19
1 Standards and Calibration Laboratory, SCL Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL) Speaker: Chung Yin, Poon Standards and Calibration Laboratory (SCL) The Government of the Hong Kong Special Administrative Region

Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

  • Upload
    sissy

  • View
    50

  • Download
    0

Embed Size (px)

DESCRIPTION

Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL). Speaker: Chung Yin, Poon Standards and Calibration Laboratory (SCL) The Government of the Hong Kong Special Administrative Region. Learning Objectives. To introduce the meaning of flickers in power line - PowerPoint PPT Presentation

Citation preview

Page 1: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

1Standards and Calibration Laboratory, SCL

Evaluation of Flicker Severity in Standards and Calibration

Laboratory (SCL)

Speaker: Chung Yin, PoonStandards and Calibration Laboratory (SCL)The Government of the Hong Kong Special

Administrative Region

Page 2: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

2Standards and Calibration Laboratory, SCL

Learning Objectives

• To introduce the meaning of flickers in power line

• To describe a method for calibrating flicker source and flickermeter

Page 3: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

3Standards and Calibration Laboratory, SCL

Introduction

• Flicker is the change in brightness of a lamp due to rapid fluctuations in the voltage of the power supply

• Cause disturbance to human visual perception system

• Voltage change characteristic at the terminals of the equipment under test, such as microwave ovens, washing machines

• All types of voltage fluctuations may be assessed by direct measurement using a flickermeter

Page 4: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

4Standards and Calibration Laboratory, SCL

Introduction

Source: Figure B.1, IEC 61000-4-15-2010 Flickermeter - Functional and design specifications

Page 5: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

5Standards and Calibration Laboratory, SCL

Evaluation of flicker parameters

• Flickermeter (Functional and design specification in IEC 61000-4-15)

• Flicker source (Limits of voltage changes produced by an equipment in IEC 61000-3-3)

• SCL developed a system to evaluate the accuracy of flicker source and flicker measurement functions of flickermeter

Page 6: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

6Standards and Calibration Laboratory, SCL

Operating Principle• Flicker waveform is modeled as an amplitude

modulated (AM) signal in power line (120 V / 230 V)

Page 7: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

7Standards and Calibration Laboratory, SCL

Operating Principle

• Relative voltage change / Voltage fluctuation

• Vupper: Amplitudes of upper sideband

• Vlower: Amplitude of lower sideband

• Vcarrier: Amplitude of the carrier

Page 8: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

8Standards and Calibration Laboratory, SCL

Calibration of flicker source - Setup

Page 9: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

9Standards and Calibration Laboratory, SCL

Resistive voltage divider

Page 10: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

10Standards and Calibration Laboratory, SCL

Calibration of flicker source - Setup

Page 11: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

11Standards and Calibration Laboratory, SCL

Calibration of flicker source

• Voltages of lower sideband (Vlower), carrier (Vcarrier) and upper sideband (Vupper) in dB are measured by signal analyzer

• Accuracy of the voltage fluctuation of standard flicker source can be determined

Page 12: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

12Standards and Calibration Laboratory, SCL

Calibration of flickermeter

• Flickermeters under test are calibrated by direct comparison with the standard flicker source

• Calibration in terms of voltage fluctuation and modulating frequency

• Instantaneous flicker sensation (Pinst) will be compared against the theoretical values as illustrated in IEC 61000-4-15

Page 13: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

13Standards and Calibration Laboratory, SCL

Calibration of flickermeter - Setup

Page 14: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

14Standards and Calibration Laboratory, SCL

What to be measured?

Page 15: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

15Standards and Calibration Laboratory, SCL

Measurement uncertainties

• Depends on– Amplitude accuracy of signal analyzer– Performance of standard flicker source– Calibration setup

Page 16: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

16Standards and Calibration Laboratory, SCL

Maximum uncertainty of voltage fluctuation measurement

Page 17: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

17Standards and Calibration Laboratory, SCL

Measurement uncertainties

• Flicker source: Measurement uncertainty < 0.03% at 95% confidence level

• Flickermeter: Measurement uncertainty < 0.3% for determination of flicker severities at 95% confidence level

• Type testing of Class F1 flickermeters according to IEC 61000-4-15– Tolerance of 8% in Pinst for sinusoidal voltage changes

Page 18: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

18Standards and Calibration Laboratory, SCL

Ratio between the specifications of standard flicker source and maximum measurement uncertainty (TUR)

Page 19: Evaluation of Flicker Severity in Standards and Calibration Laboratory (SCL)

19Standards and Calibration Laboratory, SCL

Thank you