Pack quantity: 1 piece

For enclosure dimension:Dim. mm Cat.no.15 x 26 DR 15016-4 E15 x 48 DR 15038-4 E15 x 68 DR 15058-4 E15 x 106 DR 15096-4 E15 x 146 DR 15136-4 E35 x 68 DR 35058-4 E35 x 106 DR 35096-4 E35 x 146 DR 35136-4 E35 x 170 DR 35160-4 E35 x 186 DR 35176-4 E35 x 225 DR 35215-4 E35 x 285 DR 35275-4 E35 x 340 DR 35330-4 E

Page 6: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

6 Wall Mounting Enclosures

Installation enclosures

IP 67/NEMA 4

HALP, Aluminium enclosures

Protection: IP 67 (IEC 529) and NEMA 4X.Finish: RAL 7001Approvals: UL, CSA, SAA, Eex “i”, Eex “e”Pack. quantity: 1 piece

Aluminium AL Si12 (LM6).H W D Cat.no.45 50 30 HALP 050503 GE64 58 36 HALP 060604 GE

98 36 HALP 061004 GE150 36 HALP 061504 GE

80 75 57 HALP 080806 GE125 57 HALP 081306 GE175 57 HALP 081806 GE250 57 HALP 082506 GE

120 122 80 HALP 121208 GE90 HALP 121209 GE

220 80 HALP 122208 GE90 HALP 122209 GE

360 80 HALP 123608 GE160 160 90 HALP 161609 GE

260 90 HALP 162609 GE360 90 HALP 163609 GE560 90 HALP 165609 GE

230 200 110 HALP 232011 GE330 110 HALP 233311 GE

180 HALP 233318 GE400 110 HALP 234011 GE600 110 HALP 236011 GE

240 420 210 HALP 244221 GE

Mounting plate, HMP Material: 1,5 mm galvanised steel platePack. quantity: 1 piece

H W Cat.no.45 50 HMP 0505 E64 58 HMP 0606 E

98 HMP 0610 E150 HMP 0615 E

80 75 HMP 0808 E125 HMP 0813 E175 HMP 0818 E250 HMP 0825 E

120 122 HMP 1212 E221 HMP 1222 E360 HMP 1236 E

160 160 HMP 1616 E260 HMP 1626 E360 HMP 1636 E560 HMP 1656 E

230 200 HMP 2320 E330 HMP 2333 E400 HMP 2340 E600 HMP 2360 E

240 420 HMP 2442 E

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Page 7: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

7Wall Mounting Enclosures

Installation enclosures

IP 67/NEMA 4X

MGRP, Polyester enclosures

Temperature resistance: Fitted with neoprene gasket -40°C to+80°C. With special silicone gasket -70°C to +130°C.Mechanical impact: 7 Nm, s/EN 50014Finish: RAL 7001Pack. quantity: 1 piece

H W D Cat.no.75 80 55 MGRP 080806 GE

75 MGRP 080808 GE110 55 MGRP 081106 GE

75 MGRP 081108 GE160 55 MGRP 081606 GE

75 MGRP 081608 GE190 55 MGRP 081906 GE

75 MGRP 081908 GE120 122 90 MGRP 121209 GE

220 90 MGRP 122209 GE160 160 90 MGRP 161609 GE

260 90 MGRP 162609 GE360 90 MGRP 163609 GE560 90 MGRP 165609 GE

250 255 120 MGRP 252612 GE400 120 MGRP 254012 GE600 120 MGRP 256012 GE

405 400 120 MGRP 414012 GE

Mounting plate, GMP

H W Cat.no.75 80 GMP 0808 E

110 GMP 0811 E160 GMP 0816 E190 GMP 0819 E230 GMP 0823 E

120 122 GMP 1212 E220 GMP 1222 E

160 160 GMP 1616 E260 GMP 1626 E360 GMP 1636 E560 GMP 1656 E

250 255 GMP 2526 E400 GMP 2540 E600 GMP 2560 E

400 400 GMP 4140 E

Material: 1,5 mm galvanised steel plate

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Page 8: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

8 Wall Mounting Enclosures

Installation enclosures

IP 66/67, NEMA 4, 4X, 12, 13

SABP, ABS enclosures

Flammability: UL94 HBCharacteristics: Not UV resistant. For internal use.Temperature resistance: - 40°C to + 60°CFinish: RAL 7035Pack. quantity: 1 piece

With transparent coverPlain walls in the base

H W D Cat.no.75 125 75 SABP 081308 TE

100 SABP 081310 TE125 SABP 081313 TE

125 125 75 SABP 131308 TE175 75 SABP 131808 TE125 100 SABP 131310 TE

125 SABP 131313 TE175 100 SABP 131810 TE

125 SABP 131813 TE150 SABP 131815 TE

175 175 75 SABP 181808 TE250 75 SABP 182508 TE

100 SABP 182510 TE175 100 SABP 181810 TE

125 SABP 181813 TE150 SABP 181815 TE

250 150 SABP 182515 TE

With grey coverPlain walls in the base

H W D Cat.no.75 125 75 SABP 081308 GE

100 SABP 081310 GE125 SABP 081313 GE

125 125 75 SABP 131308 GE100 SABP 131310 GE125 SABP 131313 GE

175 75 SABP 131808 GE100 SABP 131810 GE125 SABP 131813 GE150 SABP 131815 GE

175 175 75 SABP 181808 GE100 SABP 181810 GE125 SABP 181813 GE150 SABP 181815 GE

250 75 SABP 182508 GE100 SABP 182510 GE150 SABP 182515 GE

SPCK, Polycarbonate enclosures

With grey cover and knock outsH W D Cat.no.75 125 75 SPCK 081308 GE

100 SPCK 081310 GE125 SPCK 081313 GE

125 125 75 SPCK 131308 GE100 SPCK 131310 GE125 SPCK 131313 GE

175 75 SPCK 131808 GE100 SPCK 131810 GE125 SPCK 131813 GE150 SPCK 131815 GE

175 175 75 SPCK 181808 GE100 SPCK 181810 GE125 SPCK 181813 GE150 SPCK 181815 GE

250 75 SPCK 182508 GE100 SPCK 182510 GE150 SPCK 182515 GE

With transparent cover and knock outsH W D Cat.no.75 125 75 SPCK 081308 TE

100 SPCK 081310 TE125 SPCK 081313 TE

125 125 75 SPCK 131308 TE100 SPCK 131310 TE125 SPCK 131313 TE

175 75 SPCK 131808 TE100 SPCK 131810 TE125 SPCK 131813 TE150 SPCK 131815 TE

175 175 75 SPCK 181808 TE100 SPCK 181810 TE125 SPCK 181813 TE150 SPCK 181815 TE

250 75 SPCK 182508 TE100 SPCK 182510 TE150 SPCK 182515 TE

Flammability: UL94 V-0...V-2Characteristics: UV ResistantTemperature resistance: - 50°C to + 125°C (transparent cover)Finish: RAL 7035Pack. quantity: 1 piece

IP 66/67, NEMA 4, 4X, 12, 13

Page 9: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

9Wall Mounting Enclosures

Installation enclosures

Blind plugs, SCP

Replaces original screw on hinge side when hinges are fittedPack quantity: 10 pieces

Cat.no.SCP 08 ESCP 10 E

Mounting plates, SMP

Material: 1,5 mm galvanised steelPack. quantity: 1 pieces

H W Cat.no.75 125 SMP 0813 E

125 125 SMP 1313 E175 SMP 1318 E

175 175 SMP 1818 E250 SMP 1825 E

Wall mounting brackets, SFL

Pack quantity: 4 pieces

H W Weight Cat.no.15 30 0,11 SFL 1 E

DIN rail, DR

Material: steel.Pack quantity: 1 piece

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

For enclosure dimension:Dim. mm Cat.no.

75 DR 35040-4 E125 DR 35090-4 E175 DR 35140-4 E250 DR 35215-4 E

IP 66/67, NEMA 4, 4X, 12, 13

SPCP, Polycarbonate enclosures

Flammability: UL94 V-0...V-2Characteristics: UV Resistant. With plain walls in the base.Temperature resistance: - 50°C to + 125°C (transparent cover)Finish: RAL 7035Pack. quantity: 1 piece

With grey coverH W D Cat.no.75 125 75 SPCP 081308 GE

100 SPCP 081310 GE125 SPCP 081313 GE

125 125 75 SPCP 131308 GE100 SPCP 131310 GE125 SPCP 131313 GE

175 75 SPCP 131808 GE100 SPCP 131810 GE125 SPCP 131813 GE150 SPCP 131815 GE

175 175 75 SPCP 181808 GE100 SPCP 181810 GE125 SPCP 181813 GE150 SPCP 181815 GE

250 75 SPCP 182508 GE100 SPCP 182510 GE150 SPCP 182515 GE

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

With transparent coverH W D Cat.no.75 125 75 SPCP 081308 TE

100 SPCP 081310 TE125 SPCP 081313 TE

125 125 75 SPCP 131308 TE100 SPCP 131310 TE125 SPCP 131313 TE

175 75 SPCP 131808 TE100 SPCP 131810 TE125 SPCP 131813 TE150 SPCP 131815 TE

175 175 75 SPCP 181808 TE100 SPCP 181810 TE125 SPCP 181813 TE150 SPCP 181815 TE

250 75 SPCP 182508 TE100 SPCP 182510 TE150 SPCP 182515 TE

Page 10: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

10 Wall Mounting Enclosures

Installation enclosures

IP 66/67, NEMA 4, 4X, 6. 12, 13

OABP, ABS enclosures

ABS with transparent coverH W D Cat.no.

200 200 130 OABP 202013 TE300 130 OABP 203013 TE400 130 OABP 204013 TE

300 300 130 OABP 303013 TE400 130 OABP 304013 TE600 130 OABP 306013 TE

400 600 130 OABP 406013 TE

With grey coverWithout extension frame

H W D Cat.no.200 200 130 OABP 202013 GE

300 130 OABP 203013 GE400 130 OABP 204013 GE

300 300 130 OABP 303013 GE400 130 OABP 304013 GE600 130 OABP 306013 GE

400 600 130 OABP 406013 GE

IP 66/67, NEMA 4, 4X, 6, 12, 13

OPCP, Polycarbonate enclosures

With grey coverwithout extension frame

H W D Cat.no.200 200 130 OPCP 202013 GE

300 130 OPCP 201313 GE400 130 OPCP 204013 GE

300 300 130 OPCP 303013 GE400 130 OPCP 304013 GE600 130 OPCP 306013 GE

400 600 130 OPCP 406013 GE

With transparent coverwithout extension frame

H W D Cat.no.200 200 130 OPCP 202013 TE

300 130 OPCP 201313 TE400 130 OPCP 204013 TE

300 300 130 OPCP 303013 TE400 130 OPCP 304013 TE600 130 OPCP 306013 TE

400 600 130 OPCP 406013 TE

Temperature resistance: -40°C to +60°CFlammability: UL94 HBCharacteristics: Not UV resistant. For internal use. IK 06/07Finish: RAL 7035Pack. quantity: 1 piece

Temperature resistance: -50°C to +125°CFlammability: UL94 V-0..V-2Characteristics: UV resistantFinish: RAL 7035

Page 11: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

11Wall Mounting Enclosures

Accessories

Adapter support, OTS

Cat.no.OTS 1 E

Mounting plate, OMP

Material: Galvanised steel

H W Cat.no.200 200 OMP 2020 E

300 OMP 2030 E400 OMP 2040 E

300 300 OMP 3030 E400 OMP 3040 E600 OMP 3060 E

400 600 OMP 4060 E

Wing screw, OLW

Replaces supplied screws.

Cat.no.OLW 55 E

Wall mounting brackets, OFL

Material: polyamide.Pack quantity: 4 brackets with mounting material.

Description Cat.no.Set of 4 pieces OFL E

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Blind plugs, OCP

Cat.no.OCP 1 E

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Extension frameH W D Cat.no.

200 200 55 OPCP 202013 EE300 55 OPCP 201313 EE400 55 OPCP 204013 EE

300 300 55 OPCP 303013 EE400 55 OPCP 304013 EE600 55 OPCP 306013 EE

400 600 55 OPCP 406013 EE

For fixing cover on the rear of the enclosure.

Replaces original screw on hinge side when hinges are fitted.

DIN rail, DR

Material: steel.Pack quantity: 1 piece

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

For enclosure dimension:Dim. mm Cat.no.

200 DR 35150-5E300 DR 35250-5E400 DR 35350-5EZ

Page 12: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

12 Wall Mounting Enclosures

Installation enclosures

Flange gaskets, F-GE

Self-adhesive. Material: EDPM.

Size Cat.no.1 F 1 GE2 F 2 GE

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Cover flanges, FE

Size Material Cat.no.1 Bayblend F 1151 E2 Polycarbonat F 2251 E

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Depth adjustment kit, OEL

Cat.no.OEL 1 E

Flange support, PMR

Material: Polycarbonate (PC)Pack quantity: 1 piece

Size Cat.no.2 PMR 1857 E

Hinges, OHI

Set of 2 Polycarbonat hinges.

Cat.no.OHI 1 E

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Knock-out gland plates, F

For series CPCF. Including PUR-gasketMaterial: Polycarbonate or bayblend

Size Cat.no.2 F 2253 E2 F 2254 E

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

IP 66/67, NEMA 4, 4X, 6, 12, 13

CPCF, Polyester Enclosures

Material: Enclosure in glass filled Polycarbonate. grey and transparentcovers in Polycarbonate.Temperature resistance: -50°C to +125°CFlammability: Glass filled Polycarbonate: UL94 V…0Polycarbonate: UL94 V-2Finish: RAL 7035Features: Pre-pressed flange knockouts on all base sides. Possible tocombine enclosures

With transparent cover, IP 67, IK 08H D W Cat.no.

200 200 130 CPCF 202013 TE300 130 CPCF 203013 TE400 130 CPCF 204013 TE

300 300 130 CPCF 303013 TE400 130 CPCF 304013 TE600 130 CPCF 306013 TE

400 600 130 CPCF 406013 TE

With grey cover, IP 67, IK 08H W D Cat.no.

200 200 130 CPCF 202013 GE300 130 CPCF 203013 GE400 130 CPCF 204013 GE

300 300 130 CPCF 303013 GE400 130 CPCF 304013 GE600 130 CPCF 306013 GE

400 600 130 CPCF 406013 GE

Page 13: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

13Wall Mounting Enclosures

Installation enclosures

IP 66/67, NEMA 4, 4X, 6, 12, 13

WPCP, Polycarbonate enclosures

Temperature resistance: -50°C to +125°CFlamability: UL94 V-0 … V-2Characteristics: With hinges and quick release latches.Finish: RAL 7035Pack. quantity: 1 piece

With transparent cover(For depth 185 included extension frame OPCP … E)

H W D Cat.no.200 200 130 WPCP 202013 TE

300 130 WPCP 203013 TE400 130 WPCP 204013 TE

300 300 130 WPCP 303013 TE400 130 WPCP 304013 TE600 130 WPCP 306013 TE

400 600 130 WPCP 406013 TE200 200 185 WPCP 202018 TE

300 185 WPCP 203018 TE400 185 WPCP 204018 TE

300 300 185 WPCP 303018 TE400 185 WPCP 304018 TE600 185 WPCP 306018 TE

400 600 185 WPCP 406018 TE

With grey cover(For depth 185 included extension frame OPCP … E)

H W D Cat.no.200 200 130 WPCP 202013 GE

300 130 WPCP 203013 GE400 130 WPCP 204013 GE

300 300 130 WPCP 303013 GE400 130 WPCP 304013 GE600 130 WPCP 306013 GE

400 600 130 WPCP 406013 GE200 200 185 WPCP 202018 GE

300 185 WPCP 203018 GE400 185 WPCP 204018 GE

300 300 185 WPCP 303018 GE400 185 WPCP 304018 GE600 185 WPCP 306018 GE

400 600 185 WPCP 406018 GE

Page 14: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

14 Wall Mounting Enclosures

Installation enclosures

IL, Steel plate enclosures ILF, Steel plate enclosures

Mounting plates, IMP

Material: 2.0 mm galvanised steel

H W Cat.no.150 150 IMP 1515

290 IMP 1530200 190 IMP 2020

290 IMP 2030390 IMP 2040490 IMP 2050590 IMP 2060790 IMP 2080

300 290 IMP 3030390 IMP 3040490 IMP 3050590 IMP 3060

400 390 IMP 4040590 IMP 4060790 IMP 4080

Hinges, ILH Material: Stainless steelPack quantity: 2 pieces with mounting material

Cat.no.ILH 02

Wall mounting brackets, ILB

Material: Galvanised steel. Pack quantity: 4 brackets

Height Cat.no.40 mm ILB 110 mm ILB 2

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Without gland plate openingsH W D Cat.no.

150 150 80 IL 151508300 80 IL 153008

200 200 80 IL 202008300 80 IL 203008400 80 IL 204008500 80 IL 205008600 80 IL 206008800 80 IL 208008

300 300 80 IL 303008400 80 IL 304008500 80 IL 305008600 80 IL 306008

400 400 80 IL 404008600 80 IL 406008800 80 IL 408008

Material: 1.5 mm steel plate.Finish: Painted RAL 7032Pack. quantity: 1 piece

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Gland plates, ILG ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Painted RAL 7032. Pack quantity: 1 piece with fixing material.

Cat.no.ILG 1

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

IP 66/IK09/NEMA 4 IP 66/IK 09/NEMA 4

With gland plate openingsH W D Cat.no.

150 300 120 ILF 153012200 300 120 ILF 203012

400 120 ILF 204012500 120 ILF 205012600 120 ILF 206012800 120 ILF 208012

300 300 120 ILF 303012400 120 ILF 304012500 120 ILF 305012600 120 ILF 306012

400 400 120 ILF 404012600 120 ILF 406012800 120 ILF 408012

Material: 1.5mm steel plateFinish: RAL7032Features: Gland openings on both sides. Supplied with gland plate and gasketPack. quantity: 1 piece

Page 15: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

15Wall Mounting Enclosures

MAS

Mounting plate: The plate is marked at 10mm intervals for easy hori-zontal positioning of equipment on the mounting plate. On the top andbottom are holes to facilitate cable fixing.Fixed onto M8 press welded studs to the rear of the enclosure. All sidesfrom 1000 mm and above are strengthened by folded edges. By usingthe AMG accessory the mounting plate position can be adjusted to anydepth.Gland plate opening: Situated at the far rear of the enclosure toaccommodate easy cabling onto the mounting plate.Finish: Body, door and gland plate: grey RAL 7032 structure polyesterpowder paint.Protection: Corresponds with IP 66 and NEMA 4, 12 and 13.Delivery includes: Two door mounting profiles (size MAS 0505021and larger). Mounting plate with fitting accessories.Gland plate(s) with gasket(s) and fitting. Nylon washers to seal the fixingholes.

IP 66/NEMA 4, 12, 13

MAS, Wall Mounting Enclosures, single door

Material: Body: Steel plate 1.2mm/1.5 mm (AS 06062 and above)Door: Steel plate 1.2 mm1.5 mm (MAS 0605021 and above)2.0 mm (MAS 1008030 and above)Mounting plate: 2.5 mm galvanised steel.

With mounting plateGland Gland Weight plate plate with MP

H W D h w d size opening (Kg) Cat.no.200 200 155 170 150 137 110x56 1 2.3 MAS 0202015250 200 155 220 150 137 110x56 1 2.7 MAS 0252015

250 155 220 200 137 110x56 1 3.2 MAS 0252515300 250 155 270 200 137 110x56 1 3.8 MAS 0302515

210 270 200 192 110x56 1 3.6 MAS 0302521300 155 270 250 137 210x56 1 4.3 MAS 0303015

210 270 250 192 210x96 1 5.5 MAS 0303021350 250 155 320 200 137 110x56 1 4.2 MAS 0352515400 300 155 370 250 137 210x56 1 5.2 MAS 0403015

210 370 250 192 210x96 1 7 MAS 0403021400 210 370 350 192 310x96 1 8.6 MAS 0404021500 210 370 450 192 410x96 1 10.5 MAS 0405021600 210 370 550 192 510x96 1 12.2 MAS 0406021

500 300 210 470 250 192 210x96 1 8.6 MAS 0503021400 155 470 350 137 310x96 1 8.5 MAS 0504015

210 470 350 192 310x96 1 10.4 MAS 0504021260 470 350 242 310x96 1 11.2 MAS 0504026300 470 350 282 310x96 1 12.1 MAS 0504030

500 210 470 450 192 410x96 1 12.6 MAS 0505021300 470 450 282 410x96 1 14.5 MAS 0505030

600 400 155 570 350 137 310x56 1 8.5 MAS 0604015210 570 350 192 310x96 1 12.2 MAS 0604021260 570 350 242 310x96 1 13.6 MAS 0604026300 570 350 282 310x96 1 14.5 MAS 0604030

500 155 570 450 137 410x56 1 10.3 MAS 0605015210 570 450 192 410x96 1 15.4 MAS 0605021260 570 450 242 410x96 1 16.6 MAS 0605026300 570 450 282 410x96 1 17.5 MAS 0605030

600 210 570 550 192 510x96 1 21 MAS 0606021300 570 550 282 510x96 1 24 MAS 0606030400 570 550 382 510x96 1 27 MAS 0606040

800 300 570 750 282 310x96 2 31 MAS 0608030700 500 210 670 450 192 410x96 1 21 MAS 0705021

260 670 450 242 410x96 1 23.2 MAS 0705026

Body: Folded and seam welded. Four wall fixing holes are fitted withthreaded rivets, which makes wall mounting from the outside possible.The rivets protrude 1.5 mm which prevents the back from damagewhile laying on it’s back and to allow airflow around the rear.Door: Surface mounted with 130° opening.Concealed removable hinge with captive pin. Hinges can be mountedto allow left or right hand opening. From size MAS 0505021 and largerthere are two removable mounting profiles in the door. Sealing is ensu-red by an extruded one piece polyurethane gasket.Lock: Customised lock with double grip for easy opening of the door,DIN-lock with 3 mm pin and 90° movement. 1000 and 1200 mm highenclosures have espagnolet, three point locking. Other inserts are avai-lable.

Page 16: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

16 Wall Mounting Enclosures

MAS

800 400 300 770 350 282 310x96 1 24 MAS 0804030600 210 770 550 192 510x96 1 28 MAS 0806021

260 770 550 242 510x96 1 29.8 MAS 0806026300 770 550 282 510x96 1 31 MAS 0806030400 770 550 382 510x96 1 34 MAS 0806040

800 210 770 750 192 310x96 2 35 MAS 0808021300 770 750 282 310x96 2 39 MAS 0808030400 770 750 382 310x96 2 43 MAS 0808040

1000 600 260 970 550 242 510x96 1 38 MAS 1006026300 970 550 282 510x96 1 39 MAS 1006030

800 260 970 750 242 310x96 2 44 MAS 1008026300 970 750 282 310x96 2 47 MAS 1008030400 970 750 382 310x96 2 51 MAS 1008040

1200 600 300 1170 550 282 510x96 1 51 MAS 1206030800 300 1170 750 282 310x96 2 66 MAS 1208030

400 1170 750 382 310x96 2 66 MAS 1208040

With mounting plateGland Gland Weight plate plate with MP

H W D h w d size opening (Kg) Cat.no.

Without mounting plateGland Gland Weight plate plate with MP

H W D h w d size opening (Kg) Cat.no.200 200 155 170 150 137 110x56 1 2.3 MAS 0202015 PE250 200 155 220 150 137 110x56 1 2.7 MAS 0252015 PE

250 155 220 200 137 110x56 1 3.2 MAS 0252515 PE300 250 155 270 200 137 110x56 1 3.8 MAS 0302515 PE

210 270 200 192 110x56 1 3.6 MAS 0302521 PE300 155 270 250 137 210x56 1 4.3 MAS 0303015 PE

210 270 250 192 210x96 1 5.5 MAS 0303021 PE350 250 155 320 200 137 110x56 1 4.2 MAS 0352515 PE400 300 155 370 250 137 210x56 1 5.2 MAS 0403015 PE

210 370 250 192 210x96 1 7 MAS 0403021 PE400 210 370 350 192 310x96 1 8.6 MAS 0404021 PE500 210 370 450 192 410x96 1 10.5 MAS 0405021 PE600 210 370 550 192 510x96 1 12.2 MAS 0406021 PE

500 300 210 470 250 192 210x96 1 8.6 MAS 0503021 PE400 155 470 350 137 310x96 1 8.5 MAS 0504015 PE

210 470 350 192 310x96 1 10.4 MAS 0504021 PE260 470 350 242 310x96 1 11.2 MAS 0504026 PE300 470 350 282 310x96 1 12.1 MAS 0504030 PE

500 210 470 450 192 410x96 1 12.6 MAS 0505021 PE300 470 450 282 410x96 1 14.5 MAS 0505030 PE

600 400 155 570 350 137 310x56 1 8.5 MAS 0604015 PE210 570 350 192 310x96 1 12.2 MAS 0604021 PE260 570 350 242 310x96 1 13.6 MAS 0604026 PE300 570 350 282 310x96 1 14.5 MAS 0604030 PE

500 155 570 450 137 410x56 1 10.3 MAS 0605015 PE210 570 450 192 410x96 1 15.4 MAS 0605021 PE260 570 450 242 410x96 1 16.6 MAS 0605026 PE300 570 450 282 410x96 1 17.5 MAS 0605030 PE

600 210 570 550 192 510x96 1 21 MAS 0606021 PE300 570 550 282 510x96 1 24 MAS 0606030 PE400 570 550 382 510x96 1 27 MAS 0606040 PE

800 300 570 750 282 310x96 2 31 MAS 0608030 PE700 500 210 670 450 192 410x96 1 21 MAS 0705021 PE

260 670 450 242 410x96 1 23.2 MAS 0705026 PE800 400 300 770 350 282 310x96 1 24 MAS 0804030 PE

600 210 770 550 192 510x96 1 28 MAS 0806021 PE260 770 550 242 510x96 1 29.8 MAS 0806026 PE300 770 550 282 510x96 1 31 MAS 0806030 PE400 770 550 382 510x96 1 34 MAS 0806040 PE

800 210 770 750 192 310x96 2 35 MAS 0808021 PE300 770 750 282 310x96 2 39 MAS 0808030 PE400 770 750 382 310x96 2 43 MAS 0808040 PE

1000 600 260 970 550 242 510x96 1 38 MAS 1006026 PE300 970 550 282 510x96 1 39 MAS 1006030 PE

800 260 970 750 242 310x96 2 44 MAS 1008026 PE300 970 750 282 310x96 2 47 MAS 1008030 PE400 970 750 382 310x96 2 51 MAS 1008040 PE

1200 600 300 1170 550 282 510x96 1 51 MAS 1206030 PE800 300 1170 750 282 310x96 2 66 MAS 1208030 PE

400 1170 750 382 310x96 2 66 MAS 1208040 PE

Page 17: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

17Wall Mounting Enclosures

MAD

Lock: Customised lock with double grip for easy opening of the door,DIN-lock with 3 mm pin and 90° movement. Espagnolette three pointlocking. Other inserts are availableMounting plate: The plate is marked at 10mm intervals for easy hori-zontal positioning of equipment on the mounting plate. On the top andbottom are holes to facilitate cable fixing.Fixed onto M8 press welded studs to the rear of the enclosure. All sidesfrom 1000 mm and above are strengthened by folded edges. By usingthe AMG accessory the mounting plate position can be adjusted to anydepth.Gland plate opening: Situated at the far rear of the enclosure toaccommodate easy cabling onto the mounting plate.Finish: Body, door and gland plate: grey RAL 7032 structure polyesterpowder paint.Protection: Corresponds with IP 55 and NEMA 12.Delivery includes: Two door mounting profiles on the right hand door.Mounting plate with fitting accessories. Gland plates with gaskets andfitting accessories. Earthing facilities for mounting plate and glandplates. Nylon washers to seal the fixing holes.

Without mounting plateGland Gland Weight plate plate with MP

H W D h w d size opening (Kg) Cat.no.600 800 300 570 750 282 310x96 2 31 MAD 0608030 PE800 1200 300 770 1150 282 510x96 2 48 MAD 0801230 PE

1000 1000 300 970 950 282 410x96 2 63 MAD 1001030 PE1200 1000 300 1170 950 282 410x96 2 74 MAD 1201030 PE

1200 300 1170 1150 282 510x96 2 86 MAD 1201230 PE400 1170 1150 382 510x96 2 92 MAD 1201240 PE

1400 1000 300 1370 950 282 410x96 2 84 MAD 1401030 PE

IP 55/NEMA 12

MAD, Wall Mounting Enclosures, double door

Material: Steel plate, 1.5 mm. Doors: Steel plate, 1.5 mm(MAD 0801230 and smaller), 2.0 mm (MAD 1001030 and larger)Mounting plate: 2.5 mm galvanised steel.Body: Folded and seam welded. Four wall fixing holes are fitted withthreaded rivets, which makes wall mounting from the outside possible.The rivets Protrude 1.5 mm which prevents the back from damagewhile laying on it’s back and to allow airflow around the rear.Door: Surface mounted with 130° opening.Concealed removable hinges with captive pin. Removable mountingprofiles in the right hand door. Sealing is ensured by an extruded onepiece polyurethane gasket.

With mounting plateGland Gland Weight plate plate with MP

H W D h w d size opening (Kg) Cat.no.600 800 300 570 750 282 310x96 2 31 MAD 0608030800 1200 300 770 1150 282 510x96 2 48 MAD 0801230

1000 1000 300 970 950 282 410x96 2 63 MAD 10010301200 1000 300 1170 950 282 410x96 2 74 MAD 1201030

1200 300 1170 1150 282 510x96 2 86 MAD 1201230400 1170 1150 382 510x96 2 92 MAD 1201240

1400 1000 300 1370 950 282 410x96 2 84 MAD 1401030

Page 18: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

18 Wall Mounting Enclosures

MAP

Gland plate opening: In top and bottom. Gland plates and gasketsnot included. Situated at the far rear of the enclosure to accommodateeasy cabling onto the mounting plate. The gland plates used are thosedelivered with the MAS or MAD enclosure.Finish: Body, panel and gland plate: grey RAL 7032 structure polyes-ter powder paint.Protection: As stand alone: Corresponds with IP 66 and NEMA 4, 12and 13. Combined with MAS or MAD: Corresponds with I P55 and NEMA 12.Delivery includes: Mounting plate with fitting accessories and earthingfacilities. Nylon washers to seal the fixing holes.

Without mounting plateGland Gland Weight plate plate with MP

H W D h w d size opening (Kg) Cat.no.300 270 550 282 510x96 2 15 MAP 0306030 PE300 270 750 282 310x96 4 18 MAP 0308030 PE300 270 950 282 410x96 4 21 MAP 0310030 PE300 270 1150 282 510x96 4 24 MAP 0312030 PE

IP 66/NEMA 4, 12, 13

MAP, Wall mounting enclosure, panel

Material: Body: Steel plate, 1.5 mmMounting plate: 2.0 for MAP 0306030 and 2.5 mm galvanised steelMAP 0306030 and above.Body: Folded and seam welded. Four wall fixing holes are fitted withthreaded rivets, which makes wall mounting from the outside possible.The rivets Protrude 1.5 mm which prevents the back from damagewhile laying on it’s back and to allow airflow around the rear.Front panel: Surface mounted with 90° opening.Concealed removable hinge with captive pin can be mounted to allowtop or bottom opening. Held open by mechanical panel stays. Sealingis ensured by an extruded one piece polyurethane gasket.Lock: Customised lock with double grip for easy opening of the door,DIN-lock with 3 mm pin and 90° movement. Other inserts are availableMounting plate: The plate is marked at 10 mm intervals for easy hori-zontal positioning of equipment on the mounting plate. On the top andbottom are holes to facilitate cable fixing.Fixed onto M8 press welded studs to the rear of the enclosure. All sidesfrom 1000 mm and above are strengthened by folded edges. By usingthe AMG accessory the mounting plate position can be adjusted to anydepth.

With mounting plateGland Gland Weight plate plate with MP

H W D h w d size opening (Kg) Cat.no.300 600 300 270 550 282 510x96 2 15 MAP 0306030

800 300 270 750 282 310x96 4 18 MAP 03080301000 300 270 950 282 410x96 4 21 MAP 03100301200 300 270 1150 282 510x96 4 24 MAP 0312030

Page 19: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

19Wall Mounting Enclosures

MAM

IP 55/NEMA 12

MAM, Wall mounting modular System

Description: MAM enclosures exist in three different heights 800, 1000& 1200 mm, with a width of 600 mm and a depth of 210 mm. The frontpanels, blank or slotted are in multiples of 150 mm per unit high. Eachrow can accept a maximum of 27 modules of 18 mm wide.The assembly contains: a full standard MAS enclosure body withoutmounting plate, a glazed door ADT, a modular vertical support ACMand a combination of blank MBP & slotted MCP panels according tothe enclosure height and the configuration.For all detailed information about these parts, see the appropriatepages in the catalogue.Protection: Corresponds with IP 55

Pre-defined MAM configurations and catalogue references(The last digit of the catalogue reference indicates the number of slotted units)

No of No of Total No slotted blank of 18mm

H W D rows rows wide Modules Cat.no.800 600 210 2 3 54 MAM 080622

210 3 2 81 MAM 080623210 4 1 108 MAM 080624210 5 0 135 MAM 080625

1000 600 210 3 3 81 MAM 100623210 4 2 108 MAM 100624210 5 1 135 MAM 100625210 6 0 162 MAM 100626

1200 600 210 4 3 108 MAM 120624210 5 2 135 MAM 120625210 6 1 162 MAM 120626210 7 0 189 MAM 120627

Modular slotted panel, MCP

Front panel for modules. Provided with one DIN rail (PP 1535) per row Material: 1.5 mm steel plate, powder structure paint, RAL 7032.Pack quantity: 1 piece with mounting material.

N° of N° of W h rows modules Cat.no.400 150 1 14/1 MCP 1504600 150 1 24/1 MCP 1506

200 1 24/1 MCP 2006300 2 48/2 MCP 3006450 3 72/3 MCP 4506600 4 96/4 MCP 6006

800 150 1 35/1 MCP 1508200 1 35/ MCP 2008300 2 70/2 MCP 3008450 3 105/3 MCP 4508600 4 140/4 MCP 6008

Modular instrumentation panel, MIP

Front panel with cut outs for control, meters and network analyser.Material: 1.5 mm steel plate, powder structure paint RAL 7032.Pack quantity: 1 piece with mounting material.

N° of W cut outs DIM Cat.no.600 1 72x72 MIP 1506-1P

2 72x72 MIP 1506-2P92x92 MIP 1506-2G

4 72x72 MIP 1506-4P800 1 144x144 MIP 2006-1S

72x72 MIP 1508-1P2 72x72 MIP 1508-2P

92x92 MIP 1508-2G4 72x72 MIP 1508-4P1 144x144 MIP 2008-1S

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Page 20: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

20 Wall Mounting Enclosures

Accessories

Modular vertical support, ACM

Support kit for the mounting of the modular panels and DIN rails(PP1535) by steps of 150 mm. A space for equipment of 46 mm highis provided. Independent of the depth of the enclosure, the systemcould be used in combination with glazed door and a mounting plate isstill usable. 50 mm of space is provided for the equipment between thedoor and the panels.In order to allow an easy installation of the equipment and the wiring,the system can be assembled, fully equipped and pre-wired outside theenclosure, and then fitted into the enclosure. Cut-outs are provided onthe sides of the vertical profiles for wires routing.The kit contains two vertical profiles, top and bottom blanking platesand fixing material.Material: 1.5 mm steel plate, powder structure paint RAL 7032Pack quantity: 1 kit

Rows H W 50 mm Cat.no.

600 600 9 ACM 06060800 9 ACM 06080

800 600 15 ACM 08060800 15 ACM 08080

1000 600 18 ACM 10060800 18 ACM 10080

1200 600 21 ACM 12060800 21 ACM 12080

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Modular blank panel, MBP

Front blank panel to cover unused space or to mount special equip-ment.Material: 1.5 mm steel plate. Finish: powder structure paint RAL 7032Pack quantity: 1 piece with mounting material.

Rows W h 50 mm Cat.no.600 50 1 MBP 0506

100 2 MBP 1006150 3 MBP 1506200 4 MBP 2006300 6 MBP 3006450 9 MBP 4506600 12 MBP 6006900 18 MBP 9006

800 50 1 MBP 0508100 2 MBP 1008150 3 MBP 1508200 4 MBP 2008300 6 MBP 3008450 9 MBP 4508600 12 MBP 6008900 18 MBP 9008

Insulated Mounting Plates, AMI

H W Cat.no.250 250 AMI 02525300 250 AMI 03025

300 AMI 03030400 300 AMI 04030500 300 AMI 05030

400 AMI 05040600 400 AMI 06040

500 AMI 06050600 AMI 06060

700 500 AMI 07050800 600 AMI 08060

1000 600 AMI 10060800 AMI 10080

1200 600 AMI 12060800 AMI 12080

Made from 4 mm of insulating material.Packed quantity: 1 piece.

Fitted in the supports ACM orCMV allowing the fixing of theAMM mounting plate and adjustin depth between 60 and150 mm.Material: Made of 2.0 mm galva-nised steel.Pack quantity: 4 pieces withmounting material

Modular depth adjust, MD ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Cat.no.MD 4

Page 21: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

21Wall Mounting Enclosures

Accessories

Mounting plates, AMP

Material: 2.5 mm galvanized steel.Pack quantity: 1 piece.

H W Cat.no.200 200 AMP 02020250 200 AMP 02520

250 AMP 02525300 250 AMP 03025

300 AMP 03030600 AMP 03060800 AMP 03080

1000 AMP 031001200 AMP 03120

350 250 AMP 03525400 300 AMP 04030

400 AMP 04040500 AMP 04050600 AMP 04060

500 300 AMP 05030400 AMP 05040500 AMP 05050

600 400 AMP 06040500 AMP 06050600 AMP 06060800 AMP 06080

700 500 AMP 07050800 400 AMP 08040

600 AMP 08060800 AMP 08080

1200 AMP 081201000 600 AMP 10060

800 AMP 100801000 AMP 10100

1200 600 AMP 12060800 AMP 12080

1000 AMP 121001200 AMP 12120

1400 1000 AMP 14100

w

w - 50

h

h -

20

Telequick mounting plate, AMT

Simplifies installation and equipment fitting. Rectangular holes 26 x11 mm to obtain required fixing positions with snap-nuts. The nuts canbe moved around within the rectangular hole.Material: 2 mm galvanized steel.

H W Cat.no.250 250 AMT 02020300 300 AMT 03030400 300 AMT 04030

400 AMT 04040500 400 AMT 05040600 400 AMT 06040605 500 AMT 06050606 600 AMT 06060806 600 AMT 08060

1000 800 AMT 10080

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Spacer bolts, AMTE

For depth adjustment of the mounting plate.To be screwed on to the existing welded M-8 studs.provided for the mounting plate. Metric thread M8.Material: zinc plated steel.

Pack Length quantity Cat.no.

10 50 AMTE 801012 50 AMTE 801214 50 AMTE 801416 50 AMTE 801618 50 AMTE 801820 50 AMTE 802030 50 AMTE 803040 20 AMTE 804050 20 AMTE 805055 20 AMTE 8055

100 20 AMTE 8100

Snap nuts for telequick plates, TN

Packed quantity: 100 pieces.

Thread Cat.no.M 4 TN 04M 5 TN 05M 6 TN 06

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Page 22: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

22 Wall Mounting Enclosures

Accessories

Vertical mounting bars, AVB

25 mm hole pattern. To be used for the mounting of swing frames inpart of height. For other purposes CNM cage nuts can be used. Material: 2 mm galvanised steel.Pack quantity: 1 pair with mounting material.

H Cat.no.600 AVB 0600800 AVB 0800

1000 AVB 10001200 AVB 12001400 AVB 1400

Vertical mounting profiles (19”), AVP

For 600 mm wide enclosures. Fitted onto hinge holes in the front frameof the enclosure. Provides a distance between door and plates of56 mm. Requires AMG mounting plate guides for full adjustment indepth. Material: 2 mm galvanized plated steel.Pack quantity: 1 pair with mounting material.

N° of H units Cat.no.

600 12 AVP 0600800 17 AVP 0800

1000 20 AVP 10001200 26 AVP 1200

Lifting eyes, AL

Complies with DIN 580 lifting requirements.Packed quantity: 2 piece M-12 and mounting material.

Cat.no.AL 9301

Wall mounting brackets, AW

Material: 3 mm zinc plated steel.Equipped with 9 mm hole with a 9 mm hole for wall mounting.Pack quantity: 4 pieces with mounting material.

Cat.no.AW 4

DIN rails, PP

Galvanised steel. Environmental friendly at 15-20 microns.DIN rail according to EN 60715. Hole pattern 18 x 5.2 mmPack quantity: 2 m x 15.

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Mounting plate guides, AMG

To provide infinite depth adjustment for the mountingplate, the telequick plate or the profile mounting system.Material: zinc plated steel.Pack quantity: 2 pairs with fixing material.

D Cat.no.155 AMG 155210 AMG 210260 AMG 260300 AMG 300400 AMG 400

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Hole Dim. pattern Cat.no.5 x 15 10 PP 0515 H7 x 35 10 PP 07357 x 35 25 PP 0735 H

15 x 32 25 PP 153215 x 32 25 PP 1532 H15 x 35 25 PP 153515 x 35 25 PP 1535 H

Page 23: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

23Wall Mounting Enclosures

Accessories

Ventilated gland plates, AFG

1.5 mm louvered steel plate, pressed out 5 mm. Fitted with fly-net.Finish: structured powder paint, RAL 7032.Pack quantity: 1 piece with mounting material.

Cat.no.AFG 01AFG 02AFG 03AFG 04

Ventilated gland plates, AFR

1.5 mm louvred steel plate, pressed out 5 mm. Finish: structured powder paint, RAL 7032Pack quantity: 1 piece with mounting material.

Cat.no.AFR 01AFR 02AFR 03AFR 04

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Ventilated gland plates, AFV

1.5 mm louvered steel plate, pressed out 5 mm with filter.Finish: structured powder paint, RAL 7032.Pack quantity: 1 piece with mounting material.

Cat.no.AFV 01AFV 02AFV 03AFV 04

Adapter gland plates, AFA

Adapts AF type gland opening to the FL type.Material: 1.5 mm steel plate.Finish: structured powder paint, RAL 7032.Pack quantity: 1 piece with mounting material.

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Standard gland plates, AF

Flat gland plate for closing the standard gland opening.Material: 1.5 mm steel plateFinish: structured powder paint, RAL 7032.Pack quantity: 1 piece with mounting material.

Size Cat.no.0 AF 00

0S AF 00S1 AF 01

1S AF 01S2 AF 02

2S AF 02S3 AF 03

3S AF 03S4 AF 04

Gland plates with knock-outs, AFK

1.5 mm steel gland plate with knock-outs according to table.Finish: structured powder paint, RAL 7032.Pack quantity: 1 piece with mounting material.

PG opening:For

opening 16,5 20,5 25,5 32,5 Cat.no.210 x 96 4 4 2 2 AFK 11

12 _ 1 1 AFK 12310 x 96 9 5 2 2 AFK 21

21 _ 1 1 AFK 22410 x 96 18 5 4 2 AFK 31

21 10 _ _ AFK 32510 x 96 27 5 4 2 AFK 41

18 14 3 1 AFK 42210 x 56 4 3 _ _ AFK 11 S310x 56 6 3 1 _ AFK 21 S410 x 56 9 4 1 _ AFK 31 S

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

N° of FL Size openings Cat.no.

1 1xFL13 AFA 012 1xFL21 AFA 023 1xFL21 AFA 034 1xFL21 AFA 04

Page 24: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

24 Wall Mounting Enclosures

Accessories

To be used when combining an MAP enclosure with an MASor an MAD enclosure. Material: 10 mm polyethylene foam.Pack quantity: 2 gaskets with combining accessories.

For gland plate:Size Cat.no.

2 AGC 023 AGC 034 AGC 04

Gland plate gaskets, AG

For standard gland plates.Material: 5 mm thick polyethylene foam.Pack quantity: 1 piece with mounting material.

Size Cat.no.0 AG 00S1 AG 01

1 S AG 01 S2 AG 02

2 S AG 02 S3 AG 03

3 S AG 03 S4 AG 04

Combining gaskets, AGC

H W Cat.no.300 250 ADS 03025

300 ADS 03030400 300 ADS 04030500 400 ADS 05040600 400 ADS 06040

500 ADS 06050600 ADS 06060

700 500 ADS 07050800 600 ADS 08060

800 ADS 12080

Glazed door with clear glass, ADC

Fitted in place of the standard door, provides a clear view of the instru-mentation installed inside the enclosure.Protection: IP 55/NEMA 12.Material: 1.5/2.0 mm steel plate powder structure paint RAL 7032, with3 mm clear safety glass.Packed quantity: 1 piece.

H W Cat.no.300 250 ADC 03025

300 ADC 03030400 300 ADC 04030

400 ADC 04040500 400 ADC 05040600 400 ADC 06040

500 ADC 06050600 ADC 06060

700 500 ADC 07050800 600 ADC 08060

1000 600 ADC 10060800 ADC 10080

1200 600 ADC 12060800 ADC 12080

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Fitted in place of the standard door, provides a clear view of the instru-mentation installed inside the enclosure. Allows all the options of thelocking program. Protection: IP 55 and NEMA 12.Material: 1.5 mm/2 mm (from ADS 1008) steel plate, 3 mm smokedsafety glass.Finish: structured powder paint, RAL 7032. Pack quantity: 1 piece with mounting material.

Glazed doors with smoked glass, ADS

Page 25: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

25Wall Mounting Enclosures

Accessories

Glazed doors, ADT

Fitted in place of the standard door, provides a clear view of the ins-trumentation installed inside the enclosure. Allows all the options of thelocking program.Protection: IP 55.Material: 1.2/1.5 and 2.0 mm. steel plate powder structured paintRAL 7032, 3 mm transparent acrylic glass (PMMA).Packed quantity: 1 piece.

H W Cat.no.300 250 ADT 03025

300 ADT 03030400 300 ADT 04030

400 ADT 04040500 400 ADT 05040600 400 ADT 06040

500 ADT 06050600 ADT 06060

700 500 ADT 07050800 600 ADT 08060

1000 600 ADT 10060800 ADT 10080

1200 600 ADT 12060800 ADT 12080

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Glazed doors, ADA

To replace the standard steel door. Can be used in combination withswing frame, modular chassis or inner door. The 3 mm DIN lock can bereplaced by any optional insert or handle. Material: Anodised aluminium. Protection: IP 54. Acrylic glass 3 mm.Pack quantity: 1 piece with mounting material.

H W Cat.no.300 300 ADA 03030400 300 ADA 04030

400 ADA 04040600 ADA 04060

500 300 ADA 05030400 ADA 05040

Glazed doors, ADAB

To replace the standard steel door. Can be used in combination withswing frame, modular chassis or inner door. The 3 mm DIN lock can bereplaced by any optional insert or handle. Material: Anodized aluminium. Protection: IP 54. Acrylic glass 3 mm.Pack quantity: 1 piece with mounting material.

H W h w Cat.no.600 400 522 322 ADAB 06040

600 522 522 ADAB 06060800 522 722 ADAB 06080

700 500 622 422 ADAB 07050800 600 722 522 ADAB 08060

Display panels, ACA

For controls, meters, indication lamps etc. The mounted devices areprotected by a 29 mm (ADA)/56 mm (ADAB) high frame. The panel is3 mm thick and can be removed for drilling or screen printing. The3 mm DIN lock can be replaced by any optional insert or handle.Protecton: IP 54.Material: Anodized alumiuim.Pack quantity: 1 piece with mounting material.

H W h w Cat.no.300 300 226 226 ACA 03030400 300 326 326 ACA 04030

400 326 226 ACA 04040600 326 526 ACA 04060

500 300 426 226 ACA 05030400 426 326 ACA 05040500 426 426 ACA 05050

37

28.5

Ø35

75

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

37

63.5

Page 26: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

26 Wall Mounting Enclosures

Accessories

Display panels, ACB

For controls, meters, indication lamps etc. The mounted devices areprotected by a 29 mm (ADA)/56 mm (ADAB) high frame. The panel is3 mm thick and can be removed for drilling or screen printing. The3 mm DIN lock can be replaced by any optional insert or handle. Material: Anodized alumiuim.Protecton: IP 54.Pack quantity: 1 piece with mounting material.

H W Cat.no.600 400 ACB 06040

600 ACB 06060800 ACB 06080

700 500 ACB 07050800 600 ACB 08060

800 ACB 080801000 600 ACB 10060

800 ACB 100801200 600 ACB 12060

800 ACB 12080

Used for the mounting of standard modules with maximum height of68 mm by steps of 125 mm. If required, the standard door can bereplaced with the glazed doors ADA, ADB or ADT.The delivery includes: a slotted front plate and two vertical profiles, topand bottom blanking plates with one DIN rail per row and fixing mate-rial.Material: DIN Rails PP 0735 made of 1.5 mm galvanized steel, rest1.5 mm steel plate painted RAL 7032

N° of N° of H W rows modules Cat.no.

300 250 2 16 AC 03025400 300 3 33 AC 04030500 400 3 48 AC 05040600 400 4 64 AC 06040

600 4 108 AC 06060700 500 5 110 AC 07050800 600 6 162 AC 08060

Inner doors, ADI

For controls, meters, lamps etc. Can be left or right hand hinged. Usable depth: 35 mm. Usable opening: H-55, W-108.Material: 1.5 mm steel plate.Finish: structured powder paint, RAL 7032.Pack quantity: 1 piece with mounting material.

H W Cat.no.400 300 ADI 04030500 400 ADI 05040600 400 ADI 06040

600 ADI 06060700 500 ADI 07050800 600 ADI 08060

1000 600 ADI 10060800 ADI 10080

1200 600 ADI 12060800 ADI 12080

Door stop, ADO

To secure the door in an open position allowing it opened at 90° and110°.Mounted to directly to the doorframe.Material: Zinc plated steel.Pack quantity: 1 piece with mounting material.

Cat.no.ADO 200

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Modular chassis, AC ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

55.5

63.5

Page 27: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

27Wall Mounting Enclosures

Accessories

Lock cover, ALC

With grip on both sides (without insert).Pack quantity: 1 piece.

Cat.no.ALC 500

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Door switch, ADSW

To activate any electrical devices (e.g. LTC, signalling or alarming, etc.)Supplied with a support for fitting to both the left and right hand side ofthe enclosure. Also possible to fit in combination with the door frame.Cable entry PG 13,5. UL and CSA approved.Switching load 6A-230V.Packed quantity: 1 piece

Cat.no.ADSW 01

Door mounting profiles, ADV

To be fitted on the inside of the door. 1.5 mm galvanised steel.Dimensions: 15 x 10 mm.Pack quantity: 1 pair, with mounting material.

H Cat.no.200 ADV 020250 ADV 025300 ADV 030400 ADV 040500 ADV 050600 ADV 060700 ADV 070800 ADV 080

1000 ADV 1001200 ADV 1201400 ADV 140

Document pocket, DRA

Self adhesive, for DIN A4 format. Usable depth: 30 mm.Colour: greyMaterial: Thermoplastic

Cat.no.DRA 04

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Floor stands, PFF

End pieces for floor mounting to give a suitable operation level.Suits all 300 and 400 mm deep enclosures. 300 or 450 mm high.Material: 2 mm steel plate, powder structure paint, RAL 7032.Pack quantity: 1 piece with mounting material.

H D Cat.no.300 300 PFF 330450 300 PFF 345300 400 PFF 430450 400 PFF 445

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Modular mounting plates, AMM

Fitted in the MD support allowing fixing of universal MCCB up to 400 Aof any manufacturer.Material: Made from 2.5 mm galvanised steel.Packing Material: 1 piece.

N° of rows W Cat.no.

4 600 AMM 6046 600 AMM 6069 600 AMM 6094 800 AMM 8046 800 AMM 8069 800 AMM 809

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Page 28: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

28 Wall Mounting Enclosures

Accessories

Locks, ALL

Pack quantity: 1 piece.

Keys, ALK

Pack quantity: 1 piece.

Description Cat.no.Square 7 mm ALK 523Square 8 mm ALK 524Triangular 7 mm ALK 526Triangular 8 mm ALK 527

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Description Type Cat.no.Standard lock, DIN 3 mm DIN 3 mm ALL 503Slam/Push lock, DIN 3 mm DIN 3 mm ALL 504Cylinder lock

Ronis key n° C21323 for ADA/ACA ALL 506Ronis key n° C21323 for ADAB/ACB ALL 507Ronis key n° C21323 ALL 508

Inserts, ALI

Pack quantity: 1 piece.

Description Cat.no.DIN 3 mm ALI 503DIN 5 mm ALI 505Square 7 mm ALI 523Tirangular 8 mm ALI 524Square 8 mm ALI 525Triangular 7 mm ALI 526Slotted 2x4 mm ALI 528

Handles, ALT

Pack quantity: 1 piece.

Description Cat.no.Chrome plated T-handle with cylinder lock ALT 560Chrome plated handle with cylinder lock ALT 561Chrome plated handle with cylinder lock, ALT 562Plastic handle ALT 563

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Page 29: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

29Wall Mounting Enclosures

Accessories

Roof, ARF

To be fitted as an outdoor shelter on single mounted enclosures. Theroof is slightly tilted and has a drip-strip.Made from 1.5 mm steel plate, painted RAL 7032.

W D Cat.no.250 155 ARF 02515

210 ARF 02521300 155 ARF 03015

210 ARF 03021400 155 ARF 04015

210 ARF 04021260 ARF 04026300 ARF 04030

500 155 ARF 05015210 ARF 05021260 ARF 05026300 ARF 05030

600 210 ARF 06021260 ARF 06026300 ARF 06030400 ARF 06040

800 210 ARF 08021260 ARF 08026300 ARF 08030400 ARF 08040

1000 300 ARF 100301200 300 ARF 12030

400 ARF 12040

Plinth front/back panels, P

The plinth consists of four corner pieces with removable front covers.The side panels PS are to be ordered separately. Height 100 and200 mm. Material: 2.5 mm steel plate for corners, painted RAL 7022.1.5 mm steel plate for U-section, painted in RAL 7022.Pack quantity: 1 set

H W D Cat.no.100 400 100 P 1040

600 100 P 1060800 100 P 1080

1000 100 P 11001200 100 P 1120

200 400 200 P 2040600 200 P 2060800 200 P 2080

1000 200 P 21001200 200 P 2120

Plinth side panels, PA

Two U-section side pieces for height 100 and 4 U-section for 200 mm.Material: 1.5 mm steel plate, painted RAL 7022 Pack quantity: 1 set

H D Cat.no.100 260 PA 1026

300 PA 1030400 PA 1040

200 260 PA 2026300 PA 2030400 PA 2040

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Page 30: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

30 Wall Mounting Enclosures

Polyester enclosures

IP 65

HZP, HZPT, Polyester enclosures

Material: Fibre glass reinforced polyester.Self extinguishing according to IEC 695 2-1.Flammability according to UL 94 HB.Temperature resistance from - 40° Cto +130° C(Class B, IEC 85)Superficial resistivity 1012 Ohm cm.Electrical resistivity >50 MOhm.Impact resistance 20 Joule.Double isolated according to EN 60439-1.Body: Monoblock moulded 3 mm thick, with rear fixing holes.Door: With or without window (polycarbonate 3 mm thick).Lock: 3 mm pin DIN lock.Mounting plate: Available as an accessory in 3 versions: steel,polyester or perforated steel.Gland plate opening: No gland plate opening. Cable accesstotally variableFinish: RAL 7035.Protection: Corresponds with IP 65 and NEMA 4 X.Delivery includes: Wall brackets and fixing screws.

Plain doorH W D Cat.no.

300 250 140 HZP 325400 300 200 HZP 430

400 200 HZP 440500 400 200 HZP 540600 400 230 HZP 640

500 230 HZP 650800 600 300 HZP 860

Polyester mounting plate, HZBP

Made from 4 mm thick polyester.

H W h w Cat.no.300 250 268 213 HZBP 325400 300 358 260 HZBP 430

400 358 360 HZBP 440500 400 458 360 HZBP 540600 400 558 360 HZBP 640

500 558 460 HZBP 650800 600 754 556 HZBP 860

Telequick mounting plate, HZBR

Simplifies installation and equipment fitting.Rectangular holes 26 x 11 mm to obtain required fixing position withsnaps-nuts. The nuts can be moved around within the rectangular hole.Material: 2 mm zinc plated steel. Snap nuts (TN4, TN5 and TN6) canbe founded in MAS enclosure accessories section.

H W Cat.no.30 0 250 HZBR 325400 300 HZBR 430

400 HZBR 440500 400 HZBR 540600 400 HZBR 640

500 HZBR 650800 600 HZBR 860

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Material: 2 mm zinc plated steel plate

H W h w Cat.no.300 250 268 213 HZBZ 325400 300 358 260 HZBZ 430

400 358 360 HZBZ 440500 400 458 360 HZBZ 540600 400 558 360 HZBZ 640

500 558 460 HZBZ 650800 600 754 556 HZBZ 860

Steel mounting plate, HZBZ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Transparent doorH W D Cat.no.

300 250 140 HZPT 325400 300 200 HZPT 430

400 200 HZPT 440500 400 200 HZPT 540600 400 230 HZPT 640

500 230 HZPT 650800 600 300 HZPT 860

Page 31: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

31Wall Mounting Enclosures

Accessories

Mounting plate guides, HZDP

To provide infinite depth adjustment for themounting plates, the telequick plate or themodular chassis.Material: Zinc plated steel. Pack quantity: 2pairs with fixing material.

D Cat.no.200 HZDP 200230 HZDP 230300 HZDP 300

Closing plates, HZE

To cover open space in HZIP.Finish: RAL 9002. 3 plates of 1 module and 2 plates of 0,5 modules.Pack quantity: Set of 10 pieces.

Cat.no.HZE 1

Swinging mounting plate, HZID

Can be left or right hand hinged. Adjustable depth position. Material: 2 mm polyester.Pack quantity: 1 piece with mounting brackets kit.

H W Cat.no.400 300 HZID 430

400 HZID 440500 400 HZID 540600 400 HZID 640

500 HZID 650800 600 HZID 860

Modular chassis, HZIP

Complete kits of easy assembly for rapid mounting of modular switch-gear components (17.5 mm module).Adjustable depth for 5 different components heights(maximum 66 mm). PVC front plate.Delivery includes: one complete chassis with DIN rails and a front plate.

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Lock interlocking, HZCC

Padlock.Pack quantity: one piece.

Cat.no.HZCC 01

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Inner doors, HZPI

Can be left or right hand hinged. 90° opening.Material: reinforced polyester.Pack quantity: 1 door with mounting material

H W Cat.no.400 300 HZPI 430

400 HZPI 440500 400 HZPI 540600 400 HZPI 640

500 HZPI 650800 600 HZPI 860

N° of N° mod H W rows 17,5 mm. Cat.no.400 300 2 x 12 24 HZIP 4302

2 x 18 36 HZIP 4303400 3 x 18 54 HZIP 4402

3 x 18 54 HZIP 4403500 400 3 x 23 69 HZIP 5403600 400 4 x 29 116 HZIP 6404

500 5 x 29 145 HZIP 6504

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Wall mounting bracket, HZCT

Set of 4 wall brackets providing 20 mm of clearancebetween the enclosure and the wall. Allows the insertion of wires andtubes. Pack quantity: 4 pieces.

Cat.no.HZCT 04

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Page 32: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

32 Wall Mounting Enclosures

Accessories

Inserts, HZPTT

Triangular insert with plastic key.

Cat.no.HZTT 01

Inserts, HZBD

3 mm DIN insert with plastic key

Cat.no.HZBD 01

Cylinder lock, HZCM

Wing-handle with cylinder lock and key.

Cat.no.HZCM 01

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Page 33: EXP WALL 01-33 - dart- · PDF fileANSI/EIA-310-C-77 Racks panels and accosted equipment. ... RAL 7035 Pack. quantity:1 piece With transparent cover ... 28 28 27 DSHI 1 E Blind plug,

33Wall Mounting Enclosures