EVITA® OXYDissolved Oxygen Meter

DANFOSS ANALYTICAL - COMPLEXITY MADE SIMPLE

Page 2: EVITA - Tripod.comstates1.tripod.com/literature/EvitaOxydata.pdf · Maintenance at a minimum Perhaps the greatest benefit obtained with the EVITA® OXY sensor is that maintenance

Long meter cables- the two-wire 4-20 mA HART® transmitter allows up to 3,000 ft between transmitter and display/PLC

For installation everywhere - the EVITA® OXY transmitter isintrinsically safe, approved by bothCENELEC and UL

Built-in auto calibration- a tilt-switch function initiates anautomatic calibration sequence whenthe sensor is tilted or turned over

How it worksThe EVITA® OXY dissolved oxygen meter operates onClark’s principle:

• To initiate measurement a polarization voltage is appliedbetween two electrodes. Gold is used as cathode anda silver wire as anode, both placed in an electrolyticsystem separated from the liquid by a gas permeablediaphragm.

• Oxygen molecules penetrating the diaphragm areattracted to the positively charged gold cathode.

• A small electric current is thereby establishedbetween the gold cathode and silver anode.

• The transmitter converts this current into a usable 4-20 mA signal.

Automatic cleaning- the self-cleaning ball float with

specially designed fins keeps the sensorclean for months - reducing

maintenance time to a minimum

High reliability and accuracy

- a prestressed, bonded diaphragm ensures predictable

permeability at changing temperatures and prevents

contamination of the electrolyte

Increased sensor life- an 18” silver wire is used to

make the surface area of the anode as large as

possible, increasing operating life to 2-3 years

Real diaphragmpuncture detection - the diaphragm is

constantly monitored and anyrupture or other source of

leakage is instantly detected

High accuracy and noise immunity- the 4-20 mA HART® transmitter is mounted directly behind the oxygen sensor and temperature sensor, ensuring high accuracy and noise immunity

Page 3: EVITA - Tripod.comstates1.tripod.com/literature/EvitaOxydata.pdf · Maintenance at a minimum Perhaps the greatest benefit obtained with the EVITA® OXY sensor is that maintenance

Maintenance at a minimumPerhaps the greatest benefit obtained withthe EVITA® OXY sensor is that maintenanceis reduced to a minimum:

• We have perfected what we invented 20 years ago by adding four fins to themeter design – further improving theself-cleaning effect.

• There is no need for grinding stones, fresh water, chemicals etc.

• When cleaning is necessary after 2-3 months of operation in the aeration tank, all you need to do is wipe thesensor with a cloth.

Flexible communicationChoosing the right communicationprotocol for your equipment can bedifficult: Which protocol will meet the

requirements for the years to come?Danfoss has met this challenge by makingthe EVITA® OXY meter extremely flexible.

• You can choose the communication module that fits your needs today and change it later when new protocols are developed.

• Individual modules with differentcommunication protocols can be mounted in the USC 6000 signalconverter without any use of tools.

• The OXY 4100/4150 transmittercommunicates with either the USC 5000/6000 signal converter or a PLCvia HART® communication, usingonly two wires.

New ball float design- the special fins increase turbulence and keep the sensor clean for typically 2-3 months

Automatic cleaning - after three months of operationin an aeration tank the sensor isstill measuring accurately

Page 4: EVITA - Tripod.comstates1.tripod.com/literature/EvitaOxydata.pdf · Maintenance at a minimum Perhaps the greatest benefit obtained with the EVITA® OXY sensor is that maintenance

Automatic calibrationThe EVITA® OXY is extremely easy to use.There is no need for special cables, no com-plicated diagrams to follow, and calibration isperformed automatically.

• Simply press a button and the system cali-brates itself within minutes. Alternatively, just tilt the transmitter: a tilt switch will initiate calibration.

• There is no need to calibrate the zero pointeither. The low-cost disposable OXY 1100sensor can be exchanged before zero-pointcalibration becomes necessary.

• The automatic calibration function ensuresthat EVITA® OXY remains as accurate as the day you installed it.

Oxygen profile control – a money saverThere can be large fluctuations in the oxygenconcentration anywhere in an aeration tank.By installing several oxygen meters in eachtank, the oxygen profile can be evened out,energy can be saved and the process becomesbetter tuned to fluctuations in the BOD load.

• The EVITA® OXY 4100/4150 transmitteris a cost-saving system for oxygen profile control. You can connect up to 15 trans-mitters to one PLC using only two wires and the HART® communication multidropmode to transmit oxygen concentrations.

Replacement in five minutesAll dissolved oxygen meters require regularsensor replacement. Danfoss has made thisprocess so simple that it can be performedin five minutes – with no mistakes possible.

• The EVITA® OXY monitors sensor life and alerts you the moment replacement is required.

• Simply unscrew the collar that holds the sensor in place and insert the new sensor. Spare sensors can be stored indefinitely without diminishing performance. It only starts to operate when connected to the transmitter.

ppm

days

ppm

days0 0

Page 5: EVITA - Tripod.comstates1.tripod.com/literature/EvitaOxydata.pdf · Maintenance at a minimum Perhaps the greatest benefit obtained with the EVITA® OXY sensor is that maintenance

TRANSMITTER OXY 4100 OXY 4150

Measuring range Dissolved oxygen: 0 to 10 - 500% Dissolved oxygen: 0 to 10 - 500%

0 to 0.1 - 50 mg/l or ppm 0 to 0.1 - 50 mg/l or ppm

Temperature 32°F to 160°F Temperature 32°F to 160°F

Measuring uncertainty Oxygen: ± 0.5%, Temperature: ± 0.2°F Oxygen: ± 0.5%, Temperature: ± 0.2°F

Current outputs 4-20 mA (scaleable by HART®), galvanic isolation 4-20 mA (scaleable by HART®), galvanic isolation

Max load: 750 ohm @ 30 VDC Max load: 750 ohm @ 30 VDC

Enclosure NEMA 6P NEMA 6P

Ambient temperature Storage: -40°F to +160°F Storage: -40°F to +160°F

Operation: -40°F to +140°F Operation: -40°F to +140°F

Media: 32°F to +122°F Media: 32°F to +122°F

Power supply 12-30 VDC 12-30 VDC

Automatic calibration Compensating for temp. (pressure, salinity, Compensating for temp. (pressure, salinity,

and humidity by entering values using HART®) and humidity by entering values using HART®)

Approvals UL, CE and C-tick approved UL, CE and C-tick approved

EEx ia IIB T4 (CENELEC) intrinsically safe EEx ia IIB T4 (CENELEC) intrinsically safe

Emission: EN 50081-1, Immunity: EN 50082-2 Emission: EN 50081-1, Immunity: EN 50082-2

SIGNAL CONVERTER USC 5000 USC 6000

Measuring range Dissolved oxygen: 0 to 10 - 500% Dissolved oxygen: 0 to 10 - 500%

0 to 0.1 - 50 mg/l or ppm 0 to 0.1 - 50 mg/l or ppm

Temperature 32°F to 160°F Temperature 32°F to 160°F

Measuring uncertainty Oxygen: ± 0.5%, Temperature: ± 0.2°F Oxygen: ± 0.5%, Temperature: ± 0.2°F

Current outputs One 4-20 mA (scaleable), galvanic isolation Two 4-20 mA (scaleable), galvanic isolation

Max load: 800 ohm Max load: 800 ohm

Relay outputs None 3 relay outputs SPST (48 V d.c. 4A)

Display Back-lit alphanumeric LCD display Back-lit alphanumeric LCD display

Enclosure Converter module: NEMA 6 Converter module: NEMA 6, Rack Mount: NEMA 1

Ambient temperature Storage: -40°F to +160°F Storage: -40°F to +160°F

Operation: -40°F to +140°F Operation: -40°F to +140°F

Power supply 115-230 VAC +10% - 15%, 50/60 Hz, 5 VA 115-230 VAC +10% - 15%, 50/60 Hz, 5 VA

11-30 VDC

Automatic calibration Compensating for temperature, barometric Compensating for temperature, barometricpressure, humidity and salinity pressure, humidity and salinity

Approvals UL, CE and C-tick approved UL, CE and C-tick approved

Emission: EN 50081-1, Immunity: EN 50082-2 Emission: EN 50081-1, Immunity: EN 50082-2

OXY 1100 sensor Mounting bracket

Principle Replaceable Clark sensor measuring dissolved Bracket mounted on handrail with pivot

oxygen. Typical life 2-3 years function to hold 1 1/2” PVC pipe

Working temperature Storage: 32°F to +160°F Storage: -40°F to +160°F

Media: 32°F to +122°F Operation: -40°F to +160°F

Material Diaphragm: 50µm FEP Teflon® Base: Stainless steel

Cathode: Gold, Anode: Silver, Electrolyte: KCl Holder: Carbon & fibreglass reinforced polyamide

Weight 0.5 Oz 1.75 lbs

Page 6: EVITA - Tripod.comstates1.tripod.com/literature/EvitaOxydata.pdf · Maintenance at a minimum Perhaps the greatest benefit obtained with the EVITA® OXY sensor is that maintenance

ISO 14001ISO 14001

DKCFE.PB.200.B3.22 / 521B0029 Produced by Danfoss G1 advertising agency 01.01.APH.JN.AO

Purchasing Danfoss products gives you not onlyhigh quality and unsurpassed reliability, but also alasting partnership that will always provide you withthe technology of tomorrow.

Danfoss is well-known for accurate mechanical andelectronic systems, and is perhaps even morerenowned for its intelligent, mechatronic products.Water treatment processes always have been a vitalpart of our business, and today our commitment tothe water and wastewater industry is stronger thanever.

Our wastewater product offering includes flowme-ters, water valves, pressure transmitters and frequen-cy converters. Supplemented with the EVITA®

INSITU colorimetric nutrient sensors and EVITA®

OXY dissolved oxygen meters, we believe our manyproducts make calling Danfoss worthwhile.

Partnership with commitment

Flowmeterswww.danfoss.com/instrumentation

Water valveswww.watervalves.com/uk

VLT® Frequency converterswww.danfoss.com/drives

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also appliesto products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Danfoss Water& Wastewater Division8800 W. Bradley RoadMilwaukee, WI 53224-9541Phone: 1 414 355 8800Fax: 1 414 355 6117www.us.water.danfoss.com

Davis Controls Limited2200 Bristol CircleOakville, Ontairo L6H 5R3CanadaPhone: (905) 829-2000Fax: (905) 829-2630

EVITA ® Nutrient sensorswww.danfoss.com/analytical