Event Log Codes for Cpqcisse

Embed Size (px)

Citation preview

CpqCisse Event Log Codes The purpose of this document is to list the Event IDs of every possible event logged by the device driver cpqcisse.sys to the Windows NT event log. Cpqcisse.sys works in conjunction with cpqcissm.sys which is the miniport driver for the array controller. Cpqcisse.sys supports the below storage products: 1Smart Array 5300 Controller 2Smart Array 5i 3Smart Array 532 Controller 4Smart Array 5312 Controller 5Smart Array 6i 6Smart Array 641 Controller 7Smart Array 642 Controller 8Smart Array 6400 Controller 9Smart Array 6400 U320 EM Controller 10Smart Array Cluster Storage Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is provided as is without warranty of any kind and is subject to change without notice. The warranties for HP products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty.Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: 24577 Information No Events reported for the [Array controller location] 24578 Information The Event Notifier has been disabled for the [Array controller location] 24579 Information Event Queue Overflow on the [Array controller location]. At least one event notification has been lost. This controller will only queue up to 100 events. 24580 Information Physical Drive [Action]: SCSI Port [Number], ID [Number], of [Array controller location]. 24581 Information Physical Drive [Action]: SCSI ID [Number] of [Array controller location]. 24582 Information

Event ID: Type: Message: Event ID: Type: Message: Event ID: Type:

Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message:

One of the Redundant Power Supply is [Action]: on Chassis Name[Location] connected to SCSI Port [Number], of [Array controller location]. 24583 Information External Fan [Action]: SCSI Port [Number], ID [Number], of [Array controller location]. 24584 Information UPS [Action]: SCSI Port [Number], ID [Number], of [Array controller location]. 24585 Information [Array controller location] has detected more than 1 cable with active drives attached. See next event (UP ARROW) for Controller message. 24586 Warning Too Many runtime ECC errors on [Array controller location]. Controller restarted without SIMM. See next event (UP ARROW) for Controller message. 24587 Warning One of the Fan in [Location]ternal storage device with Chassis Name[Chassis Serial Number] connected to Port [Number] of [Array controller location], has reported a fault. 24588 Warning Sensor [Number] of [Location]ternal storage device on [Location] Port [Number] of [Array controller location], is reporting the internal temperature has exceed the preset limit. The controller may attempt to shut down power to the storage device and/or spin down the installed disk drives.

Event ID: Type: Message:

Event ID: Type: Message:

Event ID: Type: Message:

Event ID: Type: Message:

24589 Warning Sensor [Number] of [Location]ternal storage device on [Location] Port [Number] of [Array controller location], is reporting the temperature is nearing the preset temperature limit. The controller may enact precautionary measures to prevent data loss should the temperature reach the operating limit. 24590 Information Sensor [Number] of [Location]ternal storage device on [Location] Port [Number] of [Array controller location], is reporting the correction of a previously existing temperature condition. All of the temperature sensors in the [Location]ternal storage device are now reporting acceptable temperature levels. 24591 Warning One of the Redundant Power supply of External Storage device with Chassis

Event ID: Type: Message:

Event ID: Type: Message:

Name [Chassis Serial Number] connected to Port [Number] of [Array controller location] has reported a fault. Event ID: Type: Message: 24592 Information One of the Redundant Power supply of External Storage device with Chassis Name [Chassis Serial number] connected to Port [Number] of [Array controller location] is operational. 24593 Warning The chassis door of External Storage System on Port [Number] of [Array controller location] is open. The controller may attempt to shut down the power to the storage device and/or spin down the installed disk drives. 24594 Warning Power supply [Number] of [Location]ternal Storage Device with Chassis Name [Chassis Serial Number] connected to Port [Number] of [Array controller location], has reported an AC Power failure. 24595 Warning Power supply [Number] of [Location]ternal storage Device with Chassis Name[Chassis Serial Number] connected to Port [Number] of [Array controller location], has reported a Battery Low condition. 24596 Error Physical Drive [Number] of [Array controller location], has failed. Failure Code: [Controller specific failure code].

Event ID: Type: Message:

Event ID: Type: Message:

Event ID: Type: Message:

Event ID: Type: Message:

Event ID: Type: Message:

24597 Error Physical Drive on SCSI Port [Number], ID [Number] of [Array controller location], has failed. Failure Code: [Controller specific failure code]. 24598 Information Logical Drive [Number] of [Array controller location] has changed from status code [Number] to status code [Number]. Status Codes: 0 = OK 1 = FAILED 2 = NOT CONFIGURED 3 = INTERIM RECOVERY MODE 4 = READY FOR RECOVERY 5 = RECOVERING 6 = WRONG PHYSICAL DRIVE REPLACED 7 = PHYSICAL DRIVE NOT PROPERLY CONNECTED 8 = HARDWARE IS OVERHEATING 9 = HARDWARE HAS OVERHEATED

Event ID: Type: Message:

10 = EXPANDING 11 = NOT YET AVAILABLE 12 = QUEUED FOR EXPANSION 13 = UNKNOWN Event ID: Type: Message: 24599 Warning Logical Drive [Number] of [Array controller location] has changed from status code [Number] to status code [Number]. Status Codes: 0 = OK 1 = FAILED 2 = NOT CONFIGURED 3 = INTERIM RECOVERY MODE 4 = READY FOR RECOVERY 5 = RECOVERING 6 = WRONG PHYSICAL DRIVE REPLACED 7 = PHYSICAL DRIVE NOT PROPERLY CONNECTED 8 = HARDWARE IS OVERHEATING 9 = HARDWARE HAS OVERHEATED 10 = EXPANDING 11 = NOT YET AVAILABLE 12 = QUEUED FOR EXPANSION 13 = UNKNOWN 24600 Error Logical Drive [Number] of [Array controller location] has changed from status code [Number] to status code [Number]. Status Codes: 0 = OK 1 = FAILED 2 = NOT CONFIGURED 3 = INTERIM RECOVERY MODE 4 = READY FOR RECOVERY 5 = RECOVERING 6 = WRONG PHYSICAL DRIVE REPLACED 7 = PHYSICAL DRIVE NOT PROPERLY CONNECTED 8 = HARDWARE IS OVERHEATING 9 = HARDWARE HAS OVERHEATED 10 = EXPANDING 11 = NOT YET AVAILABLE 12 = QUEUED FOR EXPANSION 13 = UNKNOWN 24601 Information Logical drive [Number] on Chassis name [Chassis Serial Number] configured on [Array controller location], is in a FAILED state but has had one or more drive replacements and is ready to go to OK. However, this will not happen until the logical drive is re-enabled. Please re-enable the logical drive either via HP ACU (Array Configuration Utility) or by rebooting the system. 24602 Warning Recovery of logical drive [Number] configured on [Array controller location], was

Event ID: Type: Message:

Event ID: Type: Message:

Event ID: Type: Message:

aborted while rebuilding physical drive [Number] due to an unrecoverable read error. The physical drive reporting the error is [Number]. Event ID: Type: Message: 24603 Warning Recovery of logical drive [Number] configured on [Array controller location], was aborted while rebuilding physical drive with SCSI ID [Number] on SCSI Port [Number] due to an unrecoverable read error. The physical drive reporting the error is SCSI ID [Number] on SCSI Port [Number]. 24604 Warning Recovery of logical drive [Number] configured on [Array controller location], was aborted while rebuilding physical drive [Number] due to an unrecoverable write error. The physical drive reporting the error is [Number]. 24605 Warning Recovery of logical drive [Number] configured on [Array controller location], was aborted while rebuilding physical drive with SCSI ID [Number] on SCSI Port [Number] due to an unrecoverable write error. The physical drive reporting the error is SCSI ID [Number] on SCSI Port [Number]. 24606 Error Logical drive [Number] configured on [Array controller location], has returned a fatal error on a read/write request on the volume. Logical block address [Number], block count [Number], command [Number], drive bus [Number] and Drive Id [Number].

Event ID: Type: Message:

Event ID: Type: Message:

Event ID: Type: Message:

Event ID: Type: Message:

24607 Warning The event notification information received from [Array controller location] was of unknown or unrecognized class. Controller message : [Text string]. 24608 Information External Array Controller attached to [Array controller location] is active. 24609 Error External Array Controller attached to [Array controller location] is redundant. 24610 Error External Array Controller attached to [Array controller location] is no longer redundant because an Array Controller is missing. 24611 Error External Array Controller attached to [Array controller location] is no longer redundant because the Array Controllers are different models.

Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message:

The standby Array Controller has been marked as failed. Event ID: Type: Message: Event ID: Type: Message: 24612 Error External Array Controller attached to [Array controller location] is no longer redundant because the inter-controller link has failed. 24613 Error External Array Controller attached to [Array controller location] is no longer redundant because the Array Controllers have different levels of firmware. The standby Array Controller has been marked as failed. 24614 Error External Array Controller attached to [Array controller location] is no longer redundant because both Array Controllers cannot see all the physical drives. The standby Array Controller has been marked as failed. 24615 Error External Array Controller attached to [Array controller location] is no longer redundant because one or more drives has been determined not to be able to support redundant controller operation. The standby Array Controller has been marked as failed.

Event ID: Type: Message:

Event ID: Type: Message:

Event ID: Type: Message: Event ID: Type: Message:

24616 Information Redundant Controller [Hot Plug Action] on Port [Number], ID [Number], of [Array controller location]. 24617 Information One of the Fan in [Location]ternal Storage device with Chassis Name [Chassis Serial Number] connected to Port [Number] of [Array controller location], is reporting a degraded condition. 24618 Information Fan [Number] of [Location]ternal storage device with Chassis Name [Chassis Serial Number] connected to Port [Number] of [Array controller location], is operational. 24619 Information The chassis door of External Storage device [Number] of [Array controller location], is closed. 24623 Information Tape Drive [Action] : SCSI Port [Number], ID [Number], of [Array controller location]. 24624

Event ID: Type: Message:

Event ID: Type: Message: Event ID: Type: Message: Event ID:

Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message:

Information Tape Drive [Action] : SCSI ID [Number], of [Array controller location]. 24625 Information Physical Drive [Action], From Chassis Name [Chassis Serial Number], Bay [Location] of [Array controller location]. 24626 Information Tape Drive [Action], From Chassis Name [Chassis Serial Number], Bay [Location] of [Array controller location]. 24627 Information Redundant Power Supply [Action], on Box [Number], Port [Number] and ID [Number] of [Array controller location]. 24628 (SA Cluster Storage) Information External Fan [Action], In Chassis Name [Chassis Serial Number] connected to Port [Number] and ID [Number] of [Array controller location] 24632 Information The External Storage System of [Array controller location], has reported that the Cache has been temporarily disabled. 24633 Information The External Storage System of [Array controller location], has reported that the Cache has been re-enabled. 24634 Information The External Storage System of [Array controller location], has reported that the Cache batteries have been removed. 24638 Warning Redundant Power supply [Number] of External Storage device on Box [Number], Port [Number] of [Array controller location] has reported a fault. 24639 Information Redundant Power supply [Number] of External Storage device on Box [Number], Port [Number] of [Array controller location] is operational. 24640 Information UPS [Action]: Box [Number], Port [Number], ID [Number] of [Array controller location].

Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message:

Event ID: Type: Message:

24641 Warning The chassis door of External Storage System on Box [Number], Port [Number] of [Array controller location] is open. The controller may attempt to shut down the power to the storage device and/or spin down the installed disk drives. 24644 Error Physical Drive in Box [Number], Bay [Number] of [Array controller location] has failed. Failure Code: [Number]

Event ID: Type: Message:

Event ID: Type: Message:

24645 Warning Recovery of logical drive [Number] in Chassis Name [Chassis Serial Number], configured on [Array controller location], was aborted while rebuilding physical drive in Box [Number], Bay [Number] due to an unrecoverable read error. The physical drive reporting the error is in Box [Number], Bay [Number]. 24646 Warning Recovery of logical drive [Number] in Chassis Name [Chassis Serial Number], configured on [Array controller location], was aborted while rebuilding physical drive in Box [Number], Bay [Number] due to an unrecoverable write error. The physical drive reporting the error is in Box [Number], Bay [Number]. 24647 Information External Array Controller attached to [Array controller location] is active. 24648 Information External Array Controller attached to [Array controller location] is redundant. 24649 Error External Array Controller attached to [Array controller location] is no longer redundant because an array controller is missing. 24650 Information SnapShot ID [Number] of Logical Drive [Number] on [Array controller location], has been created. 24651 Error SnapShot ID [Number] of Logical Drive [Number] on [Array controller location], failed and has been deleted. 24652 Information SnapShot ID [Number] of Logical Drive [Number] on [Array controller location],

Event ID: Type: Message:

Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message:

has been restored. Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: 24653 Information SnapShot ID [Number] of Logical Drive [Number] on [Array controller location], has been detached. 24654 Information SnapShot ID [Number] of Logical Drive [Number] on [Array controller location], has been deleted. 24655 Error Restore operation of SnapShot ID [Number] of Logical Drive [Number] on [Array controller location], is failed, possible data corruption. 24656 Warning SnapShot ID [Number] of Logical Drive [Number] on [Array controller location], has been disabled. 24657 Information Performing a recovery for a restore operation on SnapShot [Number] for Logical Drive [Number] on [Array controller location]. 24658 Information Restore operation started on SnapShot ID [Number] for Logical Drive [Number] on [Array controller location]. 24659 Information SnapShot ID [Number] of Logical Drive [Number] on the external controller attached to [Array controller location], has been created. 24660 Error SnapShot ID [Number] of Logical Drive [Number] on the external controller attached to [Array controller location] failed and has been deleted. 24661 Information SnapShot ID [Number] of Logical Drive [Number] on the external controller attached to [Array controller location], has been restored. 24662 Information SnapShot ID [Number] of Logical Drive [Number] on the external controller attached to [Array controller location], has been detached. 24663 Information SnapShot ID [Number] of Logical Drive [Number] on the external controller attached to [Array controller location], has been deleted.

Event ID: Type: Message:

24664 Error Restore operation of SnapShot ID [Number] of Logical Drive [Number] on the external controller attached to [Array controller location] is failed, possible data corruption. 24665 Warning SnapShot ID [Number] of Logical Drive [Number] on [Array controller location], has been disabled. 24666 Information Performing a recovery for a restore operation on SnapShot [Number] for Logical Drive [Number] on the external controller attached to [Array controller location]. 24667 Information Restore operation started on SnapShot ID [Number] of Logical Drive [Number] on the external controller attached to [Array controller location]. 24668 Information SnapShot Resource Volume of Logical Drive [Number] on [Array controller location], is okay. 24669 Warning Resource Volume of Logical Drive [Number] on [Array controller location], is approaching its limit. 24670 Error SnapShot Resource Volume of Logical Drive [Number] on [Array controller location], has failed. 24671 Information SnapShot Resource Volume of Logical Drive [Number] on [Array controller location], has been deleted. 24672 Error SnapShot Resource Volume of Logical Drive [Number] on [Array controller location], has reached its limit. 24673 Information SnapShot Resource Volume of Logical Drive [Number] on the external controller attached to [Array controller location], is okay. 24674 Warning SnapShot Resource Volume of Logical Drive [Number] on the external controller attached to [Array controller location], is approaching its limit.

Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message:

Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message:

24675 Error SnapShot Resource Volume of Logical Drive [Number] on the external controller attached to [Array controller location], has failed. 24676 Information SnapShot Resource Volume of Logical Drive [Number] on the external controller attached to [Array controller location], has been deleted. 24677 Error SnapShot Resource Volume of Logical Drive [Number] on the external controller attached to [Array controller location], has reached its limit. 24678 Warning The License Key on [Array controller location] is nearing its expiration date. License Key will expire in [Number] day(s). See next event (UP ARROW) for License Key 24679 Warning The License Key: [Continued text string]. 24680 Error The License Key on [Array controller location] has expired See next event (UP ARROW) for License Key 24683 Warning SCSI bus fault occurred on Storage Box [Number], Port [Number] of [Array controller location], which may result in a "downshift" in transfer rate for one or more hard drives on the bus. 24684 Information Error log update occurred for Physical Drive [Number] of [Array controller location]. 24685 Information The Event Notification driver Cpqcisse.sys of [Array controller location] has started. 24686 Error The Event Notification driver Cpqcisse.sys of [Array controller location] has failed to start. 24687 Information The [Array controller location] has reported that its Cache has been temporarily disabled.

Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message:

Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message:

Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message: Event ID: Type: Message:

24688 Information The [Array controller location] has reported that its Cache has been re-enabled. 24689 Information The [Array controller location] has reported that its Cache batteries have been removed. 24690 Information Consistency initialization pass completed for logical drive [Number] of [Array controller location]. 24691 Information External redundant controller [Number], attached to the [Array controller location] has been [Action]. 24692 Information Firmware update needed for Physical Drive on Procuct ID [ID] of Array Controller [Location]. Recommended minimum Version of [Version Number]. 24693 Information The External Storage System of Array Controller [Location] has reported that the DIMM (cache board) battery is failed/bad. 24694 Information The External Storage System of Array Controller [Location] has reported that the On-board battery is failed/bad. 24695 Information The External Storage System of Array Controller [Location] has reported that both DIMM(cache board) and On-board batteries are failed/bad. 24696 Information The External Storage System of Array Controller [Location] has reported that location of failed battery is unknown. 24697 Error Logical drive [Number], on Chassis Name [Name], configured on Array Controller [Location], returned a fatal error, rebuild encounted media error(BAD BLOCK) on the volume, but the rebuilding will continue for completion.Logical block address [Number], block count [Number], command [Number], drive bus [Number] and Drive Id [Number]. 24698 Error Surface Scan encounted media error for logical drive [Number] of Array

Event ID: Type: Message:

Controller[Location] Event ID: Type: Message: 25001 Information Back (DOWN ARROW) message continued = [Text String]" Forward (UP ARROW) 25002 Information Back (DOWN ARROW) message continued = [Text String]" END 25003 Warning The event notification information received from [Array controller location] was of unknown or unrecognized class. See next event (UP ARROW) for Controller message. 25004 Warning Rebuild was completed on Logical Drive [LD Number], Configured on Array controller [AC Number], HBA [Slot Number], Chassis:[Name] despite uncorrectable media errors. Fault-tolerance may have been restored by the rebuild. But bad spot(s) that were encountered will not be readable. Backup and restore is recommended 25005 Information Consistency Initialization pass completed for Logical Drive [LD Number] Configured on Array Controller [AC Number],HBA [Slot No], Chassis:[Name]. 25006 Error Unrecoverable Read error occurred while rebuilding the logical drive [LD Number] configured on Array controller [AC Number], HBA [Slot Number], Chassis: [Name],but rebuild is continuing so that the volume can regain fault tolerance. Unrecoverable Media defects are somewhere in Logical Block Address [LBA1] and Logical Block Address [LBA2].

Event ID: Type: Message:

Event ID: Type: Message:

Event ID: Type: Message:

Event ID: Type: Message: Event ID: Type: Message: