Superior Impact, Strength and Crack Resistance on Carbon Steels • All position welding electrode • Easy-to-use, easy slag removal, versatile electrode • Non-sulfur bearing striker tip for instant starts • Good re-striking characteristics • Moisture guard coating with non-conductive flux coating • High strength combined with high elongation EutecTrode 966 ® WELDING

EutecTrode-966

Embed Size (px)

DESCRIPTION

http://www.castolin.com/sites/default/files/product/downloads//EutecTrode-966.pdf

Citation preview

Superior Impact, Strength and Crack Resistance on Carbon Steels

• All position welding electrode

• Easy-to-use, easy slag removal, versatile electrode

• Non-sulfur bearing striker tip for instant starts

• Good re-striking characteristics

• Moisture guard coating with non-conductive fl ux coating

• High strength combined with high elongation

EutecTrode 966®

WELDING

DESCRIPTION:

EutecTrode 966 is a high quality electrode for low alloy, medium carbon and high tensile steels. Featuring rapid start, smooth arc control and easy slag removal. EutecTrode 966 was developed for joining and build-up on carbon steels, dirty steels, alloy steels, free machining steels and “problem“ steels without cracking or porosity. It provides excellent physical properties and is recommended where high strength, machinable, ductile, dense, crack-free and porosity-free welds are of paramount importance.

WELDING PARAMETERS:

Preparation: The area to be welded should be free of sur-face contamination such as rust, scale, grease or fatigued metal. Preheat heavy section or hardenable grades of steel to 400° F (200°C). Use carbon equivalency on steel to estab-lish recommended preheats.

Technique: For highest X-Ray quality welds, maintain a short arc gap and chip slag between passes. On vertical welds, start at the bottom and weave slightly, pausing at the edges. For root passes, at a minimum gap (3/32“ for 1/8“ electrodes) and run stringer beads. For fill and cover passes a weaving technique is best employed.

Post-welding: Allow parts to slow cool in still air.

Statement of Liability: Due to variations inherent in specifi c applications, the technical information contained herein, including any information as to suggested product applications or results, is presented without representation or warranty, expressed or implied. Without limitation, there are no warranties of merchantability or of fi tness for a particular purpose. Each process and application must be fully evaluated by the user in all respects, including suitability, compliance with applicable law and non-infringement of the rights of others, and Eutectic Corporation and its affi liates shall have no liability in respect thereof.

YOUR RESOURCE FOR PROTECTION, REPAIR AND JOINING SOLUTIONS

Eutectic CorporationN94 W14355 Garwin Mace DriveMenomonee Falls, WI 53051 USAP 800-558-8524 • F 262-255-5542www.eutecticusa.com

Eutectic Canada428, rue Aime VincentVaudreuil-Dorion, Quebec J7V 5V5Phone: (800) 361-9439Fax: (514) 695-8793www.eutectic-na.com

Eutectic MexicoKM 36.5 AutopistaMexico-Quertaro54730 Cautitlan-IzcalliEstado de Mexico, MexicoPhone: 011 (52) 55-5872-1111e-mail: [email protected]

966-05-04-11© 2008, Eutectic Corporation, ® Reg. T.M., Printed in the U.S.A.

TYPICAL APPLICATIONS:

General fabrication and maintenance of structural work, construction and earthmoving equipment, mining and quarry machinery repairs, truck and trailer frames, mate-rial handling equipment, farm implements and rail equip-ment.

TECHNICAL DATA:

Tensile Strength: 86,000 psi (595 N/mm2)Yield Strength: 75,000 psi (520 N/mm2)Elongation (1=5d): 36%Polarity: AC/DC (+) All Position

WARNINGProtect yourself and others. Read and understand this warning. THIS PRODUCT CONTAINS CHROMIUM AND/OR NICKEL which are listed by OSHA, NTP, or IARC as being a carcinogen or potential carcinogen. Use of this product may expose you or others to fumes and gases at levels exceeding those established by the American Conference of Governmental Industrial Hygienists (ACGIH) or the Occupational Safety and Health Administration (OSHA). READ AND COMPLY WITH THE OSHA PERMISSIBLE EXPOSURE LIMITS FOR HEXAVALENT CHROMIUM (CrVi), Fed. Reg. 71-10099. MANGANESE & RELATED COMPOUNDS SUCH AS MANGANESE DIOXIDE: Overexposure to manganese and its compounds may cause metal fume fever characterized by chills, fever, upset stomach, vomiting, irritation of the throat and aching of the body. Excessive overexposure may affect the central nervous system. Symptoms may include muscular weak ness and tremors. Behavioral changes and changes in handwriting may also appear. Workers exposed to manganese and its compounds should receive quarterly medical examinations of early detection of manganese poisoning. FUMES AND GASES can be dangerous to your health. Certain medical studies have suggested that NERVOUS SYSTEM and/or LUNG DAMAGE can result from exposure to welding fumes and gases through the use of some electrodes. ARC RAYS can injure eyes and burn skin. ELECTRIC SHOCK can kill. • Before use, read and understand the Material Safety Data Sheets (MSDS), the manufacturer’s instructions, and follow your employer’s safety practices • Keep your head out of the fumes. • Use enough ventilation, exhaust at the arc, or both, to keep fumes and gases from your breathing zone and the general area. Respirators may be needed and should be chosen by the employer based on workplace conditions and contaminant levels. For information regarding a respiratory protection program, see OSHA 1910.134 requirements. • Wear correct eye, ear, and body protection. • Do not touch live electrical parts. • In case of medical emergency, call for medical aid. •See American National Standard Z49.1, Safety in Welding and Cutting, published by the American Welding Society, 550 N.W. LeJeune Road, Miami, FL 33135; and OSHA Safety and Health Standards, 29CFR 1910, available from the U.S. Government Printing Offi ce, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954. WARNING: This product contains or produces chemicals known to the State of California to cause cancer and birth defects (or other reproductive harm). (California Health & Safety Code Section 25249.5 et seq.)

Recommended Amperages

Temp. 72°F (22°C) 0°F (-18°C) -20°F (-29°C) -40°F (-40°C)

Ft. Lbs. 110 100 90 60

Joules 149 136 122 81

Expected Charpy V-notch impact properties (as welded).

Diameter: 3/32” (2.4mm) 1/8” (3.2mm) 5/32” (4.0mm)

Amperage: 60-100 110-150 140-200

Part No.: 966-24-5K 966-32-5K 966-40-5K