actrol.com.au

global brands - local service

CaberoEvaporators

April 2015

2.global brands - local service

CaberoAdvantages

The Cabero Advantage

The German designed evaporator range from Cabero incorporates innovative design features that offer customers both good performance and longevity.

The professional inline tube pattern reduces dehumidification enhancing the shelf life of perishable foods such as meat, fruit and vegetables.

Blue fin coating and powder coated high grade aluminium cases provide corrosion protection and improved hygiene.

Standard design features make Cabero a great choice for coolrooms and freezers in applications such as convenience stores, supermarkets, pubs and clubs, butchers, groceries, deli’s, food processors, distribution centres, ice cream stores and any other walk in application.

Cabero evaporators are a key component for an efficient refrigeration system.Stable temperature and humidity ensures that sensitive products like vegetables, meat, cheese or fish will maintain optimum weight, quality and storage life.

Universal Features of Cabero

• Blue fins provide corrosion protection• Fans and defrost heaters are fully wired to junction box/s

(IP54) with cable glands• High efficiency external rotor fan/s (IP44)• Air bypass panel increases efficiency by eliminating air

leakage around coil• Separate fan compartments in all multi fan models• Reduced dehumidification (moisture removal) and ice

formation is achieved through the inline tube configuration• Unit casings are manufactured from high grade aluminium

and powder coated white for greater corrosion and hygiene protection

• Fold down drip trays make maintenance quick and easy• Drip tray is painted internally for easy cleaning and is

thermally decoupled and detachable from the heat exchanger casing for increased defrosting efficiency

3.global brands - local service

Technical Features of Cabero

• Specially designed 12mm smooth bore thick walled copper tubes are less sensitive to pressure drop changes

• Multi refrigerant venturi type distributor suits all commonly used refrigerants

• Fin spacing of 4mm and 6.8mm• Inline tube design of 35 x 35mm• Refrigerant line connections are on the left hand

end• Flush mounting to ceiling standard on all models• Low noise levels due to fans design and increased

depth between fan and coil face• Pressure tested according to the PED 97/23/EC

and EN327:2000 at 27.5 bar• Powder coated aluminium in RAL 9010

Advantages of Parallel Inline Pipe

• Reduced moisture removal• Reduced air side pressure drop• Reduced defrost frequency

Staggered Parallel

Others Cabero

Air

Air

Air

Air

CaberoAdvantages

4.global brands - local service

LPC SeriesCabero

Standard Features

• Low profile suits small rooms and reach in cabinets

• Professional in-line tube configuration

• Forced draught provides even air distribution

• Low energy fan/s• Powder coated smooth

aluminium case • Separate fan compartments• Venturi distributor for multiple

refrigerants • Stainless steel fixings• 12mm smooth bore copper

tubing • Flush mount ceiling brackets• Fan/s pre-wired to IP54 junction

box • Fold down drip tray with central

drain conn.• Fins protected with Blue-Fin

coating • Air bypass sheet with special

drainage system

LPC series evaporators are suited for use in smaller coolrooms and freezers, rooms with low ceiling heights or refrigerated cabinets.

The forced draft air flow and reduced cabinet height of the LPC series allows the room loading space to be maximised.LPC evaporators are commonly used in multi door reach in cool and freezer rooms in convenience stores where the air flow is often directed towards the rear of the room.

The combination of blue fin coating and 12mm smooth bore thick walled copper tubes protect the heat transfer surface from food acids to maintain performance and the 300mm internal rotor forced draft fan motors are energy efficient, quiet and move generous air volumes to reach all corners of the refrigerated space.

Installing an LPC is made easy with fully wired fans and defrost heaters. The side panels are removable providing clear access to all internal components and for easier fitting of the TX valve and the multi refrigerant distributors require no adjustment. The internally painted drip tray folds down quickly and easily for cleaning of the drip tray and accessing the drip tray defrost heater/s.

LPC evaporators are a good choice for all small rooms and cabinets where maximising stock capacity and even temperature of product is important.

5.global brands - local service

Cabero CH series evaporators are typically used in walk-in cool and freezer rooms with ceiling heights of 2 metres or more. CH evaporators are commonly used in in fast food outlets, butchers shops, fruit and vegetable shops and general purpose coolrooms and freezers.

Plentiful air movement is provided by the quiet and efficient 300, 350 and 500mm external rotor fan motors to reach all the products in the refrigerated space.

The design combination of induced draft air flow, larger distance between the fan and coil face and the air bypass panel provides very good air throw to reach all corners of the room.

CH evaporators are fully wired to reduce installation time and the easy to fold down drip tray allows for quick and easy internal cleaning and on the low temperature models for maintenance of the drip tray defrost heater/s.

All Cabero CH evaporators use blue fin coating and 12mm smooth bore thick walled copper tubes to extend the efficient life of the evaporator making the CH series a good choice for clients wanting to maximise product quality and storage life.

Standard Features

• Walk-In profile suits cool and freezer rooms

• Powder coated smooth aluminium case

• Low energy fan/s• Venturi distributor for multiple

refrigerants • Separate fan compartments • 12mm smooth bore copper

tubing • Stainless steel fixings • Fins protected with Blue-Fin

coating • Flush mount ceiling brackets• Fan/s pre-wired to IP54 junction

box • Air bypass sheet with special

drainage system • Professional in-line tube

configuration • Fold down drip tray with central

drain connection

Cabero

CH Series

6.global brands - local service

Forced Draft Evaporator

Medium Temperature Application

Cat. No. Part No.

Capacity @ -4˚C SST & 6 KTD : Watts Air

Flow m3/h

Air Throw

m

No. & Dia. of Fans

Fan MotorsConnect. inches

Overall Dim: mm

R404A R507

R134a R22Total Watts

Total Amps

Heat/24 Hrs Total

WattsLiq. Suct. Length Depth Height

300mm Diameter Fan Models - 4mm Fin Spacing (6 FPI)LPC4A1/30.1* 1155 1051 1097 1350

7

1 x 300 85 0.38 2040

1/2

815

670 380

291212 LPC4B1/30.1* 1617 1471 1536 1210

291214 LPC4C1/30.1* 1991 1812 1891 11206

5/8

3/4LPC4D1/30.1 2178 1982 2069 1060

291218 LPC4E1/30.1 2442 2222 2320 1000 5

291220 LPC4B2/30.1 3289 2993 3125 2420 7

2 x 300 170 0.76 4080 7/8 1365291222 LPC4C2/30.1 4048 3684 3846 2240

6LPC4D2/30.1 4510 4104 4285 2120

291226 LPC4E2/30.1 4961 4515 4713 2000 5

291228 LPC4C3/30.1 6061 5516 5758 33606

3 x 300 255 1.14 6120

1 1/8

1915LPC4D3/30.1 6930 6306 6584 3180

LPC4E3/30.1 7469 6797 7096 3000 5

LPC4C4/30.1 8140 7407 7733 44806

4 x 300 340 1.52 8160 2465291238 LPC4D4/30.1 9262 8428 8799 4240

LPC4E4/30.1 10032 9129 9530 4000 5

Capacity Correction FactorsSuction Temp. ˚C -10 -8 -6 -4 -2 0 2 4 6 9 12 15

Capacity Multiplier

R404A R22 R507

0.99 0.99 0.99 1.00 1.00 1.02 1.02 1.03 1.05 1.06 1.12 1.14

R134a 0.87 0.91 0.95 1.00 1.00 1.01 1.01 1.02 1.04 1.07 1.12 1.14

X Capacity for suction temperatures other than -4˚C can be calculated from the correction table

X * Internally equalised TX Valve. All other models require externally equalised TX Valves

Selection Data

LPC Series

7.global brands - local service

Forced Draught Evaporator

Low Temperature Application

Cat. No. Part No.

Capacity @ -24˚C SST & 6

KTD : Watts Air Flow m3/h

Air Throw

m

No. & Dia. of Fans

Fan MotorsDefrost Heaters

240 VoltsConnect. inches

Overall Dim: mm

R404A R507

R22Total Watts

Total Amps

Heat/ 24 Hrs Total Watts

Coil No. & Watts

Drip Tray No. & Watts

Liq. Suct. Length Depth Height

300mm Diameter Fan Models - 4mm Fin Spacing (6 FPI)LPC4A1/30E.1* 880 836 1350

7

1 x 300 85 0.38 2040

2 x 600

1 x 600

1/2

815

670 380

291312 LPC4B1/30E.1* 1190 1131 1210

291314 LPC4C1/30E.1* 1370 1302 11206

5/8

3/4LPC4D1/30E.1 1580 1501 10603 x 600

291318 LPC4E1/30E.1 1730 1644 1000 5

291320 LPC4B2/30E.1 2350 2233 2420 7

2 x 300 170 0.76 4080

2 x 1100

1 x 1100 7/8 1365291322 LPC4C2/30E.1 2800 2660 2240

6LPC4D2/30E.1 3160 3002 2120

3 x 1100291326 LPC4E2/30E.1 3470 3297 2000 5

291328 LPC4C3/30E.1 4280 4066 33606 3 x

300 255 1.14 6120

2 x 1600

1 x 1600

1 1/8

1915LPC4D3/30E.1 4870 4627 31803 x 1600

291332 LPC4E3/30E.1 5230 4969 3000 5

LPC4C4/30E.1 5650 5368 44806 4 x

300 340 1.52 8160

2 x 2100

1 x 2100 2465LPC4D4/30E.1 6290 5976 42403 x 2100

291338 LPC4E4/30E.1 6980 6631 4000 5

Capacity Correction FactorsSuction Temp. ˚C -36 -33 -30 -27 -24 -21 -18 -15 -12

Capacity Multiplier

R404A, R507 0.77 0.83 0.89 0.94 1.00 1.06 1.12 1.19 1.25

R22 0.81 0.86 0.91 0.95 1.00 1.05 1.1 1.17 1.23

X Capacity for suction temperatures other than -24˚C can be calculated from the correction table.

X * Internally equalised TX Valve. All other models require externally equalised TX Valves

Selection Data

LPC E Series

8.global brands - local service

Induced Draft Evaporator

Medium Temperature Application

Cat. No. Part No.

Capacity @ -4˚C SST & 6 KTD : Watts Air

Flow m3/h

Air Throw

m

No. & Dia. of Fans

Fan MotorsConnect. inches

Overall Dim: mm

R404A R507

R134a R22Total Watts

Total Amps

Heat/24 Hrs Total

WattsLiq. Suct. Length Depth Height

300mm and 350mm Diameter Fan Models - 4mm Fin Spacing (6 FPI)291408 CH7B1/30-1* 1480 1347 1406 447

6 1 x 300 85 0.38 2040

1/2

1/2 850

560 470

291410 CH4B1/30-1 2120 1929 2014 1580

291412 CH4C1/30-1 2590 2357 2461 1540

291414 CH4B1/35-1 3060 2785 2907 2480

71 x 350 140 0.60 3360 5/8 1050

291416 CH4C1/35-1 3980 3622 3781 2390

291418 CH4B2/30-1 4240 3858 4028 3160 2 x 300 170 0.76 4080

3/4

1300

291420 CH4D1/35-1 4530 4122 4304 22406 1 x 350 140 0.60 3360 1050

CH4E1/35-1 4850 4414 4608 2110

291424 CH4C2/30-1 5170 4705 4912 3080 7 2 x 300 170 0.76 4080 1300

291426 CH4B2/35-1 6480 5897 6156 49809

2 x 350 280 1.20 6720 1700291428 CH4C2/35-1 7970 7253 7572 4760

7/8 291430 CH4D2/35-1 9000 8190 8550 4430

8

5/8 291432 CH4E2/35-1 9890 9000 9396 4260

1 1/8 291434 CH4C3/35-1 11910 10838 11315 6970 10

3 x 350 420 1.80 10080 2350291436 CH4D3/35-1 13850 12604 13158 6620

9291438 CH4E3/35-1 14940 13595 14193 6340

291440 CH4D4/35-1 18470 16808 17547 87804 x 350 560 2.40 13440 7/8 1 3/8 3000

291442 CH4E4/35-1 20800 18928 19760 8490

* 6.8mm Fin Spacing (3.7 FPI)

500mm Diameter Fan Models - 4mm Fin Spacing (6 FPI)CH4C1/50-1 11460 10429 10887 7320 26

1 x 500 750 1.30 18000 5/8 1 1/8

1420

670 750

291452 CH4D1/50-1 13740 12503 13053 7110 25

CH4E1/50-1 15190 13823 14431 6920 24

291456 CH4G1/50-1 17450 15880 16578 6510 22

7/8

1 3/8 291458 CH4C2/50-1 23220 21130 22059 14640 27

2 x 500 1500 2.60 36000 2500291460 CH4D2/50-1 27690 25198 26306 14220 26

1 5/8 291462 CH4E2/50-1 30720 27955 29184 13840 25

291464 CH4G2/50-1 35400 32214 33630 13020 23

291466 CH4D3/50-1 41490 37756 39416 21330 26

3 x 500 2250 3.90 54000 2 1/8 3580291468 CH4E3/50-1 46640 42442 44308 20760 251 1/8

291470 CH4G3/50-1 51680 47029 49096 19530 23

Capacity Correction FactorsSuction Temp. ˚C -10 -8 -6 -4 -2 0 2 4 6 9 12 15

Capacity Multiplier

R404A R22 R507

0.99 0.99 0.99 1.00 1.00 1.02 1.02 1.03 1.05 1.06 1.12 1.14

R134a 0.87 0.91 0.95 1.00 1.00 1.01 1.01 1.02 1.04 1.07 1.12 1.14

X Capacity for suction temperatures other than -4˚C can be calculated from the correction table.

X * Internally equalised TX Valve. All other models require externally equalised TX Valves

Selection Data

CH Series

9.global brands - local service

Selection Data

CH E Series

Induced Draught Evaporator

Low Temperature Application

Cat. No. Part No.

Capacity @ -24˚C SST & 6

KTD : Watts Air Flow m3/h

Air Throw

m

No. & Dia. of Fans

Fan MotorsDefrost Heaters

240 VoltConnect. inches

Overall Dim: mm

R404A R507

R22Total Watts

Total Amps

Heat/ 24 Hrs Total Watts

Coil No. & Watts

Drip Tray No. & Watts

Liq. Suct. Length Depth Height

300mm and 350mm Diameter Fan Models - 4mm Fin Spacing (6 FPI)291508 CH7B1/30E-1* 1170 1112 447

6 1 x 300 85 0.38 2040 2 x 450 1 x 450

1/2

1/2 850

560 470

291510 CH4B1/30E-1 1590 1511 1580

291512 CH4C1/30E-1 1820 1729 1540

291514 CH4B1/35E-1 2310 2195 2480

71 x 350 140 0.60 3360 2 x 650 1 x 650 5/8 1050

291516 CH4C1/35E-1 2950 2803 2390

291518 CH4B2/30E-1 3180 3021 3160 2 x 300 170 0.76 4080 2 x 850 1 x 850

3/4

1300

CH4D1/35E-1 3310 3145 22406 1 x 350 140 0.60 3360 4 x 650 1 x 650 1050

291522 CH4E1/35E-1 3450 3278 2110

291524 CH4C2/30E-1 3650 3468 3080 7 2 x 300 170 0.76 4080 2 x 850 1 x 850 1300

291526 CH4B2/35E-1 5040 4788 49809

2 x 350 280 1.20 6720

2 x 1200

1 x 1200 1700291528 CH4C2/35E-1 6100 5795 4760

7/8 291530 CH4D2/35E-1 6890 6546 4430

8 4 x 1200

5/8 291532 CH4E2/35E-1 7210 6850 4260

1 1/8 291534 CH4C3/35E-1 9080 8626 6970 10

3 x 350 420 1.80 10080

2 x 1750

1 x 1750 2350CH4D3/35E-1 10290 9775 6620

9

4 x 1750291538 CH4E3/35E-1 10790 10251 6340

291540 CH4D4/35E-1 13760 13072 87804 x 350 560 2.40 13440 4 x 2300 1 x 2300 7/8 1 3/8 3000

291542 CH4E4/35E-1 14900 14155 8490

* 6.8mm Fin Spacing (3.7 FPI)

500mm Diameter Fan Models - 4mm Fin Spacing (6 FPI)291550 CH4C1/50E-1 8310 7895 7320 26

1 x 500 750 1.30 18000

3 x 850

2 x 850 5/8 1 1/8

1420

670 750

CH4D1/50E-1 10300 9785 7110 25 5 x 850

291554 CH4E1/50E-1 10990 10441 6920 246 x 850

CH4G1/50E-1 12570 11942 6510 22

7/8

1 3/8 291558 CH4C2/50E-1 17000 16150 14640 27

2 x 500 1500 2.60 36000

3 x 1650

2 x 1650 2500CH4D2/50E-1 20950 19903 14220 26 5 x 1650

15/8 291562 CH4E2/50E-1 22420 21299 13840 256 x 1650

291564 CH4G2/50E-1 26120 24814 13020 23

291566 CH4D3/50E-1 30770 29232 21330 26

3 x 500 2250 3.90 54000

5 x 2450

2 x 2450 21/8 3580CH4E3/50E-1 34820 33079 20760 25 6 x 2450 1 1/8 291570 CH4G3/50E-1 36800 34960 19530 23 6 x 2450

Capacity Correction FactorsSuction Temp. ˚C -36 -33 -30 -27 -24 -21 -18 -15 -12

Capacity Multiplier

R404A, R507 0.77 0.83 0.89 0.94 1.00 1.06 1.12 1.19 1.25

R22 0.81 0.86 0.91 0.95 1.00 1.05 1.1 1.17 1.23

X Capacity for suction temperatures other than -24˚C can be calculated from the correction table.

X * Internally equalised TX Valve. All other models require externally equalised TX Valves

10.global brands - local service

Actrol reserves the right to make changes at any time to the information and specifications of products described in this literature without notice or obligation. Images are representative only. For specific detail on any product please contact your local Actrol branch.

A selection of our range

11.global brands - local service

1300 ACTROL

880120 CAB0415

actrol.com.au