19
Centre for Research & Technology Hellas Centre for Research & Technology Hellas Information Technologies Institute Information Technologies Institute DG CONNECT & ETSI 4 th Workshop on Smart Appliances Exercising SAREF mapping on DER Exercising SAREF mapping on DER Exercising SAREF mapping on DER Exercising SAREF mapping on DER level in INERTIA project level in INERTIA project Mr. Dimosthenis Ioannidis Senior Researcher & Project Manager [email protected] P: +30 2311 257 750

Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

Centre for Research & Technology Hellas Centre for Research & Technology Hellas Information Technologies InstituteInformation Technologies Institute

DG CONNECT & ETSI 4th Workshop on Smart Appliances

Exercising SAREF mapping on DER Exercising SAREF mapping on DER Exercising SAREF mapping on DER Exercising SAREF mapping on DER level in INERTIA projectlevel in INERTIA project

Mr. Dimosthenis IoannidisSenior Researcher & Project Manager

[email protected]: +30 2311 257 750

Page 2: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITIOutlineOutline

1. INERTIA FP7 Project2. INERTIA Device Ontology - Existing Approach3. Use Case: INERTIA Light Switch4. SAREF New Device Sub-Class: Light4. SAREF New Device Sub-Class: Light5. Possible Extensions

1. INERTIA Dishwasher2. HVAC 3. Generation Units4. Occupancy5. Conclusions

4th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 20152

Page 3: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITIINERTIA FP7 ProjectINERTIA FP7 Project

• INERTIA, Integrating Active, Flexible and Responsive Tertiary Prosumers into a Smart Distribution Grid, FP7 EU Project

• Pilot Site at CERTH Building in Thessaloniki, Greece

• Multi-sensorial installation collecting Energy

34th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 2015

• Multi-sensorial installation collecting Energy Consumption, Environmental and Occupancy Information

• DER monitoring and control through REST interfaces based on INERTIA Device ontology built for the scope of the project

• Use-case examples for the saref ontology implementation and possible extensions identified

Page 4: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITI

INERTIA Device OntologyINERTIA Device Ontology--Existing Existing Approach Approach (1/2)(1/2)

• INERTIA Ontology describes three main domains addressed in the building context:

�Location

�Devices

�Occupants�Occupants

• Refers to the Energy-related BIM model and correlates Distributed Energy Resources with Sensors/Actuators

• Describes DERs such as HVACs, Lightning etc.

• Describes the WSN with a wide set of SensorActuator sub-classes representing the installed equipment.

• Application-based ontology to cover specific needs of the project

4th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 2015

Page 5: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITI

INERTIA Device OntologyINERTIA Device Ontology--Existing Approach Existing Approach (2/2)(2/2)

54th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 2015

Part of Device Taxonomy The schema of INERTIA Device Ontology

Page 6: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITI

Light Actuator INERTIA Configuration Requirements

SAREF Ontology

Type (e.g. ON/OFF, dimming etc.) •saref: hasModel string•saref:hasCategory saref:DeviceCategory

Measurement range Event reporting interval

•saref:Open_close_function•saref:Metering Function

Use Case: INERTIA Light Switch (1/4)Use Case: INERTIA Light Switch (1/4)

Location of actuator •saref:isLocatedIn saref:BuildingSpace(BuildingSpace class contains the Device and the space type FIEMSER Ontology)

Functions (ON/OFF set & statusmonitor, consumption)

•saref:hasFunction saref:Open close Function saref:On_off_functionsaref:Sensing Function

Operation Status ON/OFF saref: hasState saref:state

Consumption value saref: Power

Dimming Factor rate (if applicable) No dimming factor. Possible extension dimming factor state

4th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 2015

Page 7: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITI

Visual Representation of SAREF

Use Case: INERTIA Light Switch (2/4)Use Case: INERTIA Light Switch (2/4)

4th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 2015

Page 8: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITIUse Case: INERTIA Light Switch(3/4)Use Case: INERTIA Light Switch(3/4)

Visual Representation of Light Switch

functions

4th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 2015

Page 9: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITI

Visual Representation of Metering Function accomplished by Light_Switch

Use Case: INERTIA Light Switch (4/4)Use Case: INERTIA Light Switch (4/4)

Visual Representation of Open_Close_Function accomplished by Light_Switch

4th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 2015

Page 10: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITISAREF New Device SubSAREF New Device Sub--Class: Light (1/3)Class: Light (1/3)

Light INERTIA Configuration Requirements

SAREF Ontology

Type (e.g. fluorescent, CFL etc.) saref: hasModel stringsaref:hasCategory

Rated Power saref:hasTypicalConsumption

Location of Device saref:isLocatedIn to a BuildingSpace class that contains Location of Device saref:isLocatedIn to a BuildingSpace class that contains the Device and the space type inverse property -FIEMSER Ontology

Correlation with monitoring and/or control sensors

Accomplished through the location (by choosing the proper granularity levels) OR saref:consistOf saref:Device

Control type (e.g. dimming, ON/OFF)

Accomplished through the location (by choosing the proper granularity levels) OR saref:consistOf saref:Device

Operation Status ON/OFF saref: hasState saref:state

Consumption value saref: hasProfile saref:Profile

Dimming Factor rate (if applicable) No dimming factor. Possible extension dimming factor state

4th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 2015

Page 11: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITISAREF New Device SubSAREF New Device Sub--Class: Light (2/3)Class: Light (2/3)

Visual Representation of SAREF

4th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 2015

Page 12: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITISAREF New Device SubSAREF New Device Sub--Class: Light (3/3)Class: Light (3/3)

Visual Representation of Light Device

4th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 2015

Page 13: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITI

• INERTIA Smart Dishwasher (INDESIT partner reference implementation) to operate as Smart Energy Appliance according to specific operation profiles

• Communication protocol Energy@home project

• Wide variety of services: from simple awareness up to a

Possible ExtensionsPossible Extensions--INERTIA Dishwasher (1/2)INERTIA Dishwasher (1/2)

• Wide variety of services: from simple awareness up to a fully integrated Energy Management System.

• 4th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 2015

• The Dishwasher supports remote START/STOP of a cycle

• The Appliance Power Profile (APP) estimates power of cycle over time and relevant energy consumption

• Run-time correction of the energy phase duration when cycle is running

Page 14: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITIPossible ExtensionsPossible Extensions--INERTIA Dishwasher (2/2)INERTIA Dishwasher (2/2)

INERTIA Dishwasher Properties

Current Energy Phase

Remaining Total Time

Remaining Total Energy Usage

Estimated Energy Usage for next15Mins

• BIM allocation of the Dishwasher

• The Dishwasher properties should be retrieved via GET command

Estimated Peak Power for next 15Mins

Current Status of the appliance

Current Power

Total Energy Consumption consumed during operation cycles

command

• Commands to be applied:

� Start

� Stop

� Pause

� Washing start time

� Phase delay time

SAREF Washing Machine sub-class extension to further adapt in more

complex examples

4th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 2015

Page 15: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITIPossible ExtensionsPossible Extensions--HVACHVAC

• HVAC system consisting of external (VRV units) and internal units

• BIM allocation of both external and internal units

• External units correlated with

INERTIA HVAC system Properties

Configuration parameters (rated power, cooling/heating capacity, cooling/heatingefficiency)

Current Operational Status (ON/OFF)• External units correlated with their internal units

• The HVAC properties should be retrieved via GET command

• Commands to be applied:

� Turn on

� Turn off

� Set temperature set point

Current Operational Status (ON/OFF)

Current Power Consumption

Actual Temperature

Temperature Set Point

User Control On Off (ACTIVE/PASSIVE)

User Control Temperature Set Point (ACTIVE/PASSIVE)

4th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 2015

Page 16: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITIPossible ExtensionsPossible Extensions--Generation UnitsGeneration Units

INERTIA Generation Units Properties

Configuration Parameters (nominal power, minimum/maximum capacities)

Connection status (Connected/ Disconnected)

Active Power Set point

• Except for consumption devices a list of generation/storage devices are considered

� Photovoltaic panels Active Power Set point

Current Active Power

Current capacity

Charging status

Producing or Consuming mode (only for storage devices)

� Photovoltaic panels

� Batteries (EVs, PVs)

� Power Generators

• Commands to be applied:

� Connect

� Disconnect

SAREF Device sub-class extension to represent generation/storage units

4th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 2015

Page 17: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITI

• Occupancy aspects affect the usage of specific devices (e.g. Office and Home Appliances)

• The occupancy modelling is combined with occupancy detection systems, i.e RFID, to

Possible ExtensionsPossible Extensions--OccupancyOccupancy

detection systems, i.e RFID, to better correlate device applied actions with human presence

• Occupancy Modelling Concept

� Each Occupant is correlated with personal appliances

� Each Occupant is correlated with a location

4th Workshop on Smart Appliances Presentation, Brussels - Belgium, April 2015

Page 18: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITI

– Extension of available subclasses to address a wider variety of instances (complex devices, generation units)

– Parameters such as Temperature, utilization rates, could affect Energy profiles of other devices i.e. HVAC systems, thermostatic appliances

– Extension of Units of Measurement (Humidity units, C02 rate, occupant

Possible ExtensionsPossible Extensions--ConclusionsConclusions

– Extension of Units of Measurement (Humidity units, C02 rate, occupant units etc.) for environmental and occupancy sensors

– Property saref:consistsOfDevice could be more generic (e.g. saref:hasDevice) to address the concept of different sensors/actuators attached to DERs e.g. A light monitored and controlled by a dimming sensor

– Extension of available functions/services (e.g. add phase delays for Washing Machines)

– Occupancy aspects could be taken into consideration

Page 19: Exercising SAREF mapping on DER level in INERTIA projectdocbox.etsi.org/Workshop/2015/201504_SMARTAPPLIANCES4/Exerc… · Thank you for your attention ! Dimosthenis Ioannidis E--mail:

CERTH/ITICERTH/ITI

Thank you for your attention !

Dimosthenis IoannidisDimosthenis IoannidisEE--mail: [email protected]: [email protected]

Centre of Research & Technology Centre of Research & Technology -- HellasHellasInformation Technologies InstituteInformation Technologies Institute

attention !