EST Technology Co., Ltd Report No. ESTE-R1801024 Page 1 of 153
ETSI EN 301 489-1 & -3 TEST REPORT for
Samson Technologies Corp
Wireless Microphone UHF Transmitter
UHF WIRELESS RECEIVER
Model Number: AH8, AG8, ATX, CR88, CR99
Prepared for: Samson Technologies Corp
278-B DUFFY AVENUE, HICKSVILLE, NY 11801
Prepared By: EST Technology Co., Ltd.
Chilingxiang, Qishantou, Santun, Houjie, Dongguan, Guangdong, China
Tel: 86-769-83081888-808
Report Number: ESTE-R1801024
Date of Test: Dec. 01 ~ 31, 2017 & Feb. 08 ~ Mar. 09, 2018
Date of Report: Mar. 12, 2018
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 2 of 153
TABLE OF CONTENTS
Description Page
Test Report Declaration…………………………………………….………………..…..5
1. SUMMARY OF MEASUREMENTS AND RESULTS ................................................................... 5 1.1. Standard description .......................................................................................................................... 5 1.2. Compliance with ETSI EN301 489-1 & Final Draft ETSI EN 301 489-3 ........................................ 6
2. GENERAL INFORMATION ........................................................................................................... 7 2.1. Description of Device (EUT) ............................................................................................................ 7 2.2. Test Facilities .................................................................................................................................... 8 2.3. Measurement uncertainty .................................................................................................................. 9 2.4. Assistant equipment used for test .................................................................................................... 10 2.5. EUT Configuration and operation conditions for test. .................................................................... 11 2.6. Test mode ........................................................................................................................................ 12
3. CONDUCTED DISTURBANCE AT MAINS TERMINALS TEST ............................................. 13 3.1. Test Equipment ............................................................................................................................... 13 3.2. Block Diagram of Test Setup .......................................................................................................... 13 3.3. Operating Condition of EUT ........................................................................................................... 13 3.4. Test Procedure ................................................................................................................................. 14 3.5. Conducted Disturbance at Mains Terminals Test Results ............................................................... 14 3.6. Test Data ......................................................................................................................................... 15
4. RADIATED EMISSION TEST ...................................................................................................... 33 4.1. Test Equipment ............................................................................................................................... 33 4.2. Block Diagram of Test Setup .......................................................................................................... 34 4.3. Operating Condition of EUT ........................................................................................................... 35 4.4. Test Procedure ................................................................................................................................. 35 4.5. Test Results ..................................................................................................................................... 35 4.6. TEST DATA ................................................................................................................................... 36
5. HARMONIC CURRENT TEST .................................................................................................... 72 5.1. Test Equipment ............................................................................................................................... 72 5.2. Block Diagram of Test Setup .......................................................................................................... 72 5.3. Operating Condition of EUT ........................................................................................................... 72 5.4. Test Procedure ................................................................................................................................. 72 5.5. Test Results ..................................................................................................................................... 72
6. VOLTAGE FLUCTUATIONS & FLICKER TEST ....................................................................... 73 6.1. Test Equipment ............................................................................................................................... 73 6.2. Block Diagram of Test Setup .......................................................................................................... 73 6.3. Operating Condition of EUT ........................................................................................................... 73 6.4. Test Procedure ................................................................................................................................. 73 6.5. Test Results ..................................................................................................................................... 73
7. IMMUNITY PERFORMANCE CRITERIA ................................................................................. 79 8. ELECTROSTATIC DISCHARGE IMMUNITY TEST ................................................................. 80
8.1. Test Equipment ............................................................................................................................... 80 8.2. Block Diagram of Test Setup .......................................................................................................... 80 8.3. Test Levels and Performance Criteria ............................................................................................. 80 8.4. Operating Condition of EUT ........................................................................................................... 80 8.5. Test Procedure ................................................................................................................................. 81 8.6. Test Information .............................................................................................................................. 81 8.7. Test Results ..................................................................................................................................... 82
9. RF FIELD STRENGTH SUSCEPTIBILITY TEST ...................................................................... 83 9.1. Test Equipment ............................................................................................................................... 83 9.2. Block Diagram of Test Setup .......................................................................................................... 84 9.3. Test Severity Level and Performance Criteria ................................................................................ 85 9.4. Operating Condition of EUT ........................................................................................................... 85
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 3 of 153
9.5. Test Procedure ................................................................................................................................. 85 9.6. Test Information .............................................................................................................................. 85 9.7. Test Results ..................................................................................................................................... 86
10. ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST ................................................ 87 10.1. Test Equipment ............................................................................................................................... 87 10.2. Block Diagram of Test Setup .......................................................................................................... 87 10.3. Operating Condition of EUT ........................................................................................................... 87 10.4. Test Procedure ................................................................................................................................. 87 10.5. Test Information .............................................................................................................................. 88 10.6. Test Results ..................................................................................................................................... 88
11. SURGE TEST ................................................................................................................................ 89 11.1. Test Equipment ............................................................................................................................... 89 11.2. Block Diagram of Test Setup .......................................................................................................... 89 11.3. Severity Levels and Performance Criterion .................................................................................... 89 11.4. Operating Condition of EUT ........................................................................................................... 89 11.5. Test Procedure ................................................................................................................................. 90 11.6. Test Information .............................................................................................................................. 90 11.7. Test Results ..................................................................................................................................... 91
12. INJECTED CURRENTS SUSCEPTIBILITY TEST ..................................................................... 92 12.1. Test Equipment ............................................................................................................................... 92 12.2. Block Diagram of Test Setup .......................................................................................................... 92 12.3. Severity Levels and Performance Criterion .................................................................................... 92 12.4. Operating Condition of EUT ........................................................................................................... 92 12.5. Test Procedure ................................................................................................................................. 93 12.6. Test Information .............................................................................................................................. 93 12.7. Test Results ..................................................................................................................................... 94
13. VOLTAGE DIPS AND INTERRUPTIONS TEST ........................................................................ 95 13.1. Test Equipment ............................................................................................................................... 95 13.2. Block Diagram of Test Setup .......................................................................................................... 95 13.3. Operating Condition of EUT ........................................................................................................... 95 13.4. Test Procedure ................................................................................................................................. 95 13.5. Test Information .............................................................................................................................. 95 13.6. Test Results ..................................................................................................................................... 96
14. PHOTOGRAPHS OF TEST SETUP ............................................................................................. 97 14.1. Set-up for Conducted disturbance at mains terminals test .............................................................. 97 14.2. Set-up for Radiated(30MHz-1GHz) test ....................................................................................... 102 14.3. Set-up for Radiated(Above 1GHz) test ......................................................................................... 107 14.4. Set-up for Harmonic current and Voltage fluctuations & flicker test ........................................... 111 14.5. Set-up for Electrostatic discharge immunity test .......................................................................... 114 14.6. Set-up for Electrical fast transient/burst immunity test ................................................................. 117 14.7. Set-up for Surge test ...................................................................................................................... 120 14.8. Set-up for Injected currents susceptibility test .............................................................................. 123 14.9. Set-up for Voltage dips and interruptions test ............................................................................... 126
15. PHOTOGRAPHS OF EUT .......................................................................................................... 129
EsT TechⅡ oIo£Ⅳ Co。.LtdecⅡⅡo o。 ,
App1icao【钅:
Ac【d扭嗡 :
Satuson Techno1ogies C唧
278ˉB DLyFFY AⅦEl殴旺.Ⅱ1CKsVlLLE多 NY Ⅱ801
眼铷 涯簸搬涠
」蔑`蛐
:
S恿琏 1s◇强 T晚 缸囟o銮θ睡 G§ CoFp
它了⒏B酗馏 FY AV冁 )H跹黑忑v邑LE,N¥ 乏昱80至
E。 U。T:Wireless M如 ropllOIle1刀 F Tra11sm巛 er
UHF WIRELEss RECE1Ⅴ ER
Modd Nu血 ber:
AH8,AG8,ATX,CR88J=R99N翻睫:A鼓鑫、AG思 aEId ΛTX afc酊曰F TraRlslni笈er,CR88and CR99a浔 LRHF
葩 i:∶∶∶∶∶丨:∶!∶1ⅤER.G:AⅡ罗钿 d嗒冱 T∶∶9ii∶∶:991【
∶丨liifeFeilcθ aItlO11gisjust tlle appcaFance.‘cAH8、 ATX” a1ad“AG8,’ have血 e salllc orGuitly theoγ a11d frcquen。 y
ba11d9tbe d茹∝α⒑e h GOns抵 Gtion,PCB layout,ratlng弼旧model naane.‘℃R8扩
’and“ (珏⒚9” 苑ave the蛇瑟弓orcui饣y tll浒叩 a】ld frcquenGy band,tllc
d磴蒈幽嚣羽嘧ε重退 ¢螂 妇R朝爿眭oEk弼 B及avoug.rck如 江g镶n懑 蓄狂◇det naIIte。
Pc|wer su9p盱∶
AL】8&A11X∶DC3,7V from50011△AL⒈ion B引走αyDC5Ⅴ 如∞l adaptσ i⒒put AC lθ0碗40V50蹈 0HzronlⅤ for oh盯焦in窍
AG8∶ DC1.5V tol】 1率 AA B,a守扛助ry
旺Ι辶8器 鑫 ∈I乏99∶
DC15Ⅴ from adaoterinout AC100-240V50/60Hz
Test Volt曜¢
AH⒏ DC3,7VDC5Vn⒃殂 amDteF iⅡ¢ut AC230V//s0Hz
AG8∶ DC1.5VC黯s8《芒:暂:Cl[l∶∶:;,9∶
DC15V&om adaDterinDut AC230Ⅴ
Trade Name: sAMs0N seⅡ斑No∶
Date of娅 p狂 Dc移,01分 2fj【 7 Da把 ofTestDec.01~31,2017`艮 Fcb,08~M龛r n9 9o1R9o葱 R
Test sPg滂旺猊 伍oⅡ :
露Ts1邋N3¤童剧:锣哆宀▲芰△/a。1.1:a苷 B至了̄喀2
Final Draft ETsI EN301489ˉ 3V2.1.1:2017ˉ03
Test Rlesult: Thc devIGe dcs‘ )门Ftibed abovc is testcd by EsT Tcchnology Co,,Ltd., The
F1【eas1remetlt resu1奄 s were GOnt西n¢d in this test repolt atld EST Tecllnology
南 .,ntd.啷 搽 铷 豳 Gd猢 l re叩噬 蚰 uli够 f。r tlle acc盯 a呷 and cO】△pl韵田 ess
搬:巍貉弼 In蛳 搠摁·盎胝◇卩钮is阝哪耐 巍镞鹂 巍at确g EUT to b孕
teGhn忆 ally complianGe Ⅵi伍 曲e ETsI EN301489-1宀 3requkements.
This repo琏 applie$to above te茹 ed salllple only alad shalI not be reproduced
亟瓣 鼬 o菠 诫 tten appri△ 谰 oFEsT T饿哏
b拶 c⒊
锼 0轳 亍 \
巍缫 ;螅 备戚蛋峦瞳 To猡 £臃 狂狂垩丫
矧1G拥a盎.驳遴f 蠡
0εLer Asp刨确:坻扌A斑各夯蹭 y泗疗c珉 s氵 £助芰丬P Pn.I· 9c汀 丿勿喃〃F刁 弼 扌甜 ″·贫 久F=符耐 婢 拦f镢各勋 旦 u「 召孑贺功 渤 钾 ∮扌耐 eF招 ‘招饣
Ξ珏Jj矿csF罗吃卩c尹¢必 战饣s汩 cI涩 si热酗 妒t,【l而矮
'痴
,″ c,for9妒 s四灬p圣e硭 ¢f,o、召JP9四r山3″c,Jf,roar£峦 ,fr峦 乃orp留猢 F匝ed妤 各召
啕汔邪P晶廴饣铂描殳扌贞盱洫 饿ε加 w讠茹鼬 盯扌蝇 锇 确哆型冫汛9rg'《旷猡 勋 ‘助饣扔锣 「o.,ェ跛
EsT Tech11o1◇ gy Co., Ltd Rel,o扌 t lXIo‘ EsTE-R1801024 Page4of153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 5 of 153
1. SUMMARY OF MEASUREMENTS AND RESULTS
1.1. Standard description
ETSI EN 301 489 -1 V2.1.1 (2017): ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU and the essential requirements of article 6 of Directive 2014/30/EU. Final Draft EN 301 489-3 V2.1.1 (2017): ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz; Harmonised Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 6 of 153
1.2. Compliance with ETSI EN301 489-1 & Final Draft ETSI EN 301 489-3
CLAUSE TEST PARAMETER APPLICATION BASIC STANDARF OR
TEST METHOD RESULTS
EMC emission
8.2 Radiated emission Enclosure of ancillary
equipment EN 55032: 2015 PASS
8.3 Conducted emission DC power input/output
port EN 55032: 2015 N/A
8.4 Conducted emission AC mains input/output
port EN 55032: 2015 PASS
8.5 Harmonic Current
Emissions AC mains input port EN 61000-3-2: 2014 N/A
8.6 Voltage Fluctuation
& Flicker AC mains input port EN 61000-3-3: 2013 PASS
8.7 Conducted emission Wired network port EN 55032: 2015 N/A
Immunity
9.2 RF electromagnetic
field Enclosure
EN 61000-4-3: 2006+A1: 2008+A2: 2010
PASS
9.3 Electrostatic Discharge
Enclosure EN 61000-4-2: 2009 PASS
9.4 Fast transients common mode
Signal, wired network and control ports, DC and AC power ports
EN 61000-4-4: 2012 PASS
9.5 RF Common mode Signal, wired network and control ports, DC and AC power ports
EN 61000-4-6: 2014+AC: 2015
PASS
9.6 Transients and
Surges DC power input ports
for vehicular use ISO 7637-2: 2011 N/A
9.7 Voltage dips and
interruptions AC mains power input
ports EN 61000-4-11: 2004 PASS
9.8 Surges, line to line and line to ground
AC mains power input ports, wired network
ports EN 61000-4-5: 2014 PASS
N/A is an abbreviation for Not Applicable.
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 7 of 153
2. GENERAL INFORMATION
2.1. Description of Device (EUT)
Product Name : Wireless Microphone UHF Transmitter Model Number : AH8, AG8
Modulation : FM(F3E), Only TX Operation frequency : 470.125MHz-493.975MHz 863. 05MHz – 864.95MHz Number of channel : 16 9 Antenna : Integral Antenna, 1.94dBi Software : 1.0 Firmware : 1.0 Temperature Range : -10°C ~ +45°C
Product Name : UHF WIRELESS RECEIVER Model Number : CR88, CR99
Modulation : FM(F3E), Only RX Operation frequency : 470.125MHz-493.975MHz 863. 05MHz – 864.95MHz Number of channel : 16 9 Antenna : External antenna, 1.94dBi Software : 1.0 Firmware : 1.0 Temperature Range : -10°C ~ +45°C
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 8 of 153
2.2. Test Facilities
EMC Lab : Certificated by CNAS, CHINA Registration No.: L5288 Date of registration: November 13, 2017 Certificated by A2LA, USA Registration No.: 4366.01 Date of registration: November 07, 2017 Certificated by FCC, USA Designation Number: CN1215 Registration No.: 722932 Date of registration: November 21, 2017 Certificated by Industry Canada Registration No.: 9405A Date of registration: December 03, 2015 Certificated by VCCI, Japan Registration No.: R-13663; C-14103 Date of registration: July 25, 2017 This Certificate is valid until: July 24, 2020 Certificated by TUV Rheinland, Germany Registration No.: UA 50195514 0001 Date of registration: February 07, 2015
Certificated by TUV/PS, Shenzhen Registration No.: SCN1017 Date of registration: January 27, 2011
Certificated by Intertek ETL SEMKO Registration No.: 2011-RTL-L2-64 Date of registration: April 28, 2011 Certificated by Nemko, Hong Kong Registration No.: 175193 Date of registration: May 4, 2011
Name of Firm : EST Technology Co., Ltd.
Site Location : Chilingxiang, Qishantou, Santun, Houjie, Dongguan,
Guangdong, China
The Sub-contractor test site and location (R/S)
: Guangdong Dongguan Quality Supervision Testing CenterNo.2 South Industry Road, Dongguan Songshan Lake Sci.&Tech.Industrial Park Guangdong Province China
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 9 of 153
2.3. Measurement uncertainty
Test Item Uncertainty
Uncertainty for Conduction emission test ±3.48dB
Uncertainty for spurious emissions test (30MHz-1GHz)
±4.60 dB(Polarize: H)
±4.68 dB(Polarize: V)
Uncertainty for spurious emissions test (1GHz to 18GHz)
±4.96dB
Uncertainty for radio frequency 7×10-8
Uncertainty for conducted RF Power 0.20dB
Uncertainty for Power density test 0.26dB
Note:This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 10 of 153
2.4. Assistant equipment used for test
2.4.1. Adapter 1
M/N : KSAS0050500100D5U
Manufacturer : Ktec
AC : AC 100-240V~50/60Hz
Output : DC 5.0V, 1.0A
2.4.2. Adapter 2
M/N : KSAS0121500080D5
Manufacturer : Ktec
AC : AC 100-240V 50/60Hz 0.4A
Output : DC 15V/0.8A
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 11 of 153
2.5. EUT Configuration and operation conditions for test.
or
(EUT: Wireless Microphone UHF Transmitter/ UHF WIRELESS RECEIVER)
1 DC Line1 Unshielded, Detachable 1.6m
2 DC Line2 Unshielded, Detachable 1.8m
AC Mains Adapter 1 EUT
(AH8)
EUT (CR88/CR99
DC Line1
Adapter 2 AC Mains DC Line2
EUT (AH8/AG8)
Core
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 12 of 153
2.6. Test mode
2.6.1. TX+RX Mode(470MHz-494MHz)
2.6.2. TX+RX Mode(863MHz-865MHz)
2.6.3. RX Mode(470MHz-494MHz)
2.6.4. RX Mode(863MHz-865MHz)
2.6.5. Charging
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 13 of 153
3. CONDUCTED DISTURBANCE AT MAINS TERMINALS TEST
3.1. Test Equipment
3.1.1. For AC Main Port
3.2. Block Diagram of Test Setup
3.3. Operating Condition of EUT
3.3.1. Setup the EUT and simulator as shown as Section 2.5.
3.3.2. Turned on the power of all equipment.
3.3.3. Reference 2.6.
Equipment Manufacturer Model No. Serial No. Last Cal. Next Cal. EMI Test Receiver Rohde & Schwarz ESHS30 832354 June 17,17 1 Year Artificial Mains Networ Rohde & Schwarz ENV216 101260 June 17,17 1 Year Pulse Limiter Rohde & Schwarz ESH3-Z2 101100 June 17,17 1 Year Test Software Audix e3-6.111221
a N/A N/A N/A
Calibration Lab: CEPREI Calibration and Testing Center
EUT Peripheral
LISN LISNReceiver
PC System
80cm
80cm
>80cm
50Ω Impedance
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 14 of 153
3.4. Test Procedure
3.4.1. For AC Main Port (Main Terminal)
The EUT was placed on a non-metallic table, 80cm above the ground plane. The EUT Power connected to the power mains through a line impedance stabilization network (L.I.S.N. 1#). This provided a 50-ohm coupling impedance for the EUT (Please refer to the block diagram of the test setup and photographs). Both sides of power line were checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipments and all of the interface cables were changed according to EN 55032 Class A on conducted Disturbance test.
3.5. Conducted Disturbance at Mains Terminals Test Results
PASS. (All emissions not reported below are too low against the prescribed limits.)
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 15 of 153
3.6. Test Data
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 16 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 17 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 18 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 19 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 20 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 21 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 22 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 23 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 24 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 25 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 26 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 27 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 28 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 29 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 30 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 31 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 32 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 33 of 153
4. RADIATED EMISSION TEST
4.1. Test Equipment
4.1.1. For frequency range 30MHz~1GHz (At Anechoic Chamber)
4.1.2. For frequency range 1GHz~6GHz (At Anechoic Chamber)
Equipment Manufacturer Model No. Serial No. Last Cal. Next Cal.
EMI Test Receiver Rohde & Schwarz ESR7 101780 June 17,17 1 Year Horn Antenna SCHWARZBECK BBHA 9120 D 8128-290 June 08,17 1 Year Signal Amplifier SCHWARZBECK BBV9718 9718-212 June 17,17 1 Year
Test Software Audix e3-6.111221a N/A N/A N/A Calibration Lab: CEPREI Calibration and Testing Center
Equipment Manufacturer Model No. Serial No. Last Cal. Next Cal. EMI Test Receiver Rohde & Schwarz ESR7 101780 June 17,17 1 Year Bilog Antenna Teseq CBL 6111D 25872 June 08,17 1 Year Test Software Audix e3-6.111221a N/A N/A N/A Calibration Lab: CEPREI Calibration and Testing Center
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 34 of 153
4.2. Block Diagram of Test Setup
4.2.1. In Anechoic Chamber Test Setup Diagram for 30MHz~1000MHz
4.2.2. In Anechoic Chamber Test Setup Diagram for 1-6GHz
ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
3m
EUT and Support System
TURN TABLE (FIBRE GLASS) 1.5m(L)*1.0m(W)*0.8m(H)
Receiver
Semi-anechoic Chamber
ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
3m
EUT and Support System
TURN TABLE (FIBRE GLASS) 1.5m(L)*1.0m(W)*0.8m(H)
Receiver
Semi-anechoic Chamber
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 35 of 153
4.3. Operating Condition of EUT
4.3.1. Setup the EUT and simulator as shown as Section 2.5.
4.3.2. Turned on the power of all equipment.
4.3.3. Reference 2.6.
4.4. Test Procedure
The EUT was placed on a non-metallic table, 80 cm above the ground plane inside a semi-anechoic chamber. An antenna was located 3m or 10m from the EUT on an adjustable mast. A pre-scan was first performed in order to find prominent radiated emissions. For final emissions measurements at each frequency of interest, the EUT were rotated and the antenna height was varied between 1m and 4m in order to maximize the emission. Measurements in both horizontal and vertical polarities were made and the data was recorded. In order to find the maximum emission, the relative positions of equipments and all the interface cables were changed according to EN 301489 on Radiated Disturbance test.
The bandwidth setting on the test receiver (R&S TEST RECEIVER ESCI) is 120 kHz.
The resolution bandwidth of the Agilent Spectrum Analyzer E4408B was set at 1MHz. (For above 1GHz) The frequency range from 30MHz to 1000MHz was pre-scanned with a peak detector and all final readings of measurement from Test Receiver are Quasi-Peak values. The frequency range from 1GHz to 6GHz was checked with peak and average detector, measurement distance is 3m in 10m chamber.
4.5. Test Results
PASS. (All emissions not reported below are too low against the prescribed limits.)
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 36 of 153
4.6. TEST DATA
30MHz-1GHz
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 37 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 38 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 39 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 40 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 41 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 42 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 43 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 44 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 45 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 46 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 47 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 48 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 49 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 50 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 51 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 52 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 53 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 54 of 153
Above 1GHz
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 55 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 56 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 57 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 58 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 59 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 60 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 61 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 62 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 63 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 64 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 65 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 66 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 67 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 68 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 69 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 70 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 71 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 72 of 153
5. HARMONIC CURRENT TEST
5.1. Test Equipment
Equipment Manufacturer Model No. Serial No. Last Cal. Next Cal. Power Analyzer California Instruments 3001LX-208-CTS 1642A03400 June 17,17 1 Year Voltage Source California Instruments 3001LX-208 1641A00463 June 17,17 1 Year Test Software California Instruments CTS N/A N/A N/A Calibration Lab: CEPREI Calibration and Testing Center
5.2. Block Diagram of Test Setup
5.3. Operating Condition of EUT
5.3.1. Setup the EUT and simulator as shown as Section 2.5.
5.3.2. Turned on the power of all equipment.
5.3.3. Reference 2.6.
5.4. Test Procedure
The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated to produce the maximum harmonic components under normal operating conditions for each successive harmonic component in turn. The correspondent test program of test instrument to measure the current harmonics emanated from EUT is chosen. The measure time shall be not less than the necessary for the EUT to be exercised.
5.5. Test Results
N/A There is no need for Harmonics test to be performed on this product (rated power is less than 75W) in accordance with EN 61000-3-2:2014. For further details, please refer to Clause 7 of EN 61000-3-2:2014 which states: “For the following categories of equipment, limits are not specified in this edition of the standard: - equipment with a rated power of 75W or less, other than lighting equipment.”
EUT
80cm
AC Main
Power Analyzer (Compliance Test System)
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 73 of 153
6. VOLTAGE FLUCTUATIONS & FLICKER TEST
6.1. Test Equipment
Same as Section 5.1.
6.2. Block Diagram of Test Setup
Same as Section 5.2.
6.3. Operating Condition of EUT
6.3.1. Setup the EUT and simulator as shown as Section 2.5.
6.3.2. Turned on the power of all equipment.
6.3.3. Reference 2.6.
6.4. Test Procedure
The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated to produce the most unfavorable sequence of voltage changes under normal conditions During the flick measurement, the measure time shall include that part of whole operation changes. The observation period for short-term flicker indicator is 10 minutes and the observation period for long-term flicker indicator is 2 hours.
6.5. Test Results
PASS. Please refer to the following page.
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 74 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 75 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 76 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 77 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 78 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 79 of 153
7. IMMUNITY PERFORMANCE CRITERIA
The test results shall be classified in terms of the loss of function or degradation of performance of the equipment under test, relative to a performance level by its manufacturer or the requestor of the test, or the agreed between the manufacturer and the purchaser of the product. Definition related to the performance level: 1. Based on the used product standard 2. Based on the declaration of the manufacturer, requestor or purchaser
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 80 of 153
8. ELECTROSTATIC DISCHARGE IMMUNITY TEST
8.1. Test Equipment
Equipment Manufacturer Model No. Serial No. Last Cal. Cal. IntervalESD Tester HAEFELY ONYX16 174153 June 16,17 1 Year Calibration Lab: CEPREI Calibration and Testing Center
8.2. Block Diagram of Test Setup
8.3. Test Levels and Performance Criteria
Severity Level Test Voltage
Contact Discharge (kV)Test Voltage
Air Discharge (kV)Performance
criterion 1. 2 2
B 2. 4 4 3. 6 8 4. 8 15
X Special Special
8.4. Operating Condition of EUT
Refer to 2.6.
EUT
Horizontal Coupling PlaneESD Generator
470kΩx2 80cm
Wall
Vertical Coupling Plane 0.1m>1m
470kΩx2
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 81 of 153
8.5. Test Procedure
8.5.1. Air Discharge:
The test was applied on non-conductive surfaces of EUT. The round discharge tip of the discharge electrode was approached as fast as possible to touch the EUT. After each discharge, the discharge electrode was removed from the EUT. The generator was re-triggered for a new single discharge and repeated 20 times for each pre-selected test point. This procedure was repeated until all the air discharge completed
8.5.2. Contact Discharge:
All the procedure was same as Section 8.7.1. except that the generator was re-triggered for a new single discharge and repeated 50 times for each pre-selected test point. The tip of the discharge electrode was touching the EUT before the discharge switch was operated.
8.5.3. Indirect discharge for horizontal coupling plane
At least 20 single discharges were applied to the horizontal coupling plane, at points on each side of the EUT. The discharge electrode positions vertically at a distance of 0.1m from the EUT and with the discharge electrode touching the coupling plane.
8.5.4. Indirect discharge for vertical coupling plane
At least 20 single discharges were applied to the center of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X 0.5m, was placed parallel to, and positioned at a distance of 0.1m from the EUT. Discharges were applied to the coupling plane, with this plane in sufficient different positions that the four faces of the EUT are completely illuminated.
8.6. Test Information
Applicant : Samson Technologies Corp EUT : Wireless Microphone UHF Transmitter/UHF WIRELESS RECEIVERM/N : AH8, AG8, CR88, CR99 Test Voltage : AC 230V/50Hz & DC 3.7V & DC 1.5V Test Engineer : Tony Test Date : 2018-03-08 Temperature : 24.1℃
Humidity : 49% Pressure : 101.7KPa Test Mode : Refer to 2.6 Required Performance : B Actual Performance : A
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 82 of 153
8.7. Test Results
Air Discharge: ±2kV ±4kV ±8kV # For Air Discharge each Point Positive 10 times and negative 10 times discharge. Contact Discharge: ±2kV ±4kV # For Contact Discharge each point positive 25 times and negative
25 times discharge For the time interval between successive single discharges an initial value of one second.
Discharge Voltage (kV)
Type of discharge
Dischargeable PointsPerformance Result
Required Observation (Pass/Fail)±2 Contact 1,2,3,4,5,6 B A Pass ±4 Contact 1,2,3,4,5,6 B A Pass ±2 Air 7 B A Pass ±4 Air 7 B A Pass ±8 Air 7 B A Pass ±2 HCP-Bottom Edge of the HCP B A Pass ±2 VCP-Front Center of the VCP B A Pass ±2 VCP-Left Center of the VCP B A Pass ±2 VCP-Back Center of the VCP B A Pass ±2 VCP-Right Center of the VCP B A Pass ±4 HCP-Bottom Edge of the HCP B A Pass ±4 VCP-Front Center of the VCP B A Pass ±4 VCP-Left Center of the VCP B A Pass ±4 VCP-Back Center of the VCP B A Pass ±4 VCP-Right Center of the VCP B A Pass
Discharge Points Description 1 Screw 2 Metal 3 DC Input Port 4 Antenna 5 BALANCED OUTPUT Port 6 UNBALANCED OUTPUT Port 7 Slot
Note:
1、There was no change compared with initial operation during the test.
Discharge was considered on Contact and Air and Horizontal Coupling Plane (HCP) and Vertical Coupling Plane (VCP).
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 83 of 153
9. RF FIELD STRENGTH SUSCEPTIBILITY TEST
9.1. Test Equipment
Equipment Manufacturer Model No. Serial No. Last Cal. Next Cal.Signal Generator R&S SML03 102460 Jan. 15,18 1 Year Amplifier A&R 150W1000M3 313157 Jan. 15,18 1 Year
Isotropic Field Probe RadiCentre CTR1008A 05D00433SNO-03 Jan. 15,18 1 Year
Log-periodic Antenna SCHWARZBECK STLP 9128E 9128E-012 Jan. 15,18 1 Year
This test was witnessed in Guangdong Dongguan Quality Supervision Testing Center.
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 84 of 153
9.2. Block Diagram of Test Setup
Frequency For 80-1000MHz
Frequency For 1.0-6.0GHz
3 Meters
EUT and Support System
Power Amp Signal Generator
PC System
Full Anechoic Chamber
80cm
3 Meters
EUT and Support System
80cm
Full Anechoic Chamber
Power Amp Signal Generator
PC System
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 85 of 153
9.3. Test Severity Level and Performance Criteria
Severity Level Test Field Strength V/m Performance Criteria
1. 1
A 2. 3
3. 10
X. Special
9.4. Operating Condition of EUT
Refer to 2.6
9.5. Test Procedure
The field sensor is placed on the EUT table (0.8 meter above the ground) which is 3 meters (for frequency range 80MHz-1GHz) and 1 meters (for 1.0GHz-6.0GHz) away from the transmitting antenna. Through the signal generator, power amplifier and transmitting antenna to produce a uniformity field strength (3V/m measured by field sensor) around the EUT table from frequency range 80MHz-1000MHz, 1.0GHz-6.0GHz and records the signal generator‘s output level at the same time for whole measured frequency range. Then, put EUT and its simulators on the EUT turn table and keep them 3 meters away from the transmitting antenna which is mounted on an antenna tower and fixes at 3 meter height above the ground. Using the recorded signal generator’s output level to measure the EUT from frequency range 80MHz-1000MHz, 1.0GHz-6.0GHz and both horizontal & vertical polarization of antenna must be set and measured. Each of the four sides of EUT must be faced this transmitting antenna and measures individually. All the scanning conditions are as follows:
Test conditions Frequency 80MHz-1GHz, 1.0GHz—6.0GHz
Frequency increments step 1% of momentary used
Test level 3V/m (unmodulated)
Dwell time 3s
Test signal 80% amplitude modulated by 1kHz sinusoidal audio signal
9.6. Test Information
Applicant : Samson Technologies Corp EUT : Wireless Microphone UHF Transmitter/UHF WIRELESS RECEIVERM/N : AH8, AG8, CR88, CR99 Test Voltage : AC 230V/50Hz & DC 3.7V & DC 1.5V Test Engineer : Tony Test Date : 2018-03-09 Temperature : 24.5℃
Humidity : 52% Pressure : 101.7KPa Test Mode : Refer to 2.6 Required Performance : A Actual Performance : A
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 86 of 153
9.7. Test Results
Modulation: AM Pulse none 1 kHz 80%
Frequency Rang :80 MHz -1000MHz
EUT vs Antenna Position
Test antenna :Horizontal Test antenna :Vertical Result
Required Observation Required Observation (Pass / Fail)
Front A A A A Pass
Right A A A A Pass
Rear A A A A Pass
Left A A A A Pass
Performance: There was no change compared with initial operation during the test.
Frequency Rang : 1.0GHz—6.0GHz
EUT vs Antenna Position
Test antenna :Horizontal Test antenna :Vertical Result
Required Observation Required Observation (Pass / Fail)
Front A A A A Pass
Right A A A A Pass
Rear A A A A Pass
Left A A A A Pass
Note:
1、There was no change compared with initial operation during the test.
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 87 of 153
10. ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
10.1. Test Equipment
Equipment Manufacturer Model No. Serial No. Last Cal. Cal. IntervalEFT Generator HAEFELY ECOMPACT 4 173659 June 17,17 1 Year Capacitive Coupling Clamp HAEFELY IP4A 181035 June 17,17 1 Year Test Software HAEFELY emv check 2000 N/A N/A N/A Calibration Lab: CEPREI Calibration and Testing Center
10.2. Block Diagram of Test Setup
+
10.3. Operating Condition of EUT
Refer to 2.6
10.4. Test Procedure The EUT and its simulators were placed on the ground reference plane and were insulated from it by a wood support 0.1m + 0.01m thick. The ground reference plane was 1m*1m metallic sheet with 0.65mm minimum thickness. This reference ground plane was project beyond the EUT by at least 0.1m on all sides and the minimum distance between EUT and all other conductive structure, except the ground plane was more than 0.5m. All cables to the EUT was placed on the wood support, cables not subject to EFT/B was routed as far as possible from the cable under test to minimize the coupling between the cables.
10.4.1. For input and AC power ports:
The EUT was connected to the power mains by using a coupling device that couples the EFT interference signal to AC power lines. Both positive transients and negative transients of test voltage were applied during compliance test and the duration of the test can’t less than 1min.
10.4.2. For signal lines and control lines ports:
Ports which are intended to be connected to telecommunication networks (e.g. public switched telecommunication networks, integrated services digital networks, local area networks and similar networks.)
10.4.3. For DC input and DC output power ports:
It’s unnecessary to test.
EUT EFT/B Tester
10cm wood
80cm
AC Mains (0.5±0.05 m)
AC Mains
Wall
>0.5m
Ground reference plane
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 88 of 153
10.5. Test Information
Applicant : Samson Technologies Corp EUT : Wireless Microphone UHF Transmitter/UHF WIRELESS RECEIVERM/N : AH8, CR88, CR99 Test Voltage : AC 230V/50Hz Test Engineer : Tony Test Date : 2018-03-08 Temperature : 24.1℃
Humidity : 49% Pressure : 101.7KPa Test Mode : Refer to 2.6.3 Required Performance : B Actual Performance : A
10.6. Test Results
Repetition Frequency : 5 kHz Burst Duration : 15ms Burst Period: 300ms
Inject Time(s): 120s Inject Method: Direct Inject Line: AC Mains □ DC Supply □ Signal:
Line Test Voltage Performance Result
Required Observation(+ ) Observation( - ) (Pass/Fail)
L 1kV B A A Pass
N 1kV B A A Pass
PE 1kV
L N 1kV B A A Pass
L PE 1kV
N PE 1kV
L N PE 1kV
Signal Line 0.5kV
Note:
1、There was no change compared with initial operation during the test.
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 89 of 153
11. SURGE TEST
11.1. Test Equipment
Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval Surge Controller
HAEFELY PSURGE8000 174034 June 17,17 1 Year
Surge Impulse Module
HAEFELY PIM100 174125 June 17,17 1 Year
Surge Coupling Network
HAEFELY PCD100 174134 June 17,17 1 Year
11.2. Block Diagram of Test Setup
11.3. Severity Levels and Performance Criterion
Severity Level Open-Circuit Test Voltage
kV 1 2 3 4 *
0.5 1.0 2.0 4.0
Special
11.4. Operating Condition of EUT
Refer to 2.6
EUT Test Generator
80cm
AC Main AC Main
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 90 of 153
11.5. Test Procedure
1) Set up the EUT and test generator as shown on Section 11.2 2) For line-to-line coupling mode, provide a 1kV 1.2/50us voltage surge (at
open-circuit condition) and 8/20us current surge to EUT selected points, and for active line / neutral lines to ground are same except test level is 2kV.
3) For testing symmetrical communication lines that are intended to be directly connected to outdoor telecommunication networks (e.g. public switched telecommunications networks (PSTN)) the 1,2/50 µs – 8/20 µs waveform may not be appropriate. Outdoor telecommunications networks typically have cable lengths in excess of 300 m and may be many kilometres in length. As a result of the nature of these networks the 10/700 µs – 5/320 µs waveform is more representative of actual surges encountered in the field. Annex A defines the testing methods and generator characteristics for testing using the 10/700 µs – 5/320 µs generator.
4) At least 5 positive and 5 negative (polarity) tests with a maximum 1/min repetition rate are applied during test.
5) Different phase angles are done individually. 6) Record the EUT operating situation during compliance test and decide the EUT
immunity criterion for above each test.
11.6. Test Information
Applicant : Samson Technologies Corp EUT : Wireless Microphone UHF Transmitter/UHF WIRELESS RECEIVER M/N : AH8, CR88, CR99 Test Voltage : AC 230V/50Hz Test Engineer : Tony Test Date : 2018-03-08 Temperature : 24.1℃
Humidity : 49% Pressure : 101.7KPa Test Mode : Refer to 2.6.3 Required Performance : B Actual Performance : A
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 91 of 153
11.7. Test Results
No.of pluse: ±5 Interval:60 Seconds
Line : AC Mains □ DC Supply □ Signal :
Location
Volt 500V 1kV 2kV Result
Phase Performance Performance Performance
(Pass/Fail) Required + - Required + - Required + -
L-N
0° B A A B A A Pass 90° B A A B A A Pass 180° B A A B A A Pass 270° B A A B A A Pass
L-PE
0° 90° 180° 270°
N-PE
0°
90°
180°
270°
LAN Port 0°
WAN Port 0°
Note:
1、There was no change compared with initial operation during the test.
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 92 of 153
12. INJECTED CURRENTS SUSCEPTIBILITY TEST
12.1. Test Equipment
Equipment Manufacturer Model No. Serial No. Last Cal. Cal. IntervalCS Test System FRANKONIA CIT-10 126A1163 June 17,17 1 Year CDN FRANKONIA CDN-M2+M3 A2210150 June 17,17 1 Year EM-Clamp FRANKONIA EMCL-20 132A1207 June 17,17 1 Year Test Software FRANKONIA EN61000-4-6 N/A N/A N/A Calibration Lab: CEPREI Calibration and Testing Center
12.2. Block Diagram of Test Setup
12.3. Severity Levels and Performance Criterion
Level Voltage Level (e.m.f.) V
1. 1
2. 3
3. 10
X Special
12.4. Operating Condition of EUT
Refer to 2.6
EUT
CDN AC Mains
SignalGenerator
PowerAmplifier
Personal Computer Control System
0.1m
AE
CDN
50Ω TERMINATOR
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 93 of 153
12.5. Test Procedure
1) Setup the EUT, CDN and test generators as shown on Section 12.2. 2) Let the EUT work in test mode and test it. 3) The EUT are placed on an insulating support 0.1m high above a ground reference
plane. CDN (coupling and decoupling device) is placed on the ground plane about 0.3m from EUT. Cables between CDN and EUT are as short as possible, and their height above the ground reference plane shall be between 30 and 50 mm (where possible).
4) The disturbance signal described below is injected to EUT through CDN. 5) The EUT operates within its operational mode(s) under intended climatic conditions
after power on. 6) The frequency range is swept from 0.150MHz to 80MHz using 3V signal level, and with
the disturbance signal 80% amplitude modulated with a 1kHz sine wave. 7) The rate of sweep shall not exceed 1.5*10-3decades/s. Where the frequency is swept
incrementally; the step size shall not exceed 1% of the start and thereafter 1% of the preceding frequency value.
8) Recording the EUT operating situation during compliance testing and decide the EUT immunity criterion.
12.6. Test Information
Applicant : Samson Technologies Corp EUT : Wireless Microphone UHF Transmitter/UHF WIRELESS RECEIVERM/N : AH8, CR88, CR99 Test Voltage : AC 230V/50Hz Test Engineer : Tony Test Date : 2018-03-08 Temperature : 24.1℃
Humidity : 49% Pressure : 101.7KPa Test Mode : Refer to 2.6.3 Required Performance : A Actual Performance : A
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 94 of 153
12.7. Test Results
Frequency Range (MHz)
Injected Position Voltage Level
(e.m.f.) Required Observation
Result
(Pass / Fail)
0.15 ~ 20 AC mains 3V A A PASS
20 ~ 80 AC mains 3V A A PASS
0.15 ~ 20
20 ~ 80
0.15 ~ 20
20 ~ 80
Modulation Signal:1kHz 80% AM
Note:
1、There was no change compared with initial operation during the test.
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 95 of 153
13. VOLTAGE DIPS AND INTERRUPTIONS TEST
13.1. Test Equipment
Equipment Manufacturer Model No. Serial No. Last Cal. Cal. IntervalMain Interference Simulator
HAEFELY ECOMPACT 4 173659 June 17,17 1 Year
Test Software HAEFELY emv check 2000 N/A N/A N/A Calibration Lab: CEPREI Calibration and Testing Center
13.2. Block Diagram of Test Setup
13.3. Operating Condition of EUT
Refer to 2.6
13.4. Test Procedure
1) The EUT and test generator were setup as shown on Section 13.2. 2) The interruptions are introduced at selected phase angles with specified duration. 3) Record any degradation of performance.
13.5. Test Information
Applicant : Samson Technologies Corp EUT : Wireless Microphone UHF Transmitter/UHF WIRELESS RECEIVER M/N : AH8, CR88, CR99 Test Voltage : AC 230V/50Hz Test Engineer : Tony Test Date : 2018-03-08 Temperature : 24.1℃
Humidity : 49% Pressure : 101.7KPa Test Mode : Refer to 2.6 Required Performance : B&C Actual Performance : C
EUT
80cm
AC Mains AC Mains Main Interference
Simulator
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 96 of 153
13.6. Test Results
Test Level
% UT
Voltage Dips & Short
Interruptions % UT
Duration (in period)
Phase Angle Required Observation Result
(Pass / Fail)
0 100 0.5P 0。
-360。
B A PASS
0 100 1P 0。
-360。
B A PASS
70 30 25P 0。
-360。
B A PASS
0 100 250P 0。
-360。
C C PASS
Note:
1、The EUT was Stopped during the test, but recoverable by user after the test.
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 97 of 153
14. PHOTOGRAPHS OF TEST SETUP
14.1. Set-up for Conducted disturbance at mains terminals test
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 98 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 99 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 100 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 101 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 102 of 153
14.2. Set-up for Radiated(30MHz-1GHz) test
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 103 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 104 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 105 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 106 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 107 of 153
14.3. Set-up for Radiated(Above 1GHz) test
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 108 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 109 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 110 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 111 of 153
14.4. Set-up for Harmonic current and Voltage fluctuations & flicker test
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 112 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 113 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 114 of 153
14.5. Set-up for Electrostatic discharge immunity test
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 115 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 116 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 117 of 153
14.6. Set-up for Electrical fast transient/burst immunity test
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 118 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 119 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 120 of 153
14.7. Set-up for Surge test
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 121 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 122 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 123 of 153
14.8. Set-up for Injected currents susceptibility test
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 124 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 125 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 126 of 153
14.9. Set-up for Voltage dips and interruptions test
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 127 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 128 of 153
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 129 of 153
15. PHOTOGRAPHS OF EUT
External Photos M/N: AH8
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 130 of 153
External Photos M/N: AH8
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 131 of 153
External Photos M/N: AH8
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 132 of 153
External Photos M/N: AG8
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 133 of 153
External Photos M/N: AG8
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 134 of 153
External Photos M/N: AG8
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 135 of 153
External Photos M/N: ATX
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 136 of 153
External Photos M/N: ATX
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 137 of 153
External Photos M/N: ATX
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 138 of 153
External Photos M/N: ATX
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 139 of 153
External Photos M/N: CR88
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 140 of 153
External Photos M/N: CR88
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 141 of 153
External Photos M/N: CR88
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 142 of 153
External Photos M/N: CR99
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 143 of 153
Internal Photos M/N: AH8
Antenna
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 144 of 153
Internal Photos M/N: AH8
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 145 of 153
Internal Photos M/N: AG8
Antenna
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 146 of 153
Internal Photos M/N: AG8
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 147 of 153
Internal Photos M/N: CR88
Antenna
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 148 of 153
Internal Photos M/N: CR88
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 149 of 153
Internal Photos M/N: CR88
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 150 of 153
Internal Photos M/N: CR99
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 151 of 153
Internal Photos M/N: CR99
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 152 of 153
Internal Photos M/N: CR99
EST Technology Co., Ltd Report No. ESTE-R1801024 Page 153 of 153
Internal Photos M/N: CR99