  • Everybody said: That‘s impossible. Then someone came who didn‘t

    know that and simply did it.

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 2 -

    MICRO WATER PLANT

    Our mission is to provide all people in need with access to clean drinking wa-ter. Clean drinking water is a human right and we want to help all people to sa-tisfy one of their most important basic needs. The human being is our priority.

    M.W.P. supplies clean drinking water under diffi cult conditions

    1. Ready to run2. Simple operation3. Easy cleaning and maintenance

    Delivered in two boxes in the practical euro-pallet format:

    Box 1 contains the mobile water treatment plant

    Box 2 contains further functional and spare parts

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 3 -

    INDEX

    The problem ...............................................................04

    The solution ................................................................05

    The functionality .......................................................06

    M.W.P. - Box 1 and Box 2 ..........................................07

    Function/Treatments ................................................08

    Function/Structure ....................................................09

    Commissioning ...........................................................12

    Laboratory values ......................................................14

    Delivery Rate ..............................................................16

    M.W.P. Mission in Ghana ...........................................17

    M.W.P. Mission in Peru ..............................................18

    Running costs .............................................................19

    Contact ........................................................................21

    Pricing and terms of delivery ..................................21

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 4 -

    THE PROBLEM

    Irrespective of the scenario:Due to structural problems, catastrophes and wars - the most important thing is missing in many parts of the world:

    clean drinking water

    Until now solutions were mainly based on reverse osmosis installa-tions whereby units with an output range of between 750 and 900 litres per hour easily fi ll a 20’ container. In addition to the complex transport logistics further problem areas are high energy require-ments and high maintenance costs.

    Problem & Solution

    the problem

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 5 -

    THE SOLUTION

    the solution

    M.W.P. was developed to provide people who have to live in an environment where water is only available in inferior quality with clean, germ-free drinking water in an inexpensive and uncomplica-ted way.

    M.W.P. is ideal for the perfect clarifi cation of cloudy, salt-free wa-ter contaminated with germs or chemicals. By using an additional sand fi lter, which can easily be built on site, even heavily contami-nated water can be converted back into drinking water by M.W.P.

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 6 -

    THE FUNCTIONALITY

    M.W.P. works on the basis of a precipitation, UV and fi lter units. This results in the following advantages compared to the usual reverse osmosis plants:

    extremely compact and therefore easy to transport

    output performance at least 900 litres/hour

    extremely low priced both in acquisition cost as also in running costs

    Maintenance without in-depth special knowledge through simple construction

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 7 -

    M.W.P. - BOX 1 AND BOX 2

    Box 1 – Contents

    • M.W.P. - the mobile water treat-ment plant (the components are fi rmly screwed into the plastic box)

    • 10 m electrical cable for connecti-on to socket or emergency power generator

    • 10 m water hose for connection to included dirt pump

    • 5 m drinking water hose with quick-release fastener

    • Water tap for placing on the hose

    Size: H 940 x W 1200 x D 800 mmWeight: 135 kg

    The outer box is made of P.P. plastic (food safe).

    M.W.P. is delivered in two components:

    Box 2 – Contens

    • emergency generator (Petrol 230V)• submersible pump• Petrol canister (UN approval)• spout• 6x fl occulant 4 litres

    Spare parts:• UV lamp (42 V)• spare fi lter bag• Replacement membrane for

    water pump• 2x fi lter mats• fi lter key

    Size: H 940 x W 1200 x D 800 mmWeight: depending on equipment

    The outer box consists of P.P. plastic (food safe).

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 8 -

    FUNCTION/TREATMENTS

    The following treatment steps are applied in the MWP:

    1. Precipitation. Coagulation of any suspended matters in the wa-ter (>0.1µm) e. g. oils, grease, impurities etc. to particle size >40 µm, which are then removed by fi lter sponges.

    2. UV treatment: disinfection (99.9%)

    3. Fine fi ltration with: PCW – PF MWP: Silver as an agent/ birm/ zeolith/ active carbon: Fine purifi cation/ iron, heavy metals, ammonium, caesium, strontium/ drug residues, hormones, fl u-orides, trihalomethanes, lead particles, solvents, chlorine and ozone, bacteria.

    Filter materials and their properties:

    Birm: decreases and/or eliminates high iron and manganese values by oxidation.

    Zeolith: decomposes inorganic contamination (dissolving rate of strontium or caesium amounts to 99.9%) furthermore it cleans the water from heavy metals, ammoniac and nitrates.

    Active carbon: removal of odours and tastes (e.g. chlorine, ozone, humic matters) as well as herbicides, fungicides and drug residues etc.

    In this way the water is cleaned by the double removal of dirt, odours, iron admixtures and dioxins.

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 9 -

    FUNCTION/STRUCTURE

    As the name says, MWP is a highly effi cient micro purifi cation plant which, due to its high-precision & patented dosing of precipitati-on agents is largely superior to the standard communal treatment plants.

    Chamber 1

    Water is injected into the mixing tube. The “Wave-Pump” auto-matically doses the precipitation agent “PAC” into the water to be cleaned.

    The “precipitation” agents cause the following:

    • Emulation of all suspended turbidity ≥ 0.1 µm• Results in enhanced and faster elimination of turbidity• Signifi cantly improves water quality• Reduces sedimentation times• Increases service life of the downstream fi lters

    After the “precipitation agent” has reacted with the water (In total approx. 60 – 90 sec.) and chamber 1 is fi lled, the water fl ows into chamber 2 via an overfl ow tube after being pre-fi ltered through a 40 µm sponge fi lter.

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 10 -

    FUNCTION/STRUCTURE

    Chamber 2

    In this chamber the water continues to react with the “precipitation agent”.

    The second sponge fi lter – pore size 40 µm – fi lters the water again.The sponge fi lter should be cleaned at least once a day with clean water. Idealy also fl ush the chambers (at least once a month).

    Chamber 3

    The fi ltered water from chamber 2 is collected in chamber 3. Only after opening the dispense valve will the water be treated to beco-me drinking water and can be distributed.

    Once the water reaches the maximum level of chamber 3, then the supply pump and thereby also the dosing of the “precipitation agent” is stopped via a fl oat switch.

    Only when the minimum level is reached both systems are activa-ted again.

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 11 -

    FUNCTION/STRUCTURE

    UV-Lamp

    The water treated in chamber 3 is conducted through the UV-irradi-ation. Here 99.95% of all germs are deactivated. After exiting from the UV-Lamp the water is again fi ltered by a special fi lter.

    P-C-W Filter

    This fi lter cannot contaminate due to its design and is therefore installed downstream as a fi ne and safety fi lter. Possible germs are retained again in this fi lter and are deactivated through the oligo-dynamic eff ect. This fi lter additionally retains a large part of fungi-cides, pesticides, hormones or residues of drugs by adsorption. The downstream piping remains germ-free.

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 12 -

    COMMISSIONING

    • remove top cover

    • open front cover• raise wave-pump unit

    • place fl occulant• insert sponge fi lters

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 13 -

    COMMISSIONING

    • place pump in water source and plug in power cable

    • connect water-tap• if neccessary equip emergency • generator• plug in power cable to MWP

    You can fi nd more detailed instructions for the implementing of the Micro-Water-Plant in our instructions video at:

    www.micro-water-plant.com

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 14 -

    LABORATORY VALUES: BEFORE TREATMENT

    TEST REPORT 63120 - 165987Order 63120Analysis No. 165987 raw waterSample receipt 12.03.2014Sample collection 11.03.2014 08:55Sample collected from Agrolab Raimund SchimitzeCustomer sample identification RS 76Sampling point Jagst water after sewage plant BEFORE treatment by MWP

    TrinkwV: permissible maximum value / required range of the Drinking Water Ordinance of 21 May 2001 - current statusDIN 50930: required range of DIN 50930 „Corrosion behaviour of metallic materials to water“.

    Agrolab Stuttgart Cornelia Haubrich, Tel. +49 711/92556-47customer support Start of tests: 12.03.2014 End of tests: 15.03.2014 The test results refer exclusively to the test objects. In the case of samples of unknown origin, a plausibility check is only possible to a limited extent. Reproduction of extracts of the report without our written consent is not permitted.

    unit result Best-Gr. limit methodSensory testsColoring (on site) colorless EN ISO 7887Smell (on site) none DEV B1/2Turbidity (on site) faintly clouded DIN 38404-C2-1On-site inspectionsWater temperature (on site) °C 11,3 DIN 38404-C4Conductivity at 25°C µS/cm 603 1 EN 27888 (C8)Microbiological testsEnterococci CFU/100ml 71 0 EN ISO 7899-2E. coli CFU/100ml 2400 0 EN ISO 9308-1Coliform germs CFU/100ml 2400 0 EN ISO 9308-1Number of colonies at 20°C CFU/1ml 960 0 TrinkwV 2001 (2011) Anl. 5 l d) bb)

    Number of colonies at 36°C CFU/1ml 120 0 TrinkwV 2001 (2011) Anl. 5 l d) bb)

    Lab test before water treatment through Micro-Water-Plant.

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 15 -

    LABORATORY VALUES: AFTER TREATMENT

    TEST REPORT 67417 - 188833Order 67417Analysis No. 188833 raw waterSample receipt 27.05.2014Sample collection 25.05.2014 15:30Sample collected from principalCustomer sample identification by finished productSampling point by finished product

    Indicator parameters of the appendix 3 TrinkwV / chemical-technical and hygienic parameters

    1) for installations with less than 10 m³ per day (small installations for individual supply), a limit value of 1000 CFU/ml applies.

    TrinkwV: permissible maximum value / required range of the Drinking Water Ordinance of 21 May 2001 - current statusDIN 50930: required range of DIN 50930 „Corrosion behaviour of metallic materials to water“.

    TrinkwV: Ordinance on the quality of water intended for human consumption (TrinkwV 2001, last amended by Art. 1 V.v. 03.05.2011)

    Agrolab Stuttgart Cornelia Haubrich, Tel. +49 711/92556-47customer support Start of tests: 27.05.2014 End of tests: 29.05.2014 The test results refer exclusively to the test objects. In the case of samples of unknown origin, a plausibility check is only possible to a limited extent. Reproduction of extracts of the report without our written consent is not permitted.

    1)

    unit result Best-Gr. limit methodSensory testsColoring (on site) colorless EN ISO 7887Turbidity (on site) clear DIN 38404-2-1 (C 2-1)On-site inspectionsWater temperature (on site) °C 16,4 DIN 38404-4 (C 4)Microbiological testsEnterococci CFU/100ml 0 0 0 EN ISO 7899-2E. coli CFU/100ml 0 0 0 EN ISO 9308-1Coliform germs CFU/100ml 0 0 0 EN ISO 9308-1Number of colonies at 20°C CFU/1ml 0 0 100 TrinkwV 2001 (2011) Anl. 5 l d) bb)

    Number of colonies at 36°C CFU/1ml 0 0 100 TrinkwV 2001 (2011) Anl. 5 l d) bb)

    Lab test after water treatment through Micro-Water-Plant.

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 16 -

    DELIVERY RATE

    runtime 10 hrs. per day = 365 days x 10 = 3650 hours per year

    output per hour ca. 750-900 l = per day x 10 hours = 7500 liter per day x 365 days

    = min. 2.737.500 liter per year

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 17 -

    M.W.P. MISSION IN GHANA

    M.W.P. in Ghana in the orphanage of the foundation Home for Hope - in the small village Gomoa Tarkwa in the south of Ghana.

    The Micro Water Plant was unpacked on site and put into ope-ration within 20 minutes by two young women with very limited technical experience.

    This simple commissioning on site clearly shows that the Micro Water Plant exactly meets the requirements for which it was developed and produced.

    The construction, commissioning and production of drinking water can be carried out at any time, even by non-professionals.

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 18 -

    M.W.P. MISSION IN PERU

    M.W.P. in operation in Peru in Pasco at an altitude of 4300 m abo-ve sea level. The simple installation and commissioning was carried out by our local partner Unus on site.

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 19 -

    RUNNING COSTS

    M.W.P. running costs per liter / year (available power source)

    usage per hour per day per yearpower consumption 400W 1Kwh = 0,2765€ = 0,1106€ x 10 = 1,106€ x 365 = 403,69€

    Flocculant 1l = 6,25€ 30ml / hr. = 0,1875€ x 10 = 1,875€ x 365 = 684,38€

    UV-Lamp: 8000 hrs., 135€ 0,016875€ x 10 = 0,16875€ x 365 = 61,59€

    as required

    fi lter material replacement 30,00€

    membrane replacement 29,75€

    fi lter mats 26,50€

    write-down over 7 years; buy price 1714,29€ / year*

    total costs incl. write-down: 2863,95€ / year

    costs per liter without write-down 0,000419€ / liter

    including write-down 0,001046€ / liter

    *example pricing

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 20 -

    RUNNING COSTS

    M.W.P. running costs per liter / year (emergency generator)

    usage per hour per day per yearfuel costs 1,65€ / liter 1,1l / hr. = 1,815€ x 10 = 18,15€ x 365 = 6624,75€

    Flocculant 1l = 6,25€ 30ml / hr. = 0,1875€ x 10 = 1,875€ x 365 = 684,38€

    UV-Lamp: 8000 hrs., 135€ 0,016875€ x 10 = 0,16875€ x 365 = 61,59€

    as required

    fi lter material replacement 30,00€

    membrane replacement 29,75€

    fi lter mats 26,50€

    write-down over 7 years; buy price 1714,29€ / year*

    total costs incl. write-down:9085,01€ / year

    costs per liter without write-down 0,00269€ / liter

    including write-down 0,00332€ / liter

  • www.micro-water-plant.com Micro Water Plant UG (haftungsbeschränkt)Härtsfeldstraße 103, 73466 Lauchheim, Germany

    - 21 -

    CONTACT

    Information Disclaimer

    Micro-Water-Plant assumes no responsibility for the topicality, correctness, price, completeness or quality of the information and data provided. Liability claims against the author are exclu-ded. The information does not constitute legal assurances.

    Micro-Water-Plant is not liable for direct or indirectDamage caused by the use of the information orData is created.

    © Copyright by Micro-Water-Plant

    Document as of: 06.06.2020

    Micro-Water-Plant UG (haftungsbeschränkt)

    Härtsfeldstraße 10373466 Lauchheim/Germany

    Tel. +49(0)7363-919591

    email: [email protected]

    Current prices and delivery conditions can be found at www.micro-water-plant.com and in our General Terms and Conditions.